AR (06-2971)P.O. BOX 1504 VOICE (760) 777-7012
78-495.CALLE TAMPICO FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 9/22/06
Application Number: 06-00002971 Owner:
Property Address: 57181 MERION .l ARCH MONTGOMERY
APN: 762-031-012- - - 57181 MERION
Application description: ADDITION - RESIDENTIAL LA QUINTA, CA 92253
17 -Property Zoning: LOW DENSITY RESIDENTIAL, '
Application valuation: 30000
Applicant:
Architect or Engineer:
--------------------------------------------------
LICENSED CONTRACTOR'S DECLARATION '
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
'Section 7000) of Division 3 of the Business and Professi naIs Code, and my License is in full force and effect.
License Class: 13/ License No.: 541716
Date: l(� `2L -0(P Contractor: -
OWNER -BUILDER DECLARATION - -
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the .
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty. of not more than five hundred dollars 1$5001.:
(_ 1 I, as owner 6f the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the -building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
( ) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERIMIT
Contractor: o U
PC CONSTRUCTION
49950 JEFFERSON #130-331
INDIO, CA 92202 SEP 22 2006
(760)771-6332
Lic . No.: 541716 CITY OF LA QUINTA
----------------------------------------------—
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and'will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of -the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
' insurance carrier and policy number are:
Carrier STATE FUND Policy Number 0036806-2006
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
��/) //��3770�0 of the Labor C(o////ddde�IS/,hall ff it comply with those provisions.
Date: -2 _`-'y Applicant: �../ / �(� YJ '
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation. '
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construct" o and hereby authorize representatives
of this county to enter upon the above-mentioned property " r i pectio urp g__ _
late Signature (Applicant or Agent): F
LQPERMIT -
Application Number .
. . . . 06-00002971
Permit . . . . .
BUILDING PERMIT
Additional desc .
Permit Fee . . . .
284.50 Plan Check Fee
184.93
Issue Date . . . .
Valuation
30000
Expiration Date ...
3/21/07
Qty Unit Charge
Per
Extension
BASE FEE
252.00
5.00 6.5000
THOU BLDG 25,001-50,000
32.50
Permit
ELECT - ADD/ALT/REM
Additional desc .
Permit Fee . . . .
36.41 Plan Check Fee
9.10
_
Issue•Date
Valuation
0
Expiration Date
3/21/07
Qty Unit Charge
Per
Extension
BASE FEE
15.00
183.00 .0350
ELEC NEW RES - 1 OR 2 FAMILY
6.41
20.00 .7500
-----------------------------------------------------------------------------
PER ELEC DEVICE/FIXTURE 1ST.20
15.00
Permit . . .
MECHANICAL
Additional desc .
Permit Fee . . . .
19.50 Plan Check Fee ..
4.88
Issue Date . . .
Valuation . . . .
0
Expiration Date
3/21/07
Qty Unit Charge
.Per
Extension
BASE .FEE
15.00
1.00 4.5000
-----------------------------------
EA MECH VENT INST/ DUCT ALT
-----------------------------------------
4.50
Permit . . .
PLUMBING
Additional desc .
Permit Fee
39.00 Plan Check Fee
9.75
Issue Date . . . .
Valuation
0
Expiration Date
3/21/07
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1.00 6.0000
EA PLB FIXTURE
6.00
1.00 15.0000
EA PLB BUILDING SEWER
15.00
1.00 3'.0000
EA PLB WATER INST/ALT/REP
----------------------------
3.00
--------------------------------------------
Special'Notes and Comments
183 SQ FT ADDITION WITH
REMODEL TO
LQPERMIT -
Application.Number . . . . .
06-00002971
Special Notes and Comments
EXISTING CASITA• September 20,
2006
4:59:20 PM AORTEGA
----------------------------------------------------------------------------
- Other Fees . . . . . . . .
ENERGY REVIEW
FEE
18.49
STRONG MOTION
(SMI) - RES
3.00
Fee summary Charged
Paid Credited
Due
Permit Fee Total 379.41
00
00
379.41
Plan Check Total 208.6.6
.00
.00
208.66
Other Fee Total 21.49
.00
.00
21.49,
Grand Total 609.56
.00
.00
609.56
i
LQPERMIT
-
}" '�^�'' '�'\ `i~ �:�. •�� � � -,. - �� ••� -ter,; !ice ��tY.�'1 ^� .
win:
f
y
City ofla' Quinta
Building 8I Safety. Division .
P.O. Box 1504, 78-495 Calle Tampicot
La
Quinta,CA 92253 - 760 777-7012 Building PermitApplication and Tracking Sheet rY ;
D�
Project Address: �7 7 -1&
99
Owner's Name: ?e_ (+ )-koOT&c Ker.
A. P. Number: 4O Z t
Address: X71 8 K,%-,rWJ.5 . '
Legal Description:City,
Contractor: -Fc-
ST, Zip: („� Ql�l0 A ���-.gzz5zx
Telephone:, 7100"• 564 "up (I ;WNY °. }
- QS ^n��ro S I
Address: O -'C %)
Project Description:
4"t
City, ST, Zip: (h Dl 0 C-Ct, : l ?��D Z �j , .(�10�7
i't'O CYC (Sri �J
Telephone: t t -L
� ��� _
x�
City Lic. #:
t�+1^f'7l C -r . �'V--���1D
�
State Lie. # :14 1 40
Arch., Engr., Designer: �.�• �l$ Ot l��t�leS
• i
Address: QjTj-rj'Z(j �V���. tl� W4
City, ST, Zip: 7:V_1tiQ1 O Cq Q 2ZO.i
Telephone:
r�
`
Construction Type: Occupancy:
State Lic. #: l
Project type (circle one): New Add'n "Alter -Repair Demo
Sq. Ft.: # Stories: # Units:
Name of Contact Person: tt1F�� �8a tU
Telephone # of Contact Person: _24,0- V741 -. c7ljQq)�.
Estimated Value'of Project:
APPLICANT: DO NOT WRITE.BELOW/TAIS LINE �.
#
Submittal Req'd
Rec'd
r' .�'� U TRACKING. j
PERMIT FEES
Plan Sets
a
Plan Check submitted • – o
�� �Y
Item
Amount
Reviewed, ready for corrections
��
Plan Check Deposit
Truss Calcs.
Called Contact Person
Plan Check Balance
Energy Caics.
Plans picked up 1
Construction
Flood plain plan
Plans resubmitted .
Mechanical - •
Grading plan
2,d Review, ready for correctio fissue
11to
.Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
M.O.A. Approval
Plans resubmitted
Grading
.IN HOUSE:-
'`d Review, ready for corrections/issue
Developer Impact Feed
Planning Approval
Called Contact Person
A.LP.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Q
Total Permit'Fees
18125- T1s R=L (N),: q P�
57, APP
1-a�
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5
00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho
mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq. '
in the amount of $0.00 X 183 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Exempt - Frank Moreno
Name on the check
By Dr. Doris Wilson
Superintendent
Check No.
Telephone 772.2255
Funding Exempt
Al;4
Fee collected /exemp d by ar n i Vrey Payment Recd X0.00
a,tin
&ver/Under��
Signature
NOTICE: Pursuant to Government Code Section 66020(d)(1), t ' serve to notify you that the 90 -day approval period MI. hidi'you'may Protest the fees o
r other payment identified above will begin to run from the date on which the building or installation permit for this project is is '"OW from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them'on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
��►Al°
47950 Dune Palms Road
¢ BERMUDA DUNES O
Date
9/21/06
_
La Quinta, CA 92253
V .RANCHO MIRAGE'' o
IN DIAN WELLS
No.
28915
(760) 771-8515
a' P IA °u'" A �y
�INDIO y�
y
0 .
Owner
'
Arch Montgomery
APN #
762-031-012
Address
57-181 Merion
Jurisdiction
La Quinta
City
La Quinta Zip 92253
Permit #
Tract #
Study Area
Type
Residential Addition
No. of Units
1
Lot # No. Street
S.F. Lot # No.
Street S.F.
Unit 1
57181 Merion
183 Unit 6
Unit 2
Unit 7
Unit 3
Unit 8
-.
Unit 4
Unit 9
Unit 5
Unit 10
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5
00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho
mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq. '
in the amount of $0.00 X 183 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Exempt - Frank Moreno
Name on the check
By Dr. Doris Wilson
Superintendent
Check No.
Telephone 772.2255
Funding Exempt
Al;4
Fee collected /exemp d by ar n i Vrey Payment Recd X0.00
a,tin
&ver/Under��
Signature
NOTICE: Pursuant to Government Code Section 66020(d)(1), t ' serve to notify you that the 90 -day approval period MI. hidi'you'may Protest the fees o
r other payment identified above will begin to run from the date on which the building or installation permit for this project is is '"OW from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them'on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting
TITLE 24 REPORT
Title 24 Report for:
Arch Montgomery Res.
57-181 Merion St.
La Quinta, CA 92253
Project Designer:
Frank A. Moreno
79-943 Memorial PI
La Quinta, CA 92253
760-899-5992 '
Report Prepared By:
Frank A. Moreno J
Power Brokers
51370 Avenida Bermudas Suite 1
La Quinta, CA 92253
(760) 564-8470
6FYIl�
CITY OF LA QUINTA Job Number:
BUILDING & SAFETY DEPT. Master Set Q [�
APPROVED
FOR CONSTRUCTION $EP 0 7 2006
Date: `
DA ?d ?obJo gy�, B
Y
9/6/2006
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.2 by EnergySoft Job Number. Master Set User Number. 6115
TABLE OF CONTENTS
Cover Page
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Summary 7
HVAC System Heating and Cooling Loads Summary 9
Room Load Summary 110
EnergyPro 4.2 by EnergySoft Job Numbed Master Set User Number. 6115
Certificate Of Compliance: Residential (Part 1 of 4) CF -1 R
Arch Montgomery Res_
467
ft2
9/6/2006
Project Title
ft2
Raised Floor Area:
Date
57-181 Medan St I a-Qlanta
Slab on Grade Area:
467
ft2
Average Ceiling Height:
Project Address
ft
Number of Dwelling Units:
1.00
Building Permit #
pOLYer_BT- kers
1
(760) 564-8470
Documeenta�tion Author
Telephone
Plan Check/Date
Cm Iplffdce impMethod
Climate Zone 15
Field Check/Date
TDV
Standard
Proposed
Compliance
kBtu/sf-yr)
Design
Design
Margin
Space Heating
1.27
0.09
1.18
Space Cooling
77.41
61.78
15.63
Fans
11.73
11.46
0.27
Domestic Hot Water
33.42
18.50
14.92
Pumps
0.00
0.00
0.00
Totals
123.83
91.84
31.99
Building Type: Y Single Family
❑ Multi Family
Building Front Orientation:
Fuel Type:
Fenestration:
❑ Addition
❑ Existing + Add/Alt
(N) 0 deg
Natural Gas
Area: . 69 ft 2 Avg. U: 0.87
Ratio: 14.8% Avg. SHGC: 0.70
Total Conditioned Floor Area:
467
ft2
Existing Floor Area:
n/a
ft2
Raised Floor Area:
0
ft2
Slab on Grade Area:
467
ft2
Average Ceiling Height:
9.0
ft
Number of Dwelling Units:
1.00
Number of Stories:
1
BUILDING ZONE INFORMATION # of Thermostat Vent
Zone Name Floor Area Volume Units Zone Type Type Hgt. Area
Res HVAC 46 a 203 100 Conditioned No Swthack _2 iia
OPAQUE SURFACES Insulation Act.
Type Frame Area U -Fac. Cay. Cont. Azm. Tilt
Boot— Wood_ x.67- _0051 R-19 _R=0.0_ 0_ 92
Wall 115 0.074 R_19 R 0.0 270 _9
Wall Wood 223_ . .074 R_19 R-0-0 Q gQ
Wall Wood— x.64- 0074 R-19 R-0 0-90_ 90
Wall Wood_ 243_ 0.074 R_19 R-0.0 270 _9.n
Gains Condition
Y / N Status JA IV Reference Location / Comments
New 02-A5 1 st Floor 7one
New 09-A5 1 st Floor 7o.0e
New 09-A5 1st Floor Zone
New 04zA5 1st Floor Zone
New 09-A5 1st Floor 7nna
EnergyPro 4.2 by EnergySoft User Number. 6115 Job Number. Master Set Paw 3 of 10
Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R
Arch Montgomery Res. 9/6/2006
Project Title Data
FENESTRATION SURFACES
0.76
3.5
3.0
1.0 0.1 0.0 0.0
True
Cond.
Location/
# Type Area U-Factorl SHGCZ
Azm. Tilt
Stat. Glazing Type
Comments
4 Window Rioht_(.1QQ -9 0 -87 NEBC_DZO NERC -270 .-SO- New Double Metal Clear Default
1st Floor Zone
2 Window Right (W) 20.0 0.870 NFRC 0_70 NFRC
270 90 New
Double Metal Clear Default
1st Floor Zone
3 Window Right nnn 20.0 0.870 NFRC 0_70 NFRC
270 90 New
Double Metal Clear Default
1st Floor Zone
4 Window Front (N) 20.0 0.870 NFRC 0_70 NFRC
0 90 New
Double Metal Clear Default
1st Floor Zone
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168.
INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin
# Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hqt.
1 Bug Screen
0.76
3.5
3.0
1.0 0.1 0.0 0.0
2 Bug Screen
0.76
6.6
3.0
1.0 0.1 0.0 0.0
3 Bug Screen
0.76
4.0
5.0
1.0 0.1 0.0 0.0
4 Bug Screen
0.76
4.0
5.0
1.0 0.1 0.0 0.0
THERMAL MASS FOR HIGH MASS DESIGN
Run Initiation Time: 09/06106 20:40.46 Run Code: 1157600446
EnergyPro 4.2 by EnergySoft User Number. 6115 Job Number. Master Set Page:4 of 10
Area Thick. Heat
Inside
Condition
Location/
Type
(sf)
(in.) Cap. Cond. R -Val.
JA IV Reference
Status
Comments
Concrete, Lightweight
467
48.00 17
0_36 2
02-A5
New
1st Floor Zone / Exterior Mass
Frame Wall, Stucco
115
6.00 21
0_47 2
09-A5
New
1st Floor Zone / Exterior Mass
Frame Wall, Stucco
223
6.00 21
0_47 2
09-A5
New
1 st Floor Zone / Exterior Mass
Frame Wall, Stucco
164
6.00 21
0_47 2
09-A5
New
1 st Floor Zone / Exterior Mass
Frame Wall, Stucco
243
6.00 21
0_47 2
09-A5
New
1 st Floor Zone / Exterior Mass
PERIMETER LOSSES
Insulation
Condition
Location/
Type
Length
R -Val.
Location
JA IV Reference
Status
Comments
Slab Perimeter
90
None No Insulation
26-A1
New
1st Floor Zone
Run Initiation Time: 09/06106 20:40.46 Run Code: 1157600446
EnergyPro 4.2 by EnergySoft User Number. 6115 Job Number. Master Set Page:4 of 10
Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R
Arch Montgomery Res. 9/6/2006
Project Title Date
HVAC SYSTEMS
Heating Minimum Cooling Minimum Condition Thermostat
Location Type Eff Type Eff Status Type
Res HVAC Central Furnace 380% AFUE Split Air Conditioner 14.0 SEER New No Setback
HVAC DISTRIBUTION
Duct Duct Condition Ducts
Location Heating Cooling Location R -Value Status Tested?
Res HVAC Ducted Ducted Attic
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
4.2 New Yes
WATER HEATING SYSTEMS Rated' Tank Energy Standby' Tank Insul.
Water Heater # in Input Cap. Condition Factor Loss R -Value
System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE' (%) Ext.
AO SMITH PEC -066 Small Gas No Pipe Insulation 1 15,359 60 New 0.87
Multi -Family Central Water Heating Details
Hot Water Pump Hot Water Piping Length (ft) Add 1/2"
Control # HP Type In Plenum Outside Buried Insulation
1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
Casita Addition has two existing 60 ga. water heaters store in the existing 3 car garage for a total of 120 gallons.
n/a n/a
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of
Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality,
and building envelope sealing require installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Name:
Title/Firm: Frank A. Moreno
Address: 79-943 Memorial PI
La Quinta CA 92253
Telephone: 7 0-899-5992
Lic.
�.` • -'-6, -oro
(signature)
(date)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
Documentation Author
Name: Frank A. Moreno
Title/Firm: Power Brokers
Address: 51370 Avenida Bermudas Suite 1
La Quinta, CA 92253
Telephone: (760) 5648470
(signature) (date)
(signature/stamp) (date)
Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R
Arch Montgomery Res. 9/6/2006
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist These Items require special
written justification and documentation, and special verification to be used with the performance approach. The local enforcement
agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the
ioequacy or me specrar /usancaoon ano aocumemaaon suomntea. Plan Field
The Roof "R-38 Roof (R.38.2x14.16) (1)" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual.
HERS Required Verification
Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC-
approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF -4R
installation certificate. Plan I Field
The HVAC System 'Res HVAC' incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -
4R.
The HVAC System 'Res HVAC' incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion
Valve.
This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation.
The Cooling System "Carrier 38TSA02432" includes credit for a 12.1 EER Condenser. A certified HERS rater must field verify the
installation of the correct Condenser.
EnergyPro 4.2 by EnergySoft User Number. 6115 Job Number. Master Set Paoe:6 of 10
Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance
requirements from the Certificate of Compliance superoede the items marked with an asterisk (') below. When this checklist is incorporated into the permit
' 3 . documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory _measures whether
they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Check or initial applicable boxes or check NA If not applicable and Included with the
DESCRIPTION
ENFORCE -
documentation.
NIA
DESIGNER
MENT
Building Envelope Measures
§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling.
❑
❑
❑
§ 150(b): Loose fill insulation manufacturer's labeled R -Value:
❑
❑
❑
§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not
❑
❑X
❑
apply to exterior mass walls).
§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor.
❑
❑
❑
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
a. closable metal or glass door covering the entire opening of the firebox
❑
❑
❑
b. outside air intake with damper and control, flue damper and control
❑
❑
❑
2. No continuous burning gas pilot lights allowed. {
❑
❑
❑
§ 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual
❑
❑
❑
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
❑
❑X
❑
§ 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor
❑
❑
❑
penmeance rate no greater than 2.0 perm/inch.
§ 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include
El
N
El
Forth:
§ 116-17: Fenestration Products, Exterior Doors, and Infittration/Exfiltration Controls.
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
❑
❑X
❑
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
❑
❑
❑
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
❑
❑
❑
Space Conditioning, Water Heating and'Plumbing System Measures
§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission.
❑
❑X
❑
§ 150(h): Heating and/or cooling loads calculated in accordancewith ASHRAE, SMACNA or RCCA.
❑
El'
❑
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
❑
❑
F1
§ 1506): Water system pipe and tank insulation and cooling systems line insulation.
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation
❑
❑X
❑
having an installed thermal resistance of R-12 or greater.
2. Bads -up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external
❑
❑X
❑
insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value.
3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire
❑
❑
❑
length of recirculating sections of hot water pipes shall be insulated to Table 150B.
2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and
❑
❑
❑
indirect hot water tank shall be insulated to Table 150-B and Equation 150-A.
4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A.
❑
❑ -
❑
S. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance,
❑
0
❑
and wind.
6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed
❑
❑
❑
entirety in conditioned space.
7. Solar water -heating systemslcollectors are certified by the Solar Rating and Certification Corporation:
❑
❑
❑
EnergyPro 4.2 by EnergySoft User Number. 6115 Job Number. Master Set
Page:7 of 10
Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent
compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (*) below. When this checklist is incorporated
into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory
measures whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE]
aDDlicable. NIA DESIGNER MENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
§ 150(m): Ducts and Fans
1. All duds and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604,
❑ X❑ ❑
605, and Standard 6-5; supply -air and retum-air duds and plenums are insulated to a minumum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other dud -closure system
that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements
of UL 723. If mastic or tape is used to seal openings greater than 114 inch, the combination of mastic and either mesh
or tape shall be used.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than
❑ ❑ ❑
sealed sheet metal, dud board or flexible duct shall not be used for conveying conditioned air. Building cavities and
support platforms may contain duds. Duds installed in cavities and support platforms shall not be compressed to cause
reductions in the cross-sectional area of the duds.
3. Joints and seams of duct systems and their components shall not be sealed with Goth back rubber adhesive
❑ ❑ ❑
dud tapes unless such tape is used in combination with mastic and draw bands.
4. Exhaust fan systems have back draft or automatic dampers.
❑ ❑ ❑
5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating
❑ ❑ ❑
dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment
❑ ❑ ❑
maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water
retardant and provides shielding from solar radiation that can cause degradation of the material.
7. Flexible duds cannot have porous inner cores.
❑ ❑ ❑
§ 114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the
❑ ❑ ❑
heater, weatherproof operating instructions, no electric resistance heating and no pilot light
2. System is installed with:
a. At least 36" of pipe between filter and heater for future solar heating.
❑ ❑ ❑
b. Cover for outdoor pools or outdoor spas.
❑ ❑ ❑
3. Pool system has directional inlets and a circulation pump time switch.
❑ ❑ ❑
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
❑ ❑ ❑
burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
§ 118 (i): Cool Roof material meets specified criteria
❑ ❑ ❑
Lighting Measures
§ 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table
❑ ® ❑
150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are
electric and have an output frequency no less than 20 kHz.
§ 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,
❑ ❑ ❑
luminaire has factory installed HID ballast
§ 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined❑
X❑ ❑
in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires,
provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires.
§ 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires.
❑ ❑ ❑
OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d).
§ 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages, laundry rooms, and utility rooms
shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are
❑ ❑ ❑
controlled by an occupant sensor that complies with Section 1z19(d) that does not tum on automatically or have an
always on option.
§ 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are
❑ ❑ ❑
certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals.
s
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the
❑ ❑ ❑
same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article
680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d).
4
§ 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and. 147.
❑ ❑ ❑
Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146.
§ 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
❑ ❑ ❑
dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section
119(d).
EnergyPro 4.2 by EnergySoft User Number. 6115 Job Number. Master Set
Page:8 of 10
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Arch Mont ome Res. 9/6/2006
SYSTEM NAME FLOOR AREA
Res HVAC 467
NGINEERING CHECKS 11SYSTEM LOAD
Number of Systems
1
Heating System
Output per System
57,000
Total Output (Btuh)
57,000
Output (Btuh/sgft)
122.1
Cooling System
Output per System
25,000
Total Output (Btuh)
25,000
Total Output (Tons)
2.1
Total Output (Btuh/sgft)
53.5
Total Output (sgft/Ton)
224.2
Air System
CFM per System
1,600
Airflow (cfm)
1,600
Airflow (cfm/sgft)
3.43
Airflow (cfmrron)
768.0
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
26.0 OF
0
Outside
0 cfm
69.4 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
ISensibleFLatent
10,684
CFM
I Sensible
446
11,125
469
281
10,684
0
1,154
986
0
0
0
0
0
0
0
0
0
1,154
986
13,432 469 12 657
Carrier 38TSA02432 18,714 2,312 57,000
Total Adjusted System Output 18 714 2,312 57,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm I Jan 12 am
69.4 of J.I n 105.0 of
�
Heating Coil
Supply Fan
1600 cfm
105.0 of
—iloh Supply Air Ducts
104.4 of
ROOMS
70.0 of
Retum Air Duct
.UULING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
113.1 / 73.1 of 78.7 / 62.0 of 55.0 / 53.4 of 55.0 / 53.4 of
O Supply Air Ducts
Outside Air
0 cfm
Cooling Coil Supply Fan 55.7 / 53.6 of
1600 cfm 40.2% R.H. ROOMS
78.7/62.3 of 78.0 / 62.0 of
ReturnAir Ducts I
EnergyPro 4.2 by EnergySoft User Number. 6115 Job Number. Master Set Pane:9 of 10
ROOM LOAD SUMMARY
PROJECT NAME
Arch Montgomery Res.
DATE
9/6/2006
SYSTEM NAME
Res HVAC
FLOOR AREA
467
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME _
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
1st Floor Zone
1st Floor
1
446
11,125
469
446
11,125
469
281
10,684
PAGE TOTAL 1 446 11,125 469
TOTAL 1 446 11,125 469
281
10,684
281
10,684
EnergyPro By EnergySoft User Number. User Job Number. Master Set Page:10 of 10