Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
SFD (13-0338)
.l P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 •4.4 " VOICE (760) 777-7012 FAX (760) 777-7011 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Application Number: 13-00000338 Property Address: 53385 AVENIDA MENDOZA APN: 774-092-019-7 -000000- Application description: DWELLING - SINGLE FAMILY DETACHED Property Zoning: COVE RESIDENTIAL Application valuation: 126301 Applicant: Architect or Engineer: 0 LICENSED CONTRACT R'S DECLARATION I hereby affirm under penalty of perjury that I a ensed un r rovisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business rofessi de a Wy License is in full force and effect. License Class: B n 67583 CIA.e( ( Contractor ow OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and.the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT Owner: ROPER MORRIS CONSTRUCTION 51200 CALLE PALOMA LA QUINTA, CA 92253 r7-- (760)272-9292 —(760)272-9292 IID Contractor: MORRIS CONSTRUCTION INC 78930 STARLIGHT LANE BERMUDA DUNES, CA 92203 (760)272-9292 Lic. No.: 867583 Date: AUG 16 2013 cirYFIAt of � � A a e... _ 8/13/13 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT AkW ertify that, in the performan f the work f which this permit is issued, I shall not employ any person in any manner so to "come su c o the workers' compensation laws of California, and agree that, if I sho b ome su 'ec o e w ' compensation provisions of Section 37000 of the Labor Co , 1 all fort it wit ose provisions. Date: �EI /i.1 ) Applica WARNING: FAILURE TO SECURE ORKERS OMPENSATIOJCERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES ANDS UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees -to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above i ormatikan agree to comply with all city and county ordinances and state laws relating to building c ruction,ize representatives of this county to enter upon the above-mentioned property m ectio Daature (Applicant or Age n C -t_ Application Number . . . . . 13-00000338 Structure Information Construction Type . . . . . TYPE V, UNPROTECTED Occupancy Type . . . . . DWELLG/LODGING/LONG <=10 . Other struct info . . . . . CODE EDITION 2010 # BEDROOMS 3.00 FIRE SPRINKLERS yes GARAGE SQ FTG 458.00 PATIO SQ FTG 167.00 NUMBER OF UNITS 1.00 ---------------------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 1941.00 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 734.00 Plan Check Fee 477.10 Issue Date . . . . Valuation . . . . 126301 Expiration Date 11/17/13 - Qty Unit Charge Per Extension BASE FEE 639.50 27.00 3.5000 ---------------------------------------------------------------------------- THOU BLDG 100,001-500,000 94.50 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 107.10 Plan Check Fee 26.78 Issue Date . . . . Valuation . . . . 0 Expiration Date 11/17/13 Qty Unit Charge Per Extension BASE FEE 15.00 1941.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 67.94 458.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 9.16 1.00 15.0000 ---------------------------------------------------------------------------- EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee :00 Issue Date . . . . Valuation . . . . 0 Expiration Date 11/17/13 Qty Unit Charge Per Extension ---------------------------------------------------------------------------- BASE FEE 15.00 Permit . . . . . . MECHANICAL LQPERMIT Application Number . . . . . 13-00000338 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 73.00 Plan Check Fee_ 18.25 Issue Date . . . . Valuation 0 Expiration Date 11/17/13 Qty Unit Charge Per, Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 16.50 4.00 6.5000 EA MECH VENT FAN 26.00 1.00 6.5000 -----------=-------------------------------------------=-------------------- EA MECH EXHAUST HOOD 6.50 Permit . . PLUMBING Additional desc . Permit Fee . . . . 146.25 Plan Check Fee ... 36.56 Issue Date Valuation 0 Expiration Date 11/17/13 Qty Unit Charge Per Extension" BASE FEE 15.00 13.00 6.0000 EA. PLB FIXTURE 78.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 5.00 .7500 EA PLB GAS PIPE >=5 3.75 1.00 15.0000 EA PLB GAS METER 15.00 ----------------------------------------------------------------------------- Special Notes and Comments 1941 sf SFD. 2010 CODES W/ FIRE SPRINKLERS. 2013 DIF. TUMF. ENGINEER: REZA ASGHAPOUR C67613. **PERMIT DOES NOT INCLUDE BLOCK WALLS, FENCES, SWIMMING POOLS, SPA, BBQ'S and DRIVEWAY APPROACH** ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 6.00 DIF COMMUNITY CENTERS-RES 129.00 DIF CIVIC CENTER - RES 942.00 ENERGY REVIEW FEE 47.71 DIF FIRE PROTECTION-RES 433.00 GRADING PLAN CHECK FEE 15.00 DIF LIBRARIES - RES 344.00 MULTI-SPECIES (MSHCP) FEE 531.00 DIF PARK MAINT FAC - RES 40.00 DIF PARKS/REC - RES 2048.00 LQPERMIT .Application Number . . . . . 13-00000338 ------------------------------- Other Fees . . . --------------------------------------------- . . . . . COVE PRECISE PLAN FEE 100.00 STRONG MOTION (SMI) - RES 12.63 TUMF: RESIDENTIAL 1837.44 DIF STREET MAINT FAC -RES 116.00 DIF TRANSPORTATION - RES 2842.00 Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 1075.35 .00 .00 1075.35 Plan Check Total 558.69 250.00 .00 308.69 Other Fee Total 9443.78 .00 .00 9443.78 Grand Total 11077.82 250.00 .00 .10827.82 LQPERMIT Building T-itT44a" P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 uwner oPe✓ /vpor�t's.o,�s I anu iy Address v too Cm_e,,.. ` Vow City Zip Tel � Qu,� 9r�s3 Tel. .,u Contractor V Address City Zip 9� el. 7 72-%�%� State Lic.City /�''r/ & Classif. X07 6-0 3 Lic. # O� r/ l - Designer Address Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) or Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own em to ees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). 111, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT.' It, alter making this Certificate of Exemption you should become subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT APPLICATION ONLY BUILDING: TYPE CONST. G� OCC. GRP. T7L `0`a A.P. Number 'b0 Legal Description- Project escription Project Description q a 6":9 - 349 S j4l/?—P -�a— Sq. Ft. p!No. l No. Dw. t Size Stories Units New Add ❑ Alter ❑ Repair ❑ Demolition ❑ IEstimated Valuation "'SEw .4'17S_,~ PERMIT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Driveway Enc. Infrastructu,e CIT OFLAQUINTA I ciieruCF nr-Pl11 - TOTAL REMARKS e AMOUNT ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE Issued by: Validated by:_ Validation: YELLOW = APPLICANT INSPECTOR Date Permit PINK = FINANCE A^ CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road Date 8/12/13 La Quinta, CA 92253 No. 31772 (760) 771-8515 Owner Roper Morris Construction, Inc. APN # Address 51200 Calle Paloma Jurisdiction City La Quinta Zip Permit # Tract # No. of Units Type Single Family Residence Lot # No. Street S.F. Lot # No. Unit 1 53385 Avenida Mendoza 1941 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments certs #31772 & 31773 used for chk totaling $12422.40 ���ZF1:Eps,Ct BERMUDA DUNES r Cn RANCHO MIRAGE b INDIAN WELLS PALM DESERT y. t, LA QUINTA �INDIO K^� Q Y✓ 774-092-019 La Quinta 1 Street S.F. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $3.20 X 1,941 S.F. or $6,211.20 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Bank Of America - Roper Morris Check No. 002907563 Bank Name/Recipient of Certificate Telephone 760-272-9292 Funding Residential By Dr. Gary Rutherford Superintendent ` "C 4•*N" SII • � arj Fee collected /exemp d by Shar MCGp fey Payment Recd $6,211.20 'Over/Wid, r = `•� . �. Signature ;:�,".';�;.`" '*`4rff1r 4%'` NOTICE: Pursuant to Government Code Section 66020(d)(1), this wif terve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting RECORDING REQUESTED BY First American Title Company AND WHEN RECORDED MAIL DOCUMENT TO: Roper Morris Construction, Inc. 51200 Calle Paloma La Quinta, CA 92253 DOC # 2013-0161440 04/04/2013 04:03 PM Fees: $21.00 Page 1 of 3 Doc T Tax Paid Recorded in Official Records County of Riverside Larry W. Ward Assessor, County Clerk & Recorder —This document was eleEtronically submitted to the County of Riverside for recording— Receipted by: AGONZALEZ t Space Above This Line for Recorder's Use Only A.P.N.: 774-092-019-9 and 774-092- T.R.A. No.020-015 File No.: RIW-4297521 (KC) 020-9 The Undersigned Grantor(s) Oeclare(s): DOCUMENTARY TRANSFER TAX $100.10; CITY TRANSFER TAX $0.00; x computed on the consideration or full value of property conveyed, OR computed on the consideration or full value less value of liens and/or encumbrances remaining at time of sale, ( unincorporated area; ( x I City of La Quints, and FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Mark Steven Pecheck and ]on Scott Pecheck, Successor Trustees of the Marie L. Pecheck Trust dated August 2S, 2007 hereby GRANTS to Roper -Morris -Construction Inc. a California°corporation the following described property in the City of La Quinta, County of Riverside, State of California: LOTS 7 AND 8 IN BLOCK 212 OF UNIT NO. 20, SANTA CARMELITA AT VALE LA QUINTA, AS SHOWN BY MAP ON FILE IN BOOK 19 PAGE 38 OF MAPS, RECORDS OF RIVERSIDE COUNTY, CALIFORNIA. Mail Tax Statements To: SAME AS ABOVE 4 f��f tai Building & Safety Department 78-495 Calle Tampico PO Box 1504 La Quinta, CA 92253 (760) 777-7012 voice — (760) 777-7011 fax To: Greg Butler, Building Official To PD: April 23; 2013 From: Les Johnson, CDD Director Due date: April 30, 2013 Permit #13-340. Status: 1St review Building Plans Approval (This is an approval to issue a Building Permit) The Planning Division has reviewed the Building Plans for the following project: Description: SFD — Cove Check Addressor general location: 53385 Avenida Mendoza Applicant Contact: Roper Morris Construction, (760)272-9292 The Planning Division finds that: ❑ ...these Building Plans do not require Planning Division approval. these Building Plans are approved by the Planning Division,. O ...these Building Plans require corrections. Please forward a copy of the attached cor ections to the applicant. When the corrections are made pleas returr them to the Planning Division for review. Les Jo son, ,pm unity Development Director Date Note: PLEASE RETURN PLANS WITH GREENSHEET TO THE BUILDING DIVISION. CITY OFLA QUINTA BP No. Exempt(no recycling) HOA Approval Construction & Demolition Debris Management Plan Construction and Demolition (C&D) debris is waste material that is produced in the process of construction,'renovation, or demolition of structures. The City of La Quinta requires at least 50% diversion. Recycling helps to keep reusuable resources out of the landfills and will also reduce disposal costs. KEEP A COPY OF THIS PLAN AT THE WORK SITE SHADED AREAS TO BE COMPLETED BY THE CITY 5/17/2013 Plan Submittal Date SMALL HOME CONSTRUCTION Project Name / Description 53805/53405 AVENIDA MENDOZA Job Site Address ROPER MORRIS CONST Owner's Name 51200 CALLE PALOMA Owner's Mail Address ROPER MORRIS CONST Project's Name / Company ROPER: 760-272-9292 Project Managers Cell Phone Number iClty1 00— l by Plan Approval Date Tract Number / APN No. APPROX 1400 SQ FT EACH Project Square Feet / Total Acreage of Project 760-272-9292 Owner's Phone Number LA QUINTA, CA. 92253 City, State, Zip 760-272-9292 Project Manager's Phone Number roper morris@_yahoo.com Fax Email €Date City Approved I hereby certify that completion, implementation and adherence of the Debris Management Plan ("DMP") for the above named project shall guarantee a minimum of 50% diversion of all materials generated from the first day of the project through the completion of the project in accordance with the reuse and recycling methods identified on the attached worksheet. This DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) shall be kept informed of the progress of the DMP. Violation of this ordinance may include fines and/or incarceration. Owner / Developer / Project Manager Date SAVE MONEY, PROTECT THE ENVIRONMENT, ONLY USE LICENSED WASTE & RECYCLING FACILITIES, RECYCLE! Distribution: WHITE - Environmental Programs Coordinator, CANARY - Building Dept; PINK - Permit Holder, GOLD - Burrtec Form: CDDMP-01 Construction & Demolition Debris Management Plan SUMMARY PLAN' Tonnage calculations derived from Plan Worksheet are to be placed in Column A below. The Construction Representative will assist you to determine the most practical destinations for these waste materials keeping in mind the City's minimum diversion requirements together with your project's space, time, labor, and budget limitations. Material Category Asphalt/Concrete Asphalt r Concrete Brick/Masonry/Tile Brick Masonry block (broken) Tile (roof) Tile (flooring) Plaster Building Materials (Doors, fixtures, Windows, Plate Glass, cabinets, Other) Cardboard Carpet Drywall, new or used Furniture Landscape Debris Scrap Metal Wood, pallets, clean, unpainted (no pressure treated lumber) Garbage/Trash Other (Please specify) COLUMN TOTALS - Column A Tons 0.00 Column B Salvage/Reuse 0.00 Column C Recycle 0.00 Column D Disposal 0.00 Column E Destination 0.00 0.00 0.00 0.00 0.00 0.00 16.00 0.00 16.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.001 0.00 0.00 0.00 0.00 0.25 0.00 0.25 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2.50 0.00 2.501 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.25 0.00 1.25 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.001 0.00 0.00 0.00 0.00 0.001 0.00 0.001 0.00 0.00 3.50 0.00 3.50 0.00 0.00 0.00 0.00 0.00 0.00 0.00 11.50 0.00 0.00 11.50 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 35.00 0.00 23.50 11.50 Diversion Calculation 1 Column B Total 0.00 2 Column C Total 23.50 23.50 3 Sum of above 4 Divide answer 3 by Column A Total 0.67 Your diversion goal for this project -► 67.14% Owner /Developer/ Project Manager agreement of Construction & Debris Plan If Diversion Percentage is less than 50% a Representative will make recommendations to assist you in achieving your project's compliance requirements. NOTE: Burrtec Waste is the ONLY Company authorized to collect solid waste (trash) in La Quinta. For information regarding the legal hauling of recycled materials call Kenn Stevens (760) 578-5215. Distribution: WHITE -Environmental Programs Coordinator, CANARY -Building Dept; PINK -Permit Holder, GOLD-Burrtec Form: CDDMP-01 'PROUDLY SERVING THE UNINCORPORATED AREAS OF RIVERSIDE COUNTY AND THE CITIES OF: BANNING BEAUMONT CALI M ESA CANYON LAKE COACHELLA DESERT HOT SPRINGS EASTVALE INDIAN WELLS INDIO LAKE ELSINORE -LA QUINTA MENIFEE MORENO VALLEY PALM DESERT PERRIS RANCHO MIRAGE RUBIDOUX CSD SAN JACINTO TEMECULA WILDOMAR BOARD OF SUPERVISORS: BOB BUSTER DISTRICT 1 JOHN TAVAGLIONE DISTRICT 2 JEFF STONE DISTRICT 3 JOHN BENOIT DISTRICT 4 MARION ASHLEY DISTRICT 5 RIVERSIDE. COUNTY FIRE DEPARTMENT IN COOPERATION WITH THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION 77-933 Las Montanas Rd., Ste. #201, Palm Desert,!CA 922114131 • Phone (760) 863-8886 • Fax(760)863-7072 www.rvcfiire.org April 22, 2013 Kincaid 31-065 Plantation Drive Thousand Palms, CA Re: Residential Fire Sprinkler Plan Review LAQ-13-RS-23 53-385 Avenida Mendoza La Quinta, CA The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County. Fire Department Planning & Engineering personnel and are approved with the following conditions: A minimum of three spare fire sprinklers of each type and temperature rating along. with a sprinkler wrench should be located in a spare head cabinet at the system riser or other approved location. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed'by the Fire Department Planning Division staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. l (b) Final inspection. The Fire Department job card, approved plans and conditions letter must be at the job site or NO inspection will be performed. Applicant/installershall be responsible to contact the Fire Department to schedule inspection(s) a minimum of 72 hours prior to the requested inspection date. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863-8886. Applicant/installer shall be responsible to contact the Fire Department to sche ule in pection. Sincerely, Jason Stubble Fire Safety Specialist CITY: OF LA QUINTA-SUB-CONTRACTOR LIST Q JOB ADDRESS 633K . All. M 8NVO PERMIT NUMBER OWNER BUILDER This form shall be posted'on the job with the Building Inspection Card at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized to wor on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result ina stoppage of work and/or the voidanc. . of building permit. For each applicable trade, all information requested below must be completed by applicant. "On File" is not an acceptable response. Trade T Classification C a :,;:•. ; :.:... tate::Contcactor.s LaCerise. ;•.. :. Workers Corrlpensatlon:)nsuranCe:':<': .:>:....<<::.. City Business License Company Name Classification (e.g. A, B, C-8) License Number (xxxxxx) Exp. Date (xx/xx/xx) Carrier Name (e.g. State Fund, CalComp) (�. � W GI ��'�(� �&Ill[� (7� Policy Number (Format Varies) Exp. Date (xx/xx/xx) License Number (xxxx) Exp. Date (xx/xx/xx) EARTHWORK (Cr12)':."..:. HMC'Q� �/M/i �'I�/'N� I �'d �pDOZ$� 1►I� f3 j y�og(O�%��%O((� y g CONCRETE (c -s).:::.:. CA1� SfAg .rr GoY� G- lb 973S7y dd ��i ////3/�,S�l�lo //!� FRAMING :((G-5) :`..:' :. A'bb 05104-t�3c-- � �0� � -!v' -7� 1 'S+k%G f;A4fi 9D.3���Z ---13!. 1-/Y. 3-74 STRUCT::STEEL'(G-51) � MASONRY 1C-29) '". PLUMBING lC-361 (1p.IVA"N p luwsbi 04 is C 3 Jo S�SBNr°I ®31 13 -rw-fit Ne /O 9 D $? ?j 1 /3/7 LATH; PLASTER (C=35) ' y �kNT7�iiFi IAS ivV C r C' g �J�� �'� 73xwcH I &wr., C STs-oo T s8g N / 10407y DRYWALL (C-9).-,-. U(A'1�1 �t L1IbI 1 c35c9. $q Kd3 lS � &4Aw<(,',jTsnU�a I'/y la6d77 9 HVAC. (C720T .:: ' : ..: �j I MIf4owS q i ✓LdS3' j o� ! 5-ri�r� �> 0 90 , T b i 5-1V 6 Li 2.7 • /�i ELECTRICAL. (C- 6)-:. , ROOFING 39Y.-: `- h1►t Q C.�3 ` 1 / (� C q17-// / J �� � p/ ��011 �rv� G�CA472YI S --/q X0.7&77 7.•/ SHEET METAL (043) ` FLO01RING IC151; GLAZING (C-17} INSULATION (C-2) SEWAGE DISP- (G-42) PAINTING (C-33) TWA 01A� �/ti fL:T 2 . �i C 3 7 3 %3 30 10 a • /s - I l'Ve.f ClsT Alwv DI oro 7:�W 7Fs— I �'� �i% � 3 � � � �'Z1 ' rj CERAMIC TILE (C-54) CABINETS IC -6) �� er5 PO4 /36a7& 9' / q871y��y FENCING (C-13) LANDSCAPING (CG27) . ? POOL (C-53) BUILDING ENERGY ANALYSIS REPORT PROJECT: Morris Residence 53-385 Avenida Mendoza La Quinta, CA Project Designer: RECEIVED MAR 212013 CITY OF LA QUINTA COMMUNITY DEVELOPMENT • Report Prepared by: Joan D. Hacker Insu-form, -Inc. 77810 Las Montanas Road, Suite 201 _Palm Desert, Ca 92211 760-345-1352 C Y OF LA OU1NT DEPT. FOR CONSTRUCTION 44 Job Number:,! CAT Date: 3/18/2013 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 bEne SoR User Number. 2655 RunCode: 2013-03-18716:28:51 ID: TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1R Certificate of Compliance 3 Form MF -1R Mandatory Measures Summary 9 HVAC System Heating and Cooling Loads Summary 12 EnergyPro 5.1 by EnergySoft Job Number: ID: User Number. 2655 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Morris Residence Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addibon/Afteration 13/18)2013 Date Project Address 53-385 Avenida Mendoza La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,941 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No HERS Measures -- If Yes, A CF -411 must be provided per Part 2 of 5 of this form. E3 Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavi Features see Part 2 of 5 Status Wall Wood Framed R-21 812 New Roof Wood Framed Attic R-38 1,941 Radiant Barrier New Slab Unheated Slab -on -Grade None 1,941 Perim = 168' New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Front (E) 48.0 0.500 0.38 8.0 none Bug Screen New Left (S) 88.0 0.500 0.38 2.0 none Bug Screen New Rear (IM 76.5 0.500 0.38 2.0 none Bug Screen New Right (N) 46.0 0.500 0.38 2.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Fumace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status Whole House Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Small Gas 50 0.62 All Pipes Ins New EneWPro 5.1 by EnergySoft User Number. 2655 RunCode. 2013-03-18716:28:51 ID: 3 of 12 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Morris Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration I Date 1311812013 SPECIAL FEATURES INSPECTION CHECKLIST • The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 1, 000.0 ft2 Exposed Slab Floor, 3.500" thick at Whole House HIGH MASS Design - Verify Thermal Mass: 941.0 ft2 Covered Slab Floor, 3.500" thick at Whole House The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria -as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Amana RSD60A2A includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System Whole House incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System Whole House incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnergyPro 5.1 bTEnergySoft User Number. 2655 RunCode: 2013-03-18T16:28:51 ID: Page 4 of 12 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type 0 Single Family ❑ Addition Alone Date Morris Residence 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 3/18/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 2.16 1.85 0.32 Space Cooling 43.41 42.83 0.58 Fans 8.87 11.02 -2.16 Domestic Hot Water 16.63 15.07 1.56 Pumps 0.00 0.00 0.00 Totals 71.07 70.77 0.30 Percent Better Than Standard: 0.4% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 180 48 Fuel Available at Site: Natural Gas (S) 280 88 Raised Floor Area: o (►M 330 77 Slab on Grade Area: 1,941 (N) 280 46 Average Ceiling Height: 10.0 Roof 1,941 0 Fenestration Average U -Factor: 0.50 TOTAL: 259 Average SHGC: 0.38 Fenestration/CFA Ratio: 13.3% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of'Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company /nsu-form, Inc. 3/18/2013 Address 77810 Las Montanas Road, Suite 201 Name Joan D. Hacker City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Address Name City/State/Zip Phone S Vned License # Date EnercivPro 5.1 by EnemySoft User Number: 2655 RunCode: 2013-03-18716:28:51 ID: Pa - e 5 of 12 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Morris Residence Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/AReration Date 3/18/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Wall 132 0.069 R-21 90 90 New 4.3.1-A6 Whole House Wall 192 0.069 R-21 180 90 New 4.3.1-A6 Whole House Wall 254 0.069,R-21 270 90 New 4.3.1-A6 Whole House Wall 234 0.069 R-21 0 90 New 4.3.1-A6 Whole House Roof 1,941 0.025 R-38 90 0 New 4.2.1-A21 Whole House Slab 1,000 0.730 None 0 180 New 4.4.7-A1 Whole House Slab 941 0.730 None 0 180 New 4.4.7-A 1 Whole House FENESTRATION SURFACE DETAILS ID I Type Area 11 -Factor SHGCz Azm Status Glazing Type Location/Comments 1Window 48.0 0.500 NFRC 0.38 NFRC 90 New IWC 6200 Alurnkow-E Whole House 2 Window 20.0 0.500 NFRC 0.38 NFRC 180 New IWC 6200 Alurnkow-E Whole House 3 Window 24.0 0.500 NFRC 0.38 NFRC 180 New IWC 6200 Alum2ow-E Whole House 4 Window 20.0 0.500 NFRC 0.38 NFRC 180 New IWC 6200 Alumkow-E Whole House 5 Window 4.0 0.500 NFRC 0.38 NFRC 180 New IWC 6200 Alurnkow-E Whole House 6 Window 8.0 0.500 NFRC 0.38 NFRC 180 New IWC 6200 Alurnkow-E Whole House 7 Window 4.0 0.500 NFRC 0.38 NFRC 180 New IWC 6200 Alum/Low-E Whole House 8 Window 8.0 0.500 NFRC 0.38 NFRC 180 New IWC 6200 Alurnkow-E Whole House 9 Window 40.0 0.500 NFRC 0.38 NFRC 270 New IWC 6200 Alum/Low-E Whole House 10 Window 12.0 0.500 NFRC 0.38 NFRC 270 New IWC 6200 Alurnkow-E Whole House 11 Window 8.0 0.500 NFRC 0.38 NFRC 270 New IWC 6200 Alum/Low-E Whole House 12 Window 16.5 0.500 NFRC 0.38 NFRC 270 New IWC 6200 Alum/Low-E Whole House 13 Window 1.5 0.500 NFRC 0.38 NFRC 0 New IWC 6200 Alumkow-E Whole House 14 Window 1.5 0.500 NFRC 0.38 NFRC 0 New IWC 6200 Alumkow-E Whole House 15 Window 1.5 0.500 NFRC 0.38 NFRC 0 New IWC 6200 Alurnkow-E Whole House 16 Window 1.5 0.500 1 NFRC 1 0.38 1 NFRC 0 New IWC 6200 Alum2ow-E Whole House (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hot Wd Ove hang Left Fin Ri ht Fin Len Hat I LExt RExt Dist I Len Hat Dist Len Hat 1 Bug Screen 0.76 8.0 6.0 8.0 0.11 8.0 8.0 2 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 6.0 4.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 5.0 4.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 4.0 2.0 2.0 0.1 2.0 2.0 7 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 4.0 2.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 2.0 6.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 4.0 2.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 5.5 3.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 1.5 1.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 1.5 1.0 2.0 0.1 2.0 2.01 1 15 Bug Screen 0.76 1.5 1.0 2.0 0.1 2.0 2.01 1 16 Bug Screen 0.76 1.5 1.0 2.0 0.1 2.0 2.01 1 EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2013-03-18T16:28:51 ID: Page 6 of 12 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Morris Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1311812013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC2 Azm Status Glazing Type Location/Comments 17 Window 20.0 0.500 NFRC 0.38 NFRC 0 New IWC 6200 Alum/Low-E Whole House 18 Window 20.0 0.500 NFRC 0.38 NFRC 0 New IWC 6200 A/umkow-E Whole House (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Right Fin ID Exterior Shade Type SHGC Hot Wd Len Hot LExt RExt Dist Len Hot Dist Len Hot 17 Bug Screen 0.76 5.0 4.0 2.0 0.1 2.0 2.0 18 Bug Screen 0.76 5.0 4.0 2.0 0.1 2.0 2.0 EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2013-03-18716:28:51 ID: Pa e 7 of 12 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5) CF -1 R Project Name Morris Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1311812013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built Whole House Whole House 1,941 19,410 Totals 1,941 01 0 0 HVAC SYSTEMS System Name Cly. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Whole House 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status Whole House Ducted Ducted Attic, Ceiling Ins, vented 8.0 0 New 13 WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input 8tuh Tank Cap. ai Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status A. 0. SMITH FPS -50-224 1 Small Gas All Pipes Ins 43,000 50 0.62 Na Na New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length (ft)0 0 in a CQ a -c System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried 01 ❑ Ene Pro 5.1 by EnergySoft User Number. 2655 RunCode: 2013-03-18T16:28:51 ID: Page 8 of 12 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Morris Residence Date 1311812013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)l B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinci sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-8 and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 1500)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro5.1 by EnergySoft User Number. 2655 RunCode: 2013-03-18716:28:51 ID: Page 9 of 12 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Morris Residence 1311812013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergYPro5.1 by EnergySoft User Number: 2655 RunCode: 2013-03-18716:28:51 ID: Page 10 of 12 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Morris Residence 1311812013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy.. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are•not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed. luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be hi h efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnefgySoft User Number. 2655 RunCode: 2013-03-18T16:28:51 ID: Page 11 of 12 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Morris Residence Date 3/18/2013 System Name Whole House Floor Area 1,941 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 741 17,774 Return Vented Lighting 0 Return Air Ducts 1,026 Return Fan 0 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 1,026 TOTAL SYSTEM LOAD 19,826 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output per System 70,000 2,012 555 20,415 Total Output Stuh 70,000 Output Btuh! 36.1 1,003 Cooling System 0 Output per System 58,000 0 0 0 Total Output Btuh 58,000 2,012 0 Total Output ons 4.8 1,003 Total Output (Btuh/ 29.9 Total Output on 401.6 22,422 Air System CFM per System 2,055 HVAC EQUIPMENT SELECTION Airflow(cfm) 2,055 Amana RSD60A2A 43,859 5,834 70,000 Airflow chn/s 1.06 Airflow cf nrron 425.2 70,000 Jan 1 AM Outside Air % 0-0% Total Adjusted System Output 1 43,859 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 5,834 Aug 3 PM Outside Air cfm/s 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF Outside Air 0 cfm Supply Fan 2,055 cfm 70 OF 70 OF 105 OF Heating Coil 105 OF ROOM �I 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 78!63°F 78/63°F 55/54°F c c Outside AirAr 0 cfm Supply Fan Cooling Coil 55 / 54 OF 2,055 cfm 42.2% ROOM 78/63°F 78/63°F EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2013.03-18716:28:51 /D: Page 12 of 12 Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com - 4/25/2013 Electronically Signed at CalCERTS.com by Justin R Morris (Roper Morris Construction) 4/26/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Morris Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Afterabon Date 4/25/2013 Project Address 53-385 Avenida Mendoza La Quinta Califomia Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,941 Addfion n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status Wall Wood Framed R-21 920 New Roof Wood Framed Attic R-38 1,941 Radiant Barrier New Slab Unheated Slab -on -Grade None 1,941 Perim = 103' New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Front (E) 48.0 0.500 0.36 8.0 none Bug Screen New Left (S) 70.0 0.500 0.36 2.0 none Bug Screen New Rear (l47 76.5 0.500 0.36 2.0 none Bug Screen New Right (N) n Bu Screen New —1 CITY OF LA Q1 IINTA-i r BUILDING & SA I FOR =E1 Yt:LJ oA I L .- . HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status Whole House Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Small Gas 50 0.62 All Pipes Ins New EnergyPro 5.1 ?X Ene'WSoft User Number. 2655 RunCode: 2013.04-25709:32:51 1D: Pa 1 of 6 Reg: 213-N002+t581A09(I R00-0000 Registration Date/Time: 2013/04/25 12:35:20 HERS Provider: Ca10ERTS, Inc CITY OF LA QUINTA COMMUP=]TY DEVELOPMENT Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com - 4/25/2013 Electronically Signed at CalCERTS.com by Justin R Morris (Roper Morris Construction) 4/26/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Morris Residence Building Type ® Single Family 0 Addition Alone 1 0 Multi Family ❑ Existing+ Addition/Afteration Date 412512013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special iustification and documentation submitted. HIGH MASS Design - Verify Thermal Mass. 1,000.0 ft' Exposed Slab Floor, 3.500" thick at Whole House HIGH MASS Design - Verify Thermal Mass: 941.0 ft' Covered Slab Floor, 3.500" thick at Whole House The Roof R-38 Roof Attic includes credit for a Radiant Barmier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Amana RSD60A2A includes credit for a4 1.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System Whole House incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System Whole House incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2013-04-25709:32:51 ID: Page 2 of 6 Reg: 213-N0024581A-000000000-0000 Registration Date/Time: 2013/04/25 12:35:20 HERS Provider: Ca10ERTS, Inc Electronically Filed by Joan D. Hacker and Authenticated at Ca10ERTS.com - 4/25/2013 Electronically Signed at CalCERTS.com by Justin R Morris (Roper Morris Construction) 4/26/2013 PERFORMANCE CERTIFICATE: Residential Part 3 of 5) CF -1 R Project NameBuilding Type © Single Family ❑ Addition Alone Date Morris Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 4/25/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 2.05 1.96 0.09 Space Cooling 42.61 41.74 0.87 Fans 8.71 10.78 -2.07 Domestic Hot Water 16.63 15.07 1.56 Pumps 0.00 0.00 0.00 Totals 70.00 69.55 0.45 Percent Better Than Standard: 0.6% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 240 48 Fuel Available at Site: Natural Gas (S) 310 70 Raised Floor Area: 0 (tM 300 77 Slab on Grade Area: 1,941 (N) 310 46 Average Ceiling Height: 10.0 Roof 1,941 0 Fenestration Average U -Factor: 0.50 TOTAL: 241 Average SHGC: 0.36 Fenestration/CFA Ratio: 12.4% REMARKS 7 L -G STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Insu-form, Inc. 4)252013 Address 77810 Las Montanas Road, Suite 201 Name .loan D. Hacker City/State/ZipCity/State/Zip Palm Desert Ca 92211 Phone 760-345-1352 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Address Name City/State0p . Phone Signed License # Date EnemvPro 5.1 by EnemySoft User Number. 2655 RunCode. 2013-04-25709:32:51 /D: Pace 3 of 6 Reg: 213-N0024581A-000000000-0000 Registration Date/Time: 2013/04/25 12:35:20 HERS Provider: CalCERTS, Inc Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com - 4/25/2013 Electronically Signed at Ca10ERTS.com by Justin R Morris (Roper Morris Construction) 4/26/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Moms Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Afteration Date 4/25/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Wall 192 0.069 R-21 90 90 New 4.3.1-A6 Whole House Wall 240 0.069 R-21 180 90 New 4.3.1-A6 Whole House Wall 224 0.069 R-21 270 90 New 4.3.1-A6 Whole House Wall 264 0.069 R-21 0 90 New 4.3.1-A6 Whole House Roof 1,941 0.025 R-38 90 0 New 4.2.1-A21 Whole House Slab 1,000 0.730 None 0 180 New 4.4.7-A1 Whole House Slab 941 0.730 None 0 180 New 4.4.7-A1 Whole House FENESTRATION SURFACE DETAILS ID Type Area U -Factor SH C4 Azm Status Glazing Type Location/Comments 1 Window 48.0 0.500 NFRC 0.36 NFRC 90 New IWC 6200 Alumkow-E Whole House 2 Window 20.0 0.500 NFRC 0.36 NFRC 180 New IWC 6200A1um/Low-E Whole House 3 Window 6.0 0.500 NFRC 0.36 NFRC 180 New IWC 6200 Alum/Low-E Whole House 4 Window 20.0 0.500 NFRC 0.36 NFRC 180 New IWC 6200 Alum/Low-E Whole House 5 Window 4.0 0.500 NFRC 0.36 NFRC 180 New IWC 6200A1um/Low-E Whole House 6 Window 8.0 0.500 NFRC 0.36 NFRC 180 New IWC 6200 Alum/Low-E Whole House 7 Window 4.0 0.500 NFRC 0.36 NFRC 180 New IWC 6200 Alum/Low-E Whole House 8 Window 8.0 0.500 NFRC 0.36 NFRC 180 New IWC 6200 Alum/Low-E Whole House 9 Window 40.0 0.500 NFRC 0.36 NFRC 270 New IWC 6200 Alum/Low-E Whole House 10 Window 12.0 0.500 NFRC 0.36 NFRC 270 New IWC 6200 Alum/Low-E Whole House 11 Window 8.0 0.500 NFRC 0.36 NFRC 270 New IWC 6200 Alum/Low-E Whole House 12 Window 16.5 0.500 NFRC 0.36 NFRC 270 New IWC 6200 Alum/Low-E Whole House 13 Window 1.5 0.500 NFRC 0.36 NFRC 0 New IWC 6200 Alum/Low-E Whole House 14 Window 1.5 0.500 NFRC 0.36 NFRC 0 New IWC 6200 Alum/Low-E Whole House 15 Window 1.5 0.500 NFRC 0.36 NFRC 0 New IWC 6200 Alum2ow-E Whole House 16 lWindow 1.5 0.500 NFRC 0.36 NFRC 0 New IWC 6200 Alum/Low-E Whole House (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC T 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t I Wd Ove hang Left Fin Len I H t I LExt RExt Dist Len Right Fin Hot Dist Len Hgt 1 Bug Screen 0.76 8.0 6.0 8.0 0.1 8.0 8.0 2 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 6.0 4.0 2.0 0.1 2.0 2.0 4 Bug Speen 0.76 5.0 4.0 2.0 0.1 2.0 2.0 5 Bug Speen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 6 Bug Speen 0.76 4.0 2.0 2.0 0.1 2.0 2.0 7 Bug Speen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 8 Bug Speen 0.76 4.0 2.0 2.0 0.1 2.0 2.0 9 Bug Speen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 10 Bug Speen 0.76 2.0 6.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 4.0 2.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 5.5 3.0 2.0 0.1 2.0 2.0 13 Bug Speen 0.76 1.5 1.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 1.5 1.0 2.0 0.1 2.0 2.0 15 Bug Speen 0.761.5 1.0 2.0 0.1 2.0 2.0 16 JBug Speen 0.76 1.51 1.0 2.0 0.1 2.0 2.0 EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2013-04-25Tn9:32:51 ID: Page 4 of 6 Reg: 213-N0024581A-000000000-0000 Registration Date/Time: 2013/04/25 12:35:20 HERS Provider: CalCERTS, Inc Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com - 4/25/2013 Electronically Signed at CalCERTS.com by Justin R Morris (Roper Morris Construction) 4/26/2013 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF -1 R Project Name MDf1iS Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 4/2512013 OPAQUE SURFACE DETAILS Surface Ll- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area Ll -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 20.0 0.500 NFRC 0.36 NFRC 0 New IWC 6200 Alum/Low-E Whole House 18 Window 20.0 0.500 NFRC 0.36 NFRC 0 New IWC 6200 Alumkow-E Whole House (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC T 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Right Fin ID Exterior Shade Type SHGC H t Wd Len HqA LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 5.0 4.0 2.0 0.1 2.0 2.0 18 Bug Screen 0.76 5.0 4.0 2.0 0.1 2.0 2.0 EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode. 2013404-25T09:32:51 ID: Page 5 of 6 Reg: 213-N0024581A-000000000-0000 Registration Date/Time: 2013/04/25 12:35:20 HERS Provider: CalCERTS, Inc Electronically Filed by Joan D. Hacker and Authenticated at CalCERTS.com - 4/25/2013 Electronically Signed at CalCERTS.COm by Justin R Morris (Roper Morris Construction) 4/26/2013 c CERTIFICATE OF COMPLIANCE: Residential • (Part 5 of 5) CF -1 R Project Name MORNS Residence Building Type, ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1412512013 BUILDING ZONE INFORMATION System Name Floor Area Zone Name New Existna Altered Removed Volume Year Built Whole House Whole House 1,941 19,410 Totals 1 1,941 01, 01 01 1 HVAC SYSTEMS ' System Name Qty. Heating Type Min. Eff: Cooling Type Min. Eff. Thermostat Type Status Whole House 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback New T HVAC DISTRIBUTION ^'i System Name Duct Heating Cooling Duct Location R -Value Ducts Tested? r Status Whole House Ducted . Ducted Attic, Ceiling Ins, vented 8.0 0 New S. ❑ 13 WATER HEATING SYSTEMS S stem Name Oty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status A. 0. SMITH FPS -50-224 1 Small Gas All Pipes Ins 43,000 50 0.62 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING ControlHP Hot Water Piping Length (ft) o, v a —I S stem Name Pipe Len th Pipe Diameter Insul. Thick. Plenum Outside Buried Ene Pro5.16 Ene User Number. 2655 RunCode: 2013-"25T09:32:51 ID: Page 6 of 6 Reg: 213-N0024581A-000000000-0000 Registration Date/Time: 2013/04/25 12:35:20 HERS Provider: CalCERTS, Inc ppppppp -, Building MateriaIs and Construction Services 45491 Golf Center Parkway, Indio, CA 92203, Telephone:. (760) 347-3332 . Fax: (760) 347-0202 • 'J• .,' ' - .. . , k WY OF LA QUINTA BUILDING & SAFETY'DEPT. -APPROVED • FOR CONSTRUCTION., BY Roper' Morris' 04/03/2013 v W 00 2RE`��®CS 15 14. - .� . � R.12 2013 LA. QuIt4TA CIV 0 vf-Lolp t)E 00 a. f.y � � � �• > . 640600 O d G y W �O CD bq (D vii n C M (TFC+ i N' 0 CD a rpr O ti � a O CO C W. N �q a. G O �t O ao d CD CD ti k3 C/q CD O 0 d CD 0 'O u3 0 O0 W 'CD4 O O +� O O G � G CDD a O O 0 vCDi_ C C w a p CD `d O CD O CD �1'f O N O CCD C CD O CD SCD � C1 CD F CD F N G a O CD CD r� CCD n � CL y, UQ CD 19 rn N C, CD N U .w- CD RCD CD as o O Cy CD cD ti' n CD CDCD -1 a CD O w .2; Lot #7 Ani 4 I 17-00-00 �0 I. + 8-06-00 9-04-00 9 17-00-08 ISI I. 20-08-00 19-04-00 A02 FA , a0 rk B09 4 4 i ' A02 11-05-08 3-09-08 3-11-08 6-05-08 6-11-00 5-07-08 0 •.. _ �. 0 LiAger 200 ,lf ' A02 A02 > 0 4/12 200 pll' A04 ,V 1 B12.. A05 N 'c'') M (7 In A05 15-03-00 0 0 W , W . O W w W w W W w • , A05 81 • - > 112 N B - •'¢-- .Ct. 7..siu _ A05 ti _,- 2W�IfB13' A05 i z B14 — — 0 0 A05 11-05-08 3-09-08 Bt5 24-09-00 Q A05 40-00-00 c v v 816 A05 ... .� TI-(IA26 s2 A05 '' - i. ' 4/12 [ •. �. i 4/12'" A05 .1 ✓ +. •.. 0 TIG37 zla J401 � - ' r ' �; A05 5-07-00 A06 J402 J402 • 130 .ad blks A06 20-04-08 0o 40 Wks 0706 A06 0 0 A07 200 dl' A08 aD q 24-01-00 Gee �✓ o a��a�� g A09 20-08-00 M - 19-04-00 '206 Of B02oo pIF _ 0 19-07-08 A10 B02 003 7-11-00 6-)0-00 > . 6-05-08 A11 200 I,lr C01 C01 08-00-00 B04 o J03 B04 CO2 a o oJ02 CDX,3/12 o 0 B04 aooaoo _ J02A J02J01 B 0 4 200 ,If B / 12-0 2 — J0B05 3/12 ' :. o C✓� B06 e C o 0 G 4/12 4/12 20-0 -00 806 4 0 B06 9-06-00 O TI(IA26 zi -1307.14 B07 200 1l' - 130 .ad Wks 45 Wks @ 0704 B08 2U11 1,11'_ - R blks @ 0908 4 I 17-00-00 �0 I. + 8-06-00 9-04-00 9 o ISI I. 20-08-00 19-04-00 Lot #8 FA , rk B09 4 i ' •.. �. r4- i LiAger 200 ,lf ' > 4/12 ,V 1 B12.. N 'c'') M (7 In 0 0 W , W . O W w W w W W w • , C 81 • - > N B - •'¢-- .Ct. 7..siu _ - ti _,- 2W�IfB13' B14 — — Bt5 0 0 0 c v v 816 ... .� TI-(IA26 s2 '� '' - i. ' 4/12 [ •. �. i 4/12'" .1 ✓ +. •.. 0 TIG37 zla J401 � - ' r ' �; J44 01 —. ,• � © Lts'la za J402 J402 • 130 .ad blks iA 40 Wks 0706 Gee �✓ o a��a�� g 20-08-00 19-04-00 L :1 a N Building Materiels and IN.DIO TRUSS I5-491 Golf Center Pkwy NDIO, CA. 92201 '60-347-3332 Builder :> Job Name :>Morris_Lot 7 & 8 Address :> City :> J403 J401 J402 c✓F ob Number :> ►esigner :>Rocky Carrera ►ate :>3/29/2013 REaAASGTAJRPOUR, P.E. . .TA�?�1�.YI AFT "STRUT a AJ ' Id/iREVIE`fJED ❑ REVISED AND RESUEM-41T- ❑ REJECTED ❑ FURNISH AS CORRECTED Corrections or comments made on the sl;on draw— ings during this review do not relieve contractor from compliance with the requirements of the drawing's: and specifications. This check is only for review ot. general coi:fonnance with the design concept of the project and general compliance with the info.=.nation;: given in the contract documents. The cont-ractor is tespor_sible, for confirming and correlating all 1i:an- lities and dimensions; sw;ecting fabricat"'on proces es. and t^chniqueg of constniction; ccardinacin. his Work with that of all other trades; and perforinin itl§ work in a safe satisfactory / marmer. Y_ Aatc �i -r! _3 :'J". 40 POST IN A CONSPICUOUS PLACE Certificate of Occupancy Community Development Department This Certificate is issued pursuant to the requirements of Chapter 1 Section R110 of the California Residential Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 53-385 AVENIDA MENDOZA Use classification: SINGLE FAMILY DWELLING Building Permit No.: 13-0338 Occupancy Group: R-3 Type of Construction: VB Land Use Zone: RC Code Edition: 2010 Sprinkler Installed: YES Sprinkler Required: YES Owner of Building: ROPER PROPERTIES LLC Address: 50855 WASHINGTON ST C216 City, ST, ZIP: LA QUINTA, CA 92253 ____________ GREG BUTLER_________________ By: KIRK KIRKLAND Building Official Date: JANUARY 24, 2014