Loading...
BPOL2014-104878-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: TESERRA PO BOX 1280 COACHELLA, CA 92236 c&t1t 4 4v Qum& COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT BPOL2014-1048 58480 WAS 764620016 POOL SPA BBQ AND FIRE PIT AUG 2 7 2014 CITY OF LA QUINTA COMMUNITY DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C-8, C27, C10, C29, C53 License No.: 656128 Date: �02 Contract OWNER -BUIL ER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permitsubjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's VOICE (760) 777-7125 .FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 8/27/2014 Owner: AMARAL 58480 MIJAS LA QUINTA, CA 92253 Contractor: TESERRA PO BOX 1280 COACHELLA, CA 92236 (760)398-9222 Llc. No.: 656128 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the we for which this permit is issued. I have and will maintain workers' compensation insurance, as required by 5e ion 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: 1� , hxl_Applicant: WARNING: FAILURE TO SECURE WORK COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned p operty f r inspection purposes. Date: �� Signature (Applicant or Agent): FINANCIAL • ' • DESCRIPTION=`ACCOUNT, `' 'QTY AMOUNT PAID PAID DATE DEVICES, FIRST 20 101-0000-42403 0 $23.83 $0.00 'PAID BY ," '. METHOD f RECEIPT # CHECK # CLTD BY DESCRIPTION',' ACCOUNT..: QTY AMOUNT - ., PAID PAID DATE DEVICES, FIRST 20 PC 101-0000-42600 0 $23.83 $0.00 'PAID.BY . a:, ,, METHOD RECEIPT # CHECK # "CLTD BY Total Paid for ELECTRICAL: $47.66 $0.00 DESCRIPTION " ', .°ACCOUNT' QTY ,. AMOUNT PAID PAID DATE GAS SYSTEM, 1-4 OUTLETS 101-0000-42401 0 $11.92 $0.00 PAID BY ' METHOD. ' r, - , '::RECEIPT # CHECK # , CLTD BY DESCRIPTION . " ' 'ACCOUNT QTY " AMOUNT PAID PAID DATE GAS SYSTEM, 1-4 OUTLETS PC 101-0000-42600 0 $23.83 $0.00 - PAID BY t` . 'METHOD RECEIPT # CHECK # r CLTD BY Total Paid for PLUMBING FEES: $35.75 $0.00 r,-! DESCRIPTION :•'. - .a w ACCOUNT 'CITY! -AMOUNT ' , PAID PAID DATE SWIMMING POOL/SPA 101-0000-42404 0 $178.75 $0.00 PAID BY ; - .:� ., , METHOD RECEIPT # CHECK # ` CLTD BY- YDESCRIPTION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE SWIMMING POOL/SPA PC 101-0000-42600 0 $97.24 $0.00 PAID BY ' ' METHOD "'''RECEIPT # CHECK # '. CLTD BY - Total Paid forPOOL / SPA: $275.99 $0.00 TOTALS:• $0.00 4 Erg I Q- I Permit Details . PERMITUMBER ` City of L'a Quinta BPOL2014-1048 Description: POOL SPA BBQ AND FIRE PIT Type: POOL Subtype: Status: APPROVED Applied: 8/27/2014 MFA Approved: • . Parcel No: 764620016 Site Address: 58480 MIJAS LA QUINTA,CA 92253 Subdivision: TR 31681-2 Block: Lot: 64 - Issued: Lot Scl Ft: 0 Building Scl Ft: 0 Zoning: Finaled: Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 FAX -. EMAIL Details: POOL, SPA, FIRE PIT, AND BBQ [2 INCH GAS PIPING/#8 AWG IN 1 INCH CONDUIT ELECTRICAL] THIS PERMIT DOES NOT INCLUDE EQUPMENT WALL. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE -PLASTER INSPECTION. 2013 CALIFORNIA BUILDING CODE. ADDITIONAL SITES "_ t+ CHRONOLOGY w CLTD . DESCRIPTION ACCOUNT QTY AMOUNT PAID 'PAID DATE RECEIPT.# CHECK # METHOD PAID BY BY DEVICES, FIRST 20 101-0000-42403 0 $23.83 $0.00 DEVICES, FIRST 20 PC 101-0000-42600 0 $23.83 $0.00 Total Paid for ELECTRICAL: $47.66- $0.00 ' Printed: Wednesday, August 27, 2014 8:55:24 AM 1 of 2 C SYSTEMS NAME TYPE '` •NAME ' _ .. CONTACTS " ADDRESS1 ' ` t r CITY- STATE : ZIP - PHONE ' FAX -. EMAIL APPLICANT TESERRA PO BOX 1280 COACHELLA CA 92236 .CONTRACTOR TESERRA PO BOX 1280 rCOACHELLA CA 92236 OWNER AMARAL 58480 MIJAS LA QUINTA CA 92253 CLTD . DESCRIPTION ACCOUNT QTY AMOUNT PAID 'PAID DATE RECEIPT.# CHECK # METHOD PAID BY BY DEVICES, FIRST 20 101-0000-42403 0 $23.83 $0.00 DEVICES, FIRST 20 PC 101-0000-42600 0 $23.83 $0.00 Total Paid for ELECTRICAL: $47.66- $0.00 ' Printed: Wednesday, August 27, 2014 8:55:24 AM 1 of 2 C SYSTEMS ' :DESCRIPTION �; ACCOUNT" QTY AMOUNT ""_ PAID PAID DATE, RECEIPT#• 'CHECK# METHOD PAID BY' „` .BY ti's GAS SYSTEM, 14 101-0000-42401 • 0 $11.92 $0.00 OUTLETS GAS SYSTEM, 1-4 101-0000-42600 0 $23.83 $0.00 OUTLETS PC Total Paid for PLUMBING FEES: $35.75 $0.00 SWIMMING POOL/SPA 1017-0000-42404 0 $178.75 .$0.00 SWIMMING POOL/SPA 101-0000-42600 0 $97.24 $0.00 t PC Total Paid for POOL / SPA: $275.99 $0.00 TOTALS:1 $0.00 r"` a1: ,3 r -i INSPECTIONS�:. jtSEQID�[SCHEDULED INSPECTION TYPE ' INSPECTOR COMPLETED RESULT :.`REMARKS ' NOTES_.�. DATE � DATE 1 :'A PARENT PROJECTS REVIEWSn `^i F RETURNED' STATUS REVIEW TYPE REVIEWER SENT DATE` * DUE DATE DATf_ aREMARKS 4 NOTES ' - NON-STRUCTURAL AJ ORTEGA 8/27/2014 8/27/2014 8/27/2014 APPROVED :• • INFORMATION 1p Printed: Wednesday, August 27, 2014 8:55:24 AM 2 of 2 0 ; SYSTEMS BELGARD CATALINA 3 PIECE LARGE PAVER DECKING SAND SET OVER 4" OF COMPACTED ROAD BASE AND 1"OF BEDDING SAND, POLYMERIC SAND GROUT, MAID SET PAVER SOLDIER COURSE (CiOLOR: 'MONTECITO') POOL / SPA LIGHT JUNCTION BOX POOL / BRA LIGHT ON GROUND FAULT CIRCUIT INTERRUPTER i IN POOL EQUIPMENT 50 AMP SUBPANEL WITH 30" CLEARANCE AT FRONT AND SIDE l 421 SQ.FT. ACID WASH FINISH CONCRETE COPING /PADS rAm POOL EQUIPMENT: 400,000 BTU HEATER SURFACE AREA OF POOL ONLY s+e saFT PERIMETER 122 I N FT DEPTHS MIN 8'4e' • NO EXISTING LANDSCAPE LIGHTING IN REAR YARD I3 POOL 8 SPA COMBINED "-"" Bn.R- / 14D W.Ff. — • NO EXISTING OVERHEAD UTILITY LINES IN REAR YARD SPA SPECIFICATIONS TILE • PATIO FURNITURE FOR ILLUSTRATION PURPOSES ONLY SIO:AAr XZABO. FT. 66 I.N. FT. 30 I I POOL SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART. I F-11" ANTI -COVERS 10"ASME / ANSI APPROVED QUARTER ROUND STEPS PROP. EXT. WALLS= OIAHTRVMLL — TANNING SHELF AT 16" WATER DEPTH R.B.B. TILE RAISEDSPAAT WITH ONE UMBRELLA SLEEVE 2) PAVER ECKING SIR PANEL WITH PURE WAND AQUA PALM SPA SPLIT MAIN DRAIN SUCTION MINIMUM V APART. ANTI -COVERS 10" ASME / ANSI APPROVED SPA AT 0" WITH TILE DAM WALL, 6 JETS AT ALTERNATE HEIGHTS HOSE BIB BELGARD CATALINA 3 PIECE LARGE PAVER DECKING SAND SET OVER 4" OF COMPACTED ROAD BASE AND 1"OF BEDDING SAND, POLYMERIC SAND GROUT, MAID SET PAVER SOLDIER COURSE (CiOLOR: 'MONTECITO') POOL / SPA LIGHT JUNCTION BOX POOL / BRA LIGHT ON GROUND FAULT CIRCUIT INTERRUPTER i IN POOL EQUIPMENT 50 AMP SUBPANEL WITH 30" CLEARANCE AT FRONT AND SIDE MAIN HOUSE 200 AMP ELECTRICAL PANEL INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL COMPLY WITH SECTION 114 - MANDATORY REQUIREMENTS EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS TO THE POOL POOL HEATERS / PUMP EQUIPMENT SHALL BE INSTALLED PER MANU FACTURER'S RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS ALL DECKING EXPANSION JOINTS FOR REPRESENTAION ONLY, FIELD LAYOUT WILL VARY w;! POOL NTH TILE WATERLINE AND PEBBLE TEC FINISH T-640 PS PB FIVE JANDY DECK JET EMITTERS WITH DEDICATED PUMP AND PLUMBING ACID WASH FINISH COLORED CONCRETE COPING AROUND POOL ONLY (COLOR: 'SEQUOIA SAND') l 421 SQ.FT. ACID WASH FINISH CONCRETE COPING /PADS rAm POOL EQUIPMENT: 400,000 BTU HEATER SURFACE AREA OF POOL ONLY s+e saFT PERIMETER 122 I N FT DEPTHS MIN 8'4e' "ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED I3 POOL 8 SPA COMBINED "-"" Bn.R- / 14D W.Ff. — IRRIGTX7N SEMINAL BY NRIGTIOH rEPAILi r R.BB. — FT (rR.B.B. — FT SPA SPECIFICATIONS TILE ELECTRIC CONDUIT SIO:AAr XZABO. FT. 66 I.N. FT. 30 =.rfi1E WATLOTLLI E 8'x8" TILE VW i � � F-11" SB. QUARTER ROUND STEPS PROP. EXT. WALLS= OIAHTRVMLL — 173' - 2" POLYPROPYLENE GAS PIPE R.B.B. TILE RAISEDSPAAT TIL s. MAIN HOUSE 200 AMP ELECTRICAL PANEL INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL COMPLY WITH SECTION 114 - MANDATORY REQUIREMENTS EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS TO THE POOL POOL HEATERS / PUMP EQUIPMENT SHALL BE INSTALLED PER MANU FACTURER'S RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS ALL DECKING EXPANSION JOINTS FOR REPRESENTAION ONLY, FIELD LAYOUT WILL VARY w;! POOL NTH TILE WATERLINE AND PEBBLE TEC FINISH T-640 PS PB FIVE JANDY DECK JET EMITTERS WITH DEDICATED PUMP AND PLUMBING ACID WASH FINISH COLORED CONCRETE COPING AROUND POOL ONLY (COLOR: 'SEQUOIA SAND') T 3"S w�l +3" 4 SPECIFICATIONS 421 SQ.FT. ACID WASH FINISH CONCRETE COPING /PADS r.I 1I SUPE MITE SIZE M'� 987 SQ.FT, RIO BLEND CATALINA PAVER DECKING I SURFACE AREA OF POOL ONLY s+e saFT PERIMETER 122 I N FT DEPTHS MIN 8'4e' CANnEvel TO SIDE _ °OORA"_ � BhTB — STEP POOL 8 SPA COMBINED "-"" Bn.R- / 14D W.Ff. — IRRIGTX7N SEMINAL BY NRIGTIOH rEPAILi r R.BB. — FT (rR.B.B. — FT SPA SPECIFICATIONS TILE — 1CR.B.S. El SIO:AAr XZABO. FT. 66 I.N. FT. 30 =.rfi1E WATLOTLLI E 8'x8" TILE VW SPADAMWALLWI I2" TU:TRIM TAH8MELFDEPTI Te• WD ROCK POC��a CENTERS NO. OF 8 QUARTER ROUND STEPS PROP. EXT. WALLS= OIAHTRVMLL — LNM 1-1DOW R.B.B. TILE RAISEDSPAAT TIME MOCK DANDY RSB ONE TOUCH 2) PAVER ECKING T 3"S w�l +3" 4 FIREPIT AT +9" WITH ACID WASH FINISH COLORED CONCRETE CAP AND TILE VENEER FACE }" TO 1" BRONZE GLASS MEDIA POURED CONCRETE COUNTERTOP WITH 3" DROP EDGE AT +36"WITH 36" ALx2 ALFRESCO BARBECUE, 36" STAINLESS STEEL SINGLE DOORIDOUBLE DRAWER COMBO, STUCCO EXTERIOR TO MATCH HOUSE EXCAV T N STEEL TYPE STREET SM FT, MTsM RMSH ACID WASH EXPANSIONJOINIM YE Y E � DEEP EwRAMP LOVE SEAT SW RECONCRTE � gODREICN/J. AaREQI1IRED TREE REMOVAL BY WA CANnEvel TO SIDE _ °OORA"_ � BhTB — STEP SIB FACE VES AT El IRRIGTX7N SEMINAL BY NRIGTIOH rEPAILi r R.BB. — FT (rR.B.B. — FT TILE BAEE — BA DANDVISO EEN 9 RIBBONS NO MOWQIRP 1'19 — 1CR.B.S. El INC x1 REBAR 18" o. 24'RBB — WR." — FT 2013 CALIFORNIA ENERGY EFFICIENCY STANDARDS7 TAH8MELFDEPTI Te• WD ROCK POC��a CENTERS MASONRY COPING T.cA= RBEI.FACING — SPILLWAY TYPE PLUMBING FILTER JANDY SEE 880 S(XFT. FOCI. pU,KPJANDY S(¢ BOOSTER PUMP= SIZE — DISQ(JE'T RILIPJANDY BI2E P ___ _ ITER JANDY U(I 8M 40D.000 BTU 1 STEPS PROP. EXT. WALLS= OIAHTRVMLL — RETANING WALL" = EQUIP. W AUuB — FIREPIT YES PERPLA 1)EARBECUE PER Po TIME MOCK DANDY RSB ONE TOUCH 2) PAVER ECKING SIR PANEL WITH PURE WAND AQUA PALM CITY OF LA QUINTA BUILDING & SAFE 1 Y DEPT. APPROVEki FOR CONSTRUCTION DATE BY OVERFLOWING POT WATERFEATURE WITH SUBMERSIBLE PUMP, COBBLE NBCi OVERLAY, INTERMATIC TIME CLOCK od - - - (3 -240 -GREEN) EXISTING CONCRETE WALKWAY TO REMAIN i GIS LINE F.M. STABS. FOUNTAINS I SPRAYHEPDS PRE I SHEEROESCENIS — LIG TS IN POOL L- 1=0 IN GATE.. GUNITE' GATE REVERSAL DEEP ED RAMP— REMOVE S REHAMi rF3 EXTEND Intl STEP — LOVESEAT YES SPILLWAY TYPE I— n AFrr CANTILEVER NO anP�moN COPING OTHER pURELINK STILT SYSTEM R.B.B.-BEE STEEL AQUA REMOTE OWNER RESPONSIBILITIES OWNER r0:. (1) DETERMINE THE APIRdOMATE ELEVATION OF POOL ON SPA AT LAYOUT ON MY OF VIOWAYION. BL.=T1 C L TD�ARTENTAr . �fAaPFfMfro ACCtFfNICE GAF (S) WET DOM CONCRETE SLEILAT LEM TTYLICE DAILY FORSEVEI QAYSAFTER 81MlL M SRTALUM (A AGREETMIAr TESERRAMxor aE IORISQERWDI/DCOIDnDNSOROSECTB. ANDANYLLIMAOETOCtlel S�DANEWRYB.IAWNBOROBERDEMENTIEACCE88ARFA (MiROrTP�N9'IA�DER MOPE ME WAGE DOORS MKLO T LOCALCOM FORAPOOL ENCSURE M)FILLPOOLORMAYAFTER PLASIEL(FIXIdYNeIAUCTKINB-WNOT USE RUBBER HOSE) M TAKE NOICEER oFS�KEflMMMHEPFtSOLRFPROPE➢e LAW OF TKERRA ANO TJATANY USE jAMMIT vaT MIFOR: AMARAL RESIDENCE E SCALE I DATE I DESIGNED BY PROJECT MGR EGICEO Y i"= 1' 08-05-14 JT. JH. MB PAUL Y. 9 J08*I REVISIONS ' ALL AHTENTRAPMEMCMEX INSTALLATION MEETING CURRENT BTANDARDSOF THE AMEMCM 80CMTY FOR TESTING AND MATERIALS OR THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (AEE) ELECTRICAL: EQUIPOTENTAL BOWING REQUIREMENTS SHAD. BE INSTALLED TO EUMINATE VOLTAGE 3 /E (55 GRADIENTS IN THE POOL AREA AS PER CEC ART. SDTB. Z0) 3 CALIFORNIA BUILDING CODE (BASEDON2008I9C) ZO 13 CALIFORNIA MECHANICAL CODE (SABEOON2DOBUMC) Z 0 13 CALIFORNIA PLUMBING CODE (BABEDON2009UPC)—.— ZO 13 CALIFORNIA ELECTRICAL CODE (BASEDON2008NEc)16 2013 CALIFORNIA ENERGY EFFICIENCY STANDARDS7 _..- ._..__..._'. --.. IXGVATOfUANDF AREIXGVATORXCA,A UL aB.BFATENMTIMa1E OTHER SURABLEM ARE TO.BEIXGVAIED CONSTRUCTION AUTHORIZATION 11 SALES FIELD SELECTIONS 15CK COLOR TOQUE 677 ANDY RS6 JANDY'ONE TOUCH' IEBBIPLAS PEBBLE TEC CARIBBEAN BLUE AGNATURE DRAINAGE NOTE: Drahupe and h OOm for ph ftm end Pte, 011 ohn, unim oBIBLWIin noted. .o . Iain # City ®f La Quinta Building 8L Safety Division Permit # P.O. Box 1504, 78-495 Calfe Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Project Address: Owner's Name: A. P. Number: Address: Legal Description: City, ST, Zip: Contractor: Telephone: Plan Check submitted Address: x�110d 6n� Project Description: City, ST, Zip: TeleP hone: a State Lic. # : City Lie. #: Arch., Engr., Designer: Plan Check Deposit Address: City., ST, Zip: Telephone: >: State Lie. #: 'z<:•::::::::<;::.:;::.;:.::;:;•>::;.<:;.;><.;>< Name of Contact Person: VAC �y �/ Construction T e: Occupancy: YP P Y: Project e J type (circle one): New Add'n Alter Repair Demo Sq. Ft.: # Stories: # Units: Telephone #,of Contact Person: Estimated Value of Project: APPLICANT: DO NOT WRITE RR OW THIR I IMF # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Cales. Called Contact Pcrson• Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2od Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted ` Grading IN HOUSE: 3d Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person, A.I.P.P. Pub. Wks. Appr Date of permit issue Schodl Fees Total. Permit Fees