Loading...
12-0916 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 12=.00000916 Property Address: --56965 MERION APN: 762 -031 -004 - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 30000 Tu!t�440" Applicant: Architect or Engineer: N - BUILDING & SAFETY DEPARTMENT BUILDING PERMIT LICENSED CONTRACTOR'S DECLARATION I hereby affir under penalty of per' h I a 'tensed under provisions of Chapter 9 (commencing with Section 0 1 of Division 3 of the usi e s 2 rof ssionals Co e, and my License is in full force and effect. License I B C2�7 _ Lice a No.: 684857 --'--Date: ✓Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500): (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.l. (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. B.&P.C. for this reason /-Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Owner: SCHENKEL, JONATHAN & SHELLY 1904 BROWNING WAY SANDPOINT, ID 83864 Contractor: EDWARDS CONSTRUCTION INC, BOB 51455 DESERT CLUB DRIVE LA QUINTA, CA 92253 (760)777-8202 LiC. No.: 684857 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/10/12 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier GRANITE STATE Policy Number WC1914223 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so a to become subject to the workers' compensation laws of California, and agree that, if I o Id co s 6�ect to the workers' compensation provisions of Section / /,{�/I73-700/of the Labor e, ort ith comply with ose provisions. Date: � ` - Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000)• IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that th a ove i form tion is correct. I agree to comply with all city and ou tyordinances and state laws relating t b 'din co struct , and hereby author' a representatives o�this`�'f` un to enter u on the above-mentioned pr rty f r'i cti purposes. Date: 1 I Signature (Applicant or Agent): ' - s Application Number . . . . . 12-00000916 Permit BUILDING PERMIT Additional desc . . Permit Fee . . . . 284.50 Plan Check Fee 184.93 Issue Date . . . . Valuation . . . . 30000 Expiration Date . . 3/09/13 Qty Unit Charge Per Extension BASE FEE 252.00 5.00 ---------------------------------------------------------------------------- 6.5000 THOU BLDG 25,001-50,000 32.50 Permit . . . ELECT - ADD/ALT/REM Additional desc . . Permit Fee . . . . 39.29 Plan Check Fee 9.82 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/09/13 Qty Unit Charge Per Extension BASE FEE 15.00 207.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 7.25 177.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 3.54 18.00 ---------------------------------------------------------------------------- .7500 PER ELEC DEVICE/FIXTURE 1ST 20 13.50 Permit . . . MECHANICAL Additional desc . . Permit Fee . . . . 39.50 Plan Check Fee 9.88 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/09/13 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 4.5000 EA MECH VENT INST/ DUCT ALT 9.00 1.00 9.0000 EA MECH APPL REP/ALT/ADD 9.00 1.00 -----------------------= 6.5000 ---------------------------------------------------- EA MECH VENT FAN 6.50 Permi t . . . PLUMBING Additional desc . . Permit Fee . . . . 45.00 Issue Date . . . . Expiration Date . . 3/09/13 Plan Check Fee . Valuation . . . Qty Unit Charge Per BASE FEE 4.00 6.0000 EA PLB FIXTURE 1.00 3.0000 EA PLB WATER INST/ALT/REP LQPERMIT 11.25 0 Extension 15.00 24.00 3.00 Application Number . . . . . 12-00000916 Permit . . . . . . PLUMBING Qty Unit Charge Per Extension 1.00 3.0000 EA PLB FIXTURE DRAIN/VENT REP/ALT 3.00 ---------------------------------------------------------------------------- Special Notes and Comments 207 SF LIVING ADDITION AND 177 SF CART GARAGE TO EXISTING DETACHED CASITA PER ENGINEERED DESIGN. 2010 CODES. ENGINEER: DENISE POELTLER C33446 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 2.00 ENERGY REVIEW FEE 18.49 STRONG MOTION (SMI) - RES 3.00 Fee summary Charged Paid Credited' Due --------------------------- Permit Fee Total 408.29 ------------------------------ .00 .00 408.29 Plan Check Total 215.88 .00 .00 215.88 ' Other Fee Total 23.49 .00 .00 23.49 Grand Total 647.66 .00 .00 647.66 LQPERMIT :in # 3A City of La Quinta Building & Safety Division Permit # P.O. BOX 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Project Address: %; _r> =` p CC Owner's Name: A.P_Number: 76 Z 051 00 Address: •'�;6 —C j � r4fq [ Legal Description IT PG�T City, ST, Zip: L_,L tki Contractor: 5�.1 le ltvn Te p V� Z0� ^' Address: S/r —T _5 � Project Description: City, ST, Zip. 7# IV Telephone: -7 � 7 ��� 7­7� :;:w::: � � -• -�-7,�,� ` � State Lie. # : City Lie. G �►d�>1 lot—w—kr., Designer: F Address: 7 7-672,,:��Krrp--'7 aup City, ST, Zip: bA � �1 Telephone: 7�` Construction TYPe: Occu anc PY: , State Lic. #: - `'A'�`Project Es a circleone): New Add'n Alter Repair Demo tyPName of Contact Person: Sq. Ft.: # Stories:#Units: Telephone # of Contact Person: 60 54b Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERMrr FEES Plan Sets Plan Check subnutted--- Item Amount Structural Calcs. a Reviewed, ready f ections Plan Check Deposit Truss Calcs. tJ Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up_ Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2°" Review, ready for Correction slue p Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE: '"' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees g f 14 . (4 CERTIFICATE OF COMPLIANCEsr„ Desert Sands Unified School District 47950 Dune Palms Road �O ERMUDADUNESf r Date 9/10/12 La Quinta, CA 92253 U0 RANCHO MIRAGE ELLS 31404 (760) 771-8515 DESENo. �?3 PALM LAQUINTAT�y INDsa Owner Jonathan & Shelly Schenkel APN # 762-031-004 Address 56965 Merion Jurisdiction La Quinta City La Quinta Zip Permit # Tract # No. of Units 1 Type Residential Addition Lot # No. Street S.F. Lot # No. Street Unit 1 56965 Merion 207 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments S.F. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 207 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Bob Edwards Check No. Name on the check Telephone 760-777-8202 Funding Exempt By Dr. Sharon P. McGehee Superintendent Fee collected /exempted by Shar n McGilvrey Payment Recd $0.00 Over/Under Signature NOTICE: Pursuant to Government Code Section 66020(d)(1)�his w/serve to notify you that the 90-day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting 1J/JU1N/•LU1'l/'1'UE Uy:4� AM Monarch Accounting YAX No• '/6U 776 5112 P. 005 PGA WEST II RESIDENTIAL ASSOCIATION, INC. 39755 BERKEY DRIVE STE A PALM DESERT, CA 92211 PHONE (760) 776-5100 • FAX (760) 776-5111 June 18, 2012 John & Shelley Schenkel 56-965 Merlon La Quints, CA 92253 Reference: 56-965 Merion, La Quinta, CA Architectural Change Request — Casita Enlargement, Golf Cart Garage & Veneer Dear John & shelly Schenkel: The Architectural Committee for PGA WEST II Residential Association met on June 141 2012 an& reviewed and approved your architectural plans and approved with the following conditions being met. All other Architectural Rules & Regulations of PGA WEST II Residential Association dated Revised 8/1/07 pertain. A Maintenance Agreement will be required, one will be sent to you for proper execution as soon as it is prepared by counsel. Your contractor must meet with Bob Pantanella, Director of Community Services prior to commencing any work so they are aware of access, parking and other regulations of the Association, Mr. Pantanella's phone numbers is 760-564-1032. Review by the Committee is onllr far general conformance With a Architectural Rules. It is the res onsibili of the owner to fully understand and conform to the Architectural Rules criteria whether or not all deficiencies are noted durinq_review. It is also the owner's full MWqnsibiliW to field veLA all existintz conditions. The Committee's decision with regard to project dgsi4n will be final._ Please refer to the Architectural Rules for all required submittals. Please contact Luis Umana, Sunshine Landscape at 760/346-3999 and Joanne Rose, the Association Manager, prior to -any irrigation modifications associated with this change. Damage to landscaping, i.e. shrubs, trees, flowers and turf is the responsibility of the contractor. The original landscaping must be brought back to its original condition when the project is completed. Approvals given by the Architectural Committee are good for only six months from the date on the approval letter. If construction has not commenced within six months after the project approval date, a new application must be submitted. l I BUILDING ENERGY ANALYSIS REPORT PROJECT: Mr. & Mrs. John Schenkle 56-965 Merion La Quinta, CA 92253 Project Designer: Robert A. Pitchford Design and Drafting 77-622 Country Club Dr. Suite O Palm Desert, Ca 92211 (760) 346-2856 Report Prepared by: Jon Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 760) 21?-_ 8 TVC AUG 14 2012 19 BY:--------- OFF ice Job Number: CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED Date: FOR CONSTRUCnpN 7/31 /2012 [DATEftl t � -ar�� The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC—www.energysoft.com. 5.1 by EneraVSoft User Number: 6712 Run Cade: 2012-07.31T15:15:58 ID: I TABLE OF CONTENTS I Cover Page Table of Contents 2 Cr%rr" f`C_1 D f`cr+ifit+nfc of r mmnlinnr_A j PERFORMANCE CERTIFICATE: Residential (Part 1 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Mr. &Mrs. John Schenkle ❑ Multi Family m Existing+ Addition/Alteration 2 Project Address California Energy Climate Zone Total Cond. Floor Area Additions Llto(IE 56-965 Merion La Quinta CA Climate Zone 15 492 207' FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-413 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features (see Part 2 of 5) Status Roof Wood Framed Attic R-19 285 Existing Wall Wood Framed None 652 Existing Slab Unheated Slab -on -Grade None 285 Perim = 60' Existing Roof Wood Framed Attic R-30 207 New Wall Wood Framed R-13 240 New Wall Wood Framed R-21 168 New Slab Unheated Slab -on -Grade None 207 Perim = 40' New FENESTRATION U- Exterior Orientation Area( Factor SHGC Overhang Sidefins Shades Status Front (S) 4.0 0.800 0.39 none none Bug Screen Existing Left (lM 4.0 0.690 0.53 none none Bug Screen Existing Left (1t,) 48.0 0.690 0.53 none none Bury Screen Removed Front (S) 24.0 0.530 0.46 none none Bug Screen New Left (W) 48.0 0.530 0.46 none none Bug Screen Existing HVAC SYSTEMS Oty. Heating 1 Central Furnace HVAC DISTRIBUTION Location Heati Existing HVAC Ducted WATER HEATING Min. Eff Cooling Min. Eff 80% AFUE Split Air Conditioner 10.0 SEER Cooling Duct Location Ducted Attic, Ceiling Ins, vented Gallons Min. Eff Distribution Thermostat Status Setback Existing Duct R-Value Status 4.2 Existing Status 5.1 by EnergySoft User Number., 6712 RunCode: 2012-07-31 T15:15:58 ID Page 3 of 10 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name Building Type ® Single Family ❑ Addition Alone Date Mr. & Mrs. John Schenkle ❑ Multi Family m Existing+ Addition/Alteration 713112012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the Items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the spec lal justification and documentation submitted. The Existing Wall N Wall Existing has a U-Factor greater than the Vintage Defaults. Field verification is required. The Existing WaN E Wall Existing has a U Factor greater than the Vintage Qefaults. Field veri cation is required. The Existing Wall E Wall Removed has a U-Factor greater than the Vintage Defaults. Field verification is required. The Existing Wall S Wall Existing has a U-Factor greater than the Vintage Defaults. Field verification is required. The Existing Wall W Wall Existing has a U-Factor greater than the Vintage Defaults. Field verification is required. Wall W Wall Removed has a U-Factor greater than the Vintage HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures. listed below for final to be iven. 5.1 byEnervvSaR User Number: 6712 Run Code: 2012-07-31T15:15:59 0- Page 4 of PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1R Project Name Building Type m Single Family 0 Addition Alone I Date Mr. & Mrs. John Schenkle la Multi Family m Existing+ Addition/Alteration 713112012 ANNUAL ENERGY USE SUMMARY Standard Proposal Margin TDV kBtulfer Space Heating 41.16 35.43 5.73 Space Cooling 314.82 308.70 6.12 Fans 62.20 60.56 1.64 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 418.18 404.70 13.48 Percent Better Than Standard: 3.2 % BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (S) 180deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 276 28 Fuel Available at Site: Natural Gas (W 360 52 Raised Floor Area: 0 (N) 288 0 Slab on Grade Area: 492 (E) 216 0 Average Ceiling Height: 12.0 Roof 492 0 Fenestration Average U-Factor: 0.55 TOTAL: 80 Average SHGC: 0.46 Fenestration/CFA Ratio: 16.3 REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 5 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 7/31/2012 Address 77-085 Michigan Drive Name Jon Scott Ci /Statefzi Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date _ The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envela sealin require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Robert A. Pitchford Design and Drafting Address 77-622 Country Club Dr. Suite O Name Robert Pitchford City/State/Zip Palm Desert, Ca 92211 Phone (760) 346-2856 Signed License # Date EnerovPro 5.1 by EnerqvSctt User Number: 6712 RunCode: 2012.07-31 T15:15:58 ID: Page 5 of 10 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Building Type ® Single Family ❑ Addition Alone Date Mr. & Mrs. John Schenkle ❑ Multi Family m Existing+ Addition/Alteration 713112012 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Area Factor Azm Tilt Status 4 Location/Comments (favIty Exterior Frame Interior Frame —Type Roof 285 0.049 R-19 0 20 Existin 4.2.1-A4 Existing Casita Wall 192 0.356 None 0 90 Existin 4.3.1-A1 Existing Casita Wall 72 0.356 None 90 90 Existing4.3.1-A1 Existln Casita wali 144 0.356 None 90 90 Remove 4.3.1-A1 Existing Casita Wall 17d 0.356 None 180 901 Existing 4.3.1-A1 Existing Casita VYali 68 0.356 None 270 901 Existing 4.3.1 Al Existing Casita Wall 144 0.356 None 270 901 Existing 4.3.1-A1 Existin2 Casita Slab 285 0.730 None 0 180 Existing 4.4.7-A1 Existing Casita Roof 207 0.031 R-30 0 0 New 4.2.1-A20 Addition Wall 96 0.102 R-13 0 90 New •4.3.1-A3 Addilion Wall 144 0.102 R-13 90 90 New 4.3.1-A3 Addition Wall 72 0.069 R-21 IN 1801 90 New 4.3.1-A6 Addition wall 96 0.069 R-21 1 1 2701 90 New 4.3.1-A6 Addition Slab 1 207 0.730 None 01 180 New 4.4.7-A1 Addition FENESTRATION SURFACE DETAILS ID T e Area U-Factor` SHGC` l Window 4.0 0.800 NFRC 0.39 NFRC 2 Window 4.0 0.690 NFRC 0.53 NFRC 3 Window 48.0 0.690 NFRC 0.53 NFRC 4 Window 24.0 0.530 NFRC 0.46 NFRC 5 Wndow 48.0 0.530 NFRC 0.46 NFRC (1) U-Factor Type: 116-A = Default Table from (2) SHGC Type: 116-B = Default Table from EXTERIOR SHADING DETAILS Ill I Exterior Shade Type SHGC 1 jBug Screen 0. 7E 2 Eug Screen 0.7E 3 1Bug Screen 0.7E 4 Bug Screen 0.7E 5 Bua Screen 0.7E Status I Glazing T. 180 Existing Glass Block 270 ExistinT Dual Metal Tint ex 270 Removed Dual Metal Tint ex 180 New Dual Metal Tint 270 Existing Dual Metal Tint NFRC = Labeled Value NFRC = Labeled Value LocatiorVComments Existing Casita Existing Casita Existing Casita Addition Addition 5.1 by EnergySaR user Number.' 6712 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name Building Type ® Single Family ❑ Addition Alone Date Mr. & Mrs. John Schenkle ❑ Multi Family m Existing+ Addition/Alteration 7/31/2012 I RI III nihir. 7nNF INFCIRMATION Existing HVAC HVAC SYSTEMS System Name . Heating T e Qt Min. Eff. Cooll Type Min. Eff. Thermostat T e Status Existing HVAC 1 Central Furnace 80% AFUE Split Air Conditioner 10.0 SEER Setback Existing HVAC DISTRIBUTION Duct Ducts System Name Heating__Cooling Duct Location R-Value Tested? Status Exlsting HVAC Ducted Ducted Aftic, Ceiling Ins. vented 4.2 ❑ Existing -4 Ei WATER HEATING SYSTEMS Ext. Rated Tank Energy Standby Tank Input Cap. Factor Loss or Insul. R- S stem Name Qty. T e Distribution Btuh al) or RE Pilot Value Status CEC Standard MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Hot Water Piping Length (ft) o i� U) Pipe Pipe Insul. Control Qty. HP Plenum Outside Buried a System Name Len th Diameter Thick. Eno Pro5.lbyEnergySqft User Number: 6712 Run Cade: 2012-07--31 T15:15:58 ID: Page 7 of 10 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3) MF-1 R Project Name Date Mr. & Mrs. John Schenkle 713112012 (VOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. I Buildinq Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient (SH(3C), and infiltration that meets the requirements of 10-111 (a). 5117: Exterior doors and windows are weather-stripped: all joints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. ' 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent 1-1-factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. 150 c : Minimum R-13 insulation in wood -frame wall orequivalent 1-1-factor. 150[d]: Minimum R-13 insulation in raised woad -frame floor orequivalent U-factor. 150 f : Air retardin wra is tested, labeled, and installed accordin to ASTM E1677-95 2000 when s ecified on the CF-1 R Form. 150 : Mandator Va or barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no rester than 2.0 0 mlinch and shad be rotected from h sical dams e and UV li ht deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1A. Mason ry or factor -built fire laces have a closable metal or lass door coverinq the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches In area and is e ui ed with a with a readil accessible, ❑ erable, and ti ht fittin damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air far cooling a firebox jacket, when that indoor air is vented to the outside of the buildin , are rohibited. Space Conditioning, Water Keating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and and/or cooling loads are calculated in accordance with ASH RAE, SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatingsections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. Solar water -heating systems and/or collectors are certified by the and Certification EneravPro 5.1 bvEnergySoft User Number. 6712 RunCode: 2012-07-31T15:15:58 ID: Page 8 of 10 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date Mr. & Mrs. John Schenkle 713112012 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such toe is used in combination with mastic and draw bands. 150 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the Eump sizing, flow rate, piping, filters, and valve requirements of 150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §430(d). § 150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §f 50(k)5: Permanently installed night lights and night lights integral to a permanently Installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Lighting Integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of 150k . 150 k 7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by Enargy5of[ User Number. 6712 RunCode: 2012-07-31T15:15:58 ID: Page 9 of 10 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date Mr. & Mrs. John Schenkle 1 713112012 §150(k)10: Permanently installed luminaires in bathrooms, attached and delached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy lulmnaires. EXCEPTION 1. Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to cam I with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exception) to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134. and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2012-07-31T15:15:58 ID: Page 10 of 10