14-0246 (AR)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: 14-00000246
Property Address: 56665 MERION
APN: 762-023-024- - -
Application description: ADDITION - RESIDENTIAL
Property Zoning: LOW DENSITY RESIDENTIAL
Application valuation: 15028
Applicant: Architect or Engineer:
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Owner:
M&M JEFF HILLERBRAND
56-665 MERION
LA-QUINTA CA
LA QUINTA, CA 92253
Contractor:
LANG CONSTRUCTION
80590 CAMINO SAN GREGERIO
BERMUDA DUNES, CA 92203
(760)702-7744
Lic. No.: B I4'fC*s
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 4/07/14
---- -`*�--------------------------------------------------------------------------------------------
LICENSED CONTRACTOR'S DECLARATION
.,� I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in ff 11 force and effect.,
LicenseClass: 748605 LLLicense No.: B 74 B COf
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter, 9 (commencing with Section 7000) of Division 3 of the Business and Professions Codel or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
1 _) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
. CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERMIT
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 1889409-2013
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if 1 should become subject to the workers' compensation provisions of Section
3700 of the Labor Code, l shall forthwith comply with those provisions.
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT ,
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to.any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county-ordlna cn es and state -laws -relating to building construction, and hereby authorize representatives
of thiscounty `to enter upon the'above-mentioned property for inspection purposes.
F �p
Date: 4 i�� Signature (Applicant or Agent): O 41W. 441Alf
-
Application Number . . . . . 14-00000246
Permit
. . ROOM ADDITION 2013
Additional
desc .
Permit Fee
181.61 Plan Check Fee
.00
Issue Date
Valuation
0
Expiration
Date 9/22/14
Qty Unit Charge Per
Extension
1.00
120.1200 LS MISC ROOM ADDN, 1ST 100 SF
120.12
1.00
----------------------------------------------------------------------------
61.4900 EA MISC ROOM ADDN, ADDL 500 SF
61.49
Permit
. . . ELECTRICAL 2013
Additional
desc . .
Permit Fee
. . . . 23.83 Plan Check Fee
.00
Issue Date
. . . . Valuation . . . .
0
Expiration
Date 9/22/14
Qty Unit Charge Per
Extension
1.00
23.8300 LS ELEC FIXTURES, FIRST 20
23.83
.00
----------------------------------------------------------------------------
143.0000 LS ELEC NEW RES, FIRST 1 KSF
.00
Permit
. . . MECHANICAL 2013
Additional
desc . .
Permit Fee
11.92 Plan Check Fee
.00
Issue Date
Valuation . . . .
0
Expiration
Date 9/22/14
Qty Unit Charge Per
Extension
1.00
----------------------------------------------------------------------------
-11.9200 EA MECH APPL REP/ALT
11.92
Permit
. . . PLUMBING 2013
Additional
desc .
Permit Fee
. . . . 00 Plan Check Fee
.00
Issue Date
. . . 3/26/14 Valuation . . . .
0
Expiration
Date . . 9/22/14
----------------------------------------------------------------------------
Special Notes and Comments
NEW 186 SQ.
FT. OFFICE ADDITION
March 26, 2014
1:39:05 PM jjohnson.
----------------------------------------------------------------------------
Other Fees
. . . . . . . . . BLDG STDS ADMIN (SB1473)
2.00
HOURLY PLAN CHECK
122.50
PLAN.CHECK, ELECTRICAL
23.83
PLAN CHECK, ROOM ADDITION
185.90
PLAN CHECK, MECHANICAL
4.77
LQPERMIT
Application Number . . . . . 14-00000246
--------------------------------------------------------------------7-------
Other Fees . . .
. . . . . .
STRONG MOTION
(SMI) - RES
1.50
Fee summary
Charged
----------
Paid
---------------------
Credited
----------
Due
-----------------
Permit Fee Total
217.36
.00
.00
217.36
Plan Check Total
.00
.00
.00
.00
Other Fee Total
340.50
.00.
.00
340.50
Grand Total
557.86
.00
.00
557.86
LQPERMIT
Bin #
City of La Quinta
Building 8t Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
Project Address: j • s2 F�1 ellli
Owner's Name:/�"l ��� vD
A. P. Number: 76 Z Z 7 004
Address: 5th ` 6 6 � � ► i�Q i(�
,`D
Legal Description: IT -A 4-2 TtZ 2+ O o
Contractor: ��-'•�7.rTelephone:
City, ST, Zip: tf2L'( "T4
—79077 ! 2:•:::.>>:;:�:k:.<;::::,.:;�:<:::>�;::::.:::::.>::.:<:>:;::<::::::>.:<:r:.::s:;«:.
Address:
Project Description:
City, ST, Zip:
TeleP hone•
State Lic. :
Lemic.
-T T& Ork >Q G
�C.ityy ,#::.
Designer:�;q
'r(cG�l
Address:
City., ST, Zip: Q('[ t—17Z.
Telephone: '% / {�,
6 b ZS�
<>'`>r>`>` ::::.::...:.:::,.::.;:::::::::;
..;;.::•:
:......::
Consdv i o . Occupancy:
State Lic. #{:
Project type circle one): New Add'n Alter Repair Demo
Name of Contact Person:t
Sq. Ft.:
# Stories: 1
#Units:
,p
Telephone # of Contact Person: 7� Z U
Estimated Value of Projecto,90, (vo
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Rec'd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item Amount
Structural Calcs.
Reviewed, ready for corrections
�XO
Plan Check Deposit
Truss Calcs.
Called Contact Person
3 Z 0
Plan Check Balance.
Title 24 Calcs.
Plans picked up p
2
Construction
Flood plain plan
Plans resubmitted(
Mechanical
Grading plan
2°" Review, ready for correctio /issue
Fy
Subcontactor List
Called Contact Person
26
Plumbing 0660 "a .
Grant Deed
Plans picked up
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'"' Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
•IAAFAAM
COPY
Total Permit Fees
�,�- •CP• 14��'�`-1� �-�c. � �� MAR 0s zona
Date
4/7/14
No.
32048
Owner
Hillerbrand
Address
56665 Merion
City
La Quinta Zip 92253
Tract #
Type
Residential Addition
Lot # No. Street
Unit 1 56665 Merion
Unit 2
Unit 3
Unit 4
Unit 5
Comments
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road
La Quinta, CA 92253
(760) 771-8515
S.F.
Unit 6
Unit 7
Unit 8
Unit 9
Unit 10
APN #
Jurisdiction
Permit #
No. of Units
Lot # No.
Q 13ERMUDADUNES
M RANCHO MIRAGE d
INDIAN WELLS 'v
PALM DESERT ,y
LA QUINTA
�QINDIO y�
762-023-024
La Quinta
Street S.F.
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This.certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Exempt/Larry Lang Check No.
Bank Name/Recipient of Certificate Telephone 760/702-7744
Funding Exempt
By Dr. Gary Rutherford
Superintendent
Fee collected /exem t d by Patri is Barbuzza Payment Recd $0.00 j
t Over/Udder
Signature
NOTICE: Pursuant to Government Code Section 6 (d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees
or other payment identified above will begin to run Morn the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
T:: � r•
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Mr. & Mrs. Jeff Hillebrand
56-665 Mericon
La Quinta, CA 92253
Project Designer:
Robert A. Pitchford Design and Drafting
77-622 Country Club Dr. Suite O
Palm Desert, Ca 92211
(760) 346-2856
Report Prepared by:
Tim Scott
Scott Design and Title 24, Inc,
77-085 Michigan Drive
Palm Desert, Ca 92211
(760) 200-4780
nF,-A
OF LA QUI TA
NG & SAFETY DEPT.
Job Number: PROVE
CONSTPTION
3 (�f
Date: I -$� -
3/13/2014
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
,,. I EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201403-13T17:01:01 /D:
•
Ah
•
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Mr. & Mrs. Jeff Hillebrand
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
3/13/2014
Project Address
56-665 Mericon La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,949
Addition
186
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ® No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes IZI No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity f Features see Part 2 of 5 Status
Roof Wood Framed Attic
R-19 2,747 Existing
Wall Wood Framed
R-11 3,292 Existing
Door Opaque Door
None 18 Existing
Slab Unheated Slab -on -Grade
None 2,949 Perim = 320' Existing
Roof Wood Framed Attic
R-19 186 New
Wall Wood Framed
R-13 461 New
FENESTRATION U-
Orientation Area(ft) Factor
Exterior
SHGC Overhang Sidefins Shades Status
Skylight 16.0 0.550
0.67 none none None Existing
Front (E) 160.1 0.710
0.73 none none Bug Screen Existing
Left (S) 305.0 0.710
0.73 none none Bug Screen Existing
Rear (M 314.2 0.710
0.73 none none Bug Screen Existing
Right (N) 32.5 0.710
0.73 none none Bug Screen Existing
Right (N) 2.0 0.800
0.39 none none Bug Screen Existing
Rear (W) 20.0 0.790
0.59 none none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
2 Central Furnace 78% AFUE
Split Air Conditioner 10.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC 1 existing Ducted
Ducted Attic, Ceiling Ins, vented 4.2
Existing
GITY OF LA QUIN
i A
WATER HEATING BUILDING & SAFETY DEPT.
Qty. Type Gallons Min. Eff Distrib tion .r r.�ir +p Nl;=JStiatus
cr;u i-Y)IM9TRI IrTION
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-03-13 71 7:01:01 ID:
Page 3 of 19
r
•
•
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Mr. & Mrs. Jeff Hillebrand
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
3/13/2014
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
CITY OF I AQUINT r
t.9?II' z SAFETY DEPT.
j FVH1 CONSTRUCT
T
EnemyPro 5.1 by EnemySoft User Number: 6712 Run Code: 201403-13T17:01` 1 `--/0 a e 4 of 19
•
•
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Mr. & Mrs. Jeff Hillebrand
1 ❑ Multi Family m Existing+ Addition/Alteration
3/13/2014
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kgtu/ft2- r
Space Heating 14.89 14.20 0.69
Space Cooling 245.95 244.57 1.38
Fans 45.03 44.72 0.31
Domestic Hot Water 0.00 0.00 0.00
Pumps 0.00 0.00 0.00
Totals 305.87 303.50 2.37
Percent Better Than Standard: 0.8%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (E) 80 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (E) 868 160
Fuel Available at Site: Natural Gas (S) 1,324 305
Raised Floor Area: 0 (M 1,017 334
Slab on Grade Area: 2949 (N) 1,396 35
Average Ceiling Height: 12.9 Roof 2,949 16
Fenestration Average U -Factor: 0.71 TOTAL: 850
Average SHGC: 0.73 Fenestration/CFA Ratio: 28.8
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and comple
Documentation Author
Company Scott Design and Title 24, Inc,
3/13/2014
Address 77-085 Michigan Drive Name Tim Scott
City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelopeeating require
installer testing and certification and field verification by an approved HE a e.r. �4
� F
Designer or Owner (per Business & Professions Code) r
i
Company Robert A. Pitchford Design and Drafting G�ji�.I.r r" + D
Address 77-622 Country Club Dr. Suite O Name Robert Pitchford
City/State/Zip Palm Desert, Ca 92211 Phone (760) 346-2856 FSS g� dliV.� f L�c nese#� ate
DATER
�EnenqyPrz)
5.1 6 EnerSoft User Number: 6712 Run Code: 201403 -13T17:01:0; ---1D
0
•
CERTIFICATE OF COMPLIANCE:
Residential
Part 4 of 5 CF -1 R
Project Name
Mr. & Mrs. Jeff Hillebrand
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
1311312014
OPAQUE SURFACE DETAILS
Surface
T e Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof
2,747
0.049 R-19
0
20 Existing 4.2.1-A4
Existing Residence
Wall
638
0.110 R-11
80
90 Existing 4.3.1-A2
Existing Residence
Door
18
0.500 None
80
90 Existing 4.5.1-A4
Existing Residence
Wall
811
0.110,R-11
170
90 Existing 4.3.1-A2
Existing Residence
Wall
280
0.110 R-11
170
90 Removec 4.3.1-A2
Existing Residence
Wall
482
0.110 R-11
260
90 Existing 4.3.1-A2
Existing Residence
Wall
180
0.110 R-11
260
90 Removec 4.3.1-A2
Existing Residence
Wall
1,362
0.110 R-11
350
90 Existing 4.3.1-A2
Existing Residence
Slab
2,7631
0.730 None
0
180 Existing 4.4.7-A1
Existing Residence
Roof
1861
0.049 R-19
0
20 New 4.2.1-A4
Office Addition
Wall
52
0.102 R-13
80
90 New 4.3.1-A3
Office Addition
Wall
208
0.102 R-13
170
90 New 4.3.1-A3
Office Addition
Wall
201
0.102 R-13
260
90 New 4.3.1-A3
Office Addition
Slab
186
0.730 None
0
180 Existing 4.4.7-A1
Office Addition
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC
Azm Status
Glazing Type
Location/Comments
1
Skylight
16.0 0.550 Default
0.67 1 Default
0 Existing
Double Non Metal Clear
Existing Residence
2
Window
80.0 0.710 Default
0.73 1 Default
80 Existing
Double Metal Clear
Existing Residence
3
Window
9.8 0.710 Default
0.73 Default
80 Existin
Double Metal Clear
Existing Residence
4
Window
24.5 0.710 Default
0.73 Default
80 Existing
Double Metal Clear
Existing Residence
5
Window 1
9.8 0.710 Default
0.73 Default
80 Existing
Double Metal Clear
Existing Residence
6
Window
18.0 0.710 Default
0.73 Default
80 Existing
Double Metal Clear
Existing Residence
7
Window
18.0 0.710 Default
0.73 Default
80 Existing
Double Metal Clear
Existing Residence
8
Window
32.0 0.710 Default
0.73 Default
170 Existing
Double Metal Clear
Existing Residence
9
Window
8.0 0.710 Default
0.73 Default
170 Existing
Double Metal Clear
Existing Residence
10
Window
8.0 0.710 Default
0.73 Default
170 Existing
Double Metal Clear
Existing Residence
11
Window
32.0 0.710 Default
0.73 Default
170 Existing
Double Metal Clear
Existing Residence
12
Window
80.0 0.710 Default
0.73 Default
170 Existing
Double Metal Clear
Existing Residence
13
Window
25.0 0.710 Default
0.73 Default
170 Existing
Double Metal Clear
Existing Residence
14
Window
24.0 0.710 Default
0.73 Default
170 Existing
Double Metal Clear
Existing Residence
15
Window
48.0 0.710 Default
0.73 Default
170 Existing
Double Metal Clear
Existing Residence
16
Window
48.01 0.710 Default
0.73 Default
170 Existing
Double Metal Clear
Existing Residence
(1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-8 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t Wd
Ove hanq Left Fin
Len H t LExt RExt Dist Len
Ri ht Fin
Hat Dist Len H t
1
None
1.00
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
1
U
14
Bug Screen
0.76
c , ,1. �� it 2, C, IN C CD
15
Bug Screen
0.76
i
16
IBug Screen
0.76�-
I3THUCTION
EnergyPro
5.1 by EnergrySoft User Number: 6712 RunCode: 2014-03-13T17:01:01 ID:
Page 6 bf 19
Lim 1 G_ CST I I
:7
•
`CERTIFICATE OF COMPLIANCE:
Residential Part 4 of 5 CF -1 R
Project Name
Mr. &Mrs. Jeff Hillebrand
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
3/13/2014
OPAQUE SURFACE DETAILS
Surface U-
Type Area Factor
Insulation Joint Appendix
Cavity Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID
Type Area
U -Factor SHGC
Azm Status Glazing Type Location/Comments
17
Window 80.0
0.710 Default 0.73 Default
260 Existing Double Metal Clear Existing Residence
18
Window 25.0
0.710 Default 0.73 Default
260 Existing Double Metal Clear Existing Residence
19
Window 24.0
0.710 Default 0.73 Default
260 Existing Double Metal Clear Existing Residence
20
Window 10.0
0.710 Default 0.73 Default
260 Existing Double Metal Clear Existing Residence
21
Window 127.2
0.710 Default 0.73 Default
260 Existing Double Metal Clear Existing Residence
22
Window 48.01
0.710 Default 0.73 Default
Double Metal Clear Existing Residence
260rExisting
23
Window 25.0
0.710 Default 0.73 Default
350Double Metal Clear Existing Residence
24
Window 7.5
0.710 Default 0.73 Default
350Double Metal Clear Existing Residence
25
Window 2.0
0.800 NFRC 0.39 NFRC
350Glass Block Existing Residence
26
Window 20.0
0.790 Default 0.59 Default
260Dual Metal Tint Office Addition
(1) U -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
Window
SHGC Hat Wd
Ove hanq Left Fin Ri ht Fin
Len Hat LExt I RExt Dist I Len Hat Dist Len Hat
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
0.76
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
I ,
i bialLtJR%3 & ISN F
UH W046TRUCTION
EnergyPro
5.1 by EnerqySoft
User Number: 6712 Run Code: 2014-03-13T17:01:04 ID: Pa -gel 7 of 19
•
•
•
'CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5
CF -1 R
Project Name
Mr. & Mrs. Jeff Hillebrand
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
1311312014
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area
New Existing Altered Removed Volume Year Built
HVAC 1 existing Existing Residence
2,763
35,919 1989
Office Addition
186
2,232
Totalsi 1861 2,7631 0 0
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
HVAC 1 existing 2 Central Furnace
78% AFUE Split Air Conditioner 10.0 SEER Setback
Existing
HVAC DISTRIBUTION
System Name Heating
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
HVAC 1 existing Ducted
Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
WATER HEATING SYSTEMS
Sstem Name
Qty-
T e
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
CEC Standard
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
ft
0
_ o
Q —
- - -
S tfem?Name,g—
Pipe
,Len ,
Pipe Insul.
Thick.
Qtv. THP
Plenum
Outside Buried
❑
a • 1 f �1.fF L-
.
❑
(�•" t
V
❑
P 'e i, i Va.i"46
1 - RUCT
()NI
EnergyPro 5.1 by EnergySoft User Number. 6712
Run Code: 201403-13T17:01 t01 E ID:
Pale 8 of 19
4
r
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
r. & Mrs. Jeff Hillebrand
Date
3/13/2014
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (") below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all 'oints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent Ll -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent Ll -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent Ll -factor.
150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-B.
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(4)3A: Insulation is protected from damage, includingthat due to sunlight, moisture d ui =-
it ime�tx m'ainY' natio, a d Wind
§150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is e c ose"d'ent �e yd hl
conditioned space. __:�UtLuo\j-, - SAF Ep
150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating acid Cer1if cation Co`Y o_ n.
FOR CONSTRUCTION
EnergyPro 5.1 by EnergySofi User Number: 6712 Run Code: 201403-13T17:04 1p /D: Pa4e 9 of 19
4
F_'
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name Date
r. & Mrs. Jeff Hillebrand 3/13/2014
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
return lines or built -u connections for future solar heatin .
14 b 2: Outdoor ools ors as that have a heat um or as heater shall have a cover.
rand
14(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
o rammed to run onl durin off eak electric demand eriods.
50 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of 150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
§150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Wafts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Liqhting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 wafts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
..uit_DING & SAFETY DEPT.
PAS PROVED
EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 201403-13T17:01:01 ,. lD y - Pa
10 of 19
)ATE BY I
4
r
4
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
r. & Mrs. Jeff Hillebrand
1311 014
§150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§l50(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130 131 134 and 146.
§150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
`TY OF LaAk QUI N TA
BuILDINC & SAFE7Y DEPT.
PPHCiVMD
FOR CONSTRUCTION
QATF rav
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201403-13717:0.1:01 1- Page
11 of 19
4
4
4
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
r. & Mrs. Jeff Hillebrand
3/13/2014
System Name
Floor Area
HVAC 1 existing
2,949
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
Total Room Loads
COIL
CFM
4,238
COOLING PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 71,000
89,003
5,065 2,106
72,965
Total Output Btuh
142,000
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation F
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
0
0
Output Btuh/s ft 48.2
7,547
5,184
Cooling System
o
0
Output perSystem 60,000
0
0 0
0
Total Output Btuh 120,000
0
7,547
I 104,097 5,065
0
Total Output Tons 10.0
5,184
Total Output Btuh/s ft 40.7
Total Output s ft/Ton 294.9
83,333
Air System
CFM perSystem
1,900
HVAC EQUIPMENT SELECTION
Airflow cfm
3,800
Existing
94,893 0
142,000
Airflow cfm/s ft
1.29
Airflow cfm/Ton
380.0
Outside Air %
0-0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
I TIME OF SYSTEM PEAK
94,893 0 142,000
Aug 3 PM FJan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 °F 71 OF
71 OF 106 OF
0
Outside Air
0 cfm Supply Fan
Heating Coil
105 OF
3,800 cfm
ROOM
71 OF
72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112 / 78 OF 72 / 58 OF 72 / 58 OF 48 / 47 OF
10
Outside Air
C--
0 cfm
0
Supply Fan Cooling Coil
3,800 cfm
CITY®� /48 F
L.! U I N
BUILD1N(44:,S ° �A E aR°pi Tk
72 / 58 OF
A tl"" 5"'" D 7017/,57F
1 11 Tt
OAT1=
EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 201403-13T17:01:0.1___ ID age, 12 of 19
C
•
'ROOM LOAD SUMMARY
Project Name
Mr. & Mrs. Jeff Hillebrand
Date
3/13/2014
System Name
HVAC 1 existing
Floor Area
2,949
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name
Mult. CFM Sensible Latent
CFM I Sensible Latent CFM Sensible
Existing Residence Existing Residence
1 4,056 85,170 4,796
4,056 85,170 4,796 1,966 68,103
Office Addition Office Addition
1 183 3,833 269
183 3,833 269 140 4,862
JINTA
;
UiL ING & SIAEM
' Total includes ventilation load for zonal systems.
PAGE TOTAL
TOTAL'
J''k 0 G :'`d w � a 0-%%.9 r—
u
�2�38',,�89,�0,0 �, -� ,106 2,965
4,238 89'003 . ,0 5 , 06 2,965
EnemyPro 5.1 by EnemySoft User Number: 6712
RunCode: 2014-03-13T17:01:01� `-1i3 -- --- —Page 1J of 19
own
•
•
'ROOM HEATING PEAK LOADS
Project Name
Mr. & Mrs. Jeff Hillebrand
Date
3/13/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Existing Residence
Floor Area 2,763.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT 'F
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Btu/hr
Default Roof 1978 to Present
2,747.0
0.0490
46
6,192
Double Non Metal Clear
16.0
0.5500
46
405
Default Wall 1978 to 1991
3,292.1
0.1100
46
16,658
Double Metal Clear
811.8
0.7100
46
26,513
Wood Door
18.1
0.5000
46
416
Glass Block
2.0
0.8000
46
74
Slab -On -Grade
perim = 290.0
0.7300
46
9,738
Items shown with an asterisk (') denote conduction
Infiltration: 1.00 X 1.064
��
Schedule Air Sensible
Fraction
through an interior surface
X 2,763 X
Area
another roo.
r�
�"
13.00 La t0�.2iz7l,/
Height A
9ti
FOR
Pa a TOtal
59,996
A"`"��
� ii
�� agar
60d CXz r--�–,�,
`Ik I A– 'AT'
vE
f1k�tC> n,e ..�
I
���!
46 ,–_ 8,107
TOTAL HOURLY HEAT LOSS FOR ROOM f " " ' ` E) ' t 63,103
i
DATE
EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 201403-13717:01:0.1_ ID- — �� a 14 of 19
'ROOM HEATING PEAK LOADS
•Project
Name
Mr. & Mrs. Jeff Hillebrand
Date
3/13/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Office Addition
Floor Area 186.0 ft'
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
•
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT °F
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Btu/hr
R-19 Roof(R.19.2x12.16)
186.0
0.0490
46
419
R-13 Wall (W. 13.2x4.16)
461.0
0.1020
46
2,163
Dual Metal Tint
20.0
0.7900
46
727
Slab -On -Grade
perim = 30.0
0.7300
46
1,007
Items shown with an asterisk (') denote conduction
Infiltration: 1.00 X 1.064
��
Schedule Air Sensible
Fraction
through an interior surface
X 186 X
Area
another reo
�X�
12.00 X:: 1,0.30
Height v. AC
i
FOR
4,316
A P
/-
�:a6� . _
At
P ROVEILD
T
546
•
TOTAL HOURLY HEAT LOSS FOR ROOM 862
DATE BY
Energ Pro 5.1 by EnergySoft User Number. 6712 RunCode: 201403-13T17:01:01-- I^ Paae of 19
I , 4
•
r�
r}RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Mr. & Mrs. Jeff Hillebrand 3/13/2014
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Existing Residence
Outdoor Dry Bulb Temperature
112 OF
Floor Area
2, 763.0 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
70 OF
Outdoor Daily Ranqe:
34 OF
Opaque Surfaces
Default Roof 1978 to Present
Default Wall 1978 to 1991
Wood Door
Default Wall 1978 to 1991
Default Wall 1978 to 1991
Default Wall 1978 to 1991
Orientation
(E)
(S)
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
c
=
=
c
=
=
=
=
=
2,747.0
0.0490
56.0
637.8
0.1100
32.1
18.1
0.5000
32.1
811.0
0.1100
27.1
481.8
0.1100
32.6
1,361.5
0.1100
29.0
0.0
41.3
9.8
80.2
0.0
41.3
18.0
80.2
0.0
41.3
18.0
Page Total
Fanacfrafinn
Skylight
Window existing2
Window Existing3
Window Existing4
Window Existing5
Window Existing6
Window Existing6
Window Existing8
Window Existing9
Internal Gain
(Arianfafinn
(N)
(E)
(E)
(E)
(E)
(E)
(E)
(S)
(S)
Shaded Unshaded
Btu/hr
7, 538
2,253
291
2,419
1, 725
1 18,5681
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
_
=
_
_
c
_
0
_
0.0
36.7
16.0
127.4
0.0
41.3
80.0
80.2
0.0
41.3
9.8
80.2
0.0
41.3
24.5
80.2
0.0
41.3
9.8
80.2
0.0
41.3
18.0
80.2
0.0
41.3
18.0
80.2
0.0
41.3
32.0
45.2
0.0
41.3
8.0
45.2
Page Total
4.0 Occupants X 230 Btuh/occ. -
1.0 Dwelling Unit X 1,600 Btu =
Infiltration: 1.064 X 0.94 X 171.09 X 42
Air Sensible CFM ELA AT
2,038
6,417
786
1.965
786
1,444
1,444
1,445
361
16,6871
tstuinr
920
1,600
1 7.1511
[TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM R5 nn
Latent Gain
Occupants 4•o Occupants X°1U "tu.;i^Ilw o,L AQU
Infiltration: x,771 X o.s4 X n1.os X 0.00523 - BUILDING & SAFETY
Air Sensible CFM ELA AW Af.,Y4 ROVEI
FOUR CON TPI It _Tar
Btu/hr
• 3,
4+ 1 I
0
•
•
'RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Mr. & Mrs. Jeff Hillebrand 3/13/2014
ROOM INFORMATION DESIGN CONDITIONS
Room Name Existing Residence Outdoor Dry Bulb Temperature 112 OF
Floor Area 2,763.0 ft2 Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranae: 34 OF
Surfaces Orientation
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
GLF
c
=
_
_
c
_
c
c
0.0
41.3
8.0
45.2
0.0
41.3
32.0
45.2
0.0
41.3
80.0
45.2
0.0
41.3
25.0
45.2
0.01
41.3
24.0
45.2
0.0
41.3
48.0
45.2
0.0
41.3
48.0
Page Total
Fenestratinn
Window Existingl0
Window Existing 11
Window ex12
Window ex13
Window ex 14
Window ex15
Window ex16
Window ex17
Window ex18
Orientatinn
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
c
=
_
_
c
_
c
c
0.0
41.3
8.0
45.2
0.0
41.3
32.0
45.2
0.0
41.3
80.0
45.2
0.0
41.3
25.0
45.2
0.01
41.3
24.0
45.2
0.0
41.3
48.0
45.2
0.0
41.3
48.0
45.2
0.0
41.3
80.0
83.0
0.0
41.3
25.0
83.0
Page Total
Btu/hr
0
Btu/hr
361
1,445
3,612
1,129
1,084
2,167
2,167
6,642
2,076
20,684
Internal Gain Btu/hr
Occupants 4.0 Occupants X 230 Btuh/occ. - 920
Equipment 1.0 Dwelling Unit X 1,600 Btu - 1,600
Infiltration: 1.064 X 0.94 X 171.09 X 42 = 7,151
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 85.170
Latent Gain Btu/hr
Occupants 4.0 Occupants X ,^ 13oc'� 1 �f 800
�•d
Infiltration: 4,771 X 0.94 X 171.09 X 0.00523="�UILDING & SA EYDE 3,996
Air Sensible CFM ELA AW f� P t VE D
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM N ' I Toa
•
f �
U
'RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Mr. & Mrs. Jeff Hillebrand
3/13/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Existing Residence
Outdoor Dry Bulb Temperature
112 OF
Floor Area 2,763.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U -Factor
CLTD'
Btu/hr
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
Page Total
o
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF
Area GLF
Btu/hr
Window ex19 (W) 0.01 X 41.3 +
24.0 X 83.0 =
1,993
Window ex20 2109 0.0 X 41.3 +
10.0 X 83.0 =
830
Window ex21 (W) 0.0 X 41.3 +
127.2 X 83.0 =
10,561
Window ex22 0.0 X 41.3 +
48.0 X 83.0 =
3,985
WindowExisting23 (N) 0.0 X 41.3 +
25.0 X 64.8 =
1,619
Window Existing4 (N) 0.0 X 41.3 +
7.5 X 64.8 =
486
Window Existing25 (N) 0.0 X 30.5 +
2.0 X 43.0 =
86
X +
X -
X 1 +1
X -
Page Total
19,560
Internal Gain
Btu/hr-
tu/hrOccu
Occupants
ants 4.0 Occupants X
230 Btuh/occ. =
920
Equipment 1.0 Dwelling Unit X 1,600 Btu =
1,600
Infiltration: 1.064 X 0.94 X 171.09 X 42 =
7,151
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
85,170
Latent Gain
Occupants 4.0 Occupants X �2 �� "" `
tuhhoCC. -�
00
I DI�lC & SAF ETY DEPT
Infiltration: 4,771 X 0.94 X 171.09 X 0.00523 ='
AP1aPw0�E
3, 96
Air Sensible CFM ELA ow I
FOR CONSTRUCTION
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
4.7961
'J
BY
EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 201403-13717:01:01
19
4 6 3
C
C
L—A
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Mr. & Mrs. Jeff Hillebrand
3/13/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Office Addition
Outdoor Dry Bulb Temperature
112 OF
Floor Area 186.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U -Factor
CLTD'
Btu/hr
R-19 Roof(R.19.2x12.16) (N) 186.0 X 0.0490
X 56.0 =
510
R-13 Wall (W. 13.2x4.16) (E) 52.0 X 0.1020
X 32.1 =
170
R-13 Wall (W. 13.2x4.16) (S) 208.0 X 0.1020
X 27.1 =
575
R-13 Wall (W. 13.2x4.16) (W) 201.0 X 0.1020
X 32.6 =
667
X
X =
X
X =
X
X =
X
X =
X
X =
Page Total
1,923
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF
Area GLF
Btu/hr
tArindow.26 (W) 0.0 X 37.7 +
20.0 X 71.4
= 1,429
X +
X
-
X +
X
-
X +
X
-
X +
X
-
X +
X
-
X +
X
-
X +
X
-
X +
X
-
Page Total
1,429
Internal Gain
Btu/hr—
tu/hrOccu
Occupants
ants 0.0 Occupants X 23o
Btuh/occ.
0
Equipment 0.0 Dwelling Unit X 1,600
_
Btu -
0
Infiltration: 1.064 X 0.94 X 11.52 X 42 =
481
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
CffYO F LA
UUIN I
Latent Gain
Occupants 0.0 Occupants X 2
MOW= 9i`�� &Spy
0
s'4 tib{
0
Infiltration: 4,771 X 0.94 X 11.52 X 0.00523 =
�SA-N
��c o kcONSTR
69
Air Sensible CFM ELA AW
BY
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
BATE
EnergyPro 5.1 by EnerqvSoft User Number: 6712 Run Code: 201403-13717:01:01 ID:
Pae 19 of 19