AR (11-0775).4
P.O. BOX 1504 VOICE (760) 777-7012
78-495 CALLE TAMPICO FAX (760) 777-7011
LA Q.UINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 1/ 12 / 12',
Application Number: cT1=00000775_. Owner:
Property Address: 80125 MIRAMONTE LN PLAM KENNETH H & SHIRLEY R
APN: 772-250-018-19 -31349.- 80125 MIRAMONTE LN
Application description: ADDITION - RESIDENTIAL LA QUINTA, CA 92253
Property Zoning: LOW-DENSITY RESIDENTIAL O
Application valuation: 40000
F 6 -
Contractor: JAN � ! 2012
Applicant: Architect or Engineer: SCHLICHT CONSTRUCTION'.
.80207 MARAMAR DRIVE I �1 -----�����pA
BERMUDA DUNES, CA 9223 �!ll.f�it+� �:r7
(760)702-1048
Lic. No.: 901161
------------------
LICENSED CONTRACTOR'S.DECLARATION
I hereby affirm under penalty of perjury that 1 am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: B License No.: 901161
ate:l L �— ntractor:
OWNER -BUILDER DECLARATION
I hereby affirmunder penalty of perjury that I am exempt from the Contractor's State License Law for the
,following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct,. alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter.9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
-
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.). _
(_ 1 I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY -
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: l� A '
Lender's Address: 1� ' -
LQPERMIT
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations: '
_ .I have and will maintain a certificateof consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation .
insurance carrier and policy number are:
Carrier E4EMPT Policy Number EXEMPT
certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California, '
and agree that, if I should become subject to the workers' compensation provisions of Section
3700 of the Labor Code, I shall forthwith comply with those provisions.
/` '�
DaEe: lie cant:
/WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL .
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FDA IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. .,
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application, _
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit. "
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation.of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and, hereby authorize representatives
of thi county to enter upon the above-mentioned property or inspecti urposes.
L Z S' ature (Applicant or Agent): '
Application Number . . . 11-00000775
------ Structure Information 428SF ADDITION/VB/RES-3/CLASS A -FR
[ENG] -----
Other struct info . .
. . . CODE EDITION 2010
FLOOD ZONE no
GARAGE SQ FTG
96.00
1ST FLOOR SQUARE FOOTAGE
428.00
Permit . . .
BUILDING PERMIT
Additional desc .
Permit Fee
349.50 Plan Check Fee
227.18
Issue Date . . ...
Valuation . . .
40000
Expiration Date
7/10/12
Qty Unit Charge
Per
Extension
BASE FEE
252.00
15.00 6.5000
-----------------------------------------------------------------------------
THOU BLDG 25,001-50,000
97.50
Permit . . . •ELECT
- ADD/ALT/REM
Additional desc .
Permit Fee
31.90 Plan Check Fee '.
7.98
Issue Date
Valuation . . .
0
Expiration Date
7/10/12
Qty. Unit Charge
Per*
Extension.
BASE FEE
15.00
428.00 .0350
ELEC NEW RES - 1 OR 2 FAMILY
14.98
96.00 .0200
----------------------------------------------------------------------------
ELEC.GARAGE OR NON-RESIDENTIAL
1.92
Permit MECHANICAL
Additional desc
Permit Fee . . . .
19.50 Plan Check Fee
4.88
Issue Date . . . .
Valuation
0
Expiration Date ,.
7/10/12
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1.00' 4.5000
EA MECH VENT INST/ DUCT ALT
4.50
Special Notes and Comments
428SF.FAMILY ROOM AND
96SF STORAGE. ROOM
ADDITION/VB/RES-3/CLASS A [ENGINEERED]
THIS PERMIT DOES NOT
INCLUDE RELOCATION
OF MECHANICAL HVAC OR.
POOL EQUIPMENT, OR
BLOCKWALLS. 2010 CALIFORNIA BUILDING
CODES.
LQPERMIT
LQPERAIIT
Application Number
. . . .
11=00000775
----------------------------------------------------------------------
Special Notes and
Comments
-October 12, 2011-3:39:36,PM
AORTEGA FOR
BRANADA
-----------------_-_----------------------------------------------------
Other Fees .'.
. . . . .
BLDG STDS ADMIN (SB1'473)
---
2.00
ENERGY REVIEW
FEE
22.72
STRONG MOTION
(SMI) - RES
.50
Fee summary
Charged
Paid Credited
Due
Permit Fee Total
.400.90
00
.00
400.90
Plan Check Total.
240.04
.00
00
240.04
Other Fee Total
25.22
.00
.00
25..22
Grand Total
666.16
.00
.00
666.16
CITY OF LA"QUINTA, SUB -CONTRACTOR LIST c�� sr.�..cn•`
JOB ADDRESS �1 MIANN AME PERMIT NUMBER' OWNER 4f v i SHS Q "t- BUILDER C_PfLtc&VT
This form shall be costed on the job with the Building Inspection Card'at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized. to work
on this job. Any changes to this list must be approved by the Building .Division prior to .commencement of work. Failure to comply will result in a stoppage of work and/or the voidance
of building permit. For each applicable trade, all information requested below must be completed by applicant. "On File" is not an acceptable response.
ion
Trgde.:..;.Class,tic�............:
G
................_.......5���ot...:.::::::.:.:.::;.:::>..:::;
:.>:,..:;;.;>;:::................�o�..........i.................
1�0.� ..............n _nd.......::::..::..: ..;....;..;......
. ,:::...
Company Name
Classification
(e.g. A, B, C-8)
License Number
(xxxxxx)
Exp: Date
(xx/xx/xx)
Carrier Name
(e.g. State Fund, CalComp)
Policy Number
(Format Varies)
Exp. Date
(xx/xx/xx)
License Number
(xxxx)
Exp. Date
(xx/xx/xx)
;EA .TH:W:ORK (G- 21
coNc rE.cc-sl!:..
I -e -f 4_zq
too yo Z.
a"k~ Atey ths, r",p
of toZb
STRUGT.:STE�1 (C
f .
MASOkRY (C=29).
PLUMBIOG. (.C.-3.0
a ;.PI_asT�Rtc- �
rA
C-3Slp/
f(,p€`i_9",'
j� 13
2CG✓
w0DY000fs70Z.
DRYWALL (C=9).. ....
t.
H,V (C 2a) 1
laic s da�2 �H�� oy��
C-20
75/ S'�
1t 11,114
S1 -4r2 ya.S tom:
INK1`4�irl�i� rp t .
;-�,.,
9 b4lm
3o 3S.
It13�f ►2
c:.
Tf�cat (c=tv)
�%Zw ��.. £e 4 e��2ee
t?'- l v
7 0
q 3
3► i z
Srae.. eo k s� L �(
N
/f 9'3
3// -
l 0.51 Z (o
�l la
R uu (cos):.:.
AL aricct't e'sJ44 ffe&F",,5
t - 3°I
3WY7
? / t3
57'491-t r -t, KCf
600 q?Zo- ZO
z
/6(
SPr
>SHEEr:METAL (G4.31
.GLAzING. (04
INsu ►Ttow:::Ec-2} ::
442u1 Z0144 z
C- 2
qvm S Z ?
'%1"113
eato e-.,.
oil
t1w I 12
I o ryd
till t3
SEWAGE-DISP. (C.=42):.
PAINTING: (C-33)
33
y ,
ffS /S �-
Z/ZY
SEc�
TNcr rvp�• �+ict c°tt.�.
CERAMI..0 T[LE (C-54)
i
CABINETS
FENCING
LAND;KAPMG IC -27Y
POOL (C=53)
(/
Bin # tek
City of La Quinta
Building & Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
'
Project Address:r.__.06; /� , ^p�n
.Owner's Name: Mr. Kenneth Plam
A. P. Number: 777-310-019
Address: 80-125 Miramonte Lane
Legal Description: Lot No. 19 Sec. 4 T:6 S. R.7 E.
Kenneth Plam
Contractor: Mr. Ke
City, ST, Zip: La Quinta; CA 92253-9059
- -4
Telephone: 1 hone• 1 760 972 4 65
P
Address: 80-125 Miramonte Lane
Project Descr iption:
City, ST, Zip: La Quinta, CA 92253-9059
An Addition To An Existing Single Family Residence
Telephone:7 -4465.
1- 760 9 2
State Lic. # :
City Lic. #;
Arch., Engr., Designer: Mike Mendoza-Designer
Address: P.O. Box 692
City., ST, Zip: Desert Hot Springs, CA 92240
- 27 -1816
Telephone: 1 760 5
P (
...................................................
n VB
Co tructi n Type:
s o Occu anc R1
YP Y�
P
State Li N/A
Project tYPa(circle one):: New (9n) Alter Repair Demo
Name of Contact Person: Mike Mendoza-Designer
Sq. Ft.: 498.0
#Stories: 01
#Units:
Telephone # of Contact Person: 1-(760 275-1816
Estimated Value of Project: Z/0 DOD
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING
PERMIT FEES
Plan Sets
3
Plan Check submitted, ` /�
Item
Amount
Structural Calcs.
2,
Reviewed, ready for corrections d,
Plan Check Deposit
Truss Calcs.
a-
Called Contact Perso g
Plan Check Balance.
Title 24 Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted % r' 0
Mechanical
Grading plan
2"" Review, ready fo corrections/ ssue
Electrical
Subcontactor List
Called Contact Person f
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
r
Plans resubmitted
Grading
IN HOUSE:-
'^' Review, ready for correction
Developer Impact Fee
Planning Approval
Called Contact Person ��
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
%/l8 STS
?/30 /0'// .. ST2.A' 9 l2
9/.27 -� �ito� dAA-.-- /V • // - //
Ava4 tRL.6 ---V race Q -Lo css cd6 +�sT
Coachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
• This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT - -
LEVELONEAMOUNT:
LEVELTWOAMOUNT:
MITIGATION AMOUNT:
COMMAND. AMOUNT:
DATE:
RECEIPT:
CHECK#:
INITIALS:
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: Kenneth & Shirley Plam (Mountain_View CC) Date: January 12, 2012
Owner's Name: Kenneth &Shirley Plam Phone No. 760-601-5588
Project Address: 80-125 Miramonte Ln., LaQuinta, CA
Project Description: Family Room Addition to Existing SFD "
APN: 777-310-019 Tract #:
Type of Development: Residential
Commercial Industrial
Total Square Feet of Building Area: 428 sq. ft.
Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under
penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer.
Dated: January 12, 2012 Signature:
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
i
Education Code Gov. Code Project
17620 65995 Approval
Note:
Number of Sq.Ft. 428 sq., ft.
Amount per Sq.Ft. $ 0.00
Amount Collected $ 0.00
Building Permit Application Completed: Yes/No
By: Jamie T. Brown, Asst. Supt., Business Services
Agreement Existing
Prior to 1/1/87
Not Subject to. Fee
Requirement
Certificate issued by: Laurie Howard, Secretary IH Signature:
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that'the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior. to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted.
MV:c/mydocs/dcvfees, cellilicateofcompliance form tablesfO USE.doc 1/16/03 T ,
Monarch Management Group
A DIVISION OF THE MANAGEMENT TRUST
MOUNTAIN VIEW
COUNTRY CLUB
at La Quinta
October 19, 2011
Mr. Ken Plam
80-125 Miramonte Lane
La Quinta, CA 92253
Re: Architectural Request
Miramonte Lane
Dear Mr. Plam:
The Architectural/Landscape Committee of the Mountain View Country Club
Homeowners' Association have reviewed the plans to install a casita to your
home per the application submitted. The committee is pleased to inform you that
it has approved the application. Please note the following:
• The addition of 498 sq. feet to your great room and 96 sq. feet to the
storage room.
Thank -you for your patience and understanding during this approval process. If
there -are any questions please contact me at 760-776-5100 ext. 333.
Sincerely,
FOR THE BOARD OF DIRECTORS
MOUNTAIN VIEW COUNTRY CLUB
Heather Yslas
Association Assistant Manager
cc: Board of Directors
Unit File
39755 Berkey Drive, Suite A, Palm Desert, CA 92211
CONNECTING PEOPLETOTHEPROMISE PH: 760.776.5100 FAX: 760:776.5111
www.managementtrust.com
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Mr. Kenneth & Mrs. Shirley Plarn
80125 Miramonte Lane @ Mountain View C.C.
La,Quinta, Ca 92253. ,
Project Designer:
Mike Mendoza
P. O. BOX 692
Desert Hot Springs, Ca 92240
1-(760) 275-1816
Report Prepared by: - f
Santiago Lopez-Ocampo
Santiago Lopez-Ocampo
P.O. Box 1018
La Quinta, Ca 92247
760.485.8927
11-gms-
CITY.OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
w
_ Job Number: DATE 1 11 B ARL
[) Ig052911-corr082911
AUG 3 0 2011
Date:'
By 8/29/2011
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
Ener Pro 5.1 by Energ Soft User Number: 5732 RunCode: 2011-08-29T19:26:53 ID: 1q05291 1 -corr08291 I
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Summary 12
HVAC System Heating and Cooling Loads Summary. 15
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Mr. Kenneth & Mrs. Shirley Plam
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
8/29/2011
Project Address
80125 Miramonte Lane @ Mountain View
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,403
Addition
428
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes El No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity (ft) Features see Part 2 of 5 Status
Slab Unheated Slab -on -Grade None 2,975 Perim = 247' Existing
Wall Wood Framed R-19 2,972 Existing
Roof Wood Framed Attic R-38 3,011 Radiant Barrier Existing
Door Opaque Door None 49 Existing
Slab Unheated Slab -on -Grade None 428 Perim = 41' New
Wall Wood Framed R-21 786 New
Roof Wood Framed Attic R-38 392 Radiant Barrier New
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
Right (SIM 96.0 0.550
0.67 none none Bug Screen Existing
Rear (S) 39.0 0.550
0.67 none none Bug Screen Existing
Rear (SE) 276.5 0.550
0.67 none none Bug Screen Existing
Front (NW) 16.0 0.550
0.67 none none Bug Screen Existing
Front (NW) 14.0 0.510
0.66 none none Bug Screen Existing
Right (W) 34.5 0.550
0.67 none none Bug Screen Existing
Right (SIM 5.4 0.510
0.66 none none Bug Screen Existing
Right (SIM 67.5 0.550
0.67 none none Bug Screen Removed
Rear (SE) 47.5 0.550
0.67 none none Bug Screen Removed
Left (NE) 43.3 0.510
0.66 none none Bug Screen Existing
Right (SIM 5.4 0.510
0.66 none none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace 78% AFUE
Split Air Conditioner 12.0 SEER Setback
Existing
1 Central Furnace 78% AFUE
Split Air Conditioner 12.0 SEER Setback
Existing
1 Central Furnace 78% AFUE
Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC System - Zone 1 Ducted
Ducted Attic, Ceiling Ins, vented 6.0
Existing
HVAC System - Zone 2 Ducted
Ducted Attic, Ceiling Ins, vented 6.0
Existing
HVAC System - Zone 3 Ducted
Ducted Attic, Ceiling Ins, vented 6.0
Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
Ener Pro 5.1 by Ener Soft User Number: 5732
Run Code: 2011-08-29719:26:53 ID: 1 052911-corr082911
Page 3 of 17
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Mr. Kenneth & Mrs. Shirley Plam
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
8/29/2011
Project Address
80125 Miramonte Lane @ Mountain View
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,4G
Addition
428
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes I I No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity (ft) Features see Part 2 of 5 Status
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
Rear (S) 22.5 0.390 0.37 none none Bug Screen New
Rear (SE) 22.5 0.390 0.37 none none Bug Screen New
Left (E) 22.5 0.390 0.37 none none Bug Screen New
Left (E) 15.0 0.550 0.67 none none Bug Screen Existing
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
Energ Pro 5.1 by Energ Soft User Number: 5732 Run Code: 2011-08-29719:26:53 ID: 1 052911-corr082911
Page 4 of 17
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
Mr. Kenneth & Mrs. Shirley Plam
Building Type ® Single Family ❑ Addition Alone
1 ❑ Multi Family ® Existing+ Addition/Alteration
Date
8/29/2611
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The Existing Furnace Default FAU/AC 2006 and Later has an AFUE less than the Vintage Defaults. Field verification is required.
HIGH MASS Design - Verify Thermal Mass: 117.0 ft' Exposed Slab Floor, 4.000" thick at Zone 1
HIGH MASS Design - Verify Thermal Mass: 262.0 ft2 Covered Slab Floor, 4.000" thick at Zone 1
The Existing Furnace Default FAU/AC 2006 and Later has an AFUE less than the Vintage Defaults. Field verification is required.
HIGH MASS Design - Verify Thermal Mass: 1,349.0 ft2 Exposed Slab Floor, 4.000" thick at Zone 2
HIGH MASS Design - Verify Thermal Mass: 428.0 ft' Exposed Slab Floor, 4.000" thick at Zone 2 - Addition
The Existing Furnace Default FAU/AC 2006 and Later has an AFUE less than the Vintage Defaults. Field verification is required.
HIGH MASS Design - Verify Thermal Mass: 479.0 112 Exposed Slab Floor, 4.000" thick at Zone 3
HIGH MASS Design - Verify Thermal Mass: 768.0 ft2Covered Slab Floor, 4.000" thick at Zone 3
The Roof R-38 Roof Attic w/Radiant Barrier includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as
specified in Residential Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
EnergyPro 5.1 by Ener Sok User Number. 5732 Run Code: 2011-08-29719:26:53 ID: 1q05291 1 -corro8291 I Pa e 5 of 17
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Mr. Kenneth & Mrs. Shirley Plam
❑ Multi Family m Existing+ Addition/Alteration
1812912011
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 5.16 2.92 2.24
Space Cooling 113.21 105.52 7.69
Fans 24.98 23.14 1.84
Domestic Hot Water 9.44 9.44 0.00
Pumps 0.00 0.00 0.00
Totals 152.79 141.02 11.76
Percent Better Than Standard: 7.7
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
'
Building Front Orientation: (NiM 315 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (NK) 579 30
Fuel Available at Site: Natural Gas (NE) 1,450 81
Raised Floor Area: 0 (SE) 1,059 361
Slab on Grade Area: 3,403 (SIM 1,332 141
Average Ceiling Height: 11.4 Roof 3,403 0
Fenestration Average U -Factor: 0.53 TOTAL: 613
Average SHGC: 0.64 Fenestration/CFA Ratio: 18.0%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Santiago Lopez-Ocampo �
8/29/2011
Address P.O. Box 1018 Name Santiago Lopez-Ocampo
.City/State/Zip.City/State/Zip La Quinta, Ca 92247 Phone 760.485.8927 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing.require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Mike Mendoza
Address P. O. BOX 692 Name
City/State/Zip Desert Hot Springs, Ca 92240 Phone 1-(760) 275-1816 Signed Ucense # Date
Ener Pro 5.1 b Ener Soft User Number: 5732 RunCode: 2011-08-29T19:26:53 ID:105291 1-con,082911 Pa e 6 of 17
. - A�V♦ r.. .-0 f'r. •fes ,i -,.t S • ' ,� y , , , ` 1 �-" -��� t • ,'
'CERTIFICATE OF COMPLIANCE:
Residential
Part 4 of 5) CF -1 R
Project Name
Mr. Kenneth & Mrs. Shirley Plam
Building Type m Single Family ❑ Addition Alone
O Multi Family m Existing+ Addition/Alteration
Date
1812912011
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments
Slab
117
0.730 None
0
180 Existing 4.4.7-A1
Zone 1
Slab
262
0.730 None
0
180 Existing 4.4.7-A1
Zone 1
Wall
170
0.074 R-19
225
90 Existing 4.3.1-A5
Zone 1
Wall
36
0.074 R-19
180
90 Existing 4.3.1-A5
Zone 1
Wall
161
0.074.R-19
135
90 Existing 4.3.1-A5
Zone 1
Wall
23
0.074 R-19
45
90 Existing 4.3.1-A5
Zone 1
Wall
163
0.074 R-19
315
90 Existing 4.3.1-A5
Zone 1
Roof
379
0.025 R-38
0
0 Existing 4.2.1-A21
Zone 1
Slab
1,349
0.730 None
0
180 Existing 4.4.7-A1
Zone 2
Wall
93
0.074 R-19
270
90 Existing 4.3.1-A5
Zone 2
Door
28
0.500 None
270
90 Existing 4.5.1-A4
Zone 2 .
Wall
541
0.074 R-19
225
90 Existing 4.3.1-A5
Zone 2
Wall
216
0.074 R-19
135
90 Existing 4.3.1-A5
Zone 2
Wall
238
0.074 R-19
45
90 Existing4.3.1-A5
Zone 2
Wall
185
0.074 R-19
315
90 Existing 4.3.1-A5
Zone 2
Door
21
0.500 None
315
90 Existing 4.5.1-A4
lZone 2
FENESTRATION SURFACE DETAILS
ID
Type
Area LI -Factor'
SHGC
Azm Status
Glazing Type
Location/Comments
1
Window
6.0 0.550 Default
0.67 1 Default
225 Existing
Double Non Metal Clear
Zone 1
2
Window
24.0 0.550 Default
0.67 Default
225 Existing
Double Non Metal Clear
Zone 1
3
Window
24.0 0.550 Default
0.67 Default
180 Existing
Double Non Metal Clear
Zone 1
4
Window
15.0 0:550 Default
0.67 Default
135 Existing
Double Non Metal Clear
Zone 1
5
Window
24.0 0.550 Default
0.67 Default
135 Existing
Double Non Metal Clear
Zone 1
6
Window
8.0 0.550 Default
0.67 Default
315 Existing
Double Non Metal Clear
Zone 1
7
Window
14.0 0.510 NFRC
0.66 NFRC
315 Existing
Pittsburgh Corning GB
Zone 1
8
Window
6.0 0.550 Default
0.67 Default
270 Existing
Double Non Metal Clear
Zone 2
9
Window
24.0 0.550 Default
0.67 Default
270 Existing
Double Non Metal Clear
Zone 2
10
Window
4.5 0.550 Default
0.67 Default
270 Existing
Double Non Metal Clear
Zone 2
11
Window
6.0 0.550 Default
0.67 Default
225 Existing
Double Non Metal Clear
Zone 2
12
Window
24.0 0.550 Default
0.67 Default
225 Existing
Double Non Metal Clear
Zone 2
13
Window
2.7 0.510 NFRC
0.66 NFRC
225 Existing
Pittsburgh Coming GB
Zone 2 .
14
Window
2.7 0.510 NFRC
0.66 NFRC
225 Existing
Pittsburgh Corning GB
Zone 2
15
Window .
4.5 0.550 Default
0.67 Default
225 Removed Double Non Metal Clear
Zone 2
16
Window
18.0 0.550 Default
0.67 Default
225 Removed Double Non Metal Clear
Zone 2
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type:. 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
Hot Wd
Ove hanq Left Fin
Len H t LExt RExt Dist Len
Ri ht Fin
H t Dist Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
-
-
13
Bug Screen
0.76
14
Bug Screen
0.76
j
15
Bug Screen
0.76
16
JBug Screen
0.76
Ener Pro 5.1 by Ener Soft User Number. 5732 RunCode: 2011-08-29719:26:53 ID: 1 052911-corr082911 Page 7 of 17
`
Project Name
Mr. Kenneth & Mrs. Shirley Plam
r
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
8/29/2011
OPAQUE SURFACE DETAILS
i
Surface
Type Area
Ll- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof
1,349
0.025 R-38
0 0 Existing 4.2.1-A21
Zone 2
Slab
428
.0.730 None
0 180 New 4.4.7 -Al
Zone 2 - Addition
Wall
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R
Project Name
Mr. Kenneth & Mrs. Shirley Plam
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
8/29/2011
OPAQUE SURFACE DETAILS
Surface
Type Area
Ll- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof
1,349
0.025 R-38
0 0 Existing 4.2.1-A21
Zone 2
Slab
428
.0.730 None
0 180 New 4.4.7 -Al
Zone 2 - Addition
Wall
291
0.069 R-21
225 90 New 4.3.1-A6
Zone 2 - Addition
Wall
29
0.069 R-21
180 90 New 4.3.1-A6
Zone 2 - Addition
Wall
119
0.069 R-21
135 90 New 4.3.1-A6
Zone 2 - Addition
Wall
29
0.069 R-21
90 90 New 4.3.1-A6
Zone 2 - Addition
Wall
138
0.069 R-21
45 90 New 4.3.1-A6
Zone 2 - Addition
Wall
180
0.069 R-21
315 90 New 4.3.1-A6
Zone 2 - Addition
Roof
392
0.025 R-38
0 0 New .4.2. 1-A21
Zone 2 - Addition
Roof
36
0.025 R-38
0 0 Existing 4.2.1-A21
Zone 2 - Addition
Slab
479
0.730 None
0 180 Existing 4.4.7-A1
Zone 3
Slab
768
0.730 None
0.- 180 Existing 4.4.7-A1
Zone 3
Wall
69
.0.074 R-19
225 90 Existing 4.3.1-A5
Zone 3
Wall
16
.0.074 R-19
180 90 Existing 4.3.1-A5
Zone 3
Wall
121
0.074 R-19
135 90 Existing 4.3.1-A5
Zone 3
Wall
16
0.074 R-19
90 90 Existing 4.3.1-A5
lZone 3
FENESTRATION SURFACE DETAILS
ID
Type
Area LI -Factor'
SHGC Azm. Status Glazing Type
Location/Comments
17
Window
4.5 0.550 Default
0.67 Default 225 Removed Double Non Metal Clear
Zone 2
18
Window
18.0 0.550 Default
0.67 Default 225 Removed Double Non Metal Clear
Zone 2
19
Window
4.5 0.550 Default
0.67 Default 225 Removed Double Non Metal Clear
Zone 2
20
Window
18.0 0.550 Default
0.67 Default 225 Removed Double Non Metal Clear
Zone 2
21
Window
7.5 0.550 Default
0.67 Default 135 Removed Double Non Metal Clear
Zone 2 '
22
Window
40.0 0.550 Default
0.67 Default 135 Removed Double Non Metal Clear
Zone 2
23
Window
13.5 0.550 Default
0.67 Default 135 Existing Double Non Metal Clear
Zone 2
24
Window
72.0 0.550 Default
0.67 Default 135 Existing Double Non Metal Clear
Zone 2
25
Window
9.0 0.550 Default
0.67 Default 135 Existing Double Non Metal Clear
Zone 2
26
Window
48.0 0.550 Default
0.67 Default 135 Existing Double Non Metal Clear
Zone 2
27
Window
8.0 0.510 NFRC
0.66 NFRC 45 Existing Pittsburgh Coming GB
Zone 2
28
Window
7.8 0.510 NFRC
0.66 NFRC 45 Existing Pittsburgh Coming GB
Zone 2 _
29
Window
8.0 0.550 Default
0.67 Default 315 Existing Double Non Metal Clear
Zone 2
30
Window
1.8 0.510 NFRC
0.66 NFRC 225 New Pittsburgh Coming GB
Zone 2 - Addition
31
Window
1.8 0.510 NFRC
0.66 NFRC 225 New Pittsburgh Corning GB
Zone 2 - Addition
32
Window
1.8 0.510 NFRC
0.66 NFRC 225 New Pittsburgh Corning GB
Zone 2 - Addition
(1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value -
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window Ove hanq Left Fin Ri ht Fin
H t I Wd Len H t LExt RExt Dist Len H t Dist Len H t
17
Bug Screen
0.76
18,
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen ,
0.76
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76
30
Bug Screen
0.76
31
IBug Screen
0.76
F=F
32
Bug Screen
0.76
Ener Pro 5.1 by Ener Soft User Number: 5732 Run Code: 2011-08-29719:26:53 ID: 1 052911-corr082911. Page 8 of 17
r
CERTIFICATE OF COMPLIANCE:
Residential
Part 4 of 5 CF-1 R
Project Name
Mr. Kenneth & Mrs. Shirley Plam
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
8129/2011
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments
Wall
715
0.074 R-19
45
90 Existing 4.3.1-A5
Zone 3
Wall
209
0.074 R-19
45
90 Existing 4.3.1-A5
Zone 3
Roof
1,247
0.025 R-38
0
0 Existing 4.2.1-A21
Zone 3
FENESTRATION SURFACE DETAILS
ID
Type
Area U-Factor
SHGC
Azm Status
Glazing Type
Location/Comments
33
Window
4.5 0.390 NFRC
0.37 NFRC
180 New
Milgard Classic Low-E Vinyl
Zone 2 - Addition
34
Window
18.0 0.390 NFRC
0.37 NFRC
180 New
Milgard Classic Low-E Vinyl
Zone 2 - Addition
35
Window
4.5 0.390 NFRC
0.37 NFRC
135 New
Milgard Classic Low-E Vinyl
Zone 2 - Addition
36
Window
18.0 0.390 NFRC
0.37 NFRC
135 New
Milgard Classic Low-E Vinyl
Zone 2 - Addition
37
Window
7.5 0.550 Default
0.67 Default
135 Existing
Double Non Metal Clear
Zone 2 - Addition
38
Window
40.0 0.550 Default
0.67 Default
135 Existing
Double Non Metal Clear
Zone 2 - Addition
39
Window
4.5 0.390 NFRC
0.37 NFRC
90 New
Milgard Classic Low-E Vinyl
Zone 2 - Addition
40
Window
18.0 0.390 NFRC
0.37 NFRC
90 New
Milgard Classic Low-E Vinyl
Zone 2 - Addition
41
Window
6.0 0.550 Default
0.67 Default
225 Existing
Double Non Metal Clear
Zone 3
42
Window
24.0 0.550 Default
0.67 Default
225 Existing
Double Non Metal Clear
Zone 3
43
Window
6.0 0.550 Default
0.67 Default
225 Existing
Double Non Metal Clear
Zone 3
44
Window
3.0 0.550 Default
0.67 Default
180 Existing
Double Non Metal Clear
Zone 3
45
Window
12.0 0.550 Default
0.67 Default
180 Existing
Double Non Metal Clear
Zone 3
46
Window
7.5 0.550 Default
0.67 Default
135 Existing
Double Non Metal Clear
Zone 3
47
Window
40.0 0.550 Default
0.67 Default
135 Existing
Double Non Metal Clear
Zone 3
48
Window
3.0 0.550 Default
0.67 Default
90 Existing
Double Non Metal Clear
Zone 3
(1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
Hat FWd
Ove hanq Left Fin
Len Hat LExt I RExt Dist Len
Ri ht Fin
Hat Dist Len H t
33
Bug Screen
0.76
34
Bug Screen
0.76
35
Bug Screen
0.76
36
Bug Screen
0.76
37
Bug Screen
0.76
38
Bug Screen
0.76
39
Bug Screen
0.76
40
Bug Screen
0.76
41
Bug Screen
0.76
42
Bug Screen
0.76
43
Bug Screen
0.76
44
Bug Screen
0.76
45
Bug Screen
0.76
46
Bug Screen
0.76
47
JBug Screen
0.76
48
18ug Screen
0.76
EnergyPro
5.1 by Ener Soft User Number: 5732 RunCode: 2011-08-29719:26:53 ID: 1 052911-corr082911 Page 9 of 17
CERTIFICATE OF COMPLIANCE:
Residential (Part 4 of 5) CF -1 R
Project Name
Mr. Kenneth & Mrs. Shirley Plam
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
812912011
OPAQUE SURFACE DETAILS
Surface U-
Type Area Factor
Insulation Joint Appendix
Cavity Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID Ty.pe Area
U -Factor SHGC
Azm Status Glazing Type Location/Comments
49 Window 12.0
0.550 Default 0.67 Default
90 Existing Double Non Metal Clear Zone 3
50 Window 1.8
0.510 NFRC 0.66 NFRC
45 Existing Pittsburgh Coming GB Zone 3
51 Window 1.8
0.510 NFRC 0.66 NFRC
45 Existing Pittsburgh Coming GB Zone 3
52 Window 5.3
0.510 NFRC 0.66 NFRC
45 Existing Pittsburgh Corning GB Zone 3
53 Window 5.3
0.510 NFRC 0.66 NFRC
45 Existing Pittsburgh Corning GB Zone 3
54 Window 5.3
0.510 NFRC 0.66 NFRC
45 Existing Pittsburgh Corning GB Zone 3
55 Window 8.0
0.510 NFRC 0.66 NFRC
45 Existing Pittsburgh Corning GB Zone 3
(1) U -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID Exterior Shade Type
Window
SHGC Hat Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len H t Dist Len H t
49 Bug Screen
0.76
50 Bug Screen
0.76
51 Bug Screen
0.76
52 Bug Screen
0.76
53 Bug Screen
0.76
54 Bug Screen
0.76
55 Bug Screen
0.76
Ener Pro 5.1 by Ener Soft
User Number: 5732 Run Code: 2011-08-29T19:26:53 ID: 1 052911-corr082911 Pae 10 of 17
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R
Project Name
Mr. Kenneth & Mrs. Shirley Plam
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
8/29/2011
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area ft
New Existing Altered Removed Volume Year Built
HVAC System - Zone 1 Zone 1
379
3,790 2006
HVAC System - Zone 2 Zone 2
1,349
16,188 2006
Zone 2 - Addition
428
5,136
HVAC System - Zone 3 Zone 3
1,247
13,717 2006
Totals 4281 2,9751 01 0
HVAC SYSTEMS
System Name Qty. Heating Ty e
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
HVAC System - Zone 1 1 Central Furnace
78% AFUE Split Air Conditioner 12.0 SEER Setback
Existing
HVAC System - Zone 2 1 Central Furnace
78% AFUE Split Air Conditioner 12.0 SEER Setback
Existing
HVAC System - Zone 3 1 Central Furnace
78% AFUE Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
System Name Heating
Duct
Cooling Duct Location R-Value
Ducts
Tested? Status
HVAC System - Zone 1 Ducted Ducted Attic, Ceiling Ins, vented 6.0
❑ Existing
HVAC System - Zone 2 Ducted Ducted Attic, Ceiling Ins, vented 6.0
❑ Existing
HVAC System - Zone 3 Ducted Ducted Attic, Ceiling Ins, vented 6.0
❑ Existing
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Rheem 41VRP50PT
1
Small Gas
Kitchen Pipe Ins
40,000
50
0.65
n/a
n/a
Existing
MULTI-FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
ft
o
c
Q —
System Name
Pipe
Len th
Pipe
Diameter
Insul.
Thick.
7aty.HP
Plenum Outside Buried
EnergyPro 5.1 by Ener Soft User Number 5732
RunCode: 2011-08-29719:26:53 ID: 1q05291 1-cof-f082911 Pa a 11 of 17
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Mr. Kenneth & Mrs. Shirley Plam
Date
8/29/2011
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
§150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculatin sections*of hot water pipes are insulated per Standards Table 150-13.
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
§150(i)3A: Insulation.is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
§150(i)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoft User Number: 5732 Run Code: 2011-08-29T19:26:53 ID: Ig052911-corr08291 Page 12o117
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Mr. Kenneth & Mrs. Shirley Plam
8/29/2011
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tae is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool.systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 tt2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoft User Number. 5732 RunCode: 2011-08-29719:26:53 ID: lg052911-corr08291 Page 13 of 17
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Mr. Kenneth & Mrs. Shirley Plam
1812912011
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)s2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall'comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoft User Number. 5732 RunCode: 2011-08-29719:26:53 ID: lg052911-corr08291 Page 14 of 17
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Mr. Kenneth & Mrs. Shirley Plam
Date
8/29/2011
System Name
HVAC System - Zone 1
Floor Area
379
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 442
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation F 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 0
8,474
576 193
7,203
Total Output Btuh o
0
Output Btuh/s ft 0.0
578
415
Cooling System
0
0
Output per System 1
0
0 0
0
Total Output Btuh 1
0
576
0
Total Output Tons 0.0
578
415
Total Output Btuh/s ft 0.0
Total Output s ft/Ton 4,548,000.0
1 9,630
8,034
Air System
CFM per System
0
HVAC EQUIPMENT SELECTION
Airflow cfm
0
Default FAU/AC 2006 and Later
1
0
0
Airflow cfm/s ft
0.00
Airflow cfm/Ton
0.0
Outside Air Bio
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
1
0 0
Aug 3 PM Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCH ROM ETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF
Outside Air
0 cfm
66°F
66 OF 105 OF
Heating Coil
4 FEE
103 OF
:....... ........... _._.......... __._....
ROOM
68 OF
COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air Ar
0 cfm
77 / 63 OF
77/63°F 55/54°F
Cooling Coil
-
Fr
57 / 55 OF
49.5% ROOM
75 / 62 OF
EnergyPro 5.1 by EnergySoft
User Number: 5732 Run Code: 2011-08-29719:26:53
ID: lg052911-corr082911 Page 15 of 17
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Mr. Kenneth & Mrs. Shirley Plam
Date
8/29/2011
System Name
HVAC System - Zone 2
Floor Area
1,777
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,784
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation o
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 0
34,168
2,962 715
26,888
Total Output Btuh 0
0
Output Btuh/s ft 0.0
2,332
1,551
Cooling System
0
0
Output per System 1
0
0 0
0
Total Output Btun 1
01
2,962
0
Total Output (Tons) 0.0
2,332
1,551
Total Output (Btuh/s ft) 0.0
Total Output s ft/Ton 21,324,000.0
38,831
29,989
Air System
CFM perSystem
0
HVAC EQUIPMENT SELECTION
Airflow cfm
0
Default FAU/AC 2006 and Later 1
0
0
Airflow cfm/s ft
0.00
Airflow cfm/Ton
0.0
Outside Air %
0.0%
Total Adjusted System Output 1
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
0 ` o
Aug 3 PM Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
66 OF
66 OF 105 OF
Heating Coil
i --EE 4
103 OF
.---................----.......__
ROOM
68 OF
COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air
0 cfm
77 163 OF
77/63°F 55/54°F
e
Cooling Coil 57 / 55 OF
49.9% I' ..ROOM
t
_ 75162 OF
EnergyPro 5.1 by EnergySoft
User Number: 5732 RunCode: 2011-08-29719:26:53 ID: Ig052911-corrO82911 Page 16 of 17
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Mr. Kenneth & Mrs. Shirley Plam
Date
8/29/2011
System Name
HVAC System - Zone 3
Floor Area
1,247
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,174
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation o
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 0
22,485
1,636 348
13,261
Total Output (Btuh) 0
0
Output Btuh/s ft 0.0
1,534
765
Cooling System
0
0
Output perSystem 1
0
0 0
0
Total Output Btuh 1
0
1,534
25,554
1,636
0
Total Output (Tons) 0.0
765
Total Output (Btuh/s ft) 0.0
Total Output s ft/Ton 14,964,000.0
14,790
Air System
CFM perSystem
0
HVAC EQUIPMENT SELECTION
Airflow cfm
0
Default FAU/AC 2006 and Later 1
0
0
Airflow cfm/s ft
0.00
Total Adjusted System Output 1
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
0 0
Aug 3 PM I Jan 1 AM
Airflow cfmrron 0.0
Outside Air % 0.0 %
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
67 OF
67 IF 105 OF
Heating Coil
_
A =
104 OF
__.._......... _..... __...
ROOM
68 OF
COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air Ar
0 cfm
77/63°F
77/63°F 55/54°F
Cooling Coil 57 155 OF
49.0% ROOM
i.
75/62°F
EnergyPro 5.1 by EnergySoff
User Number: 5732 RunCode: 2011-08-29T19:26:53 /D: lg052911-corrO82911 Page 17 of 17
r
STRUCTURAL CALCULATIONS
A RESIDENCE ADDITION
FOR:
MR. & MRS,-- PLAM
80125 MIRAMONTE LANE
LA QUINTA , CALIFORNIA
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
..APPROVED��Ep ARS
FOR CONSTRUCTION b�
CHARLES D. GARLAND, ARCH ITE T cc� QQ��S' Gg9ly
LICENSE Na 119.91 EXP 10/31 1[)ATE B s 2
74-991 JONI DR. SUITE #9 PALM DESERT CA 92260 * " No. C11991
10/31/2011 Q
PHONE: 760/340-3528 FAX:760/340-3728 TE
9 Q�
F�
C A \
-SEP 2 7 2011 1
BY. 3
-
STRUCTURAL CALCULATIONS t
❖ GOVERNING CODES.....................page 3
❖ LOAD ...................................... .................... Page 4
BEAM.................................................. Page 5
COLUMN................................................ Page 6
❖ LATERAL ANALYSIS.. ............... Page 10
❖ SEISMIC ZONE ............................ Page 12
❖ SHEAR WALL REQUIREMENTS.... Page 13
❖ FOUNDATION ................ ......... ...... Page 14
STRUCTURAL CALCULATIONS'
GOVERNING CODES
A- IBC 2009 OR CBC 2010 & ORDINANCE 457 OF RIVERSIDE
COUNTY
B- DESIGN LOADS
a.. ROOF LIVE LOAD 20, PSF
b. ROOF DEAD LOAD 19 PSF
c. WIND IMPORTANCE FACTOR 1.00 WIND ZONE 95•MPH
EXPOSURE C
d. SITE CLASS DEFINITION (D)
e. OCCUPANCY CATEGORY II
f. SEISMIC DESIGN CATEGORY (D)
g. COEFFICIENT Cs 0.15
h. SEISMIC Ss1.5g
i. SEISMIC Sl 0.6g
j. FACTOR R 6.5
k. SEISMIC SDs 1.00
I. SEISMIC SD10.60
STRUCTURAL CALCULATIONS
`
LOADS
z ,
►
ROOF
EXTERIOR WALLS
PSF
;PSF
—._
"WOOD STUDS — 2 '<
T1LE — 9
!1/2 GYP BD
t
SHEATHING — +�; 1
X7/8" STUCCO = 10 +
RAFTERS — 2
JNSULATION= 1
,INSULATION
:G—BD. _� 6
YP. —^D L. 15 'PSF
D. L _ 19
i a
'TOTAL LOAD. 39 Y PSF
INTERIOR WALLS:. '
PSF;
t I
TU
iWOOD SDS 2
1/2GYPBD2SI6 3
tINSULATION 2
PDL 7 SF
STRUCTURAL. CALCULATIONS:
f y
BEAM DESIGN
HDR #1
t
DOUGLAS FIR -LARCH No 1_'... �F-b
..__. -1000. psi . .
SPAN 2.0 'ft1
'
Fv - 95 psi
.
TRIB. AREA °6.0 ft
� i
�.
_....... -I.-
�
E = 1700000 psi
Load Factor
Wet. Service Factor CM = y
1.00'
D. L = 19.0 ; I b/ft
Temperature Factor Ct =
1.00
L.L = 20.0 'Ib/ft
Size Factor CF= -I-1.00
TOTAL 39.0 Ib/ft
;Repetitive m. Fact Cr=
1.00
Incising Factor Ci� = c
1 00:
t iShear
stress Factor CH
1.00
W 234.0
i
1 M=,WxL2/8 ;
234.Ib/ft
+ ;
M 117.01 -lb -'
cvrt-.rr--.:K -yF ,F .r r+�+. -.;ct Y.- •,, -=rFr�-4 _ ..s_ -i :x
... ...«.-. ... ._......_., a'
1404.in lb
_t__€
" 2.00 t i --
_, t >_
''
V W X L/ 2
�
__...,....___.___.•,.f BENDING... ""`..._..�,...+...:._!
V_{.�._.._m234.lb .._�.._..,..�:(
F"b bx(CD)(CM)(Ct)(CF)(Cr)(Ci) I . R -+ •• } -- -__ _. __ w
'12_56.psi
_ y _
F'6
`.Req"d S = M / F"b� _ S=
u 1_ 12 in^3t__
w_USE_ -_'
6_ 6 Area 30.-3'in^_2
Xi
f b =,M/S r Section=, 27.7in^3 _3
ALLOW F"b -
ACT f b = t # i
Moment of Inertia= 76.3,in^4
12504'psi
> 150.6. 1psi
OK
SHEAR
(
1 i
F"v = Fv(CD)(CM)(Ct)(CH)
?f v= ;1.5 V/ A
x
t
Fv = 119 psi
> fv- 11.601psi
OK•
yy n •
DEFLECTION
5WLL^4 ,.- O in
384 E I
OK
E'= E (Cm)(G)(C;) --
1700000 pst _4_
"-
BEAM.
6X!6
max - . ' L / 240 0.10
in i
"
STRUCTURAL CALCULATIONS
BEAM DESIGN`
,
HDR'# 2
DOUGLAS FIR -LARCH No 1=
Tb= 1000 :psi }
SPAN 4.0'ft
Fv = 95 -psi
.TRIB. AREA = .6.0 ft
+ t. '
E = 1700000,psi
Load Factor CD=-
'Wet.
1.25'
Service Factor Cm =
1.00
D.L. = 19.0 Ib/ft
Temperature Factor Ct=
1.00
Ll= ` 20.0 Ib/ft
Size Factor CF= i `.
1.00'
TOTAL: 39.0 ,Ib/ft
�...
Repetitive m Fact Cr-
. _
1.00 ;
Incising Factor Ci = [.....
1.00
..
Shear stress Factor CH-
,.....
1.00' W ' 234.0 'Ib/ft i
r_...._.... v ..,
_ . _.... _
i. .._. ..
WxP 8
234 lb/ft
M=468.0;ft-lb
M=` 5616,in lb
... ., ..-._.. _, «` — ................._—� «. ...;
4.00ftWXL/2'^
_
_ BENDING(
j
V= ..__- 468 Ib
'-F b Fbx(CD)(CM)(Ct)(CF)(Cr)(Ci)
:F"b =1250'psi
-
USE_
Req"d S = M / F"b S=
4.49' in^3 iT
"8 8 Area - 41 .3, in^2
_ _. ._
f b = M/S ?
Section= 51 6: in^3
ALLOW F'b '
ACT f b.=
Moment of Inertia 193 in^4
1250, psi
> 008 9 ;psi I
OK
SHEAR
F v Fv(CD)(CM)(Ct)(CH)
r
v 1.5 V 1 A
t
_- -.
,f
t . ..... .._ .. .........,..
f.... ............ _
F'v =' 119 psi
_ ..... -4. _ 1.. _ .._ {_ . :
> f = 17.02£psi
_......... .._.
10K
_.
_ 1 i
DEFLECTION
i t
}
t
�
5WLL^4 _ O in
«.�,... �
384 E" I �
E'= E (CM)(Q)(CI)
�
OK
_ -1700000 .psi
BEAM
6.xt8
t ,
c1max L/240 = 0.20
in
,
t
STRUCTURAL 'CALCULATIONS
,BEAM DESIGN
t
E
BEAM #1
•
�( !
DOUGLAS FIR -LARCH No 1=� �-Fb 1000 psi
;_ ; Fv-: 95 ~ ipsi
.SPAN 11.0 Ift
TRIB. AREA 'ft 7 i E + 1700000spsi
112.0
1.
Load Factor Co- 1.2
'T
Wet. Service Factor CM = 1.001 _ -
D = L 19 0 Ib/ft
_ _. _
-Temperature Factor Ct = 1.00
_
_.. _L_ .� _
L L = : 20 0 ;Ib/ft �
Size'Factor CF=�- � 1.00` '
TOTAL" 39 0 Ib/ft-7 Repetitive m. Fact. Cr= 1.00,
I
Incising Factor Ci = - 1 00. r
Shear Factor CH= 1.001 ' W 468.0 ilb/ft
stress
M= : W LZ / 8
r 46816/ft
x
M=, 7078.5 f ft -Ib
T.a',tw i. I i. t+'..a=..'w4Y .'.d..v ...:4..(w..-Od ,i- -,_._.."_ ,.tin _ . __. _..
4942 -Ib
ii.00 n
1 BENDING
V=' W x L/ 2
V 25741Ib
F b=#Fbx(CD)(CM)(Ct)(CF)(Cr)(Ci)
^...._
_ . .. ....
__ ........_. «. .. » _�.. ...... - ...„.... ._ _ � Y._-- ,.-..
'......_i.... _., _ _ ..... �.. ...._ __.. ).,, `.,.ate...,._......._.. TY
iF b 1250 psi
USE 1
-Req'd S =jM / F"b S='
67.95: in^3 ;_ 61X,12 Area 63.3: in^2
_ -
_ _
Section= 121 in^3 M
ALLOW F"b -
ACT f b = r Moment of Inertia=l 697 in^4
1250'psi
> 1700.8 psi OK
_ __ __ .--• .SHEAR
Tv= Fv(CD)(CM)(Ct)(CH)
f v 11.5 V/ A 1 :
= 119psi
' `fv-=j 61.04;^psis0K_
_..__F'v
_
DEFLECTION
F . 6WLL^4 f. 0 131in
t
t
384.E" I
_
SOK i
4-
E'= I E (Cm)(G)(C;)
1700000 .psi
BEAM' 6
X 12
I d max = 'L/240 = 0.55'in _.__•.._....
STRUCTURAL CALCULATIONS
BEAM DESIGN:
:
_
BEAM #2
- -
DOUGLAS FIR -LARCH No 1= Fb :
_..
1000 psi
_SPAN = 11.0 ift
'
'
Fv
95 ;psi
_
- .
TRIB. AREA 6 0
E
1700 !psi
Load Factor CD=
1.21
_
w
Wet. Service Factor Cry_
. 1.001
D L = , 19.0 Ib/ft
Temperature Factor Ct=
1.00
L L I Ib/ft
TOTAL' 39.0 �Ib/ft _
Size Factor CF = 4.00,
wRepetitive m. Fact. Cr= 1.00
i:Incising
Factor Ci =
1.00; ,....
Shear stress Factor CH=
1.001
W
234 0
Ib/ft
-_�M=
WxL2/8
! ' 234 j 6/fl
f_
M
-
3539 Ib ,
M
42471 ' in -Ib
11.00 ft
- ��
~ V='W x L / 2
BENDING; +
V
1287;Ib _
F'b = Fbx(CD)(CM)(Ct)(CF)(Cr)(Ci)
�F b , 1250:psi
t
USE
'
-
Req 'd_ S =;M / F'b S=
3.3.98 in_^3
;
6lX:10
Area -
52 3 in^2
-- M
i _
_f b
S_ection=82.7
in^3_-r
SALLOW F'b = t
ACT. f b = ;
Moment of Inertia=
393 in ^4 i
1250;psi
> 513.4 IpsiOK
'SHEAR
' F'v = Fv(CD)(CM)(Ct)(CH)
f v = ;1.5 V / A
_
;F'v = 119`psi
> fv=.'x3695.psi
:OK��
-I
DEFLECTION
5WLL 4._ 0.12 in
,.
I�
` OK
384 E'
E:_fE (CM)(G)(C,)
_s
.1700000 -psi_
- _ _
�L y0.55^in
BEAM
WX 10
r .
d max = /240 -
3
STRUCTURAL CALCULATIONS
LATERAL FORCE ANALYSIS
CBC 2010 ASCE
WIND: 95 mph Exposure C
ENCLOSED Cbz- 0.00256X Kz Kzt Kd V^2 1
Kz= 0.85
#�----
Kzt= 1.00 I
Kd=y 0.85
V 95
..... ..... ._ _... .... _
F f
1= T1.00
qz :.16.69 PSF
H=4 14'
WIND LOAD = qz*(1E+2E+3E+4E+0.18)*H/2 �(
ANALYSIS WIND LOAD 220.34'# ft
Velocity pressure ,
qn = 0.00256 Kn I(Zc Ka V21 - 16.69 - PS_F
Design pressures for MWFRSSLOW- RISE BUILDING (6.5.12.2.2)
p = qh [(G Cpf )-(G Cp; )] (6-18) ' _ P=16.7(1E+2E+3E+ 4E-0.18)
G Cpf :(FIG 6-10) 0.61;---- P=16.7(1E+2E+3E+ 4E+0.18)
G Cpi (FIG -6-5) 0.18; + ,
Net Pressures (osf). Basic Load Cases
Roof angle 0 = 15.64
Roof angle 0 = 0.00
G Cpf
Net Pressure with
G Cpf
Net Pressure with
Surface
(+GCp i)
(-GCp i)
(+GCp i)
(-GCp i
1
0.49
5.21
11.22
0.40
3.67
9.68
2
=0.69
-14.52
-8.51
-0.69
-14.52
-8.51
3
-0.45
10.48
-4.47
-0.37
-9.18
-3.17
4
-0.39
-9.50
-3.49
-0.29
-7.85
-1.84
1 E
0.74
9.43
15.44
0.61
7.18
13.19
2E
-1.07
-20.87
-14.86
-1.07
-20.87
-14.86
3E
-0.64
-13.75
-7.74
-0.53
-11.85
-5.84
4E
-0.58
-12.67
-6.66
-0.43
-10.18
-4.17
5
-0.45
-10.52
-4.51
-0.45
-10.52
-4.51
6
-0.45
1 -10.52
1 -4.51
1 -0.45
1 -10.52
1 -4.51
J.
+ , .f. '. -i •� # tea. i'¢ _if c -r. . 1,�,�
STRUCTURAL "CALCULATIONS
CALIFORNIA B_UIL._D_ING_C_ODE 2_010
MAXIMUM CONSIDERED EARTHQUAKE
~'GROUND MOTION FOR REGION'
E
MCI,
It
ll
-'-.'�xr+' -�"°-sem, ' i�% •� `:, '1 � v '� �' E.P�� e�l� S � .f
}
• I S'
•
H r �
_ a
f
s: _
STRUCTURAL CALCULATIONS
SEISMIC (CONTINUED)
DL
ROOF 19 :Psi
- ;EXT., WALLS 15 Psi _
;SEISMIC, V 0.15 s 'WALL HT= 15:ft
_ TRANSVEf�SEL .-- LONGITUdINAL'„- y -
WORST 24 : FT WORST 44 FT _
ROOF - 456 ROOF — 836
2r WaIIS = 225.'. _ r 2{ Walls =j 225.'. i
681 f. 1061
f
( X, 0.15 X: 0 15 F __
: 102 ;# ft (MA)) y. 159 '# ft (MAX)
i
'SEISMIC=159PLF <220= WIND qff
il ..... _....S .
+
T=C = WL ^2 8bi L= 44 2218.333!
I i 1 B 247_77—
NAIL =STABLE 23-111—C —2 '
TOTAL NAIL = LOAD /NAIL= 11 8
y 4 c
lPR--
OVIDE (8 PAIR)16 d COMMON
__.. _.
@ E_A 4'-0” SPACE @TOP CHORDS -
SHEAR WALL REQUIREMENTS
- SFT � i
. ROOF D.L. = 19. .... WALL HT,1=!12 _ .. .. ... .._ _ .. ...._. ...._.. .. _ -_ APPENDIX D
WALLS D.L. = 15 UPLIFT FORMULA: _ . .. _ ... ....• - ��....._. ,.._.._..... STRENGTH REDUCTION FACT
! (Vh{2/3 (wb L"2/2)+(W�vU2))y L SHEAR = 0.65
0.65.860'1.33'12 /shear force
B 220
6
1320-
_ 2
2
680-
�.1320
' 7783
� SSW24X10 3-
- 24
1,3,6 ,
�. C 220
..7 ... ..
,1._
51W19.5..8
....-
.. ..
_79
. .-
.632_....
531 -
t ..._i .__:....
HDU2 ._._ _ .... ,_ - 1
.. ..48
... .; ..
C ... 220
..1540.
..._.. 19.5.
11.5 —
79
375.__
�. ..-1 .. .a...
HDU2 _. .. _1
r..
`. 46 .....
..1'
..
D 220
6
1320
8
8
165
...
1320 -
1614
_
1
.. .. .
HDU2 1-
48
' 1
E..'_" 220
-. -. ..
.. 4 .......-
..
1"
880
.... _. 12.....'�
_. 12
......_..
73
.,..
__..-.
880 ..
514
_
_. .1
-r .
HDU2. _ . _... 1
...a..,._.
- 1
48
-..
F 220
15
3300
14
14
236
3300
1432'
1
HDU2
WALL HT,1
= 12
UPLIFT FORMULA.
Nh-(2/3 (wb L^2/2)+(WwU2)))/ l
r _
f
TOTAL
RESIST,WAL SHEARFORCE
LOAD(V)
WALL
Vh
V11b
2/3(ML^2/2)
WwU2
UPLIFT.FOROE
WALL (Ft)
(FT) (L)
(# / ft)
WALL- SEG
NO.
_.
_:.
#
12.5
12.5
229
2860
A
34320
247
12929
1125
1651
2
2
6601320
B
15840 _.1
114
153 ...
180 .......
. 7783 _
19.5.
8
..
79
632 ' .....
....
C_ .
7582
_. 133
2852, ...
_ 720
_
531..
19:5
11.5
79
908
C
10898
133
5892
1035
_....I
3_75
,.
8
_.__.
8
_..
_...
165
_..
1320
D
_.-'—114
15840—
- 114
2444
720 1614
12
12...._.:..
73. ..
880
_IE
10560.
76".
-3666 ?
1080
_.
,. 514
1'4
14'-
236
3300
F _
39600
285
-18713 -
1260
1432
STRUCTURAL CALCULATIONS
SHEAR WALL CONSTRUCTION
D112" GYPSUM WALL BOARD APPLIED DIRECTLY TO 2x STUDS WITH STANDARD WALL BOARD
NAILS (1 112'x 0.12 DIAMETER vat 3/8" HEADS) OR 5d COOLER NAILS AT 7" OIC MAX. TO ALL
STUDS, SILLS, PLATES AND BLOCKING. ANCHOR w/ 518" DIAMETER x 10" LONG ANCHOR BOLTS
(vv/3"x 3' x 0.229" THICK PLATE WASHERS BETWEEN NUT AND WOOD SILL) @ 6'-0" 0/C MAX
16" O.C. FRAMING
(ALLOWABLE LOAD. 75 Of - PER CBC 2010 TABLE 2306.7)
D 718" PORTLAND CEMENT PLASTER ON WOMEN WIRE OR EXPANDED METAL LATH NAILED
AT EACH STUD, SILL AND PLATE @ 6" 0,,C MAX. vll No. 11 x ,l Y-.." GALVANIZED NAILS WITH
7116' DIAMETER HEADS OR ATTACHED vj/ No. 16 GAUGE STAPLES HAVING 718' LONG
LEGS. ANCHOR wl 5/8'' DIAMETER x 10' LONG ANCHOR BOLTS 7" EMBED MIN (w/ 3" x 3" x
0.229" THICK PLATE WASHERS -SDC D ,BETWEEN NUT AND WOOD SILL) @ 48" OIC MAX.
16" O.C. FRAMING ,
(ALLOWABLE LOAD: 180 Of- PER 2010 CBC TABLE 2306.7)
THE NEXT THREE (3) SHEAR WALL TYPES SHALL ALL HAVE THE FOLLOWING
IDENTICAL STRUCTURAL I WOOD PANEL DIAPHRAGM: (WALL1 , 2 & 3 ONLY)
3/8° C -D EXPOSURE I APA PLYWOOD OR 3/8` ORIENTED STRAND BOARD APPLIED DIRECTLY
TO THE STUDS. WITH THE LONG DIMENSION OF FULL PANELS LAID PARALLEL OR
PERPENDICULAR TO THE LENGTH OF THE STUDS, ALL EDGES OF EACH PANEL SUPPORTED
ON STUDS, SILLS, PLATES OR BLOCKING AND NAILED AND ANCHORED AS FOLLOWS:
1 1>8d COMMON NAILS @ 6" OIC AT ALL PANEL EDGES AND 8d COMMON NAILS @ 12" OIC AT
ALL FIELDS. ANCHOR WITH 51$" DIAMETER BY 12" LONG ANCHOR BOLTS AT 48" OIC.
(ALLOWABLE LOAD: - 280 olf - PER 2010 CBC TABLE,2306.3) 9
CONSTRUCTION NOTE(S) 1 & 2 APPLY, (NOTES 3, 4 AND 6 APPLY ONLY WHEN
DIAPHRAGM AT BOTH SIDES OF) "
2 D8d COMMON NAILS @ 4 OIC AT ALL PANEL EDGES AND 8d COMMON NAILS @ 12" O/C AT
ALL FIELDS. ANCHOR WITH S18" DIAMETER BY 12" ANCHOR BOLTS AT 32' O/C.
(CALCULATE TO MAXIMUM OF 349 Of PER 2010 CBC TABLE 2306.3) STUDS @16" O.0
CONSTRUCTION NOTE(S) 1 & 2 APPLY (NOTES 3, 4, 5 AND 6 APPLY WHEN DIAPHRAGM
AT 80TH SIDES)
3 b 8d"COMMON NAILS @ 3" OIC AT ALL PANEL EDGES AND 8d COMMON NAILS @ 12`° OIC AT
ALL FIELDS. ANCHOR WITH W" DIAMETER BY 12" LONG ANCHOR BOLTS AT 32'01C.
(ALLOWABLE LOAD: 550 Of - PER 2010 CBC TABLE 2306.3)
CONSTRUCTION NOTE(S) 1, 2,3 & 6 APPLY (NOTES 4 & 5APPLY WHEN DIAPHRAGM AT
BOTH SIDES)
NOTE VALUES ARE APPLICABLE TO DOUGLAS FIR LARCH FRAMING @ 16"'O.0 ;
k
SHEAR WALL CONSTRUCTION
D112" GYPSUM WALL BOARD APPLIED DIRECTLY TO 2x STUDS WITH STANDARD WALL BOARD
NAILS (1 112'x 0.12 DIAMETER vat 3/8" HEADS) OR 5d COOLER NAILS AT 7" OIC MAX. TO ALL
STUDS, SILLS, PLATES AND BLOCKING. ANCHOR w/ 518" DIAMETER x 10" LONG ANCHOR BOLTS
(vv/3"x 3' x 0.229" THICK PLATE WASHERS BETWEEN NUT AND WOOD SILL) @ 6'-0" 0/C MAX
16" O.C. FRAMING
(ALLOWABLE LOAD. 75 Of - PER CBC 2010 TABLE 2306.7)
D 718" PORTLAND CEMENT PLASTER ON WOMEN WIRE OR EXPANDED METAL LATH NAILED
AT EACH STUD, SILL AND PLATE @ 6" 0,,C MAX. vll No. 11 x ,l Y-.." GALVANIZED NAILS WITH
7116' DIAMETER HEADS OR ATTACHED vj/ No. 16 GAUGE STAPLES HAVING 718' LONG
LEGS. ANCHOR wl 5/8'' DIAMETER x 10' LONG ANCHOR BOLTS 7" EMBED MIN (w/ 3" x 3" x
0.229" THICK PLATE WASHERS -SDC D ,BETWEEN NUT AND WOOD SILL) @ 48" OIC MAX.
16" O.C. FRAMING ,
(ALLOWABLE LOAD: 180 Of- PER 2010 CBC TABLE 2306.7)
THE NEXT THREE (3) SHEAR WALL TYPES SHALL ALL HAVE THE FOLLOWING
IDENTICAL STRUCTURAL I WOOD PANEL DIAPHRAGM: (WALL1 , 2 & 3 ONLY)
3/8° C -D EXPOSURE I APA PLYWOOD OR 3/8` ORIENTED STRAND BOARD APPLIED DIRECTLY
TO THE STUDS. WITH THE LONG DIMENSION OF FULL PANELS LAID PARALLEL OR
PERPENDICULAR TO THE LENGTH OF THE STUDS, ALL EDGES OF EACH PANEL SUPPORTED
ON STUDS, SILLS, PLATES OR BLOCKING AND NAILED AND ANCHORED AS FOLLOWS:
1 1>8d COMMON NAILS @ 6" OIC AT ALL PANEL EDGES AND 8d COMMON NAILS @ 12" OIC AT
ALL FIELDS. ANCHOR WITH 51$" DIAMETER BY 12" LONG ANCHOR BOLTS AT 48" OIC.
(ALLOWABLE LOAD: - 280 olf - PER 2010 CBC TABLE,2306.3) 9
CONSTRUCTION NOTE(S) 1 & 2 APPLY, (NOTES 3, 4 AND 6 APPLY ONLY WHEN
DIAPHRAGM AT BOTH SIDES OF) "
2 D8d COMMON NAILS @ 4 OIC AT ALL PANEL EDGES AND 8d COMMON NAILS @ 12" O/C AT
ALL FIELDS. ANCHOR WITH S18" DIAMETER BY 12" ANCHOR BOLTS AT 32' O/C.
(CALCULATE TO MAXIMUM OF 349 Of PER 2010 CBC TABLE 2306.3) STUDS @16" O.0
CONSTRUCTION NOTE(S) 1 & 2 APPLY (NOTES 3, 4, 5 AND 6 APPLY WHEN DIAPHRAGM
AT 80TH SIDES)
3 b 8d"COMMON NAILS @ 3" OIC AT ALL PANEL EDGES AND 8d COMMON NAILS @ 12`° OIC AT
ALL FIELDS. ANCHOR WITH W" DIAMETER BY 12" LONG ANCHOR BOLTS AT 32'01C.
(ALLOWABLE LOAD: 550 Of - PER 2010 CBC TABLE 2306.3)
CONSTRUCTION NOTE(S) 1, 2,3 & 6 APPLY (NOTES 4 & 5APPLY WHEN DIAPHRAGM AT
BOTH SIDES)
NOTE VALUES ARE APPLICABLE TO DOUGLAS FIR LARCH FRAMING @ 16"'O.0 ;
STRUCTURAL CALCULATIONS
4 1>15132" STRUCT. I APA PLYWOOD OR 15132" ORIENTED STRAND BOARD (OSB) APPLIED
DIRECTLY TO THE STUDS, WITH THE LONG DIMENSION OF FULL PANELS PARALLEL OR
PERPENDICULAR TO THE LENGTH OF THE STUDS, ALL EDGES SUPPORTED ON STUDS, SILLS;
PLATES OR BLOCKING AND NAILED AND ANCHORED AS FOLLOWS: 8d COMMON NAILS @ 2"
O1C AT ALL PANEL EDGES AND 8d COMMON NAILS @ 12" OIC AT ALL FIELDS. ANCHOR WITH
DIAMETER ANCHOR BOLTS AT 16" OIC. —STATE EMBEDDED DISTANCE 7" MIN
(ALLOWABLE LOAD: 730 plf — PER 2010 CBC TABLE 2306.3)
CONSTRUCTION NOTE(S) 1; 2; 3, & 6 APPLY (4 AND 5 APPLY WHEN DIAPHRAGM AT
BOTH SIDES)
CONSTRUCTION NOTES:
1 3" x 3" x 0.229" PLATE WASHERS SHALL BE PROVIDED BETWEEN ALL ANCHOR BOLT NUTS
AND THE WOOD SILL.
2 SEE ANCHOR BOLT CALCULATIONS FOLLOWING THESE NOTES IN THE CALCULATIONS.
3 EDGE NAILING AT ABUTTING PANEL EDGES FOR WALLS LOADED IN EXCESS OF 350 plf SHALL
BE APPLIED TO 3x OR WIDER STUDS.
4 APPLYING EQUAL THICKNESS STRUCTURAL WOOD PANELS TO BOTH STUD FACES OF A
SHEAR WALL AND WITH MATCHING NAILING FOR BOTH SIDES SHALL PROVIDE DOUBLE THE
LOAD CAPACITY OF WALLS HAVING THE SAME PANELS AND NAILING APPLIED TO ONLY ONE
FACE. .
5 STRUCTURAL WOOD PANEL SHEAR WALLS WITH PANELS APPLIED TO BOTH FACES AND
WITH'EDGE NAILING LESS THAN 6"O/C SHALL HAVE ABUTTING PANEL EDGES FOR ONE SIDE
OFFSET ONE STUD SPACE FROM THE OTHER SIDE (NOTE No. 3 ALSO APPLIES)
6 ALL SHEAR WALLS HAVING A LOAD CARRYING CAPACITY IN EXCESS OF 350 pif SHALL BE
PROVIDED WITH. 3x. P.T.D.F. SILL PLATES AND 12" LONG ANCHOR BOLTS OF THE DIAMETER
PROSCRIBED FOR THAT WALL CONSTRUCTION TYPE (ALL ANCHOR BOLTS SHALL BE SET T'
INTO CONCRETE)
i WHERE THE CONTRACTOR DESIRES TO CONSTRUCT THE SLAB -ON -GRADE AND THE
FOOTINGS AND FOUNDATION IN A TWO POUR SYSTEM, ALL ANCHOR BOLTS SHALL HAVE A
MINIMUM LENGTH OF 14", SETTING THEM A MINIMUM OF 4" INTO THE TOP OF THE
FOUNDATIONS BEFORE POURING THE SLAB.
S ALL ANCHOR BOLTING, HOLDOWN BOLTS OR STRAPS AND OTHER FORMS OF CONCRETE
INSERTS SHALL BE SECURELY HELD IN PLACE WITH JIGS OR OTHER SUCH DEVISES PRIOR
TO REQUESTING FOUNDATION INSPECTION, DURING INSPECTION AND DURING ACTUAL
POURING OF CONCRETE.
9 ALL ANCHOR BOLTS AND HOLDOWN BOLTS SHALL BE BROUGHT PLUMB PRIOR TO THE
CONCRETE HARDENING. MECHANICAL STRAIGHTENING OF BOLTS AFTER THE CONCRETE
HAS HARDENED THAT RESULTS IN SLAB EDGE BREAKING SHALL RESULT IN REJECTION OF A
PORTION OF THE SLAB AND FOUNDATION BY THE ARCHITECT OR STRUCTURAL DESIGNER
- OF RECORD AS HE DEEMS NECESSARY, ITS REMOVAL AND REPOURING OF THAT PORTION
OF THE CONCRETE.
10 HOLDOWN STRAP HOOKS SHALL BE STABLIZED DURING THE CONCRETE POUR IN ORDER TO
ENSURE THEY REMAIN AT THE MANUFACTURER'S PROSCRIBED ANGLE OF INSERTION. .
11 ATTACHMENT OF A 3x SILLPLATE TO FLOOR FRAMING BELOW SHALL BE MADE WITH THE
USE OF SIMPSON SDS/4x6 WOOD SCREWS AT 3" olc.
12 ATTACHMENT OF A 2x SILL PLATE TO FLOOR FRAMING BELOW SHALL BE MADE WITH THE
USE OF 16d @ SPACING INDICATED AT THE SHEAR WALL TABULATION.
STRUCTURAL CALCULATIONS
PROVIDE 24 IN WIIDE X 24'IN DEEP 6' FT LONG FOOTING
WITH 3# 5 TOP AND BOTTOM CONT.: c
DERIVE GRADE BEAM
ASSUME=_ 2500 Psi
.co
L
3# 5
TOP & BOTT ( :....
► .
LOT
—
LOT T� ;
DATAS:
Lsw, 2 FT Fy=
60 KSI
top &Ybot w
Lauri 2 FT ,Fc=
2500 'PSI
As= 186!in2 + {
_
h= 24 N d
21 IN
8=' 24 IN AS=
0.93 .int 3#'5
As min 0 8064'in2
OVERTURNIG-MOMENT. -
'RESISTING DEAD LOAD:
- - MR ROOF+WALL+GR BEAM w
_ KIP
ROOF & FLOOR='
2500'-° P= 7180 Lb
Mo= 9.5 kip -'i
WALL=
1200 " PU 0.9'P
GR. BEAM=
3480:° PU= ' 6462`Lb
MU 1.4'Mo
,
..
KIP FT.
Mb 13.3
... ...; ...
i
RESISTING MOMENT: L=
6 F
MO=. 95 wIP n
Mr--0.6T-L12
OVERTURNING STABILITY RAT10N
-. -KIP-Ft
Mr 19.386 >
�..
MO= 9.5000 OK'
1 2.04: 1 1 OK 1.5:1
:SOIL BEARING PRESSURE:
e=Mo/P 1.32312 Fr
qmax= 2'P / 3'B'eo <
ALLOWABLE BEARING
eo U2- 1.67688 Fr -
_ _ gmax=_ 1427.254''PSF
PRESSURE 2000 PSF r
FACTORED EARTH PRESSURE:'
I
eu=MU/PI. 2.05819 ft
_. ..
qu_max= 2'p / 3'B'eo
•
_:. qui= qu_max- ( qu_max) (lane)
euo-U2-60.94181 �it F _
,qu_max= » 2287.077 psf
� 3'euo
: qu_p= 668.160 psf
Mu- u Larm^2 . + u_max-_p)
(q
.. q
u arm^2 B
�
Mu 4.831195592.
,
2
.* . 6
kip ft
Vu— qu P + qu max (Larm)'B
Vu_ 5,910.5---.
Ib.
2
REINFORCING STEEL:
AS= 0.93 a=
AS FY 1.1 in
;
0.85 F'C'B
;
Mn= 0.9'As'Fy'(d-a/2) .. -
Mn= 85.59556 kip ft
> 4.83 kip ft OK
Vc=:O 85'2'B'd 2500
Vc= 42.84 kip
> 5.91047+kip OK
PROVIDE 24 IN WIIDE X 24'IN DEEP 6' FT LONG FOOTING
WITH 3# 5 TOP AND BOTTOM CONT.: c
STRUCTURAL CALCULATIONS
FOUNDATION f
i
" t
i
POST
1 � i
f
i
FOOTING.
F 12
18" 4" 18"
.. ....... _. .
w
�'40" X 12" = 480SO IN _3.3333
j144SQIN
SOIL PRESSURE = 1000 `,PSF i
w'TOTAL LOAD =13,300.# :>2600# OK
f
0
FOUNDATION
t �
► SOIL PRESSURE _ 1000 PSF
LOADING
' ROOF =" 35
EXr. WALLS = 15
' H1=+ 13 ft
TYPICAL PERIMETER FOOTING AT s 1 STORY
Trib. Area (ft) � 8
- __ ..�..._._...._ ,LOADING
ROOF
_= _630 #1
195.._._ #1
W= 825 #1
REQ"D WIDTH =: 0.825 FT/' FT LENDTH
12" WIDE x 12" CONTIN P_ERIM_FT,
� ! _
;,AND 2 # 4 BARS, CONTIN ..
STRUCTURAL CALCULATIONS "
5/8" SET -XP EPDXY ADHESIVE ANCHORE ASTEM 193 GRADE B7
hef= 10" 1
calculate static steel stregth tension
per ACI 318-05 sect D 5.1.
1 0 SA N sa = 0.75x 75750 = 56,810
,
5
calculate static concrete breakout
strength in tension
s ^i
.per ACI 318-05 sect D 5.2.
4 `
SA N sa = 0.65x 9600 = 6240#
calculate static pullout strength in__ri
tension per ACI .318-08 SECT D.5_3
as amended in section 4.1.4 of this repost
0 P Na — 0.65x 2517,5 = 16360#
.ACI 318-08 SECT D.4.1.2
0 Nn= 6240# co=1.48