Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
SFD (04494)
Building 53-42S MerldoZa Address Owner Paul I -lots Mailing Address V. 0 Port AA4A City Zip Tel. 92261 Palm Desert Contractor Address IZip I Tel. State Lic. I City & Classif. Lic. # Arch., Engr., Designer Address Tel. P.O. BOX 1504 78-105 CALLE ESTADO LA QUINTA, CALIFORNIA 92253 CityI Zip I State Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) t.of Division 3 of the Business and Professions Code, and my license is in full force and effec SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to rile a signed statement that he is licensed pursuant to .the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he Is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). O I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) ❑ I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Y' Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company O Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that In the performance of Ing work for which this permit is issued, 1 shall not employ any Person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, alter making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration If work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree -to comply with all city and county ordinances and state laws relating to building constnictioh, and hereby authorize representatives -of this city to enter the above- mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip 04494 t BUILDING: TYPE CONST. OCC. GRP. A.P. Number Legal Description Project Description S.F IDI 0 Sq. Ft. 1360 No. No. Dw. Size Stories Units New ❑ Add ❑ Alter ❑ Repair'❑ Demolition ❑ Estimated Valuation $74040 40 PERMIT AMOUNT Plan Chk. Dep. $2SO.00 Plan Chk. Bal. $ 56 s D Const. 35e.00 Mech. 36.0 Electrical 63.00 Plumbing 103.00 S.M.I. 5.22 Grading 20.00 Driveway Enc. 204.00 Infrastructure 20630. 00 TOTAL $2,541.22 <`.. Y11 , REMARKS ` ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE -INSPECTOR Issued by: Date Permit Validated by: Validation: 1 WHITE - FINANCE, PINK - APPLICANT, GREEN - BUILDING, GOLDENROD - ASSESSOR'S OFFICE, HARD COPY - FILE CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES ISI FL SO Fl (p $ UNITS ' 2ND FL SO FL g BONDING YARD SPKLR SYSTEM STORAGE TANK MOBILEHOME SVC. BAR SINK POR SO FT a DUCT WORK ROCK STORAGE GAR SO. FT. 0 POWER OUTLET ROOF DRAINS HEATING (FINAL) OTHER APP.IEOUIP. DRAINAGE PIPING CAR P. I SO FT. a TEMP. POLE WALL SO. FT. a GROUT DRINKING FOUNTAIN SO. FT. fd FINAL INSP. URINAL ESTIMATED CONSTRUCTION VALUATION $ WATER SYSTEM WATER PIPING NOTE' Not to be used as property tax valuation -$ FLOOR DRAIN MECHANICAL FEES FINAL INSP. WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASH ER(AUTO)(DISH) APPLIANCE DRYER GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED VENTILATION LAUNDRYTRAY AIR HANDLING UNIT CFM KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET COMPRESSOR HP POLE, TEMIPERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SO. FT. ® c BATH TUB SO. FT. @ c WATER HEATER MAX. HEATER OUTPUT. B.T.U. SO. FT. RESID C 11A c SEWAGE DISPOSAL SO.FT.GAR (& >r:c HOUSE SEWER INSULATIONISOUND GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB FEE STRUCTURE PLUMBING ELECTRICAL HEATING 8 AIR COND. SOLAR SETBACK ROUND PLUMBI - UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER OR SEPTIC TANK ROUGH WIRING DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APP.IEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu. yd. $ plus x$ -$ LUMBER GR. FINAL INSP. FRAMING FINAL INSP. ROOFING %� i /L �✓ , / /ti -- ! ��;/i �i` REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL Ll THING/6 MESH INSULATIONISOUND FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURESlINITIALS GARDEN WALL FINAL Desert Sands Unified School District CERTIFICATION OF PAYMENT OF SA �"f�SCHOOL., FACILITY FEES iC1�J (-' 10 1z aUy TO: City of La Quinta DATE: atarj Department of Community Development 78-105 Calle Estado La Quinta, CA 92253 This is to certify that (( :2 developer of which is located at CL. within this District, has paid school facili fees imposed pursuant to the authority generate by Government C de Section 53080 in he amount of covering a total of squ re fe t of (A) residential or ( ) industrial/commercial development and that building permits for this footage in this development may now be issued by your jurisdiction. (�fx;v) 1-)c . Amx Ifor ESERT SA S UNIFIED SCHOOL DISTRICT White - Building Department • Yellow - Facilities Planning • Pink - Accounting • Gold - Developer (10)-37 COUNTY OF RIVERSIDE, DEPARTMENT OF HEALTH ENVIRONMENTAL HEALTH SERVICES DIVISION — — PERMIT APPLICATION FOR A SUBSURFACE SEWAGE DISPOSAL SYSTEM Applicant: Submit this form with four copies of a scaled plot plan (1.20 scale) drawn to County specifications required on the attached check list. A non-refundable filing fee of $40.is required when the application is submitted. Check must be made payable to the County of Riverside. Building Department Application Log # Name (Owner. Agent. Contractor. Etc.) Mailing Address favi G - MOSS -�n. Qox City Slate Zip Code Telephone ?A�,YK 7E, .rlT CA - 922L61 1 3qb - {931 'Job Property Address 'City o rommunity-.-_ 'Legal Description of Property. (Lot. PM. TR) I 41 M Fro D o A A Q v I M A Lc5 ( Cl A NrR (A&ffif-t (TA 'Assessor's Parcel No wz Agency aWdl-- /j�/r' ��,,�,/ �! ' �F Permit kF :YJ l� GLti/ �/�rPlaAri (Cot [& e & v, - I. Use of ng Case M ® So'K too 1 C V . W p SFO. MH Site Preparation Etc Signature of Applicant Dale 'The above information must be verified from Building Application STAFF USE — DO NOT WRITE BELOW THIS LINE ,"Initial Date Certification of Existing S.D. System required. ❑ Yes �,r�_Ct WOCB Clearance required. El Yes p` No,` f r Soils feasibility report required. El Yes Special feasibility boring report required. ❑ Yes � Detailed contour plot plans required. ❑ Yes 25 No'- Staff Specialist approval. -required. ❑ Yes sE No Lot Inspection Date Soils/boring report b��y���� lC�, I �1 Project # Date Soils Map Pageai t r Soil Type �` Approved by Date l/1t F� ` Type of System: V No. of Bedrooms (1) Septic Tank Soil Rate Required El Existing CKew El Additional El Replacement d'y° l Gals. (2) Leach line sq. ft. �renchea) Sidewall allowance ft. rock/ Sq. Ft. Install Lines) Ft. Long. Ft. wl a in. inches Lea r -ed ISq. Ft. of bottom per running ft. C9,<A rock below drain lines area Leach lines/bed•special design for slope: Applicable f (3) Pit Diameter No. Pits Pit BI/ Seepage Pit total depth �� / N/A � Overburden factor — Max. allowable depth �U This application is proved rued for the design of a subsurface disposal system as indicated on the accompanied plot plan using the requirements set forth in Section B a ove. A building permit is netgssary for the installation off, the above-de`vgn ms kem 1 (1) Septic tank and sewer lines must be 50'bfrom any WOv.� j 0f�/ Si wells ('" !,(� •� (2) Leach lines must be 100' min. from any wells including expaion r a �Seepage pits must be 1150' mi`n/from any"welIs including expr nsioh area c� 7/' C.�i/. /C.. G2e?�!'Gw •ti r%� i `{� GLIz>e- �ixv d cS� Signature of Health Official Y �- tel RECEIPT NO. -3 9I Sr District: ❑ Riverside ©4n io ❑ Hemet Distribution: WHITE—Office file DOH -SAN -122 (Rev. 4188) Issued by 4 Da e ❑ Perris ❑ Rancho Calif. ❑ Blythe YELLOW—Applicant PINK—Bldg. Dept. GOLDENROD—Pending File OF R { y� o;,�� OFFICE OF E. LEON SPAUGY Q �� s AGRICULTURAL CU.AMISSIONER COMMISSIONER JAMES O WALLACE o c AN D . ASS:S*.ANt COMMISSIO%EP. WEIGF"I1,S & MEASURES CLEMEVT BE`VENISTE SEALER. - - 49-613 Hwy 86, Suite B-1.2 ���„,��.•'� Coachella, CA 92236 Sq 619-342-8291 DATE � � I (Ci 0 0 CASE NO . 2 �� Lr IG� b � 6 . DEVELOPER'S NAME- Pawl ` V /C L)S' ADDRESS: �� q iC K6S EtiJ>4 ^ . �Ar�vt.� I.1SiJFG✓� l �/� TELEPHONE: (6 g ) 3 o _ �3 Dear Developers After reviewing your landscaping plans, all plant material listed is not in .violation of quarantine laws governing the Coachella Valley. If substitutions do occur and they differ from plant material. listed, this office must be notified immediately. Thank you for protecting and preserving the Coachella Valley's pest-free environment. ” Agr6buitural CctFmissioner's Office cc: Indio and Riverside Office POINT SYSTEM SUMMARY -CLI MATE l ONE 15 P -2R PROJECT TITLE=TAMCO DEVELOPMENT x DAl"E=8-14-88 JOB SITE=L_OT 10 / LA QUINTA BUILDING DATA ' CONDITIONED FLOOR AREA= 1465 NUMBER OF STORIES=.l SLAB/RAISED FLOOR SLAB' TOTAL. GLASS AREA 171 ,SQ. FT !GLASS 11.67236 CHECK ALL APPLICABLE UNIT TYPE CONDITION (S ) (X), SINGLE FAMILY DETACHED (SFD) ( )-,ADDITION ALONE ' ( > SINGLE FAMILY ATTACHED (SFA) ( )'EXISTING BUILDING f ) MULTI—FAMILY (MF) (`) EXIST'ING—PLUS—ADDITION SCORE CARD ' MEASURES • POINT SCORES. 1. CE I L I NG I NSU a �8 0 20 WALL INSUa 19 0 _e RAISED FLOOR INSU_ 0 0 4 o SLAB EDGE J NSU 0. .c) 5o INFILTRATIONSTANDARD o 6o GLASS HEAT LOSS DOUBLE'PANE U=a65 5 SUM 1-6= ( J ) 7a SHADING (SHADE OPEN) GLASS AREA . SC= 06776 A. NORTH026 Be EAST 0 19 ' D. SOUTH 0 40 E. WEST 1 86 Ha SKYLIGHT 0 0 Ho SHADING (SHADE CLOSED) % GLASS SC= 2552 A. NORTH G '10774744 B. EAST - u 10296928 C. SOUTH 4: 2.730375 D. WEST C) 5.870307 E. Sk: YL -I GHT SC= O e,77 f t . 9. INTERIOR THERMAL MASS 10788._.96 —1 10.EXTERIOR WALL,MASS 0 o SUM:; 7-10 = ( 7 ) I I. HEATING' SYSTEM 72 S.E. G 1 o COOLING SYSTEM 9.100001 SEER —4 , 13 WATER'HEATING S.G. 0 ` t TOTAL'`POINTS 8 r JOHN H. HACKER, , CIVIL•ENGINEER, PALM SPRINGS 327-4565 i• " i A Y i NAME -- ---- TAMCO DEVELOPMENT ADDRESS ---- LOT 10 / LA QUINTA DATE --- – 8-14-88 -REF.CAL.ENERGY CONSERVATION DESIGN MANUAL, FORM-2, HEATING LOSSES MANUAL J FOR-COOLING LOSSES AREA BLDG 1465 SO. FT. ' PERIMETER 16207778 SO. FT. INSULATION R'VALUES °FLOOR 0 ..CEILING 38 ..WALL 19 -AREA NORTH WINDOWS, 6 SO o r'T o PERCENT OF AREA 1.7:/4744 AREA*EAST WINDOWS 19 SOoFT. PERCENT OF AREA 1.29.6928 AREA SOUTH WINDOWS 40 SO n' FT o PERCENT OF .AREA 2.73"0375, AREA WEST WINDOWS 86, SO FT 4 • ' PERCENT OF AREA 5.87C)3(.-)7 AREA SKYLIGHTS 0 SD. FT PERCENTOF AREA 0 TOTAL WINDOW ;AREA 171 SO.FT. PERCENT OF AREA 11 0 672;:6• i THE U VALUE OF THE-WINDOWS IS .65 DUAL PANE THIS BLDG USES DRAPES &'FLAT SHADING DEVICES* ON WINDOWS (*mini.–blinds, rallar shades, venetian blinds or ver••ti>csl blinds) THE TOTAL S a C. ' OF THE WINDOWS IS 0.30 SOUTH OVERHANG LENGTH 2 INTERIOR THERMAL MASS AREA = 262 SO FT. INFILTRATION (STD 0.018, MED 0.014, TIGHT 0.012) = .018 HEATING LOSSES FOOTING LOSSES... '5046.111 BTU CEILING LOSSES,—. 1149.747 RTU WINDOW-LOSSES.. 3445.65 BTU WALL LOSSES.... 17100629 RTU .INFILTRATION LOSSES... 6539.76 BTU TOTAL HEAT LOSSES BTU/HR.. 178910,9 GAS FURNANCE SIZE 37909.47 'BTU OR 45,000 BTU COOLING LOSSES FOOTING-LOSSES... 2170°.37 BTU CEILING LOSSES... 1483.544 BTU WINDOW LOSSES... 6645 BTU WALL LOSSES.o<0 2207.263 BTU INFILTRATION LOSSES... 281208 BTU NO. OF PEOPLE... 5 COOLING LOSSES... 2010 KITCHEN... 1500 BTU DUCT LOSSES INCLUDED IN .TOTAL TOTAL CODLING LOSSES 24444058 RTU t Mandatory. Measures Checklist: Residential MF -1R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance r approach used. Items marked with an asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum "component performance specifications for the mandatory measures " whether they are shown elsewhere in the documents or on this checklist only. . DESCRIPTION DESIGNER ENFORCEMENT Building Envelope Measures • 12-5352(a):. Minim' n ceiling insulation R-19 weighted average. 12.5352(b): Loose fill insulation manufacturer's labeled R=Value. • 12-5352(c): Minimum wall insulation in framed walls R-11' weightedaverage (does not apply to exterior mass walls). 12.5352(k):. Slab edge'insulation - water absorption rate no greater than 0.3%, water vapor N/ . transmission rate no greater than 2.0 perm/inch. , r . 12-5311, Insulation specified or installed meets California Energy Commission (CEC) quality r standards. Indicate type and form. 12-5352(f): Vapor barriers mandatory in Climate Zones 14 and 16 only.. 4 N 12-5317: IifiltiafioNExfiltration Controls ` L Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. / b. Doors and windows certified: I /~ c. Doors and windows weatherstripped; all joints•and penetrations caulked and sealed VVV .12-5352(e): Special infiltration barrier installed to comply with 12-5351 meets CEC quality .' standards, -. • • 4 .. , 12-5352(d): Installation of Fireplaces ` 1. Masonry and factory -built fireplaces have: a. Tight fitting. closeable metal or glass door b. Outside air intake with damper and control + _ c. Flue damper and control 2. No continuous burning gas pilots allowed. - HVAC and Plumbing System Measures. 12-5352(8) and 2-5303: Space conditioning equipment sizing: attach calculations. , ' - . 112-5352(h) and 2-5315: Setback terhmostat on all applicable heating systems. ' ' 12-5316(a): Ducts constructed, installed and insulated per Chapter 10.1976 UMC. 12-5316(b): Exhaust systems have damper controls.' ' "12-5314(c): Gas -fined space heating equipment has intermittent ignition devices. 12-5314:.HVAC equipment, water heaters. showerheads and faucets certified by the CEC: §2-5352(1): Water heater insulation blanket (R-12 or greater) o'r combined interior/exterior insulation (R-16 or greater); fist 5 feet of pipes closest to tank insulated (R-3 or greater); 12-5312(Exception 1): Pipe insulation on steam and steam condensate return do recirculating , . piping. 12-5318(d): Swimming Pool Heating 1. System has: a. On/off switch on heater. . b. Weath f instruction plate on heater. , e�proo r c. Plumbed to allow for solar. r- , 2. 75 percent thermal efficiency. y _ 3. Pool cover' 'r 4. Time clock. ` 5. Directional water inlet. Lighting and Appliance Measures ' ...12-53520): Lighting- 25 lumens/watt or greater for general lighting in kitchens and bathrooms. 12-5314(c): Gas fired appliances equipped with intenmittuu ignition devices. 12-5314(a): Refrigerators, refrigerator -freezers, freezeis and fluorescent lamp ballasts certified by the CEC. Indicate make and model number. Pam Revived Deomnbw 198.7