Loading...
RER (07-1624)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 T,iht 4 4 Q" Application Number: 07-00001624, Property Address: 78855 MERIDIAN WY APN: 609-480-063-17 --23773 - Application description: REMODEL - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 6000 Applicant: Architect or Engineer: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT ----------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: _ License No.: Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the . permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant fora permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( rl I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(sl licensed pursuant to the Contractors' State License L (_ 1 I am exempt under Sec. IE iP.-_ . for this reason v NSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: CQPERA7IT Owner: ADAMS DAVID *NOT ON FILE UNKNOWN, CA 99999 Other struct info Contractor: Owner DITION VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 6/20/07 C D Q 0 CSC JUN 212007 CITY OF LA AUINTA FINAL i9rPT WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier - - - - - - - - - - - - - - - - .-- - - - -- Policy Number I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any man so as to become subject to the workers' compensation laws of California, and agree that, j I sho Id becomes nsation provisions of Section 13700 of the Cod foFstkwitllcomply with those prove WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agentZand loyees omission related to the work being performed under or following istis permit.2. Any permit issued•as a result ofation becomes null and void if work is no mencedwithin 180 days from date of isuch permit, or cessation of work for 180 day 'll subject permit to cancellation. I certify that I have read this application and the bove information is correct. I agree to comply ith all city and c my or 'nances and state laws reuild g nstruction, and hereby authorize repres tives ofcnty tto upon the above-mentert sp ion purposes. ate: ignature (Applicant or Application Number . . . . . 07-00001624 Permit . . . BUILDING.PERMIT Additional desc . Permit Fee 81.00 Plan Check Fee 52.65 Issue Date Valuation . . . . 6000 Expiration Date . 12/17/07 Qty Unit Charge Per Extension BASE FEE 45.00 4.00 9.0000 ---------------------------------------------------------------------------- THOU BLDG 2,001-25,000 36.00 Permit ELECT - ADD/ALT/REM Additional desc Permit Fee . . 25.50 Plan Check Fee 6.38 Issue Date . . . . Valuation 0 Expiration Date 12/17/07 Qty Unit Charge Per Extension. BASE FEE 15.00 14.00 .7500 ---------------------------------------------------------------------------- PER ELEC DEVICE/FIXTURE 1ST 20 10.50 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 19.50 Plan Check Fee 4.88 Issue Date Valuation . . 0 Expiration Date 12/17/07 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 ---------------------------------------------------------------------------- Special Notes and Comments 3rd CAR CONVERSION TO BEDROOM PER APPROVED PLANS --------------------.-------------------------------------------------------- Other Fees . . . . . . . . . ENERGY REVIEW FEE 5.27 STRONG MOTION (SMI) - RES .60 Fee summary Charged --------------------------- Paid ---------- Credited -------------------- Due Permit Fee Total 126.00 .00 .00 126.00 Plan Check Total 63.91 .00 .00 63.91 Other Fee Total 5.87 .00 .00 5.87 Grand Total 195.78 .00 .00 195.78 LQPERAIIT BInA City of La Quinta Building U Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building .Permit Application and Tracking Sheet Permit # 077--1 2 Project Address: s�. i i(1pt� Owner's Nam �yY`S A. P. Number: , Address:7<6-%3 S rY-\24-,, Legal Description: Contractor: City, ST, Zip: Telephone: Project Description: Address: City, ST, Zip: C-0 Telephone: State Lie. # : City Lic. #: Arch., Engr., Designer: Address: • City, ST, Zip: Telephone: State Lic. #: Name of Contact Person. �1 Cons tion y e: Occupancy: Project pe (circle one): New Add'n ter Repair Demo Sq• pt„ AO # ories: # Units: Telephone # of Contact Person: . Estimated Value of Proie G APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING . PERMIT FEES Plan Sets Plan Check submitted 6, Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Calcs. Plans picked up Construction JAL Je Flood plaigplan Plans resubmitted Mechanical fi Grading. plan 20° Review, ready for correctionslissue Electrical 3 Subcontactor List Called Contact Person Plumbing �. Grant Deed Plans picked up S.M.I.. H.O.A. Approval Plans resubmitted Grading IN HOUSE: 3' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person Pub. Wks. Appr Date of permit issue Af School Fees Total Permit Fees (off l �wwra Date 6/20/07 No. 29532 Owner David Adams CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 APN # q�'S��scyo Q 9ERMUDA OUNES r rn RANCHO MIRAGE INDIAN WELLS PALM DESERT y LA QUINTA INDIO %y� O 609-480-063 Address 78-855 Meridian Wy Jurisdiction La Quinta City La Quinta Zip 92253 Permit # Tract # Study Area Type Residential Addition No. of Units Lot # No. Street Unit 1 78855 Meridian Wy Unit 2 Unit 3 Unit 4 Unit 5 Comments 3rd Car Conversion to Bedroom S.F. 203 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 Lot# No. Street S.F. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 203 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - BJ Adams Check No. Name on the check Telephone 272.7953 Funding Exempt By Dr. Doris Wilson Superintendent Fee collected /exempted by on vrey Payment Recd O p -�; <Over/Unifier' Signature 4,,r, NOTICE: Pursuant to Government Code Section 66020(d)(1tthJillserve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting >< 1 TITLE 24 REPORT Title 24 Report for: "- 1 Project Designer: Jorge L. Garcia 75-1.53 Merle Drive - Suite B Palm Desert, CA 92211 760.272.9222 Report Prepared By: SLO Santiago Lopez-Ocampo P.O. Box 1018 La Quinta, CA 92247 (760) 485-8927 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE �- °7 BY S,�f F:JUNJob Num12007 D t" 9wLc-- The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.1 by EnergySoft Job Number. Ig050406 User Number: 5732 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary 1 2 3 6 8 EnergyPro 4.1 by EnergySoft Job Number. Ig050406 User Number. 5732 0 Certificate Of Compliance : Residential (Part 1 of 3) CF -1 R Project i me 5 Date /412006 Project Auu.... Building Permit # Santiaan I nnP7-QrgmYln (760) 485-8927 Documen tlon Author Telephone Plan Check/Date Fne-MVPro 15Field Check/Date Compll nce method Climate Zone TDV Energ Use Standard Proposed Compliance (kBtu/sf-yrr Design Design Margin .Space Heating 0.35 0.32 0.03 Space Cooling 123.75 120.78 2.98 Fans 17.41 16.95 0.46 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 141.51 138.04 3.47 Percent better than Standard: 9 1;%. Building Type: Y Single Family Q Addition Total Conditioned Floor Area: 210 ft2 ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (S) 180 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 210 ft2 Fenestration: Average Ceiling Height: 8.0 ft Area: 25 ft2 Avg. U: 0.65 Number of Dwelling Units: 0.65 Ratio: 11.9% Avg. SHGC: 0.40 Number of Stories: 1 BUILDING ZONE INFORMATION. # of Thermostat Vent Zone NameFloor Area Volume Units Zone Type Type 11VAr Syctam FYictLg) 21n 168 n a5 Conrlijinngrl Setha Ck— Hgt. Area —2 n1a OPAQUE SURFACES Insulation Act. Gains Condition Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y / N Status JA IV Reference Location / Comments Rnnf Wnnd 210 n 095 R-319 R -n n dig ® New M -AIR Additinn Wall Wnnd �]� R-11 RR -0.0 1Rn gn ® New D9 -A3 Ronm Additinn Wall Wnnd 161 0 102 R-13 R_n n 270 90 ® New 09-A3 B00m �m_Addition Run Initiation Time: 05/04106 09.35.29 Run Code: 1146760529 EnergyPro 4.1 by Energysoft User Number. 5732 Job Number. Ig050406 Paae: 3 of 8 Certificate Of Compliance: Residential (Part 2 of 3) CF -1 R C Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazing Type Comments .1_ Window Front ( 25 0 a 950 NFR(: n_an NFgr 1H0 __qp-NPw U-ValiiP & . G DPcignPr }doom Addition 1. Indicate source either from NFRC or Table 116A 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 5.0 5.0 2.3 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Run Initiation Time: 05/04/06 09.35.29 Run Code: 1146760529 EnergyPro 4.1 by EnergySoft User Number. 5732 Job Number. Ig050406 Page:4 of 8 Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Insulation PERIMETER LOSSES Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 31 None No Insulation 26-A1 New Room Addition Run Initiation Time: 05/04/06 09.35.29 Run Code: 1146760529 EnergyPro 4.1 by EnergySoft User Number. 5732 Job Number. Ig050406 Page:4 of 8 Certificate Of Compliance: Residential (Part 3 of 3) CF -1 R Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC System ( Existinq) Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Existing Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC System ( Existing) Ducted Ducted Attic 4.2 Existing No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Ratedl Tank Energy Standbyl Tank Insul. Water Heater # in Input Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (al) Status or RE 1 (%) Ext Multi -Family Central Water Heating Details Hot Water Pump _Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: SLO Title/Firm: Jorge L. Garcia Title/Firm: Santiago Lopez-Ocampo Address: 75-153 Merle Drive - Suite B Address: P.O. Box 1018 Palm Desert. CA 92211 La Quinta, CA 92247 Telephone: 760.27 .9 22 Telephone: (760) 485-8927 Lic. #: (signature) (date) (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 1818 or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ reductions in the cross-sectional area of the ducts. § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑ ❑ 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ❑ ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ❑ ❑ luminaire has factory installed HID ballast. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑ ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages, laundry rooms, and utility rooms be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are El ❑X El 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ retardant and provides shielding from solar radiation that can cause degradation of the material. 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). 7. Flexible ducts cannot have porous inner cores. ❑ ❑ ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages, laundry rooms, and utility rooms be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are El ❑X El controlled by an occupant sensor that complies with Section 1'19(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ X❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.1 by EnergySoft User Number: 5732 Job Number: Ig050406 Page:7 of 8 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE SYSTEM NAME HVAC System Existing) FLOOR AREA 210 CHEC Number of Systems 1 Heating System Output per System 0 Total Output (Btuh) 0 Output (Btuh/sqft) 0.0 Cooling System Output per System 1 Total Output (Btuh) 1 Total Output (Tons) 0.0 Total Output (Btuh/sgft) • 0.0 Total Output (sgft/Ton) 520,000.0 Air System CFM per System 0 Airflow (cfm) 0 Airflow (cfm/sgft) 0.00 Airflow (cfm/Ton) 0.0 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 190 4,659 616 88 3,755 110.OoF 0 Supply Air Ducts 936 538 0 0 0 0 0 0 0 0 Heating Coil 0 936 538 6,532T77616 Default FAU/AC 1992 - 2005 1 0 Total Adjusted System Output 1 0 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm 4 831 0 Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 70.0 OF 110.OoF Supply Air Ducts Outside Air 0 cfm 110.00F Heating Coil ROOMS 70.0 of 70.0 of Return Air Ducts I COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6 OF 78.0/62.3 OF 55.0/53.7 OF Supply Air Ducts Outside Air 0 cfm Cooling Coil 55.0 / 53.7 of ROOMS 41.2% R.H. of 78.0 / 62.2 of 78.0/62.2 Return Air Ducts I EnergyPro 4.1 by EnergySoft User Number. 5732 Job Number. Ig050406 Page:8 of 8