Loading...
AR (07-3119)P.O. BOX 1504 78-495 CALLE TAMPICO LA. QUINTA; CALIFORNIA 92253 INN Application Number: 07-000.03119 Property Address: - 79910 MISSION DR E APN: 1 649-750-010- - - Application description: ADDITION - RESIDENTIAL Property Zoning: . LOW DENSITY RESIDENTIAL Application valuation: — - 36987 M BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: BILL DEAKYNE 79910 MISSION DRIVE EAST LA QUINTA, CA 92253 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 4/15/08 Contractor: A Applicant: Architect or Engineer: EDWARDS CONSTRUCTION IN OB HAR 51455 DESERT CLUB DRIV ( % A I LA QUINTA, CA 922S3,.08 `O08 to Iv �� (760) 777-8202 Lic. No.: 684857 �CE QU1Nl 1 ► _ �FpT A ? ------------------ LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License lass•.,,$ License No.* 57 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is _ _�—1 _ - _ - issued. ' CDate: 1 t Contracto . - _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor — Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier GRANITE STATE Policy Number WC 555-61-55 following reason (Sec. 7031..5, Business and Professions Code: Any city or county that requires a permit to— I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I should become subject to the workers' compensation provisions of. Section _ License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 3700 of the Labor Code, I shall forthwith comply with those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by _ - _ y�6-V any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: Date: JS d Applicant: _ (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and - the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL , Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 — I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.l. (—) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued -(Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERA11:T APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, . the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that 1 have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state la dating-te-brrelg constru �oses��es of this c my jp enter upon ove-mentioned y for ur (/ J Date: % Signature IApph Application Number . . . . . 07-00003119 ------ Structure Information 425SF ADDITION W/135SF CART GARAGE ----- .Other struct info . . . . . CODE EDITION 2001/2004/2005 # BEDROOMS 1.00 FLOOD ZONE NO GARAGE SQ FTG 135.00 1ST FLOOR SQUARE FOOTAGE 425.00 'Permit BUILDING PERMIT Additional desc . Permit Fee 330.00 Plan Check'Fee 214.50' Issue Date . . . Valuation . . 36987 Expiration Date 10/12/08 Qty Unit Charge Per Extension I BASE FEE 252.00 12.00 6.5000 ---------------------------------------------------------------------------- THOU BLDG 25,,001-50,000 78.00 Permit ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 32.58 Plan Check Fee 8:15 Issue Date' Valuation . . . . 0 Expiration Date 10/12/08 Qty Unit Charge Per, Extension BASE FEE 15.00 425.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 14.88 135.00 .0200 ------------------------------------------------------------------------------ ELEC GARAGE OR NON-RESIDENTIAL 2.70 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 44.00 P1an.Check Fee 11.00 Issue Date . . . . Valuation . . . . 0 Expiration Date 10/12/08 Qty Unit Charge 'Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 4.5000 EA MECH VENT I.NST/ DUCT ALT 4.50 1.00 9.0000 EA MECH B/C <=3HP/100K BTU' 9.00 1.00 6.5000 - - - - - - - - - - - - - - - - - - - - - - - - - - EA MECH VENT FAN - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6.50 - - - - - - - - - - - Permit . . . PLUMBING Additional desc . LQPERMIT `Application Number . . . . . 07-00003119 - - - - - --- .00 Permit PLUMBING 245.65 .00 Permit Fee 48.00 Plan Check Fee 12.00' Issue Date . . . . .00 Valuation 0 ' Expiration Date 10/12/08 .00 725.37 Qty Unit Charge Per Extension BASE FEE 15.00 4..00 6.0000 EA PLB FIXTURE 24.00 1'. 00 3.0000 EA PLB WATER INST/ALT/REP 3.00 2.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 6.00 -----7------------------------------------------------------- S ecial Notes and C mm nt p o e s 425SF ADDITION TO CASITA W/135 SF CART GARAGE/V-NR/RES-3/CLASS A (ENGINEERED) THIS PERMIT DOES NOT INCLUDE.BLOCKWALLS 2001 CBC, CPC, CMC, 2004 CEC, 2005 ENERGY. February 'll, 2008 8:58:27 AM AORTEGA ---------------------------------------------------------------- Other Fees . . . . . .ENERGY REVIEW FEE 21.45 STRONG.MOTION (SMI) - RES 3.69 i Fee summary Charged Paid• Credited Due Permit Fee Total -- 454.58 - - - - - ----- .00 - - - - - --- .00 --- - - - - - - 454.58 Plan Check Total 245.65 .00 .00 245.65 Other Fee Total 25.14 .00 .00 25.14 Grand Total 725.37 .00 .00 725.37 LQPERMIT Bin # 110 City of La Quinta Building Bt Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777.7012 Building Permit Application and Tracking Sheet Permit # PmjectAddress: - 'SSTOnI Ill'? �� tS7� Owner's Name: j3`[ L DEA k yN r A. P. Number: 6 02-34o_ OlO Address: %9 - 9 o A S_ i oN P2 i V>: eA S T Legal Description: L -o T 3N F 2 Contractor: EDTNTkRDS CONSTRUCTION INC, 'BOB Address: 51455 DESERT CLUB DRIVE City, ST, Zip:'LA (L Telephone: a< Project Description: LA QUI TA City, ST, Zip: lid r7 O To Q9 s 777-8202 Ex4102R1,.. Telephone:$ ',.4 r~S%r r�Ti9 OF State Lic. # : 684857'iy Lie. #, 272 Engr., Designer.. �e F� y n✓G S aV71 AAJ '17 28 �t`,ecArch., AIL Address: 7 City., ST, Zip: A L Lo/c—, —CA 9ZZ� Telephone: - 3 5- State Lic. #: :.. e Construction T Occupancy: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: Ed Randall Sq. FL: # Stories: #Units: Telephone # of Contact Person: 777-8202 Ext 102 Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Plan Sets Req'd Recd TRACKING Plan Check submitted t Z p PERAW FEES Item Amount Z Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs• Called Contact Person Plan Check Balance Z Tide 24 Calcs.r� Plans picked up Construction Flood plain plan Plans resubmitted I J Mechanical Grading plan 20° Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- 'A Review, ready for corrections!wsue Developer Impact Fee Planning Approval Call rson---,\ ALP P. Pub. Wits. Appr Date of permit issue 1� School Fees Total Permit Fees it — z %* - ues �,� 08 1 CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms RoadBERMUD �! Q A DUNES r rn RANCHO MIRAGE �. Date 4/14/08 La Quinta, CA 92253 INDIAN WELLS (760) 771-8515 r` PALM DESERT No. 29994 LA QUINTA QINDIO p Owner Deakyne APN # 649-750-010 Address 79910 Mission Drive East Jurisdiction La Quinta City La Quinta Zip Permit # Tract # No. of Units 1 Type Residential Addition Lot # No. Street S.F. Lot # No. Street S.F. Unit.1 79910 Mission Drive East 425 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified'School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 425 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Ed Randall Check No. Name on the check Telephone 777.8202 Funding Exempt BY Dr. Sharon P. McGehee Superintendent Fee collected /exemplpd by Shaf Signature Payment Recd i Y X6 4. p $®.00 JOver/Under 0 NOTICE: Pursuant to Government Code Section 66020(d)(1), this will rve t notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which ftxrbuilding or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the Distdct('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant ' Copy - Applicant/Receipt Copy - Accounting TITLE 24 REPORT Title 24 Report for: DEAKYNE RESIDENCE LA QUINTA, CA CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCT ON DA � _Project Designer t - MR. DEAKYNE LA QUINTA, CA - Report Prepared By: ADRIANA GIL Adriana Gil 74-854 Velie Way Ste. #8 Palm Desert,, CA 92260 (760) 404-7917 Job Number: ADY665-0207 Date: 2 �p0a 1/15/2008 - The /15/2008.The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: ADY665-0207 User Number: 5553 Certificate Of Compliance: Residential = (Part 1 of 4) CF -1 R _DEA KY_N.E_RES-IDENCE ❑ Multi Family [X] Existing + Add/Alt Existing Floor Area : ` ` BuildingFront Orientation: - 1./_1.5L2Q08 ' Project Title Fuel Type: Natural Gas' Slab on Grade Areit: -ft2 844 Date c Q-U1NTA Average CeilingHeight: R 10.0 • ft ' Area: -135 ft2 -LA Project Address s 1.00 Ratio: 16.0% Building Permit # - Adr_iana Gil BUILDING ZONE INFORMATION ' " •' # of, � ., • •- Thermostat _ "� '. Vent (760) 404-7917 Documentation Author - • - Telephone Plan check/Dated .. -Enerq- 2 n ' C -`'� • .A Cli.mate_Zo.ne 1.5 - .. Field Check/Date CompliNrfce Method - Climate Zone ' TDV Standard -Proposed Compliance •, _ .', (!@tu/sf-yr) Design Design Margin ' 41.9_ _0.0.42_ Space Heating 4.09 4.20 Y -0:11 A. Existing' Space Cooling 87.87 84.29' - - 3.58 a `� Fans 12.61 .12.10 0.51 ' - `i' ` .. Domestic Hot Water 0.00 0.00. - 0.00.` Pumps 0.00' . , 0.00 F, 0.00 28A4 - Totals 104:57, • ' 100.59 3.98 �X Percent better than Standard: __A2 09 3.8% Wall_ Wood_ Building Type:, FX� Single Family ❑AdditionTotal Conditioned. Floor Area:;844 ft2 ❑ Multi Family [X] Existing + Add/Alt Existing Floor Area : �. ; w ; 419 ft2 BuildingFront Orientation: (SW) 225 deg Raised Floor Area ti , 0 ft 2 Fuel Type: Natural Gas' Slab on Grade Areit: -ft2 844 Fenestration: - Average CeilingHeight: R 10.0 • ft ' Area: -135 ft2 Avg U:• 0.47 Number of Dwelling Units,_ 1.00 Ratio: 16.0% Avg. SHGC- 0.33 Number. of Stories: t BUILDING ZONE INFORMATION ' " •' # of, � ., • •- Thermostat _ "� '. Vent Zone Name Floor Area Volume % Units Zone Type Type. ; Hgt. Area -HVAC -Split -System = 84.4. _8,_4-40 1..00- Conditioned_ -4' '=Setback- 2 -n/a z OPAQUE SURFACES.Insulation Act: Gains Condition r Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y / N .-Status JA IV Reference: Location / Comments _Roof_ Wood_ 41.9_ _0.0.42_ -R-22_ -R=0.0- -• 1.80_ 18 K ❑ Existing_, -0-1--A-1.5 Existing' Wall_ Wood.- = - 11.5_ _0.11.0_ -R_11. _R_0 0_ -4.5--'9.0'1--I ❑Existing .; -'_09_A2 •.Existing ' / all- Wall_ Wood_ 1.8.9_ _0.11.0_ =R_11. _R-0.0_ 1.35_ 9.0. [X ❑Existing_ .09.A2 R Existing- 2.4_'_0.500__None__R=0.0__1.35__9.0 IX ❑Existing_ 28A4 - Existing Wall_ Wood_ 1.01. _0.11.0_-R_11.=R= 0.0__225__9.0 �X ❑Existing_ __A2 09 '.Existing Wall_ Wood_ 3.7.0_ =0 110_ _R_11 -R 0 0. _31.5__9.0 '[X ❑Existing-` _09=A2 +' , Existing .Roof Wood_ 425_ _0 042_ _R22_ _R 0.0_-1.80_ � 1.8 [X ❑New ' ^ .01=A15 ' ••Addittion Wall_ Wood_ - - 20.4_ _0.074-_R_19__R_0.0__225__90 [X ❑New .09-A5 :Addittion = - _Door_ None_ 2.4_ _0.500_ _None_ _R=0.0_ _225_=9.0 [X ❑New 28=A4 ` Addittion ' Wall_ W00 -d_1.6.5_ _0.0Z4_•_R_19__R=0.0__1.35__90 �X ❑New - ' _09=A5 Addittion ` Wall_ Wood- 236_ _0.074_ _R_19_ _R=0.0_ 45__90 0 _09yA5 O New - °Addittion - IF 1:1 El c El F-1 El ❑ ❑,❑ - _ __ E] Ruh Run Initiation Time: 01/1510821:24:40 Run Code: 1200461080 EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number ADY665-0207 ' ' Page: 3 of 9 - "- .. .fr - '. *+.. .. b �� •�..;• �. `_ ..y ., �.! .+. .fir' Certificate Of Compliance : Residential f (Part:2 4) CF R of -1 DEAKYNE RESIDENCE 1/15/2008 ' Project Title * Date "•' - FENESTRATION SURFACES True Corid. ''"' ' Location/ # Type = Area U -Factor.' SHGC2 Azm.Tilt : Stat. Glazing Type '.; . Comments' 1_' Window -Rear -(NE) _20..0_ _0..65.0 -NERC _0.40 -NERC _4.5_ _90- Existing-DEFAU.LT_DBL_P_A NE _Existing • -^ f 2 Window Right (SE)_ 2.0 0.650 NFRC 0_40 NFRC 135 90 Existing_ DEFAULT DBL PANE t Existing ' 3 - Window • Front (SW) 24.0 0.650 NFRC 0_40 NFRC 225 90 Existing -DEFAULT DBL PANE _ Existing ..`' 4 Window Front (SW) 15.0 •0.340 NFRC 0_28 NFRC 225 •90 New BETTER BUILT Vinyl low E, .. "Addittion. 5 Window Front (SW) 15.0 0.340 NFRC 0_28 NFRC 225 `' 90 New ' BETTER BUILTVinyl low E Addittion = .. ' 6 Window Front (SW); 30.0 0.340 NFRC 0_28' NFRC 225 90 New BETTER BUILT Vinyl low E Addittion' 7 Window Rear(NE)8 9 _0650 NFRC 0.48 NFRC 45 f 90 New WECK, GLASS BLOCK Sx8x4 . •Addittion 8 Window Rear (NE) -10.0 0.340 NFRC 0_28 NFRC .45-. 90 New BETTER BUILT Vinyl low E Addittion 9 Window Rear (NE)r10 0 _0 340 NFRC 0 28 NFRC 45 90 New BETTER BUILT Vinyl low E -Aft ttion • t c 1. Indicate source either from NFRC or Table 116A. '2. Indicate source either from NFRC or Table 11613.1 INTERIOR AND EXTERIOR SHADING $' "_Window - • . Overhang •. Left Fin. Right Fin # Exterior Shade Type ShiGC Hgt. Wd. Len...` Hgt. LExt: REAS, Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 5.0 4.0 ', 2.0 0.1 2.0 2.0-:r, 2 Bug Screen 0.76. 4.0 6.0 2.0 -: 0.1 2.0 ' . 2.0 3 Bug Screen -0.76 4.0 6.0 '� -2.0 0.1 2.0 2.0:: . 4 Bug Screen. 0.766_0r 2.5 2.0" _01 -2.0 _2 V' Y 5 . Bug Screen -0.76 6.0 2.5 ' '4 2.0 --0.1 -• 2.0 2.0L"sr 6 Bug Screen t 0.76 -_60 50 f = •2.0`._01 _2.0 2t0 , 7 Bug Screen' 0.76 3.3 ' 2.7 , - - 2.0 '. 0.1 2.0 2.0 8 . Bug Screen .. 0.76 5.0 - 2.0 2.0 " 0.1 �2.0 2.0 .. •�._.,, ',N r F 9 `Bug Screen • 0.76 5.0 2.0 2.0' 0.1. ` 2.0 2.0 r THERMAL MASS FOR HIGH MASS DESIGN Area Thick Heat Inside '`Condition Location/ Type (sf), .. (in.) Cap. Cond. R -Val. JA IV Reference Status, Comments PERIMETER LOSSES 'Insulation Condition Location/ ;r TypeLength R -Val. Location JA IV Reference, Status Comments r Slab Perimeter 70 None No Insulation 26-A1 Existing Existing ' E� Slab Perimeter 70 _ None No Insulation.. 26-A1 ,' i' .. New - Addittion .- • Run Initiation Time: 01/115/0821:24:40... Run Code: '1200461}080 ' �' :''w ` EnergyPro 4.4 by EnergySoft w. User Number: 5553 • , Job Number: ADY665-0207 _ - Page -:4 of 9 t 1 , .+, � r .•'� � • Lam' r. 4 ... , , • Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R DEAKYNE RESIDENCE 1/15/2008 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat' Location Type Eff Type Eff Status Type HVAC Split System Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. Th signed recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, buildin envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer o Oirner (per Busines Professions Code) Documentation Author _ _ _ _ Name: I ADRIANA GIL Title/Firm: MR. DEAKYNE _ _ _ _ _ _ _ _ _ Title/Firm: Adriana Gil Address: 7 . �� 1 _ _ '+NV1 Address: 74-854 Velie Way Ste. #8 LA QUINTA, CA Palm Desert, CA 92260 Telephone:_p Lic. #: Telephone: 7 _ 404-7917 (_ / (signatur — - - (date) (si lure) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) I (date) HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct Condition R -Value Status Ducts Tested? HVAC Split System Ducted Ducted Attic 6.0 New Yes Hydronic Piping Pipe Pipe System Name Length Diameter WATER HEATING SYSTEMS Water Heater System Name Type Insul. Thick. Distribution Rated Tank # in Input Cap. Syst. (Btu/hr) (gal) Energy Condition Factor Status or RE Tank Insul. Standby R -Value Loss (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Control # HP Type Hot Water Piping Length ft) In Plenum Outside Buried Add 1/2" Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. Th signed recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, buildin envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer o Oirner (per Busines Professions Code) Documentation Author _ _ _ _ Name: I ADRIANA GIL Title/Firm: MR. DEAKYNE _ _ _ _ _ _ _ _ _ Title/Firm: Adriana Gil Address: 7 . �� 1 _ _ '+NV1 Address: 74-854 Velie Way Ste. #8 LA QUINTA, CA Palm Desert, CA 92260 Telephone:_p Lic. #: Telephone: 7 _ 404-7917 (_ / (signatur — - - (date) (si lure) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) I (date) Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R DEAKYNE RESIDENCE 1/15/2008 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies oaseo on the adequacy or the special Jusoncation ana documentation submitted. Plan7 Field The Roof "R-38 Roof (R.38x14.24)" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. The Existing Wall 'Wall/Rea r1NE, 1 3.5'xl 0 has a Ll -Factor greater than the Table R3-11 CEC Default Vintage Values. The Existing Wall "Wall/Right/SE,21.5'x10"' has a LI -Factor greater than the Table R3-11 CEC Default Vintage Values. The Existing Wall "Wall/Front1SW,12.5'x10"' has a Ll -Factor greater than the Table R3-11 CEC Default Vintage Values. The Existing Wall "Wall/LeftJSE,37'x10"' has a Ll -Factor greater than the Table R3-11 CEC Default Vintage Values. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a �..., ry oPPONwv� W� g"y a,i,.,Wi - �OLW1I 11JW.IVU*. Plan Field The HVAC System "HVAC Split System" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC Split System" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: ADY665-0207 Page:6 of 9 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑X ❑ § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ �§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ O ❑ apply to exterior mass walls). �§ 150(d): Minimum R-13 raised floor insulation in framed Floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑X ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑X ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include El N El Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. ❑ ❑ ❑ 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ❑ ❑x ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑, ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ • ❑X ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: ADY665-0207 Page:7 of 9 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (`) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ Q ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a miriumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system . that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ❑X ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ❑X ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑X ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ LhJ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ [i] ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ 0 ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ 7 ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑X ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ Q ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ Q ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled ❑ ❑ ❑ by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ 0 ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s).certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: ADY665-0207 Page:8 of 9 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE DEAKYNE RESIDENCE 1/17/2008 SYSTEM NAME FLOOR AREA HVAC Split System 844 Number of Systems 1 Heating System Output per System 32,000 Total Output (Btuh) 32,000 Output (Btuh/sgft) 37.9 Cooling System Output per System 30,400 Total Output (Btuh) 30,400 Total Output (Tons) 2.5 Total Output (Btuh/sgft) 36.0 Total Output (sgft/Ton) 333.2 Air System CFM per System 1,000 Airflow (cfm) 1,000 Airflow (cfm/sgft) 1.18 Airflow (cfm/Ton) 394.7 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions JEATING SYSTEM PSYCHROMETRICS 26.0 of 68.7 of 68.7 of 4 94 Outside Air 0 cfm 68.7 of COOLING SYSTEM 111.0 / 77.6 of Outside Air 0 cfm 77.4/64.9 of Total Room Loads Return Vented Lighting Return Air Ducts. Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 1,005 16,966 2,346 617 17,973 0 - 1,540 1,431 0 0 -0 0 0 0 0 0 0 1,5401 1,431 20,047 2,346 20,835 York H4DH030/P4HUB12LO32 U&H 19,971 7,183 32,000 Total Adjusted System Output 19,971 7,183 32,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 'earn Temperatures at Time of Heatina Peak1 98.7 of Supply Fan Heating Coil 1000 cfm - ROMETRICS (Airstream 1 77.4 / 64.9 of 77.4 / 65.0 of 0 Return Air Ducts .ratures at Ti 58.7 / 57.7 of Supply Fan Cooling Coil 1000 cfm K. Return Air Ducts 4 Supply Air Ducts 97.4 of ROOMS 70.0 of Supply Air Ducts 7 60.1 / 58.2 of 54.1%o R.H. ROOMS 76.0/64.5OF � I EnergyPro 4.4 by Energysoft User Number: 5553 Job Number: ADY665-0207 Page:9 of 9 Y y •, � ,�. - . t, ',� �' .�^r+` -_. = � rt 11 .•fir /.{ OUSTON, LU M B ER, CO M PANY, Lumbermen'Since 1884" r t { 84=391 Cabazon Road r Indio, `CA-92201 CITY OF LA.:QUINTA ('760) 347=8320 Q �� . BUILDING &SAFETY DEPT. APPROVED •Fax: (760) 34`7-8515 '• . r 2 F R CONST TION 'JAN. 5 . zoos t VDq h ' r `S { HANGER I FGFNf) SYMBOL CAPACITY (LBS). B.C. I USP SIMPSON I �� 805 (DF) 675 (SPF) IXXX IJUS24 ILUS24 I 2540 (SPF) I XXX I THD26 I HUS26 I 12100 (SPF) I XXX I HJH26L/R I THJA26 I p 12645 (SPF) I XXX I THD26-2 I HHUS26-2 I •- 14055(SPF) I XXX I THD28-2 I HHUS28-2 I 14930 (DF) I XXX I THDH26-3 I HGUS28-3 I h �53 64 � 1155 (DF) XXX I MSSH217 I THAS218 I I ,� 112000(LSL) I XXX I THGBH3 I GT3T8B I NOTE: OPEN END JACKS LESS THAN 8'-0' REQUIRE (3)12d TOE- NAIL @ T.C. 8 (3)124 TOE- NAILS @ B.C. PER STANDARD DETAIL L.1 O O � O ` 2 m � ? � J � � h J L1 � y � z N 6¢ °< �O O 2:9 8 ua h �53 64 � gz 4� C C O8F 0 O W 0 ' eY5 O 2 O O � O ` 2 m � ? � J � � h J L1 � N -R N 0] � O W 0 O 0) O m 0 O � cD F O "R� • The A.C. Houston Lumber Company's Truss Warranty Project Name: DEAKYNE RESIDENCE Date of Issue: 01-14-08 This document shall be considered an express warranty by The A.C. Houston Lumber Company for trusses we designed and manufactured for the above -referenced project. This warranty shall supercede all other warranties whether expressed or 0 implied, written or verbal. Warranties: The A.C. Houston I Lumber Company herein warrants for a period of ONE YEAR from the date of delivery referenced above, that the manufactured trusses shall be of fair and average quality in the trade and within the description of the contract and the project's documents as produced by the registered professional engineer for the project, hereinafter referred to as the "Engineer -of -Record". This warranty is for truss design and manufacturing only and specifically excludes installation and damage to the trusses when the trusses are out of our immediate control. This, warranty also specifically excludes work performed by the Engineer -of -Record including, but not limited to, structural design of the structure, structural drawings and construction design documents. Upon written notice, The A.C. Houston Lumber Company herein reserves the right to inspect, repair, or replace trusses that are not in conformity to contract documents, the Engineer -of -Record's project documents, improperly designed, or defectively �! manufactured trusses. All remedies and damages are strictly limited to repair or replacement of the non -conforming truss or trusses. Such replacement or repair necessity shall be determined at the sole discretion of The A.C. Houston Lumber Company. Replacement or -repairs shall be performed within a reasonable period of time and The A.C. Houston Lumber Company shall not be responsible for project delay damages or repair and replacement of other trades' work. This warranty shall be considered void if the truss or integral truss structure is affected by adverse influences including, but not limited to, moisture, temperature, corrosive chemicals, gases, cuts, damage caused by or contributed to by another trade, improper installation, improper or insubstantial bracing, improper field storage and handling, or additional dead or live loads beyond that stated in the truss engineering attributable to: roof, floor, partitions, mechanical, fire sprinkler systems, attic, storage, wind, snow drift, seismic or other acts of nature. The foregoing warranties are exclusive, and are in lieu of all other warranties, whether written, oral, or implied, including any warranties �. regarding the merchantability and fitness for a particular purpose not specified herein. Revised 02-03