12-0916 (AR)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: 12=.00000916
Property Address: --56965 MERION
APN: 762 -031 -004 -
Application description: ADDITION - RESIDENTIAL
Property Zoning: LOW DENSITY RESIDENTIAL
Application valuation: 30000
Tu!t�440"
Applicant: Architect or Engineer:
N -
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
LICENSED CONTRACTOR'S DECLARATION
I hereby affir under penalty of per' h I a 'tensed under provisions of Chapter 9 (commencing with
Section 0 1 of Division 3 of the usi e s 2 rof ssionals Co e, and my License is in full force and effect.
License I B C2�7 _ Lice a No.: 684857
--'--Date: ✓Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500):
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.l.
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_ 1 I am exempt under Sec. B.&P.C. for this reason
/-Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERMIT
Owner:
SCHENKEL, JONATHAN & SHELLY
1904 BROWNING WAY
SANDPOINT, ID 83864
Contractor:
EDWARDS CONSTRUCTION INC, BOB
51455 DESERT CLUB DRIVE
LA QUINTA, CA 92253
(760)777-8202
LiC. No.: 684857
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 9/10/12
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
_ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier GRANITE STATE Policy Number WC1914223
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so a to become subject to the workers' compensation laws of California,
and agree that, if I o Id co s 6�ect to the workers' compensation provisions of Section
/ /,{�/I73-700/of the Labor e, ort ith comply with ose provisions.
Date: � ` - Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000)• IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that th a ove i form tion is correct. I agree to comply with all
city and ou tyordinances and state laws relating t b 'din co struct , and hereby author' a representatives
o�this`�'f` un to enter u on the above-mentioned pr rty f r'i cti purposes.
Date: 1 I Signature (Applicant or Agent):
' - s
Application Number . . . . . 12-00000916
Permit
BUILDING PERMIT
Additional
desc . .
Permit Fee
. . . .
284.50
Plan Check Fee
184.93
Issue Date
. . . .
Valuation . . . .
30000
Expiration
Date . .
3/09/13
Qty Unit Charge
Per
Extension
BASE
FEE
252.00
5.00
----------------------------------------------------------------------------
6.5000
THOU BLDG
25,001-50,000
32.50
Permit
. . .
ELECT - ADD/ALT/REM
Additional
desc . .
Permit Fee
. . . .
39.29
Plan Check Fee
9.82
Issue Date
. . . .
Valuation . . . .
0
Expiration
Date . .
3/09/13
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
207.00
.0350
ELEC
NEW RES - 1 OR 2 FAMILY
7.25
177.00
.0200
ELEC
GARAGE OR NON-RESIDENTIAL
3.54
18.00
----------------------------------------------------------------------------
.7500
PER ELEC
DEVICE/FIXTURE 1ST 20
13.50
Permit
. . . MECHANICAL
Additional
desc . .
Permit Fee
. . . .
39.50
Plan Check Fee
9.88
Issue Date
. . . .
Valuation . . . .
0
Expiration
Date . .
3/09/13
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
2.00
4.5000
EA MECH
VENT INST/ DUCT ALT
9.00
1.00
9.0000
EA MECH
APPL REP/ALT/ADD
9.00
1.00
-----------------------=
6.5000
----------------------------------------------------
EA MECH VENT FAN
6.50
Permi t . . . PLUMBING
Additional desc . .
Permit Fee . . . . 45.00
Issue Date . . . .
Expiration Date . . 3/09/13
Plan Check Fee .
Valuation . . .
Qty Unit Charge Per
BASE FEE
4.00 6.0000 EA PLB FIXTURE
1.00 3.0000 EA PLB WATER INST/ALT/REP
LQPERMIT
11.25
0
Extension
15.00
24.00
3.00
Application Number . . . . .
12-00000916
Permit . . . . . . PLUMBING
Qty Unit Charge Per
Extension
1.00 3.0000 EA PLB FIXTURE DRAIN/VENT REP/ALT
3.00
----------------------------------------------------------------------------
Special Notes and Comments
207 SF LIVING ADDITION AND 177
SF CART
GARAGE TO EXISTING DETACHED CASITA PER
ENGINEERED DESIGN. 2010 CODES.
ENGINEER:
DENISE POELTLER C33446
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
BLDG STDS ADMIN (SB1473)
2.00
ENERGY REVIEW FEE
18.49
STRONG MOTION (SMI) - RES
3.00
Fee summary Charged
Paid Credited'
Due
---------------------------
Permit Fee Total 408.29
------------------------------
.00 .00
408.29
Plan Check Total 215.88
.00 .00
215.88
' Other Fee Total 23.49
.00 .00
23.49
Grand Total 647.66
.00 .00
647.66
LQPERMIT
:in # 3A City of La Quinta
Building & Safety Division
Permit # P.O. BOX 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Project Address: %; _r> =` p CC
Owner's Name:
A.P_Number: 76 Z 051 00
Address: •'�;6 —C j � r4fq [
Legal Description IT PG�T
City, ST, Zip: L_,L tki
Contractor: 5�.1
le ltvn
Te p V� Z0�
^'
Address: S/r —T _5 �
Project Description:
City, ST, Zip.
7# IV
Telephone: -7 � 7 ���
77� :;:w::: � � -•
-�-7,�,� `
�
State Lie. # :
City Lie.
G �►d�>1
lot—w—kr., Designer: F
Address: 7 7-672,,:��Krrp--'7 aup
City, ST, Zip: bA � �1
Telephone: 7�`
Construction TYPe: Occu anc
PY:
,
State Lic. #: - `'A'�`Project
Es
a circleone): New Add'n Alter Repair Demo
tyPName
of Contact Person:
Sq. Ft.:
# Stories:#Units:
Telephone # of Contact Person: 60 54b
Estimated Value of Project:
APPLICANT:
DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Rec'd
TRACKING
PERMrr FEES
Plan Sets
Plan Check subnutted---
Item
Amount
Structural Calcs.
a
Reviewed, ready f ections
Plan Check Deposit
Truss Calcs.
tJ
Called Contact Person
Plan Check Balance
Title 24 Calcs.
Plans picked up_
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2°" Review, ready for Correction slue
p
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:
'"' Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
g f 14
. (4
CERTIFICATE OF COMPLIANCEsr„
Desert Sands Unified School District
47950 Dune Palms Road
�O ERMUDADUNESf r
Date
9/10/12
La Quinta, CA 92253
U0 RANCHO MIRAGE
ELLS
31404
(760) 771-8515
DESENo.
�?3 PALM LAQUINTAT�y
INDsa
Owner
Jonathan & Shelly Schenkel
APN #
762-031-004
Address
56965 Merion
Jurisdiction
La Quinta
City
La Quinta Zip
Permit #
Tract #
No. of Units
1
Type
Residential Addition
Lot # No. Street
S.F. Lot # No.
Street
Unit 1
56965 Merion
207 Unit 6
Unit 2
Unit 7
Unit 3
Unit 8
Unit 4
Unit 9
Unit 5
Unit 10
Comments
S.F.
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 207 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Exempt - Bob Edwards Check No.
Name on the check Telephone 760-777-8202
Funding Exempt
By Dr. Sharon P. McGehee
Superintendent
Fee collected /exempted by Shar n McGilvrey Payment Recd $0.00
Over/Under
Signature
NOTICE: Pursuant to Government Code Section 66020(d)(1)�his w/serve to notify you that the 90-day approval period in which you may protest the fees
or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
1J/JU1N/•LU1'l/'1'UE Uy:4� AM Monarch Accounting YAX No• '/6U 776 5112 P. 005
PGA WEST II RESIDENTIAL ASSOCIATION, INC.
39755 BERKEY DRIVE STE A
PALM DESERT, CA 92211
PHONE (760) 776-5100 • FAX (760) 776-5111
June 18, 2012
John & Shelley Schenkel
56-965 Merlon
La Quints, CA 92253
Reference: 56-965 Merion, La Quinta, CA
Architectural Change Request — Casita Enlargement, Golf Cart Garage & Veneer
Dear John & shelly Schenkel:
The Architectural Committee for PGA WEST II Residential Association met on June 141 2012 an&
reviewed and approved your architectural plans and approved with the following conditions being
met.
All other Architectural Rules & Regulations of PGA WEST II Residential Association dated
Revised 8/1/07 pertain.
A Maintenance Agreement will be required, one will be sent to you for proper execution
as soon as it is prepared by counsel.
Your contractor must meet with Bob Pantanella, Director of Community Services prior to
commencing any work so they are aware of access, parking and other regulations of the
Association, Mr. Pantanella's phone numbers is 760-564-1032.
Review by the Committee is onllr far general conformance With a Architectural
Rules. It is the res onsibili of the owner to fully understand and conform to the
Architectural Rules criteria whether or not all deficiencies are noted durinq_review. It
is also the owner's full MWqnsibiliW to field veLA all existintz conditions. The
Committee's decision with regard to project dgsi4n will be final._ Please refer to the
Architectural Rules for all required submittals.
Please contact Luis Umana, Sunshine Landscape at 760/346-3999 and Joanne Rose, the
Association Manager, prior to -any irrigation modifications associated with this change. Damage
to landscaping, i.e. shrubs, trees, flowers and turf is the responsibility of the contractor. The
original landscaping must be brought back to its original condition when the project is completed.
Approvals given by the Architectural Committee are good for only six months from the date
on the approval letter. If construction has not commenced within six months after the project
approval date, a new application must be submitted.
l
I BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Mr. & Mrs. John Schenkle
56-965 Merion
La Quinta, CA 92253
Project Designer:
Robert A. Pitchford Design and Drafting
77-622 Country Club Dr. Suite O
Palm Desert, Ca 92211
(760) 346-2856
Report Prepared by:
Jon Scott
Scott Design and Title 24, Inc,
77-085 Michigan Drive
Palm Desert, Ca 92211
760) 21?-_ 8
TVC
AUG 14 2012
19
BY:--------- OFF ice
Job Number: CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
Date: FOR CONSTRUCnpN
7/31 /2012 [DATEftl t
� -ar��
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC—www.energysoft.com.
5.1 by EneraVSoft User Number: 6712 Run Cade: 2012-07.31T15:15:58 ID:
I TABLE OF CONTENTS I
Cover Page
Table of Contents
2
Cr%rr" f`C_1 D f`cr+ifit+nfc of r mmnlinnr_A j
PERFORMANCE CERTIFICATE: Residential (Part 1 of 5)
CF-1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Mr. &Mrs. John Schenkle
❑ Multi Family m Existing+ Addition/Alteration
2
Project Address
California Energy Climate Zone
Total Cond. Floor Area Additions
Llto(IE
56-965 Merion La Quinta
CA Climate Zone 15
492 207'
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures --
If Yes, A CF-413 must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features --
If Yes, see Part 2 of 5 of this form for details.
INSULATION
Area Special
Construction Type
Cavity (ft) Features (see Part 2 of 5)
Status
Roof Wood Framed Attic
R-19 285
Existing
Wall Wood Framed
None 652
Existing
Slab Unheated Slab -on -Grade
None 285 Perim = 60'
Existing
Roof Wood Framed Attic
R-30 207
New
Wall Wood Framed
R-13 240
New
Wall Wood Framed
R-21 168
New
Slab Unheated Slab -on -Grade
None 207 Perim = 40'
New
FENESTRATION
U-
Exterior
Orientation Area(
Factor
SHGC
Overhang
Sidefins
Shades
Status
Front (S) 4.0
0.800
0.39
none
none
Bug Screen
Existing
Left (lM 4.0
0.690
0.53
none
none
Bug Screen
Existing
Left (1t,) 48.0
0.690
0.53
none
none
Bury Screen
Removed
Front (S) 24.0
0.530
0.46
none
none
Bug Screen
New
Left (W) 48.0
0.530
0.46
none
none
Bug Screen
Existing
HVAC SYSTEMS
Oty. Heating
1 Central Furnace
HVAC DISTRIBUTION
Location Heati
Existing HVAC Ducted
WATER HEATING
Min. Eff Cooling Min. Eff
80% AFUE Split Air Conditioner 10.0 SEER
Cooling Duct Location
Ducted Attic, Ceiling Ins, vented
Gallons Min. Eff Distribution
Thermostat Status
Setback Existing
Duct
R-Value Status
4.2 Existing
Status
5.1 by EnergySoft User Number., 6712 RunCode: 2012-07-31 T15:15:58 ID Page 3 of 10
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R
Project Name Building Type ® Single Family ❑ Addition Alone Date
Mr. & Mrs. John Schenkle ❑ Multi Family m Existing+ Addition/Alteration 713112012
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the Items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the spec lal justification and documentation submitted.
The Existing Wall N Wall Existing has a U-Factor greater than the Vintage Defaults. Field verification is required.
The Existing WaN E Wall Existing has a U Factor greater than the Vintage Qefaults. Field veri cation is required.
The Existing Wall E Wall Removed has a U-Factor greater than the Vintage Defaults. Field verification is required.
The Existing Wall S Wall Existing has a U-Factor greater than the Vintage Defaults. Field verification is required.
The Existing Wall W Wall Existing has a U-Factor greater than the Vintage Defaults. Field verification is required.
Wall W Wall Removed has a U-Factor greater than the Vintage
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-4R form for each of the measures. listed below for final to be iven.
5.1 byEnervvSaR User Number: 6712 Run Code: 2012-07-31T15:15:59 0- Page 4 of
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1R
Project Name Building Type m Single Family 0 Addition Alone I Date
Mr. & Mrs. John Schenkle la Multi Family m Existing+ Addition/Alteration 713112012
ANNUAL ENERGY USE SUMMARY
Standard Proposal Margin
TDV kBtulfer
Space Heating 41.16 35.43 5.73
Space Cooling 314.82 308.70 6.12
Fans 62.20 60.56 1.64
Domestic Hot Water 0.00 0.00 0.00
Pumps 0.00 0.00 0.00
Totals 418.18 404.70 13.48
Percent Better Than Standard: 3.2 %
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (S) 180deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (S) 276 28
Fuel Available at Site: Natural Gas (W 360 52
Raised Floor Area: 0 (N) 288 0
Slab on Grade Area: 492 (E) 216 0
Average Ceiling Height: 12.0 Roof 492 0
Fenestration Average U-Factor: 0.55 TOTAL: 80
Average SHGC: 0.46 Fenestration/CFA Ratio: 16.3
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 5 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Scott Design and Title 24, Inc, 7/31/2012
Address 77-085 Michigan Drive Name Jon Scott
Ci /Statefzi Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date _
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envela sealin require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Robert A. Pitchford Design and Drafting
Address 77-622 Country Club Dr. Suite O Name Robert Pitchford
City/State/Zip Palm Desert, Ca 92211 Phone (760) 346-2856 Signed License # Date
EnerovPro 5.1 by EnerqvSctt User Number: 6712 RunCode: 2012.07-31 T15:15:58 ID: Page 5 of 10
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R
Project Name Building Type ® Single Family ❑ Addition Alone
Date
Mr. & Mrs. John Schenkle ❑ Multi Family m Existing+ Addition/Alteration
713112012
OPAQUE SURFACE DETAILS
Surface
U-
Insulation
Joint Appendix
Area
Factor
Azm
Tilt
Status
4
Location/Comments
(favIty
Exterior
Frame
Interior
Frame
—Type
Roof
285
0.049
R-19
0
20
Existin
4.2.1-A4
Existing Casita
Wall
192
0.356
None
0
90
Existin
4.3.1-A1
Existing Casita
Wall
72
0.356
None
90
90
Existing4.3.1-A1
Existln Casita
wali
144
0.356
None
90
90
Remove
4.3.1-A1
Existing Casita
Wall
17d
0.356
None
180
901
Existing
4.3.1-A1
Existing Casita
VYali
68
0.356
None
270
901
Existing
4.3.1 Al
Existing Casita
Wall
144
0.356
None
270
901
Existing
4.3.1-A1
Existin2 Casita
Slab
285
0.730
None
0
180
Existing
4.4.7-A1
Existing Casita
Roof
207
0.031
R-30
0
0
New
4.2.1-A20
Addition
Wall
96
0.102
R-13
0
90
New
•4.3.1-A3
Addilion
Wall
144
0.102
R-13
90
90
New
4.3.1-A3
Addition
Wall
72
0.069
R-21
IN
1801
90
New
4.3.1-A6
Addition
wall
96
0.069
R-21
1
1 2701
90
New
4.3.1-A6
Addition
Slab
1 207
0.730
None
01
180
New
4.4.7-A1
Addition
FENESTRATION SURFACE DETAILS
ID
T e
Area
U-Factor`
SHGC`
l
Window
4.0
0.800
NFRC
0.39
NFRC
2
Window
4.0
0.690
NFRC
0.53
NFRC
3
Window
48.0
0.690
NFRC
0.53
NFRC
4
Window
24.0
0.530
NFRC
0.46
NFRC
5
Wndow
48.0
0.530
NFRC
0.46
NFRC
(1) U-Factor Type: 116-A = Default Table from
(2) SHGC Type: 116-B = Default Table from
EXTERIOR SHADING DETAILS
Ill I
Exterior Shade Type
SHGC
1
jBug Screen
0. 7E
2
Eug Screen
0.7E
3 1Bug
Screen
0.7E
4
Bug Screen
0.7E
5
Bua Screen
0.7E
Status I Glazing T.
180
Existing
Glass Block
270
ExistinT
Dual Metal Tint ex
270
Removed
Dual Metal Tint ex
180
New
Dual Metal Tint
270
Existing
Dual Metal Tint
NFRC = Labeled Value
NFRC = Labeled Value
LocatiorVComments
Existing Casita
Existing Casita
Existing Casita
Addition
Addition
5.1 by EnergySaR user Number.' 6712
CERTIFICATE OF COMPLIANCE:
Residential
(Part 5 of 5)
CF-1 R
Project Name
Building Type ® Single Family
❑ Addition Alone
Date
Mr. & Mrs. John Schenkle
❑ Multi Family
m Existing+ Addition/Alteration
7/31/2012
I RI III nihir. 7nNF INFCIRMATION
Existing HVAC
HVAC SYSTEMS
System Name . Heating T e
Qt
Min. Eff. Cooll Type Min. Eff. Thermostat T e
Status
Existing HVAC 1 Central Furnace
80% AFUE Split Air Conditioner 10.0 SEER Setback
Existing
HVAC DISTRIBUTION
Duct
Ducts
System Name Heating__Cooling
Duct Location R-Value
Tested?
Status
Exlsting HVAC Ducted
Ducted Aftic, Ceiling Ins. vented 4.2
❑
Existing
-4
Ei
WATER HEATING SYSTEMS
Ext.
Rated Tank Energy Standby
Tank
Input Cap. Factor Loss or
Insul. R-
S stem Name Qty. T e
Distribution Btuh al) or RE Pilot
Value
Status
CEC Standard
MULTI -FAMILY WATER HEATING DETAILS
HYDRONIC HEATING SYSTEM PIPING
Hot Water Piping Length
(ft) o
i�
U) Pipe
Pipe
Insul.
Control Qty. HP Plenum
Outside Buried a System Name Len th
Diameter Thick.
Eno Pro5.lbyEnergySqft User Number: 6712
Run Cade: 2012-07--31 T15:15:58 ID:
Page 7 of 10
MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3) MF-1 R
Project Name Date
Mr. & Mrs. John Schenkle 713112012
(VOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF-
1 R-ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R
Form with plans.
I Buildinq Envelope Measures:
116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain
Coefficient (SH(3C), and infiltration that meets the requirements of 10-111 (a).
5117: Exterior doors and windows are weather-stripped: all joints and penetrations are caulked and sealed.
118 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF-1 R Form.
' 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent 1-1-factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-Value.
150 c : Minimum R-13 insulation in wood -frame wall orequivalent 1-1-factor.
150[d]: Minimum R-13 insulation in raised woad -frame floor orequivalent U-factor.
150 f : Air retardin wra is tested, labeled, and installed accordin to ASTM E1677-95 2000 when s ecified on the CF-1 R Form.
150 : Mandator Va or barrier installed in Climate Zones 14 or 16.
§150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no rester than 2.0 0 mlinch and shad be rotected from h sical dams e and UV li ht deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1A. Mason ry or factor -built fire laces have a closable metal or lass door coverinq the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches In area and is
e ui ed with a with a readil accessible, ❑ erable, and ti ht fittin damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air far cooling a firebox jacket, when that indoor air is vented to the
outside of the buildin , are rohibited.
Space Conditioning, Water Keating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
and/or cooling loads are calculated in accordance with ASH RAE, SMACNA or ACCA.
150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculatingsections of hot water pipes are insulated per Standards Table 150-B.
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance and wind.
§150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
Solar water -heating systems and/or collectors are certified by the
and Certification
EneravPro 5.1 bvEnergySoft User Number. 6712 RunCode: 2012-07-31T15:15:58 ID: Page 8 of 10
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R
Project Name Date
Mr. & Mrs. John Schenkle 713112012
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such toe is used in combination with mastic and draw bands.
150 m 7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating or a pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the Eump sizing, flow rate, piping, filters, and valve requirements of 150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §430(d).
§ 150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§f 50(k)5: Permanently installed night lights and night lights integral to a permanently Installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150 k 6: Lighting Integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of 150k .
150 k 7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by Enargy5of[ User Number. 6712 RunCode: 2012-07-31T15:15:58 ID: Page 9 of 10
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R
Project Name Date
Mr. & Mrs. John Schenkle 1 713112012
§150(k)10: Permanently installed luminaires in bathrooms, attached and delached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy lulmnaires. EXCEPTION 1. Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to cam I with §150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exception) to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134. and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2012-07-31T15:15:58 ID: Page 10 of 10