Loading...
CONR (05-3825)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number:\0.5-12_00`003825 5 Property Address: 2-0—MERIWETHER WY APN: 767-200-998-81 -330761- Application description: NEW COMML - OTHER NON-RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 28382 T4ht* 4 4 a" BUILDING & SAFETY DEPARTMENT .BUILDING PERMIT Applicant: Architect or Engineer: _VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/18/06 Owner: EAST OF MADISON LLC .PO BOX 1482 aLA QUINTA, CA 92247 U - f pk t* Contractor: ir LUSARDI CONSTRUCTION COMPANY .1570 LINDA VISTA DRIVE SAN MARCOS, CA 92078 (760)744-3133 LiC. No.: 207287 ---------------------7---------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed.under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: A B License No.: 207287 ate: �/n Contractor: —� OWNER -BUILDER DECLARATION hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to. construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and 1100, the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ' (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I—) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT --------------- - - - WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued: My workers' compensation insurance carrier and policy number are: Carrier NATL FIRE INS Policy Number WC7169394 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation. provisions of Section 3700 of t>heILabor Code, I shall forthwith comply with those provisions. o0fate S �� v4 plicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR•CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for ' whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quints, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days -from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I. certify that I have read this application and state that the above information is correct. I agree to comply with all city an unty ordinances and state laws relating to building construction, and hereby authorize representatives of_tW county too«l �•G enter upon the above-mentioned property for inspection purposes. Dater Si tura (Applicant or Agent): ' l LQPERMIT Application Number 05-00003825 Permit . .. BUILDING PERMIT - Additional desc . Permit Fee 278.00 Plan Check Fee '180:70 Issue Date . . . Valuation . . . 28382 Expiration Date 11/14/.06 Qty Unit Charge Per Extension BASE FEE 252.00. 4.00 6.5000 THOU BLDG 25,001-50,000 26.00 Permit MECHANICAL Additional desc . Permit Fee. . 30.50 Plan Check Fee 7.63 Issue Date Valuation 0 Expiration Date .11/14/06 Qty Unit Charge Per -Ex tension BASE FEE 15.00• 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 6.5000 EA MECH VENT FAN' 6.50 Permit' ELEC-NEW COMMERCIAL Additional desc .. Permit Fee . . . . 24..72 Plan Check Fee 6.18 _ Issue Date .. . . . Valuation . . . . 0 _ Expiration Date 11/14/06 Qty Unit Charge Per Extension BASE FEE 15.00 486.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 9.72 . Permit PLUMBING Additional desc . Permit Fee 73.50 Plan Check Fee 18.38 Issue Date Valuation . . . . 0 Expiration'Date. 11/14/06. Qty Unit.Charge" 'Per Extension BASE FEE 15.00 3..00 6.0000 EA PLB.FIXTURE 18.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00. 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 1.00 15.0000 EA PLB GAS METER 15.00 l LQPERMIT Application Number 05-00003825 Permit . . . GRADING PERMIT Additional desc . Permit Fee. 15.00. Plan .Check 'Fee 00 r Issue Date Valuation 0 •Expiration Date 11/14%06 Qty Unit Charge Per Extension BASE FEE 15.00 -------------------------------------- 7 -------------------------------------- Special Notes and Comments GUARDHOUSE °B" 486 SF.B OCCUPANCY, TYPE V -N CONSTRUCTION, 2001 CBC, CMC, CPC.2004 CEC, 2005 ENERGY CODES. Other Fees ACCESSIBILITY PLAN REVIEW 18.07 ART IN PUBLIC PLACES -COM 121.91 DIF CIVIC CENTER - COMM 26.24 ENERGY REVIEW FEE 18.07 DIF FIRE PROTECTION -COMM- 28.18. STRONG MOTION (SMI).- COM 5.96. DIF STREET MAINT FAC -COMM 13.60 DIF TRANSPORTATION COMM .1028.37 Fee summary, Charged Paid Credited Due --------------------------- ---------- - Permit Fee Total 421.72 .00 .00 421.72" Plan Check Total, 212.89 150.00 00 62.89 Other Fee Total 1260.40: ..00 .00 1260:40 Grand Total 1895.01" 150.00 .00 1745.01 LQPERMIT r Co- 07,6e C -k 44 Po. BOX 1504 APPLICATIO ONL Building 78-495 CALLE TAMPICO AddFess LA QUINTA, CALIFORNIA 92253 / Owner Mailing Address ,f . V- ,65)z /LIlg2 CityZi Tel. aim L;ontractor Address City �Z!�! ZC-Qa//1 7� State Lic. CiTel.ty & Classif�Lic. # rch. ngr., ./ L Designer BUILDING: TYPE CONST. OCC. GRP. A.P. Number %'zoo 0O3 Legal Description , ani �? � Project Description 1State EN�114JI Lici LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds ori mproves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of'property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT.. It, after making this Certificate of Exemption you should become subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT J Sq. Ft. 7-iD%A4 No. Size /�z % Stories New PL._ Add ❑ Alter ❑ It It i� 2% No. Dw. Units Demolition ".4, l B ZONE: BY.• _ Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE Estimated Valuation PERMIT AMOUNT Plan Chk. Dep, 3/vp Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. L d Mu Infrastructure 7 ,• T� TOTAL REMARKS P9 I J 10 _21A= AIC 1 A AI 11\CTA P ZONE: BY.• _ Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE Coachella Valley Unified School District 83-733 Avenue 55, 'Thermal, CA 92274-- (760) 398-5909 — Fax (760) 398-1224 Project Name: This Box For District Use Only DEVELOPER FEES PAiD AREA: AMOUNT . LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/MD. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Owner's Name: East of Madison, LLC Project Address: 81-475 Ave. 52, La Quinta, CA Project Description: Guard Houses A & B APN: 767-200-003 Tract #: Date: March 2, 2006 Phone No. (760) 391-5072 Lot #'s: Type of Development: Residential Commercial XX Industrial Total Square Feet of Building Area: 693 sq. Ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: 03/02/06 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT'HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. 693 sq. ft. Amount per Sq.Ft. $ 0.42 Amount Collected $ 291.06 Building Permit Application Completed: Yes/No By: Carey M: Carlson, Asst. Supt., Business Services Certificate issued by: Leticia C. Torres, Facilities Clerk Section 66020 of the Government Code asserted by'Assembly Bill 3081, effective January 1, 1997, requires that this Ict provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. 4tV:::%m�doc:�ldcvfcisic:iriitic:Iii+i+t'umyllianc fonntablisl'Ia USFi.dt':: 1/16/03 T ° Building & Safety Department, c 9ti5 78495•Calle Tampico . of PO Box 92247-1504 La Quinta, CA 92253 (760) 777-7012 voice — (760). 777-7011 fax • c CERTIFICATION 'OF BUILDING AREA STREET ADDRESS OF JOB: 81-475 Avenue 52, Madison Club,. APN: 767-200-003 DESCRIPTION OF WORK: GuardHouses A & B • ' SQUARE FOOTAGE: A= 207 SF, B= 486 SF CONDITIONED AREAS OWNER'S NAME: East Of Madison, LLC. CITY OF LA QUINTA. P.O. Box 1482 BUILDING & SAFETY DEPT. La Quinta, CA 92247 .,APPROVED ` r DATE ?i Y Coachella Valley Unified School District _. 83-733 Avenue 55 P O'Box 847 Thermal, CA' 9227.4 (760) 398 5909 SCHOOL FACILITY FEES COLLECTION HOURS: 8.00 A. M. - 4.00 P.M. Monday - Friday PLEASE NOTE: FEES MUST BE PAID IN CHECK OR CASHIERS CHECK. NO CASH. For questions regarding this letter, please call.-. Ed Randall, Counter Technician. (760) `777-701'2 • r F, LA . o 0 a P.O..Box 1504 LA QUINTA, CALIFORNIA 92247-1504 BUILDING & SAFETY DEPARTMENT C� OFTS. 78-495 CALLE TAMPICO (760) 777-7012 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 April 14, 2006 Ms. Cynthia Zamorez East of Madison, LLC PO.Box 1482 La Quinta, CA 92247-1482 RE: Plan Review Extension Request ._52120 Meriwether Way Dear Ms. Zamorez: I have reviewed your e-mail dated'4/13/16, requesting a time extension for the Plan Review of the Madison Club guard house. proposed to be built at the above address under Application #05-3827. Plan review status: Original application date: 8/30/05 180=day expiration- date: 2/27/06 180 -day extension .date: 8/28/06 Under the provisions of California Building Code Section 1.07.4, your request is hereby granted. Because the Building Code specifies that "no application shall be extended more than once," please be advised that unless a building :permit for this project is issued. on or before Monday, August 28, 2006, your application will expire automatically. Yours truly,. Greg Butler -- Building & Safety Manager Greg.Butler From: Cindy Zamorez.[czamorez@madisonclubca.com] , Sent: Thursday, April .13, 2006 5:28 PM To:. Greg Butler Subject: Caretaker's Residence (81475 Avenue 52; now: 52120 Meriwether Way and 52125 Meriwether Way) Greg: . We are in the final stages of getting the permit for the Caretaker's Residence. The last piece�is getting Green Sheet approval from Public Works .which I hope.should be late next week or by April 28u' (worst case scenario). My glitch, however, is that we applied for the permit on September 28, 2005. and in talking to Burt.this afternoon, it's my understanding that we only have 180 days (or until March 27, 2006) to get our permit issued before the application expires. Since we are very.close to pulling the permit (again only awaiting Green Sheet approval plus we also need the Building/Safety plan check fee), I respectfully request an extension until April 28th to get the permit. We are'anxious to commence -construction so hopefully we won't need that long of an extension, but I don't know Public Works' timeframe. Please advise: Thank you in advance for your consideration of this matter. . Cynthia Zamorez The Hideaway/Madison Club 4/14/2006 i 15. THESE PLANS ARE VAUD FOR A PERIOD NOT TO EXCEED EIGHTEEN (18) MONTHS f ROM UA It _UI- - AWKWAL. THE IMPROVEMENT SPONSOR SHALL BEAR ALL COSTS ASSOCIATED WITH UPDATING THE PLANS, INCLUDING, BUT NOT LIMITED TO DESIGN AND IMPROVEMENT COSTS, TO -AFFECT COMPLIANCE WITH ANY NEW CITY STANDARDS, ORDINANCES, OR LAWS AND REGULATIONS, ENACTED, OR ADOPTED BY THE, CITY OR OTHER JURISDICTIONS WITH AUTHORITY SUBSEQUENT TO PLAN APPROVAL DATE. 16. CONTRACTOR SHALL REMOVE AND ,REPLACE EXISTING SIDEWALK AS NEEDED ED AT LOCATIONS WHERE IT IS CRACKED, UNEVEN AT JOINTS, OR OTHERWISE DAMAGED, PURSUANT TO STREETS & HIGHWAYS CODE SECTION 5610. THIS REQUIREMENT APPLIESTO ALL SIDEWALK LOCATED IN PUBLIC RIGHT OF WAY ADJACENT TO PROPERTY BEING DEVELOPED. OVER -EXCAVATION REQUIREMENTS: OVER -EXCAVATION IS .3' BELOW EXISTING GRADE OR 3' BELOW BOTTOM OF FOOTING WHICHEVER IS GREATER. PLEASE REFER TO SOILS REPORT FOR, FINAL OVER -EXCAVATION, REQUIREMENTS. NOTE: THE OVER -EXCAVATION LIMITS SHOWN ON THESE'PLANS ARE APPROXIMATE ONLY. THE FINAL OVER -EXCAVATION LIMITS AND REQUIREMENTS SHALL BE DICTATED PRIOR TO. COMMENCING ROUGH GRADING OPERATIONS. OWNER&AND DIVIDER EARTHWORK QUANTITIES NAME: EAST OF MADISON; LLC RAW EXCAVATION: 234 C.Y. RAW FILL: 117, C.Y. ADDRESS: 81-100 AVENUE 53 NET: 117 CY. CUT LA QUINTA, CA. 92253 TEL NO. 760-391-5072 SHEET INDEX SHEET NO. DESCRIPTION 1 TITLE SHEET 2 PRECISE GRADING PLAN 3 HORIZONTAL CONTROL PLAN CITY OF LA QUINTA IRECISE GRADING MADISON CLUB t -%l lAr3MUf'%l-l0I7 A 9 D APPROVAL f(11.1 RIVERSIDE*MYNNTY FIRE DEPARTMENT. B DALE EVENSON, FSS. DATE7'7vv_09 —CASE# aAfirAvLj 044 THE FIRE DEPT. APPROVAL FOR PLANS IS VALID FOR ONE YE:kR -SUBJECT I -O COMPLIANCE WITH APPLICABLE CODES THE SOILS ENGINEER HAS. REVIEWED THE PLANS AND FINDS THEM T0. BE IN CONFORMANCE .'WITH THE SOILS. REPORT. REPORT # 544-4810 - DATE: 2/2/06. SOILS ENGINEER DATE DRAWING NAME: -PG-CARETAKER,BLDG-08-01.], PROJECT No. 0001.MDC FEPPPP711 T E C H'N I CAL. S P E C I F I C ATI O N S General door specifications • Top rail height - 5-3/16" — 5-5/8" • Bottom rail height - 8=15%16" • Stile widths - 5-5/16" — 5-3/4" • Stile and rail dimensions include profile, sticking and stop. • Stile and rail material solid, laminated, or engineered with lumber core and heavy veneer — mill option • Muntins - 1-3/8" — 2" • Doors have 1/2"x 4-1/4" hardwood spiral dowels: 2 in top and lock rail, 1 in intermediate rail and 4 in bottom rail. • All panels and mulls float to allow for expansion and contraction. • All panels are solid wood. • One-, two-, and three -panel doors over 1'6" wide have edge -glued panels. • Glazing is always with, tempered or safety glass. • All glass meets ANSI safety specifications. • 3/8" bronze spacer in insulated glass units. • Flat arch — radius is equal to door width, i.e., 36" door = 36" radius • True arches join perpendicular to the stile. • True -arch -top rails are typically 2 pieces. • True arch — radius equals half of door width. • Top half of Dutch door always closes to 1/2 lap of bottom door. • Dutch door shelf is 5-1/2" unless specified otherwise when ordered. • Bottom Dutch door height is always 42" to allow for handset at 36". • 3'x 8'x 1-3/4" 20 -minute label fire door available in Exterior Rocky Mountain and Classic sticking details. • Plank count is based on door width, as follows: 2'4" to 2'6" = 4 planks 2'8" to 3' = 5 planks 3'6" = 6 planks 4' = 8 planks • Lumber is kiln -dried to a moisture content between 7%-9%. Panel thickness Classic 1-3/8" 3/4" Arts & Crafts 5/8" 5/8" Mission 1-3/8" 3/4" Rocky Mountain Jr. 1-3/8" 3/4" Rocky Mountain Sr. 1-3/4" 1-3/8" Sonoran Flush 1-3/8" — French 1-3/8" — Spanish 1-3/8" — Crafted 1-3/8" — Fina 1-3/8" All plank panels 1-1/4" 3/4" Exterior door specifications • Standard door thickness — 1-3/4", optional 2-1/4" • Panel thickness varies based on sticking detail Classic, Arts & Crafts, Mission, Rocky Mountain Jr., Rocky Mountain Sr., Sonoran Flush, French, Spanish, Fina, Crafted. (See chart above) .Interior door specifications • On regular latilla doors, light and air will pass through. • For louver doors, louvers are approximately 3" wide and extend beyond the plane of the door. • Standard door thickness — 1-3/8", optional 1-3/4" • Panel thickness varies based on sticking detail Classic, Arts & Crafts, Mission, Rocky Mountain Jr., Rocky Mountain Sr., Sonoran Flush, French, Spanish, Fina, Crafted Window structural performance data See your dealer or call Architectural Traditions for specific window structural performance data. Window thermal performance data Architectural Tradition's Incense Cedar casement windows meet and exceed the requirements of the NFRC (National Fenestration Rating Council) and NWWDA (National Wood Window and Door. Manufacturers Association). Values based on results from Architectural Testing - residential clr/clr clear/clear 1 lite 1/8" clr + 3/8" spacer + 1/8" clr '0.45 ' 0.42 0.43 clr/clr 3/16" clr + 1/4" spacer + 3/16" clr 0.47 0.42 0.43 clr/clr clear/clear TDL 1/8" clr + 3/8" spacer + 1/8" clr 0.47 0.35 0.34 �z clr/clr 3/16" clr + 1/4" spacer + 3/16" clr 0.49 0.35 0.34; clr/Low E PPG Sungate 500/Low E/clr 1 lite 1/8" clr Low E + 3/8" spacer + 1/8" clr 0.39 0.37 0.40 dr/Low E PPG Sungate 500 Low E/clr 1 lite 3/16" clr Low E + 1/4" spacer + 3/16" clr 0.42 0.37 0.40 clr/Low E PPG Sungate 500 Low E/clr TDL 1/8" clr Low E + 3/8" spacer + 1/8" clr 0.42 0.31 0.32 clr/Low E PPG Sungate 500 Low E/clr TDL 3/16" clr Low E + 1/4" spacer + 3/16" clr 0.45 0.31 0.32 clr/Low E Solar Ban 60 Low E/clr 1 lite 1/8" sbclr Low E + 3/8" spacer + 1/8" clr 0.36 0.23 0.37 x clr/Low E Solar Ban 60 Low E/clr TDL 1/8" sbclr Low E + 3/8" spacer + 1/8" clr 0.40 0.20 0.30 'Residential U -Value 'Residential Solar Heat Gain Coefficient 'Residential Visual Transmittance 41 ��f� 7i/%�� It7 (� _ � % `�! / �� ,, `� Jam/ 1 • . /y ��,/ s6d Architectural Traditions reserves the right to discontinue or change any product, design, function, specification, finish, or price without prior notification. 0 + L.: CA t ;A� C1J cid` T"­>e47� r np570 0 a c t radwi ndows V1\ Prehung options - _ Hardware Flooring �(�Q�Sv� 6i V6jr-S Cabinets Windows. Specifications window Types I window Options I window specifications Window Stickings & Details window species &Finish colors I Window'. - Textures I Glass options I window Case and Trim window structural performance data, See your dealer or call Architectural Traditions for specific window structural.performance data. window thermal performance data windows meet Architectural Tradition's Incense Cedar casement and exceed the requirements of the NFRC (National Fenestration Rating Council) and NWWDA (National wood window and Door Manufacturers Association) '-Values based on results from Architectural Testing'- residential TintcomponentsDescriptionU-ValuelSHGC2VT3 clr/clrclear/clear 1 litel/8'-' Or + 3/8" "spacer + 1/8" c1r0.450.420.43 clr/clr 3/16" Or + 1/4" spacer + 3/16" c1r0.470.420.43 clr/clrclear/clear TDL1/8" clr + 3/8 spacer'+ 1/8"- - c1r0.470.350.34 c1r0.490.350.34 clr/clr 3/16" Or + 1/4" spacer + 3/16" Or Low E clr/Low EPPG Sungate 500/ lr 1 litel/8" 1 clr0.390.37 Or Low E clr/Low EPPG Sunga Low c r 1 1 te3/16" + 1/4" spacer + 16";c1r0. 0:.370.40 Page 2 ROW J00A41TE Lc borestories, Inc.WS INSTANT-FLOWO SR TANKLESS ELECTRIC WATER,, SUBMITTAL SHEET:., Date:'I -.� �• :: Job Name/Customer:�� Uhl Phone:' Location: Contractor: Phone: S ❑, Lavatories 5, `< . r b 4bvQ/ptta o Kitchen / Bar Sinks' t17, ❑ Service Sinks �'�' y ; r x 7 s` .. IlAWSS 14M, •r f �.. s ❑ Scrub Sinks 0. 17 - The point -of -use water heater shall.be a Chronomite Laboratories Instant-Flow"m SR.Tankless Electric Water Heater, Model No. _� with. _ Vac. and Amperage with Celcon waterways and nichrome (Model No.) (Voltage) (Amperage) 4 , a heating coils, or an approved equal. Hot Water Storage vessels are expressly prohibited; Low Flow Rate model with Omni® faucet flow control Standard Flow Rate model with Omni® faucet flow control' _ <,I.OWOW3INDAitD'L��A1RTEMO00E1 SELECT ONE FROM EACH BELOW r .A Low Flow Rate. (0.5 GPM) s v Flow Rate (1.0 GPM) .f 1 Model Tei � - • , 6240 °' 208. -',.'30 Model Watts ' Volts Breaker SR -15L 24°. 1800 110-120,,. 15 SR45L 57° `. 4150 277' - 15 r• 277 � wn SR -20L 3 2400 _ 110-120 a.... -. , 20 SR -2011 ° 4160 208: '20 SR -20L x 5 0 4800 220-240 ' 20 • � . 2120-240, 40 SR -20L 5540 277 y20 SR -30L 49 3600 110-120 ` 30 1 Model Watts Volts Breaker +SR -30 "' ,<42°F 6240 °' 208. -',.'30 .. SR730a 49F 7200 M 220-240'" . .30 .8320 SR -30 r• 277 30`, wn SR -40. 57°F 8320 208 40 SR -40 9600 2120-240, 40 INSTANT -FLOW®- CHRONOMITE LABORATORIES, INC ,. �o.• ' s , , .F :rr 1420 W. 240th Street, Harbor City- CA'90710 U.S.A. z Customer Service Toll -Free: (800) 447-49662 p . (310) 534-2300 Fax: (310) 530-138: �. www.chranomite.cum a page I c.�� s, LcibOrestori4es, Inc. INSTANT-FLOW® SR - TANKLESS ELECTRIC WATER HEATERS" ' 1�OLTGED%�IIIIPE�E SEIEtCT1N OBD 1. SEit{E LOW FLOW STANDARD FLOW Model Series SR-15L; Model Series SR-30 120 VAC/ 15 Amps r 208 VAC/ 30 Amps ' 277 VAC/ 15.Amps r _ 240 VAC/ 30 Amps .277 VAC/ 30 Amps a ' Model Series SR-20L i. rik a• 7 Model Series SR-40 �' y 208 VAC/ 20 Amps '` -' =20& VAC/ 40 Amps ` 240 VAC/ 20 Amps r 240 VAC/ 40 Amps r 277 VAC/ 20 Amps For wire size, please refer to: ' Model Series SR-30L Table 310.16 National Electric Code 120 VAC/ 30 Amps F ��{ wry'a R hx�%�x{�,,E ' : `", AlR1ftL INION „, .. { . • 2 Standard Flow Rate Models in Parallel - r 2.0 3.0 GPM Flow Rate (discharge side). 0 Two Model SR-30/277 (plumbed-in-parallel) ❑ s Two SR-40/240 (plumbed-in-parallel) trj 57°F Temp. Increase at 2.0 GPM Flow Rate : •x.66°F.Temp. Increase at 2.0 GPM FlowRate g _ ❑ Two Model SR-40/208 (plumbed-in-parallel) 57'F Temp. Increase at 2.0 GPM Flow Rate Note: When heaters are plumbed-in-parallel, separate electrical service must be installed for each individual heater. �iAISCELt.A`NO.US� 2n, i..15._;'t. ^.�+e.,�.,«._�..:.,. o.,w.i,,w,�...,�, ra, .•m, .�. n�.�i."=�2-�w�,.n��e TYPICAL INSTANT-FLOW® HEATER WIRING DIAGRAM - Dimensions: 61/4'X 95/- x 23/4•. - Weight: 5 Lbs. �.. �„ - Materials: Rugged cast- aluminum alloy housing and Celcon +° Nenaar Noeut waterways with nichrome parts ,„ (unless stainless steel housing) M;uAmmon - Maximum �,• Operating Temp: 1401F y �' iLtHl'GJI€ti�liLk7 Minimum Operating Pressure: '25 psi Maximum Operating mom. Pressure: 150 psi t . - Listings : UL, IAMPO, HUD? - Warranty: (1) one year',,' r MODEL NUMBER SELECTION' - Example: SR-301_120 VAC 30 Amos ' Model No. ,- 'Voltage , Amperage For Optional Stainless Housing add "SS" Example: `,SR-30LSS' 120 VAC 30 Amps - ` INSTANT-FLOW ®- CHRONOMITE LABORATORIES, INC. ' 1420 W. 240th Street, Harbor City • CA 90710. U.S.A. ; t • a Customer Service Toll -Free: (800) 447-4962 (310) 534-2300 Fax: (310) 530-1381 x 5 Form SS-50 www.chronomite.coti,w A Division of Acorn Engineenng page2 - • ��H/20N0/1/l . ; i. - . l TE " - '. � t - � ��. r - LOW FLOW - 0.5 GPM MODEL NUMBER CHANGE . S -SERIES SR -SERIES_ f A . de ' -tt'ag `'tloi '� esker 'I�O � oriel = atxOge ' �ti x S 23L 2300 120 20 ` 320F SR -20L - ' 2400 120 20 330F ' ` `REMAINS S -23L 2300 .2018. 15 32°F 4.1 , S -23L/208 S -23L ' 2300 220-240 15 k f� ' `32°F ; REMAINS S -23I:/220-240 i '` . r F', • _ } S -30L •.3000 110/120 - r30 SR -30L 3600 t' 120 30 49°F .S -30L 3 000 208 ° 4 20 ' ` 1. F. 40° SR 20L ,4160 " 208 _ 20 ,57°F 3-30L 3000', 220-240 y 15 '�40°F s.' } i'�$�'{-.REMAINS.S-30L/220-240`F- ' 31' f 3 -S-30L y, 3000 ' 277° - 15_$,,r !40°F S46IL 4600 "208 r 30 S,46IL '":' 4600. 220/240 r 30 ` '_ 63°F; "' SR -20L' 4800. 240 20 `65°F= r �S-461L, 4600 277 20 63°F SR -20L 5540, 277 `r20 750 F � � „� Laboratories, Inc.{* r N' '.� w FJ4 •' ',� * �'�eoa i-,"'IN�Chronomlte esg�Met' ,91420 West 240`d Street flnst /Spece _ "NO rng/ ,8 'Harbor City„ CA 90710 Tel 800-447=4962 Fax 310-530-1381 r, • a t :. i r Small Electric Instantaneous Water Heaters Certified to the California Energy Commission as of 10/13/2005 Page 1 of 10 � m E m E c CD . o 3 v E Z ~ C E =ti > > Z 13 2 LM 12 0 2 w A 0 Smith Water Products A 0 Smith Water Products CM -12** No Match FALSE 4 57.3 12 0.98 A 0 Smith Water Products A 0 Smith Water Products CMD -12 No Match FALSE 16 55 12 1 A 0 Smith Water Products Lectros eed CM -12 No Match FALSE 15 58 12 1 A 0 Smith Water Products Lectros eed CMD -12 No Match FALSE 15 58 12 1 A 0 Smith Water Products National CM -12** No Match FALSE 14 57.3 12 10.98 A 0 Smith Water Products National CMD -12 No Match FALSE 16 55 12 1 Chronomite Labs Chronomite Labs MF -200-3C 30 PHASE No Match FALSE 10.2 1 23 9.2 0.98 Chronomite Labs lChronomite Labs MF -200C 220-240VAC No Match FALSE 10.2 40 9.2 0.98 Chronomite Labs Instant -Flow S -23A 110-120VAC No Match FALSE 10.1 10.9 2.3 0.98 Chronomite Labs Instant -Flow S -23B 208VAC No Match FALSE 0.1 10.9 2.3 0.98 Chronomite Labs Instant -Flow S -23C 220-240VAC No Match FALSE 0.1 10.9 2.3 0.98 Chronomite Labs Instant -Flow S -30A 110-120VAC No Match FALSE 0.1 14 3 0.98 Chronomite Labs Instant -Flow S -30B 208VAC No Match FALSE 0.1 14 3 0.98 Chronomite Labs Instant -Flow S -30C 220-240VAC No Match FALSE 0.1. 14 3 0.98 Chronomite Labs Instant -Flow S46B 208VAC No Match FALSE 0.1 21.2 14.6 0.98 Chronomite Labs Instant -Flow S46C 220-240VAC No Match FALSE 0.1 21.2 4.6 0.98 Chronomite Labs Instant -Flow S -60B 208VAC No Match FALSE 10.1 27.5 6 0.98 Chronomite Labs Instant -Flow S -60C 220-240VAC No Match FALSE 10.1 27.5 6 0.98 Chronomite Labs Instant -Flow S-706 208VAC No Match FALSE 0.1 32 7 0.98 Chronomite Labs Instant -Flow S -70C 220-240VAC No Match FALSE 0.1 32 7 0.98 Chronomite Labs Instant -Flow S -80B 208VAC No Match FALSE 0.1 36.5 18 0.98 Chronomite Labs Instant -Flow S -80C 220-240VAC No Match FALSE 0.1 1 36.5 18 0.98 Chronomite Labs Instant -Flow S -90C 220-240VAC No Match FALSE 0.1 1 41.1 19 0.98 Controlled Energy Corp. PowerstreamPro RP12PT Ozone -Depleting ITRUE 0.1 10.1 65.2 12 0.98 Controlled Energy Corp. PowerstreamPro RP1P Ozone -Depleting ITRUE 0.1 10.1 49.8 9.5 0.97 Controlled Energy Corp. I PowerstreamPro RP2P Ozone -Depleting ITRUE 0.1 0.1 3.EF 6 0.98 Controlled Energy Corp. PowerstreamPro jRP3P Ozone -De letin ITRUE 0.1 10.1 117.8 3.4 0.98 Page 1 of 10 O INSTALLATION AND MAINTENANCE ®17 - INSTRUCTIONS 21000 TEMP/GUARD CHIMNEY SIZES 6"-7"-8"-10"-12"-14" 17000TEMP/GUARD CHIMNEY SIZES 16" - 18" TEMP/ GUARD® U� This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Listing No. MH 8251 Tested to 103 HT A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIAL." MINIMUM CLEARANCE FOR 6" - 8" TEMP/GUARD IS ONE AND A HALF (1-1/2) INCHES. MINIMUM CLEARANCE FOR 10" - 18" TEMP/GUARD IS TWO (2) INCHES. IT IS OF UTMOST IMPORTANCE THAT THIS CHIMNEY IS INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS. 'Combustible material is defined as material made of, or surfaced with, wood, compressed paper, plant fibers, plastic, or other material that will ignite and bum, whether flame proofed or not, or whether plastered or unplastered. The Metal -Fab Temp/Guard Chimney is intended for use on any residential and building heating appliance buming gas, liquid or solid fuels such as fireplace stoves, fumaoss, ranges, room heaters, or as defined in columns I and II, Table 2-2.1, NFPA 211. Contact Local Building or Fire Officials about restrictions and Installation Inspection in your area. WARNING: Metal -Fab Temp/Guard Chimney Is not designed for use on products that operate.at continuous temperatures In excess of 1,0000F. OPERATIONAL PRECAUTIONS • Maintain 1-1/2" minimum clearance to combustibles for 6"-8" diameters and 2" clearance to combustibles for 10'-18" diameters. Use only U.L. Listed products and _INSTALL ONLY IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. • Formation of Creosote and Soot and the need for removal. When wood is bumed slowly, it produces tar and other organic vapors, which combine with expelled moisture to create creosote. The creosote vapors condense in the relatively cool chimney flue of the slow buming fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire. The chimney should be inspected at least once every two (2) months during the heating season to determine if a creosote or soot buildup has occurred. If creosote or soot has accumulated, it should be removed to reduce the risk of chimney fire. • Do not use fireplace for food grill. Grease from foods can collect in chimney causing fireplace to become a potential fire hazard. • On airtight stoves, open dampers and let equipment bum hot for 15 to 20 minutes. This should be done every time fuel is added. This lessens the chance of creosote buildup. • Some chemical chimney cleaners can be harmful to the chimney. These cause accelerated oxidation or corrosion. If chemical cleaners are used, they must be non -corrosive in nature. If brush is used, it must be of proper size with plastic bristles. PAINT TOUCH-UP • The flat -black paint used on painted parts may be touched up, as required, with Stove Bright® Product No. 1990. MASONARY FIREPLACE CHIMNEY, AND CHIMNEY EXTENSION An anchor plate (TGAP) Is used to attach Metal -Fab 2100'F or 1700°F Chimney to a masonryfireplace or chimney. Maximum support height of 60 ft (45 ft for 14",16" and 18"). 1. Where the transition is to be made, apply a bed of mortar approximately 3/4 inches deep and approximately one (1) inch larger than the anchor plate. (See TG Chimney Catalog for anchor plate dimensions). 2. Insert four (4) 1/4-20 x 2" anchor bolts, head down into the mortar bed. J -style anchor bolts are preferred. An alternate method would be to allow the mortar bed to cure. Then, drill four (4) holes, matching the holes in the anchor plate and insert four (4) each 1/4-20 metal anchors. The anchor plate would then be attached by four (4) each 1/4-20 bolts. 3. Before the mortar sets, place the anchor plate over the bolts and press down into the mortar. Loosely secure using a washer and nut on each bolt. FIG. 14 4. Use a level to check the installation, assuring that the TG chimney connection (TGAP) is level. 5. When the mortar has set up, tightenthe nuts onto the bolts. Proceed to stack Metal -Fab chimney pipe (TG) on the anchor plate. 6. When installing the 14TG, 16TG and 18TG chimney system, use the flange bands for each flue connection and the closure bands around the casing connections. Prior to installing the closure band, wrap the flue with the ceramic insulation provided with each section.. NOTE: No insulation is required when attaching the chimney cap. 7. To attach the 14TGC, 16TGC and 18TGC cap to the chimney, set the flue flange of the cap on the flue flange of the last piece of pipe. Rotate the V -band around the flanges and tighten. Wrap the closure ring around the flue of the cap and tighten. This closure ring protects the area between the flue and the casing and keeps moisture out of this area. 8. See "Flashing Instructions" and'Termination" sections. NOTE: Existing masonry flues may be extended with TG pipe by using an anchor plate, following steps 1 through 7 above, provided that 0.375 DIA. - MIN. HOLE a) The existing masonry chimney is structurally sound, (4) PLCS. and; b) The flue extension is properly sized so that the FIG. 15b 14TG, 15TG, AND 18TG ANCHOR PLATE appliance attached to the flue drafts properly. NOTE: The TG flue size for a height less than 15 feet should be at least 1/8 the area of the fireplace opening. The TG flue size for a height over 15 feet should be at least 1 /10 the area of the , z , fireplace opening. (For sizing of TG flue, See Metal -Fab literature L1372.) EXAMPLE:.A fireplace opening of 22" x 34" has an area of (748 inz) with a chimney height less than 15 feet, the effective area is 1/8 x (748 int) = 93.5 W. Closest flue diameter size = 10". With a chimney height over 15 Feet, the effective area is 1/10 x (748 in2)=74.8 W. closest flue diameter size = 10". FIG. 16 NCHOR IBEODED MORTAR PLATE GAP) Q,NF MORTAR NOTE ANCHOR PLATE MOUNTED AT MASONRY FIREPLACE FLUE OPENINGAREA WITH, BOLT, NUTS, AND 'WASHERS FIG. 15a 14TG THROUGH 18TG DETAIL cnP CLOSURE RING CLOSURE RING PIPE 14' REF. �+ -16' REF. -+j I 18' REF. I 9' REF. 1TYP� 22' MIN. SO. 24' MIN. SO. 26' MIN. SO. S.S. ANCHOR PLATE MORTAR MASONARY L, PART 3 PRODUCTS a �; 3.1 ALL-FUEL CHIMNEY A. The chimney shall be of the double-wall, factory-built type for use with listed solid fuel, liquid, or gas fired appliances, which produce flue gasses exhausted at temperatures not exceeding 1000°F continuous burn or 2100°F intermittent bum. B. The chimney, in sizes 6"-12", shall be constructed of an outer wall of either .012" thick 430 .stainless steel or .018" thick G-90 galvanized steel. The inner wall construction, for these sizes, shall be of .015" thick 430 stainless steel. The chimney, in 14" size, shall be constructed of an outer wall of .024" aluminized steel. The inner wall construction, for 14" size, shall be of .035" stainless steel. The chimney shall include an integral, annular insulated space of 1 V for sizes 6"-12" and 2" for the 14" size. - C. The flue conduit shall be wrapped with ceramic insulating material. D. The chimney shall be tested and. listed for a minimum clearance to combustibles.of 2" . E. All fittings, flashing, storm collar, anchor plate, ceiling support, and cap required to install the chimney shall be included. '. F. Anchor plate construction shall be of .060" Type 304 stainless steel factory attached to a starter section of double-wall factory-built chimney. - G. Chimney shall be Model Temp/Guard as manufactured by Metal-Fab Inc. H. Temp/Guard chimney shall be installed in accordance with the, chimney manufacturer's installation instructions, UL listing and state or local codes. , MM EUTIA W I P.O. Box 113$:• Wichita, KS 67201 Uft w u.SA: (316}.943.2361 - FAX •(3.16) 943.2717 02M MsW-Fab. iK Frm, Nn i 1199 of-o1 wso TEMP/GUARD PITCHED CEILING .STORM COLLAR . FLASHING ADJUSTABLE SUPPORT (Under the flashing) PITCHED CEILING PLATE' PAINTED TRIM SLEEVE' SINGLE WALL ADAPTER TEMP/GUARD HIGH-PITCHED CATHEDRAL CEILING CAP SINGLE OR DOUBLE WALL BLACK PIPE ROOF SUF SINGLE OR C BLACK PIPE TEMP/GUARD MASONRY CHIMNEY EXT......,,. STORM COLLAR CHASE COVER CAP (sitebuin) iASE (sflabuin) T/G PIPE ANCHOR PLATE (Embedded In concrete) MASONRY CHIMNEY (Existing) DRM COLLAR LASHING Note:Twist Lock Pipe (6'-12') overlaps 11b' when joined together. Therefore, assembled length is 1Y2' less than listed length. Temp/Guard® All -Fuel Chimneys Double-wall, factory -built type for use with listed wood, coal, oil or gas-fired appliances. . • Sizes 6', 7', 8% 10', 12' and 14" are listed by Underwriters Laboratories Inc. to UL Standard 103HT (2100° intermittent; 1000° continuous). • Sizes 16' and 18' are listed by Underwriters Laboratories Inc. to UL Standard' 103 (17000 intermittent; 10000 continuous). *The S.S. flue conduit is wrapped with ceramic insulating material. •Temp/Guard is tested and listed for a minimum clearance to combustibles of 2". • Application Reminder: For oil or coal burning appliances, use only pipe with S.S. casing and S.S. or Aluminum accessory components outside the envelope of the building. • Appliance Caution: Temp/Guard is intended for use in residential and building heating appliances that operate at continuous temperatures below 10000. CHIMNEY PIPE — 6" -12" TGS (Stainless casing) and TGG (Galvanized casing) C 0 B SIZE' 6 7 (1) 14 listed to 2100 intermittent; ,':SIZE..,; 14' ;' 16 ;'78':: 1000* continuous 6 7 8 10 12 I 9 10 11 13 15 flange to flange (diagram 1); retained by securing a flange 6, 12, 18, 24, 36, and 48" inch lengths band over the mating flanges (diagram 2); wrapped at the •48' lengths of 10' and 12' not available The outer casing of stainless or galvanized provides strength, durability, and corrosion resistance. Twist lock enables fast, easy installation, without tools. Always use TGS for exterior pipe in oil applications. CHIMNEY PIPE —14" -1lr TG (Aluminized outer casing) FLANGE BAND Notes: CLOSURE BAND (1) 14 listed to 2100 intermittent; ,':SIZE..,; 14' ;' 16 ;'78':: 1000* continuous A +1 14 16 18 (2) 16' & 18listed to 1700` intermittent; 1000° continuous 18 20 22 ";rC°;;-s 9, 18, 30, and 42 inch lengths I For the 14", 16°, and 18' diameters, the flues are installed C flange to flange (diagram 1); retained by securing a flange band over the mating flanges (diagram 2); wrapped at the joints with insulation (diagram 3); and covered by a closure band (diagram 4). Diagrams: 1� 2rC 3<7�:h• '4A� CLOSURE BAND DELUXE CEILING SUPPORT - TGDLXS � The deluxe support provides round "barrel" design. f----�-14.44"�--1 The "barrel" hasTemp/Guard pipe adapter built into it: Comes with both round and square trim plates: 5.94" i (square plate shown) WALL SUPPORT/ADAPTER - FIXED - TGWS Stainless casing B ffF.51N`e .�l �•' �qlX� 4tw 4.31" SIZE 6" 7" 8" 10" 12" A 9.0 10.0 11.0 13.0 15.0 B 6.5 7.0 7.58.5 12 9.5 C 17.5 17.5 175 175 17.5 Note: Mounting spacing is 16" O.C. for all sizes.This fixed spacing wall support is designed for use with the insulated tee to provide support for the chimney which has a lateral connection passing through the combustible wall. Support allows access from below to tee cap. The maximum height of chimney which may be supported is 60 ft. WALL SUPPORT/ADAPTER - ADJUSTABLE - TGAWS Stainless casing A C ANCHOR PLATE - 6" -12" TGAP ANCHOR PLATE -14" -18" TGAP A L B SIZE 6" 7" 8" A 9.00 10.00 11.00 B 5.00-11.00 5.50-11.50 750-13.50 C 1750 17.50 17.50 The adjustable support enables adjustments in clearance to combustibles from 2" - 6". SIZE 6" 7" 8" 10" 12" A 6 7 8 10 12 B 12 13 14 16 18 The stainless steel anchor plate provides a positive connection to the smoke chamber on top of the masonry fireplace. 6" - 12" also used with chimney tee on masonry pier. SIZE 14" 16" 18" A 14 16 18 B 22 24 26 C 9 9 9 1 Big WS Inc.. Number of hits: 18 The maximum number of hits returned is 5000. Previous Page Refine Your Search • Home Company Name Category Name Link to File METAL -FAB INC Ceiling Dampers C"&R16484 METAL -FAB INC Chimney and Vent Connectors and Accessories Y. ODCMH25730 METAL -FAB INC Chimneys, 1400 Degree Fahrenheit DD7Z.MH8251 METAL -FAB INC Chimneys, 1400 Degree Fahrenheit Certified for Canada DD777.MH8251 METAL -FAB INC Chimneys, Residential Type and Building Heating Appliance DDXU.MH8251 METAL -FAB INC Chimneys, Residential Type and Building Heating Appliance Certified for Canada DDXU7.NH8251 — METAL -FAB INC Dampers for Fire Barrier and Smoke Applications EMME.R16483 METAL -FAB INC Gas Vents DFFZ.MH7860 METAL -FAB INC Gas Vents Certified for Canada DFFZ7.14H7860 METAL -FAB INC Grease Ducts HNOS.R15388 METAL -FAB INC Grease Ducts for Restaurant Cooking Appliances YYG .MH25506 METAL -FAB INC Grease Ducts for Restaurant Cooking Appliances Certified for Canada YYGQ7.MH255OG METAL -FAB INC Liners DDZR.MH17528 METAL -FAB INC Low-temperature Venting Systems, Type L DFYX MH16402 METAL -FAB INC Special Gas Vents DGSH.MH26687 Page: 1 2 Previous Page Notice of Disclaimer • Questions? Model number information is not published for all product categories. If you require information about a specific model number, please contact customer service for further assistance_ T t/ C-�u'4"S -,6 D Number of hits: 18 The maximum number of hits returned is 5000. Previous Page Refine Your Search Home Company Name Category Name Link to File METAL -FAB INC Special Gas Vents Certified for Canada DGSH7.MH26687 METAL -FAB INC Through -penetrating Products XHLY.R25388 METAL -FAB INC Through -penetrating Products Certified for Canada XHLY7.R15388, . Page: 2 Previous Page Notice of Disclaimer Questions? Mgdd number information Is not published for all product categories. If you require information about a specific model number, please contact Customer Service for further assistance. u` Undters Laboratories Inc. DDCY-MH25730 Chimney and Vent Connectors and Accessories See General Information for Chimney and Vent Connectors and Accessories METAL -FAB INC NM5730 3025 MAY AVE PO BOX 1138 V WICHPTA, KS 67201 USA Model Connector Size In. Min Clearance In. NECK, MLCK-1, MSWF, MSWFA 3, 4, 5, 6 1 MDWF 3, 4, 5 1 For use with category one gas appliances as defined by NFPA 54. 1 in. minimum air space clearance to combustibles. Not for installation m attics, should not pass through walls, floors, ceilings or other combustibles, should not be enclosed. The Model MDWF vent connector is suitable for use in an unenclosed "segment" of a Type "B" gas -vent system in attics and crawl spaces. u Last Updated on 2002-01-02 This page and all contents are Copyright ® 2005 by Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow - Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non -misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright ® 2005 Underwriters Laboratories Inc.®" An independent organization working for a safer world with integrity, pre.lsion and knowledge. U� Underwriters Laboratories Inca DDTZ.MH8251 Chimneys, 1400 Degree Fahrenheit See General Information for Chimncys.140D Degree Fahrenheit METAL -FAB INC MH8251 3025 MAY AVE PO BOX 1138 WICHITA, KS 67201 USA "These chimneys are intended for installation in buildings other than one or two family dwellings and are to be installed unenclosed, at the specified minimum clearance to combustible materials and with clearance at the roof structure as established by the installation of designated factory furnished roof thimbles and supports. These chimneys shall be installed with all required UL Listed parts specified in the Installation and Maintenance Instructions provided with each chimney system. The maximum chimney height shall not exceed the specified height for the support system indicated in the instructions. Model Chimney Size In. Min Clearance LL Max Vertical Height (Ft) PIC 6-16 4 + PIC 18 6 + PIC 20 8 + PIC 22 9 + PIC 24-48 10 ++ IPIC-1 6 1 + IPIC-1 8-16 2 + IPIC-1 18-26 3 + IPIC-1 28-32 4 + IPIC-1 34-40 5 + IPIC-1 42-48 6 + IPIC-2 6-34 1 + IPIC-2 36-48 3 + IPIC-4 6-34 1 + IPIC-4 36-48 3 + +Refer to manufacturer's installation instructions for specific height per support method. Last Updated on 2002-09-05 This page and all contents are Copyright 0 2005 by Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow - Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non -misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright 0 2005 Underwriters Laboratories Inc.®" An Independent organization working for a sater world with integrity, precision. and knowledge. 0 U` Underwriters Laboratories Inc e DDXU.MH8251 Chimneys, Residential Type and Building Heating Appliance See General Information for Chimneys Residential Type and Building Heating Appliance METAL -FAB INC MH8251 3025 MAY AVE PO BOX 1138 WICHITA, KS 67201 USA These chimneys shall be installed with all required Listed parts specified in the Installation and Maintenance Instructions provided with each chimney system. Residential Type Chimneys shall be installed with the specified minimum clearance (air space) to combustible enclosing walls and roof structure and with clearances, at floors, joists and ceilings as established by the installation of designated factory famished supports and firestop spacers. Building Heating Appliance Type Chimneys for buildings other than one or two family dwellings are to be installed unenclosed, at the specified minimum clearance to combustible material. -Chimneys for use with offsets shall incorporate no more than the maximum number of elbows with the related maximum chimney height as specified in the installation instructions. The chimney heights indicated in the following table represent a specific support system that provides for the maximum chimney height. The maximum chimney height shall not exceed the specified height for the support system indicated in the instructions. Residential & Building Heating Appliance Model Chimney Size In. Min Clearance In. Max Vertical Height (Ft) TG+, Type HT 6, 7, 8 1-1/2 ++ TG+, Type HT 10, 12,14 2 ` '++ TG 16 and 18 2 ++ Building Heating Appliance Model Chimney Size In. Min Clearance In. Max Vertical Height (Ft) PIC* 6-16 .4 ++ PIC* 18 5 ++ PIC* 20 6 ++ PIC* .22 7 - n .. T, 8 ++ PIC* 26 9 ++ PIC* 28-48 10 ++ PIC* 20 6 ++ PIC* .22 7 ++ PIC* 24 8 ++ PIC* 26 9 ++ PIC* 28-48 10 ++ IPIC-1 * 6 1 ++ IPIC-1* 8-16 2 ++ IPIC-1 * 18-26 3 ++ IPIC-1 * 28-32 4 +.F IPIC-1* 34-40 5 ++ IPIC-1* 42-48 6 ++ IPIC-2* 6-34 1 ++ EPIC -2* 36-48 3 - ++ IPIC-4* 6-34 1 ++ IPIC-4* 36-48 3 ++ +May be attached to masonry fireplace when Cat. No. TGAP adaptor is used. ++Refer to manufacturer's installation instructions for specific heights per support method. *Denotes suitable for installation in positive pressure applications at a maximum rated internal pressure of 60 in. W.C. Last Updated on 2004-07-23 This page and all contents are Copyright © 2005 by Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured tinder UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow - Up Service. Always look for the Mark on the product UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non -misleading manner, without any manipulation of the data (or drawings). 2. The statement 'Reprinted from the"Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2005 Underwriters Laboratories Inc.®" An Independent organization working for a safer world with Integrity, precision and knowledge. #y TITLE 24 REPORT Title 24 Report for: Madison Club Guardhouse Building B Meriwether Way La Quinta, CA .t Project Designer: Nick Fullerton Architects P.C. 424 South Main Street Kalispell, MT 59901 4067257-4091 Report Prepared By: Dave Celmer, P.E. EquitySpec Consulting Engineers, Inc. 4508 N. Sierra Way Suite 115 San Bernardino, CA 92407 (909) 881-7278 CITY OF LA QUANTA BUILDING & SAFETY DEPT. APPROVED OR CONSTR CTI Job Number:. LB 05019 AT Z fes- Date: 10/13/2005 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC = www.energysoft.com. EnergyPro 4.0 by EnergySoft Job Number: 05019 User Number: 4582 y �� PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 PROJECT NAME This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building Madison Club Guardhouse Building B DOCUMENTATION AUTHOR PROJECT ADDRESS he Principal Meriwether Way La Quinta nsistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this [permitapplication. The proposed building as designed meets the energy efficiency requirements PRINCIPAL DESIGNER - ENVELOPE Nick Fullerton Architects P.C. TELEPHONE L� 1. ' hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person 406-257-4091 DOCUMENTATION AUTHOR EquitySpec Consulting Engineers, Inc. TELEPHONE (909) 881-7278 T DATE 10/13/2005 aunaing; rermR '. Checked'by/Date . 'Enfercemant Anonri i.i�e 8.17.05 486 Sq.Ft. 15 BUILDING TYPE ® NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTEUMOTEL GUEST ROOM PHASE OF CONSTRUCTION [K] NEW CONSTRUCTION ADDITION 0 ALTERATION EXISTING + ADDITION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation Is ac.ctWate and complete. DOCUMENTATION AUTHOR 7SIGN:ATU ATE Dave Celmer, P.E. he Principal Designer hereby certifys that the proposed buildin design represented in this set of construction documents is nsistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this [permitapplication. The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116, rough 118, and 140, 142, 143 or 149 of Title 24, Part 6. ENV. L . MECH. L� 1. ' hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person sj reparation; and that I am licensed in the State of California as a civil engin r mechanical engineer, 1 am a licensed architect. 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures I PA Required F NV -1 PRINCIPAL ENVELOPE DESIGNER - NAME SI TU LIC. NO. DA E Nick Fullerton Architects P.C. C- 5 e94 - LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Lighting Compliance Not In The Scope Of Required Forms Tllis Submittal PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC. NO. DATE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ,- Required Fo s MECH-1 MECH-2, MECH-3 PRINCIPAL MECHANICAL DESIGNER - NAME SIGNA LI NO. E uit S ec ConsultingEngineers Inc. ZZ I�,a MO. 4.0 by EnergySoft User Number: 4582 Job Number: 05019 Pane:3 of 15 f, F 411s r Vit, r • PERFORMANCE CERTIFICATE OF COMPLIANCE Part2 of 3 , 4 'PERF PROJECT NAME DATE .: : Madison Club Guardhouse Build ing.B ' : " .a 10/13/2005 ,ANNUAL TDV ENERGY USE SUMMARY _ kBtu/s ft, r _. • ,' , ENERGY COMPONENT Standard Design Proposed , )Compliance, Design . '. f."„ Margin,'! " ° steoaam :ff M eio°o:ed 'Space Heating 5.41 a ,s 1.57 3.84 Space Cooling 20872: ° 17513' 'Rr.' 33:59 Indoor Fans 124.81 s ,'''" ,,;114.82 „ 10.00. - +R m Heat Rejection • ` 0.00 � _ Pumps &'Misc 1X..' 0.00 " 0.00 �: Domestic Hot Water 19.23 �'�18.25`�°'"' y •, 0.98 � ' __ ., • . _. Lighting 79.61 r;w, 79.61 a : "o.00 Receptacle s1.5a 915a 0.00 Process 0.00 ~ ,o 00 ` : 0.00 TOTALS:, 529.33 F" 480.92 ^� • 748:41 .Percent better'than Standard: 9.1% •'( ,19.1% -excluding process) BUILDING. COMPLIES - GENERAL INFORMATION Building Orientation Number'of Stories`; Number of Systems Numberof Zones West 270d'" h_ 1 f� Conditioned Floor-Are_a '; °48s sgft Unconditioned -Floor Area!;- 0 sgft Conditioned Footprint Area 0 sgft Al Fuel Type _, " Y" . - !Natural Gas r • ' fir z Orientation "Gross Area `Glazing Area -Glazing Ratio ' ' • Front Elevation,,st r (We 308 sgft $ sq' 2.6% w d r r Left.Elevation s M "(North) s ` 168 sgft 3 :, 78 sgft' ."._46.1'/0 ` Rear Elevation L n ` :, East 308 sgft , R.. 36 sgft. 11.8% l Right Elevation , " n _ " (South) , 168 sgft. 12 sgft: 7:4% e, Total °. a-' 952 sgft. r, 134 W. 14:1% ..:Roof • � -j48s (sgft } s ' ' gft:', Standard # Proposed`` +` k� Lighting Power Density,`1:20o W/sgfi. 1.200 W/s Prescriptive Env. Heat Loss .17119tu/h a, 128 Btu/h'-r, .. - sur• t f -F 4 , t_� w - "Prescriptive Env. Qs Heat Gain is;451 Btu/h-E, 13;580 Btu/h-F . ,s y - .;. Remarks: r 4 fi A y5Y3• w i w .i f# + a Y .. r e j.; ] � ' a � � ar,e, ��'( Q•�', "R.eC :f=;. a 4' _ !'• Run:Initiation Time: 10/13/05 13:10:55 Run Code: 1129234255 EnergyPro 4.0 by EnergySoft . User Number: 4582 Jo3b,Number: .05019 Page:4.of 15 iz - a PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 PROJECT NAME DATE Madison Club Guardhouse Building B 10/13/2005 ZONE INFORMATION Floor Inst. Ctrl ' Allowed LPD Proc Area LPDCreditsg Loads X Area> Tailored System Name Zone Name Occupancy Type (sqft.) (W/sf)1 .(1Nlsf)?_ t Is 3 /s4. FC/HP-B BIdg.6 Office 486 *1.200:e ..�`��, <�,� � ,; >, :.:,��,• f. ?^ i %. a u� 31 (X � Notes: 1. See LTG -2-C 2. See LTG -4-C 3. See LTG -5-C 4. See LTG -6-C Items above regwre'speci*al documentation, ; (items marked with asterisk, see LTG -2 -C by others) (by others) EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST • ••" •�--•-•••-•--•••-----V--7 -� Wusu FOr OFWUNOI atLWII VII LU LI IV nems spec mea in [nes cnecKust. i nese items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Not Valid for permit applications submitted on or after 01/23/06 because Energy Budget is based on SEER 10. C.UWF&UNION Ieu.ures nsLea In ims perrormance approacn appimation nave specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. or EnergyPro 4.0 by EnergySoft User Number: 4582 Job Number 05019 Page:5 of 15 CERTIFICATE OF COMPLIANCE ENV -1-C PROJECT NAME DATE Madison Club Guardhouse Building B 10/13/2005 OPAQUE SURFACES # Surface Type Area U -Fac. Insulation Cay. Cont. Act. Azm. Tilt Cond' Status Joint Appendix IV Reference Location / Comments 1 2 3 4 5 Wall Wall Wall Wall Roof 90 272 300 1561 486 0.069 0.069 0.069 0.069 0.025 R-21 R-21 -21 R-21 R-38 R-0.0 R-0.0 R-0.0 R-0.0 0 90 270 180 0 90 90 90 90 0 New New New New New 09-A6 09-A6 09-A6 09-A6 01-A18 Bldg B Bldg B Bldg B Bldg B Bldg B /1\ 11-(eMne T,.nn• 11 a_n n • M c e o /Lill C.. FENESTRATION^ SURFACES More than or equal to 10,000 sq.ft, of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default U -factors from Standards Table 116-A and B. Certificate shall be filed in the contractor's ro'1ect office durin n # 1 2 3 I T e Window Window Window Left (North) Rear East Front West Area U -Fac' SHGC2 78 0.390 NFRC 0.37 NFRC 36 0.390 NFRC 0.37 INFRC 8 1.280 116 -Al 0.67 116-B g co Act. Am. 0 90 270 s ruc on an In the building manager's office after construction Cond. Location/ Stat. Glazing _Type Comments New Arch.Traditions Clad 2 -pane low -e Bldg B New Arch. Traditions Clad 2 -pane low -e Bldg B New Single Metal Tinted Bldg B 4 Window Right South 12 0.390 NFRC 0.37 NFRC 180 New Arch.Traditions Clad 2 -pane low -e Bldg B /1\ 11-(eMne T,.nn• 11 a_n n —umeuii Table from me ACM manual Appendix, NFRC Labeled value. W SHGC Type: 116-8 Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type HGC Hgt. Wd. Len. H t. LExt.RExt. Dist. Len. Hgt. Dist. Len. H t. 1 None 0.76 2 None 0.76 3 None 0.76 4 None 0.76 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES ❑The proposed building contains an enclosed space with Floor area greater than 25,000 sq.ft, a telling height greater than 15 feet and a LPD for general lighting of at least 0.5 W/so.ft. if this hex in rhnrkad FMv-eft m..,e he filled ...� ,.,w-.. �..�...u.�__ _ _ 1..0 11-I. Jllxe I EnergyPro 4.0 by EnergySoft User Number: 4582 Job Number: 05019 Page: 6 of 15 CERTIFICATE OF COMPLIANCE MECH-1-C PROJECT NAME DATE Madison Club Guardhouse Building B 10/13/2005 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-I-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates. and ooeratina and maintenance infnrmatinn meet the rPnLliPmPntS of RPrtinn in-•in'Arhi nnrl Title 7d Port r STATEMENT OF COMPLIANCE ❑ MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing " ❑ MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing ❑ MECH-4-A: Air Distribution Acceptance Document Equipment requiring acceptance testing ❑ MECH-5-A: Air -Side Economizer Acceptance Document Equipment requiring acceptance testing ❑ MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing ❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing ❑ MECH-8-A:-Hydronic System Control Acceptance Document -Variable Flow Controls -Automatic Isolation Con-trols -Water-loop Heat Pump Controls -Variable Frequency Controls Equipment requiring acceptance testing EnergyPro 4.0 by EnergySoft User Number: 4582 Job Number: 05019 Pagel of 15 AIR SYSTEM REQUIREMENTS - Part 1 of 2 MECH-2-C PROJECT NAME DATE Madison Club Guardhouse Building B 10/13/2005 SYSTEM FEATURES AIR SYSTEMS, Central or Sin le Zone ITEM OR SYSTEM TAG(S) FC/HP-a Number of Systems 1 T-24 MANDATORY MEASURES Section Reference on Plans or Specification Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance 112(a) 8.00 HSPF' 112 a 12.0 SEER / 10.0 EER 112(b) Yes 112(c), 115(a) n/a " 121(b) No - 121(b) 100 cfm 121 c No 121(c) No 121(c), 1220 Programmable Switch 122(e) Heating & Cooling Required 122 Gravity 122(g) n/a 123 124. R-8.0 144 a & b n/a 144 a & b 15,739 btuh _ 144 a & b n/a 144 a & b 18,796 btuh 144 U Constant Volume - 144 (c) 144 U No 144 U No 144 (, No Economizer 144(g.Constant Tem 144(f) Constant Temp 144 (k) No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column.. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sqft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. NATER SIDE SYSTEM REQUIREMENTS ' Part 2 of 2 MECH-2-C PROJECT NAME DATE Madison Club Guardhouse Building B 10/13/2005 SYSTEM FEATURES 2 WATER SIDE SYSTEMS: Chillers, Towers, Boilers, H dronic Loops ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Reference on Plans or Specification' Equipment Efficiency 112(a) Pipe Insulation 123 PRESCRIPTIVE MEASURES Calculated Capacity Proposed Capacity Tower Fan Controls Tower Flow Controls Variable Flow System Design Chiller and Boiler Isolation CHW and HHW Reset Controls WLHP Isolation Valves VSD on CHW, CW & WLHP Pumps > 5 HP DP Sensor Location 1: For each chiller, cooling tower, boiler, and hydronic loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A". in the column. 2: Water side systems include wet side system using other liquids such as glycol or brine. a Service Hot Water, Pool Heating ITEM OR SYSTEM TAG(S) DHW Heater Number of Systems 1 MANDATORY MEASURES Reference on Plans or Specification' Water Heater Certification 113 (a) Water Heater Efficiency 113 b Service Water Heating Installation 113 (c) Pool and Spa Efficiency and Control 114 a Pool and Spa Installation Pool Heater - No Pilot Light Ei' Spa Heater - No Pilot Light 1: For each water heater, pool heat and domestic water loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" ins the column. MECHANICAL VENTILATION MECH-3-C PROJECT NAME DATE Madison Club Guardhouse Building B 10/13/2005 PRESCRIPTIVE REHEAT LIMITATION (Section 144(d)) MECHANICAL VENTILATION Section 121 W2) AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C D E F G H I J K L M N ZONE/SYSTEM v°, T`°°• t!t ice.'• 0 CO) d� � `'°�3 T °o �'' 3 xDn 0 3 -n _" °' 3 Z two 3 Dm `° ° CD cCD tr moa xcn 'T1 'i1 --; 3 -a map exp O D 0 3t to D N o 0G) 0 3c� tp T. 'ztoBldg (� 3x° a0 x A O W3 d 0= O T?'" m :: � o3 3» P y D B 486 0.15 731 1 73 100 FC/HP-B Total 73 100 Minimum venilatio to per Section2 1. Table 121 -A E Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant load for egress purposes for spaces without fixed seating. H Required Ventilation Air (REO'D V.A.) is the larger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS (column D or G). I Must be greater than orequal to H or use Transfer Air column N to make up the difference. J Design fan supply dm Fan CFM) x 30%; or K Condition area fl. sq.) x 04 cfm/ft. sq. 4 or L Maximum of Columns H, J. K, or 300 cfm M This must be less than or equal to Column L and greater that or equal to the sum of Columns H + N. N Transfer air must be provided where the Required Ventilation Air (column H) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (column H) and the Design Minimum Air (column M), column H - M. EnergyPro 4.0 by EnergySoft User Number: 4582 Job Number: 05019 Page: 10 of 15 IMECHANICAL EQUIPMENT DETAILS Part 1 of 2 MECH-5-C PROJECT NAME Madison Club Guardhouse Building B DATE, 0/13/2005 CHILLER AND TOWER SUMMARY Energy Factor or RE Standby Loss or Pilot TANK INSUL. System Name System Type Distribution Type Efficiency Tons PUMPS Condition Status Equipment Name Equipment Type Qty. Tot. Qty GPM BHP Motor Eff. Drive Eff. Pump Control n/a n/a DHW / BOILER SUMMARY Hot Water P mp Hot Water Piping Length ft Add 1/2" Control # HP Type In Plenum Outside Buried Insulation CENTRAL SYSTEM RATINGS HEATING COOLING Aux. Condition System Name System Type Qty Output kW Eff. Output Efficiency Status Economizer Type York F3RPT030/E4FH030 Split DX 1 25,200 0 0.0 8.00 HSPF 23,500 12.0 SEER / 10.0 EER New No Economizer Energy Factor or RE Standby Loss or Pilot TANK INSUL. System Name System Type Distribution Type Qty Rated Input Vol. (Gals.) Condition Status Ext. R -Val. EWH-1 Chronomite 4160 w 08 v 0.5 pm Instant Elec Point of Use 1 14,197 0 New 0.98 n/a n/a Hot Water P mp Hot Water Piping Length ft Add 1/2" Control # HP Type In Plenum Outside Buried Insulation CENTRAL SYSTEM RATINGS HEATING COOLING Aux. Condition System Name System Type Qty Output kW Eff. Output Efficiency Status Economizer Type York F3RPT030/E4FH030 Split DX 1 25,200 0 0.0 8.00 HSPF 23,500 12.0 SEER / 10.0 EER New No Economizer MECHANICAL EQUIPMENT DETAILS Part 2 of 2 MECH-5-C PROJECT NAME M ZONE TERMINAI MARY Ilding B DATE,I VAV TERMINAL BOX TERMINAL FAN BASEBOARD Min. CFM R h Coil Motor Drive m Ty i _ T e DeltaT CFM BHP Eff. Eff. Type Output EXHAUST FAN EXHAUST FAN Room Name I Qty, I CFM BHP Motor Eff. Drive Eff. Room Name Qty_ CFM BHP Motor Eff. Drive Eff. Bldg B 1.0 1 10 0.17 60.00/c 97.0% ......... ........ .�MII vVMrr. 1 IG.7GJ`fLJJ EnergyPro 4.0 by EnergySoft User Number: 4582 Job Number: 05019 Pagel2 of 15 ENVELOPE MANDATORY MEASURES ENV -MM PROJECT NAME DATE Madison Club Guardhouse Building B 10/13/2005 DESCRIPTION Designer Enforcement §118(,) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article ` 3. 0 §118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. X] §117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). X] § 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U -value according to NFRC procedures. X❑ §118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls In nonresidential buildings shall have Insulation with an installed R -value of no less than R-11 between framing members. EneirgyPro By EnergySoft User Number: User Job Number: 05019 Page: 13 of 15 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM 77A ME DATE Madison Club Guardhouse Buildinq B 10/13/2005 DESCRIPTION i Designer Enforcement Equipment and Systems Efficiencies 0 §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. ❑ §115(a) Fan type central furnaces shall not have a pilot light. § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. a§ 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code.. Controls § 122(e) Each space conditioning system shall be installed with one of the following: X❑ § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or § 122(e)1 B An occupancy sensor to control the operating period of the system; or F§ 122(e)1C A 4 -hour timer that can be manually operated to control the operating period of the system. ❑ § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. ® § 122(a8:b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. X❑ § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. ❑ § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro By EnergySoft User Number: User Job Number: 05019 Page: 14 of 15 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM PROJECT NAME DATE Madison Club Guardhouse Building B ' 10/13/2005 Description Designer Enforcement Ventilation § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. - X❑ § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. § 122(o All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. § 121 (01 Air Balancing: The system shall be balanced In accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or § 121(02 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or § 121(03 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or § 121(f)4 Another method approved by the Commission. Service Water Heating Systems § 113(b)2 If a circulating hot water system is installed, It shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. § 113(b)3C Lavatories in restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system): Self-closing valves, and outlet devices that limit the flow of hot water to a maximum s of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). EnergyPro By EnergySoft User Number: User Job Number: 05019 Page:15 of 15 Certificate of Occupancy E y .t C� OF�ti Building Y p & Safety Department A This Certificate is issued pursuant to the requirements of Section 109 of the California Building ; Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and -the various ordinances of the City regulating building y construction and/or use. Y ? BUILDING ADDRESS: 52-120 MERIWETHER WAY Use classification: COMM Building Permit No.: 05-3825 W Occupancy Group: B Type of Construction: VN Land Use Zone: RL 1.44 Owner of Building: EAST OF MADISON, LLC Address: P.O. BOX 1482 '. City, ST, ZIP: LA QUINTA, CA 92247 e By: DAVID GATICA Date: NOVEMBER 15, 2006 Building Official POST IN A CONSPICUOUS PLACE s ry