Loading...
11-0561 (AR)P.O. BOX 1504 • 78-495 CALLE TAMPICO -LA QUINTA, CALIFORNIA 92253 c!1 Application Number: 11 X00000561 `Pl;opert Address: 79586—MISSION DR E APN: 602-310-002- - - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL • Application valuation: 65000 Applicant: Architect or Engineer: BUILDING & SAFETY DEPARTMENT - BUILDING PERMIT Owner: CHAD & LINDA MOKLER 79580 MISSION DRIVE EAST LA.QUINTA, CA 92253 Contractor: SANTUCCI BUILDERS INC 72529 BEAVERTAIL STREET PALM DESERT, CA 92260 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 7/ 29/11 l J3g� �� (760)578-775110Z @ ( w LiC. No.: 820801 l LICENSED CONTRACTOR'S DECLARATION - WORKER'S COMPENSATION DECLARATION F:. I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: _ Section7000 of Division 3 of the usiness and Professioppp���Is Code, and my License is in full force and effect. I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License ass B ( License No.: 820801 - for by Section 3700 of the Labor Code, for the performance of the work for which this permit is (x7 `\J issued. Date:" '1i Contractor: o _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor _V Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier DSRT. CRNSTONE Policy Number 23 814 94311 following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the work for which this permit is issued; I shall,nof employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I s uld become subject to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 0/pt./pnp he LaborC d, I shall forthwith mp y wi those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by - �c1\_�.� Jt1\.h.any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500).: Date licant: �+ W� I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure isnot intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE W KERS' C PENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the, I DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or - improve for the purpose of sale.). ' APPLICANT ACKNOWLEDGEMENT (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to'the, 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. - property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1. Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.). whose benefit work is performed under or pursuant to any permit issued as -a result of this application, (_ 1 I am exempt under Sec. , B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quin ta, its officers, agents and employees for any act or omission related to the work being _ performed under or following issuance of this permit. Date: Owner: 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject CONSTRUCTION LENDING AGENCY permit to cancellation.. 'I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that I have read this application and state that the above information is correct. -I agree to comply with all work for which this permit is issued (Sec. 3097, Civ. C.). - - city and co my o�d'anuces and state laws relating to wilding construction, and hereby authorize representatives • of this u y pon the above-mentioned pro rty for inspection purLender's Name: �Date: ignature (Applicant or Agent): Lender's Address: - LQPERMIT ; LQPE%NIIT - Application Number 11-00000561 '. Structure Information Construction Type TYPE V, UNPROTECTED Occupancy Type DWELLG/LODGING/CONG <=10. Other struct info . . . CODE EDITION 2010 1ST FLOOR SQUARE FOOTAGE - 270 00, PermitBUILDING PERMIT Additional desc . Permit Fee 482.00 Plan Check Fee ..-. 313.30 - Issue Date Valuation 65000 Expiration Date 1/25/12. Qty Unit Charge Per Extension BASE FEE 414.50 15.00 4.5000 ------------------------------------------------------------------------------ THOU BLDG 50,001-100,000 67.50 Permit . . . ELECT - ADD/ALT/REM. Additional desc . Permit Fee 24.45 Plan Check Fee 6.11 - Issue Date Valuation 0 Expiration Date 1/25/12. Qty Unit Charge Per Extension BASE FEE 15.00 270.00 .0350 ELEC NEW RES - 1 -OR 2 FAMILY 9.45 ' Permit . . GRADING PERMIT Additional desc . - Permit Fee 15.00 Plan Check Fee .00 Issue Date Valuation . . . . 0 Expiration Date 1/25/12 Qty Unit Charge Per. Extension ----------------------------------------------------------------------------- BASE FEE 15.00 Permit . . MECHANICAL Additional desc . -- Permit Fee . . . . 33.00 Plan Check Fee 8.25 Issue Date . . . . Valuation . . 0 . Expiration Date 1/25/12 Qty Unit Charge Per Extension BASE FEE 15.00 LQPE%NIIT - Application Number 11-00000561 �. Permit . . . . MECHANICAL Qty Unit Charge Per. Extension : 4.00 4.5000 EA MECH VENT INST/ DUCT ALT 18.00 Special Notes and Comments ADDITIONS TO EXISTING SFD. DINING: ` 173SF; OFFICE:.97SF. PER ENGINEERED Ky: �...:� PLANS..2010 CODES -- --------------------------_-------- Other Fees . . . . ... . BLDG STDS ADMIN (SB1473) 3.00 ENERGY REVIEW FEE 31.33 STRONG MOTION (SMI) -RES 6.50 Fee summary Charged Paid Credited Due Permit Fee. Total 554.•45 .00 .00 554.45 Plan Check Total 327.66 .00 .00 327.66 - Other Fee Total 40.83 ..00 .00 40.83 Grand Total .922.94 00. .00 922.94 LQPERA1IT - .. Bin # City of La Quinta Building &Safety Division Permit # P.O. Box 1504, 78-495 Calle Tampico 11 �Q1 La Qulnta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Project Address: /771,ffr0 of Vr- �aS¢ Owner's Name: CtiRl11C/hdq A. P. Number: ('P O a- - 3 /Q — 0 0 a- Address: 177/Jr/0 `► CkJ % Legal Description: i al At, tot 35 %r a9ys - 2 City, ST,Zip: (Q �V�,�jrq Cp 922S' Contractor: (f.�rl. y d Q/� ]�V GG� Telephone: 70 W 00 Address: Project Description: #0610L ffM-r /(J L�ii`�✓fis City, ST, Zip: Telephone: f r-73 f f ee J4.h State Lic. # : City Lic. [.+ 9 7 SF Arch., Engr., Designer: Cwztej 5'4 V e �7Ave-k le e e Address: %d- 0 f0 �ry7�/� iil/ah!/7 IJt. /7► - S City, ST, Zip: Telephone: 7 S Construction Type: Occupancy: G �. State Lic. #: G / 3 ��O Project type (circle one): New (Add Alter Repair Demo Name of Contact Person: CU /--t / J r17 Up IP Sq. Ft.: a 7.9 # Stories: 0 I # Units: Telephone # of Contact Person: 7&0 - C lP % 3 S Y Estimated Value of Project: i0S', VOW APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rccld TRACKING PERMIT FEES Plan Sets � Plan Check submitted61 41 11 Item Amount Structural Calcs. Reviewed, ready fv correction A Plan Check Deposit Truss Calls. Called Contact Person i Plan Check Balance Title 24 Calls. Plans picked up S Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for corrections/issue j is. I{ Electrical Subcontactor List Called Contact Person ; I Plumbing Grant Deed Plans picked up ft I S.M.I. H.O.A. Approval Plans s resubmitted ,ram L% 7 I Grading IN HOUSE:- Review, ready for correction issue J Developer Impact Fee Planning Approval Called Contact Person 'j A,I,P,P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees ICIZZ • q so-rz- 71%Dolt IQ toC 1 /8 b+ Date 7/19/11 No. 31057 Owner chad & Linda Mokler Address 79580 Mlssion Drive E. City La Quinta Zip 92253 Tract # Type Residential Addition CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 APN # Jurisdiction Permit # No. of Units -Wt�,��ra aERMUDA DUNES Cn RANCHO MIRAGE INDIAN WELLS �. PALM DESERT `?+ LA QUINTA ..!Y IND10 : Q i- ~ 602-310-002 La Quinta 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 79580 Mission Drive E 270 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 270 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Curtis Shupe Check No. Name on the check Telephone 760-346-7354 Funding Exempt BY Dr. Sharon P. McGehee Superintendent Fee collected /exemprted by S ro cGilvrey Payment Recd ■ n _ A /i % Over/Under " 211VIL� NOTICE: Pursuant to Government Code Section 66020(d)(1), thiVmll serve to notify you that the 90-day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting Jun 231104:27p RANCHO LA QUINTA HOA 7607778961 p.1 R.-ANCHO LAB QUINTA MASTER ASSOCIATION Arckitectural ControlCommittee May 16, 2011 Mr. Greg Mokler 79 -580 Mission Drive East La Quinta, CA 92253 Re: 79-580 Mission Drive East A oravaa of __ iss- n The Architectural Committee reviewed your submission for an addition to the living room area out to the columns of the residence. The submission as presented is approved Won condltfw The Committee requires the following: + All work is to be done in accordance with all applicable requirements of governmental entities, including the City of La Quinta and in accordance with all Homeowners Association architectural guidelines and governing documents. If applicable, a City of La Quinta building permit be obtained and copy furnished to the Association prior to commencement of work. When the work has been finished, please return "Notice of completion" to the Association Office. The Association's architectural consultant will perform a final inspection after receipt of such notice; when verification► of the approved plan tnodificattions have been concluded, your Security Deposit will be processed for refund. Thanking you in advance and if arty questions please do not hesitate to call me at the on -site office 777.8807. Sincerely, Mary E. Walker, ccw Association General Manager Email: rnwalker drminternet.com cc: Architectural Comm. P.O. BOX 6419 • LA QUINTA, CA 92248-6419 • 760-777-8807 • FAX 760-777-8961 BUILDING ENERGY ANALYSIS REPORT PROJECT: Mokler Residence 79580 Mission Drive East La Quinta, CA Project Designer: Curtis R. Shupe, Architect 72880 Fred Waring Drive Suite A-5 Palm Desert, CA 92260-9374 Report Prepared by: Joan D. Hacker Insu-form, Inc. 77-810 Las Montanas Road, Suite 201 Palm Desert, Ca 92211 7fW--W Lot", Job Number: , Date: 5/2/2011 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE �t 13Y The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Slandards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by Ener vSoft User Number: 2655 RunCode:2011-0S02T16:2I:50 ID: tv,S I TABLE OF CONTENTS I Cover Page Table of Contents Form CF-I R Certificate of Compliance Form MF-1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary 1 2 3 10 13 J EnergyPro 5.1 by EnergySoft Job Number: ID: User Number. 2W5 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Mokler Residence Building Type ® Single Family ❑ Addition Alone O Multi Family ® Existing+ Addition/Alteration ©ate 5IV2011 Project Address 79580 Mission Drive East La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area Z905 Addition 270 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes El No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes El No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features (see Part 2 of 5) Status Slab Unheated Slab -on -Grade None 2,635 Perim = 235' Existing Wall Wood Framed R-13 1,763 Existing Roof Wood Framed Attic R-22 2,635 Existing Roof Wood Framed Attic R-38 270 New Slab Unheated Slab -on -Grade None 270 Perim = 15' New Wall Wood Framed R-13 218 New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Front (S) 12.5 a710 a73 2.0 none Bug Screen Existing Front (S) 225 0.710 0.73 2.0 none Bug Screen Existing Front (S) 30.0 0.710 0.73 2.0 none Bug Screen Existing Front (S) 24.0 0.710 0.73 2.0 none Bug Screen Existing Leff` (M 9.0 0.710 0 73 2.0 none Bug Screen Existing Left (WJ 9.0 0.710 0.73 2.0 none Bug Screen Existing Left (149 20.0 0.710 0.73 2.0 none Bug Screen Existing Leff (W) 60 a710 0,73 2.0 none Bug Screen Existing Leff (W) 6.0 0.710 0.73 2.0 none Bug Screen Existing Leff (W) 6.0 0.710 0.73 2.0 none Bug Screen Existing Rear (N) 30.0 0.710 0.73 2.0 none Bug Screen Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 78•0 AFUE Split Air Conditioner 10.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING City. Type Gallons Min. Eff Distribution Status Err Pro 5.1 by EnergySoft User Number. • 2655 RunCode: 2011-0542T16:24:50 ID: Page 3 of 13 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Mokler Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 5IV2011 Project Address 79580 Mission Drive East La Quinta California Energy Climate Zone Total Cond. Floor Area Addition CA Climate Zone 15 Z905 270 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ® No HERS Measures -- If Yes, A CF-411 must be provided per Part 2 of 5 of this form. ❑ Yes ® No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity ( Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Right (E) 15.0 0.710 a73 2.0 none Bug Screen Existing Right (E) SO 0.710 0.73 2.0 none Bug Screen Existing Right (E) 9.0 0.710 0.73 2.0 none Bug Screen Existing Rear (N) 20.0 0 710 0.73 2.0 none Bug Screen New Rear (N) 15.0 0.490 0.49 2.0 none Bug Screen New Rear (N) 15.0 0.490 0.49 2.0 none Bug Screen New Rear (N) 6.0 0.490 0.49 2.0 none Bug Screen New Rear (N) 16.5 0.490 0:49 2.0 none Bug Screen New Rear (N) - 6.0 0.490 0.49 2.0 none Bug Screen New Rear (N) 200.0 0.490 0.49 2.0 none Bug Screen New Right (E) 24.0 0.710 0.73 2.0 none Bug Screen New HVAC SYSTEMS Q . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status WATER HEATING Q . Type Gallons Min. Eff Distribution Status EnergyPro 51 by EnqEgySoft User Number., 2655 RtwCode. 2011-05-02T16:24.50 ID: Page 4 of 13 PERFORMANCE CERTIFICATE: Residential fart 2 of 5) CF-1 R Project Name Molder Residence Building Type 0 Single Family 0 Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. EnejgyPro 5.1 by Energ ySott User Number: 2555 RunCode: 207T-05-02t46:24.50 1D: Page PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF-1 R Project Name Building Type ® Single Family ❑ Addition Alone Date Mokler Residence 1 ❑ Multi Family ® Existing+ Addition/Alteration 51212011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft? r) Space Heating 7.32 6.58 0.73 Space Cooling 117.70 117.05 0.65 Fans 25.14 24.94 0.20 Domestic Hot Water 27.38 27.38 0.00 Pumps 0.00 0.00 0.00 Totals 177.53 175.96 1.58 Percent Better Than Standard: 0.9 % BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (S)180deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 520 89 Fuel Available at Site: Natural Gas (149 450 56 Raised Floor Area: o (N) 950 309 Slab on Grade Area: Z905 (E) 570 56 Average Ceiling Height: 10.0 Roof 2,905 0 Fenestration Average U-Factor: 0.60 TOTAL: 510 Avera a SHGC: 0.61 Fenestration/CFA Ratio: 17.5 REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Insu-form, Inc. 5%2�2011 Address 77-610 Las Montanas Road, Suite 201 Name Joan D_ Hacker )OALL-Ak"City/State/Zip City/State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 • ed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Curtis R. Shupe, Architect Address 72880 Fred Waring Drive Name Suite A-5 City/state, Palm Desert, CA 92260-9374 Phone%(e 6 344 73 Sq Signed License # Date 1Fr7erqYPro5-1byEner Soft User Number: 2655 RunCode: 2011-05-02T16.24.50 ID: P e 6 dt 13 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Mokler Residence Building Type ® Single Family ❑ Addition Alone 0 Multi Family ® Existing+ Addition/Alteration Date 51212011 OPAQUE SURFACE DETAILS Surface T e Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 LocatioNComments CavityExterior Frame Interior Frame Slab 2.6351 0.730 None 1 0 180 Existing •4.4.7 Al Existing Living Wall 431 0.102 R-13 180 90 Existin 4.3.1-A3 Existing Livin Wall 394 0.102 R-13 270 90 Existin 4.3.> A3 Existing Living Wall 520 0.102 R-13 01 90 Existing 4.3.1A3 Exisft Livin Wall 418 0.102 R-13 901 90 Existin 4.3.1-A3 Existin Livin Roof 2,635 0.043 R-22 1801 0 Existin 42.1 A6 Existing Livin Wall 170 0.102 R-13 0 90 Remav 4.3.1-A3 Existing Living Roof 270 0.025 R-38 180 0 New 4.2.1-A21 Addition Slab 270 0.730 None 0 180 New 4.4.7 Al Addition Wall 122 0.102 R-13 0 90 New 4.3.1-A3 .Addition Wall 96 0.102 R-13 90 90 New 4.3.1-A3 .Addition FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGCz Azm Status Glazing Type Location/Comments 1 Window 12.5 0.710 Default 0. 731 Default 180 Existing Double Metal Clear Existing Living 2 Window 22.5 0.710 Default 0. 731 Default 180 Existing Double Metal Clear Existing Living 3 Window 30.0 0.710 Default 0. 731 Default 180 Existing Double Metal Clear Existing Living 4 Window 24.0 0710 Default 0.73 Default 180 Existing Double Metal Clear Existing Living 5 Window 9.0 0.710 Default 0.73 Default 270 Existing I Double Metal Clear Existing Living 6 Window 9.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 7 Window 20.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 8 Window 6.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 9 Window 6.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 10 Window 6.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear ,Existing Living 11 Window 5.7 0.710 Default 0.73 Default 0 Removed Double Metal Clear Existing Living 12 Window 140.0 0.710 Default 0.73 Default 0 Removed Double Metal Clear Existing Living 13 Wndow 6.8 0.710 Default 0.73 Default 0 Removed Double Metal Clear Existing Living 14 'Window 31.5 0.710 Default 0.73 Default 0 1 Removed Double Metal Clear Fxisling Living 15 Window 9.0 0.710 Default O. 731 Default 0 Removed Double Metal Clear Existing Living 16 Window 30.0 0.710 Default 0.73 1 Default 0 Existing Double Metal Clear Existing Living (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2) SHGC T 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade T e SHGC Window Ove hanq Left Fin Right Fin H t Wd Len I Hot LExt REx1 Dist Len H t Dist Len Hot 1 Bug Screen 0.76 2.5 5.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 4.5 so 2.0 01 2.0 2.0 3 Rug Screen 0.76 5.0 6.0 2.0 0.1 2.0 2.0 4 Elug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 3.0 3.0 2.0 0.1 2_0 2.0 6 Sug Screen 0.76 3,01 3.0 2.01 0.1 2.01 2.0 7 Bug Screen 076 5.01 4.0 20 01 20 20 8 ligug Screen 0.76 3.0 2.0 2.0 0.1 2.0 2.0 9 j9ya Screen 0.76 3.0 2.0 2.0 0.1 2.0 2.0 10 By Screen 0.76 3.0 2.0 2.0 0.1 2.0 2.0 11 BugScreen 0.76 1.5 3.9 2.0 0.1 2.0 2.0 12 BugScreen 076 10.0 14.0 2-0 0-1120 20 13 19u Screen 0.761 1.5 4.5 2.0 0.1 2.0 2.0 14 p3ug Screen 0.76 7.0 4.5 2.0 0.1 2.0 2.0 15 19u Screen 0.76 2.0 4.5 2.0 0.1 2.0 2.0 18 113ug Screen 0.76 5.01 6.0 2.0 0.1 2.0 2,0 EnergyPro 5.1 by EnergySoft user Number: 2655 RunCode: 2011-05-02T16.,24.50 1D: page 7 of 13 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF-1 R Project Name Building Type O Single Family ❑ Addition Alone Mokler Residence ❑ Multi Family ® Existing+ Addition/Alteration Date 5/2/2011 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 20.0 0.710 Default 0.73 Default 0 Removed Double Metal Clear Existing Living 18 Window 15.0 0.710 Default 0.73 Default 0 Removed Double Metal Clear Existing Living 19 Window 15.0 0.710 Default 0.73 Default 0 Removed Double Metal Clear Existing Living 20 Window 15.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Emsbng Living 21 Window 8.0 0.710 Default 0.73 Default 1 90 Existing I Double Metal Clear Existing Living 22 Window 9.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Existing Living 23 Window 20.0 0.710 Default 0.73 Default 0 New Double Metal Clear Addition 24 Window 150 a490 NFRC 0.49 NFRC 0 New Milgard Addition 25 Window 15.0 0490 NFRC 0.49 NFRC 0 New Milgard Addition 26 Window 6.0 0.490 NFRC 0.49 NFRC 0 New Milgard Addition 27 Window 16.5 0.490 NFRC 0.49 NFRC 0 New Milgard Addition 28 Window 6.0 0.490 NFRC 0.49 NFRC 0 New Milgard Addition 29 Window 200.0 0.490 NFRC 0.49 NFRC 0 New Milgard Addition 30 Window 24.0 0.710 Default 0.73 Default 90 New Double Metal Clear Addition (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value (2) SHGC T De: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hanal Left Fin Right Fin H t Wd Len Hgt LExt RExt Dist Len Hat Dist Len Hot 17 Bug Screen 0.76 a o 2.5 2.0 0.1 2.0 2.0 18 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 19 .Bug Screen 0.76 5.0 3.0 2.0 01 2.0 2.0 20 .Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 21 Bug Screen 0.76 4.0 2.0 2.0 0.1 2.01 2.0 22 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 20 23 Bug Screen 0.76 8.0 25 2.0 01 20 20 24 ,Bug Screen 0.76 5.0 ao 2.0 01 2.0 2.0 25 Byq Screen 0.76 5.0 3.0 2.0 0.1 2.0 20 26 Bug Screen 0.76 4.0 8.0 2.0 01 2.0 2.0 27 Bug Screen 0.76 1.5 11.0 2.0 0.1 2.0 2.0 28 By Screen 0.76 1.5 4A 2.0 01 2.0 20 29 Bug Screen 0.76 10.0 20.0 2.0 0.1 2.0 2.6 30 18u Screen 0.76 8.0 3.0 2.0 01 2.0 2.0 EnergyPro 5.1 U Ener Soft User Number., 2655 RunCade. 2011-05-02T16:24:50 ID: Page 8 of 13 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5) CF-1 R Project Name Building Type @ Single Family ❑ Addition Alone Mokler Residence ❑ Multi Family ® Existing+ Addition/Alteration Date 5/2(2011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft Volume Year Built New Exislina Altered Removed Living Zone Existing Living 2,635 26,350 1981 Addition 270 2,700 Totals 270 2,6351 Q 0 HVAC SYSTEMS System Name City. Heating Type Min. Eff. Cooling Ty2e Min. Eff. Thermostat Type Status Living Zone 2 Central Furnace 78•0 AFUE Sprit Air Conditioner 10.0 SEER Setback Existing HVAC DISTRIBUTION Svstem Name Heating Cooling Duct Location Duct R-Value Ducts Tested? Status Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing 13 13 13 WATER HEATING SYSTEMS S stem Name oty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 3 Small Gas No Pipe Insulation 40,000 50 0.53 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft) � ,o m a ¢ — System Name Pipe Length Pipe Diameter Insul. Thick. Oty. HP Plenum Outside Buried 13 13 13 13 EnergyPro 5.1 by EnergySoft User Number: 2655 RunC'ode: 2011-05-02T16:24:50 ID: Page 9 of 13 MANDATORY MEASURES SUMMARY. Residential (Page 1 of 3 MF-1 R Project Name Mokler Residence Date 1 51212011 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or In this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient (SHOC), and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118 a : Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Root is specified on the CF-1 R Form. * 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. * 150(c): Minimum R-13 insulation in wood -frame wall orequivalent U-factor. * 150 d : Minimum R-13 insulation in raised wood -frame floor or equivalent. U-factor. 150 : Air retarding wrap is tested labeled and installed according to ASTM E1677-95(2000) when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 permAnch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas AEpliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, ❑ erable, and light -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pumpisolation valve and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h). Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. i 50 i : Healing systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150 ' 3A: Insulation is protected from damage, including that due to sunl' ht moisture, equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. Ene►gyPro 5.1 by Energy5oft User Number: 2655 RunCode: 2011-05.02T16:24:50 ID: Page 10 of 13 MANDATORY MEASURES SUMMARY. Residential (Page 2 of 3 MF-1R Project Name Date Mokier Residence 5/2/2011 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 114 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSUASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and S a Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150( : Residential pool systems or equipment meet the pump sizing, flow rate, piping, fifters, and valve requirements of §150( ). Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminalre as specified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shaft be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of 150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 51 by EnergySoft user Number. 2655 RunCode: 2011-05-02T16:24:50 ID. Page 11 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date Mvkler Residence 1 5/2/2011 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to Comply with §150(k)11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficac luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to 130 d . §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130 131, 134, and 146. §150(k)i6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2011-05-02Ti6:24:50 ID: Page 12 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Mokler Residence Date 5/2/2011 System Name Living Zone Floor Area 2,905 ENGINEERING CHECKS SYSTEM LOAD Number of S tems 2 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 1,572 0 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per Systern 70,000 43,799 3,652 848 43,632 Total Output Btuh 140,000 0 Output Btuh/ ft 48.2 3,714 3,100 Cooling System o 0 Output per System 48,0001 0 01 0 0 Total Output (Btuh) 96,000 0 3,714 1 51,227 3,652 0 Total Output Tons 8.0 3,100 Total Output Btuh/ 33.0 Total Output on 363.1 49,832 Air System__ CFM per System 1,3001 HVAC EQUIPMENT SELECTION Airflow cfm) 2,600 Existing HVAC 79,867 0 140,000 Airflow cfm/ ft 0.90 Airflow cfm/Ton 325.0 140,000 F Jan 1 AM Outside Air iN 0.0 % Total Adjusted System Output 79,867 0 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM Outside Air cfm/ ) 1 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMErRICS Airstream Temperatures at Time of Hoofing Peak 26 OF 69 OF 69 OF 119 OF — b—&= Outside Air 0 cfm Supply Fan Heating Coil 2,600 oft 69 OF AK -T TT 118 OF ROOM 70 OF COOLING SYSTEM PSYCHROMETICS JAIrstream Teme2rotureS at Time of Coolie Peak 112/78OF 7 - - - - Outside Air 0 cfm 79 / 61 OF 79/61OF 50/49OF D Supply Fan Cooling Coil 2,600 afrn No - 35.5 % 52 / 50 OF ROOM 78 / 60 OF EnergyRv 5,1 by EnergySoft User Number 2655 RunCode: 2011-05.02T16:24:50 ID: Page 13 of 13