Loading...
SFD (07-2077)t •, P.O. BOX 1504 ^' VOICE (760) 777-7012 . (i�� 4- 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT .«�.� Date: 7/17/07 Application Number: 1.07-00002077=_ Owner: Property. Address: 61790 MESA CT SHEA LA QUINTA APN: 764-280-999-63 —300237- C/O JEFF MCQUEEN Application description: DWELLING - SINGLE FAMILY DETACHED 8800 N GAINEY CE -5 Property Zoning: MEDIUM HIGH DENSITY RES SCOTTSDALE, AZ 8 8 n . Application valuation: 170639 Lr� Contractor: JUL 2 7 �a�7 Applicant: rchitect or Engineer: SHEA HOMES, INC. �CG� 81260 AVENUE 6 CIS W_ __ Cb LA QUINTA, CA 2253 FINANCOFLE QUINT4 (760)777-600S EDEP-r 1 Lic. No.: 672285 LICENSED CONTRACTOR'S DECLARATION I - WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Se ion 7000) Division 3 of the Business and Prof e io aIs Code, and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided ceso,G1s: L'cense No.: 672285 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is L 1 issued. Date. ontractor: I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier AMERICAN HOME Policy Number 1247619 following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any m�sose subje to the orkers' compensaonlaws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State nd agree that, ibiec o th wor rs' compensation p ovisions of SectionLicense Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business andProfessions Code) or 700 of t wi omp y wi ho pr visio that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: :pplicant:- " (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: the Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I—) I am exempt under Sec. BAP.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY . I hereby affirm under penalty of perjury that there is a construction lending agericy for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: P 1A .LQPERMIT APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work'being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. -icer fy that I h ve read this application and state that t Ove information is cor t. I agree to comply with all cRy y rdinances and state laws relating to ilding c ns- ctn; and herb au[horize representatives o thi c un y e upon the above-mentioned pro for insp ion urpose ` .Date: 16nature (Applicant or Agent): U LQPERMIT Application Number . . . . 07-00002077 Structure Information Construction Type . . TYPE V - NON RATED Occupancy Type._ DWELLG/LODGING/LONG <=10 Flood Zone . . . . . NON -AO FLOOD ZONE Other struct info .. CODE EDITION 2001 -CBC FIRE SPRINKLERS NO GARAGE SQ FTG 576.00 PATIO SQ FTG 177.00 NUMBER OF UNITS 1.00 ----------------------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 1943.00 Permit BUILDING PERMIT Additional desc . Permit Fee . . . 888.00 Plan Check Fee 144.30 Issue Date . . . . Valuation 170639 Expiration Date 1/13/08 �- Qty, Unit Charge, 'Per Extension BASE FEE 639.50 71.00 3.5000 THOU BLDG 100,001-500,000 248.50 Permit . . . MECHANICAL Additional desc . Permit Fee. .. . . . 70.50 Plan Check Fee 4.41 Issue Date . . . . Valuation 0 Expiration Date 1/13/08 Qty Unit Charge. Per Extension BASE FEE 15.00 2.00 9.0000 EA MECH FURNACE <=100K 18.00 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18:00 2.00 6.5000 EA MECH VENT FAN 13.00 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . . ELEC-NEW RESIDENTIAL- ESIDENTIALAdditional Additionaldesc . Permit Fee ' . 94.53 Plan Check Fee 5.91 Issue Date . . . . Valuation . . . 0 Expiration Date 1/13/08 Qty Unit Charge Per Extension BASE FEE 15.00 1943.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 68.01 576.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 11.52 v ' Application Number. 07-00002077 Permit PLUMBING _ Additional desc . Permit Fee 152.25 'Plan.Check Fee 8.95 Issue Date Valuation . . 0 1 Expiration Date 1/13/08 Qty Unit Charge Per Extension ' BASE FEE 15.00 14.00 6.0000 EA PLB FIXTURE 84.00 1.00 15.0000 EA PLB BUILDING SEWER .15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.5.0 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 5.00 .7500 EA PLB GAS PIPE >=5 3.75 1.00.. 15.0000 EA PLB GAS METER --------------- 15.00 Permit. ermit. . GRADING PERMIT Additional desc Permit Fee 15.00 Plan Check Fee .00 Issue Date Valuation 0 Expiration Date 1/13/08 Qty Unit Charge Per Extension BASE FEE 15.'00 Special Notes and Comments -SFD - LOT 63, PLAN 4520B, 1943 SF/ 255 SF CASITA,BOX BAY @ MBR -26 SF 4GARAGE EXT -.88 SF.PERMIT DOES NOT •INCLUDE BLOCK WALLS,POOL, SPA OR DRIVEWAY APPROACH. 75% REDUCTION TO PLAN CHECK FEE DUE TO MULTLIPLE ISSUANCE OF SAME PLAN TYPE. 2001 CBC; CMC, CPC, 2004' CEC,.2005 ENERGY CODES ---------------------------------------------------------------------------- Other Fees ... . . . . . . . ART IN PUBLIC PLACES -RES .00 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 995.00 ENERGY REVIEW.FEE 14.43 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE .00 _ DIF LIBRARIES - RES 355.00 DIF PARK MAINT - RES. 22.00 _FAC DIF PARKS/REC - RES. -892.00 STRONG MOTION (SMI) - RES 17.06 LQPERMIT Application.Number. 07-00002077 �. ----- - ------------------ , • - ---------- -- ----Other Other Fees DIF STREET MAINT'FAC-RES 67.00 - DIF TRANSPORTATION - RES 1930. 00 r' Fee summary Charged Paid Due '---------------- :•Credited Permit.Fee Total ---------- 1220.28 -------------------- `-".00 .00 ---------- 1220.28 _ - Plan Check Total. 163.57 00 .00 ,163.57 Other Fee Total 4506.49 '. .00 00 4506.49 ,. ` Grarid Total 5890.34 .00 .00 5890.34" . Y + . LQPERMIT °, " - JCM Inspections 39725 Garand Lane Suite F LT.hi'Palm Desert, CA 92211 LT.M.J INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS REINFORCED CONCRETE INSPECTION REPORT Dates: Noted Below Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: 60-800 Triolgy Parkway La Quinta, CA Client: Sub -Contractor: Shea La Quinta, LLC DCCCC General Contractor: Architect: Structural Engineer: Shea Homes for Active Adults Bassenian Lagoni Borm & Associates, Inc./ Suncoast Post Tensi Slump (inches): ,j , 0o Supplier: Superior Time Sampled: �','� to ,♦ Mix Design: D83625PTitle Time in Mixer (min.): "� Specified Strength (PSI): 4000 Water Added @ Jobsite (gals.): (' Addmixture: POZZ 322N Concrete Temperature (F): gj� Truck #: Ticket #:` S Zi` Ambient Air Temperature (F): Field ID Marking: Set A - 4 cylinders Q✓ IBC 24 Other: Unresolved Items: ❑ None E] See Below Location of Sample: s\nj ❑ No Samples Taken Description of Work Inspected: Phase 1% C.3 Lot#'l O(0 Product Plan L4S,;)I0 P__:1 1 C r,Z 1) Received mill certifications for rebar and tendons placed. 2) Typical exterior Footings including Garage Footings/Door (11,12,13/SD-1), Tie Beams (20/SD-1), Typical Interior Footings/Rib including step (15,18/SD-1), Seven Strand Tendons (4,10,12,13,16/SD-1), Simpson Strong Walls (24/SD-1), Anchor Bolts and Holdowns (6,7,8/SD-1), Pad Footings and additional rebar placed as per these details and as noted on `a `� 2o\ . r� , V' -)n o.c� i c� �o '_ c>_ C.y rt 0C1n 'V_; "„S"o',, �-. b0'L � "Z.\ P, \m C'P.,�'� cO�Do­%. Also, typical details 2, 3/SD-1 and Notes on SN -1 apply. Checked rebar for grade, size, placement, coverage and splices. Rebar and tendons were securely tied and supported off the earth. Accepted for concrete placement. 1) The placement of concrete for areas noted above except Garage Interior Footing and Slab on Grade. Total cubic yards placed: approx A mechanical vibrator was used to consolidate the concrete. Approved #4 rebar slab dowels were placed @ 18" o.c. 2) Molded 4 cylinders for compression tests with breaks at 7 days (1), 28 days (2) and one f6ir holding purposes. 1) The placement of concrete for Garage Interior Footings and Slab on Grade Total cubic yards placed: approx `t, Verified correct mix design. I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications -applicable building laws. Final report issued at project completion. Inspecto : Jack C. Millin ICC' Certification No: 0842216-49 Contractor's Representative: Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page I of JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS PRESTRESSED CONCRETE INSPECTION REPORT Date:`)—!y,(.)7 Project Name: Trilogy @ La Quinta - Shea Homes Project No: 02-1109 Project Address: 60-800 Triolgy Parkway City: La Quinta, CA Client: Sub -Contractor: Shea La Quinta, LLC Sun Coast Tensioning General Contractor: Architect: Structural Engineer: Shea Homes for Active Adults Bassenian Lagoni Borm & Associates, Inc./ Suncoast Post Tensi Size and Type of Tendons: 1/2" Diameter Seven Strand Stress -Relieved Tendons Jack Machine Calibration: Received Sheet from Sun Coast -Gage Pressure in psi to Machine Load in kips psi to 33.04 kips/33,000 lbs Calibration Date: Machine # Phase Lot# Product Plan, l ��., I C3 ��(l23 �ac�O �►`� (;�� 5�� ❑✓ IBC Title 24 Other: Unresolved Items: None ❑ See Below Description of Work Inspected: Actual Elongation (in) Specified Complies within 7% +/- of specified elongation. Lot # Location Tendons Elongation (in) Reference 1WSW. �-ri0(03 Yes No Ca'l ❑ it ❑ irl+n >'\� I �� I01'�' LAS ❑ `� n_ (� -2- t 9 ❑ Rr 1:1 3 El 2 El ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications -applicable building laws. Final report issued at project completion. . Inspector: Jack C. Millin �15C.C^Certification No: 0842216-89 Contractor's Representative: . Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page ' of JCM Inspections - 39725 Garand Lane Suite F LPalm Desert, CA 92211 1 _ INSPECTIONS Phone: 760-345-5554 -. Fax: 760-772-3895 INSPECTIONS COMPRESSION STRENGTH TEST RESULTS Client: Shea La Quinta, LLC Date: 12/3/07 r .- Project: Trilogy @ La Quinta - Shea Homes Project No: 02-1109 60-800 Triolgy Parkway La Quinta, CA 92253 Set ID Structure Age of Test -Compression Strength JCM ID Location Date Cast Cylinder ID (days) Y ) ' (psi) Set A Phase 18C3 - Lot # 7063 Slab on Grade 8-27-07 Concrete 273-923 Kitchen Required psi: 4000 8201 8 3750 8202 28 5140 8203. 28 5100 rN CERTIFIED: JCM Inspections supplies the service • of compression strength test results only. Per ASTMC39