Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RER (08-0185)
P.O-. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 080000185 Property Address: 4' 9760 MISSIONDR W APN: 649 -490 -024 -- Application description: REMODEL - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 14848 Applicant: Tiht 4 4 " BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Architect or Engineer: din ----------------=--------------------------------- LICENSED CONTRACTOR'S DECLARATION " I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division'3 of the Business and Professionals Code, and my License is in full force and effect. License Class* _-B_-- ..rA License No.: 792381 Datta. Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by ' any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the - improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or, improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. , BAP.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPER1t1IT Owner: QUINN JAMES M 49-760 MISSION DR. W. LA QUINTA, CA 92253 Contractor: RISEN CONSTRUCTION 82775.CHARLESTOWN A INDIO, CA 92201 (760)347-6399 Lic. No.: 792381 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/14/08 ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ' I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit,is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 229-0025305 certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. `Applicant:l�i�z�d ` -aFP . _ Dat WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND. DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions.and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and -for whose benefit work is performed under or pursuant to any permit issued as a result of this application, 'the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City _ of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject ' permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to buVconstrtion, and hereby authorize representatives of this county to rater upon the above-mentioned propepurpos s. ,, Date: Signature (Applicant or, Agent): LQPER1IIT Application Number . . . 08-00000185 Permit . . . BUILDING"PERMIT Additional desc . Permit Fee 162.'00 Plan Check Fee 105.30 Issue Date Valuation 14848 Expiration Date 11/10/08. Qty Unit Charge Per Extension BASE FEE 45.00 13.00 9.0000 THOU BLDG 2,001-25,000 ----------------------------------------- 117.00 Permit ELECT - ADD/ALT/REM Additional.desc . Permit Fee . . . . 23.37 Plan Check Fee 5.84 Issue Date . . . . Valuation . . . . 0 Expiration Date" 11/10/08 Qty Unit Charge Per Extension BASE FEE 15.00 143.00 .0350 ELEC'NEW RES - 1 OR 2 FAMILY _ 5.01 168.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 3.36 Permit... . MECHANICAL Additional desc . Permit..Fee . . . . 24.00 Plan Check Fee 6.00• Issue Date . . . . Valuation . . 0 Expiration Date 11/10/08 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH APPL REP/ALT/ADD 9.00 ---------------------------------------------------------------------------- Special'Notes and Comments CONVERT THIRD CAR GARAGE TO OFFICE"AND EXTEND EXISTING GARAGE 168 SQ. FT. Other Fees ENERGY REVIEW FEE 10.53 STRONG MOTION (SMI) - RES 1.48 Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total 209.37 .00 ---------- .00 209.37 Plan Check Total 117.14 .00 .00 117.14 Other Fee Total" 12.01 .00 .00 12.01 Grand Total 338.52 .00 00 338.52 t- Bin # City of La Quints Building & Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253- (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address:_ Q �. Owner's Name: A. P. Number: 602 �D-4 Address:49— 766 Misstirmi Dy- a_4e Legal Description: Contractor: S G Address: _ City, ST, Zip: 44 Telephone: ' 40 S164— (, Project Description: City, ST, Zip: z 7— ZU Telephone �� 42_ 63 $1' s 'l State Lic. # City Lic. #: lor Arch., Engr. esigne a S[ Address: • 61 6--- % A,A. Acol City, ST, Zip: CA Z 30 Telephone: 4©Q ' onsruconype: Q hcy:70Sa_ State Lic. #: Project type (circle o� N[w, d 'n Alter Repair Demo Name of Contact Person: S, q. Ft.: [Estimated # Stories: #Units: Telephone # of Contact Person:&&)) %�(J � Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING . PERMIT FEES Plan Sets Plan Check submitted 0 Item Amount �j Structural Calcs. Reviewed, ready f corrections fig' Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Cales. Plans picked up () p Construction Flood plain plan Plans resubmitted % if0 Mechanical Grading plan 2"d Review, ready or correctionsriss Electrical Subcontactor List Called Contact P on Plumbing Grant Deed Plans picked no a/4 7 S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- ''d Review, ready for correctio !issue Developer Impact Fee Planning Approval Called Contact Person y A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees Xf C 2-17lo� li� Pfn�n�, rLI� CERTIFICATE OF COMPLIANCE, �1FtEDs�,, Desert Sands Unified School District 47950 Dune Palms Road } ¢ BERMUDA DUNES ti " ' ' Cn RANCHO MIRAGE Date 5/14/08 d La Quinta, CA 92253 N INDIAN WELLS No: 30035(766).771-8515 : cy� P LA QUINTA .y (760) 771-8515QINDIO y7 . o Owner Quinn APN # 620-150-024 Address 49760 Mission Dr W Jurisdiction La Quinta City La Quinta Zip 92253 Permit # , Tract # No. of Units • ,1 Type Residential Addition Lot # No. Street S.F. Lot # No. _ Street S.F. Unit 1 49760 Mission Dr W 143 Unit 6 w Unit 2 Unit ? Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments , At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less , EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 143 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt Lucy Ruelas Check No. Name on the check Telephone 347.6399 ` , + Funding Exempt By Dr. Sharon P. McGehee �tt 6rR:r qy. M Superintendent Fee collected /exemp y S r n C rey Payment Recd O` ver/Unaeer 7 Signatures { NOTICE: Pursuant to Government Code Section 66020(d)(1), is w I serve to notify you that the 90-day approval period in which you may protest the fees o r other payment identified above will begin to run from the date o ich the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier: NOTICE: This Document NOT VALID without embossed seal - Embossed Original- Building Department Applicant Copy - Applicant/Receipt Copy - Accounting TITLE 24 REPORT Title 24 Report for: Quinn 438 s.f. Guest House - 49-760 Mission Drive West La Quinta , CA r Project Designer: Paul Nelson / 760.508.3400 Report Prepared By: 1, i David Elliott Energy Services 9013 SVL BOX VICTORVILLE, CA 9239 CITY OF j (760) 243-3883 LA QUI EP7 T. . BUILDING & S DEPT. Fo TION Job Number: 8-03-050 0 2008 Date: 3/12/2008 By The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California EnergyCommission for use with both the Residential and Nonresidential 2005 Building'Energy, Efficiency Standards. This program developed by EnergySoft, LLC.- www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number. 8-03-050 User Number: 1887 ' • • , ' - •� 1. - . Certificate Of Compliance :Residential 1 (Part 1 of 4) ' CFA R Vent Volume Units Zone Type Type a 3Rn. 1 nn Conditioned SpfhaCk Hgt. Area n Quinn 438 s f Guest Hal se 3/12/2008 Project Title Date 49-76011dission Drive West I a!llllnta Project Address * Building Permit # David Flliott Fner-0y Services (760) 243-3883 Documentation Author Telephone Plancheck/Date FneravPro15 Compli ceMethod ---._ _. Climate Zone Field ChecklDate TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 2.49 2.97 - -0.47 . . Space Cooling 97.92 .98.57 --0.65 , Fans 14.05 .15.96 =1.91 Domestic Hot Water 35.36 31.30: 4.06 Pumps 0.00 0.00 '0.00 ' Totals 149.82 148.80 1.02 y ' Percent better than Standard: 0.7% Building Type: �j Single Family ❑ Addition Total Conditioned Floor Area: 438 ft2 ❑ Multi Family Q Existing + Add/Alt Existing Floor Area: 0 ft2 Building Front Orientation: JSW).228 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Stab on Grade Area: 438 ft2 Fenestration: Area: 111ft2 Avg. U. Ratio: 25.3% Avg. SHGC: BUILDING ZONE INFORMATION Zone Name Floor Area Guest Nouse HVAC Average Ceiling Height: 10.0 ft. 0.39., Number of Dwelling Units: 1.00 0.37 Number of Stories: 1 # of Thermostat Vent Volume Units Zone Type Type a 3Rn. 1 nn Conditioned SpfhaCk Hgt. Area n -2 OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Rnnf Wnod 438 n MR R_314 R -n n n n Wall- - Wood _i i o -nim - lq_13 R -o -o _22s _qn Wall Wood 370 /+ 0102 RR-13 R - n c n off 11 3s Wall Wood 95 .'nm —R11 - _ R -n x)._3\2 Wall Wood 334 n_in? R-13 R-00 13590 Gains Condition Y / N Status JA IV Reference Location / Comments ►�, ■ �1:�� "wry ►A, OIL, i� Run Initiation Torre: 03/12/08 14:45:53 Run Code: 1205361953 . EnergyPro 4.3 by EnergySoR User Number. 1887 Job Number.. 8434M Page:2 d!8 Certificate Of Compliance: Residential (Part 2 of 4) CFJ R Quinn 438 s.f. Guest House 3112/2008 Project Title Date FENESTRATION SURFACES 1. Indicate source either from. NFRC or Table 11 6X 2: Indicate source either from NFRC or Table. 116B. INTERIOR AND EXTERIOR SHADING True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments Window Frets ($1LIL) 79-8 0 NEBG NFRC X25_-90- New Miloard Classic nr rn_F VinyJ Guest House 2 Window Rear (NE) 45.0 0.390 NFRC 0_37 NFRC 45 90 New Mitgard Classic Low -E Vinyl Guest House 3 Window Right (SE) 6.0 0.390 NFRC 0_37 NFRC 135 90 New Milprd Classic Low -E Vinyl Guest House 4 Window Right (SE) 29.8 0.390 NFRC 0_37 NFRC 135 90 New Milgard Classic Low -E Vinyl Guest House Run Initiation Time: 03/12/08 14:45:53 Run Code: 1205361953 Energy?re 4.3 by EnergySefl User Number. 18-A7 Job Number: 8 Pa^ -3 of 8 1. Indicate source either from. NFRC or Table 11 6X 2: Indicate source either from NFRC or Table. 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fn Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 6.5 5.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 7.5 6.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 6.5 5.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 6.5 5.0 2.0 0"1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 102 None No Insulation 26-81 New Guest House Run Initiation Time: 03/12/08 14:45:53 Run Code: 1205361953 Energy?re 4.3 by EnergySefl User Number. 18-A7 Job Number: 8 Pa^ -3 of 8 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R Quinn 438 s.f. Guest House 3/12/2008 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Guest House HVAC Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooring Location R Value Status Tested? Guest House HVAC Ducted Ducted Attic 8.0 New Yes Hydronic Piping pipe Pipe lnsul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (BhAr) (gal) Status or RE Loss (%) Ext. Standard Gas 50 gal or Less. Small Gas No Pipe Insulation 1 40,000 50 New 0.62 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Pipin Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS Roof: R-38 / Wall: R-13 / Window -39 Uf -.37 SHGC AU: 80% AFUE / A.C.: 13 SEER / Ducts: R-8.0 ERS Duct Test - TXV valve check - High EER Check COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Idle 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to Implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using dud design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater.. Designer or Owner (per Business 8 Professions Code) Name: Title/Finn: Paul Nelson / 760.508.3400 Address: le Lic. : 2 - (signature) (date) Enforcement Agency Name: TitletFirm: Address: Telephone: T xIm 11 C CalfpxnfaAssodatfon of Building Energy Consultants CBE0FlED"-ENERGY ANALYSE' �j ��DlAVID A. ELLIOTT (signature) (date) " a 1 — . . f Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R Quinn 438 s.f. Guest House 3/12/2008 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field HERS Required Verification Items in this section require field testing andfor verification by a certified home energy rater under the supervision of a CEC- mrrlw— — PIUVIYCI ub11111 VGV appluvCu LWbU11JJ a11u/01 vC1111U4L1Un metnous anu must oe rept)rteo on me ar-%K installation certificate Plan Field The HVAC System "Guest House HVAC" incorporates HERS verified'Duct Leakage: Target leakage is calculated and documented on the CF -4R - The HVAC System "Guest House HVAC" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "Lennox 12AC6-036" includes credit for a 11.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. EnergyPro 4.3 by ErtergySofl I User Number. 1887 Job Number. 8-03-050 Pam 5 of 8 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowhse residentiafbuildings subject to the Standards mustoontainthese'measures'regardless ofthe compliance approach used. ;More stringent compliance requiremerits from the Certificate of Compliance supercede the ftems marked with an asterisk (*),below. 'When this checldist'!Wincorporatediinto the permit documents, the features noted shallibe considered by all parties as minimum component performance specifications forthe mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. NIA DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑X ❑ 1. Masonry and factory -built fireplaces have: - ❑ ❑X ❑ § 150(a): Minimum R -191n wood ceiling insulation or equivalent U-factorin metaGrrame ceiling. ❑ N ❑ § 150(b): Loose fill insulation manufacturers labeled R -Value:. ❑ ❑X ❑ § 150(c): Minimum R-13 wallinsulation in wood framed walls or equivalent U41actor in metal frame walls (does not ❑ ❑X ❑ apply to exteriormass walls). ❑ ❑ ❑ § 150(4): Minimum 'R-13,raised.floor insulation in framed�floors or equWlent'U-factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs:.' ❑ ❑X ❑ 1. Masonry and factory -built fireplaces have: - ❑ ❑X ❑ a. closable metaDor glass door covering the entire opening or the firebox. ❑ ❑ ❑ b. outside air intake with damper and control; flue damper and' control ❑ ❑ ❑ 2. No continuous'buming gas;pilot1ights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §I 51 meets:requirements specified in the ACM Residential',Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(h: Slab edge insulation- water absorptionratefortheinsulationalonewithoutfacingsnogreatertham0:3%;watervapor ❑ ❑ ❑ permeance rate no greater than2:0'pemr/inctE ❑ ❑X ❑ § 118: Insulation specified or:installed,meets:insulation:installationquality standards. Indicate.type and,include ❑ ❑ ❑ CF -6R .Form: ❑ ❑ ❑ § 116-17: Fenestration'Products,'Ekteriorpoors, and lnfittration/Exfiftrafion'Contmis. 1. Doors and windows between. conditioned and unconditioned spaces designed to limit air leakage:. ❑ ❑X ❑ 2. Fenestration products (except field'fiabricated)e have label'withcertified; Um -Factor, certified. Solar Heat Gain, ❑ ❑ ❑ Coefficient (SHGC); and'infiltrationcertification: 1 ❑ ❑X ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations -caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified! by the Energy Commission:. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated 'inaccordance wfth ASHRAE, SMACNA'or ACOA.. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable;heating and/or cooling systems. ❑ ❑X ❑ § 1506): Water system pipe and tankInsulation and cooling systems iine'insulation. 1. Storage gas water heaters rated,withi an, Energy Factor; less than, 0:58. must be extemally.wrapped,with.insulation, ❑ ❑ ❑ having an installed thermal, resistance of R -12 -or greater.. 2. Baric -up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external' ❑ ❑ ❑ insulation or R-16 intemal'.insulabomand indicated'on:the exterior of the tank showing the R -value. 3. The following; piping,isiinsulated according to Table 150 -AB or -Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold waterpipes closest to water -heater tank non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of h6t water:pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping, insulated. between, heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-8 and Equation, 1 50-A. 4. Steam, hydronic heating systems or hot water systems > 15 psi; meet requirements of Table 123=A.. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that d'ue to sunlight; moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water;piping and refrigerant suction;piping includesa vapor retardant oris enclosed ❑ ❑ entirely in,conditioned space. 7. Solar water -heating systemstcollectors are certifiedby, the Solar Rating and Ceitification,Corporation. _ ❑ ❑ ❑ EnergyPro 4.3 by EnergySott User Number. 1887 Job Number 8-03-M Page:6 of 8 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below.. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N//! if not ENFORCE-1 applicable. NfA DESIGNER MENT Space Conditioning, Water ideating and Plumbing System Measures: (continued) § 150(m): Duds and Fans 1. All duds and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602,15M, 604, ❑ X❑ ❑ 605, and Standard 6.5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-42 or enclosed entirety in conditioned space. Openings shall be sealed with mastic, tape or other ductctosum system that meets the applicable requirements of UL 181, UL 181A, or UL 1818 or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑X❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. ❑ sealed sheet metal, dud board or flexible duct shall not be used for conveying conditioned air. Building cavities and a. At least 36' of pipe between filter and heater for future solar heating. ❑ ❑ ❑ support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ reductions in the cross-sectional area of the ducts. ❑ © ❑ burning pilot light. (Exception: Non-elechical cooking appliances with pilot < 150 Btw%r) 3. Joints and seams of dud systems and their components shall not be sealed with doth back rubber adhesive ❑ ® ❑ dud tapes unless such tape is used in combination with mastic and draw bands: ❑ ❑X ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are 4. Exhaust fan systems have back draft or automatic dampers. ❑ a] ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. 6. Protection of Insulation. Insulation shall be protected from damage,. including that, due to sunlight, moisture, equipment ❑ © ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water ❑ X❑ ❑ controlled by an occupant sensor that complies with Section 11 9(d) that does not tum on automatically or have an retardant and provides shielding from solar radiation that can cause degradation of the material. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover QC) and are ❑ X❑ ❑ 7. Flexible duds cannot have porous inner cores. ❑ Fx] ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, onaff switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36' of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ © ❑ burning pilot light. (Exception: Non-elechical cooking appliances with pilot < 150 Btw%r) § 118 ®r : Cool Roof material meets specified kriteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑X ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no'less than 20 kHz. § 150(k)l: HIGH EFFICACYLUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-0, ❑ Q ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ Q ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 1190. § 150(1)4: Permanently installed luminaires located other than in kichens bathrooms, ggarages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are co fled by a dimmer switch OR are ❑ X❑ ❑ controlled by an occupant sensor that complies with Section 11 9(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover QC) and are ❑ X❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ X❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for paridng tots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 1887 Job Number. 8403-050 Page:7 of 8 SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME . - - ` 1 DATE - - Quinn 438 s.f. Guest House 40,000 3/12/2008 SYSTEM NAME ' v Output (Btuh/sgft) FLOOR AREA Guest House HVAC. Output per System F 8 ENGINEERING CHECKS SYSTEM LOAD ' Total Output (Tons) 3.0 Total Output (Btuh/sgft) 81.3 Total Output (sgft/Ton) 147.6 Air System CFM per System ' 830 Airflow (cfm) 830 Number of Systems COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 1 Heating System Output per System 40,000 Total Output (Btuh) 40,000 Output (Btuh/sgft) 91.3 Cooling System Output per System F 35,600 Total Output (Btuh) 35,600 Total Output (Tons) 3.0 Total Output (Btuh/sgft) 81.3 Total Output (sgft/Ton) 147.6 Air System CFM per System ' 830 Airflow (cfm) 830 Airflow (cfm/sgft) 1.89 Airflow (cfm/Ton) 279:8 Outside Air (%) _ 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions JEATING SYSTEM PSYCHROMETRICS 26.0 OF 69.1 OF 69.1 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts 319 10,35 1 243 11,248 0 982 805 0 0 a 0 oil 0 0 0 , _ 0 982 805 TOTAL SYSTEM LOAD 12 31 1205 12 858 HVAC EQUIPMENT SELECTION Lennox 12ACB-036 28,924 0 40,000 Total Adjusted System Output 28.924 0 40,000 (Adjusted for Peak Design. Conditions): TIME OF SYSTEM PEAK Aug 2 m Jan 12 am 114.40F Outside Air LJ —, Supply Air Ducts 0 cfm l� Supply Fan Heating Coil 113.5 OF 830 cfm ROOMS 69.1 F °. _ 70.0 OF Retum Air Ducts ' )OLING SYSTEM PSYCHROMETRICS(Airstream Temperatures at Time of Cooling Peak 11.0/77.6°F 79.1 /59.0°F .01 Outside Air 0 cfm 79.1 i59.0 °F EnergyPro 4.3 by EnergySoft 79.1 / 59.0 OF 46.4/44.8 °F . Supply Air Ducts Supply Fan Cooling Coil 47.5 / 45.3 of 630 cfm 30.2% R.H. ROOMS 78.0/58.6°F Retum Air Ducts User Number: 1887 Job Number: 8-03-M Page:8 of 8