Loading...
BSOL2015-014478-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application Description Property Zoning: Application Valuation: Applicant: SOLARCITY CORPORATION 3055 CLEARVIEW WAY ATTN ZOE STEELE SAN MATEO, CA 94402 c&,,, 4 4v Quigraj COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 BSOL2015-0144 Owner: 52900 AVENIDA MENDOZA MARICELA MUNGUTA 773333009 52900 AVE N I DA M EN DOZA MUNGUTA / (18) ROOF MOUNTED PANELS (1) INVERTER 4.77KW LA QUINTA, CA 92253 $10,541.70 Contractor: SOLARCITY CORPORATION 3055 CLEARVIEW WAY ATTN ZOE STEELE SAN MATEO, CA 94402 (650)963-5630 Uc. No.: 888104 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Cla s: 46 B C30 A C20 L' nse : 88 104 Date- Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from th C ntractor's State License Law for the following reason (Sec. 7031.5, Business and Pro ssions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant t6 the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Addre: Date: 9/1/2015 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of he r or. which this permit is issued. I have and will maintain workers' compensation insurance, as required by Sec o 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any,manner so as to become subject to the workers' compensation laws of California, and a e tha ' I sho d come subject to the workers' compensation provisions of ec 'on 700 of t e Lab - r Code, I shall forthwith com ith � hose provisions. Date: Applican : WARNING: FAILURE TO SECURE WORKERS' COMPENSATIOOVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTI ND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITI TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinance d st ws reoup to building construct* n, and hereby authorize representative of th ty to ntehe above• mentigne p o erty for inspection purposes. Date: It;—Signature (Applicant or Ag t): � z M m� T m O M T. M M � WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of he r or. which this permit is issued. I have and will maintain workers' compensation insurance, as required by Sec o 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any,manner so as to become subject to the workers' compensation laws of California, and a e tha ' I sho d come subject to the workers' compensation provisions of ec 'on 700 of t e Lab - r Code, I shall forthwith com ith � hose provisions. Date: Applican : WARNING: FAILURE TO SECURE WORKERS' COMPENSATIOOVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTI ND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITI TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinance d st ws reoup to building construct* n, and hereby authorize representative of th ty to ntehe above• mentigne p o erty for inspection purposes. Date: It;—Signature (Applicant or Ag t): � "� " i T::DESCRIPTION" _ .. INFORMATION 4`•-ACCOUNT;j4 CITY`"p AMOUNT � PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 PAID BY . ' t t 3..• 'r4..4 METHOD �r : , ;RECEIPT # CHECK #' CLTD BY Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $1.00 $0.00 DESCRIPTION ''' z a x r a. ACCOUNT .QTY .:AMOUNT' PAID, PAID DATE PV SYSTEM - ARRAY, FIRST 20 101-0000-42403 0 $24.17 $0.00 <; P41LD BY.` . ' METHOD a;. , ^RECEIPT # CHECK# CLTD BY �'' DESCRIPTION 'ACCOUNT QTY AMOUNT'! PAID ' 'ti. PAID,DATE PV SYSTEM - ARRAY, FIRST 20 PC 101-0000-42600 0 $24.17 $0.00 PAID BY x"_' `' 3 "METHOD '-'' `' RECEIPT # '"''` CHECK # CLTD BY , Total Paid for ELECTRICAL: $48.34 $0.00 r -.DESCRIPTION � a "ACCOUNT a. QTY.. ` ' � ` -•AMOUNT � � PAID.};` .. PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 • °PAID ; BY r•< °''= METHOD RECEIPT.# LCHECK#, CLTD BY, Total Paid for PERMIT ISSUANCE: $91.85 $0.00 • �o Description: MUNGUTA / (18) ROOF MOUNTED PANELS (1) INVERTER 4.77KW Type: SOLAR Subtype: Status: APPROVED Applied: 8/21/2015 SKH Approved: 9/1/2015 LUR Parcel No: 773333009 Site Address: 52900 AVENIDA MENDOZALA QUINTA,CA 92253 Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 147 Lot: 18 Issued: UNIT 15 Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $10,541.70 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 COMPLETION DATE NOTES Details: 4.77kW SOLAR ARRAY- (18) 265W KYOCERA PANELS W/ (1) PVI -3.6 -S -US -Z -A INVERTER (319SF] 2013 CALIFORNIA ELECTRICAL CODE. FINANCIAL INFORMATION 1 Printed: Tuesday, September 01, 2015 11:35:47 AM 1 of 2 C , SYS7EM5 ADDITIONAL CHRONOLOGY TYPE "STAFF NAME. .y' • -ACTION DATE COMPLETION DATE NOTES E-MAIL LUIS URIBE 9/1/2015 9/1/2015 SENT ELENA AN EMAIL. PERMIT IS READY TO BE ISSUED PLAN CHECK SUBMITTAL STEPHANIE KHATAMI 8/21/2015 8/21/2015 RECEIVED CONDITIONS CONTACTS NAME TYPE,.: - . NAME ` _ ADDRESSI `t, CITY' STATE :" `ZIP ,PHONE,' ,- FAX.:' EMAIL'- APPLICANT SOLARCITY CORPORATION 3055 CLEARVIEW WAY SAN MATEO CA 94402 CONTRACTOR SOLARCITY CORPORATION 3055 CLEARVIEW WAY SAN MATEO CA 94402 OWNER MARICELA MUNGUTA 52900 AVENIDA LA QUINTA CA 92253 MENDOZA FINANCIAL INFORMATION 1 Printed: Tuesday, September 01, 2015 11:35:47 AM 1 of 2 C , SYS7EM5 DESCRIPTION ACCOUNT = QTY 3AMOUNT PAID PAID DATE 77 RECEIPT # CHECK # ; ' METHOD PAID CLTD f „ : BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $1.00 $0.00 BSA: PV SYSTEM - ARRAY, 101-0000-42403 0 $24.17 $0.00 FIRST 20 PV SYSTEM - ARRAY, 101-0000-42600 0 $24.17 $0.00 FIRST 20 PC Total Paid for ELECTRICAL: $48.34 $0.00 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:• •• INSPECTIONS SEQID ; INSPECTION TYPE'. , ;,INSPECTOR SCHEDULED COMPLETED • RESULT wr REMARKS .:• NOTES :; , s"-, ; ,_- DATE`_ DATE k; .. SOLAR FINAL" BLD PARENT PROJECTS BOND INFORMATION .'ATTACHMENTS: ' Printed: Tuesday, September 01, 2015 11:35:47 AM 2 of 2 C SYSTEMS Bina City of La Quanta Btdkgng 8r Safety DhWon P.O Box 1504,78-495 Calle Tamptco 1.a.Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address Owner's Name:. i A P. Number. Address:. . Legal Description: city, ST, zip: La Quinta, CA Contractor Solar City Telephone:_;1 31 P,9 ProjectDeskxiption: roof mountedsolar panels . Address: 3055 Clearview Way. city, $T, zap: San Mateo, CA, 94402 inverter(s)' Telephone: 650-638-1028 state Lia # : 888104 City Lie',#; Arch, FaW., Designer Address: City, ST, Zip: Telephone: State Lia #: Name of contact Person: Elena Loya Construction Type:. occupancy: Project type (circle one): New Add'n Alter Repair Demo Sq. FL: # ries~ # Uait� Telephone # of Contact Person: (442)256-1134 Estimated value of Proj APPLICANT: DO NOT wRITE BELOw THIS UNE # Submittal Revd Reed TRACIKIIVG PERMIT FETE Plan Sets Plan Cheek submitted Item Amount Structural Cafes. Reviewed, ready for corrections Plan Cheek Deposit. . Trust Coles. Called Contact Person Plan Check Ralanee ZYtie 24 Calcs. Pians picked up Construction ' 'Flood plain plan Pians resubmitted.'. Mechanical Grading plan Z'! Review, ready for correctionsfttsue Electrical Subeontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN txouSE:- ud Review; ready for cormetionvinuc Developer Impact Fee Planning Approval- Called Contact Person A.LP.P. Pub. Wks. Appr ' Date of permit Issue School Fees Total Permit Fees ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A ALL CONSTRUCTION SHAUL COMPLY WITH THE 2013 AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. CALIFORNIA BUILDING, RESIDENTIAL, MECHANICAL, BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. ELECTRICAL, PLUMBING,NERGY, AND GREEN CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING BUILDING CODES AND THF LA QUINTA MUNICIPAL DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN CODE EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL S Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). CITY OF LA QUINTA 0 1 Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING SAFETY DEPT. kVA KILOVOLT AMPERE kW KILOWATT BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC ����®��� LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). FOR CONSTRUCTION MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW NEUT NEUTRAL RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY717 UL LISTING. DATE C/ / BY NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE POI POINT OF INTERCONNECTION MANUFACTURER USING UL LISTED GROUNDING HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. `• S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES PV5 THREE LINE DIAGRAM PV6 ELECTRICAL CALCULATIONS CA888104 #CALIFORNIA 1. ALL WORK TO BE DONE TO THE 2013 PV8 THREE LINE DIAGRAM Cutsheets Attached C-10 BUILDING CODE AND THE 2013 CALIFORNIA RESIDENTIAL CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY - THE 2013 CALIFORNIA ELECTRIC CODE. �' O MODULE GROUNDING METHOD: ZEP SOLAR • �' AHJ: La QUIntO REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: Imperial Irrigation District # # # # # # # # CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER JB CONTAINED SHALL NOT E USED FOR THE OF ANYONE EXCEPT SOLARgTY INC., MOUNTING SYS EM:NOR -9224259 00 OM- MUNGUTA MARCELA DESCRIPTION: MUNGUTA RESIDENCE DESf;r! Bhanu Swaroop Gaddum SolarCity.BENEIIT v� SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 52900 AVENIDA MENDOZA 4.77 KW PV ARRAY►r PART TO 01HERS OUTSIDE THE RECIPIENTS Moouus ORGANIZATION, EXCEPT IN CONNECTION WITH LA QUINTA CA 92253 , THE SALE AND USE OF THE RESPECTIVE (18) KYOCERA # KU2656ZPA APN: 773333009 SOLARCITY EQUIPMENT, WITHOUT THE WRIIIENN PAGE NAME:T: 3055 gearvieN Way SHEET: REV'. DATE: Son Mateo, CA 94402 INVERTER: PERMISSION of solARaTY INC ABB PVI-3.6—OUTD—S—US—Z—A (760) 218-1363 COVER SHEET (650) 636-1028 F:(650) 638-1029 PV 1 8/20/2015 (666>-soL-an (765-2489) .w..edarcIty., ar o O (E) UTILITY METER & WARNING LABEL CONFIDENTIAL — THE INFORMATION HEREIN N A' CONTAINED SHALL NOT BE USED FOR THE O MOUNTING SYSTEM: BENEFIT OF ANYONE EXCEPT SOLARCITY INC., .r NOR SHALL IT BE DISCLOSED IN WHOLE OR IN _ ZEP Mighty Hook LG LOAD CENTER & WARNING LABELS C MODULES (18) KYOCERA # KU2656ZPA ?s ORGANIZATION, EXCEPT IN CONNECTION NTH THE SALE AND USE OF THE RESPECTIVE N SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: CONDUIT RUN ON INTERIOR a (E) DRIVEWAY 0 L i TRANSFORMER INFORMATION: KVA PHASE HIGH KV LOW 120/240V –METER#1B4SR-134767 "PROPOSED BI–DIRECTIONAL METER#1BSR-134767" Culter–Hammer #DG221URB – AC DISCONNECT:30A, 240Vac, Non–Fusible, NEMA 3R OFT FROM MAIN PANEL Front Of House tiL� O & SABFY pC ' T. ��� FOG�UGTION qzl A � f1 _ 3' FSB ml 0 0 0 0 0 to U_ I I MI 0 0 0 0 0 I Iw 0 I„ IW I 0 0 0 0 o ��I I C 0 `. M CL G) o, N a MUNGUTA, MARCELA 52900 AVENIDA MENDOZA LA QUINTA, CA 92253 (760) 218-1363 200A,` 24OV, SINGLE PHI 2 WIRES, 22kAiC EXISTING BI DIRECTIONAL METER#1B4SR-134767 DESMPTION: MUNGUTA RESIDENCE 4.77 KW PV ARRAY PAGE NAME SITE PLAN 0 PITCH: 20 ARRAY PITCH: 20 MPl IAZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Low Profile W -Tile STORY: 1 S1 I FrFNn O (E) UTILITY METER & WARNING LABEL CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER J[3-9224259 0 0 A' CONTAINED SHALL NOT BE USED FOR THE MOUNTING SYSTEM: BENEFIT OF ANYONE EXCEPT SOLARCITY INC., .r NOR SHALL IT BE DISCLOSED IN WHOLE OR IN _ ZEP Mighty Hook LG LOAD CENTER & WARNING LABELS PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES (18) KYOCERA # KU2656ZPA ?s ORGANIZATION, EXCEPT IN CONNECTION NTH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: CONDUIT RUN ON INTERIOR PERMISSION OF SOLARCITY INC. ABB # PVI-3.6–OUTD–S–US–Z–A � f1 _ 3' FSB ml 0 0 0 0 0 to U_ I I MI 0 0 0 0 0 I Iw 0 I„ IW I 0 0 0 0 o ��I I C 0 `. M CL G) o, N a MUNGUTA, MARCELA 52900 AVENIDA MENDOZA LA QUINTA, CA 92253 (760) 218-1363 200A,` 24OV, SINGLE PHI 2 WIRES, 22kAiC EXISTING BI DIRECTIONAL METER#1B4SR-134767 DESMPTION: MUNGUTA RESIDENCE 4.77 KW PV ARRAY PAGE NAME SITE PLAN 0 PITCH: 20 ARRAY PITCH: 20 MPl IAZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Low Profile W -Tile STORY: 1 S1 I FrFNn O (E) UTILITY METER & WARNING LABEL ln� INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © DC DISCONNECT & WARNING LABELS LEM AC DISCONNECT & WARNING LABELS DC JUNCTION/COMBINER BOX & LABELS QD DISTRIBUTION PANEL & LABELS LG LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR — GATE/FENCE Q HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED SITE PLAN N Scale: 1/8" = 1' IN E 0 1' 8' 16' S DESIGN: Bhonu Swaroop Gaddum ;\SolarCity. 3055 Cleardew Way San Mateo, CA 94402 T:(650) 638-1026 F:(650) 638-1029 (688)—SOL—CITY (765-2489) www.solarcity.com — — - SHEET: REtk DATE PV 2 8/20/2015 A SIDE VIEW OF MPI- NTS MPI X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER -NOTES LANDSCAPE 48" 24" 52" 52" 24" 24" PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC ROOF AZI ARRAY AZI 180 PITCH 20 STORIES: 1 180 PITCH 20 Low Profile W -Tile CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER JB -9224259 0 0 CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES:- ODULES:THE THESALE AND USE OF THE RESPECTIVE (18) KYOCERA # KU2656ZPA SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF SOLARCITY INC. ABB # PVI-3.6-OUTD-S-US-Z-A ZEP SPANNER BAR -� " DIA BOLT & NUT — ZEP SPANNER BAR CLAMP STANDOFF (E) TILE � _ (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG BOLT %,(2-1/2- EMBED, MIN) (E) RAFTER e REMISE OWNER: DESCRIPTION: MUNGUTA, MARCELA 52900 AVENIDA MENDOZA !' LA QUINTA, CA 92253 (760) 218-1363 ._ (6) uu �uu (5) 57(4) LOWEST MODULE SUBSEQUENT MODULES S1STANDOFF Scale: 1 1/2" = 1' MUNGUTA RESIDENCE 4.77 KW PV ARRAY PAGE NAME STRUCTURAL VIEWS INSTALLATION ORDER LOCATE RAFTER, MARK RAFTER LOCATION, AND REMOVE TILE. (1) PLACE STANDOFF BASE & DRILL PILOT HOLES AT THE RAFTER LOCATION. 2) CLEAN PAPER AROUND PILOT HOLE. 3) ADJUST STANDOFF TO BATTEN HEIGHT. SEAL PILOT HOLES AND BOTTOM (4) OF STANDOFF WITH POLYURETHANE SEALANT. 5) LAG STANDOFF INTO RAFTER. 6) NOTCH TILE WEATHERING TO FIT AROUND STANDOFF. 7) REINSTALL TILE. DESIGN: Bhanu Swaroop Gaddum ',;`Solaruty. 3055 aeaMew Way SHEET: REV. DATE San Mateo, CA 944M T:(650) 638-1028 F:(650) &3&-1029 PV 3 8/20/2015 1 (888) -SOL -Cm (765-2489) www.saarclty.com „.r GROUND SPECS . MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE OND (N) #8 GEC TO (E) LIFER AT PANEL Panel Number: SC204OM20OF Inv 1: DC Ungrounded INV 1 - (1) ABB # PVI-3.6-OUTD-S-US-Z-A LABEL: A - (18) KYOCERA # KU2656ZPA • CA # 888104 WITH IRREVERSIBLE CRIMP Meter Number: 1B4SR-134767 FCI Inverter; Zigbee 360OW, 240V, 96% PV Module; 265W, 238.1W PTC, 40MM, Blk Frm, H4, ZEP, 1000V, Blk Cell, io Backbar C-10 INV 2 Underground Service Entrance Voc: 38.3 Vpmax: 31 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E� 20OA/2P MAIN CIRCUIT BREAKER A MAIN SERVICE PANEL E200 ADJUST MIN. ACTIVATION VOLTAGES! CUTLER—HAMMER Inverter 1 IND 1 200A/2P Disconnect 3 ABB Oc+ VStart = 200V PVI-3.6—OUTD—S—US—Z—A DC- MP1:1X9 (E) LOADS A • Ll F _ EGC——————--———— — ----j ' DEGcC+ II 2P GND-------------------------------------- N EGG Dc- 1 V20A/VStart=200 Dc+DC+ ---- II -E� DG G MP1: 1x9 -. (1) Conduit Kit; 3/4' EMT N I EGCIGEC —j - zZ --— — _ - - -- _ - ca GEC — — --- -- TO 120/240V � I - CIS C)F 1 A QUI SINGLE PHASE UTILITY SERVICE I NTA BUILDING & SAFETY DEPT. ` @`�� yG q APPROVED �% PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE FOR CONSTRUCTION PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF GROUPING SHALL BE WIRE TIES OR SIMILAR MEANS AT LEAST DA �_BY ONCE, AND THEN AT INTERVALS NOT TO EXCEED SIX (6) FEET. '_'PHOYOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONS INDICATE IF THE COMBINING PROCESS TAKES PLACE IN THE :INVERTER. Voc* = MAX VOC AT MIN TEMP f `_ Poj (1)SQUARE D & H 14220 PV BACKFEED BREAKER Breaker, A 2P, 2 Spaces A (1)CUTLER—HAMMER ® DC221UR8 /� C A Disconnect; 30A, 24OVac, Non—Fusible, NEMA 3R DC' — (1)CUTLER—{1AMMER& DG03ONB Ground/Neutral It; 30A, General Duty (DG) O (1)AWG 810, THWN-2, Block (1) AWG ®10, THWN-2, Red (2)AWG #10, PV wire, 600V, Black Voc* = 388.13 VDC Isc = 9.26 ADC O (1) AWG ®10, THHN/THWN-2, Green EGC VmP =279 VDC Imp= 8.55 ADC . , • • , (1)AWG g10, THWN-2, White — (1)AWG #8, THWN-2, Green , NEUTRAL Vmp =240 VAC Imp=16 AAC FPC/GEC.- (1) Conduit. Kit;. 3/4'.EMT......... , . 1 ConduitKit; 3/j'. EMT (Y AWG 810, PV Wfre, 600V, Black Voc* _ 38613 VDC Isc = 9.26 ADC O (1)AWG THHN/THWN-2, Green EGC VmP — 279 VDC Imp= 8.55 ADC ®10, ... _ . • .. (1)Conduit Kit; 3/4' EMT CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., JB -9224259 0 0 PREMISE OWNER. DESCRIPTION: MUNGUTA MARCELA MUNGUTA RESIDENCE ' DESIGN: Bhanu Swaroop Gaddam `N�}s } �.O �1SolarC�ty. TEM: NO SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS hty Hook [INESR 52900 AVENIDA MENDOZA 4.77 KW PV ARRAY LA QUINTA, CA 92253 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clearview Way San Mateo, F: 94402 50) 10lycom THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN OCERA # KU2656ZPA PAGE NAME SHEET: REV: DATE PERMISSION OF SOLARCITY INC. PVI=3.6-OUTD-S-US-Z-A (760) 218-1363 THREE LINE DIAGRAM PV 5 8/20/2015 (888j-s��an 7658-2489) www ol ELECTRICAL CALCULATIONS QUINT CIV®� DEPT• �uILDita �\j F -D RUG��ON Q CON j -TRU BY pATE�� Module: Inverter 1: Module: 18 Kyocera 265W 1000V 238.1 Inv Power WPTC Voltage Drop Calculations Version 5.8.0 Vdrop = (imp)" 2 * Length) Resistance / Vmp) Im A Max. Length ftWire String: 8.55 75 AWG #10 at Max Ave Hi: 109 deg F Vdrop = 8.55 150 0.00124 Ohms / 235.06 0.68 Branch: 8.55 0 AWG #10 at Max Ave Hi: 109 deg F Vdrop = (8.55 0 0.00124 Ohms) / 279 0 Total voltage dro in DC conductors = 0.68 Inverter: 16 15 1 AWG #10 at 240V Vdrop = 16 30 0.00124 Ohms / 240 V 0.13 Combinedi at 240V Vdrop = Ohms) / 240 V 7-1 Total voltage drop in AC conductors = 0.13 Total voltage drop in AC and DC conductors = 0 1 ABB PVI -3.6-S AFCI 0.96 3840 4114.37 Kyocera 265W 1000V 238.1 Inverter 2: Module: K ocera 265W 1000V 238.1 Inverter 3: Module: Kyocera 265W 1000V 238.1 Inverter 4: Total: 18 Modules Total Inv Pwr: 3840 14114.37 PTC Photovoltaic Module Electrical Specifications: Total STC:I 4770 Voc: 38.3 V deg F deg C Vmp: 31 V Record Low Temp: 14 -10 Isc: 9.26 A Max Average Hi Temp: 109 43 Imp: 8.55 A Record Hi Temp: Tvoc: -0.14 V/deg C Tisc:l 5.56 1 mA/deg C String Type A and 2 Combined Strings Type A Voc Correction Method: Voc Correction Factor: ABB PVI 3.6 S AFCI Inverter Min Vdc Input: 9 Kyocera 265W 1000VI Min Vmp at Max Temp: Voc= 344.7 Vmp= 279 Max Voc at Min Temp: Isc= 9.26 Inverter Max Vdc Input: Imp= 8.55 Max String Size: lcont=l 11.58 Art 690.8(A)(1) 1 -way wire length: Manuf TVoc Data Branch Circuit Type A 1 way wire length: 0 1 strings per branch 1 1 strings per branch 2 SI P SI 9 modules per series string 91M dules per series string Voc= 344.7 V Voc= 344.7 V Vmp= 279 V Vmp= 279 V Isc= 9.26 A Isc= 9.26 A Imp= 8.55 A Imp= 8.55 A Icont= 11.58 A (cont= 11.58 A Art 690.8(A)(1) 130 235.06 388.13 600 13 0 1.a Conductor: 1 AWG #10 PV Wire Icont * 1.25 = (Amps) 14.47 30 deg C ampacity = 401 2.a Conductor 1: 1 AWG #10 Conductor 2: 1 AWG #10 Icont * 1.25 = (Amps) 30 deg C ampacity = Conductor 1 Conductor 2 14.471 14.47 401 40 1.b Icont= (Amps) Start ampacity Temperature derate (%=F) Conduit fill derate (%=#) Derated ampacity 11.58 40 0.41 1 16.4 2.b Icont= (Amps) Start ampacity Temperature derate (%=F) Conduit fill derate (%_#) Derated ampacity 11.58 11.58 1 40 40 0.41 0.41 0.8 0.8 1.0 (cont' 1.25 = (Amps) 14.47 Ampacity 40 13.12 13.121 2.c Term 1 Term 2 Temp table 90 °C:Tab 2gjjE Bap.15(B)(16) Icont'1.25= (Amps) 14.47 14.47 Ampacity 40 40 1.d 1.d Icont' 1.25 = (Amps) OCP Size = 14.47 15 Inverter Type A Output ABB PVI 3.6 S AFCI 1 way wire length: 15 ft Icont = 16 A Art 690.8(A)(1) 2.d OCP Size = 15 15 Combined Inverter Output Service Voltage= Total Inverter Power- 1 way wire length= 15 Icont = # of inverters*max inverter current Art 690.8(A)(1) Icont = (Amps) 3.a Icont * 1.25 (Amps) OCP Size = 20 Art 690.8(B)(1) Art 240.6(A) 20 3.b Conductor: AWG #10 Icont * 1.25 = (Amps) 30 deg C ampacity = THWN-2 at 90 deg C: Table 310.16 20 40 4.a Icont*1.25 = (Amps) OCP size 20 Art 690.8(B)(1) Art 240.6(A) 1 201 4.b Conductor: AWG #10 Icont * 1.25 = (Amps) 30 deg C ampacity = THWN-2 at 90 deg C: Table 310.16 20 40 3.c Icont = (Amps) Start ampacity Temperature derate (%=F) Conduit fill derate (%=#) Derated ampacity 16 40 0.91 4.c Icont = (Amps) Start ampacity° - Temperature derate (/o -F) Conduit fill derate (%=#) Derated ampacity 16 1 40 36.4 0.91 3.d Icont * 1.25 = (Amps) 20 Ampacity 35 1 36.4 4.d Icont * 1.25 = (Amps) Ampacity 20 35 CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART IZ OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE PERRMISSIONCITY EOFISOLARCITY TOUT THE WRITTEN JOB NUMBER J B-9224259 PREMISE OTS: DESCRIPTION: MUNGUTA, MARCELA MUNGUTA RESIDENCE 52900 AVENIDA MENDOZA 4.77 KW PV ARRAYi. LA QUINTA, CA 92253 PACE NAME 760 218-1363 ) ELECTRICAL CALCULATIONS DESIGN: Bhanu Sworoop Gaddam ■ � I r. �;,`�OI���I�" MOUNTING SYSTEM: ZEP Ml9nty Hook ,_ MODULES: (18) KYOCERA # KU2656ZPA _ 3055 georvieM Way Son Mateo, CA 94402 29 (868) (SOL OTY ((765-248650) 638-1028 9)�iww.solar10tycorn SHEET: REV. DATE: PV 6 8/20/2015 [INVERTER.- ABB PVI-3.6-0UTD-S-US-Z-A it CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 52900 Avenida Mendoza AC DISCONNECT UTILITY SERVICE I INVERTER AND DC DISCONNECT r--------------------------� SOLAR- PHOTOVOLTAIC ARRAYS) PHOTOVOLTAIC BACK -FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB -9224259-00 PREMISE OWNER DESCRIPTION: MUNGUTA, MARCELA r MUNGUTA RESIDENCE 52900 AVENIDA MENDOZA 4.77 KW PV ARRAY LA QUINTA, CA 92253 PAGE NAME (760) 218-1363 'SITE PLAN PLACARD Q(j/' "0R O®� ®SPT. DgTE ��°�Ucri \ey _. CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: JB -9224259 0 0 CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook PART TO OTHERS OUTSIDE THE RECIPIENTS SHEET: REV6 DATE ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE MODULES (18) KYOCERA # KU2656ZPA SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER• PERMISSION OF SOLARCITY INC. ABB # PVI-3.6—OUTD—S—US—Z—A PREMISE OWNER DESCRIPTION: MUNGUTA, MARCELA r MUNGUTA RESIDENCE 52900 AVENIDA MENDOZA 4.77 KW PV ARRAY LA QUINTA, CA 92253 PAGE NAME (760) 218-1363 'SITE PLAN PLACARD Q(j/' "0R O®� ®SPT. DgTE ��°�Ucri \ey _. DESIM: Bhanu Swaroop Gaddum �t, cilty 3055 Clearview Way SHEET: REV6 DATE San Mateo, CA 94402 T:(650) 638-1026 F:(650) 638-1029 PV 7 8/20/2015 (668)—SOL—aTY (765-2489) www.SalaraHy.aam EXISTING ELECTRICAL SERVICE ENTRANCE AND LOAD CENTER 200A 240V 10 200A MAIN BREAKER 200A/2P 20A/2P TO 120/240V SINGLE PHASE )TILITY SERVICE f PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH CUTLER HAMMER # DG221URB 30A, 240VAC ELECTRICAL ONE LINE DIAGRAM AC DC 3600 WATT UTILITY INTERACTIVE INVERTER 230 TO 600 VDC TO 120 /240 VAC 10 ABB # PVI-3.6—OUTD—S—US—Z—A V C3— (1) AWG #10, THWN-2 Black (1) AWG #10, THWN-2, White, NEUTRAL (1) AWG #8, THWN-2, Green, EGC 1 Conduit Kit; 3/4" EMT 1 AWG #10, THWN-2 Black • Vmp = 240 VAC • Imp = 16 AAC (1) Conduit Kit; 3/4" EMT 9 MODULES 2040 WATT PHOTOVOLTAIC ARRAY #1 9 MODULES 2040 WATT PHOTOVOLTAIC ARRAY #2 1 (2) AWG #10, PV WIRE, Black (1) Conduit Kit; 3/4" EMT (1) AWG #10, THWN-2, Green EGC 2 (2) AWG #10, PV WIRE, Black (1) Conduit Kit; 3/4" EMT (1) AWG #10, THWN-2, Green EGC CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER: JB -9224259 00 YKtNXUMM ""` ""` MUNGUTA, MARCELA MUNGUTA RESIDENCE Bhanu Swaroop Gaddum ���! ■ } INC., NOR SHALL IT BE DISCLOSED IN WHOLE aR IN NORBENEnTSH OF ANYONE EXCEPT IN WHOLE 52900 AVENIDA MENDOZA 4.77 KW PV ARRAY .,; y® /,`�OI���I�" MOUNTING SYSTEM: ZEP Mighty Hook _. _ ., PART TO OTHERS OUTSIDE THE RECIPIENTS L-A QUINTA CA 92253 MoOu�s — ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE.OF THE RESPECTIVE (18) KYOCERA # KU2656ZPA , _ — -�; 3055 CleaMew Way Sen Mateo, CA 94402 DATE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. PAGE NAME 760 218-1363 � ) THREE LINE DIAGRAM _ - PV 8 8/20/2015 T.(650) 638-1028 F:(650) 638-1029 . (688)—SOL—CITY (765-2489) www.solarcity.com INVERTER:. ABB PVI-3.6—OUTD—S—US—Z—A Label Location: Label Location: ";� Label Location: (C)(IC)(CB)(AC) '- (DC)(INV)(CB)SYSTEM Per Code: DISCONNECT . • - - ELECTRIC • ■ Per Code: CRC R331.2 •' • ■ CONDUCTORS CK • CEC 690.35(F) THIS Label Location: PHOTOVOLTAIC SYSTEM ARE -TO BE USED,WHEN , PH • • • ' (DC) (INV)`' -• ■ ■ 'MAY BE INVERTERS - » DISCONNECT Per Code: F` ENERGIZED UNGROUNDED � •T M CEC 690.14.C.2 - - Label Location: -WARNING (DC) .-•, , Per Code: .;; r^ELECTRIC f Label Location: . • NOT TOUCSHOCK HAZARD CEC 690.17 a3 MAXIMUM-• - (DC) (INV) • : • ■ .� • • . LOAD . ENERGIZEDPer Code:, •. .• POWERMAXIMUM - POINT GE rnp)CEC 690.53 MAXIMUM SYSTEM= VOLTAGE #r f S n y • SHORT-CIRCUIT= r ` • �` - - r For C—�� ,� -r . -� ', " f .. : y "- Label Location: .w• v - > • J AR(POI)- - Per Code:INVERTER i - - j.• •-UT CEC 705.12.D.7 _ ' Label Location: ■ • • • {Y WARNING(DC) (CB) ;: CITY O I� C U(�1- DEVICE BUIL®IIV A SHOCKELECTRICAL -. Per Code: _ 'r� 4 Ca &SAFETY ■• • • CEC 690.17TERMINALS ON BOTH LINE AND . A PPR®VLOAD SIDES MAY BE ENERGIZED UFPT.. FOR IN THE • - POSITION - Label Location: _ ` . s- �' ; CCM�� RUCTION - DATE • PHOTOVOLTAIC -• • (POI) ALWAYSPRESENTWARNING: ELECTRICPer Code: ' y SOLARMODULESSHOCK CEC 690'17xEXPOSED • CEC 690.54; TERMINALS ON * :• ■ ••■ ■ a MAY BE ENERGIZED IN THE OPEN POSITION. FOR 4 Label Location: _ . : • SERVICE• • ,; ,k , . _ WARNING(INV) ■ PV POWER SOURCEt _ _ Per Code: MAXIMUM AC = - •IF A . SHOCKELECTRIC LT IS■HAZARD ■ CEC 690.5(C) OPERATING NORMALLY GROUNDED V c• MAXIMUMAC CONDUCTORS MAY BE OPERATING • • r� • UNGROUNDED AND ENERGIZED , Label Location Label Location - (D) (POI)I {' , ` • • • (AC) (POI) = Per Code: _ - (AC): AC Disconnect • Per Code: r PHOTOVOLTAIC CIRCUIT IS ■ CEC 690.64.8A - r . (C): ConduitDISC^ Y CEC 690.14.C.2 k f r': i (CB): Combiner Box t .z gz ` • (D): Distribution Panel (DC): DC Disconnect r " - :„ t (IC): Interior Run Conduit Label Location: Label Location: �,� (INV): Inverter With Integrated DC Disconnect MAXIMUM AC A (AC) (POI) • (POI) (LC): Load Center • • - Per Code: DUAL POWER _• Per Code: ps (M): Utility Meter. MAXIMUM AC CEC 690.54 • ■ • CEC 705.12.D.7 OPERATING • PHOTOVOLTAIC [!'s"� � (POI): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR ' : s . •— �- ' 3055 Clearview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED ' tt r r t • �•�, - San Mateo, CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, Label Set° T:(6S0) 638-1028 F:(650) 638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE r' ' x '�" i- • �/� (888)-CLTY (765-2489) wwwsolardty.can SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. _" SO* t o This family of single-phase string inverters complements the typical number of rooftop solar panels enabling home -owners to get the most efficient energy harvesting for the size of the property. This inverter offers a dual input section that processes two strings with independent Multiple Power Point Tracking (MPPT). This is especially useful for rooftop installations with two different orientations from two sub -arrays oriented in different directions. (For example: East and West) The dual input sections with independent MPPT enable a more optimal energy harvesting condition. The high-speed MPPT offers real- time power tracking and improved energy harvesting. The flat efficiency curve ensures high efficiency at all output levels allowing a consistent and stable performance across the entire input voltage and output power range. The transformerless operation gives the highest efficiency of up to 97.0%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size. This rugged outdoor inverter has been designed to be a completely sealed unit able to withstand the harshest environmental conditions. Highlights: — Single phase and split phase output grid connection. — Wide input range for increased stringing flexibility. — The high speed and precise MPPT algorithm offers real time power tracking and improved energy harvesting. — Outdoor NEMA 4X rated enclosure for unrestricted use under any environmental conditions. — Integrated DC disconnect switch in compliance with international Standards (-S Version). Power and productivity „ 11 ,N for abetter world[" P%1919 Additional highlights: — RS -485 communication interface (for connection to laptop or data logger). — Integrated Arc Fault Detection and Interruption (-A Version). Technical data and types 2 ABB Solar Inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD 4= II. So'larCity ZepSolar Next -Level PV Mounting Technology _ • •SoiarCity ZepSolar Next -Level PV Mounting Technology • ZS Span Components , ® - - for concrete the roofs 1x 3x 4x Spanner Bar V . "Zep Groove, - .&amFooi jy,.+ ; t .K _ Part Nos. • 4 850-1400.4X 580-1399 - 3x • a _ '8501398-tx' fi• r n .rr } • L L)O u - • Ground Y > - . - . t 4.,•�, ) � SpannerClampi.- t -; s #�f _ �.r • _ c _ . ,. ; t ... , .: ` .- Y " — 1 • Array Skirt- _ �L.— V, t, i SPlie Kit ' Spanner Clam P r• _ Part No. 850-1401, Part No. 850-1194 • t � `� w r,•.w _ Listed to UC 2703 Listed to UL 2703 . 1 -. • Corner Cap.:. _. Intertock- -. Adjustable Mighty Hook- - _ max. `.� r ;;• + .- - Y . as .-. .- - ... , _ f y. S�•x a. c -y t� _ _ r.� _ _ - «F ;Description ' - .. ' �1 4 U"'�``a PV mounting solution for concrete tile roofs + ' ~FA m Works with all Zep Compatible Modules v : . r - OWNr g r �,;;§ i t I Auto bonding UL -listed hardware creates structural and electrical bond r - Zep System has a UL 1703 Class 'A" Fire Rating when installed using modules from any manufacturer certified as "Type 1" or "Type 2" •" r �' r ' Mighty Hook V2, HDG Interlock Cam Foot IIL LISTED SpecificationsPart No. 850-1461 • Part No. 850-1388 Part No. 850-1413 c � Listed to UL 2703 Listed to UL 2703 Listed to UC2703 - Designed for pitch roofs F, - ` E11� Installs in portrait and landscape orientations - - t Zep System supports module wind uplift and snow -load pressures to 50 psf per UL 1703 ^' �' f .• - t J 1 • . Wind tunnel report to ASCE 7-05 and 7-10 standards w , Zep System grounding products are UL listed to UL'2703 and ETL listed to UL 467 ' Zep System bonding products are UL listed to UL 2703 ' Engineered for spans up to 72" and cantilevers up to 24" } a Zep wire management products listed to UL 1565 for wire positioning devices. ^ Attachment method UL listed to UL•2582 for Wind Driven Rain - e};� 'Ground Zep Array Skirt, -Grip, End Caps DC Wire Clip • . - - Part No. 850-1172 Part Nos. 850-0113,850-1421, Part No. 850-1448 , ETL listed to UL 467 850-1460, 850-1467 Listed to UL 1565 zepsolar.com ' , zepsolaccom Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services. Zap Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zap Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely each producL The end-user documentation shipped with Zep Solaris products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. ` Document # 800-1730.001 Rev A - i Date last exported: April 20, 2015 2:14 PMa ..Document # 800-1730-001 Rev A.... Date last exported: April 20, 2015 2:14 PM - 1 CUTTING EDGE TECHNOLOGY As a pioneer with four decades of experience in the development of photovoltaic systems, Kyocera drives the market as a leading provider of PV products. We demonstrate our Kaizen philosophy, or commitment to continuous improvement, by setting the industry standard in the innovation of best -in -class solar energy equipment. I QUALITY BUILT IN • UV -stabilized, anodized aluminum frame in black • Supported by major mounting structure manufacturers • Easily accessible grounding points on all four corners for fast installation • Proven junction box technology with 12 AWG PV wire works with transformerless inverters • Amphenol H4-UTX locking plug-in connectors provide safe, quick connections PROVEN RELIABILITY • Kyocera modules confirmed by the Desert Knowledge Australia Solar Centre to have the highest average output of any crystalline module • First module manufacturer in the world to pass long- term sequential testing performed by TUV Rheinland • Only module manufacturer to achieve the rank of "Performance Leader" in all six categories of GTM Research's 2014 PV Module Reliability Scorecard CERTIFICATIONS • UL1703 Certified and Registered, UL Module Fire Performance: Type 2, CEC • NEC 2008 Compliant, IEC 6121561730, and ISO 14001 DOI.` C UL US - DMPP KU -60 1000V Z Series KU265-6ZPA ELECTRICAL SPECIFICATIONS Standard Test Conditions r0 r P 265 W V 31.0 V 8.55 A 11 1 V. 38.3 V II'< 9.26 _ A p wngn<a +5/-0 % Nominal Operating Cell Temperature Conditions (NOCT) NOCT=800 , T. 45 °C Pee- 191 W V� 27.9 V l 6.85 A IV- 35.1 V - 7.49 A [PTC 238.1 W Temperature Coefficients P -0.45 %r�C V.r. -0.48 %(°C EIS 0.02 %j°C - V -0.36 %/°C lh� _ 0.06 %'°C Operating Temp -40 to +90 °C System Design I Series Fuse Rating 111 1 15A 1 Maximum DC System Voltage (UL) 1000V Hailstone Impact in (25mm) @ 51 mp (23m/s) , 'Subject to simulator measurement uncertainty of +I- 3%. KYOCERA reserves the right to modify these specifications without notice. WARNING: Read the instruction manual in its entirety prior to handling, installing & operat- ing Kyocera Solar modules. 040215 KU -60 1000V Series MODULE CHARACTERISTICS Cells per module: 60 (6 x 10) Dimensions. 65.43ini38.98ini 1.57in length/width/height (1662mm/990mm/40mm) Weight 45.2lbs (20.5kg) PACKAGING SPECIFICATIONS Modules per pallet 20 Pallets per 53' container. 36 Pallet box dimensions: 66ini40ini43in length/width/height (1 675mm/ 1005mm/ 1 055mm) Pallet box weight: 1015lbs (460kg) Grounding Hole Sl°tted •auntim We 0.16- (4a0 0.35"4.47" (gmxlamd FRAME CROSS SECTION DIAGRAM aa• uaam 1.m-asw LONGIMT SIDE OUR VALUED PARTNER { { DI ID O I I U u ' 6.81 [173] 6.36 [162] 1 .34 (9) O 5.73 [1a5] ID O I I U 6.89 [175] • 6.81 [173] 6.36 [162] 1 .34 (9) 5.73 [1a5] MT_N ON O O C ✓ u N O 0 ' O o ® OFF ® O CONCENTRIC KNOCKOUTS FOR TANGENTIAL KNOCKOUTS FOR m1/2, 3/4 CONDUIT 1/2, 3/4 CONDUIT n n ri in QUANTITY 2 QUANTITY 4 M O N 27 6.8 DIA. N 2.46 [62] 3 MOUNTING HOLES _ .88 [22] N m M 4.75 [121] 1.01 [26] B TANGENTIAL KNOCKOUTS FOR 3/4, 1 CONDUIT QUANTITY 1 NOTE: 1. METRIC DIMENSIONS (IN MILLIMETERS) [5.51 DIA. (5U ARE SHOWN IN BRACKETS. .281 .281 KNOQUANTITY 1 .82 [46 .82 [46 iv 2. WIRE RANGE OF LUGS IS AS FOLLOWS LINE AND LOAD LUGS #6-#14 COPPER OR ALUMINUM n N NEUTRAL (f4-#14 COPPER OR ALUMINUM n 6.10 [155] A . m u�aawmN ax nas or .oc rs TM[moaxn or umx asmdwoN WARREN SIPE 8/19/98 CUTLER -HAMMER IF T•N 5 a6rrD5m mx<nurtT "� PITTSBURGH PA ra m asap [x N - PoSF i0R N,4[N rt 6 NM�MFA 8/,./88 ^� DIMENSION SHEET nuua �:.PROKASKA urz 30 AMP TYPE 3R GENERAL DUTY 95-1445DWWG rmtau 0GCA N0.1 1-2 IT --95-1445 115 OF1 3 2 1 I Switching Devices Q Safety Switches 8.1 120/240 Vac General -Duty, Fusible, Single -Throw, continued H 1-1/1-3 OG321NRB — OG321NGB DG321NRB Maximum Horsepower Ratings 0 NEMA1 NEMA3R Ampere fuse Type Single -Phase AC Three -Phase AC OC Enclosure Indoor Enclosure Rainproof System Rating Provision 120V 240V 240V 250V Catalog Number Catalog Number Cartridge Type—Three-Pole, Three -Wire (Three Blades, Three Fuses) -240 Vee Iff 7-12-15 15-30 ddb 30 — — — — — 0 0 60 0 0 x 100 — — — — — O 0 7 200 — — — — 0 0 400 H — — 50-125 — DG325FGK00 1113325FRK00 600 H — — 75-200 — OG326FGK00 OG326FRK00 Cartridge Type—Four-Wire (Three Blades, Three Fuses, S/N)-120/240 Vac I I I 30 H 1-1/1-3 3-7-1/2 — OG321NGB DG321NRB OG322URB 60 H — 3-10 7-1/2-15 — DG322NGO OG322NRB Enclosure Indoor 100 H 7-12-15 15-30 DG323NGS OG323NRB I I I 200 H — 15 25-60 — DG324NGK UG324NRK 400 H — — 50-125 — DG325NGK OG325NRK 600 H — — 75-200 — OG326NGK OG326NRK 120/240 Vac General -Duty, Non -Fusible, Single -Throw OG322URB Maximum Horsepower Ratings NEMA1 NEMA 38 Single -Phase le -Phase AC Three -Phase AC DC Ampere i 9 Enclosure Indoor Enclosure Rainproof System Rating 120V 240V 240V 250V Catalog Number Catalog Number Two -Pole, Two -Wire (Two Blades) -240 Vac I 30 2 3 — — OG221UGO O DG221URB 0 60 3 10 — — OG222UGBr•r OG222URB r•> q q 100 — 15 — — OG223UGB(D OG223URB0 200 — — — — 01) G Three -Pole, Three -Wire (Three Blades) -240 Vac b b b 31 2 600 3 q 4 p 200 — 400 — 3 7-12 — DG321UGB0 OG321URB0 10 15 — OG322UGS0 OG322URB0 15 30 — OG323UGB O OG323URB 0 15 60 — OG324UGK0 DG324URK0 — 125 — DG325UGKOO DG325URK0 600 — — 200 — DG326UGK0 OG326URKO Nates O Maximum hp ratings apply only when dual element time delay fuses are used. 0 Use four -wire catalog numbers below. (D Solid neutral bars are not included. Order separately from table on Page 15. r•r WARNING! Switch is not approved for service entrance unless a neutral kit is installed. c" Use three -wire catalog numbers below. O Drilled to accept field installed neutral kits. All general -duty safety switches are individually packaged. Accessories are limited in scope on general -duty safety switches. See Page 15 far availability. In addition, clear line shields are available as an accessory on 200-600A general -duty switches. Catalog Numbers: 200A = 70-7759-11.400A = 70.8053.8.600A In 70.8064-8. Volume 2—Commercial Distribution CA08100003E—February 2011 www.eaton.com 27 FXeNx P01kO11719 BUS1110Si (':70flDWfde` r a 30�.DG221URB1 d 240., 'General Duty Safety Switch Aterru for de se uridad servicio fi ero 2 Pole Non -Fusible; series: Qry; ? polos sin fusibles series: B cant.: t MAGE 1N U.S.A.03/1$/2012 w i"C f Type 3R Rainproof HECHOENE.U.A. $5914$0 (NEMA) Tipo 3R a prueba de LI 7 82113 12023 2 4 3 2 I 4 3 2 D � D 6.89 [175] 8 1 6.81 [173] N 5.73 [145] , 6.36 [1621 .3a [9] ON N Ti - O ® n N b 0 o d m OFF ® ® ® O CONCENTRIC KNOCKOUTS FOR TANGENTIAL KNOCKOUTS FOR m1/2, 3/4 CONDUIT 1/2, 3/4 CONDUIT n ri _ �n Fol QUANTITY 2 QUANTITY 4 Ltl n o N - 27 [6.8 DIA. 2.46 [62j 3 MOUNTING HOLES N tv 3.75 [951 B rn rn ® 4.36 [111] m n tO 1.01 [26] TANGENTIAL KNOCKOUTS FOR 1/2, 3/4, 1 CONDUIT ' QUANTITY 1 NOTE: 1. METRIC DIMENSIONS (IN MILLIMETERS) 281 5.5] DIA.. [ ARE SHOWN IN BRACKETS. KNOCKOUT QUANTITY 1 [46 [46 2. WIRE RANGE OF LUGS IS AS FOLLOWS - LINE AND LOAD LUGS R ALUMINUM AOR .82 .82 n NEUTRAL #4-�f 14 COPPER ALUMINUM - 6.10 6.10 [155] - 4 1 A tl . S TME rwovtxn ac umx awrv91ro1, WARREN SITE 8/19/9s CUTLER -HAMMER 116 u.9RuligM OH 11P5 R 66_T•N am x araoxt •ro WA BE PRTSBURGN PA $ ° O1H r m"`- R. PRGNASKA 8/19/98 ^^< DIMENSION SHEET •a twu arz 30 AMP TYPE 3R GENERAL DUTY m 95-1445. WG , - 55740GCI I -2 n c. --95-1445 11 OF I 4 3 2 1 Mr.. ZepSolar Datasheet: ZS Tile ZS Tile'" offers the fastest and least expensive way to install PV arrays on tile roofs. It's designed to interoperate with a growing list of Zep Compatible PV modules that incorporate the patented Zep Groove frame specification. Utilizing quarter -turn, rock -in, and drop-in con- nections, ZS tile eliminates the need for rails and separate grounding hardware while offering a superior aesthetic approach. Key System Benefits Dramatically reduces installation time Eliminated mounting rails and clip hardware Eliminates separate grounding hardware Rapid, top -accessible precision array leveling Ultra -reliable hyper -bonded grounding matrix Uttra-low parts count Enhanced aesthetics Key Technical Features Low system weight Easily enables additional support at array edges for high wind applications Interlock ETL listed to UL 1703 as ground bond means Ground Zep UL and ETL listed to UL 467 as grounding and bonding device Interlock, Leveling Foot, and Ground Zep listed to UL 2703 as PV bonding device Zep Compatible" ZS Tile mounting hardware is designed for use with Zep Compatible' PV modules from leading PV module Manufacturers. Visit zepsolar.com for a current list of Zep Compatible`" PV modules. Our Other Product Families NY �ONPA)re� pOW �L LISTED OONpP� Page 1 of 2 Datasheet: ZS Tile Components Interlock _ The Interlock provides north -south and east -west structural and ground bond connections creating a structurally contiguous hyper -bonded array. Interlock UL listed to UL 2703 and ETI -listed to UL 1703. Leveling Foot(31.8mm) + (30.7mm1 fes- 1.25in 1.21in _____T�-pp -qq 157.2mm] m 139.4m) 111PPPP1ll--ggqqlll2ll T 2.25in I.SSi�� [81.2^� f fs' 3.200ln - in 4.O0in The Leveling Foot provides a means of attachment between the PV array and the mounting surface or flashed attachment apparatus and allows for easy array height adjustment (1.25' throw). Array Skirt e� The Army skirt facilitates easy front -row installation while providing a clean look at the front of the PV array. Ground Zep The Ground Zep provides a point of connection between the PV array and the equipment grounding conductor. One Ground Zep is required for every 72 PV modules. UL and ETL listed to UL 467. UL listed to UL 2703. Universal Box Bracket AC/DC Cable Clip Replacement Tile The Universal Box Bracket allows rapid attachment of Clips into Zep Groove for ultra -fast and easy 'rhe Replacement Tile provides a means of flashed electrical boxes to the module frame. management of PV wiring and micro -inverter cables. attachment for ZS Tile installations. Array Skirt Cap Set Tools ILI The Array Skirt Cap Set provides an aesthetic cover for Zep Tool: 4 functions. I toot; Flat Tool: For inter -module the exposed end of the Array Skirt. Made of anodized removal. aluminum, each set comes with two Skirt Caps. This doormat does our ante arty stpeu werranty by In Solar mabom its shoduus or senius rep Solars We wananly is mntalned in themitten authors wanamy lot each Visit repsolor.wm for more information about our produchand summary. mal. The enksei documentation shipmsd with Zell Saha s Producbamtitrus, the Weunalurniomrefnred tom the product warranty. Thecuvonaa Is Wall responsible kr nrihtM the solubility of105oWs products for each ue. Specifications an, subm to dGnge iihm notice Cartoon a 2010 - M? Zep Solar. 1. BS. Patent A15W. IIS Patent B,I�,0/&OShcmlPatents Perdim} tau Updatchbnury25,20133:tIPN Page 2 of 2 9 ZS Aero for low -slope & flat roofs ZS Comp - for composition shingle roofs ZS Seam for standing seam metal roofs OZS Span - for rail -based applications ZS Trap - for trapezoidal metal roofs OZS Wave - for corrugated roofs NY �ONPA)re� pOW �L LISTED OONpP� Page 1 of 2 Datasheet: ZS Tile Components Interlock _ The Interlock provides north -south and east -west structural and ground bond connections creating a structurally contiguous hyper -bonded array. Interlock UL listed to UL 2703 and ETI -listed to UL 1703. Leveling Foot(31.8mm) + (30.7mm1 fes- 1.25in 1.21in _____T�-pp -qq 157.2mm] m 139.4m) 111PPPP1ll--ggqqlll2ll T 2.25in I.SSi�� [81.2^� f fs' 3.200ln - in 4.O0in The Leveling Foot provides a means of attachment between the PV array and the mounting surface or flashed attachment apparatus and allows for easy array height adjustment (1.25' throw). Array Skirt e� The Army skirt facilitates easy front -row installation while providing a clean look at the front of the PV array. Ground Zep The Ground Zep provides a point of connection between the PV array and the equipment grounding conductor. One Ground Zep is required for every 72 PV modules. UL and ETL listed to UL 467. UL listed to UL 2703. Universal Box Bracket AC/DC Cable Clip Replacement Tile The Universal Box Bracket allows rapid attachment of Clips into Zep Groove for ultra -fast and easy 'rhe Replacement Tile provides a means of flashed electrical boxes to the module frame. management of PV wiring and micro -inverter cables. attachment for ZS Tile installations. Array Skirt Cap Set Tools ILI The Array Skirt Cap Set provides an aesthetic cover for Zep Tool: 4 functions. I toot; Flat Tool: For inter -module the exposed end of the Array Skirt. Made of anodized removal. aluminum, each set comes with two Skirt Caps. This doormat does our ante arty stpeu werranty by In Solar mabom its shoduus or senius rep Solars We wananly is mntalned in themitten authors wanamy lot each Visit repsolor.wm for more information about our produchand summary. mal. The enksei documentation shipmsd with Zell Saha s Producbamtitrus, the Weunalurniomrefnred tom the product warranty. Thecuvonaa Is Wall responsible kr nrihtM the solubility of105oWs products for each ue. Specifications an, subm to dGnge iihm notice Cartoon a 2010 - M? Zep Solar. 1. BS. Patent A15W. IIS Patent B,I�,0/&OShcmlPatents Perdim} tau Updatchbnury25,20133:tIPN Page 2 of 2 9