Loading...
9603-102 (AR)y - LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date o841W B ' 3/31 r o Date _ Signature of Contractor (7 OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ( ) I am exempt under Section , B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is;issued* Myllvporkers' compensation insurance carrier{&9Wjpy no. are: Carrier Policy No. (This section need not be completed if the permit valuation is for $100.00 or less")'., •- ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree/..that if I should become subject to they'Orkers' compensation provisions�of Section 3700/6f the Labor CodeIs all f6 hwith comply with t o e prow Ions. Date:' Applicant ' Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property J inspection.,purposes: Signature (Owner/Agent) Date t-/( BUILDING PERMIT PERMIT# - CONTROL# 19ill~3-102 3010 DATE y2sm VALUATION S2` x12. LOT TRACT JOB SITE ADDRESS �.rt1w M MON APN 741-"14M OWNER CONTRACTOR / DESIGNER / ENGINEER LOUISA SYLVIA EISEN BERG BOB EDWARDS CONSI'RUMON :iow3 MERTON Na -920 RUM DRIVE LA QUWA C,'1 02253 LA (XOINTA ('A 92253 (619)775_793; CHL# 3212 USE'OF PERMIT Al 114 1*10N A&i 161 xq li of vast _arrsege and 287 oq ft of e. CUSTOM C4L)N81_RLl('TI0N 281.00 SF 1:3AliA.tWA*ARr10R I' 16i 00 :31: t E.STIMA'1'm C'+(.AST OF CONSTRUCHON 25,512." IRMMIT 611,E S1IMMARY PLAN (IIFX % FFF 101-000-4:W-318 5214.52 _ C(:rN_ST1tL'( r10N KE 101-440-418-000 $258.50 I► XII NIC;A.i. FEE 101-000421-000 539.30 CIO FLFit-MICAL FIX. I0I-000-4204M S31 27 cr) CID Pi.i IM114 iil FEE 101 •-000-419-(lia() $010) S• oNo 14fCmoN FTS - '101-000-2.11-000 $255 C31Z,iI)ING FFiS 101-ODU-42.1•000 120.00 O cr NF'R ASTK1 kn TR P. H-1-, 225 -WO -44-4- 442 $574.04 a. m SUB-IVFAI. CONSi'RC,k-"i ON AND PLAN CHECK SI,1RiI.3R LESS IRE -PAID FEES $0.00 TOTAL P1P RMI F IC' ERSi MIX NOW t1,in.38 RECEIPT DATE BY DATE FINALED INSPECTOR INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING`APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Foulings Ducts Slab Grade Return Air Steel . Combustion Air Roof Deck Exhaust Fans O.K to Wrap F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wali Insulation-jru4KX Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final BLOCKWALL A P OVALS POOLS - SPAS steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final I I Gas Piping PLUMBING Af/fo,VALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring. Low Voltage Wiring Fbdures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: Notice: Document Cannot Be Duplicated Date " 3/25/96 No. 14292 Desert Sands Unified School District 82-879 Highway 111 Indio, CA 92201 619-775-3500 CERTIFICATE OF COMPLIANCE Owner Name Louis & Sylvia Eisenberry No. 56665 City La Quinta Tract # Street Merion Lot # APN # Jurisdiction La Quinta zip 92283 Permit # Log # Study Area 106 Square Footage 448 Type of Development Residential Addition No. of Units 1 Comments By 3ersonal office and golf cart garage At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 0.00 X 448 or $ 0.00 the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By N/ATele phonea- 775- 933 - Name on the check F Dolores A. Ballesteros %+, '' ''',; Superintendent Fee collected /exempted by Pauline Pearson Exempt $0.00 Check No. N/A Signature ,� Q, AA 2,:A�A�yN. Collector: Attach a copy of county or city plan check application form to district copy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting MAR -10-96 SUIS 11 1 AIL t ()NAPCH GRGUp Rct NO. .619 360 411E p 1 PGA WEST H RESIDENTIAL ASSOCIATION, INC. March 8, 1996 P.O. Box 1282 • La Quinta, CA 92253 Louis & Silvia Eisenberg 56-665 Merion La Quinta CA 92253 Re: Architectural Variance Request - 56-665 Merion Dear Mr. &.Mrs. Eisenberg: Thant; you for your request to construct an office and cart garage at the above -referenced address at PGA West. The plans submitted were approved, subject to the following conditions: 1) Plans and Specifications for the office and cart garage comply with all applicable La Quinta building codes/safety ordinances 2) A small portion of your driveway may be scheduled for replacement by Sunrise Company, as part of their settlement on replacement of certain concrete flatwork in PGA West II Residential Association. You will be notified by the Association within the next 90 days if any portion of the concrete flatwork around your unit is affected. You may, however, proceed with this project: 3) Please note the,following conditions of approval of the landscape plans, a. Owner shall be responsible to replace euryops and Mediterranean fan palm should they perish in the future. b. Moraia (M1) proposed is not peniiitt.ed—replace with day filly. c. Owner must supply annual color to match -HOA planting.scheme on front yard and north property line as indicated on plan, each year. d. Any pool fencing damaged in construction must be replaced on an as -like basis, including painting. e.. Provide a sample of La Cresta boulderrp for to purchase and installation for review and approval by the Committee. Please review front yard boulders at McCallum residence (56-690 Merion) for approv4size and locations. La Cresta boulders must be similar in size and exhibit similar brown tones. f.. Owner responsible to replace with like size the transplanted Queen palm. (Cocos Pumosa) if it dies after transplanting, 1 lknonarch�users\john�pgares2�cisenberg arch. approval 3.9.96.doc 1V AIYI ln!+1'lniA':n 'iv. 'I rP,R No. 619 360 4160 1' LOUIS & Sl'LVIA EISENBERG MARCH 8, 1996 PAGE TWO CONDITIONS OF APPROVALICONT.) g. Provide a sample prior to purchase and installation of the border brick proposed in the driveway. Both the Board and -Architectural Committee are pleased with the'room. additions proposed on your plans. Please note that any exterior change orders to that which is depicted on these plans must first be submitted to the Architectural Committee for their approval, prior to the work commencing. We look forward to the finished product, and should your contractor have any questions, he may contact our property manager John Handel at 360-4161. Sincerely; PGA WEST II RESIDENTIAL ASSOCIATION Don Troy, Chairman Architectural Committee M. Board of Directors John Handel, The Monarch Group d:ljohnNppm2leisenberg arch. approval 3.8.96.doe TITLE 24 REPORT'FOR: Eisenberg Residence -Office Addition 56-665 Merion' Ofwe j,,/ 3( Q6 �•, La Quinta,. Ca `. PROJECT DESIGNER: Robert A. Pitchford, Design & Drafting 79-370 St Lucia.Ct. Dermuda,Dunes, Ca 92201 ( 619) 360-1657 REPORT PREPARED BY: _ Tim Scott BREEZE AIR CONDITIONING 75'145 ST .CHARLES PLACE' PALM DESERT, CA 92260 ( 619) 346-0855. Job Number: Date: 3/11/1996 The COMPLY 24 computer program has been used to perform the calculations summarized in this compliance.report. This program has approval and is authorized by the California Energy Commission for.use with both the • Re'sidential and Nonresidential Building Energy Efficiency Standards. This/program-developed by Gabel Dodd Associates - ( 510) 428-0803. . J l' Table Of Contents for Title 24 Report Cover Page ... .......................... ................. .... 1 Table'of.Contents ............................:.............:... 2 Form CF-1R'Certificate of Compliance ....... .......:. ......... ... 3 Form MF-1R Mandatory Measures Checklist .. .................. ...... 5 Form P-2R Point System Summary .........................7.... ........ 7 .Form C-2R Computer Method Summary (Points) .................... .... 8 Form ENV-3 Construction Assemblies ........ ........................ 11 HVAC System Loads Summary .......... ............ ................. 15 Zone Heating Loads Summary ...................................... 1 16 Zone Cooling Loads Summary .:........................ ............. 17 HVAC Equipment Specifications.....:..................................18 Form CF=6R Installation Certificate ................................ 25 i u CERTIFICATE OF COMPLIANCE - Residential ( part 1 .of 2 ) CF -1R page 3 of 25 Project Name: Eisenberg Residence -Office Additio n .;Date: 3/11/1996 Address: 56-665-Merion La,Quinta, Ca ;Building Permit No Designer: Robert A. Pitchford,�Design & Drafting ;Checked by./ Date Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665 --------------------------------------------------------------------------- GENERAL INFORMATION Compliance Method: Climate Zone: Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Floor Construction Type: BUILDING SHELL INSULATION Component --------------------- R-21 Wall '( W.21 .2x6 .16 ) Solid Wood Door R-38 Roof(R.38.2xl4.16) Slab Perimeter w/R-0.0 COMPLY 24 version 5.00, .15 287 sqft Single Fam Det 180 deg, ( S ) 1 Slab on Grade U -Value Location/Comments 0.059 Office Addition 0.387 Office Addition 0.029 Office Addition 0.900 Office Addition FENESTRATION Shading Devices Frame Orient. Area. -- ----- ------ U-Va.l ----- Type ------ Interior Exterior ------------ OH SF Type - Right ( E ) 3.5 0..72 Double ------- none none ------ -- Y -- 'N. ----- None • Front'(S) 2.6 0.72 Double none none N N None Left' (W) 24.0 0:87 Double Std Drape Standard Bug Scr N N Metal . THERMAL MASS Type --------------------- Concrete,'Heavyweight Area Thick Covering (sf ) (in) Exposed ,287 3.50 Location/Description ----------------------------- Slab on Grade CERTIFICATE OF COMPLIANCE - Residential (part 2 of 2). CF -1R page 4 of 25 -------------------------------------- ----------------------------------•--- Project Name: Eisenberg Residence -Office Addition ;Date= 3/11/1996 ' Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665 ---=----------------------------------------------------------------------- • HVAC SYSTEMS Minimum Distrib Type Duct TStat System Type Efficiency and Location RVal Type Location/Comments ------------------------------------- ---- ------ ----------------------- SplitHtPump 6.800 HSPF'Ducts in Attic 4.2 SetBck Office Zone SplitHtPump10.500 SEER Ducts in Attic 4.2 SetBck Water No. " Tank Ext, WATER HEATING SYSTEMS Heater 'in Energy Size Insul System Name Distribution Type Type Sys Factor (gal) R -Val -------7------- -------------------------------- --- ------ ----- ----- Std Gas 50 gal or.Less Standard StorGas 1 0.53 • 50,0 12.0 AFUE WATER HEATER'EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot System Name System Type Eff Input Loss R -Val Light ----------------------- -------=--- ---- ----- ----- ----- ----- Std Gas 50 gal or Less DomesticHW 0.780 40000 .0.040 0.0 0 SPECIAL FEATURES/REMARKS COMPLIANCE STATEMENT This Certificate of Compliance lists the Building features and performance j& specifications needed to.comply-with Title 24, Parts 1 & 6 of the Califor- nia Code of'Regulations, and the administrative regulations to implement them. This certificate has been.signed by the individual with'overall design responsibility. When this.certificate-of compliance is submitted for a single Building plan to be built in multiple orientations, any shading feature that is.varied is indicated in the Special Features/Remarks section DESIGNER or OWNER DOCUMENTATION,AUTHOR -(Per Business & Professions Code) Tim Scott Robert A. Pitchford, Design & Drafting BREEZE AIR CONDITIONING 79-370 St Lucia t. 75-145 ST CHARLES PLACE. Dermuda n 01 PALM DESERT, CA 92260 ( 619 ) 6 Li # : ( 619 346-0855 (signature) ( date ) ig ENFORCEMENT AGENCY Name: Title Agency: Telephone: • `g-15--% ( date ) a (signature/stamp) (date) (7 MANDATORY MEASURES CHECKLIST (part 1 of 2) MF -1R page 5 of 25 -------------------------------------------.---------.--------------------. Project Name: Eisenberg Residence -Office Addition ;Date: 3/11/1996 Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665 ---------------------------------------------------------------------=----- • NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items,marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit• documents, the features noted shall be considered by.all parties as binding minimum'component performance . specifications for the mandatory measures whether they are shown elsewhere in the documents or -on this checklist only.. BUILDING ENVELOPE MEASURES Enforcement o Sec. 150(a): Minimum R-19 ceiling insulation. o Sec. 150(b): Loose fill insulation manufacturers labeled R -Value: o Sec. 150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior. mass walls).'*' o Sec. 150(d): Minimum. R-13 raised floor insulation in framed floors; Minimum R-8 in concrete raised floors.. o Sec. 150(1): Slab edge insulation - water absorption rate . no greater than 0.30, water vapor transmission rate no greater than 2.0 perm/inch. o Sec. 118: Insulation specified or installed meets California' Energy Commission quality standards. Indicate Type & form. o Sec. 116-117: Fenestration Products, Ext Doors & Infil/Exfil Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Manufactured fenestration products have label w/certified U -Value c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. o Sec. 150(8):. Vapor barriers mandatory in Climate Zones 14 ' and 16 only. o Sec. 150(f): Special infiltration barrier installed to comply with Sec. 151 -meets Commission quality standards. o Sec. 150(e): Installation of Fireplaces, -Decorative Gas Appliances and Gas Logs 1. Masonry and'factory-built fireplaces have: a. Closeable metal.or glass door b. Outside air intake,with damper and control c.. Flue damper and control 2,.No continuous burning gas pilots allowed. • MANDATORY MEASURES CHECKLIST,(part 1 of 2) MF -1R page 6 of 25 --------------------------------------------------------------------------- Project Name: Eisenberg'Residence-Office Addition ;Date: 3/11/1996. Docu•mentation:• BREEZE AIR CONDITIONING ;COMPLY 24 User 3665 SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES o Sec. 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. o Sec..150(i): Setback thermostat on all applicable heating systems. o Sec. 1. 2. 3. 4. 5. Enforcement 150(j)': Pipe and Tank Insulation Indirect hot water tanks.(eg unfired storage tanks -or backup solar hot water tanks) have insulation blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or , gr eater ) . First 5 feet of pipes closest to water heater tank, non -recirculation systems, insulated (R-4 or greater. All buried or exposed piping insulated in recirculation sections of hot water system. Cooling system piping below 55 F insulated. Piping insulated between heating source and indirect hot water tank. o Sec. 150(m) Ducts and Fans * 1. Ducts constructed, installed and sealed to comply with UMC Sections•1002 and 1004; ducts insulated to a minimum R-4.2 or ducts enclosed entirely within conditioned space. 2. Exhaust,systems have back8raft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible manually operated .dampers. o Sec,. 114:Pob1 and Spa Heating Systems and Equipment. 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" pipe between filter and heater for future solar heating., b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional .inl•ets and a circulation pump time switch. o Sec.'115: Gas-fired central furnace, pool heater,'spa heater or household cooking appliance have no,continuously burning pilot light. (Exception.: Non -electric&& cooking . appliance with pilot < 150 Btuh) LIGHTING MEASURES o Sec. 150(k): Lighting - 40 lumens/watt or greater for general lighting in kitchens and rooms with water -closets; • and,recessed ceiling fixtures IC (insulation cover) approved. POINT SYSTEM SUMMARY ------------------------------------------------------------------------=-- P -2R page 7 of 25 Project Name: Eisenberg Residence -Office Addition ;Date: 3/11/1996 Documentation: BREEZE AIR CONDITIONING - ;COMPLY 24 User 3665 -------------------------------------------------------------=-- • ---------- BUILDING DATA Conditioned Floor Area 287 sgft Number' of Stories 1 Occupancy Type Single.Fam Det SCORECARD Measure Points 1. Roof Insulation 0.0286 (U -Value). 0 2.. Wall Insulation 0.0592 (U -Value) -1 3. Raised Floor Insulation 0.0000 (U -Value) ^ 3a. Controlled Vent,Crawlspace. 0.0 (R -Value). ;-> -3 4. Slab Edge Insulation 0.9000 (f2 factor)_, 5. Infiltration Standard 0 6. Glass Heat Loss 0.84 10.5% 1 Sum 1-6 -3 7. Fenestration Heat Gain SC Orientation Area % Glass Open Eff % SER North 0.0 0.0 x 0.00 = 0.0 0.00 3 • East 3.5 1.2 x, 0.56 = 0'.7 0.81 3 South 2.6 0.9 x 0.88 = 0.8 1.00 1 West 24.0 8.4 x 0.77 6.4 0.86 -11 Skylight 0.0 0.0 x 0.00 0,0 0.00 0.- :8. 8.Interior. Thermal Mass 4.60 7 9: Exterior Wall Mass 0.00 p Sum 7-9 3 10. Heating System 0 . Zonal Control: No 11. Cooling System 2 12. Water Heating = 0 Point Total: 2 1C • 7 COMPUTER METHOD SUMMARY (part 1 of 3) C -2R page 8 of 25 ----------------------- --------------------------------------------------- Ptoject Name: Eisenberg Residence -Office Addition ;Date: 3/11/1996 Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665 -------------------------------------------------------- -------------- POINT SYSTEM COMPLIANCE SUMMARY Proposed Design Point Score. Budget Compliance Point Goal GENERAL INFORMATION , Compliance Method: Climate Zone: Conditioned Floor Area Building Type: Building Front Orientation: Number of Dwelling,Units:- Number of Stories: Floor Construction Type: Total Conditioned Volume: Conditioned Footprint Area: Ground Floor Area: 2 -Points *BUILDING COMPLIES* 0 Points COMPLY 24.version 5.00 15 287 sqf t Single Fam Det 180 deg. ( S ) 1 1 Slab on Grade. 2296 tuft 287 sqft 287 sgft BUILDING ZONE INFORMATION Floor #. of Vent Zone Name Area Volume Units Zone Type TStat-Type Hgt Area ----------------------- ------ ------ -------------------------- --- ----- Office Zone 287 2296 1:00 Conditioned Setback 2 ' n/a OPAQUE SURFACES Act Solar Type Area U -Val Azm Tilt Gains Form 3 Reference Location/Comments ZONE NAME = Office Zone Wall 124 0.059 0 90 'Yes R-21 Wall (W.21.2x6.16) Office Addition Wall 128 0.059 90 90 Yes R-21 Wall (W.21.2x6.16) Office Addition ,Door 17 0.387 90 '90 Yes Solid Wood Door Office Addition Wall 121 0 :059 180 90 Yes R-21 Wall ( W .21 .2x6 .16;) Off ice Addition Wall • 104 0.059 270 90 Yes R-21 Wall ( W .21 .2x6 .16) Office Addition Door 20 0.387 270 ,90 Yes Solid Wood Door Office Addition Roof 287 0.029 0 22 Yes R-38 Roof(R.38.2x14.16) Office .Addition COMPUTER METHOD SUMMARY (part 2 of 3) C -2R page 9 of 25 ------------------------- ----------------------------------------------------- Proje6t Name: Eisenberg Residence -Office Addition .;Date: 3/11/1996 Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665 ------------------------M -------- --------_______----_______-_________-__�__ • PERIMETER LOSSES F2 Insulation Type Length Factor R -Val Depth Location/Comments _-------- --------=---- ----- ----- ----------------------- ZONE NAME = Office Zone Exposed 68.0 0:90 0.0 0 in Office Addition FENESTRATION SURFACES SC Act Glass # Type Area Frame Div U -Val Azm Tilt Only, Location/Comments -------------------------- --- ----- --- ---- ----- --------------------- ZONE NAME = Office Zone . 1 Wdw Right'(E) .3.5 None No 0.72 90 -90 0.88 Office Addition 2 Wdw Front ( S ) 2..6 None No 0.72 180 90 0.88 Office Addition 3 Wdw Left ( W ) 24 .'0 Metal,No 0.87 270 90 0.88 Office Addition INTERIOR & EXTERIOR SHADING # Type Interior Shade Type SC Exterior Shade Type SC -- --------------------------- --------------------------- ---- I Wdw None 1.00 None 1.00 2 Wdw None 1.00 None 1.00' 3 Wdw Std Drape 0.78 Standard Bug Screen 0.87- .0 L� COMPUTER METHOD SUMMARY (part 3 of 3) C -2R page 10 of 25 ------------------------------ -------------------------------------------- Project Name: Eisenberg Residence -Office Addition ;Date: 3/11/1996 Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665 ----------------=------------------------=--------------------------------- OVERHANGS/SIDE FINS --Window-- # Type Ht Wd 1 Wdw 1.3 2.6 ----=Overhang------ Len Ht LExt RExt 2.0 0.1 2.0 2.0 ---Left Fin--- ---Right Fin -- Dist Len Ht" Dist Len Ht THERMAL MASS Area Thick Heat Inside Location Type (sf) (in) Cap' Cond Form 3 Reference R -Val . Comments ------------- ---- ----- ----- ----------------.----------- ------ ---=----- ZONE NAME =Office Zone Exposed Slab 287 3.50 28 0.98 n/a 0 HVAC SYSTEMS Minimum, Distrib Type Duct TStat System Type Efficiency and Location RVal Type Location/Comments SplitHtPump 6.800 HSPF.Ducts in Attic 4.2 SetBck Office Zone SplitHtPump10.500 SEER Ducts in Attic 4.2 SetBck Water No. Tank Ext. WATER HEATING SYSTEMS Heater in Energy Size Insul .System Name Distribution -Type Type Sys Factor (gal) R -Val • ------------------------- ---- -----= ----- ----- Std----Gas----50---gal----or--- Less= --- Standard StorGas 1 0.53 50.0 12.0 AFUE WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank 'Pilot System Name System Type Eff Input Loss R -Val Light Std Gas 50 gal or Less DomesticHW 0.780 40000 0.040 0.0 0 SPECIAL FEATURES/REMARKS • .• PROPOSED CONSTRUCTION ASSEMBLY -ENV-3 page 11 of 25 --------------------------------------------------------------------------- Project Name: Eisenberg Residence-Office•Addition ;Date: 3/11/1996 Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3.665 COMPONENT DESCRIPTION.' Assembly Name: R-21 Wall (W.21.2x6.16) ------------------------------- Assembly Type Wall Assembly Tilt: .90 deg (Vertical) . ; Framing Material: Wood Framing Spacing: O.C. Framing Percent: 15:0 Absorptivity: 0.70 --------------------------------- Sketch of Construction Assembly Roughness: Stucco, Wood Shingles - ASSEMBLY U -VALUE ADJUSTMENT FOR FRAMING (1 /22.53) x (0.85) + (1 / 6.98) x (0.15) Weight Heat Capacity:, 13.2 lb/sgft 3.23 _ 0.059 TOTAL U -VALUE _ TOTAL R -VALUE _ 0.059 16.89 .Th R -Value Construction Components ------------------------------------------=----------------------=--------- Fr (in) Cavity Frame Outside Air Film 0.17 0.17 1. Stucco 0.875 .0.17 0.17 2. Membrane, Vapor -Permeable Felt 0.010 0.06 0.06 3. Insulation, Mineral Fiber, R-21 *, 5.500 21.00 5.45 4.' Gypsum or Plaster Board 0.500 0.45 0.45, 5. 6. 7. 8. k '9. - Inside Air Fil.m ------------------------------------------------------ 0.68 . 0.68 Unadjusted 7 --------- R -Values ---------- 22.53 6.•98• ADJUSTMENT FOR FRAMING (1 /22.53) x (0.85) + (1 / 6.98) x (0.15) Weight Heat Capacity:, 13.2 lb/sgft 3.23 _ 0.059 TOTAL U -VALUE _ TOTAL R -VALUE _ 0.059 16.89 • • 0 PROPOSED CONSTRUCTION ASSEMBLY. ENV -3 page 12 of 25 -------------------------------------------------------------------------- Project Name: Eisenberg Residence -Office Addition ;Date: 3/11/1996 Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665 ------------------------ --------------------------------------------------- COMPONENT DESCRIPTION Assembly Name: R-38 Roof(R.38.2x14.16) Sketch of Construction Assembly ASSEMBLY U -VALUE Assembly.Type: Roof Assembly Tilt: 22 deg' (Tilted Up) Framing Material: Wo.od Framing Spacing: O.C. Framing.Percent: 10.0 % Absorptivity: 0.70 Roughness: Concrete, Asph. Shingles, .ADJUSTMENT Th R -Value Construction Components, ----------------------------------------------- Fr (in) Cavity Frame Air Film• 7 0.17 0.17 1. Tile Roofing 0.500 0.13 0.13 2. Membrane, Vapor -Permeable Felt 0.010 0.06 0.06 3. Plywood 0.500 0.62 0.62 4. Air Space * 1.750 0.77 1.73 5. Insulation, Mineral Fiber, R-38 * 11.500 38.00 11.39 6. Gypsum*or Plaster Board 0.500 0.45 0.45 7. 8. 9. , Inside Air Film ------- =----------------------------------------------------------- 0.61 0.61 Unadjusted R -Values --------- 40.81 5.16 15.16- .ADJUSTMENT FOR FRAMING ( 1 /40.81) x (0-90) + ( 1 /15.16) x (0.10) 0 .029 TOTAL U -VALUE = 0.029 TOTAL R -VALUE,= 34.91 Weight: 10.8 1'b/sqft Heat Capacity: 3.18 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 page'13 of 25 ----------------------------------------------- --------------------------- Project Name:. Eisenberg•Residence-Office Addition ;Date: 3/11/1996 .Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665 --------------------------------------------------------------------------- • COMPONENT DESCRIPTION Assembly Name Exposed Slab On Grade ------------------------------- Assembly Type: Floor - Assembly Tilt: 180 deg (Horizontal, Floor; Frami.ng.Material: None. Framing Spacing: O.C. Framing Percent: 0.0 % Absorptivity: 0.00 ------------------------------- Sketch of Construction Assembly Roughness: Concrete, Asph. Shingles ASSEMBLY U -VALUE Th' R -Value Construction Components 'Fr (in). Cavity Frame --------------------------------------------------------------------------- Outside Air Film 0.17 0.17 1. Earth 24.000 4.00 4.00 2. Concrete, 140 lb, Not Dried 3.500 0.28 0.28 3. • 4• 5. 6. 7. 8. 9. Inside Air.Film 0.92 0.92 ---------------------------------------------------------------------------- Unadjusted R -Values 5.37 5.37 ADJUSTMENT FOR FRAMING (1 / 5.37) x (1.00) + (1 / 5.37) x (0.00) - 0.186 TOTAL U -VALUE = 0.186 Weight: 210.8 lb/sqft Heat Capacity:. 42.17' • TOTAL R -VALUE = 5.37 L 0 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 page 14 of 25 --------------------------------.--------_-----------_----_-___-_-------------- Project Name:.Eisenberg Residence-Offic-e Addition ;Date: 3/11/1996 Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665 --------------------------------------------------_--------------------____-- COMPONENT DESCRIPTION ------------------------------- ------------------------------- Sketch of Construction Assembly ASSEMBLY U -VALUE. ' Assembly. Name: Solid Wood Door Assembly Type: Door Assembly Tilt: 90 deg (Vertical) Framing Material: None Framing Spacing: " O.C. Framing Percent: 0.0 % Absorptivity: 0.70 Roughness: Glass, Paint on Pine Th R -Value Construction Components_ Fr (in) Cavity Frame --------------------------------------------------------------------------- Outside Air Film 0.17 0.17 1. Softwood, Douglas Fir -Larch - 1.750 1.73 1.73 2. 3. 4. 5. 6. 7. .8. 9: Inside Air Film 0.68 0.68 --------------------------------------------------------------------_------- Unadjusted R -Values 2.58 2.58 ADJUSTMENT FOR FRAMING (1 / 2.58)- x. (1.00).+ (1 / 2.58) x (0.00) Weight: Heat Capacity: 5.1 lb/sgft l.;99 .0 .387 TOTAL U=VALUE = 0.387 TOTAL -R-VALUE = 2..58 HVAC SYSTEM HEATING & COOLING LOAD SUMMARY ---------------------- ---------------------------------------------------- page 15 of 25, Ptoject Name:-Eisenberg.Residence-Office Addition.. ;Date: 3/11/1996 Documentation: BREEZE AI.R CONDITIONING ;COMPLY 24 ,User 3665 -------------------------------------------------------------------7------- HVAC SYSTEM DESCRIPTION HVAC System Name: Office Zone Heating System Name: Lennox HP29-211/CB19-41 Cooling System Name: System'Multiplier: 1 Fan Schedule: All On Load Calcs Peak Load Method: COINCIDENT Relative Humidity: 50 % COOLING ZONES ON THIS SYSTEM PEAK HEATING -----------------------. PEAK SENSIBLE LATENT ----------- Office Addition (Jan 12am) 7501 ------------ ------ (Aug 2pm) 5994 X780 TOTAL ZONE LOAD 7501.. 5994 780 Duct Gains & Losses: 750 599 Ventilation: ( 0 CFM) 0 ( 0 CFM) 0 0 Return Air Lighting Gain 0, Supply/Return-Fan Gain: 0 0 TOTAL SYSTEM LOAD 8251 -6593 780 • SYSTEM OUTPUT AT DESIGN CONDITIONS MAIN HEATING & COOLING SYSTEM 12861 14241 0 TOTAL SYSTEM OUTPUT 12861 14241 0 NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment which will heat or cool this zone during the design conditions indicated. These numbers include no safety factor.; and. the HVAC contractor should. oversize by a reasonable margin to account for variations in weather conditions and the pick-up capacity required to bring the zone to temper- ature as a result of a setback thermostat. Those responsible for final equipment selection should note that Sensible and Latent Cooling Loads are indicated to allow for accurate comparison with manufacturer's output data. • RESIDENTIAL ZONE HEATING LOAD SUMMARY ------------------------------------------------------ ----------- page .16 of 25 =---------- P,roject'Name: Eisenberg Residence -Office Addition ;Date: 3/11/1996' Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User'3665 ------------------------------------- -------------------------------------- _Zone Name: _. Office Addition Design Indoor Dry Bulb Temperature: 72-F, Design Outdoor Winter Dry Bulb Temperature: 32 F . Desig.6 Temperature Difference: 40 F Conduction Area U -Value TD Btu/hr R-21 Wall (W.21.2x6.16) 477.2 x 0.0592 x 40.0 = 1130 Solid Wood Door 36.7 x 0.3872 -x 40.0 = 568 Glass Block Default (R) 3.5 x 0.7200 x 40.0 = 101 Glass Block Default ( R ) 2 .6 . x 0.7200 x-40.0 = 75 Double Clear Default(R) 24.0 x 0.8700 x 40.0 = 835 R-38 Roof(R .38 .2x14 .16 ) 287.0 -x 0.0286 x'40.0 = 329 Slab on Grade Perim = 68.0 x 42 = 2822 Infiltration: 1_00 x 0.018'x 287 sf, x ' 8.0 ft x 1.00 AC x 40.0. = 1641 TOTAL HOURLY HEAT LOSS FOR ZONE 7501 .Heating AirFlow: 7501 Btu/hr / [1.07 x 33 F DeltaT )] = 212 cfm • E • • k RESIDENTIAL ZONE COOLING LOAD'SUMMARY ----rr------------r-------------------------- ; -------------------- page 17 of 25 Project Name: Eisenberg Residence-Office'Addition ;Date: --------- 3/11/1996 k Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665 Zone Name: Office Addition Design Indoor Dry Bulb Temperature: 76 F Design'Outdoor Summer Dry Bulb Temperature: 112 F Design Temperature Difference: 36 F Conduction Area U -Value DETD Btu/hr R-21 Wall (.W.21.2x6.16) 477.2 x 0.0592 x 29.6 - 836 Solid Wood Door '1 36.7 x 0.3872 x 29.6 = 421 Glass Block Default ( R ) 3.5 x 0..7200 x 36.0 - 91 Glass Block Default (R) 2.6 x .0.7200 x 36.0 = 67 Double Clear Default(R) 24.0 x 0.8700 x 36.0 - 752 R-38 Roof(R.38.2x14.16) 287.0 x. 0.0286 x 50.0 = 411 Infiltration: 1.00 x 0.018 x '287 sf x 8.0 ft x 1.00 AC x 36.0 = 1477 Shaded Unshaded Solar Gain Orient. Area SGF Area SGF SC Glass Block Default ( R ) East [ ' 3 .5 x 15 + 0.0 x.731 x 0.88 = 46 Glass Block Default (R) South [. 0.0 x 15 + 2.6 x 32] x 0.88 = 73' Double Clear Default(R ) West [ 0.0 x 15 + 24.0 x 731 x 0.66 = 1154 Internal Gain. Op Frac. ----------------------------- AreaHeat Gain Conv. Lighting 1.00 x --------------- 287.0 x 0.200, x ----- 3.413 = 196 Equipment 1.00 x 287.0 x 0.100 x 3.413 _ 98 Occupants 1.00 x 287.0 x 255 / 333 = 220 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ZONE 5994 Latent Gain Op 'Frac. ----------------------- Area Heat ------- Gain Conv. Btu/hr -------- Equipment 1.00 x --------- 287.0 x 0.000 x ----- 3.413 ------ = 0 ..Occupants 1.00 x 287.0 x 255 / 333 = 220 Infiltration: 1.00 x 0.018 x 287 sf. x 8.0 ft. x 1.00 AC x 12.5 = 514 TOTAL HOURLY LATENT HEAT -GAIN FOR ZONE 780 Cooling AirFlow: 5994 Btu/hr / 11.07, x`21 F DeltaT)] = 266 cfm k LE NOX . IES COILS — BLOWER COILUNITS CB19 AND CBH19 SE/9112101/ UP -FLOW, DOWN -FLOW AND HORIZONTAL BLOWER COIL UNITS CBH19 *12,600 to 65,500 Btuh (3.7 to 19.2 M) Cooling Capacity Bulletin #210056 11,500 to 60,000 Btuh (3.4 to 17.6 M Heat Pump Heating Capacity January 1995 6,400 to 102,400 Btuh 11.9 to 30.0 kW) Optional Electric Heat Supersedes 'ARI Standard 210/240 Ratings With Matching Outdoor Unit April 1994 Applications—The CB19 and CBH19 blower coil units are de- signed for multi -position installation in a basement, utility room, alcove, closet, crawlspace or attic. Units are applicable to expansion valve systems in cooling applications and check and expansion valve systems in heat pump applica- tions. Units have factory installed check and expansion valve. Several models are available in varying sizes with a wide range of cooling and heating capacities. See Condensing Unit bulletins in section Cooling Units — Condensing Units for cooling capacities. See Heat Pump Outdoor Unit Bulletins in section Heat Pumps — Matched Remote Systems for cooling and heating capacities. Optional field installed electric heaters are available in several sizes for additive heating capacity. CB19 models are applicable to up -flow or down -flow dis- charge air applications. Units are shipped for up -flow ap- plications and may easily be field converted to the down - flow position by turning the unit upside down and repositioning the coil, drip shields and cabinet access panel. Filters are notfurnished and must be provided bythe install- er. An optional side return air adapter with filter(s) is avail- able for up -flow applications only. An optional additive base is available for models with electric heat installed in the down -flow position on combustible floors. CBH19 models are designed for horizontal discharge air ap- plications. Units are furnished with left hand air discharge as standard and may befield changedto right hand discharge by turning the unit over (end for end) and repositioning the coil. CBH19-51 and CBH19-65 models are furnished in a two piece cabinet with blower and optional electric heaters in one sec- tion and the indoor coil in the other. Hardware is furnished for field connection of cabinets. Filters are not furnished and must be provided by the installer. CB19 MODEL— UP-FLO CB19 MODEL — DOWN-FLO Typical Applications CBH19 MODEL— HORIZONTAL Up -Flow Installation with optional electronic air cleaner Horizontal Installation Down -Flow Installation 0 The maple leaf symbol in this bulletin denotes Canadian only usage where applicable ©1995 Lennox Industries Inc. NOTE — Due to Lennox' ongoing commirtment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. 1,• (4 SPECIRCATIONS -_CB19 UP-FLOW/DOWN-FLOW Model Number C819-21 C819-26 CB19-31 CB19-41 CB19-51 CB19.65 Net face area - ft.z (mz) 4.22 (0.39) 4.22 (0.39) 5.27 (0.49) 5.27 (0.49) 7.0 (0.65) 7.0 (0.65) Tube outside diameter - in. (mm) 3/8(9.5) 3/8(9.5) 3/8(9.5) 3/8(9.5) 3/819.5► 3/8(9.5) Evaporator Number of rows 3 3 3 3 3 3 Coil Fins per inch (fins per m) 12 (472) 12 (472) 13 (512) 13 (512) 14 (551) 14 (551) Suct. (vapor) line conn. - in. (mm) sweat 5/806) 5/8(16) 3/4(19) 3/4(19) 7/8(22.2) 1-1/8(28) Liquid line conn. - in. (mm) sweat 3/8(9.5) 3/8(9.5) 3/8(9.5) 3/8(9.5) 3/8(9.5) 3/8(9.5) Condensate drain connection (pvc) - in. (mm) (2)3/4(19) (2) 3/4 (19) (2)3/4(19) (2)3/4(19) (2)3/4(19) (2)3/4(19) Nominal cooling capacity -tons (kW) 1-1/2(5.3) 2(7.0) 2-1/2(8.8) 3(10.6) 4(14.1) 5(17.6) Refrigerant HCFC -22 Blower wheel nominal diameter x width - in. (mm) 9 x 7 (229 x 178) 9 x 8 (229 x 203) 10 x 7 (254 x 178) 10 x 9 (254 x 229) 11 x 8 (279 x 203) 12 x 9 (317 x 229) Blower motor output - hp (W) 1/10(75) 1/5(149) 1/3049) '11/3 (249) 1/3 (249) 1/2(373) ttNumber and size of filters in. (1)16x20x1 (1)20x20x1 (1)20x25x1 m m (1) 406 x 508 x 25 (1) 508 x 508 x 25 (1) 508 x 635 x 25 Electrical characteristics 208/230 volts - 60 hz - 1 ph 208/230/460 volt 60 hz - 1 ph Shipping weight - lbs. (kg) 1 package 143 (65) 146 (66) 167 (76) 167 (76) 209 (95) 213 (97) • Optional Accessories (Must Be Ordered Extra) Catalog number 95G73 951374 95G75 Side Return Air Filter Adaptor (Up -Flow Only) Number and size of filters in. (1) 16 x 20 x 1 (1) 20 x 20 x 1 (2) 16 x 25 x 1 mm (1) 406 x 508 x 25 (1) 508 x 508 x 25 (2) 406 x 635 x 25 Shipoing weight - lbs. (kg) 4 (2) 5 (2) 24 (11) Down -Flow Catalog number 85G52 85G53 85G54 Combustible Base Ship. wt. - lbs. (kg) 8 (4) 8 (4) 8 (4) ECB19-2.5 *Output - Stuh (kW) 9,000 (2.6) 9,500 (2.8) - - - - - - - - - - - - tA.F.U.E. 100% 100% - - - - - - - - ECB19-5 *Output - Btuh (kW) 18,000 (5.3) 18,000 (5.3) 18,000 (5.3) 18,000 (5.3) 19,000 (5.6) tA.F.U.E. 100% 100% 100% 100% 100% - - - - ECB 19-6 *Output - Btuh (kW) 21,000 (6.2) 22,000 (6.4) 22,000 (6.4) 22,000 (6.4) 23,000 (6.7) - - - - tA.F.U.E. 100% 100% 100% 100% 100% - - - - ECB19-75 *Output - Btuh (kW) 25,000 (7.3) 25,000 (7.3) 25,000 (7.3) 25,000 (7.3) 26,000 (7.6) - - - - tA.F.U.E. 100% 100% 100% 100% 100% ---- ECB19-8 *Output - Btuh (M28,000 (8.2) 28,000 (8.2) 29,000 (8.5) 29,000 (8.5) 29,000 (8.5) 30,000 (8.8) tA.F.U.E. 100% 100% 100% 100% 100% 100% Electric Heat ECB19-10 *Output - Btuh (kW) 35,000 (10.3) 35,000 (10.3) 35,000 (10.3) 35,000 (10.3) 36,000 (10.5) 37,000 (10.8) tA.F.U.E. 11 100% 100% 100% 100% 100% 100% Capacity ECB19-12.5 *Output - Btuh (kW) - - - - 44,000 (12.9) 44,000 (12.9) 44,000 (12.9) 45,000 (13.2) 46,000 (13.5) tA.F.U.E. - - - - 100% 100% 100% 100% 100% EC819-15 *Output- Btuh (kW) 52,000 (15.2) 52,000 (15.2) 53,000 (15.5) 53,000 (15.5) 54,000 (15.8) tA.F.U.E. - - - - 100% 100% 100% 100% 100% ECE19-20 *Output - Btuh (kW) - - - - - - - - 70,000 (20.5) 70,000 (20.5) 71,000 (20.8) tA.F.U.E. - - - - - - - - - - - - 100% 10040 100% EC619-25 *Output - Stuh (kW) - - - - - - - - - - - - - - - - 87,000 (25.5) 88,000 (25.8) tA.F.U.E. ---- ---- ---- ---- 10040 100% EC819-30 *Output - Btuh (kW) - - - - - - - - - - - - - - - - 105,000 (30.8) tA.F.U.E. ---- ---- ---- 100% luo, , UO, V L. 140iIull C111ummy uaseu un v.a. uuc test proceaures ana accoraing to r i c iaoeung regulations ttFilters are not furnished and must be ordered extra. *Includes additional blower motor heat capacity. -3- �.:fl1MENS/ONS—inches (mm) UP-FLOWPOSITION • 1.1 1-1/16 (27171 E 12712-7) D SUPPLY AIR OPENING or TOP VIEW 1 CB19-31 & -41 inch I mm / A L4-1/41108) —J 1219 ELECTRICAL INLETS 31761 CDRAI NS(2) g (Both Sides( C —►{II G� DRAINS 121 • 1.1/2 Return Air 1.1/2 138) 1381 '�11 F 1-1/16 3/4 (27) Return Air (19) AIR FLOW SIDE VIEW 591 OPTIONAL 23-1/4 591 5/6 I ELECTRIC HEAT 641 ❑ 1161 Innnuunun - (Fieldlnstalled) 457 20 508 Iunnunllnn 15-7/8 403 19-1/8 486 20-7/8 530 F I Ih 545 O/ — 545 23-7/16 595 G II 381 18-1/4 'BLOWER it 20 ( BLOWER 1 H 9-1/8 I A / 11-5/8 295 J 7-7/16 189 10-5/16 262 11-11/16 H K LIQUID 133 5-1/4 133 10 254 LINE TT 2.1/21641 FILTERRAILS , ' / 10-1/16 SUCTION 1 N 5-5/8 2) IFiher Not 5-3/16 K LINE = P RETURN AIR Furnished) ` . J 18-1/4 I I 1 OPENING (Either Side 14-1/4 1 362 18-1/4 464 251/4 641 Bottom, Model No. _ - M 1 CB19-31 & -41 inch I mm / A L4-1/41108) —J 1219 51 31761 CDRAI NS(2) I B 18-1/4 G� DRAINS 121 • 1.1/2 Return Air 1.1/2 138) 1381 '�11 F 1-1/16 3/4 (27) Return Air (19) FRONT VIEW SIDE VIEW Model No. CB19-21 & -26 inch ymm 1 CB19-31 & -41 inch I mm CB19-51 & -65 inch mm A 48 1219 51 1295 60 1524 B 18-1/4 464 21-1/2 546 23-1/4 591 C 23-1/4 591 23-1/4 591 25-1/4 641 D 18 457 18 457 20 508 E 15-7/8 403 19-1/8 486 20-7/8 530 F 21-7/16 545 21-7/16 545 23-7/16 595 G 15 381 18-1/4 464 20 508 H 9-1/8 232 10-3/4 273 11-5/8 295 J 7-7/16 189 10-5/16 262 11-11/16 297 K 5-1/4 133 5-1/4 133 10 254 L 7-9/16 192 9-3/16 233 10-1/16 256 M 5-5/8 143 5-3/16 132 7-11/16 195 N 18-1/4 464 18-1/4 464 20-1/4 514 P 14-1/4 1 362 18-1/4 464 251/4 641 CB19 DOWN -FLOW POSITION 1-1/2 (38) 3/4 1.1/16 NOTE — When unit with optional electric heat is installed on a combustible floor, (19) 4F127) an additive base is required. Base is optional and must be ordered extra. G When using additive base make opening in floor 2-3/8 inches (60mm) RETURN larger (side to side) and 2-1/2 inches (64mm) larger (front to rear) than • AIR unit supply air opening. OPENING Model No. C819-21 & -26 inch mm CB19-31 & -41 inch mm CB19-51 & -65 inch mm A 48 1219 51 1295 60 1524 B 118-1/4 464 21-1/2 546 23-1/4 591 C 23-1/4 591 23-1/4 591 25-1/4 641 D 18 457 18 457 20 508 E 15-7/8 403 19-1/8 486 20-7/8 530 F 21-7/16 545 21-7/16 545 23-7/16 595 G 15 381 18-1/4 464 20 508 H 9-1/8 232 10-3/4 273 11-5/8 295 J 8-15/16 227 12-3/4 324 11-7/18 302 K 5-1/4 133 5-1/4 133 10 254 L 7-9/16 192 9-3/16 233 b0-1/16 256 M 9-3/16 233 22 559 25-7/8 657 1-1/2(381 TOP VIEW FILTER RAILS 121 (Filter Not Furnished) Imo— C —•I Imo---- B _70— l LIQUIDI H r LINE M / AIR FLOW SUCTION J UNE L \ 1 (76) CONDENSATE I DRAINS (2) A I BLOWER 1 I I BLOWER( I oELECTRICAL I I i -- r — INLETS J— — —I— �IIIIIIIIIIIIIIII (Both Sides) nnlnlnlul if ❑ 1.7/16 s/s It61 OPTIONAL 1-1/16 D 1.1/16 E 127) ELECTRIC HEAT (271 (271 Supply Air (Field Installed) Supply Air SIDE VIEW FRONT VIEW _70— l 0 LIsC'Cu�� dog o� d` rIPO �w cua�.c' 10.00 to 11.00 SEER *17,100 to 57,000 Btuh (5.0 to 16.7 kW) Cooling Capacity *17,000 to 55,000 Btuh (4.9 to 16.1 kW) Heating Capacity Typical Application Iill�l I� *ARI and DOE Certified Ratings CERTIflGTION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS USTED WITH ARI ISO 8000 REGISTERm WORLD CLASS DUALITY tsuiietln No. ziuu/3 April 1995 Supersedes November 1994 Applications Unit Cabinet • SEE R's up to 11.00. • Heavy gauge steel cabinet with five station metal wash • Heating C.O.P.'s up to 3.31. process. • HSPF's up to 7.50 (Region IV). • Baked -on outdoor enamel paint finish provides rust and • 1-1/2 through 5 Ton (5.3 through 17.6 kW) sizes. corrosion protection. • Single or three phase power supply. • Painted base section. • Vertical air discharge allows concealment behind shrubs at • Control box is conveniently located with all controls grade level or out of sight on a roof. factory wired. • Matching up -flow, down -flow and horizontal blower coil • Corner patch plate allows access to compressor. units with supplemental electric heat provide a wide range • Drainage holes are provided in base section for moisture of cooling and heating capacities and applications. See ARI removal. Ratings table for match -ups. • Also applicable to indoor add-on coils matched with conventional furnaces with FM21 Heat Pump Control. See Compressor bulletin indexed in this tab section. • Designed for dependable efficiency with minimum • For complete data on indoor blower coil units and FM21 operating cost. coils, see tab section Coils – Blower Coil Units. • Suction cooled and overload protected with internal • Units shipped completely factory assembled, piped and pressure relief. wired. Each unit is test operated at the factory insuring • Hermetically sealed with built-in protection from excessive proper operation. current and temperatures. • Installer must set outdoor unit, connect refrigerant lines • Crankcase heater assures proper compressor lubrication. and make electrical connections to complete job. • Running gear assembly resiliently suspended internally Approvals inside case. Compressor installed in unit on resilient rubber • Rated in accordance with ARI Standard 210/240-89. mounts assuring low sound and vibration free operation. • Sound rated in Lennox reverberant sound test room in accordance with ARI Standard 270-84. Defrost Control • Tested in the Lennox Research Laboratory environmental *Solid-state time/temperature defrost control is furnished as test room. • Rated according to U.S. Department of Energy (DOE) test standard equipment. •Control initiates a defrost cycle every 30, 60 or 90 minutes procedures. • Outdoor units and components within bonded for of compressor "on" time at outdoor temperatures below grounding to meet safety standards for servicing required 35` F (2°C) (factory setting 60 minutes). by U.L., N.E.C. and C.E.C. by defrost cycle 14 minutes. • Units are U.L. listed and C.S.A. certified. • Defrost thermostat mounted on liquid line determines • Developed in accordance with ISO 9000 quality standard. when defrost cycle is required and when to terminate cycle. Equipment Warranty • Compressor — Ten years (residential applications), five Reversing Valve years (non-residential applications). • Factory installed 4 -way reversing valve provides rapid • All other covered components — five years (residential), change in refrigerant flow direction resulting in quick one year (non-residential applications). changeover from cooling to heating and vice -versa. • Refer to Lennox Equipment Limited Warranty certificate • Valve operates on pressure differential between outdoor included with unit for specific details. unit and indoor unit. 4 The maple leaf symbol in this bulletin denotes Canadian only usage where applicable "1995 Lennox Industries Inc. '• NOTE — Due to Lennox' ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability.— -ELECTRICAL .DATA Model No. HP29-211 HP29-261 HP29-311 HP29-411 HP29-413 Line voltage data - 60 hz 208/230v 1ph 208/230v 1ph 208/230v 1ph 208/230v 1ph 208/230v 3ph 460v 3ph Compressor Rated load amps 8.6 9.8 13.7 16.2 10.3 4.3 Power factor .97 .96 .92 .90 .83 .83 Locked rotor amps 49.0 56.0 75.0 96.0 75.0 40.0 Outdoor Coil Fan Motor Full load amps 1.1 1.1 1.1 1.1 1.1 0.55 Locked rotor amps 1.9 1.9 1.9 1.9 1.9 1.0 Rec. maximum fuse or circuit breaker size (amps) 20 20 30 35 20 10 *Minimum circuit ampacity r Reier to n, ntinnel ,., r�..�ac.,., ci,.....:__i r_�_ 11.9 13.5 18.4 21.4 14.0 6.5 •- - v u 'Lei none wire, wse and disconnect size requirements. NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. - TWICAL,DATA - Model No. HP29-461 HP29-463 HP29-511 HP29-513 HP29-651 HP29-653 Lin(: voltage data - 60 hz 208/230v 1ph 208/230v 3ph 460v 3ph 208/230v 1ph 208/230v 3ph 460v 3ph 575v 3ph 208/230v 1ph 208/230v 3ph 460v 3ph 575v 3ph Compressor Rated load amps 17.5 12.8 6.4 23.4 14.0 7.1 5.8 26.9 17.3 9.0 7.1 Power factor .98 .93 .93 .98 .88 .88 .88 .98 .86 .86 .86 Locked rotor amps 92.0 87.0 44.0 110.0 91.0 46.0 37.0 123.0 128.0 64.0 51.0 Outdoor Coil Fan Motor Full load amps 1.1 1.1 0.55 1.9 1.9 0.90 0.90 1.9 1.9 0.90 0.90 Locked rotor amps 1.9 1.9 1.0 4.1 4.1 2.1 2.1 4.1 4.1 2.1 2.1 Rec. maximum fuse or circuit breaker size (amps) 40 25 15 50 30 15 10 60 40 20 15 *Minimum circuit ampacity *RetertoNation I C d; EI 23.0 17.1 8.6 31.2 19.4 9.8 8.2 35.5 1 23.5 12.2 9.8 a or ana Ian ectncal Code manual to determine wire, fuse and disconnect size requirements. NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. • IGERAWUNE.KITS- Outdoor unit Model No. Length of Line Set Lines Model No. ft. m Liquid Line Outside Dia. Vapor Line Outside Dia. in. mm in. mm HP29-211 HP29-261 L15-21-20 20 6 , 5/16 7.9 5/8 15.9 L15-21-25 25 8 L15-21-35 35 11 05-217--TO-775 HP29-31140 L15-31-20 20 6 5/16 7.9 3/4 19 L15 31-30 30 9 L15-31-40 12 L15 31-50 50 15 HP29-410 L15-41-20 20 6 3/8 9.5 3/4 19 L15-41-30 30 9 1-15-41-40 40 12 L15-41-50 50 15 HP29-460 HP29-510 L15-65-30 30' 9 3/8 9.5 7/8 22.2 L15-65-40 40 12 L15 65-50 50 15 HP29-650 *Not available 3/8 9.5 1-1/8 28.5 Field fabricate. INSTALLATION CLEARANCES-- inches (mm) NOTE - 48 inch (1219 mm) clearance required on top of unit. *NOTE - One side must be 36 inches (914 mm) for service. Two of the remaining three sides may be 12 inches (305 mm). -4- DIMENSIONS = inches (mm) 4 INLET AIR 4 INLET AIR INLET4 AIR TOP VIEW 24-1/4 (616) SIDE VIEW 011)7` X1111) (111) OPTIONAL UNIT L L INLET STAND-OFF KIT (4) COMPRESSOR (Field Installed) AIR COIL DRAIN OUTLETS _jj \ — (Around perimeter of base) /1 6-3/8 VAPOR LINE (162) CONNECTION o LIQUID LINE _E 6-3/8 d-3/8 CONNECTION (162)—*0i(111)1-4 TOP VIEW BASE SECTION 24-1/4 (616) 111110 OUTDOOR DISCHARGE* AIR T� COIL FAN \ 3/4 (19) B A I . � COMPRESSOR VAPOR & LIQUID LINE CONNECTION ELECTRICAL INLETS 2-3/4 (70) 11 OPTIONAL UNIT / STAND-OFF KIT (4) (Feld Installed) SIDE VIEW Model No. A B HP29 211,} in. 25 24-1/4 HP29-261 mm 635 616 in. 29 28-1/4 HP29-311 mm 737 718 HP29-411-413 in. 33 32-1/4 HP29-461-463 HP29-511-513 HP29-651-653 mm 838 819 —7— 4-3/8 (111) 4.3/8 1111) INSTALLATION CERTIFICATE CF -6R. page,25 of 25 --------------------------------------------------------------------------- Project Name: Eisenberg Residence -Office Addition ;Date: 3/i1/1996 Documentation: BREEZE AIR CONDITIONING ;COMPLY 24 User 3665 ----------------- ---------------------------------------------------- • I, the undersigned, verify that the equipment listed in the category above my signature is the actual equipment installed and,that the equipment meets or exceeds the requirements.of the Appliance Efficiency Standards. In addition-, I have verified that the equipment is equivalent to or more efficient than the equipment -specified on the Certificate.of Compliance submitted to demonstrate compliance with the Energy Efficiency Standards for Residential Buildings'. HVAC SYSTEMS Heat. Equip CEC Certified Manuf. Actual Distrib Type Duct Heat Heat System Type -Make &.Model Number Eff. and Location RVal Load Output •---------------------------------- ------------------- ----------- ------ SplitHtPump Lennox HP29-211/CB19-41 6.800 Ducts in Attic 4.2 8251 12861 Cool. Equip CEC Certified Manuf. Actual Distrib Type Duct System Type Make & Model Number Efficiency and Location RVal -----------------------------------------=---------------------- ---- SplitHtPump 10.500 -SEER Ducts in Attic 4.2 • Signature Date Name Water No. Tank Ext. WATER HEATING SYSTEMS Heater in Energy Size Insul CEC Cert. Make & Model Distribution Type Type Sys Factor (gal) R-Val ------------------------------------------------- ----------------------- --- ------ ----- -__-- Std Gas 50 gal or Less Standard StorGas 1 0.53 50.0 12.0 AFUE WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot System Name System Type Eff Input Loss R -Val Light ----------------------- ----------- ---- ----- ----- ----- ----- Std Gas 50 gal or Less DomesticHW 0.780 40000 .0.040 0.0 0 C� J FAUCETS & SHOWER -HEADS: All faucets and showerheads are listed in the. Commissions, Directory Of Certified Faucets And Showerheads, pursuant to Title 24, Part 6, Subchapter 2', Section 111. Signature Date. Name L, T4hf P.O. BOX 1504 Building 78-105 CALLE ESTADO Address 56-665 Kerion LA QUINTA, CALIFORNIA 92253 Owner Su>nr i Se UmpaoY Mailing BUILDING: TYPE CONST. Address 42-600 Gook Street Suitt' 200 A.P. Number PGA West City Zip Tel. p'SIM Rnedk%% Q9*An UM -0000 Legal Description Phase 'H Contractor I Mational land & Mortgage Address City lZip State Lic. I City & Classif. 2WI30 Lic. # 328 Arch., Engr., Designer Address Tel. CityI Zip I State I Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 70 OO) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) ❑ I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and stale laws relating to building construction, and hereby authorize representatives of this city to enter the above- mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip No. OCC. GRP,: OT548 Project Description_ Corwww Ailsa Mock irAll Sq. Ft. No. No. Dw. Size Stories Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal 252.40 Const. Mech. Electrical Plumbing S.M.I. 1.75 Grading Driveway Enc. Infrastructure TOTAL 1 $253.75 REMARKS IWt ;A 4' tf4 i itt' rrt.}�, _ Tri aU ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date 16 RWmit Validated by: Validation: CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES IST FL. SO. FT. ® $ 2ND FL. SO. FT. POR. SQ. FT. ® GAR. SQ. FT. ® CAR P. I SQ. FT. WALL SO. FT. ® SQ FT ® ESTIMATED CONSTRUCTION VALUATION $ UNITS MOBILEHOME SVC. POWER OUTLET YARD SPKLR SYSTEM BAR SINK ROOF DRAINS DRAINAGE PIPING DRINKING FOUNTAIN. URINAL WATER PIPING NOTE: Not to be used as property tax valuation BONDING FLOOR DRAIN MECHANICAL FEES FORMS WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER GAS (ROUGH) GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED OTHER APPIEQUIP. LAUNDRY TRAY AIR HANDLING UNIT CFM TEMP. POLE KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER. B.T.U. SQ. FT. ® c BATH TUB SQ. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SQ. FT. RESID ® 1+/4 c SEWAGE DISPOSAL SQ.FT.GAR ® 3/<c HOUSE SEWER REMARKS: GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBING UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER OR SEPTIC TANK ROUGH WIRING. DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPIEQUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu. yd. $ plus x$ =$ LUMBER GR. FINAL INSP. FRAMING FINAL INSP. ROOFING REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING MESH INSULATION/SOUND FINISH GRADING AL INSPECTIO `l`/' CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURESIINITIALS GARDEN WALL FINAL Building Address 56-665 Herian Owner Sunrise Cowan • " P.O. BOX 1504 78-105 CALLE ESTADO LA QUINTA, CALIFORNIA 92253 Mailing Address42,.608 soak Street Suite 248 City Zip Tel. Pala Desert 92250 1 568-2828 Contractor �T^ City anal H►rtoaae & Land State Lic- City a Classitit88334 I Lic. # 398 Arch., Engr., Designer Address CityI Zip I State Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 70pp) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, after, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or krprove for the purpose of sale.) ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No .Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California- Date-owner alifornia.Dateowner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY In affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lenders Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I car ily that 1 have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above- mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip LlZ_ No. 07229 e . —141 11LDING: TYPE CONST. OCC: GRP.; P. Number M Description Tract 24803 t Description Phase 4H +- Plan H2B REMARKS }tr 16W = ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date 228%90 Permit Validated by: Validation: Sq. Ft. 2545 Size No. Stories No. Dw. Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation $193,449 PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. tJ Const. 96I.Su Mech. 115.11JU Electrical ZJ. 1!J Plumbing 152- 0 S. M.I. 13. 44 Grading Driveway Enc. Infrastructure -ss •s •� re fit' ult 21M.80 ntra We z, n .ixiui TOTAL REMARKS }tr 16W = ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date 228%90 Permit Validated by: Validation: CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES 1ST FL. SO. FT. ® $ UNITS SLAB GRADE ROUGH PLUMB. BONDING YARD SPKLR SYSTEM 2ND FL. SO. FT. FORMS —EiI ERdEPTIC ROUGH WIRING MOBILEHOME SVC. BAR SINK POR. SO. FT. ® AS (ROUGH• (u(/j>, ��++ �bV METER LOOP GAR. SO. FT. ® POWER OUTLET ROOF DRAINS GAS (FINAL) TEMP. POLE DRAINAGE PIPING CAR P. SO. FT. ® GROUT WATER HEATER WALL SO. FT. FINAL INSP. DRINKING FOUNTAIN SO FT ® WATER SYSTEM URINAL ESTIMATED CONSTRUCTION VALUATION $ =$ WATER PIPING NOTE: Not to be used as property tax valuation ONAL INS FLOOR DRAIN MECHANICAL FEES WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTOXDISH) APPLIANCE DRYER GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED VENTILATION LAUNDRY TRAY AIR HANDLING UNIT CFM FIRE ZONE ROOFING KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEMIPERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SO. FT. ® c BATH TUB '�ATHING 6 SO. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID ® 11/4 c SEWAGE DISPOSAL SO.FT.GAR ® V4c HOUSE SEWER GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACKG. (((G��i VVVV GROUND PLUM .f UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS —EiI ERdEPTIC ROUGH WIRING DUCT WORK ROCKSTORAGE FOUND. REINF. AS (ROUGH• (u(/j>, ��++ �bV METER LOOP HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu. yd. $ plus x$ =$ LUMBER GR. ONAL INS RAMING ,6 `1?--��\ FINAL INSP. OFING - �✓ - V VV N Sc / 1 ,G; T �-{ 1 -p2v (- REMARKS VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL '�ATHING 6 MESH NSULATION/SOUN FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURESIINITIALS GARDEN WALL FINAL