10-0631 (RER)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
10-00000631
Property Address:
56665 MERION
APN:
762-023-024- - -
Application description:
REMODEL - RESIDENTIAL
Property Zoning:
LOW DENSITY RESIDENTIAL
Application valuation:
- 40000
Applicant:
j",eohkz,Ar
T4ht 4 4 Q"
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Architect or Engineer-
LICENSED
ngi�
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
Jjcense Class: B License No.: 684857
�//Dater ontractor:
OWNE. ECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he.or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
1 ) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the -performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
I
1
LQPERMIT
Owner:
JEFF & NINI HILLEBRAND
56-665 MERION
LA QUINTA, CA 92253
Contractor:
EDWARDS CONSTRUCTION INC
51455 DESERT CLUB DRIVE
LA QUINTA, CA 92253
(760)777-8202
Lic. No.: 684857
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 8/19/10
it
---3
r , �a
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
(( �� Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier GRANITE STATE Policy Number WC 555-61-55
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any man ecome subject to the workers' compensation laws of California,
and agree that, if hould become su he workers' compensation provisions of Section
D 3700 of the Labor mply with those provisions.
Datep ✓pplicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERA NLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ON HUNDRED THOUSAND
DOLLARS 1$100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
9Ythis county to enter upon the above-mentioned property for inspection purposes.
Date: 01 Signature (Applicant or Agent):
Application Number . . . . . 10-00000631
------ Structure Information 73 SF PATIO CONV TO'LIVING -----
Construction Type . . . . . TYPE V, UNPROTECTED
Occupancy Type . . . . . . DWELLG/LODGING/CONG <=10
Flood Zone . . . . . NON -AO FLOOD ZONE
Other struct info . . . . . CODE EDITION 2007/08 energy
# BEDROOMS .00
----------------------------------------------------------------------------
Permit BUILDING PERMIT
Additional desc .
Permit Fee . . . . 349.50 Plan Check Fee 227.18
Issue Date . . . . Valuation 40000
Expiration Date 2/15/11
Qty Unit Charge Per Extension
BASE FEE 252.00
15.00 6.5000 THOU BLDG 25,001-50,000 97.50
----------------------------------------------------------------------------
Permit
Additional desc .
Permit Fee . . .
Issue Date . . .
Expiration Date .
ELECT - ADD/ALT/REM
34.50
2/15/11
Plan Check Fee . . 8.63
Valuation . . . . 0
Qty Unit Charge Per . Extension
BASE FEE 15.00
26.00 .7500 PER ELEC DEVICE./FIXTURE 1ST 20 19.50
-----------------------------------7----------------------------------------
Permit MECHANICAL'
Additional desc .
Permit Fee . . . . 39.00 Plan Check Fee 9.75
Issue Date Valuation . . . . 0
Expiration Date . . . 2/15/11
Qty Unit
Charge Per
Extension
BASE FEE
15.00
1.00
4.5000 EA
MECH'VENT INST/ DUCT ALT
4.50
3.00
6.5000 EA
MECH VENT FAN
19.50
-----------7----------------------------------------------------------------
Special Notes
and Comments
REMODEL OF WINDOWS AND 73 SF
PATIO
CONVERSION TO
FAMILY RM. TYPE
V -B
CONSTRUCTION.
R-3 OCCUPANCY.
2007 CODES
2008 ENERGY.
----------------------------------------------------------------------------
Other Fees .
. . . . ... .
. BLDG'STDS ADMIN (SB1473)
2.00
LQPERMIT'
Application Number . . . . . 10-00000631
----------------------------------------------------------------------------
Other Fees . . . . . . . . . ENERGY REVIEW FEE. 22.72
. STRONG MOTION (SMI) - RES 4.00
Fee summary
-----------------
Permit Fee Total
Plan Check Total
Other Fee Total
Grand Total
LQPERMIT
Charged Paid
423.00 .00
245.56 .00
28.72 .00
697.28 .00
Credited Due
.00 423.00
.00 245.56
.00 28.72
.00 697.28
VW
Bin #
c4y of La Qu►nta
Building 8r Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
f _ 1
Project Address: �'� �`j R !^('j/v
Owner's Name:7EE J- r
1
A. P. Number: 76 006 0
Address:
Legal Description: I j4qZ
Contractor: "
City, ST, Zip: g�25
Telephone:``?a
Address: ), IIS -S7 2,--s A- CLU16
Project Description: A� 73 TO
City, ST, Zip: L �
-....gzzs.
C
Telephone: 7 0. 777 8Z
'> ; ; a >v;> : >:s <> k v::: s;:
Lie. #;
}p 'e� %
State Lie. #: `� O SCity
j CW1 ,z� �j
h/
Arch., Engr., Designer: ��G�
p
e ty .A �) R /1 e� ��i� C
NC o 6
Address:
PILI .!�-2. �Scl,�e °O
� Na 64S GdNC Av �t�T :�Shci4%'%�.✓
City., ST, Zip:
Telephone:
P �j'� z:;.,>.<:: :'<:, .:sz .•:<:>W:.:f::«
State Lie. #•
Name of Contact Person: L L
Construction e: Occupancy:
Yp ✓ /IiA- tQ )
Project type (circle one): New Add' Alt Repair Demo
Sq. Ft.:, # Stories:
# Units:
Telephone # of Contact Person: 70- %,�-/35/ 7 72.,99071
Estimated Value of Project: /Zo ,o del - z0a 000
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING i
iN PERMIT FEES
Plan Sets
Plan Check submitted,,
(IItem
Amount
Structural Calcs.
y
Reviewed, ready f correctionsan
s
q 2
/Pl Check Deposit
Truss Calcs.
Called Contact Person �..
2
Plan Check Balance,
Title 24 Cates.
P P _ t0�� -
Plansicked u
- .—��
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2e° Review, ready for corrections issuePh
I
Electrical
Subcontactor List
Called Contact Person
8
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'"' Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
. Zj
T1 5
/ ,ice .
Z
lli g Srle• RSC , 8//P� Quo.
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 73 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Exempt - Ed Randall Check No.
Name on the check Telephone 760-972-9607
Funding Exempt
By Dr. Sharon P. McGehee
Superintendent
Fee collected lexempt�ed by Sh on . CG v ey Payment Recd $0 0!)
Ovi 7716nderr,,
C
;
Signature
NOTICE: Pursuant to Government Code Section 66020(d)(1), this wi a to notify you that the 90 -day approval period in which you may protest the fees
or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road
¢ BERMUDA DUNES O
Date
8/19/10
La Quinta, CA 92253�I"
En RANCHO MIRAGE
WELLS
No.
30802
(760) 771-8515
,INDIAN
DESERT
�v PLA nU1NTA ,
�yQwolo
L�
Owner
Jeffrey Hillebrand
APN #
762-023-024
Address
56665 Merion
Jurisdiction
La Quinta
City
La Quinta Zip
Permit #
Tract #
No. of Units
1
Type
Residential Addition
Lot # No. Street
S.F. Lot # No.
Street S.F.
Unit 1
56665 Merton
73 Unit 6
Unit 2
Unit 7
Unit 3
Unit 8
Unit 4
Unit 9
Unit 5
Unit 10
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 73 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Exempt - Ed Randall Check No.
Name on the check Telephone 760-972-9607
Funding Exempt
By Dr. Sharon P. McGehee
Superintendent
Fee collected lexempt�ed by Sh on . CG v ey Payment Recd $0 0!)
Ovi 7716nderr,,
C
;
Signature
NOTICE: Pursuant to Government Code Section 66020(d)(1), this wi a to notify you that the 90 -day approval period in which you may protest the fees
or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
0
0
I BUILDING ENERGY ANALYSIS REPORT I
PROJECT:
Mr. & Mrs. Jeff Hillebrand
56-665 Mericon
La Quinta, CA 92253
Project Designer:
Robert A. Pitchford Design and Drafting
77-622 Country Club Dr. Suite O
Palm Desert, Ca 92211
(760) 346-2856
Report Prepared by:
Jon Scott
Scott Design and Title 24, Inc,
.77-085 Michigan Drive
Palm Desert, Ca 92211
(760) 200-4780
Job Number:
Date:
8/3/2010
�I �l
a��rs
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE I 7�[fl BYa
IIECEIVF,D
M
AUG 04 2010
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
.' This program developed by EnergySoft, LLC — www.energysoft.com.
EnerovPro 5.1 by EnerovSoft User Number: 6712 RunCode: 2010-08-03T09:11:56 /D:
Ah
•
•
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Mr. & Mrs. Jeff Hillebrand
Building Type m Single Family ❑ Addition Alone
O Multi Family m Existing+ Addition/Alteration
Date
8/3/2010
Project Address
56-665 Mericon La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,836
Addition
73
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes El No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity f Features see Part 2 of 5 Status
Roof Wood Framed Attic
R-19 2,763 Existing
Wall Wood Framed
R-11 1,955 Existing
Door Opaque Door
None 18 Existing
Slab Unheated Slab -on -Grade
None 2,836 Perim = 310' Existing
Roof Wood Framed Attic
R-19 73 New
Wall Wood Framed
R-13 58 New
FENESTRATION U-
Orientation Area(ft) Factor
Exterior
SHGC Overhang Sidefins Shades Status
Front (E) 80.0 0.790
0.59 none none Bug Screen Altered
Front (E) 80.3 0.710
0.73 none none Bug Screen Existing
Left (S) 80.0 0.710
0.73 none none Bug Screen Existing
Left (S) 200.0 0.790
0.59 none none Bug Screen New
Rear (1M 206.0 0.790
0.59 none none Bug Screen New
Right (N) 32.5 0.710
0.73 none none Bug Screen Existing
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
2 Central Furnace 80% AFUE
Split Air Conditioner 16.0 SEER Setback
Altered
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC 1 Altered Ducted
Ducted Attic, Ceiling Ins, vented 4.2
Existing
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
Energ Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2010-08-03T09:11:5 ID:
Page 3 of 18
PERFORMANCE CERTIFICATE: Residential . (Part 2 of 5) CF -1 R
Project Name
Mr. & Mrs. Jeff Hillebrand
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
8/3/2010
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
The Cooling System CZE038/CZH0481YPLC0BOB 121YPLC080B 16 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify
the installation of the correct Condenser.
The HVAC System HVAC 1 Altered incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
Ene Pro 5.1 by EnemySoft User Number. 6712 RunCode: 2010-08-03T09:11:5 ID: Page 4 of 18
•
0
•
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Mr. & Mrs. Jeff Hillebrand
❑ Multi Family m Existing+ Addition/Alteration
$/3/2010
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 7.41 8.80 -1.39
Space Cooling 136.22 117.44 18.78
Fans 26.71 34.86 -8.15
Domestic Hot Water 0.00 0.00 0.00
Pumps 0.00 0.00 0.00
Totals 170.33 161.10 9.23
Percent Better Than Standard: 5.4
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (E) 80 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (E) 525 160
Fuel Available at Site: Natural Gas (S) 923 280
Raised Floor Area: 0 NO 506 206
Slab on Grade Area: 2,836 (N) 756 33
Average Ceiling Height: 11.9 Roof 2,836 0
Fenestration Average U -Factor: 0.77 TOTAL: 679
Average SHGC: 0.63 Fenestration/CFA Ratio: 23.9%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Scott Design and Title 24, Inc,
8/32010
Address 77-085 Michigan Drive Name Jon Scott 1::S�—
City/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelopes aling require
installer testing and certification and field verification by an approved HERS rater:
Designer or Owner (per Business & Professions Code)
Company Robert A. Pitchford Design and Drafting
Address 77-622 Country Club Dr. Suite O Name Robert Pitchford
City/State/Zip Palm Desert, Ca 92211 Phone (760) 346-2856 Signed License # Date
EneMVPro 5.1 by EneMySoft User Number: 6712 RunCode: 2010-08-03T09:11:5 /D: Page 5 of 18
L7,
r -1q
i
CERTIFICATE OF COMPLIANCE: Residential
(Part 4 of 5) CF -1 R
Project Name
Mr. & Mrs. Jeff Hillebrand
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
$/3/2010
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm I Tilt Status 4 Location/Comments
Roof
2,763
0.049 R-19
0
20 Existing 4.2.1-A4
Existing Residence
Wall
347
0.110 R-11
80
90 Existing 4.3.1-A2
Existing Residence
Door
18
0.500 None
80
90 Existing 4.5.1-A4
Existing Residence
Wall
6211
0.110 R-11
170
90 Existing 4.3.1-A2
Existing Residence
Wall
80
0.110 R-11
170
90 Removec 4.3.1-A2
Existing Residence
Wall
264
0.110 R-11
260
90 Existing 4.3.1-A2
Existing Residence
Wall
99
0.110 R-11
260
90 Removec 4.3.1-A2
Existing Residence
Wall
724
0.110 R-11
350
90 Existing 4.3.1-A2
Existing Residence
Slab
2,763
0.730 None
0
180 Existing 4.4.7-A1
Existing Residence
Roof
73
0.049 R-19
0
20 New 4.2.1-A4
Addition
Wall
221
0.102 R-13
170
90 New 4.3.1-A3
Addition
Wall
361
0.102 R-13
260
90 New 4.3.1-A3
Addition
Slab
73
0.730 None
0
180 Existing 4.4.7-A1
Addition
FENESTRATION SURFACE DETAILS
ID
Type I
Area LI-Factorl
SHGC
Azm Status
Glazing Type
Location/Comments
1
Window
80.0 0.790 Default
0.59 Default
80 Altered
Dual Metal Tint
Existing Residence
2
Existing
0.710 Default
0.73 Default
Double Metal Clear
pre -altered for above
3
Window
9.9 0.710 Default
0.73 Default
80 Existing
Double Metal Clear
Existing Residence
4
Window
24.5 0.710 Default
0.73 Default
80 Existing
Double Metal Clear
Existing Residence
5
Window
9.9 0.710 Default
0.73 Default
80 Existing
Double Metal Clear
Existing Residence
6
Window
18.0 0.710 Default
0.73 Default
80 Existing
Double Metal Clear
Existing Residence
7
Window
18.0 0. 7101 Default
0.73 Default
80 Existing
Double Metal Clear
Existing Residence
8
Window
32.0 0.710 Default
0.73 Default
170 Existing
Double Metal Clear
Existing Residence
9
Window
8.0 0.710 Default
0.73 Default
170 Existing
Double Metal Clear
Existing Residence
10
Window
8.0 0.710 Default
0.73 Default
170 Existing
Double Metal Clear
Existing Residence
11
Window
32.0 0.710 Default
0.73 Default
170 Existing
Double Metal Clear
Existing Residence
12
Window
80.0 0.710 Default
0.73 Default
170 Removed Double Metal Clear
Existing Residence
13
Window
25.0 0.710 Default
0.73 Default
170 Removed Double Metal Clear
Existing Residence
14
Window
80.0 0.790 Default
0.59 Default
170 New
Dual Metal Tint
Existing Residence
15
Window
48.0 0.710 Default
0.73 Default
170 Removed Double Metal Clear
Existing Residence
16
Window
24.0 0.790 Default
0.59 Default
170 New
Dual Metal Tint
Existing Residence
(1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Window
Exterior Shade Type SHGC H t Wd
Ove hang Left Fin
Len H t LExt RExt Dist Len
Right Fin
H t Dist Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
JBug Screen
0.76
16
JBug Screen
1 0.76
EnergyPro
5.1 by
EnergySoft User Number.' 6712
RunCode: 2010-08-03T09:11:5 ID:
Pa e 6 of 18
n
•
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R
Project Name Building Type m Single Family ❑ Addition Alone Date
Mr. & Mrs. Jeff Hillebrand ❑ Multi Family m Existing+ Addition/Alteration $/3/2010
OPAQUE SURFACE DETAILS
Surface U- I InsulationJoint Appendix
Tvne Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
'ENESTRATION SURFACE DETAILS
ID Type Area U -Factor
SHGC
Azm Status
Glazing Type
Location/Com
17
Window
48.0
0.710 Default
0.73 Default
170 Removed
Double Metal Clear
Existing Residence
18
Window
48.0
0.790 Default
0.59 Default
170 New
Dual Metal Tint
Existing Residence
19
Window
80.0
0.710 Default
0.73 Default
260 Removed Double Metal Clear
Existing Residence
20
Window
25.0
0.710 Default
0.73 Default
260 Removed
Double Metal Clear
Existing Residence
21
Window
80.0
0.790 Default
0.59 Default
260 New
Dual Metal Tint
Existing Residence
22
Window
24.0
0.710 Default
0.73 Default
260 Removed
Double Metal Clear
Existing Residence
23
Window
10.0
0.710 Default
0.73 Default
260 Removed Double Metal Clear
Existing Residence
24
Window
48.0
0.710 Default
0.73 Default
260 Removed
Double Metal Clear
Existing Residence
25
Window
48.0
0.710 Default
0.73 Default
260 Removed Double Metal Clear
Existing Residence
26
Window
63.0
0.790 Default
0.59 Default
260 New
Dual Metal Tint
Existing Residence
27
Window
25.0
0.710 Default
0.73 Default
350 Existing
Double Metal Clear
Existing Residence
28
Window
7.5
0.710 Default
0.73 Default
350 Existing
Double Metal Clear
Existing Residence
29
Window
48.0
0.790 Default
0.59 Default
170 New
Dual Metal Tint
Addition
in
Window
63.0
0.790 Default
0.59 Default
260 New
Dual Metal Tint
Addition
(1) LI -Factor Type: 116-A = Default Table from Standards, NrHU = Laoeieo vdiue
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
Window Overhang Left Fin Ri ht Fin
ID Exterior Shade Type SHGC H t Wd Len H t LExt RExt Dist Len H t Dist Len H t
17
Bug Screen
V.10
18
JBug Screen
0.76
19
JBug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
0.76
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
25
Bu Screen
0.76
26
Bu Screen
0.76
27
Bu Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.761 1
30
Bu Screen
1 0.76
EnergyPro,
5.1 by EnemySoft
User Number., 6712 RunCode: 2010-08-03T09:11:5 ID: Pae 7 of 18
•
•
C7
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R
Project Name
Mr. & Mrs. Jeff Hillebrand
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
$/3/2010
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area ff
New Existinq Altered Removed Volume Year Built
HVAC 1 Altered Existing Residence
2,763 33,156 1989
Addition
73 657
Totals 73 2,763 0 0
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
HVAC 1 Altered 2 Central Furnace
80% AFUE Split Air Conditioner 16.0 SEER Setback Altered
pre -altered for above Central Furnace
78% AFUE Split Air Conditioner 10.0 SEER Setback
HVAC DISTRIBUTION
System Name Heating
Duct Ducts
Cooling Duct Location R -Value Tested? Status
HVAC 1 Altered Ducted
Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing
pre -altered for above Ducted
Ducted Attic, Ceiling Ins, vented 4.2 ❑
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
(Btu h)
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
CEC Standard
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
E
E
w
Hot Water Piping Length
(ft)o
2 .2
Q —
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qt . HP
Plenum
Outside Buried
❑
❑
❑
❑
❑
❑
❑
❑
EnergyPro 5.1 by EnerqySoft User Number: 6712
RunCode: 2010-08-03T09:11:5 ID: Page 8 of 18
4
4
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
r. & Mrs. Jeff Hillebrand
Date
8/3/2010
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested, labeled, and installed according to ASTM El677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
e ui ed with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASH RAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-13.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoff User Number. 6712 RunCode: 2010-08-03709:11:56 /D: Page 9 of 18
4
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Mr. & Mrs. Jeff Hillebrand
8/3/2010
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2010-08-03709:11:56 /D: Page 10 of 18
r
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Mr. & Mrs. Jeff Hillebrand
8/3/2010
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySofi User Number. 6712 RunCode: 2010-08-03709:11:56 /D: Page 11 of 18
r
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
r. & Mrs. Jeff Hillebrand
Date
8/3/2010
System Name
HVAC 1 Altered
Floor Area
2,836
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
COIL
CFM
Total Room Loads 4,408
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation o
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 71,000
67,531
5,701 1,341
59,663
Total Output Btuh 142,000
0
Output Btuh/s ft 50.1
5,726
4,239
Cooling System
01
0
Output per System 43,000
0
0 0
0
Total Output (Btuh) 86,000
0
5,701
0
Total Output ons 7.2
5,726
4,239
Total Output Btuh/s ft 30.3
Total Output s ftrron 395.7
1 78,984
68,141
Air System
CFM per System
1,500
HVAC EQUIPMENT SELECTION
Airflow cfm
3,000
CZE038/CZH048/YPLC080B12/YPLC080B16 57,409
13,762
142,000
Airflow cfm/s ft 1.06
Airflow cfm/Ton
418.6
Outside Air %
0.0%
Total Adjusted System Output 57,409
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
13,762
Aug 3 PM
142,000
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 71 OF
0
Outside Air
0 cfm Supply Fan
3,000 cfm
71 OF
71 OF 115 OF
Pi
Heating Coil
114 OF
ROOMRI
72 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 72/60°F 72/61°F 54/53°F
Outside Air
0 cfm Supply Fan Cooling Coil 56 ! 54 OF
3,000 cfm 55.6 �� R,OOIY �
I
72 / 60 OF 70 ! 60 OF
I
EnergyPro 5.1 by EnergySoff
User Number: 6712 RunCode: 2010-08-03T09:11:56 /D:
Page 12 of 18
•
•
•
I ROOM LOAD SUMMARY
r
8/3/2010
2,836
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible I Latent CFM Sensible Latent CFM Sensible
Existing Residence Existing Residence 1 3,785 57,983 4,796 3,785 57,983 4,796 1,220 54,307
Addition Addition 1 1 6231 9,5491 906 623 9,549 906 120 5,356
1 .
for zonal
PAGE TOTAL
TOTAL'
4,408 67,531
5,701
1,341
59,663
4,4081 67,531
5,701
1,341
59,663
13 of 18
•
C7
ROOM HEATING PEAK LOADS
Project Name781312
Mr. & Mrs. Jeff Hillebrand
ate
010
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Existing Residence
Floor Area 2,763.0 ft'
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT `F
=
=
=
=
=
=
46
Btu/hr
Default Roof 1978 to Present
2, 763.0
0.0490
46
6,228
Default Wall 1978 to 1991
2,134.1
0.1100
46
10,799
Dual Metal Tint
375.0
0.7900
46
13,628
Double Metal Clear
192.8
0.7100
46
6,297
Wood Door
18.1
0.5000
46
416
Slab -On -Grade
perm = 290.0
0.7300
46
9,738
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 2,763 X
Area
another room
12.00 X 0.300
Height ACH
Page Total
/60] X
AT
47,105
= 8,107
TOTAL HOURLY HEAT LOSS FOR ROOM 54,307
EnergyPro 5.1 by EnergySoft User Number.- 6712 RunCode: 2010-08-03T09:11:5 ID: Page 14 of 18
•
LJ
ROOM HEATING PEAK LOADS
Project Name
'Mr. & Mrs. Jeff Hillebrand
Date
8/3/2010
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Addition
Floor Area 73.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
U -Value
X 0.0490
X 0.1020
X 0.7900
X 0.7300
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X L
to another room
9.00 X 0.400
Ceiling Height ACH
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT *F
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-19 Roof(R. 19.2x 12.16)
73.0
46
165
R-13 Wall (W. 13.2x4.16)
58.0
46
272
Dual Metal Tint
111.0
46
4,034
Slab -On -Grade
perim = 20.0
46
672
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 73 X
Area
Page Total
/60] X
AT
5,142
= 214
TOTAL HOURLY HEAT LOSS FOR ROOM 5,356
EnergyPro 5.1 by EnergySoft User Number., 6712 RunCode: 2010-08-03T09:11:5 /D: Page 15 of 18
r�
LJ
•
I RESIDENTIAL ROOM COOLING LOAD SUMMARY
Mr. & Mrs. Jeff Hillebrand 1 8/3/2010
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Existing Residence
Outdoor Dry Bulb Temperature
112 OF
Floor Area
2, 763.0 ftZ
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
70 OF
Outdoor Dailv Ranae:
34 OF
ODaaue Surfaces
Default Roof 1978 to Present
Default Wall 1978 to 1991
Wood Door
Default Wall 1978 to 1991
Default Wall 1978 to 1991
Default Wall 1978 to 1991
Orientation
(E)
(E)
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
2,763.0
0.0490
56.0
346.6
0.1100
32.1
18.1
0.5000
32.1
621.0
0.1100
27.1
264.01
0.1100
32.6
723.5
0.1100
29.0
1,965
0.0
41.3
9.9
X
80.2
=
794
0.0
41.3
18.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
Window A/teredl
Window Existing2 Ed
Window Existing3
Window Existing4
Window Existing5
Window Existing6
Window Existing7
Window Existing8
Window Existing9
Orientation
(E)
(E)
(E)
(E)
(E)
(E)
(S)
(S)
(S)
Btu/hr
7,582
1,224
291
1,852
2,
14,
Shaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Unshaded
Area
GLF
X 69.2 =
Btu/hr
0.0
37.7
80.0
5,532
0.0
41.3
9.9
X
80.2
=
794
0.0
41.3
24.5
X
80.2
=
1,965
0.0
41.3
9.9
X
80.2
=
794
0.0
41.3
18.0
X
80.2
=
1,444
0.0
41.3
18.0
X
80.2
=
1,444
0.0
41.3
32.0
X
45.2
=
1,445
0.0
41.3
8.0
X
X
45.2
=
=
361
0.0
41.3
8.0
45.2
361
Page Total
14,141
Internal Gain Btu/hr-
Occupants
tu/hrOccu ants 4.0 Occupants X 230 Btuh/occ. = 920
Equipment 1.0. Dwelling Unit X 1,600 Btu 1,600
Infiltration: 1.064 X 0.94 X 171.09 X 42 = 7,151
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 57.9831
Laient Gain Btu/hr
Occupants Occupants X 200 Btuh/occ. = 800
Infiltration: 4,771 X 0.94 X 171.09 X 0.00523 = 3,996
Air Sensible CFM ELA AW
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4 7qal
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Mr. & Mrs. Jeff Hillebrand
1 8/3/2010
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Existing Residence
Outdoor Dry Bulb Temperature
112 OF
Floor Area 2,763.0 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range-
34 OF
Opaque Surfaces Orientation Area U -Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
o
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF Area
GLF
Btu/hr
Window Existingl0 (S) 0.0 X 41.3 +
32.0
X 45.2
= 1,445
Window 13 (S) 0.0 X 37.7 +
80.0
X 40.8
= 3,266
Window 15 (S) 0.0 X 37.7 +
24.0
X 40.8
= 980
Window 17 (S) 0.0 X 37.7 +
48.0
X 40.8 .=
1,959
Window 20 (W) 0.0 X 37.7 +
80.0
X 71.4
= 5,714
Window.5-25 W 0.0 X 37.7 +
63.0
X 71.4
= 4,500
Window Existing26 (N) 0.0 X 41.3 +
25.0
X 64.8
= 1,619
Window Existing27 (N) 0.0 X 41.3 +
7.5
X 64.8
= 486
X +
X
-
Page Total
19,968
Internal Gain
Btu/hr-
tu/hrOccu
ants 4.0 Occupants X 230
Occupants
Btuh/occ.
=
920
Equipment 1.0 Dwelling Unit X 1,600
Btu
=
1,600
Infiltration: 1.064 X 0.94 X 171.09 X 42 =
7,151
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
57,983
Latent Gain
Btu/hr
Occupants 4.0 Occupants X 200
Btuh/occ.
=
800
Infiltration: 4,771 X 0.94 X 171.09 • X 0.00523 =
3,996
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
4,796
Ene-mvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2010-08-03T09:11:5 /D:
Pae 17 of 18
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Mr. & Mrs. Jeff Hillebrand
1 8/3/2010
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Addition
Outdoor Dry Bulb Temperature
112 OF
Floor Area 73.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U -Factor
CLTD'
Btu/hr
R-19 Roof(R. 19.2x 12.16) (N) 73.0 X 0.0490
X
56.0 =
200
R-13 Wall (W. 13.2x4.16) (S) 22.0 X 0.1020
X
27.1 =
61
R-13 Wall (W. 13.2x4.16) 36.0 X 0.1020
X
32.6 =
120
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
381
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF
Area
GLF
Btu/hr
Window28 (S) 0.0 X 37.7 +
48.0
X 40.8
= 1,959
Wndow.5-29 NO 0.0 X 37.7 +
63.0
X 71.4
= 4,500
X +
X
-
X +
X
-
X +
X
-
X +
X
-
X +
X
-
X +
X
-
X +1
X
-
Page Total
6,459
Internal Gain
Btu/hr
Occupants 4.0 Occupants X 230
Btuh/occ.
=
920
Equipment 1.0 Dwelling Unit X 1,600
Btu
=
1,600
Infiltration: 1.064 X 0.94 X 4.52 X 42 =
189
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
9,549
Latent Gain
Btu/hr
Occupants 4.0 Occupants X 200
Btuh/occ.
=
800
Infiltration: 4,771 X 0.94 X 4.52 X 0.00523 =
106
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
906
EnemvPro 5.1 by EnemySoft User Number.- 6712 RunCode: 2010-08-03T09:11:5 /D:
Pae 18 of 18