Loading...
CONR (06-0918)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT VOICE (760) 777-7012 . FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 7/12/06 fi Application Number: C 06-00000918 9 Owner: Property Address: \_'52050_ MERIWETHER WY EAST.OF MADISON LLC APN: 767-200-998-72 330761- PO BOX 1482 Application description: NEW COMML - OTHER NON-RESIDENTIAL LA QUINTA, CA 92247" Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 159475 ; Contractor: l7 2006Fv- L. Applicant: Architect or Engineer: LUSARDI CONSTRUCTI MPANY..-.-. 1570 LINDA VISTA DRIVE CRYOFLAQUINTA SAN MARCOS , CA 9207 iFtMNiCE DEPT: ` A760)744-3133 Lic. No-: ----=--------- Lic. No.: 207287f ------------------------------------------------------------------------------------------- - - - -- _ LICENSED CONTRACTOR'S DECLARATION' - WORKER'S COMPENSATION DECLARATION , I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing' with _ I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. - _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided ' 11 License Class: A B License No.: 207287 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. - - - Date: Contractor: - I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor .Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: - . I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier NATL FIRE INS Policy Number WC7169394 _ following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to certify that, in the' performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, .�j • - permit to file a signed statement that he or she is licensed pursuant.to the provisions of the Contractor's State and agree that, if I should become subject td t e workers' compensation provisions of Section License Law (Chapter 9,(commencing with Section 7000) of Division 3 of the Business and Professions Code) or 3700 of the labor Code hall fo ith ply with those pro ' ions. " that he or she is exempt therefrom -and the basis for the alleged exemption. Any violation of Section 7031..5 by ' any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:e: 4 1icant: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work; and- the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: 'FAILURE TO SECURE WORKERS' COMPENSATION COVE Els UNLAWFUL,ND HALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, - SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED OUSAND. - and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000)" IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.)" APPLICANT ACKNOWLEDGEMENT ( 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner'of conditions and restrictions set forth on this application. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1. Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application, ( ) I am exempt under Sec. , B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being //�aa/ performed under or following issuance of this permit. `/Date: caner: 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject CONSTRUCTI ENDING AG permit to cancellation. _ I hereby affirm under penalty of perjury that there is a construction lending agency for the performance o e I certify that I have read this application and state that the above information is correct. I agree to comply with all work for which this permit is issued (Sec. 3097, Civ. C.)" - city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this c my to enter upon t above-mentioned property fo 'nsp coon rposes. Lender's Name: ' e� nature (Applicant or Agent): .Lender's Address: t LQPERDIIT LQPERA11T Application Number . . . . . 06-00000918 f. Permit . . . . . . LQPERA11T Application Number . . . . . 06-00000918 Permit . . . . . . BUILDING.PERMIT Additional desc Permit Fee . . . . . 849.50 Plan Check.Fee 552.18 Issue Date . . . . Valuation 159475 Expiration Date 1/08/07 Qty Unit Charge Per Extension BASE FEE 639.50 60.00- 3.5000 ---------------------------------------------------------------------------- THOU BLDG 1.00,001-500,000 210.00 Permit . . . . . . ELEC-NEW COMMERCIAL Additional-des6 -Permit Fee . . . . 66.08 Plan Check Fee 16.52 Issue Date . . . . Valuation 0 t. Expiration Date 1/08/07 Qty Unit Charge Per Extension BASE FEE .15:00 .2554.00 .0200 ----------------------------------- ELEC 7 ----------------------------------------- GARAGE OR NON-RESIDENTIAL 51.08.' Permit . . . . . . GRADING PERMIT Additional desc Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation Q Expiration Date 1/08/07 Qty Unit Charge Per Extension BASE FEE 15.00 Permit, . . . ... . MECHANICAL Additional desc Permit Fee 204.00 Plan Check Fee 51.00 Issue Date . . . . Valuation . . . . 0. Expiration Date 1/08/07 'Qty Unit Charge Per Extension, BASE FEE 15.00 3.00 9.0000 EA MECH FURNACE <=100K 27-00 3.00 9.0000 EA MECH B/C <=3HP/100K BTU 27.60 7.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 115.50 3.00 6.5600 ---------------------------------------------------------------------------- EA MECH VENT FAN 19.50 Permit . . . . . . PLUMBING I LQPEPM11T Application Number 06-00000918 Permit PLUMBING Additional desc.. Permit Fee . . 120-.00 Plan Check Fee 30.00 Issue Date . . . . Valuation 0 Expiration Date 1/08/07 Qty Unit Charge Per Extension BASE FEE .15.00 6.00 6.0000 EA PLB FIXTURE .36.00 1.00 15:0000 EA. PLB BUILDING SEWER 15.00 3.00 7.5000 EA PLB WATER HEATER/VENT 22.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 7.5000 EA PLB OTHER BACKFLOW <=2 INCH 7.50 2.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 6.00 1.00 15.0000 EA PLB GAS METER ------------------------------------------------------------------------ 15.00 Special Notes and Comments -. 2554 sq. ft.COMM BUILDING,TYPE V-N,OCCUPANCY B&M OCCUPANCY LOAD 63,SPRINKLERS'N0,776 SQ. FT. PATIO. March 24, 2006 4:57:02 PM jjohnson ---------------------------------------------------------------------------- Other Fees ACCESSIBILITY PLAN REVIEW 55.22 ART IN PUBLIC PLACES -COM 1018.72 DIF CIVIC CENTER - COMM 223.11 ENERGY REVIEW FEE. 55.22 DIF FIRE PROTECTION -COMM - .66.60 STRONG MOTION (SMI) - COM 43.62 DIF STREET MAINT FAC -COMM 432.89 DIF TRANSPORTATION - COMM 10755.90 Fee summary Charged Paid Credited Due -- - - - - - - - - - -- -- - - - ---- Permit Fee Total 1254.58 .00 .00 -- - - - - - - 1254.58 Plan Check Total 649.70 .00 .00 649.70 Other Fee Total 12651.28 .00 .00 12651.28 Grand Total '14555.56 .00 .00 14555.56 Mc ;al Coachella Valley Unified School; District ;,,;5 Box For District use only 83-733 Avenue 55, Thermal, CA 92274 DEVELOPER FEES PAID (760),398-5909 - Fax (760) 398-1224 AREAS .. _ AMOUNT . LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION -AMOUNT: COMM/IND. AMOUNT: - DATE: RECEIPT:. CHECK #: INITIALS: CERTIFICATE OF COMPLIANCE . (California Education Code 17620) Project Name: Reception, Center;. Date: 12/19/06 Owner's Name: East of Madison, LLC Phone No. 760-393-5288. Project Address: 52-050 Meriweather Way, La Quinta, CA Project Description:. 1Commercial Building APN: 676-200-003 Tract #: _ Lot #'s: Type of Developments. Residential Commercial XX Industrial .. Total.Square Feet of Building Area:. .2554 SQ FT • . Certification of Applicant/Owners:. The.person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. .Dated: Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE �ENN R WILL BE SATISFIEDIN ACCORDANCE WITH ONE OF THE FOLLOWING:, (CIRCLE ONE) Education Code Gov. Code '. Project Agreement Existing Not Subject to Fee ." 17620 65995 Approval Prior to 1/1/87' Requirement Number of Sq.Ft. � 2554 sq. ft.._. � � • Amount per Sq.Ft. $ � 0.42 .. . Amount Collected $ 1072.68 Building Permit Application Completed: Yes/No By: •Carey M. Carlson, Asst. Supt., Business Serv ices - Certificate issued by: Maria L. Angulo, Facilities Secretary Signature: A --AX 1\ NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES ANDS STATE NT'OF FEE�J Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (l) a written notice to the project :appellant; at the time of payment of school fees, mitigation payment or other exactions (G°Fees"), of the 90 -day, period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to . " . advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of.the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount.of the fees imposed is as herein set forth, whether payable at this time or in whole, or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. .This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District; and up ' to three (3) such extensions may be granted. At such time as this Certificate expires, if.a building permit has not been issued fo'r the. project that is the -subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Cert ificate of Compliance. LT:c/mydocs/devfees/certificate of compliance furan tablesTO WSG.doc _ 1/16/03 T I P.O. Ox LA 1504 LA QUINTA, CALIFORNIA 92247-1504 BUILDING, & SAFETY DEPARTMENT OF'T19� 78-495 CALLE TAMPICO (760) 777-7012 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 September 11, 2006 Ms. Cynthia.Zamorez The Hideaway / Madison Club (via e-mail) RE F lAh' Review Extension Request — 52050"Meriwether Way (Reception Center), Dear Ms. Zamorez I have reviewed your e-mail letter dated 8/30/06, *requesting a time extension for the Plan Review of the Reception Center at the above address submitted under Application number 06-918: Plan review status: Original application date: 3/3/06 180 -day expiration date: 8/30/06 180 -day extension date: 2/26/07 Under the provisions of California Building Code Section 107.4, your request is hereby granted. Because the Building Code specifies that "no application shall be extended more than once," please be advised that unless a building permit for this project is issued on or before Monday, February 26, 2007, your application will expire automatically." Yours truly, Greg Butler Building & Safety Manager Greg Butler From: Cindy Zamorez [czamorez@madisonclubca.com] Sent: Wednesday, August 30, 2006 4:21 PM To: Greg Butler. Subject: THe Madison Club.(Reception Center); Permit Extension Request Greg: Upon review of our plan status, it appears that the imposed 180 days causes our ability to pull a. permit for the Reception Center (52050 Meriwether Way). It expires today. We originally applied on March 3, 2006. We have everything in place to pull the permit (including the okay from Building and Safety), except for .the signed green sheet from Public Works. Public Works have. required that we obtain written approval of some very minor landscaping encroachment before they will approve/sign the Precise Grading for the Reception Center. It takes several weeks to obtain their approval so without it, I can not proceed with pulling the permit, therefore, I am requesting an extension on the time to pull the permit. Please do not hesitate to give me a call if you have any questions. or need additional information. My number is (760) 393-5288. Thank you for your assistance in this matter. Cynthia Zamorez The Hideaway/Madison Club c JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 �- INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS WELDING INSPECTION REPORT Date: 1/3,�o,7 .: Project Name: Project No: ?,lf:,:r ,1, "�J L Project Address: City: AWS IBC QD1.1 E] Title 24 E] D 1.3 E] Other Client: Sub -Contractor: D 1.4 General Contractor: Architect: Structural Engineer: e ' n "I'— .. /z' /g fir e� �C._,e t . r_ rt- rA . rs .QTS Shop Description of Work Inspected:""- 41© Field r ; .• Unresolved Items: EJ None E] See Below `/ s 7, /J !t ! %%� / ,/� . ? � )CI J t / 1112 e "'n. e_3 t/�C��T- S i%Cr?./-7= -y-:4 T'. S/C/�.>. \/' A T_ i-'' / 1 CniZ�rz�,r�= /-\i i / /�7C /^'?� l i /7 /r �— e r _ r ( �' �. a� /.� ./� s''.% r / r h �Yf T7 rr ,/�L. i-�,L,/ � 1 � 7Y�. , c _ � ...-J�! ✓I , „_ i � l ) /. % i e / i 1'9 ,/� � \. ^ F „ r %� `c-+, r/_ Cert on File Electrode Process Welder Detail(s) Location/Comments Yes No Type Size /1 .4c ,c. 6 -lc '_nk n 4 /.t L,c A-" I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications applicable building laws. Final report issued at project completion. Inspector: Steven T. Wood AWS'Certification No: 03100321 Contractors Representative: Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page / of / ( JCM Inspections ; 39725 Garand`Lane.Suite F Palm Desert, CA 92211: INSPECTIONS Phone: 760-345-555.4 _ - • Fax: 760-772-3895 INSPECTION S - REINFORCED CONCRETEINSPECTION REPORT,', ` Date: Project Name: Project No: Project Address: v :, City: . ` �, .. �ii.1 � � •��.A' �`T �.-1 \ . 1 �• i'� K�Q. ��ii C+ � wM1JI ��rt •! \ Q .��^ .� Client: Sub -Contactor: •. A General Contractor: .,, Architect: ' Structural Engineei..'.. • • .. ; i �nsC � � '�i' �S'SaC�\>w ac AI t1 • tl��s�or1' a�S, Slump (inches): L� ,aS . ' Supplier: D C�CTc�I �o g��'� •�`�. 'IBC Time Sampled: ; pS"� �.-� Mix Design: ' S (0 �•J • EJ Title 24 Time in Mixer (min.): 1�- Specified Strength (PSI):j a Other: + Water Added @ Jobsite (gals.): Addmixture: Unresolved Items: Concrete Temperature (F): Truck ii:Ticket #: j�,a ��. El -None Ambient Air Temperature (F): Field ID Markin AA SQ gti— c. 0 See Below Location of Sample: No Samples Taken Description of Work Inspected: CIA . - V". ,N�a .�.t �G� C)Tc n'c c • i� \ ha r:� t, tz w. o '�C • o�: �`'o �� c c.o �¢�. "�o c b _ ` is �C C tS, u •r•r� r.+ ��c�.� • �b L1T c 49 Q'C C.: t�:r•t�(' l► , `1 a �1 �``\`. � � 'A r� � tl.iL \ _ i �ti O.eV O . �R3 �.t 'tiA A✓� !L_Or b o :< Ci o [/�1��' \\\\+,^` �Fl.ni�V'11f"� �'• .i�CWA.J ,t_i�4�Al �� \.i1 �CA \�!\li.� �"`�4. •4� �. ��• J t � /_' . .•.gyp;. L�G-dvCt+\�'C! \�t\1�F%��. �hr CJ1`b�0.�11J C,C)++� 'tC'SSl t��n / • �[ .��Q �� ��i3,.iA.�l� 1. iL nnn �'r.�n AJ i'ri°cDc�� . ' .� ' I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this 'work .to comply with the approved plans, specifications applicable building laws. Final report issued at project completion., . F Inspector: Jack'C,. M�illin(� ICC Certification No: 0842216-49 Contractor's Representative- /. Copy 1 JCM Inspections ; ',.Copy 2 Project Superintendent Copy 3 Governing Agency '• Page' of JCM Inspections 39725 Ga"rand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS REINFORCED CONCRETE INSPECTION REPORT Date: Project Name: Project No: s aa- Project Address: City: �l u v Client: Sub -Contractor: S\(iC`�\Qfl TNCC%1q_14:1C fy\ General Contractor: '� Architect: Structural Engineer: Slump (inches): Supplier: Q'IBC Time Sampled: Mix Design: ❑ Title 24 Time in Mixer (min.): Specified Strength (PSI): Other: Water Added @ Jobsite (gals.): Addmixture: Unresolved Items: Concrete Temperature (F): Truck #: Ticket #: ❑ None Ambient Air Temperature (F): Field ID Marking: See Below Location of Sample: --� �V No Samples Taken Description of Work Inspected: �o\Ro?.!r,rS� e t c. n X r"\ t l .,n Ci o c C 1:.- /1 f t.T7'Fl tl (' n e'� t In e_ i5` � f O ur c rN,ti I..`!;0 . C_ '�"`�Ouc�-� cS.. \"�` n.-a� Cece a+ . f r� . <eR re f t• � n r� �i,Cr c c�, Oa fit? 'XI � 1'�� 4.. -�C n '1.,C� o -Q v + r 1r41Q c c_ n %,I c., - w c_ C a (l..c., d0 ?Y -I$ C' i, - ,+n C. ��t)C— 3�t1� �0 .,u 8f'o r►��r,., A\ "%PC a _-A peck. ?k k .#00 C14 rte,P GAAG QQ ZA n r Q1 CAq 40 tv CIA-.,',\ q � Y ✓�� rr C t.a('a �4t^al\ K �%wfra Coca c��w.1 � ~ \(��i p� (� (� 1 'K3-v\rK� €�Cant� �'k1��.r�faCra1(71 V_n 0C �e\� WAS �� w.,�elcclJ �f�+. �1�L. � � (� "Z��ZnC* 4=, r Q N� .�,. s ��. 4t',!1 n :. n. 0 r Thor- C 11\ kp.t s.l+ i('� rXt"M t �(� J I—) ' G CCS A Q5X , f7 C IDO t C P `,Q+ Y I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector: Jack•. Millin(�ICC Certification N"o: 0842216-49 !_ C_" � - q -' Contractor's Representative: (t A bk G.�� J�i^ Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page —Lof 1 VV JCM�Inspections • 39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS I Phone: 760-345-5554 - Fax: 760-772-3895 _ a INSPECTIONS W'.. WELDING INSPECTION REPORT Date: 2��7 Project Name: Project No: 522-4810 The Madison Club - Reception Center Project Address: City: 52-050 Meriweather Way La Quinta, CA AWS ❑✓ IBC Q D 1.1 ❑Title 24 ❑ D 1.3 F] Other ❑ D 1.4 Client: Sub -Contractor: Sladden Engineering 1/i1, rz`'5 s;z z General Contractor: Architect: Structural Engineer: Lusardi Const. NFA / Nick Fullerton, Architects Langston & Assoc Description of Work Inspected:�^-1�S�Ci�77�c� ,© Shop E]Field T C,/f 41,J j --T-.- �,��G-Zr^y�.� �r✓j v� Unresolved Items: E] None ❑ See Below Z iJr%S /�C !-I �� % 5=� r� 1� C L-r� rC ✓� S�+av�� C_ r �-S Cc l�-/C. Z r� S Ali S vr�C L `-f r' Process Welder Cert on File Electrode Detail(s) Location/Comments - '1 Yes No Type Size y 4-70.1y Y �rrY«sr" I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector: Steven T. Wood ,AWWSSCertification No: 03100321 Contractor's R`epresentative: / Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page /of / VJCM inspections'* 39725 Garand Lane Suite F I Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 I. _ INSPECTIONS WELDING INSPECTION REPORT Date: // ,/7 Project Name: Project No: 522-4810 The Madison Club - Reception Center Project Address: City: 52-050 Meriweather Way La Quinta, CA AWS F✓ IBC Q D 1.1 Title 24 ❑ D 1.3 Other ❑ D 1.4 Client: Sub-Contractor: Sladden Engineering 1,1,e,TL :S General Contractor: Architect: Structural Engineer: Lusardi Const. NFA / Nick Fullerton, Architects Langston & Assoc Description of Work Inspected: im"e `❑ Shop Field Unresolved Items: ❑ None ❑ See Below /orf/) �� S=�i�'�G / �L/-a , /-1/:c. IS = Qin l� k X /% LA//(JO/S — /l:^J C_ IX l5/ -T e- 37- � \ `�.s p !.��'t /� z %�/ze � �S /-72/1 atiI) / 1,,77, -1 1T2/'2,'%c�hs -�\>i 7 c - � 7'7- -A lc/c r- er?- .c/ 5 /One? - - ,16rvC-- /rf /7 F /0 C CC / )'moi-77J LCA r�..Jr� �G/la r,�G ✓.A.etdT N , W Process Welder Cert on File Electrode Detail(s) Location/Comments s s' Yes No Type Size ScJt� c- r /i2L S I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector: Steven T. Wood' AWS,Certification No: 03100321 ---------, Contractor's Representatiye: Z, C Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page / of / •�JCM�Inspectioris G 39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554, - Fax: 760-772-3895 INSPECTIONS WELDING INSPECTION REPORT Date: Z/3/�7 Project Name: Project No: 522-4810 The Madison Club - Reception Center Project Address: City: 52-050 Meriweather Way La Quinta, CA AWS Q✓ IBC ® D 1.1 Title 24 D 1.3 Other ®D 1.4 Client: Sub -Contractor: Sladden Engineering General Contractor: Architect: Structural Engineer: Lusardi Const. NFA / Nick Fullerton, Architects Langston & Assoc Description of Work Inspected:/ T7J� Q Shop ❑Field T <� !!:V A Jl Unresolved Items: Q None ❑ See Below i� 3/ �! 4 ,. 3 r r's? z-�\c -7 \ ?5/1'e A/1 77 / /�!/ i- ,C-/ % C� /OCC Y�7=7 i . [ -`. 6 C � /�/ G (_ -' i 1A le Z - � f � �xtrr,��� A/.�- i /G✓ }.' �,l IR. 4 7 .\ J/i Process Welder Cert on File Electroder Detail(s) Location/Comments * Yes No Type Size iSMr-a� Y-4 C"$ -r"W J E STle-41�14 .2 3 2. SZ V i.-4,__/ 4 UV/5 C'-0 2" 2 sz / I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector: Steven T. Wood AWS, Certification No: 03100321 Contractor's Representative: Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page / of / Certificate of Occupancy OF Building & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, � at the time of issuance, this structure was in compliance with the ; provisions of the Building Code and the various ordinances of the City regulating building i construction and/or use. s E BUILDING ADD RESS:r52=050!N[ RIWETHER W Use classification: COMMERICAL (RECEPTION CENTER) Building Per No.: 06-918 r Occupancy Group: B & M Type of Construction: VN Land Use Zone: RL — — i� �i Owner-of Building:.EAST OF MADISON LLC Address: P.O. BOX 1482 �I r I City, ST, ZIP: LA QUINTA, CA 92253 E By: STEVE TRAXEL Date: 09-24-2007 Building Official POST IN A CONSPICUOUS PLACE JECEtnft-TIFICATE OF COMPLIANCE (Part I of 2) ENV -1-C PROJECT NAME MADISON CLUB - RECEPTION BUILDING Sept. 30, 2007 DATE 02/21/2006 PROJECT ADDRESS LA QUINTA, CALIFORNIA PRINCIPAL DESIGNER -ENVELOPE TELEPHONE Building Permit# DOCUMENTATION AUTHOR DREAM ENGINEERING INC. TELEPHONE (909) 475-9900 Checked by/Date Enforcement GENERAL INFORMATION DATE OF PLANS 02/21/2006 BUILDING CONDITIONED FLOOR AREA 2,185 SQ. FT. CLIMATE ZONE 14 BUILDING TYPE ® NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEL/MOTEL GUEST ROOM ❑ RELOCATABLE - Indicate: ❑ specific climate - list or ❑ all climates PHASE OF CONSTRUCTION ® NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION ❑ UNCONDITIONED (file affidavit) METHOD Lit- ENVELOPt ICR ,.,, I COMPLIANCE SUPPORTING FORMS SUBMITTED N ENV - 2� (Component) ❑ ENV - 3-C (Overall Enveloae) F1 ENV--C(Skvliaht Worksheet) TEMENT OF This Certificate of Compliance lists the building features and performance specifications need to comply with 1 and 6 of the California Code of Regulations. This certificate applies only to building envelope requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR SIGNATURE DATE JOSEPH M. NOLAN Use with the Envelope Component compliance method. Sept. 30, 2007 ne r-nncipai tnvempe ueslgner nereoy cenmes inai ine propowa building design represented in this set of construction documents is consistent with the other compliance fomtis and worksheets, with the specifications, and with any other calculations submitted with this permit application. the proposed building has been designed to meet the enve requirements contained in sections 110, 116 through 118, and 140, 142, 143 or 149 of Title 24, Part 6. i Please check one: I hereby affirm that I am eligible under the provisions of Division 3 of the business and Professions Code to ❑ document as the person responsible for its preparation; and that I am licensed in the State of California as a engineer or mechanical engineer, or I am a licenseR� arch' ect. ❑ I affirm that I am eligible under the provisions of ¢iviGipOp'-131?f a sand Professions Code by section 6737.3 to sign this document as the person responsibllefrio ••%�n am a licensed contracti performing this work. J G SA �'1 `fIN-r c z. this I 0 17.2 oP ❑ 1 affirm that I am eligible under Division 3 of the Business" n s or% y g dr rtCoct�pig this document bec�,u pertains to a structure or type of work described, as exe trp�y Mus s and rofessions Code;Seetl 37, 5538 and 6737.1. / DAT/? �crioN �C hese sections of the Business and Professions CCoode-a fio {� n I i the Nonresid etial Manua . G rm INCIPAL ENVELOPE SIGNATURE DA E L . # SEPH M. NOLAN `-S pt. 30, 2007 E933'3coo ENVELOPE MANDATORY MEASU Indicate location on plans of Note Block for Mandatory Measures EM8 fry TIONS TO APPLICANT FENV-1 Certificate of Compliance. Required on plans for all submittals. Part 2 may be incorporated in schedules on plans. ® ENV -2-C Use with the Envelope Component compliance method. ❑ ENV -3-C Use with the Overall Envelope compliance method. ❑ ENV4-C Optional. Use for the minimum skylight requirements for large enclosed spaces. 2005 Nonresidential Compliance Fomxs September 2005 CEkTIFICATE OF COMPLIANCE (Part 2 of 2) ENVA -C PROJECT NAME MADISON CLUB - RECEPTION BUILDING DATE 02/21/2006 OPAQUE SURFACES Surface Type Area U -factor Insulation Cavity Continuou Actual Tilt Condition statue JointApp IV Reference LocatiONCorrurmirts (e -g. Suspended Ceiling, Demising, etc.) NOTES TO FIELD For Building Dept Use Onl NORTH WALL 630 0.166 R-21 - 0 90 - - EAST WALL 342 0.166 R-21 - 90 90 - - SOUTH WALL 630 0.166 R-21 - 180 90 - - WEST WALL 342 0.166 R-21 - 270 90 - - CEIUNG 2544 0.148 R-38 - 0 0 - - FLOOR 2544 SLAB 0 0 - - N,E,A, (New, Existing, Altered) FENESTRATION SURFACES More than or equal to 10,000 sq. ft. of stie-built fenestration area must include a label certificate issued by NFRC or Provide a CED Default Label Certificate using the default U f4dors from Standards Tables 116-A and B. Certificate shall be filed in the contractor's project office during construction and in the building manager's office after construction. Fen. # Fenestration Type Area U -factor U -factor Type (1) Fenestra SHn� SHGC Type (2) Condition Status Location/Comments NOTES TO FIELD- For Bldg. Dept Use OnlyNTA MINIMUM SKY LIGHT AREA FOR LARGE ENCLOSED SPACES LJ The proposed building contains an enclosed space with floor area greater than 25,000 sq. ft., a ceiling height greater than 15 feet, and an LPD for general lighting of at least 0.5 W/sq. fL If this box is checked, ENV-" must be tilled out . NOTES TO FIELD - For Building Department Use Only (1) U -factor Type: D, A or N (D for Default Table from Section 166, A for ACM Manual Appendix Default Table, or N for NFRC Labeled) (2) SHGC Type: D, C or N (D for Default Table from Section 116, C for Center of Glass, or N for NFRC) (3) Condition Status: N, E, or A (New, Existing, or Altered.) EXTERIOR SHADING Fenestration No. Exterior Shade Type SHGC mow Overhang Height Width Length Height LExt RExt MINIMUM SKY LIGHT AREA FOR LARGE ENCLOSED SPACES LJ The proposed building contains an enclosed space with floor area greater than 25,000 sq. ft., a ceiling height greater than 15 feet, and an LPD for general lighting of at least 0.5 W/sq. fL If this box is checked, ENV-" must be tilled out . NOTES TO FIELD - For Building Department Use Only ­, 1-111 a —jual w,u„lN,folu'v r-vlurb - September2005 ENVELOPE COMPONENT METHOD (Part 1 of 2) ENV -2-C MADISON CLUB - RECEPTION BUILDING 02121/2006 WINDOW AREA CALCULATION SF SKYLIGHT GLAONG A. DISPLAY PERIMETER 240 FT x 6 FT= 1440 DISPLAY AREA (ALONG SIDEWALK) V With No Curb V Plastic B. GROSS EXTERIOR WALL AREA SF x 0.40 = 1555 SF 40% of GROSS EXTERIOR ALLOWED 3888 AREA C. ENTER LARGER OF A OR B 1555 SF MAXIMUM ALLOWABLE AREA D. ENTERPROPOSED WINDOW AREA PROPOSED WINDOW AREA 162 SF If the PROPOSED WINDOW AREA is greater Om the MAXIMUM STANDARD AREA then the envelope component method may not be used. E. WINDOW WALL RATIO proposed Window Area Divided by Gross Exterior Wall Area F. WEST DISPLAY PERIMETER 293 FT x 6 FT=1758 SF WEST DISPLAY AREA (ALONG SIDEWALK) 17 G. WEST EXTERIOR WALL AREA 3888 SF x 0.40 = 1555 40% of WE ST EXTERIOR WALL SF AREA H. ENTER THE LARGER OF F AND GF MAXIMUM STANDARD WEST 1555 SF AREA I. ENTER PROPOSED WEST WINDOW AREA 1 293 PROPOSED WEST WIN30W AREA If the PROPOSED WEST WINDOW AREA Is greater than the MAXIMUM STANDARD WEST AREA then the envelope component method may not be used. J. WEST WINDOW WALL RATIO = Proposed West Window Area Divided by West Exterior Wall Area = SKYLIGHTARBI CALCULATION A. ATRIUM or SKYLIGHT HEIGHT B. IF AtriumiSkylight Height in A<_55 FT C. IF Height in A > 55 FT D. PROPOSED SKYLIGHT AREA GROSS ROOF AREA NIA SF x 0.05= NIA SFx0.10= STANDARD ALLOWED SF If the PRDPOSD SKYLIGHT AREA is greater than the STANDARD ALLOWED SKYLIGHT AREA then the envelope component method may not be used. SKYLIGHTS SKYLIGHT NAME e.g., Sky -1, Sky -2) SKYLIGHT GLAONG # OF PANES U -FACTOR SOLAR HEAT GAIN COEFFICIENT With Curb V With No Curb V Plastic PROPOSED ALLOWED PROPOSED ALLOWED ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ FA RELOCATABLE PUBLIC SCHOOL BUILDINGS See§143(a)8 in the Energy Standards ❑ For Specific Climate Zone, use Table ❑ Specific timate Zone Metal Identification Label — Place two labels on each 143-A - Prescriptive Envelope Criteria. relocatable building and indicate on the building plans. ❑ For Any (All) Climate Zone, use Table ❑ Any (All) Climate Zone Metal Identification Label - Place two labels on each 143-C - Prescriptive Envelope Criteria. relocatable building and indicate on the building plans. 2005 Nonresidential Compliance Fomm September 2005 MANDATORY MEASURES ENVELOPE Any new construction in a low rise residential building shall meet the requirements of this Section. Xceiliny Insulation j - Installation of Fireplaces, Decorative Gas Appliances and f 'Gas Logs The opaque portions of ceilings separating conditioned spaces from unconditioned ; 1. if a masonry or factory built fireplace is installed, it shall have the following: — spaces or ambient air sh oil be insulated between wood framing members with insulation resulting in on installed thermal r6sistance of R — 19 or greater for the - A. Closeable metal or glass doors covering the entire opening of the firebox; insulation alone. B. A combustion air Intake to draw air from the outside of the bui Iding directly Into the a Wall insulation .- _� firebox, which is-at least six square Inches in area and is equipped with a readily accessible, operable, and .tight fitting damper or — combustion — air control device; and Wood framed walls shall be insulated between framing members —.with insulation having C. A flue damper with a readily accessible control. an Installed thermal resistance of R — 13 or greater. Framed foundation walls of heated basements or heated crawl spaces shall be insulated above the adjacent outside ground L _ 2• Continuo us burning pilot lights and the use of Indoor air for cooling a firebox Jacket, line with` insulation having an Installed thermal resistance of at least R — 13. when that indoor air is vented to the outside of the building, are prohibited. (f) Air Retarding Wrap. If on air retarding wrap is installed to meet the requirements of 0".NRalsed-floor Insulation Section 151, it shall meet the requirements specified in the Residential ACM Manual.. Raised floors separating conditioned space from unconditioned space shall be Insulated between wood framing members with insulation having on — installed thermal resistance of R-13 or greater. X Exterlor Doors And Fenestration Products Certification of Fenestration Products and Exterior Doors other than Field fabricated. — Vappr Berries In Climate Zones 14 and 16, o barrier be installed the Any fenestration product and exterior door, other than field fabricated fenestrat ion vapor shall on conditioned space side of all insulation in all exterior walls, unvented attics, and unven ted crawl spaces to products and field fabricated exterior doors, may be installed only if the manufacturer has certified to the commission, or if an independent certifying organization approved by the protect insulation from condensation. If a building has a control ventilation crawl space, a vapor barrier shall be placed over the earth floor of the crawl space to reduce moisture commission has certified, that the product complies with all of the op plicable entry and protect insulation from condensation, as spe ciflied in the alternative to equirements of the Standards. Section 150 (d). 1 CERTIFICATE OF COMPLIANCE (Part 1 of 3) MECH-1-C PROJECT NAME MADISON CLUB - RECEPTION BUILDING JOSEPH M. NOLAN DATE 02/21/2006 PROJECT ADDRESS LA QUINTA, CALIFORNIA PRINCIPAL DESIGNER -ENVELOPE TELEPHONE Building Permit# DOCUMENTATION AUTHOR DREAM ENGINEERING INC. TELEPHONE (909) 475-9900 Checked by/Date Enforcement GENERAL INFORMATION DATE OF PLANS 02/21/06 BUILDING CONDMONED FLOOR AREA 2,185 SO. FT CLIMATE ZONE 14 BUILDING TYPE ® NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEUMOTEL GUEST ROOM PHASE OF CONSTRUCTION ® NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION ❑ UNCONDITIONED (file affidavit) METHOD OF MECHANICAL COMPLIANCE ® PRESCRIPTIVE ❑ PERFORMANCE PROOF OF ENVELOPE COMPLIANCE ❑ PREVIOUS ENVELOPE PERMIT ® ENVELOPE COMPLIANCE ATTACHED STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications need to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building mechanical requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR SIGNATURE 2I JOSEPH M. NOLAN �J '04V SEPT. 30, 2007 The Principal Mechanical Designer hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. the proposed building has been designed to meet the mechanical requirements contained in sections 110 through 115, 120 through 124, 140 through 142, 144 and 145. Please check one: ❑ 1 hereby affirm that I am eligible under the provisions of Division 3 of the business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or mechanical engineer, or I am a licensed architect ❑ 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that 1 am a licensed contractor performing this work ❑ 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. These sections of the Business and Professions Code are printed in full in the Nonresidential Manual. PRINCIPAL MECHANICAL DESIGNER -NAME I SIGNATURE DATE I LIC. # MECHANICAL MANDATORY MEASURES n on Dlans INSTRUCTIONS TO APPLICANT EM ror ueraueo instructions on the use of this and all Energy Efficiency Standards compliance fom7s, please refer to the Nonresidential Manual published by the Calitbmia Energy Commission. ® MECH-1: Required on plans for all submittals. Pan` 2 may be incorporated in schedules on plans. ® MECH-2: Required for all submittals, but may be incorporated in schedules on plans. ® MECH-3: Required fior all submittals unless required ventilation rates and air flows are shown on plans, see 4.3.4. Ref plans. ❑ MECH-4: Required for all prescriptive submittals. ❑ MECH-5: Optional. Performance use only for mechanical distribution summary. 2005 Nonresidential Compliance Forms September 2005 PROJECT: ' MADISON CLUB - RECEPTION BUILDIN LA QUINTA GROSS EXPOSED WALLS FIXED WINDOWS SLIDING WINDOWS WINDOWS 8 GLASS DOORS: SKY LIGHTS OPAQUE DOORS NET EXPOSED WALL AVE CEILINGS CEILINGS (R#2) FLOOR (SLAB - PERIMETER) FLOOR (RAISED FLOOR) SUBTOTALBTU HLOSS DUCT BTUH LOSS (15%) HEATING: TOTAL BUTH LOSS PEOPLE 8 APPLIANCES SENSIBLE BTU GAIN DUCT BTU GAIN (15%) SUM OF SENSIBLE AND DUCT GAINS COOLING: TOTAL BTUH GAIN (TOTALX 1.3) HTG UNIT SIZING= CLG UNIT SIZING= X HEATING EQUIPMENT EFFICIENCY PERT -24 SECTION 112(a) x COOLING EQUIPMENT EFFICIENCY PER T-24 SECTION 112(x) x HEAT PUMP THERMOSTAT PER T-24 SECTION 112(b) FURNACE CONTROL PER T-24 SECTION 112(c),155(a) VAV MINIMUM POSITION CONTROL PER T-24 SECTION 112(c) FORM J EQUIPMENT LOADS 56 BTU/SQ FT DREAM ENGINEERING INC. 2185 SQ FT SAN BERNARDINO, CA CA HTM HTM AREA/ BTU CLG HTG LENGTH CLG 25 0 0 26 976 0 NORTH 25 301 7530 EAST 70 211 14763 SOUTH 35 238 8314.78 WEST 70 226 15845.9 0 0 -0 0 38 25 28 1064 R21 1.8 1.9 216 389 R38 1.49 0.8 2185 3264 0 0 28.3 •0 0 0 0 0 13157 64328 9649 73978 96171 BTUH LOSS X 1.3+110X AREA= BTUH GAIN X 1.15 = 2700 N. LITTLE MOUNTAIN DR. SUITE G-105 (909)475-9900/F8828 BTU NUMBER OF FLOORS HTG EXPOSED WALL (SQ FT) FOOTPRINT - PERIMETER (FT) 0 BUILDING DIMENSIONS (SQ FT) 25279 CEILING HEIGHT(FT) DIRECTION FACING LOCATION SUMMER DESIGN OUTDOOR - 78 WINTER DESIGN OUTDOOR -68 0 UBC 50% OCCUPANCY 700 DISCLAIMER: 410 1.THE BUILDING HEAT LOSS 8 RESULTING MAXIMUM HEATING 1835 EQUIPMENT OUTPUT CALCULATIONS IN THIS REPORT MEET THE 0 CRITERIA OF TITLE 24. THIS MAXIMUM MAYBE EXCEEDED 0 WHEN THE FURNACE IN THE SELECTED PRODUCT LINE MUST BE 0 LARGER TO MEET COOLING LOAD AIR FLOW REQUIREMENTS. 28225 27HE BUILDING SENSIBLE HEAT GAIN CALCULATED IN THIS 3387 REPORT MEETS THE CRITERIA OF TITLE 24 AND MAYBE 31612 USED BY THE MECHANICAL CONTRACTOR IN EQUIPMENT SELECTION AND SYSTEM DESIGN. THE ARI STANDARD 210 ' RATED CAPACITY OF THE EQUIPMENT SELECTED MAY NEED TO BE HIGHER THAN THAT STATED IN THE CALCULATIONS BECAUSE THE DESIGN CONDITIONS FOR THE LOCATION ARE DIFFERENT FROM THE TEST CONDITIONS USED IN THE RATINGS. 61073 BTU HEATING OUTPUT, MINIMUM REQUIRED 121439 BTU COOLING SENSIBLE, MINIMUM REQUIRED MANDATORY MEASURES MECHANICAL Any new construction in a tow rise residential building shall meet the requirements of this Section. X NATURAL VENTILATION PER T-24 SECTION 121(b) X MINIMUM VENTILATION PER T-24 SECTION 121(b) x DEMAND CONTROL VENTILATION PER T-24 SECTION 121(c) xTIME CONTROL PER T-24 SECTION 121(c), 122(e) X SETBACK AND SETUP CONTROL PER T-24 SECTION 122(.) Jul OUTDOOR DAMPER CONTROL PER T-24 SECTION 122(0 X ISOLATION ZONES PER T-24 SECTION 122(8) X PIPE INSULATION PER T-24 SECTION 123 X DUCT INSULATION PER T-24 SECTION 124 1 3888 216 2185 18.0 SOUTH LA QUINTA 112 32 15 AIR SYSTEM REQUIREMENTS PROJECT NAME '%LJI.7V/r VLVO — r[1=liC1 ITEM or SYSTEM TAG(S) (Part 1 of 3) MECH-2-C AIR SYSTEMS, Central or Single Zone HP 1,2,3 MANDATORY MEASURES Se-ct4ton Reference on plans an specs. Heating Equipment Efficiency a 80% Cooling ul menEfficiency a 13 SEER Heat Pump Thermostat 112(b) N Furnace Controls 112(c), 115(a) TSTAT Natural Ventilation 121(b) Air Balance inimum Ventilation 121(b) 328 CFM AV Minimum Position Control 121(c) N emand Control Ventilation 121(c) N ime Control 121(c), 122(e) Y etback and Setup Control 122(e) Heating & Cooling Required Outdoor Dampgr Control 122(f) Auto Isolation Zones 122(g) 0 Pipe Insulation 123 Y r)ijct Insulation 124 4.2 PRESCRIPTIVE MEASURES MUM sum Wm�� 1W.TillLe 0=1 We , E, -- PunDiv-Pressure -T11 SI 11 M•. 1 • ■ .•.• 1 Koili1.11 Puct Sealing 1144(k) I Y I I I 1. For each chiller, cooling tower , boiler and hydronic loop (or group of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented . If a requirement is not applicable, put "NIA" in the column. 2. Water side systems include wet side systems using other liquids such as glycol or brine. 2005 Nonresidential Compliance Forms September 2005 =WATER SIDE SYSTEMS RE 10 I,,e !! NTS (Part2 of 3) MECH-2-C SERVICE HOT WATER & POOL REQUIREMENTS (Part 3 of 3) MECH-2-C PROJECT NAME DATE MADISON CLUB - RECEPTION BUILDING 02/2112006 i ITEM or SYSTEM TAG(S) Service Hot Water, Pool Heating MANDATORY MEASURES Se�c6on Reference on plans an specs. Water Heater Certification §113 (a) NIA Water Heater Efficiency § Service Water Heating Installation §113 (c) NIA Pool and Spa Efficiency and Control §114 (a) ' NIA Pool and -Spa Installation §114 (b) NIA Pool HeateNo Pilot Light §115 (c) NIA Spa Heater No Pilot Light §115 (d) NIA 1. For each hot water heater, pool heat and domestic water loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "NA" in the column. 2005 Nonresidential Compliance Forms September 2005 MECHANICAL VENTILATION AND REHEAT MECH-3-C (Part 1 of 1) PROJECT NAME MADISON CLUB - RECEPTION BUILDING K L M DATE 02/21/2006 A B C D B x 0 E F G H I A N/A AREA BASIS N/A OCCUP. BASIS REQ'D DESIGN SPACE COND CFM MIN SQ. FT./ NO. CFM MIN. O.A. SUPPLY ID AREA PER CFM OCCUPANT OF PER CFM MAX OF CFM A N/A SF BxC Tbl 4-2 PEOPLE PERSON (Ex15) D OR G N/A N/A Tbl 4-1 A N/A A N/A N/A N/A OFFICE #1 147 0.15 22 100 1 15 22 6 22 OFFICE #2 105 0.15 16 100 1 15 16 4 16 OFFICE #3 170 1 0.15 26 100 2 15 26 6 26 BREAK ROOM 111 0.15 17 100 1 15 17 4 17 MEN'S 74 0.15 11 100 1 11 11 1 3 11 OMEN'S 74 0.15 1 11 100 1 1 1 11 11 1 3 11 HALL 180 0.15 1 27 100 1 2 1 15 27 1 7 27 SALES ROOM 236 0.15 1 35 100 1 2 1 15 35 1 9 1 35 DISPLAY 579 1 0.15 1 87 1 100 1 6 1 15 1 87 1 22 1 87 WORKROOM 152 1 0.15 1 23 1 100 2 15 23 6 1 23 TOTALS 2185 1 1 328 22 328 82 328 REQUIRED OUTSIDE AIR - 82 CFM HVAC UNIT IS TO BE PROVIDED WITH MINIMUM OUTSIDE AIR PACKAGE (25%) HVAC UNIT IS TO BE PROVIDED WITH MINIMUM CFM = 328 REF TABLE 4-1A ON 4-17 Column I Total Design Ventilation Air C Minimum ventilation rate per Section §121, Table 121-A. EBased on fixed seat or the greater of the expected number of occupants an o or the cog occupant load r egress purposes for spaces without fixed seating. H Required Ventilation Air (REQ'D V.A.) is the larger of the ventilation rates calculated on an AREA BASIS or OCCUPANCY BASIS Column D or G). I Must be greater than or equal to H, or use Transfer Air (column N) to make up the difference. J Design fan supply cfm (Fan CFM) x 30%; or K Condition area (W) x 0.4 cfm/ft'; or L Maximum of Columns H, J, K, or 300 cfm M This must be less than or equal to Column L and greater than or equal to the sum of Columns H plus N. N Transfer Air must be provided where the Required Ventilation Air (Column H) is greater than the Design Minimum Air (Column M). Where required, transfer air must be greater than or equal to the difference between 2006 Nonresidential Compliance Forms September 2005 MECH-3-C VAV Mlnlmum K L M N 0 P RSFR AIR ° of Design guppy supply cfm B x 0 Max of Design Column minimum ora 0' Air cfm setpoint Transfer Air N/A A N/A N/A N/A N/A N/A N/A N/A N/A A N/A N/A N/A N/A A N/A N/A N/A N/A A N/A N/A N/A N/A *N/AN/A N/A N/A N/A A N/A N/A N/A N/A A N/A N/A N/A N/A A N/A N/A N/A N/A A N/A N/A N/A N/A NIA. N/A N/A CERTIFICATE OF COMPLIANCE ' - - ' (Part 1 of 4) LTG -1 -C PROJECT NAME MADISON CLUB -RECEPTION CENTER DATE 1 02/03/2006 PROJECT ADDRESS LA QUINTA, CALIFORNIA LTG -1-C, Parts 3 of 4 PRINCIPAL DESIGNER -LIGHTING TELEPHONE Building Permit it DOCUMENTATION AUTHOR DREAM ENGINEERING INC. TELEPHONE (909)475-9900] Checked by/Date Enforcement Agency Use GENERAL INFORMATION ® DATE OF PLANS 02/0312006 BUILDING CONDITIONED FLOOR AREA 2,185 SQ. FT. CLIMATE ZONE 15 BUILDING TYPE ® NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEUMOTEL GUEST" ® CONDITIONED SPACES ❑ UNCONDITIONED SPACES ❑ INDOOR/OUTDOOR SIGNS ® PHASE OF CONSTRUCTION ® NEW ❑ ADDITION ❑ ALTERATION Interior Lighting Power Allowance METHOD OF LIGHTING COMPLIANCE ® PERFORMANCE ❑ COMPLETE BLDG. ❑ AREA CATEGORY ❑ TAILORED ❑ COMMON LIGHTING STATEMENT OF COMPLIANCE ❑ This Certificate of Compliance lists the building features and performance specifications need to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. JOSEPH M. NOLAN SEP. 30, 2007 The Principal Lighting Designer hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in the applicable parts of Sections 110, 119, 130 through 132, 146, and 149 of Title 24, Part 6. ® The plans & specifications meet the requirements of Part 6 (sections 10-103a). ❑ The installation certificates meet the requirements of Part 6 (10-103a 3). ❑ The operation & maintenance information meet the requirements of Part 6 (10-103c). Please check one: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ® 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. ❑ I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ I affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. PRINCIPAL LIGHTING DESIGNERS NAME IG UR DATE LIC.JI JOSEPH M. NOLAN SEP. 30, 2007 E.E. - 9333 LIGHTING MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures E5 LIGHTING COMLIANCE FORMS & WORKSHEETS (check box if worksheet is included) ® LTG -1-C, Parts 1 of 4 and 2 of 4 Certificate of Compliance. Part 1 of 4 and 2 of 4 are required for all submittals ® LTG -1-C, Parts 3 of 4 Certificate of Compliance. Part 3 of 4 submittal is required only if Control Credit are claimed ❑ LTG -1-C, Parts 4 of 4 Certificate of Compliance. Part 4 of 4 submittal is required when lighting controls are installed ® LTG -2-C Interior Lighting Schedule ® LTG -3-C, Portable Lighting Worksheet ❑ LTG -4-C Lighting Controls Credit Worksheet ® LTG -5-C Interior Lighting Power Allowance ❑ LTG -6-C Tailored Method Worksheet ❑ LTG -7-C Room Cavity Ratio Worksheet ❑ LTG -8-C Common Lighting Systems Method Worksheet ❑ LTG -9-C Line Voltage Track Lighting Worksheet ❑ OLTG-4-C Signs (See OLTG-4-C Sign Worksheet in Ch. 6, Outdoor Lighting and Signs Chapter) 2005 Nonresidential Compliance Forms . April 2005 CERTIFICATE OF COMPLIANCE (Part 2 of 4) LTG -1:-C MADISON CLUB - RECEPTION CENTER 0210312006 INSTALLED INTERIOR LIGHTING POWER FOR CONDITIONED AND UNCONDITIOED SPACES ALLOWED INTERIOR LIGHTING POWER FOR CONDITIOED SPACES ® COMPLETE BUILDING METHOD (from LTG -5-C) ❑ AREA CATEGORY METHOD (from LTG -5-C) ❑ TAILORED METHOD (from LTG -5-C) ALLOWED WATTS ADJUSTED LIGHTING POWER 2404 1 ALTERNATE COMPLIANCE 1 ❑ PERFORMANCE METHOD ❑ COMMON LIGHTING SYSTEM (from LTG -8-C) ALLOWED INTERIOR LIGHTING POWER FOR UNCONDITIONED SPACES (from LTG -5-C) Watts MANDATORY LIGHTING MEASURES FOR INTERIOR AND DAYLIT AREAS INSTALLED WATTS INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) 2404 PORTABLE LIGHTING (From LTG -3-C) -0- LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG -4C) -0- CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 2404 INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) -0- LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4C) -0- UNCONDITIONED SPACE ADJUSTED LIGHTING POWER -0- ALLOWED INTERIOR LIGHTING POWER FOR CONDITIOED SPACES ® COMPLETE BUILDING METHOD (from LTG -5-C) ❑ AREA CATEGORY METHOD (from LTG -5-C) ❑ TAILORED METHOD (from LTG -5-C) ALLOWED WATTS ADJUSTED LIGHTING POWER 2404 1 ALTERNATE COMPLIANCE 1 ❑ PERFORMANCE METHOD ❑ COMMON LIGHTING SYSTEM (from LTG -8-C) ALLOWED INTERIOR LIGHTING POWER FOR UNCONDITIONED SPACES (from LTG -5-C) Watts MANDATORY LIGHTING MEASURES FOR INTERIOR AND DAYLIT AREAS CONTROL LOCATION (Room #, Area #, or Description) CONTROL INDENTIFICATION CONTROL TYPE (Auto Time Switch, Dimming, Photosensor, Etc) SPACE CONTROLLED Lists the location of controlled lights If Control is for Daylighting NOTE TO FIELD 2005 Nonresidential Compliance Forms April 2005 CERTIFICATE OF COMPLIANCE (Part 3 of 4) LTG -1 -C PROJECT NAME DATE MADISON CLUB - RECEPTION CENTER 10210312006 CONTROL FOR CREDIT IN CONDITIONED AND UNCONDITIONED SPACES CONTROL TYPE SPACE CONTROLLED If Control is CONTROL LOCATION (Auto Time Switch, Lists the location of for NOTE TO (Room #, Area #, or CONTROL Dimming, controlled lights Daylighting FIELD Description) INDENTIFICATION Photosensor, Etc) 2005 Nonresidential Compliance Forms April 2005 INTERIOR LIGHTING SCHEDULE (Part 1 of 2) LTG -2-C PROJECT NAME MADISON CLUB - RECEPTION CENTER 7DATE 3/2006 INSTALLED LIGHTING POWER FOR CONDITIOED SPACES Luminaire Camps/Ballasts Installed Watts A B C D E F G H I J - Name Type Decription �y M r z 333 7 1A�0 t r °° z 3;v3 r c z A CEILING MOUNT INCAND 3 574 B CEILING MOUNT INCAND 12 1699 C WALL MOUNTED INCAND 4 128 PAGE TOTAL BUILDING TOTAL (sum of all pages) PORTABLE LIGHTING (from LTG -3-C) CONTROL CREDIT (from LTG -4-C) ADJUSTED ACTUAL WATTS 2401 2401 -0- -0- 2401 2005 Nonresidential Compliance Forms April 2005 PORTABLE LIGHTING WORKSHEET LTG -3-C PROJECT NAME, MADISON CLUB - RECEPTION CENTER DATE 0210312006 TABLE 1A - PORTABLE LIGHTING NOT SHOWN ON PLANS FOR OFFICE AREA > 250 SQUARE FEET A B C D ROOM # OR ZONE ID AREA TOTAL WATTS DEFAULT (WATTS) (SF) (BxC) 0.2 0.2 0.2 0.2 0.2 0.2 TOTAL TABLE 2 - PORTABLE LIGHTING SHOWN ON PLANS FOR OFFICE AREA > 250 SQUARE FEET A B C D E F G ROOM # OR ZONE ID PORTABLE LIGHTING DESCRIPTION (S) PER TASK AREA LUMINAIRES (S) WATTS PER TASK AREA TASK AREA (SF) NUMBER OF TASK AREAS (SF) (DxE) TOTAL WATTS (CxE) N/A TOTAL TABLE 3 - PLANS SHOW PORTABLE LIGHTING IS NOT REQUIRED FOR OFFICE AREAS > 250 SQUARE FEET ROOM # TOTAL AREA OR ZONE ID SF Designer need to provide detailed documentation that the lighting level provided by the overhead lighting meets the needs of the space. the details include luminaire types, CU, and mounting locations relative to work areas. TOTAL BUILDING SUMMARY - PORTABLE LIGHTING BUILDING SUMMARY TOTALAREA (SF) (FROM TABLES 1A+1 B+1C) TOTAL WATTS (FROM TABLES 1A+1 B) BUILDING TOTAL N/A Enter on LTG -1 and 2: Portable Lighting 2005 Nonresidential Compliance Forms April 2005 INTERIOR LIGHTING POWER ALLOWANCE LTG -5-C MADISON CLUB - RECEPTION CENTER 10210312006 ALLOWED LIGHTING POWER (Choose One Method) ICOMPLETE BUILDING METHOD -I BUILDING CATEGORY (From § 146 Table 146-B) WATTS COMPLETEALLOWED C D PER SF BLDG. AREA WATTS L OFFICE AREA 1.1 2185 2404 AREA CATEGORY METHOD - CONDITIONED SPACES A B C D AREA CATEGORY (From § 146 Table 146-C) WATTS PER SF AREA (SF) ALLOWED WATTS TOTALS AREA WATTS TAILORED METHOD TOTAL ALLOWED WATTS (From LTG -6-C) UNCONDITIONED SPACES A B C D Complete Building and Area Category Methods CATEGORY (From § 146 Table 146-B & C) WATTS PER SF AREA (SF) ALLOWED WATTS TOTALS AREA WATTS TAILORED METHOD - UNCONDITIONED SPACES TOTAL UNCONDITIONED SPACES ALLOWED WATTS (From LTG -5-C and LTG -6-C) 2005 Nonresidential Compliance Forms April 2005 k MANDATORY MEASURES LIGHTING' Building Lighting Shut-off The building lighting shut—off system consists of an automatic time switch, with a zone for each floor: or the building is separately metered and less than 5,000 square feet; exempt from the shut—off requirement Override for Building Lighting Shut-off The automatic building shut—off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 sf. Automatic Control Devices Certified All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. - Daylit Area Control All rooms with windows and skylights, that are greater than 250 square feet, and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylight area controlled by a separate switch; The effective use of daylight through , cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of year' is included on plans. Individual Room/Area. Controls Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor—to—ceiling walls. Control of Exterior Lights Exterior mounted fixtures and served from the electrical panel inside the building are controlled with a directional photo cell control on the roof and a corresponding reloy-in the electrical panel. Tandem Wiring for Two -Lamp Ballast's All one and three lamp fluorescent fixtures are tandem wired with two (2) lamp ballast where required by Standards Section 132; or all three lamp fluorescent fixtures are specified with electronic high—frequency ballast's and are exempt from two—lamp tandem wiring requirements. Fluorescent Ballast and Luminaries Certified. All fluorescent fixtures specified for the project. are certified and listed in the 'Directory. All installed fixtures shall be certified. Uniform Reductio_ n for Individual Rooms All rooms and area greater than 100 square feet and more than 1.2 watts per square foot of lighting load shall be controlled with Bi— level switching for uniform reduction of lighting within the room. 4 CLRTIFICATE OF COMPLIANCE (Part 1 of 2) OLTG-1-C PROJECT NAME MADISON CLUB - RECEPTION BUILDING DATE 02/03/2006 PROJECT ADDRESS LA QUINTA, CA 1. Use LTG -1-C if the project consists solely of indoor signs Building Permit # Checked by/Date Enforcement Agency Use PRINCIPAL DESIGNER -LIGHTING TELEPHONE DOCUMENTATION AUTHOR DREAM ENGINEERING INC. TELEPHONE (909) 4759900 GENERAL INFORMATION 4. Use OLTG-I-C if the project consists of outdoor lighting, and indoor or outdoor signs, DATE OF PLANS 06129/05 OUTDOOR LIGHTING ZONE ❑ LZ1 ® LZ2 ❑ LZ3 ❑ LZ4 FUNCTION TYPE ® OUTDOOR LIGHTING ❑ OUTDOOR SIGNS ❑ INDOOR SIGNS PHASE OF CONSTRUCTION ® NEW CONSTRUCTION 0 ADDITION ❑ ALTERATION STATEMENT OF COMPLIANCE signs, for both indoor and outdoor signs. This Certificate of Compliance lists outdoor lighting system specifications need to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements. The documentation prepare hereby certifies that the documentation is accurate and complete. DOCUMENTATION Al JOSEPH M. NOLAN I ""#A 07/ 1* --r-- I SEP. 30, 2007 The Principal Lighting Designer hereby certifies that the proposed buildin Ign represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in the applicable parts of Sections 110, 119, 130 through 132, 146, and 149 of Title 24, Part 6. ® I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. ❑ I affirm that 1 am eligible under the provisions of Division 3 of the Business and Professions Code by section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work ❑ I affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. PRINCIPAL LIGHTING DESIGNERS NAME SIGNATURE DATE LIC. # JOSEPH M. NOLAN ognnSEP. 30, 2007 E.E. - 9333 INSTRUCTIONS TO APPLICANT OUTDOOR LIGHTING COMPLIANCE & WORKSHEETS For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the Nonresidential Manual published by the California Energy Commission. ® LTG -1-C, Parts 1 of 4 and 2 of 4 Certificate of Compliance. Required on plans for all submittals for outdoor lighting. Part 2 of 2 may be incorporated in schedules on plans. Either LTG -1-C or OLTG-I-C may be used for signs as follows: 1. Use LTG -1-C if the project consists solely of indoor signs 2. Use LTG -1-C if the project consists of indoor lighting, and outdoor or indoor signs, but no other outdoor lighting 3. Use OLTG-I-C if the project consists soly of outdoor signs 4. Use OLTG-I-C if the project consists of outdoor lighting, and indoor or outdoor signs, but no other indoor lighting ® OLTG-2-C LIGHTING COMPLIANCE SUMMARY. Applicable Parts required for ALL outdoor lighting allowances (Except for Signs) ® OLTG-3-C AREA CALCULATIONS WORKSHEETS. Applicable parts required for all outdoor area calculations. ❑ OLTG-4-C SIGN LIGHTING COMPLIANCE. Required for all internally and externally illuminated signs, for both indoor and outdoor signs. 2005 Nonresidential Compliance Forms April 2005 CtRTIFICATE OF COMPLIANCE , .• - (Part 2 of 2) OLTG-1-C MADISON CLUB - RECEPTION BUILDING 02/032006 Lighting Schedules on Plans Show that Outdoor Lighting Meets Allowed Lighting Power ® Lighting power allowances for general site illumination on OLTG2-C Part 1 of 4 ❑ Not Applicable ❑ Lighting power allowances for local ordinances or for security multipliers on OLTG-2-C Part 2 of 4 ® Not Applicable - ❑ Lighting power allowances for specific applications, other than vehicles service stations with canopies on OLTG2-C Part 3 of 4 ® Not Applicable ❑ Lighting power allowances for vehicles service'station canopies on OLTG2-C Part 4 of 4 ® Not Applicable ❑ Sign lighting compliance on OLTC-4-C ® Not Applicable Mandatory Measures on Plans Show that Outdoor Lighting Meets Outdoor Lighting Controls and Equipment Indicated location on plans of Note Block for Mandatory Measures ® Installed lighting power has been determined in accordance with ,%130(c)1 ❑ Not Applicable ❑ All permanently installed luminaires with lamps rated over 100 watts either have a lamp efficacy of at least 60 lumens per waft or are controlled. by a motion sensor § 132(a) ® Not Applicable ❑ All luminaires with lamps rated greater than 175 watts in hardscape areas, including parking lots, building entrances, canopies, and all outdoor sales areas meet the Cutoff Requirements of %132(b) ® Not Applicable ® All permanently installed outdoor lighting meets the Control Requirements of§ 132(c)l ❑ Not Applicable ® Building facades, parking lots, garages, canopies, and outdoor sales areas meet the Mufti -Level Lighting Requirements of S432(c)2 ❑ Not Applicable MANDATORY LIGHTING MEASURES FOR INTERIOR AND DAYLIT AREAS CONTROL LOCATION CONTROL IDENTIFICATION CONTROLTYPE (Auto Time SwitchC photosensor, Etc) AREA CONTROLLED NOTE TO FIELD N/A 2005 Nonresidential Compliance Fom►s A April 2005 r LIGHTING COMPLIANCE SUMMARY (Part 1 of 4) OLTG-2-C PROJECT NAME DATE MADISON CLUB - RECEPTION BUILDING 02/03/2006 LIGHTING POWER ALLOWANCES - GENERAL SITE ILLUMINATION - (Table 147-A) LIGHTING AREA ALLOYED I ALLOTED I CODE_ D_E_55_C_R_IPTION CUTOFF LAMP #OF LUMINARE CEC #OF INSTALLED 184 _ —APPLICATION I INCAND LPD WATTS ETTE 182 DESIGN TYPE LAMPS WATT BALLAST WATTS I DEFAULT LUMINAIRES I WATTS WALL MOUNTED B C D E . _F .. G H I_ I J _ �� _ le___ L M N 28 PARKING LOT 8465 0.08 677 E SHOE BOXM/H FULL M/H 1 200 1 1 233 2 465 SOUTH ENTRANCE (CANOPY) 736 0.25 184 F I INCAND FULL INCAND x 3 182 NORTH ENTRANCE 54 0.50 27 G WALL MOUNTED FULL CFL x 2 28 NORTH CANOPIED SPACE 135 0.25 34 H INCAND FULL INCAND x 1 28 TOTAL ALLOTED WATTS 822TOTAL INSTALLED WATTS 703 ner. vucaoor ugnung Ona signs - �aenerai sad wum inOavn Table 63 -Standards Table 147-A General Site Blum Inatlon LPDValues 12005 Nonresidential Compliance Forms April 2005 REQUIREMENTS FOR OUTDOOR LIGHTING 1 SECTION 147. REQUIREAIENTS FOR OUTLIOORLIGNTING This section applies to all outdoor lighting, whether attached to buildings, poles, structures or sell supporting, Including but not fimited to, hardscape areas Including parking Ids, lighting for bulli ing entrances, sales and non -sales canopies; lighting for all outdoor sales areas; and lighting for building facades. EXCEPTIONS to Section 147: 1. Temporary outdoor lighting. 2. Lighting required and regulated by the Federal Aviation Administration, and the Coast Guard. 3. Lighting for public streets, roadways, highways, and traffic signage lighting, Including lighting for driveway entrances occurring In the public tight -of -way. 4. Lighting for spoils and athletic fields, and children's playground. 5. Lighting for Industrial sites, Including but not limited to, mall yards, maritime shipyards and docks, piers and marinas, chemical and petroleum processing plants, and aviation facilities. 6. Automated Teller Machine fighting, 7. Lighting of public monuments. B. Internally Illuminated, externally Illuminated, and unfiltered signs. 6. Lighting used In or around Swimming Dods, water features, or other locations subject to Article 680 of the California Electrical Code. 10. Lighting of tunnels, bridges, stairs, and ramps. 11. Landscape lighting. (a) Outdoor Lighting Power. An outdoor lighting Installation compiles with this section if the actual outdoor lighting power calculated under Subsection (b ) IS no greater then the allowed artdoor fighting power calculated under Subsection (c ). The allowed outdoor fighting shag be calculated by Lighting Zone as defined In Section 10.114. Local governments may amend lighting zones In ccrrpilance with Section 10.114. Trading off fighting power allowances with any Indoor areas shall not be permitted. (b) Calculation of Actual Lighting Power. The actual Ilghling power of outdoor lighting Is the Idol watts of all fighting systems (Including ballast or transformer loss). (c) Calculation of Allowed Ughting Power. The allowed lighting power shall be calculated as follows: 1. Determine the allowed fighting power for general Illumination of the she as follows: A. In plan New of the site, determine the illuminated area. The hWmineted area Is defined as any area within a square pattern around each luminalre or pole that Is six tines the luminalre mounting height, with the lumtnalre In the middle of the pattern, less any area that Is within a Willing, under a canopy, beyond property lines, or obstructed by a sign or structure. S. Determine a lighting application from Table 147-4 for each potion of the Illuminated area. Determine the allowed area for each application. Note that the allowed area only applies to Illuminated areas. Only portions of the she that are Inside the illuminated area determined In step A qualify for allowed lighting power for general Illumination. Multiply the allowed area of each lighting application by the Showed lighting paver density from Table 147-A Only applications listed In Table 147-A shall be Included. Each portion of the Illuminated area shall only be assigned one lighting application, and the assigned lighting applications shah be consistent with the actual use of the area. The allowed area of a she roadway, driveway, sidewalk, walkway or bikeway shell be determined by either of the following methods. I. The actual paved area plus 5 feet an either side of the centerline path of travel; or 11. A 25 foot wide area running along the axis of the path of travel and Including as much of the paved area of the site roadway, driveway, sidewalk, walkway or bikeway as possible. Any overlapping area of another fighting application shag be subtracted from the area of the other lighting application. In this case the allowed lighting power Is the length of the centerline of the path times the allowed power per unit length. EXCEPTION 1 to Section 147 (c)1 B: For hardscape Including parking lots, site roadways, driveways, sidewalks, walkways or bikeways, when specific light levels are required by law through a local ordinance, the Shaved lighting power densities specified In TABLE 147-C may be used to calculate the allowed lighting power. EXCEPTION 2 to Section 147 (c)1 S: For retell parking Ids In lighting zones 1, 2, end 3, hardscape areas within 100 feet of the entrance of senior housing facilities, and parking lots and walkways within 60 feet of building entrances for law enforcement, fire, ambulance and emergency vehicle facilities, the allowed lighting power densities specified In Table 147-A may be adjusted by applying the multipliers for special security requirements In TABLE 147-D to establish allowed lighting paver for these special applications. Lundnalres qualifying for these adjusted allowances shall not be used to determine allowed power for general Illumination. The adjusted lighting power allowances shall be separate allotments, which shag be compiled with separately without tradeoffs. 2. Determine the allowed fighting power for specific applications as follows: A. Determine the allowed fighting power for building fagade. The allowed lighting power for fighting the facade shall be the smaller of the product of the area of the fagade and the allowed lighting power density for it from Table 147.8, or the actual power used to Illuminate the facade. Only areas of the fagade that are Illuminated without obstruction or interference, by one or more luminaires, shag be used. Luminaires qualifying far this allowance shag not be used to determine allowed fighting power for general Ihulninatlan. B. Detemdne the allowed lighting power for outdoor sales frontage. The allowed fighting power for outdoor sales frontage shall be the smaller of the product oflhe frontage (in feet) and the Showed lighting power density per foot from Table 147-B, or the actual power used to Illuminate the frontage. Sales frontage shag be Immediately adjacent to the principal viewing location and unobstructed for es viewing length. A comer sales Id may include both sides provided that a different principal viewing location exists for each side. Measured In plan view, only sections ortthe outdoor sales area that are along the frontage and are withIn e 3 mounting heights of frontage luminaires shell be eligible for this power allowence. Luminaires qualifying for this allowance shell be located In plan New between the principal viewing location and the frontage outdoor sales area, and shag not be used to determine allowed lighting power for general Illumination. C. Determine the allowed lighting power for ornamental fighting. The allowed lighting power for ornamental lighting shall be the smaller of the product of the total area of the site external to bulldings, and the allowed lighting power density for ornamental lighting from Table 147-B, or the actual power used for ornamental lighting. Luminaires qualifying for this allowance shell employ lamps rated 100 watts or less, and shag not be used to determine allowed lighting power for general Numlnatlen. D. Determine the allowed fighting paver for fighting under canopies. The allowed "Ing power for lighting under a canopy shell be the smaller of the product of the area In plan New of the horizontal projection of the canopy and the allowed lighting power density for either a vehicle service station with or without canopies, for all other sales canopies, or for non -sales canopies from Table 147.8 or the actual power used for lighting mounted beneath the canopy. Luminaires qualifying for this allowance shah not be used to determine allowed Ilghting power for general illumination. E. Determine the allowed Aghting power for fighting of vehicle service stations without canopies. The Showed lighting power for an uncovered a service station without canopy shag be the Smaller otthe product of the allowed Ilghting power densly for a vehicle service station with or without canopies and 500 square feat per double-slded fuel dispenser, or the actual power used to Illuminate this area (In cases where the site only allows fuel to be dispensed on one side of the dispenser, the allowed lighting paver shall be the smaller of the product of the allowed lighting power density and 250 square feet per dispenser or the actual power). Luminaires qualifying for this allowance shag not be used to determine allowed fighting power for general Illumination. F. Deternlne the allowed lighting power for lighting of vehicle service station hardscape areas. The allowed lighting power for vehicle service station hardscape areas shah be the smaller of the product of the area of the vehicle Sellae station hardseepe and the allowed lighting power densly foot frau Table 147-8, or the actual paver used to gluminate this area. Vehicle service Station hardscape areas Include all vehicle service station outdoor hardscape areas beyond the horizontal projection of the canopy In plan view. Luminaires qualifying for this allowance shall not be used to determine slowed lighting power for general illumination. G. Determine the allowed lighting paver for drlve-up windows. The slaved lighting power for drive -up windows shall be the smaller of the product of the area ofthe drive -up window and the allowed lighting power density foot from Table 147-B, or the actual power used to Illuminate this area. Drhe-up window area is the product of the width of the window plus sin feet and the distance 30 feet outward from the window. Luminaires qualifying for this allowance shell not be used to determine slowed lighting power for general Illumination. H. Determine the allowed fighting parer for guarded facilities. The allowed sighting power for guarded facilities shall be the smeller of the product of the area for the guarded facility and the allowed fighting power densities specified In Tablas 147-B. The guarded facility area Includes the guardhouse Interior area plug the product of the entrance width of 25 feet and length of 80 feet. Guarded facilities Include the entrance driveway, getahouse, and guardhouse Interior areas that provide access to secure areas controlled by security personnel who slap and may Inspect vehicles and vehicle occupants Including, Identification documentation, vehicle license plates, and vehicle contents. Luminaires qualifying for this allowance shag not be used to determine Showed fighting power for general Illumination. I. Determine the allowed fighting power for outdoor dining. The allowed lighting power for outdoor dining shag be the smaller of the product of the outdoor dining area and the allowed lighting power density from Table 147- 6, or the actual power used to illuminate this area. Outdoor dining areas are hardscape areas used to serve and consume food and beverages. Luminaires qualifying for this allowance shell not be used to determine allowed lighting power for general Illumination. 3. The Ahmed Lighting Power shall be the total of the allowed power for general illumination of the site as determined In Section 147 (c) 1 C and the sum of all the allowed power for specific applications determined under Section 147 (c) 2. The shaved outdoor power and the Showed Indoor power determined In Section 146 (b) shag be separate allotments, which shall be met separately without tradeoffs between the separate allotments. OTHERKISENOTED) Lighting Application Alowwd Area Lghlhg Zone I. Lghlhg Ione 2. Lgtohg Zama 3. Lighting Zama 1. Horoscope for eutomo0ve venecular use, hcudhg pending bit wmyt all ale made Method p.) Actual paved ams pan 6' perimeter of tipcem unpaved lend. Incudes pence. and landscaped areas Nee then 10 wile that m encloud by hamscaps on at best tore ones.. 0.00 0.08 0.15 0.19 Hmacape for pedestrian use, hcudibg, PkUal. akeewaks, Mammal a and bkewl" Method p.)Adual paved ama pm 5 feet of unpaved lend on ether likes of path of trawl. Shot bode at comhuous paved me bemre Including adjacent grounds. 028 0.09 0,17 0.21 Hmscape for dnvewayl, see made, sidewalks, wekweye and bksvmys Method (l.) 26' wide path licorpomthg as much of the paved ams, crime file reuway, dMwAy. uleweR, wady or bl smay a potatoes. 12 wR 1.5 *1 4.0 wit 6.0 of Building Eminences "howl campy) WyOh of doom Pon 3 e on ether akeetime a distance of is met cul ard. 0.360.50.701.00 Outdoor Saba Lol Actual portion of unsowted oddaor .aide let used excels Imly for display of vehicles or other memhadba for sale. At ayoam access drives, wakway emu, custom orpor" ensu, vehicle tents or storage ones that am mat surrounded on at mast three aides by title was shot be considered hardscape. 0.36 0.701.25 2.00 TABLE 147.8 LIONTINO POMRALLOWANCES FOR SPECIFIC APPLICATIONS (WIM UNLESS OTNERAMSE NOTED) Lighting Applitatbn Lighting Zone 1 Iugmhp Zone 2 Lighting Zone 3 Ligmihg Zone 4 Buldhmg Facades Not slowed 0.19 0.35 0.60 Outdoor gales Fromaps ffmmege In auermsg Not aumd 222 wr 36.5 wR 55 wR Vertices SeMce Stettin won a w5hout Camplas 0.701.15, AS 2,40 vehicle SeMcs Station Handicaps, 0.05 020 0,400.60 Al Otirer Saba Wailes Not allowed 0.70 1.00 1.25 Nonaaba canoplss 0.12 0.25 0.60 0.70 Ommemal Lighting Not a0ewed 0,01 0.02 0.04 011e W uwndaws 0.12 0.25 0.50 0.70 Guarded Fsctlesa 0.19 LA0 0.80 1.10 custom Dhhg 0.06 0.15 025 0.55 200.1 BuRBrp Emagy Eetacy Stenduds Pope 117 TABLE 147.0 ALTERN477VE POWER ALLOWANCE FOR ORDIAKACE REQUIREMENTS Required rant levels by lox through a local emitters: a(horkmel rook mines, everege) Allowed Lipmhp Power Density (vwn2) 0.5 0.05 1.0 0.07 140.10 22 0.12 3.0 0.19 4.0 or greater 0.25 TABLE 147-0 NIULDPLIERS FOR SPECIAL SECLIM REQt4RENENTS Function kulpher Relal parking Ion In ghmg zones 1, 2 and 3125 Hamscape area. %thin 100 met or the entrance of senbrbouMg income In fighting one. 1, 2, and 3125 Par" lots and wakways W hh 60 fast of emnerces to the building for law emorce-rd, m, ambulance and emergency vehicle facilities 2.00 ILLUMINATED AREA CALCULATION WORKSHEET (Part 1 of 5) OLTG-3-C PROJECT NAME MADISON CLUB - RECEPTION BUILDING 102/03/2006 DATE Hardscapre - Method (() A. Hardscape for automotive vehicular use, Including parking lots, driveways and site roads A B C D E F G H List Specific p Application ( Table 147-A) Actual Paved Area plus 5' perimeter of adjacent unpaved land. Includes planters and landscaped areas less than 10' wide that are enclosed by hardsca a on at least 3 p sides Areas (ft2) to Subtract from within Illuminated Area Areas between poles luminairesthat are greater than 8 mounting height distances (IP Appllcatable) Overlapping Areas of Another Application or Luminaire Building Areas Areas Obstructed By Signor Other Structure Sub Total of areas to Subtract (C + D + E + F) Illuminated Area (B - G) B. Hardscapre for pedestrian use, including plazas, sidewalks, walkways and bikeways A B C D E F G H List Specific Application ( Table 147-A) Actual Paved Area plus 6' perimeter of adjacent unpaved land. Includes planters and landscaped areas less than 10' wide that are enclosed by hardscape on at least 3 sides Areas (ft2) to Subtract from within Illuminated Area Areas between poles or luminaires that are greater than 6 mounting height distances (If Applicatable) Overlapping Areas of Another Application or Luminalre Building Areas Areas Obstructed By Sign or Other Structure Sub Total of areas to' Subtract (C + D + E + F) Illuminated Area (S - G) Checklist ® § 147(c)l B - Each portion of all illuminated areas has been assigned only one lighting application, and the applications are consistent with the actual use of the areas. ® § 147(c)l A - General illumination areas includes only those illuminated areas that are in the bounds of the Application and are within a square pattern around a luminaire that is six times the luminaire mounting height, with the luminaire in the middle of.the pattern, less any areas that are within buildings, under canopies, beyond property lines, or obstructed by a signs or other structures 2005 Nonresidential Compliance Forms April 2005 9 Bin # ' C - City of La Quetta Building U Safety Division P.O. Box 1504, 787495 Calle Tampico, La Quinta, CA 92253 - (760) 777-7012 • _ Building Permit Application and Tracking Sheet:` iu erinit # Project Address: 5-2— ©�� /J�Q�I���� Owner's Name. ., G/ A. P. Number: Address: Legal Description: %.a Z 5'�Q76 �. City, ST, Zip: Contractor: `��r v Telephone; Address: • Project Description: ` City, ST, Zip: X22 /WTelephone: .•.• #Q�_ / r State Lic. # : City Lic. #: Arch., Engr., Designer: �� L Address: City, ST, Zip: Telephone: -. , Construction Type:.- Occupancy: . State Lic.'#: Project type (circle one): New . Add'nAlter Repair Demo Name of Contact Person: Sq. Ft.: # Stories: #Units: 1e4L Telephone # of Contact Person: `�� Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal ' • Req'd Recd , TRACKING PERMIT FEES ' Plan Sets Plan Check submitted t Item Amount Structural Calcs. Reviewed, ready for corrections Z� Plan Check Deposit Truss Calcs. Called Contact Person i Plan Check Balance Energy Calcs. Plans picked up /1 Construction e Flood plain plan. Plans resubmitted Mechanical Oft Grading. plan 2°" Review, ready for orrections sue Electrical Subcontactor. List Called Contact Person L'L� Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval/10Plans resubmitted' 7� Grading IN HOUSE:- ''" Review, ready for correction /issue * Developer Impact Fee ' Planning Approval Called Contact Person LV Pub. Wks. Appr Date of pe it issue u O School Fees Total Permit Fees UVp Gt;v f�'p