14-0246 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 14-00000246 Property Address: 56665 MERION APN: 762-023-024- - - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 15028 Applicant: Architect or Engineer: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: M&M JEFF HILLERBRAND 56-665 MERION LA-QUINTA CA LA QUINTA, CA 92253 Contractor: LANG CONSTRUCTION 80590 CAMINO SAN GREGERIO BERMUDA DUNES, CA 92203 (760)702-7744 Lic. No.: B I4'fC*s VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 4/07/14 ---- -`*�-------------------------------------------------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION .,� I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in ff 11 force and effect., LicenseClass: 748605 LLLicense No.: B 74 B COf OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter, 9 (commencing with Section 7000) of Division 3 of the Business and Professions Codel or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 _) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: . CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 1889409-2013 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if 1 should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, l shall forthwith comply with those provisions. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT , IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to.any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county-ordlna cn es and state -laws -relating to building construction, and hereby authorize representatives of thiscounty `to enter upon the'above-mentioned property for inspection purposes. F �p Date: 4 i�� Signature (Applicant or Agent): O 41W. 441Alf - Application Number . . . . . 14-00000246 Permit . . ROOM ADDITION 2013 Additional desc . Permit Fee 181.61 Plan Check Fee .00 Issue Date Valuation 0 Expiration Date 9/22/14 Qty Unit Charge Per Extension 1.00 120.1200 LS MISC ROOM ADDN, 1ST 100 SF 120.12 1.00 ---------------------------------------------------------------------------- 61.4900 EA MISC ROOM ADDN, ADDL 500 SF 61.49 Permit . . . ELECTRICAL 2013 Additional desc . . Permit Fee . . . . 23.83 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 9/22/14 Qty Unit Charge Per Extension 1.00 23.8300 LS ELEC FIXTURES, FIRST 20 23.83 .00 ---------------------------------------------------------------------------- 143.0000 LS ELEC NEW RES, FIRST 1 KSF .00 Permit . . . MECHANICAL 2013 Additional desc . . Permit Fee 11.92 Plan Check Fee .00 Issue Date Valuation . . . . 0 Expiration Date 9/22/14 Qty Unit Charge Per Extension 1.00 ---------------------------------------------------------------------------- -11.9200 EA MECH APPL REP/ALT 11.92 Permit . . . PLUMBING 2013 Additional desc . Permit Fee . . . . 00 Plan Check Fee .00 Issue Date . . . 3/26/14 Valuation . . . . 0 Expiration Date . . 9/22/14 ---------------------------------------------------------------------------- Special Notes and Comments NEW 186 SQ. FT. OFFICE ADDITION March 26, 2014 1:39:05 PM jjohnson. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 2.00 HOURLY PLAN CHECK 122.50 PLAN.CHECK, ELECTRICAL 23.83 PLAN CHECK, ROOM ADDITION 185.90 PLAN CHECK, MECHANICAL 4.77 LQPERMIT Application Number . . . . . 14-00000246 --------------------------------------------------------------------7------- Other Fees . . . . . . . . . STRONG MOTION (SMI) - RES 1.50 Fee summary Charged ---------- Paid --------------------- Credited ---------- Due ----------------- Permit Fee Total 217.36 .00 .00 217.36 Plan Check Total .00 .00 .00 .00 Other Fee Total 340.50 .00. .00 340.50 Grand Total 557.86 .00 .00 557.86 LQPERMIT Bin # City of La Quinta Building 8t Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: j • s2 F�1 ellli Owner's Name:/�"l ��� vD A. P. Number: 76 Z Z 7 004 Address: 5th ` 6 6 � � ► i�Q i(� ,`D Legal Description: IT -A 4-2 TtZ 2+ O o Contractor: ��-'•�7.rTelephone: City, ST, Zip: tf2L'( "T4 —79077 ! 2:•:::.>>:;:�:k:.<;::::,.:;�:<:::>�;::::.:::::.>::.:<:>:;::<::::::>.:<:r:.::s:;«:. Address: Project Description: City, ST, Zip: TeleP hone• State Lic. : Lemic. -T T& Ork >Q G �C.ityy ,#::. Designer:�;q 'r(cG�l Address: City., ST, Zip: Q('[ t—17Z. Telephone: '% / {�, 6 b ZS� <>'`>r>`>` ::::.::...:.:::,.::.;:::::::::; ..;;.::•: :......:: Consdv i o . Occupancy: State Lic. #{: Project type circle one): New Add'n Alter Repair Demo Name of Contact Person:t Sq. Ft.: # Stories: 1 #Units: ,p Telephone # of Contact Person: 7� Z U Estimated Value of Projecto,90, (vo APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections �XO Plan Check Deposit Truss Calcs. Called Contact Person 3 Z 0 Plan Check Balance. Title 24 Calcs. Plans picked up p 2 Construction Flood plain plan Plans resubmitted( Mechanical Grading plan 2°" Review, ready for correctio /issue Fy Subcontactor List Called Contact Person 26 Plumbing 0660 "a . Grant Deed Plans picked up H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees •IAAFAAM COPY Total Permit Fees �,�- •CP• 14��'�`-1� �-�c. � �� MAR 0s zona Date 4/7/14 No. 32048 Owner Hillerbrand Address 56665 Merion City La Quinta Zip 92253 Tract # Type Residential Addition Lot # No. Street Unit 1 56665 Merion Unit 2 Unit 3 Unit 4 Unit 5 Comments CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 S.F. Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 APN # Jurisdiction Permit # No. of Units Lot # No. Q 13ERMUDADUNES M RANCHO MIRAGE d INDIAN WELLS 'v PALM DESERT ,y LA QUINTA �QINDIO y� 762-023-024 La Quinta Street S.F. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This.certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt/Larry Lang Check No. Bank Name/Recipient of Certificate Telephone 760/702-7744 Funding Exempt By Dr. Gary Rutherford Superintendent Fee collected /exem t d by Patri is Barbuzza Payment Recd $0.00 j t Over/Udder Signature NOTICE: Pursuant to Government Code Section 6 (d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run Morn the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting T:: � r• BUILDING ENERGY ANALYSIS REPORT PROJECT: Mr. & Mrs. Jeff Hillebrand 56-665 Mericon La Quinta, CA 92253 Project Designer: Robert A. Pitchford Design and Drafting 77-622 Country Club Dr. Suite O Palm Desert, Ca 92211 (760) 346-2856 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 nF,-A OF LA QUI TA NG & SAFETY DEPT. Job Number: PROVE CONSTPTION 3 (�f Date: I -$� - 3/13/2014 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. ,,. I EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201403-13T17:01:01 /D: • Ah • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Mr. & Mrs. Jeff Hillebrand Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 3/13/2014 Project Address 56-665 Mericon La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,949 Addition 186 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ® No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes IZI No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity f Features see Part 2 of 5 Status Roof Wood Framed Attic R-19 2,747 Existing Wall Wood Framed R-11 3,292 Existing Door Opaque Door None 18 Existing Slab Unheated Slab -on -Grade None 2,949 Perim = 320' Existing Roof Wood Framed Attic R-19 186 New Wall Wood Framed R-13 461 New FENESTRATION U- Orientation Area(ft) Factor Exterior SHGC Overhang Sidefins Shades Status Skylight 16.0 0.550 0.67 none none None Existing Front (E) 160.1 0.710 0.73 none none Bug Screen Existing Left (S) 305.0 0.710 0.73 none none Bug Screen Existing Rear (M 314.2 0.710 0.73 none none Bug Screen Existing Right (N) 32.5 0.710 0.73 none none Bug Screen Existing Right (N) 2.0 0.800 0.39 none none Bug Screen Existing Rear (W) 20.0 0.790 0.59 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 78% AFUE Split Air Conditioner 10.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 existing Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing GITY OF LA QUIN i A WATER HEATING BUILDING & SAFETY DEPT. Qty. Type Gallons Min. Eff Distrib tion .r r.�ir +p Nl;=JStiatus cr;u i-Y)IM9TRI IrTION EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-13 71 7:01:01 ID: Page 3 of 19 r • • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Mr. & Mrs. Jeff Hillebrand Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 3/13/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. CITY OF I AQUINT r t.9?II' z SAFETY DEPT. j FVH1 CONSTRUCT T EnemyPro 5.1 by EnemySoft User Number: 6712 Run Code: 201403-13T17:01` 1 `--/0 a e 4 of 19 • • PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Mr. & Mrs. Jeff Hillebrand 1 ❑ Multi Family m Existing+ Addition/Alteration 3/13/2014 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kgtu/ft2- r Space Heating 14.89 14.20 0.69 Space Cooling 245.95 244.57 1.38 Fans 45.03 44.72 0.31 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 305.87 303.50 2.37 Percent Better Than Standard: 0.8% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 80 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 868 160 Fuel Available at Site: Natural Gas (S) 1,324 305 Raised Floor Area: 0 (M 1,017 334 Slab on Grade Area: 2949 (N) 1,396 35 Average Ceiling Height: 12.9 Roof 2,949 16 Fenestration Average U -Factor: 0.71 TOTAL: 850 Average SHGC: 0.73 Fenestration/CFA Ratio: 28.8 REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and comple Documentation Author Company Scott Design and Title 24, Inc, 3/13/2014 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelopeeating require installer testing and certification and field verification by an approved HE a e.r. �4 � F Designer or Owner (per Business & Professions Code) r i Company Robert A. Pitchford Design and Drafting G�ji�.I.r r" + D Address 77-622 Country Club Dr. Suite O Name Robert Pitchford City/State/Zip Palm Desert, Ca 92211 Phone (760) 346-2856 FSS g� dliV.� f L�c nese#� ate DATER �EnenqyPrz) 5.1 6 EnerSoft User Number: 6712 Run Code: 201403 -13T17:01:0; ---1D 0 • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Mr. & Mrs. Jeff Hillebrand Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1311312014 OPAQUE SURFACE DETAILS Surface T e Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 2,747 0.049 R-19 0 20 Existing 4.2.1-A4 Existing Residence Wall 638 0.110 R-11 80 90 Existing 4.3.1-A2 Existing Residence Door 18 0.500 None 80 90 Existing 4.5.1-A4 Existing Residence Wall 811 0.110,R-11 170 90 Existing 4.3.1-A2 Existing Residence Wall 280 0.110 R-11 170 90 Removec 4.3.1-A2 Existing Residence Wall 482 0.110 R-11 260 90 Existing 4.3.1-A2 Existing Residence Wall 180 0.110 R-11 260 90 Removec 4.3.1-A2 Existing Residence Wall 1,362 0.110 R-11 350 90 Existing 4.3.1-A2 Existing Residence Slab 2,7631 0.730 None 0 180 Existing 4.4.7-A1 Existing Residence Roof 1861 0.049 R-19 0 20 New 4.2.1-A4 Office Addition Wall 52 0.102 R-13 80 90 New 4.3.1-A3 Office Addition Wall 208 0.102 R-13 170 90 New 4.3.1-A3 Office Addition Wall 201 0.102 R-13 260 90 New 4.3.1-A3 Office Addition Slab 186 0.730 None 0 180 Existing 4.4.7-A1 Office Addition FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Skylight 16.0 0.550 Default 0.67 1 Default 0 Existing Double Non Metal Clear Existing Residence 2 Window 80.0 0.710 Default 0.73 1 Default 80 Existing Double Metal Clear Existing Residence 3 Window 9.8 0.710 Default 0.73 Default 80 Existin Double Metal Clear Existing Residence 4 Window 24.5 0.710 Default 0.73 Default 80 Existing Double Metal Clear Existing Residence 5 Window 1 9.8 0.710 Default 0.73 Default 80 Existing Double Metal Clear Existing Residence 6 Window 18.0 0.710 Default 0.73 Default 80 Existing Double Metal Clear Existing Residence 7 Window 18.0 0.710 Default 0.73 Default 80 Existing Double Metal Clear Existing Residence 8 Window 32.0 0.710 Default 0.73 Default 170 Existing Double Metal Clear Existing Residence 9 Window 8.0 0.710 Default 0.73 Default 170 Existing Double Metal Clear Existing Residence 10 Window 8.0 0.710 Default 0.73 Default 170 Existing Double Metal Clear Existing Residence 11 Window 32.0 0.710 Default 0.73 Default 170 Existing Double Metal Clear Existing Residence 12 Window 80.0 0.710 Default 0.73 Default 170 Existing Double Metal Clear Existing Residence 13 Window 25.0 0.710 Default 0.73 Default 170 Existing Double Metal Clear Existing Residence 14 Window 24.0 0.710 Default 0.73 Default 170 Existing Double Metal Clear Existing Residence 15 Window 48.0 0.710 Default 0.73 Default 170 Existing Double Metal Clear Existing Residence 16 Window 48.01 0.710 Default 0.73 Default 170 Existing Double Metal Clear Existing Residence (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-8 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Len H t LExt RExt Dist Len Ri ht Fin Hat Dist Len H t 1 None 1.00 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 1 U 14 Bug Screen 0.76 c , ,1. �� it 2, C, IN C CD 15 Bug Screen 0.76 i 16 IBug Screen 0.76�- I3THUCTION EnergyPro 5.1 by EnergrySoft User Number: 6712 RunCode: 2014-03-13T17:01:01 ID: Page 6 bf 19 Lim 1 G_ CST I I :7 • `CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Mr. &Mrs. Jeff Hillebrand Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 3/13/2014 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 80.0 0.710 Default 0.73 Default 260 Existing Double Metal Clear Existing Residence 18 Window 25.0 0.710 Default 0.73 Default 260 Existing Double Metal Clear Existing Residence 19 Window 24.0 0.710 Default 0.73 Default 260 Existing Double Metal Clear Existing Residence 20 Window 10.0 0.710 Default 0.73 Default 260 Existing Double Metal Clear Existing Residence 21 Window 127.2 0.710 Default 0.73 Default 260 Existing Double Metal Clear Existing Residence 22 Window 48.01 0.710 Default 0.73 Default Double Metal Clear Existing Residence 260rExisting 23 Window 25.0 0.710 Default 0.73 Default 350Double Metal Clear Existing Residence 24 Window 7.5 0.710 Default 0.73 Default 350Double Metal Clear Existing Residence 25 Window 2.0 0.800 NFRC 0.39 NFRC 350Glass Block Existing Residence 26 Window 20.0 0.790 Default 0.59 Default 260Dual Metal Tint Office Addition (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC Hat Wd Ove hanq Left Fin Ri ht Fin Len Hat LExt I RExt Dist I Len Hat Dist Len Hat 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 I , i bialLtJR%3 & ISN F UH W046TRUCTION EnergyPro 5.1 by EnerqySoft User Number: 6712 Run Code: 2014-03-13T17:01:04 ID: Pa -gel 7 of 19 • • • 'CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Mr. & Mrs. Jeff Hillebrand Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1311312014 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built HVAC 1 existing Existing Residence 2,763 35,919 1989 Office Addition 186 2,232 Totalsi 1861 2,7631 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 existing 2 Central Furnace 78% AFUE Split Air Conditioner 10.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC 1 existing Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing WATER HEATING SYSTEMS Sstem Name Qty- T e Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status CEC Standard MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 _ o Q — - - - S tfem?Name,g— Pipe ,Len , Pipe Insul. Thick. Qtv. THP Plenum Outside Buried ❑ a • 1 f �1.fF L- . ❑ (�•" t V ❑ P 'e i, i Va.i"46 1 - RUCT ()NI EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 201403-13T17:01 t01 E ID: Pale 8 of 19 4 r MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name r. & Mrs. Jeff Hillebrand Date 3/13/2014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (") below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all 'oints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent Ll -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent Ll -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent Ll -factor. 150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(4)3A: Insulation is protected from damage, includingthat due to sunlight, moisture d ui =- it ime�tx m'ainY' natio, a d Wind §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is e c ose"d'ent �e yd hl conditioned space. __:�UtLuo\j-, - SAF Ep 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating acid Cer1if cation Co`Y o_ n. FOR CONSTRUCTION EnergyPro 5.1 by EnergySofi User Number: 6712 Run Code: 201403-13T17:04 1p /D: Pa4e 9 of 19 4 F_' MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date r. & Mrs. Jeff Hillebrand 3/13/2014 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction return lines or built -u connections for future solar heatin . 14 b 2: Outdoor ools ors as that have a heat um or as heater shall have a cover. rand 14(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or o rammed to run onl durin off eak electric demand eriods. 50 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of 150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. §150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Wafts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Liqhting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 wafts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. ..uit_DING & SAFETY DEPT. PAS PROVED EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 201403-13T17:01:01 ,. lD y - Pa 10 of 19 )ATE BY I 4 r 4 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date r. & Mrs. Jeff Hillebrand 1311 014 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §l50(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130 131 134 and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. `TY OF LaAk QUI N TA BuILDINC & SAFE7Y DEPT. PPHCiVMD FOR CONSTRUCTION QATF rav EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201403-13717:0.1:01 1- Page 11 of 19 4 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date r. & Mrs. Jeff Hillebrand 3/13/2014 System Name Floor Area HVAC 1 existing 2,949 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 Total Room Loads COIL CFM 4,238 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 71,000 89,003 5,065 2,106 72,965 Total Output Btuh 142,000 Return Vented Lighting Return Air Ducts Return Fan Ventilation F Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 0 0 Output Btuh/s ft 48.2 7,547 5,184 Cooling System o 0 Output perSystem 60,000 0 0 0 0 Total Output Btuh 120,000 0 7,547 I 104,097 5,065 0 Total Output Tons 10.0 5,184 Total Output Btuh/s ft 40.7 Total Output s ft/Ton 294.9 83,333 Air System CFM perSystem 1,900 HVAC EQUIPMENT SELECTION Airflow cfm 3,800 Existing 94,893 0 142,000 Airflow cfm/s ft 1.29 Airflow cfm/Ton 380.0 Outside Air % 0-0% Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 94,893 0 142,000 Aug 3 PM FJan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 °F 71 OF 71 OF 106 OF 0 Outside Air 0 cfm Supply Fan Heating Coil 105 OF 3,800 cfm ROOM 71 OF 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF 72 / 58 OF 72 / 58 OF 48 / 47 OF 10 Outside Air C-- 0 cfm 0 Supply Fan Cooling Coil 3,800 cfm CITY®� /48 F L.! U I N BUILD1N(44:,S ° �A E aR°pi Tk 72 / 58 OF A tl"" 5"'" D 7017/,57F 1 11 Tt OAT1= EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 201403-13T17:01:0.1___ ID age, 12 of 19 C • 'ROOM LOAD SUMMARY Project Name Mr. & Mrs. Jeff Hillebrand Date 3/13/2014 System Name HVAC 1 existing Floor Area 2,949 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM I Sensible Latent CFM Sensible Existing Residence Existing Residence 1 4,056 85,170 4,796 4,056 85,170 4,796 1,966 68,103 Office Addition Office Addition 1 183 3,833 269 183 3,833 269 140 4,862 JINTA ; UiL ING & SIAEM ' Total includes ventilation load for zonal systems. PAGE TOTAL TOTAL' J''k 0 G :'`d w � a 0-%%.9 r— u �2�38',,�89,�0,0 �, -� ,106 2,965 4,238 89'003 . ,0 5 , 06 2,965 EnemyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2014-03-13T17:01:01� `-1i3 -- --- —Page 1J of 19 own • • 'ROOM HEATING PEAK LOADS Project Name Mr. & Mrs. Jeff Hillebrand Date 3/13/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Residence Floor Area 2,763.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT 'F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = Btu/hr Default Roof 1978 to Present 2,747.0 0.0490 46 6,192 Double Non Metal Clear 16.0 0.5500 46 405 Default Wall 1978 to 1991 3,292.1 0.1100 46 16,658 Double Metal Clear 811.8 0.7100 46 26,513 Wood Door 18.1 0.5000 46 416 Glass Block 2.0 0.8000 46 74 Slab -On -Grade perim = 290.0 0.7300 46 9,738 Items shown with an asterisk (') denote conduction Infiltration: 1.00 X 1.064 �� Schedule Air Sensible Fraction through an interior surface X 2,763 X Area another roo. r� �" 13.00 La t0�.2iz7l,/ Height A 9ti FOR Pa a TOtal 59,996 A"`"�� � ii �� agar 60d CXz r--�–,�, `Ik I A– 'AT' vE f1k�tC> n,e ..� I ���! 46 ,–_ 8,107 TOTAL HOURLY HEAT LOSS FOR ROOM f " " ' ` E) ' t 63,103 i DATE EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 201403-13717:01:0.1_ ID- — �� a 14 of 19 'ROOM HEATING PEAK LOADS •Project Name Mr. & Mrs. Jeff Hillebrand Date 3/13/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Office Addition Floor Area 186.0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF • Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F = = = = = = = = = = = = = = = = = = = = = = = = = = = = Btu/hr R-19 Roof(R.19.2x12.16) 186.0 0.0490 46 419 R-13 Wall (W. 13.2x4.16) 461.0 0.1020 46 2,163 Dual Metal Tint 20.0 0.7900 46 727 Slab -On -Grade perim = 30.0 0.7300 46 1,007 Items shown with an asterisk (') denote conduction Infiltration: 1.00 X 1.064 �� Schedule Air Sensible Fraction through an interior surface X 186 X Area another reo �X� 12.00 X:: 1,0.30 Height v. AC i FOR 4,316 A P /- �:a6� . _ At P ROVEILD T 546 • TOTAL HOURLY HEAT LOSS FOR ROOM 862 DATE BY Energ Pro 5.1 by EnergySoft User Number. 6712 RunCode: 201403-13T17:01:01-- I^ Paae of 19 I , 4 • r� r}RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Mr. & Mrs. Jeff Hillebrand 3/13/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Residence Outdoor Dry Bulb Temperature 112 OF Floor Area 2, 763.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Ranqe: 34 OF Opaque Surfaces Default Roof 1978 to Present Default Wall 1978 to 1991 Wood Door Default Wall 1978 to 1991 Default Wall 1978 to 1991 Default Wall 1978 to 1991 Orientation (E) (S) Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' c = = c = = = = = 2,747.0 0.0490 56.0 637.8 0.1100 32.1 18.1 0.5000 32.1 811.0 0.1100 27.1 481.8 0.1100 32.6 1,361.5 0.1100 29.0 0.0 41.3 9.8 80.2 0.0 41.3 18.0 80.2 0.0 41.3 18.0 Page Total Fanacfrafinn Skylight Window existing2 Window Existing3 Window Existing4 Window Existing5 Window Existing6 Window Existing6 Window Existing8 Window Existing9 Internal Gain (Arianfafinn (N) (E) (E) (E) (E) (E) (E) (S) (S) Shaded Unshaded Btu/hr 7, 538 2,253 291 2,419 1, 725 1 18,5681 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = _ = _ _ c _ 0 _ 0.0 36.7 16.0 127.4 0.0 41.3 80.0 80.2 0.0 41.3 9.8 80.2 0.0 41.3 24.5 80.2 0.0 41.3 9.8 80.2 0.0 41.3 18.0 80.2 0.0 41.3 18.0 80.2 0.0 41.3 32.0 45.2 0.0 41.3 8.0 45.2 Page Total 4.0 Occupants X 230 Btuh/occ. - 1.0 Dwelling Unit X 1,600 Btu = Infiltration: 1.064 X 0.94 X 171.09 X 42 Air Sensible CFM ELA AT 2,038 6,417 786 1.965 786 1,444 1,444 1,445 361 16,6871 tstuinr 920 1,600 1 7.1511 [TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM R5 nn Latent Gain Occupants 4•o Occupants X°1U "tu.;i^Ilw o,L AQU Infiltration: x,771 X o.s4 X n1.os X 0.00523 - BUILDING & SAFETY Air Sensible CFM ELA AW Af.,Y4 ROVEI FOUR CON TPI It _Tar Btu/hr • 3, 4+ 1 I 0 • • 'RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Mr. & Mrs. Jeff Hillebrand 3/13/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Residence Outdoor Dry Bulb Temperature 112 OF Floor Area 2,763.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranae: 34 OF Surfaces Orientation Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = GLF c = _ _ c _ c c 0.0 41.3 8.0 45.2 0.0 41.3 32.0 45.2 0.0 41.3 80.0 45.2 0.0 41.3 25.0 45.2 0.01 41.3 24.0 45.2 0.0 41.3 48.0 45.2 0.0 41.3 48.0 Page Total Fenestratinn Window Existingl0 Window Existing 11 Window ex12 Window ex13 Window ex 14 Window ex15 Window ex16 Window ex17 Window ex18 Orientatinn Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF c = _ _ c _ c c 0.0 41.3 8.0 45.2 0.0 41.3 32.0 45.2 0.0 41.3 80.0 45.2 0.0 41.3 25.0 45.2 0.01 41.3 24.0 45.2 0.0 41.3 48.0 45.2 0.0 41.3 48.0 45.2 0.0 41.3 80.0 83.0 0.0 41.3 25.0 83.0 Page Total Btu/hr 0 Btu/hr 361 1,445 3,612 1,129 1,084 2,167 2,167 6,642 2,076 20,684 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. - 920 Equipment 1.0 Dwelling Unit X 1,600 Btu - 1,600 Infiltration: 1.064 X 0.94 X 171.09 X 42 = 7,151 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 85.170 Latent Gain Btu/hr Occupants 4.0 Occupants X ,^ 13oc'� 1 �f 800 �•d Infiltration: 4,771 X 0.94 X 171.09 X 0.00523="�UILDING & SA EYDE 3,996 Air Sensible CFM ELA AW f� P t VE D TOTAL HOURLY LATENT HEAT GAIN FOR ROOM N ' I Toa • f � U 'RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Mr. & Mrs. Jeff Hillebrand 3/13/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Existing Residence Outdoor Dry Bulb Temperature 112 OF Floor Area 2,763.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total o Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window ex19 (W) 0.01 X 41.3 + 24.0 X 83.0 = 1,993 Window ex20 2109 0.0 X 41.3 + 10.0 X 83.0 = 830 Window ex21 (W) 0.0 X 41.3 + 127.2 X 83.0 = 10,561 Window ex22 0.0 X 41.3 + 48.0 X 83.0 = 3,985 WindowExisting23 (N) 0.0 X 41.3 + 25.0 X 64.8 = 1,619 Window Existing4 (N) 0.0 X 41.3 + 7.5 X 64.8 = 486 Window Existing25 (N) 0.0 X 30.5 + 2.0 X 43.0 = 86 X + X - X 1 +1 X - Page Total 19,560 Internal Gain Btu/hr- tu/hrOccu Occupants ants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.94 X 171.09 X 42 = 7,151 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 85,170 Latent Gain Occupants 4.0 Occupants X �2 �� "" ` tuhhoCC. -� 00 I DI�lC & SAF ETY DEPT Infiltration: 4,771 X 0.94 X 171.09 X 0.00523 =' AP1aPw0�E 3, 96 Air Sensible CFM ELA ow I FOR CONSTRUCTION TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4.7961 'J BY EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 201403-13717:01:01 19 4 6 3 C C L—A RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Mr. & Mrs. Jeff Hillebrand 3/13/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Office Addition Outdoor Dry Bulb Temperature 112 OF Floor Area 186.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-19 Roof(R.19.2x12.16) (N) 186.0 X 0.0490 X 56.0 = 510 R-13 Wall (W. 13.2x4.16) (E) 52.0 X 0.1020 X 32.1 = 170 R-13 Wall (W. 13.2x4.16) (S) 208.0 X 0.1020 X 27.1 = 575 R-13 Wall (W. 13.2x4.16) (W) 201.0 X 0.1020 X 32.6 = 667 X X = X X = X X = X X = X X = Page Total 1,923 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr tArindow.26 (W) 0.0 X 37.7 + 20.0 X 71.4 = 1,429 X + X - X + X - X + X - X + X - X + X - X + X - X + X - X + X - Page Total 1,429 Internal Gain Btu/hr— tu/hrOccu Occupants ants 0.0 Occupants X 23o Btuh/occ. 0 Equipment 0.0 Dwelling Unit X 1,600 _ Btu - 0 Infiltration: 1.064 X 0.94 X 11.52 X 42 = 481 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM CffYO F LA UUIN I Latent Gain Occupants 0.0 Occupants X 2 MOW= 9i`�� &Spy 0 s'4 tib{ 0 Infiltration: 4,771 X 0.94 X 11.52 X 0.00523 = �SA-N ��c o kcONSTR 69 Air Sensible CFM ELA AW BY TOTAL HOURLY LATENT HEAT GAIN FOR ROOM BATE EnergyPro 5.1 by EnerqvSoft User Number: 6712 Run Code: 201403-13717:01:01 ID: Pae 19 of 19