SFD (07-2077)t
•, P.O. BOX 1504 ^' VOICE (760) 777-7012
. (i�� 4-
78-495 CALLE TAMPICO FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
.«�.� Date: 7/17/07
Application Number: 1.07-00002077=_ Owner:
Property. Address: 61790 MESA CT SHEA LA QUINTA
APN: 764-280-999-63 —300237- C/O JEFF MCQUEEN
Application description: DWELLING - SINGLE FAMILY DETACHED 8800 N GAINEY CE -5
Property Zoning: MEDIUM HIGH DENSITY RES SCOTTSDALE, AZ 8 8 n .
Application valuation: 170639 Lr�
Contractor: JUL 2 7 �a�7
Applicant: rchitect or Engineer: SHEA HOMES, INC.
�CG� 81260 AVENUE 6 CIS
W_ __ Cb LA QUINTA, CA 2253 FINANCOFLE QUINT4
(760)777-600S EDEP-r
1 Lic. No.: 672285
LICENSED CONTRACTOR'S DECLARATION I - WORKER'S COMPENSATION DECLARATION
hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations:
Se ion 7000) Division 3 of the Business and Prof e io aIs Code, and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
ceso,G1s: L'cense No.: 672285 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
L 1 issued.
Date. ontractor: I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
OWNER -BUILDER DECLARATION insurance carrier and policy number are:
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier AMERICAN HOME Policy Number 1247619
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any m�sose subje to the orkers' compensaonlaws of California,
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State nd agree that, ibiec o th wor rs' compensation p ovisions of SectionLicense Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business andProfessions Code) or 700 of t wi omp y wi ho pr visio
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: :pplicant:- "
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: the Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
I—) I am exempt under Sec. BAP.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY .
I hereby affirm under penalty of perjury that there is a construction lending agericy for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address: P 1A
.LQPERMIT
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work'being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
-icer fy that I h ve read this application and state that t Ove information is cor t. I agree to comply with all
cRy y rdinances and state laws relating to ilding c ns- ctn; and herb au[horize representatives
o thi c un y e upon the above-mentioned pro for insp ion urpose `
.Date: 16nature (Applicant or Agent): U
LQPERMIT
Application Number . . . . 07-00002077
Structure Information
Construction Type . . TYPE V - NON RATED
Occupancy Type._
DWELLG/LODGING/LONG <=10
Flood Zone
. .
. . . NON -AO FLOOD ZONE
Other struct info
.. CODE EDITION 2001 -CBC
FIRE SPRINKLERS NO
GARAGE SQ FTG
576.00
PATIO SQ FTG
177.00
NUMBER OF UNITS
1.00
-----------------------------------------------------------------------------
1ST FLOOR SQUARE FOOTAGE
1943.00
Permit
BUILDING PERMIT
Additional desc
.
Permit Fee . .
.
888.00 Plan Check Fee
144.30
Issue Date . .
. .
Valuation
170639
Expiration Date
1/13/08 �-
Qty, Unit
Charge,
'Per
Extension
BASE FEE
639.50
71.00
3.5000
THOU BLDG 100,001-500,000
248.50
Permit .
. . MECHANICAL
Additional desc
.
Permit Fee. .. .
. .
70.50 Plan Check Fee
4.41
Issue Date . .
. .
Valuation
0
Expiration Date
1/13/08
Qty Unit
Charge.
Per
Extension
BASE FEE
15.00
2.00
9.0000
EA MECH FURNACE <=100K
18.00
2.00
9.0000
EA MECH B/C <=3HP/100K BTU
18:00
2.00
6.5000
EA MECH VENT FAN
13.00
1.00
6.5000
EA MECH EXHAUST HOOD
6.50
Permit .
. . ELEC-NEW RESIDENTIAL-
ESIDENTIALAdditional
Additionaldesc
.
Permit Fee ' .
94.53 Plan Check Fee
5.91
Issue Date . .
. .
Valuation . . .
0
Expiration Date
1/13/08
Qty Unit
Charge
Per
Extension
BASE FEE
15.00
1943.00
.0350
ELEC NEW RES - 1 OR 2 FAMILY
68.01
576.00
.0200
ELEC GARAGE OR NON-RESIDENTIAL
11.52
v
' Application Number. 07-00002077
Permit PLUMBING
_
Additional desc .
Permit Fee 152.25 'Plan.Check Fee
8.95
Issue Date Valuation . .
0 1
Expiration Date 1/13/08
Qty Unit Charge Per
Extension
' BASE FEE
15.00
14.00 6.0000 EA PLB FIXTURE
84.00
1.00 15.0000 EA PLB BUILDING SEWER
.15.00
1.00 7.5000 EA PLB WATER HEATER/VENT
7.5.0
1.00 3.0000 EA PLB WATER INST/ALT/REP
3.00
1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM
9.00
5.00 .7500 EA PLB GAS PIPE >=5
3.75
1.00.. 15.0000 EA PLB GAS METER
---------------
15.00
Permit.
ermit. . GRADING PERMIT
Additional desc
Permit Fee 15.00 Plan Check Fee
.00
Issue Date Valuation
0
Expiration Date 1/13/08
Qty Unit Charge Per
Extension
BASE FEE
15.'00
Special Notes and Comments
-SFD - LOT 63, PLAN 4520B, 1943 SF/ 255
SF CASITA,BOX BAY @ MBR -26 SF 4GARAGE
EXT -.88 SF.PERMIT DOES NOT •INCLUDE
BLOCK WALLS,POOL, SPA OR DRIVEWAY
APPROACH. 75% REDUCTION TO PLAN CHECK
FEE DUE TO MULTLIPLE ISSUANCE OF SAME
PLAN TYPE. 2001 CBC; CMC, CPC, 2004'
CEC,.2005 ENERGY CODES
----------------------------------------------------------------------------
Other Fees ... . . . . . . . ART IN PUBLIC PLACES -RES
.00
DIF COMMUNITY CENTERS -RES
74.00
DIF CIVIC CENTER - RES
995.00
ENERGY REVIEW.FEE
14.43
DIF FIRE PROTECTION -RES
140.00
GRADING PLAN CHECK FEE
.00 _
DIF LIBRARIES - RES
355.00
DIF PARK MAINT - RES.
22.00
_FAC
DIF PARKS/REC - RES.
-892.00
STRONG MOTION (SMI) - RES
17.06
LQPERMIT
Application.Number.
07-00002077
�.
----- - ------------------ ,
•
- ----------
-- ----Other
Other Fees
DIF STREET MAINT'FAC-RES
67.00 -
DIF TRANSPORTATION - RES
1930. 00
r' Fee summary
Charged
Paid
Due
'----------------
:•Credited
Permit.Fee Total
----------
1220.28
--------------------
`-".00 .00
----------
1220.28 _
- Plan Check Total.
163.57
00 .00
,163.57
Other Fee Total
4506.49
'. .00 00
4506.49 ,.
` Grarid Total
5890.34
.00 .00
5890.34" .
Y
+ .
LQPERMIT °, " -
JCM Inspections
39725 Garand Lane Suite F
LT.hi'Palm Desert, CA 92211 LT.M.J
INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS
REINFORCED CONCRETE INSPECTION REPORT Dates: Noted Below
Project Name: Project No:
Trilogy @ La Quinta - Shea Homes 02-1109
Project Address: City:
60-800 Triolgy Parkway La Quinta, CA
Client: Sub -Contractor:
Shea La Quinta, LLC DCCCC
General Contractor: Architect: Structural Engineer:
Shea Homes for Active Adults Bassenian Lagoni Borm & Associates, Inc./ Suncoast Post Tensi
Slump (inches): ,j , 0o Supplier: Superior
Time Sampled: �','� to ,♦ Mix Design: D83625PTitle
Time in Mixer (min.): "� Specified Strength (PSI): 4000
Water Added @ Jobsite (gals.): (' Addmixture: POZZ 322N
Concrete Temperature (F): gj� Truck #: Ticket #:` S Zi`
Ambient Air Temperature (F): Field ID Marking: Set A - 4 cylinders
Q✓ IBC
24
Other:
Unresolved Items:
❑ None
E] See Below
Location of Sample: s\nj
❑ No Samples Taken
Description of Work Inspected: Phase 1% C.3 Lot#'l O(0 Product Plan L4S,;)I0 P__:1
1 C r,Z
1) Received mill certifications for rebar and tendons placed.
2) Typical exterior Footings including Garage Footings/Door (11,12,13/SD-1), Tie Beams (20/SD-1), Typical Interior Footings/Rib including step (15,18/SD-1),
Seven Strand Tendons (4,10,12,13,16/SD-1), Simpson Strong Walls (24/SD-1), Anchor Bolts and Holdowns (6,7,8/SD-1), Pad Footings and additional
rebar placed as per these details and as noted on `a `� 2o\ . r� , V' -)n o.c� i c� �o '_ c>_ C.y rt 0C1n
'V_; "„S"o',, �-. b0'L � "Z.\ P, \m C'P.,�'� cO�Do%.
Also, typical details 2, 3/SD-1 and Notes on SN -1 apply. Checked rebar for grade, size, placement, coverage and splices. Rebar and tendons were
securely tied and supported off the earth. Accepted for concrete placement.
1) The placement of concrete for areas noted above except Garage Interior Footing and Slab on Grade. Total cubic yards placed: approx
A mechanical vibrator was used to consolidate the concrete. Approved #4 rebar slab dowels were placed @ 18" o.c.
2) Molded 4 cylinders for compression tests with breaks at 7 days (1), 28 days (2) and one f6ir holding purposes.
1) The placement of concrete for Garage Interior Footings and Slab on Grade Total cubic yards placed: approx `t, Verified correct mix design.
I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved
plans, specifications -applicable building laws. Final report issued at project completion.
Inspecto : Jack C. Millin ICC' Certification No: 0842216-49
Contractor's Representative:
Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page I of
JCM Inspections
39725 Garand Lane Suite F
Palm Desert, CA 92211
INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895
INSPECTIONS
PRESTRESSED CONCRETE INSPECTION REPORT Date:`)—!y,(.)7
Project Name:
Trilogy @ La Quinta - Shea Homes
Project No:
02-1109
Project Address:
60-800 Triolgy Parkway
City:
La Quinta, CA
Client: Sub -Contractor:
Shea La Quinta, LLC Sun Coast Tensioning
General Contractor: Architect: Structural Engineer:
Shea Homes for Active Adults Bassenian Lagoni Borm & Associates, Inc./ Suncoast Post Tensi
Size and Type of Tendons: 1/2" Diameter Seven Strand Stress -Relieved Tendons
Jack Machine Calibration: Received Sheet from Sun Coast -Gage Pressure in psi to Machine Load in kips
psi to 33.04 kips/33,000 lbs
Calibration Date: Machine #
Phase Lot# Product Plan, l ��.,
I C3 ��(l23 �ac�O �►`� (;�� 5��
❑✓ IBC
Title 24
Other:
Unresolved Items:
None
❑ See Below
Description of Work Inspected: Actual Elongation (in)
Specified Complies within 7% +/- of specified elongation.
Lot # Location Tendons Elongation (in) Reference 1WSW.
�-ri0(03
Yes No
Ca'l
❑
it
❑
irl+n >'\�
I
��
I01'�'
LAS ❑
`�
n_
(�
-2- t
9 ❑
Rr 1:1
3
El
2 El
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved
plans, specifications -applicable building laws. Final report issued at project completion. .
Inspector: Jack C. Millin �15C.C^Certification No: 0842216-89
Contractor's Representative:
. Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page ' of
JCM Inspections -
39725 Garand Lane Suite F
LPalm Desert, CA 92211 1 _
INSPECTIONS Phone: 760-345-5554 -. Fax: 760-772-3895 INSPECTIONS
COMPRESSION STRENGTH TEST RESULTS
Client: Shea La Quinta, LLC Date: 12/3/07
r .-
Project: Trilogy @ La Quinta - Shea Homes Project No: 02-1109
60-800 Triolgy Parkway
La Quinta, CA 92253
Set ID Structure Age of Test -Compression Strength
JCM ID Location Date Cast Cylinder ID (days) Y ) ' (psi)
Set A Phase 18C3 - Lot # 7063 Slab on Grade 8-27-07 Concrete
273-923 Kitchen Required psi: 4000
8201 8 3750
8202 28 5140
8203. 28 5100
rN
CERTIFIED:
JCM Inspections supplies the service
• of compression strength test results only.
Per ASTMC39