Loading...
RER (11-0324)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 b Application Number: 11-00000324 Property Address: 79010 MISSION DR W APN: 649-460-001- - Application description: REMODEL - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 16000 Applicant: T4'it " BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Architect or Engineer: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the B siness and Profession !s Code, and my License is in full force and effect. License Cla : _ License No.: 820801 ate: C ractor: �µN 0 R -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a peimit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of hot more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or.herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 ) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY - I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT Owner: SCHOOLEY OTIS B III & SUSAN C 78795 SPYGLASS HILL DR LA QUINTA, CA 92253 (714)322-2466 Contractor: D SANTUCCI BUILDERS INC 72529 BEAVERTAIL STREET PALM DESERT, CA 92260 (760)578-7757 Lic. No.: 820801 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/03/11 -ii MAY 0 4 2011 D WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I houId become subject the workers' compensation provisions of Section ///-/-137' ��00 of the Labor ode, I shalt forthw'[h comply with those provisions. at -e ! plicant: (�t��` WARNING: FAILURE TO SECURE ORKERS' MPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. - APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to ilding construction, and hereby authorize representatives of this coun to ter upon the above-mentioned prop rty for inspection p oses. Pde: 11 Si cure (Applicant or"Agent): c Application Number . . . . 11-00000324 ------ Structure Information 162SF TRELLIS W/ PATIO DOOR REMODEL ----- Other struct info . . . . . CODE EDITION ---------------------------------------------------------------------------- 2010 Permit . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 171.00 Plan Check Fee 111.15 Issue Date . . . . Valuation . . . . 16000 Expiration Date 10/30/11 Qty Unit Charge Per Extension BASE FEE 45.00 14.00 9.0000 THOU BLDG 2,001-25,000 126.00 ----------------------------------------------------------------------------- Special Notes and Comments 162SF TRELLIS PATIO WITH FRENCH DOOR ALTERATION AT CASITA [ENGINEERED] 2010 CALIFORNIA BUILDING CODES. May 2, 2011 5,:12:47 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . ... . BLDG STDS ADMIN (SB1473) 1.00 STRONG MOTION (SMI) - RES 1.60 Fee summary Charged Paid Credited ---=------------------------------------ Due ----------------- Permit Fee Total 171.00 .00 .00 171.00 Plan Check Total 111.15 .00 .00 111.15 Other Fee Total 2.60 .00 .00 2.60 Grand Total 284.75 .00 .00 284.75 LQPERMIT Mar 3U 11 U3:U3p KANUHU LAUUIN IA HVA rovI I lotto i . N. i RANCHO L& QUI' Aksm Assocr. noN Architectural Control Committee. February 14,,2011 Mr. and Mrs. Otis Schooley 79-010 Mission -Drive West La Qu€nta, CA 92253 Re: 79-010 Mission Drive West Approval of Submission The Ard'titectural Committee reviewed your submission for removal of existing Pool/Spa and landscape and addition of a Pool/Spa, hardscape, BarM Fire Pit and landscape. Additionally, the addition of a new front door; the submission as presented is approved upon cendrtioa oF. The Committee requires the following: • All work is to be done in accordance with alliapp icable requirements of governmental entities, including the City of La Quirita and in accordance with all Homeowners Association architectural guidelines and gavern€ng documents. • if applicable, a. City of La Quinta building permit be obtained a nd.copy furnished to the Association prior to corhmencement of wont. • No access from the Golf Course may be used Dumosters are is be Qiaced in driveway — not in the street. When the work has been finished, please return "Notice of Completion" to the Association Office. The Association's architectural consultant will perform a final inspection after receipt of such notice; when verification of the approved pian modifications have been.concluded, your Security Deposit will be processed for refund.' Thanking you in advance. and if any questions please do not hesitate to call me at the onsite office 777.8807. Since , CCAAAO Associalim'Ceteral Manager. 760-77-8807 fax 760-777-8961 mwalkert9dnjntemeicom cc: Architectural.Comm.- P.O. BOX; 6419 • L QUIlhTIA, CA 92248-6419 . 760-777-8807 FAX 76OL-777-8961 ,77 . . . . . . A R. UttVtLU ItR::5'-K DOORS tiT r. ilf . . . . . . . .... ...... ... ..... ... REE--� P L rz A is�l AQ urtr » r' City of La Quinta Building & Safety Division Permit # P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Project Address: W0 lhlfJ soh O %'• W . Owner's Name: (%8 and fbP .Schap/e A. P. Number: tP 02 — /t/0 -00/ 7go1d Address: /Jf/ah Oi•. (y, Legal Description: ,3V !�c /+i/c a, Cat39/�16 273 a3 city, ST, Zip: Cq 47 'M Ci} 972.T3 Contractor: Je/'r .T�`lfvC� L Telephone: %/S/ 322 2 y�CO Address: Project Descriptiioon lie�ryj�C/`p / eXa% City, ST, Zip: Telephone: 76 D S 7F 7 719 7 D i do !-1 X / Gv 8 9 0 o r f State Lic. # : City Lic. Arch., Engr., Designer:Uove Address: %a' FP City, ST, Zip: PQM* Owef-t CR 9Z z CpQ Telephone: 76d 3 6 7 3 Y f .0 Sta to Lic. #• C 3 Construction stru cti on Type: Y P: Occupancy: P Y� I2 1 Name of Contact Person: teJ Project c t rc le type �c► one): New Add'n Alte Repair Demo Sy UP eSq. Ft.: # Stories: # Units: Telephone # of Contact Person: 7ba 3� 7 3.T Estimated Value /l0 OQ. of Project: lb 00 .,L '1VO %A - APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING Plan Sets Plan Check submitted 1 PERMIT FEES Item Structural Cates. Reviewed, ready for corrections 111 Plan Amount Check Deposit Tress Calcs. Called Contact Person li 111 Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted �/� (�" Mechanical .� Grading plan tad Review, ready for corrections Electrical ^ Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. I bd H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Jrd Review, ready for correctionslissue Developer Impact Fee Planning Approval Called Contact Person I.P.P. Pub. Wks. APer Date of permit issue VA—V— School Fees • Total Permit Fees 1 4114 uil • �S`S'ItL � �D c�wasyfi .� 1 I.. BUILDING ENERGY ANALYSIS REPORT I PROJECT: °Schyo6le�iCa�ita 79010 Mission Drive West La Quinta, CA Project Designer: Curtis R. Shupe, Architect. 72880 Fred Waring. Drive Suite A-5 Palm Desert, CA 92260-9374 Abhor t� "Prepawed by: Joan D. Hacker Insu-form, Inc. 77-810 Las Montanas Road, Suite 201 Palm Desert, Ca 92211 760-345-1352 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED Job,Ntrbeir FOR CONSTRUCTION DATE 8Y -Date: 4/19/2011 1D' _ IJ 1 APR 2 0 2011 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC —www.energysoft.com. us/yev TABLE OF CONTENTS l Cover Page Table of Contents Form CF -1 R Certificate of:Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary EnergyPro 5.1 by EnergySoR Job Number ID: User Number. 2655 1.. 2 3 8 11 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Schooley Casita Building Type ® Single Family ❑ Addition Alone O Multi Family ® Existing+ Addition/Alteration 1411912011 Date Project Address 79010 Mission Drive West La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 417 Addition 0 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ® No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes EI No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status Wall Wood Framed R-13 1,100 Existing Door Opaque Door None 21 Existing Roof Wood Framed Attic R-19 417 Existing Slab Unheated Slab-on-Grade None 417 Perim =15' Existing FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Front (SW) 20.0 0.400 0.36 2.0 none Bug Screen Existing Front (SW) 11.0 0.400 0.36 2.0 none Bug Screen Existing Rear (NE) 30.0 0.400 0.36 2.0 none Bug Screen Existing Right (SE) 48.0 0.500 0.40 8.0 none Bug Screen New Right (SE) 6.0 0.400 0.36 8.0 none Bug Screen Existing Right (SE) 16.0 0.400 0.36 26 none Bug Screen Existing Right (SE) 8.0 0.400 0.36 2.0 none Bug Screen Existing HVAC SYSTEMS Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 8.00 HSPF Split Heat Pump 13.0 SEER Setback Existing HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status Casita Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER. HEATING Type Gallons Min. Eff Distribution Status EnergYPrO 5.1 bY Ener Soft User Number. 2655 MmCode: 2011-04-19T14:01:57 ID: Page 3 of 11 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1R Project Name Schooley Caslfa Building Type ® Single Family . ❑ Addition Alone ❑ Mufti Family ® Existing+ Addition/Alteration, Date 4/19/20.11 SPECIAL `FEATURES INSPECTION -CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items. require special written. justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the si3ecial justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. EnemyPro 5.1 by EnemySoff User Number. 2655 RunCode: 2011.04-19714:01:57 ID: e 4 of 11 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type ® Single Family ❑ Addition Alone Date Schooley Casita ❑ Muni Family m Existing+ Addition/Alteration 4/19/2011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/fi2- Space Heating 13.54 14.25 -0.71 Space Cooling 194.95 194.39 0.55 Fans 42.47 42.20 0.27 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 250.95 250.84 0.11 Percent Better Than Standard: 0.0% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (Svt7 225 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (Stn9 260 31 Fuel Available at Site: Natural Gas (W 400 0 Raised Floor Area: 0 (NE) 200 30 Slab on Grade Area: 417 (SE) 400 78 Average Ceiling Height: 10.0 Roof 417 0 Fenestration Average LI -Factor: 0.43 TOTAL: 139 Average SHGC: 0.37 Fenestration/CFA Ratio: 33.3 REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Insu-form, Inc. N 411912011 Address 77-810 Las Montanas Road, Suite 201 Name Joan D. Hacker C'/State/ZipChy/State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 Si ed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verffication of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Curtis R. Shupe, Architect Address 72880 Fred Waring Drive Name �0-4 133 �� Suite A-5 City/StateRpalm Desert, CA 92260-9374 Phone Signed License# Date i EnemvPfo 5.1 bv EnerovSoft User Number: 2655 Rundode. 201140419714:01:57 ID: Pae 5 of 11 ,CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5). CF -1 R Project Name Schooley Casita Building Type O Single Family ❑ Addition Alone ❑ Mufti Family ® Existing+ Addition/Afteration Date 4/19/2011 OPAQUE SURFACE DETAILS Surface. U- Insulation Joint Appendix Type Area Factor I Cavity Exterior Frame I Interior Frame Azm Tift Status 4 Location/Comments Wall 229 0.102 R-13 225 90 Existing 4.3.1-A3 Casita Wall 400 0.102 R-13 315 90 Existing 4.3.1-A3 Casita Wall 170 0.102 R-13 45 90 Existing 4.3. i -A3 Casita wall. .30.1.1 0,102, R-13 135.. 19.01 Existing.. 4.3.1 -Al Casita., Door 21 0.500 None 1351 90 Existin 4.5.1-A4 Casita Roof 417 0.049 R-19 2251 0 Existin 4.2.1-A4 Casita Slab 417 0.730 None 01 180 1 Existing 4.4.7-A1 Casita FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 - Window 20.0 0400 `NFRC "0:36' NFRC 225 'Fxisting Double Metal Casita 2 Window 11.0 0.400 NFRC 0.36 NFRC 225 Existing Double Metal Casita 3 Window 30.0 0.400 NFRC 0.36 NFRC 45 Existing Double Metal Casita 4 Window 48.0 0.500 NFRC 0.40 NFRC 135 New French Doors Casita 5 Window., 6.0 0.400 NFRC 0.36 NFRC 1351 Existing Double Metal Casita 6 Window 16.0 0.400 NFRC ' 0.36 NFRC 135 Existing D u le Metal -Casita 7 Window 8.0 0.400 NFRC 0.36 NFRC 135 Existing Double Metal Casita 8 Window 24.0 0.550 NFRC 0.55 NFRC 135 Removed Double Non Metal Clear Casita (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC T 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hot I Wd ove ana Left -Fin Len Hot I LEM RExt Dist I Len Hgt Ri ht Fin Dist Len Hot 1 Bug Screen 0.76 4.0 5.0 2.0 0.11 2.0 2.0 2 Bug Screen 0.76 2.5 5.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 6.0 5.0 2.0 0.1 2.0 2.0 4 Bug Screen 076 8.0 6.0 6.0 01 8.0 a.0 5 Bug Screen 0.76 2.0 3.0 8.0 0.1 8.01 8.0 6 Bug Screen 0.76 4.01 4.0 2.0 0.1 2.01 2.0 7 Bug Screen 0.76 2.51 4.0 2.01 01 2.01 20 8 Bug Screen 0.76 8.01 3.0 2.0 0.1 2.01 2.0 EnergyFro 5.1 by EnergySoft User Number. 2655 RunCode: 2011-04.19714:01:57 /D: Page 6 of 11 .CERTIFICATE OF COMPLIANCE: Residential _(Part 5 of 5): CF -1 R Project Name Schooley Casita Building Type ® Single Family ❑ Addition Alone ❑ Mufti Family ® Existing+ Addition/Alteration Date 4/19/2011 BUILDING ZONE INFORMATION System Name Zone Name Floor, .Area New EAstina Altered Removed Volume Year Built Casita Casite 417 4,170 1996 Totals 0 417 0 0 "HVA -C SYSTEMS - S stem Name Cny. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Casita 1 Split Heat Pump 8 00 HSPF Split Heat Pump 13.0 SEER Setback Existing HVAC. DISTRIBUTION System Name Heating Duct Coolinq Duct Location R -Value Ducts Tested? Status Casits Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing 13 13 WATER HEATING SYSTEMS System Name T e Distribution Rated Input Btuh Tank Cap. al Energy Standby Factor Loss or or RE Pilot :Ext Tank Insul. R- Value . Status CEC Standard MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft � in Q. — System Name Pipe Length Pipe Diameter Insul. Thick. :TH Plenum Outside Buried 13 1 13 13 EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2011-04-19T14:01:57 1D: Pae 7 of 11 MANDATORY MEASURES SUMMARY: Residential .Pae 1 of 3), MF.I R Project Name Schooley Casita Date 4/19/2011 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the.Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- - '1`R-AL`VPorm)-sti i 1-tupersede ttie items-marked`whh-an-asfensk (`) befow:=iisfiifandatory-lAeasures`SbmmarystialFbe`'inwrporated- into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MFA R Form with plans, Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of § 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. *§l 50a : Minimum R-19 insulation in wood-frame ceiling or equivalent U-factor. 150(6. Loose filif insulation shall conform with manufacturer's installed desi�n labeled`R-VAIue. *§l 50c : Minimum R-13 insulation in wood-frame wall orequivalent U-factor. *§l 50d : Minimum R-13 insulation in raised wood-frame floor orequivalent U-factor. 150 Air.retardin wr is tested ,labeled and installed_accordin to ASTM.:E1677.95 2000 =when: ecified.onthe:CF�1 §150(g): Mandato V or barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or facto built fireplaces have a closable metal or alass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory-built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible operable, and tight-fitting damper and or a combustion-air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the .outside of the buildin ,,are prohibited, Space Conditioning, Water Heating and Plumbing stem Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release :-vafve baekfl©w= revention ° um isolation valve and recirculafion-Ioo ,connectionr - riirements�of 413 a 5`. §115: Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h; Heatin and/orcooli.. .loads,are,cak:ulated.in.accordancewithASHRAE.SMACNA,..or_ACCA,_a_._ 150 6- Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water-heating system, or other indirect hot water .:,,tanks,have,R-t.2_exterrtWl insulaUon:.or R.:6.inte.rnal;;insalatig-n where.:the..in_terna6;irrsulation:,R:valoe;is:indicated.;onahe=e)denor,of.;the. tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non-recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot waterAank:shall,.be..insulmedeto;Table-•150,B-and-E quat ion4W;-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 1.50.' 3A:.Insulation is. rotecte :from.dama a including that due to sunlight, moisture equipment maintenanceand wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned s ce. 150(')4: Solar water-heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPho 5.1 6y EnergySoft User Number. 2655 RunCode: 2091-04.19T14:0 4i ID: Page 8 of.11 ..MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3). MF -1 R Project Name Date Schooley Casita 1411912011 ,.§:1,50 jm)i: AU.air.-dicdnbutiomsysiem.,ducts.: ar4pleraumsilinstaUed,..are sealed„ancUnwWed to.:meet the.,requiremwts,of..CMC.Sections.. . 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 114 inch the combination of mastic and either mesh or tape shag be used :..§1.5D(m):1::..Building.:cavhies,.supp .rtplatforms,.for.,airhandle.rs,..and�plenums.defined.,or..constructed,,withimaterials.other,.than.sealed.. sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless.such.t :is.used,in:combination.whb.mastic.and,draw.bands... §150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. -Cellular foam•insulatidn shall=W-protected'as`above &pa MWt withla coating•thatis *atd�-retardantTand°provides siuetditV-fromsolar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSUASHRAE Standard 622-2007 Ventilation and Acceptable Indoor Air Quality.in Low -Rise Residential Buildings. Window operation is not a.permissible method of providin Whole Building Ventilation .the required in Section 4 of that Standard. Pool and Spa Heating stems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater, a permanent weatherproof plate or card with operating instructions; and ^shall not -use etecEric resistance #zeatin or °a ilot li §114(b)1: Any pool or spa heating equipment shall be installed with at least 36” of pipe between fitter and heater, or dedicated suction and return lines, or built-upconnections for future solar healing. 1(b)2: Outdoor pools ors as that have a heat um or as heater shall have a cover. §114(b)3: Pools shall have directional :inlets that adequately mix the..pool water, and a time switch that will allow all. pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems or equipment meet the pump sizing, flow ratepiping,filters and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy„ luminaires or LED Light Engine with Integral Heat Sink has an efficacythat is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150.(k)5: Permanently installed night lights and night bights integral to a.permanentlyinstalled luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). ` 1'S0 k W: Ail"smAtdhing devices and controls shall'meet"the requirements, of§150(k)7.- 1'50 k 7:§150(k)8: §150(k)8:A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 112 may be exempt from the 500/6 high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed -luminaries in garages; laundry rooms, closets greaterihan WO square"feet; and utility rooms are-highf efficacy and controlledby a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro.a 1.:6y,EnergySaft. User -Number. - 2655.. .,MmOade..291.1.04r.19T.14:4 :57- 1D: Rage -9,0711-1. MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3), MF-1 R Project Name pate Schooley Casita 14119)2011 _,§150(k)1O:. errnaraeratlyinstalled,luminaires.. bathruo; attached.�anddetactked.garages,_.laundry:rooms,...close.ts.:and..utility..cooms. shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a .manual,on..occ an :;sensor: §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual- on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less ...than t.OQO s ar.ef.6.Wocated.on,a.:residential,siie_is..notr, 'red to,cp _with..15A k 1.1. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. ..§.i5.0,(k.).13:.Lurnir aires..p viding.outdoor lighting,.including.,Dghtng._tor pr-ivate.{raiios,:in:.low-rise..iesidentiat buikhngs wiih_four.or..more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical..time.,clock not .having an.override-orbypass.switch.lhatdisables;,theastrono.mical.time.clock;.OR.an.e , y.management,. . control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the Califomia Electric Code need not be.,hi h,.efficac , luminaires.. §150(k)14: Intemally illuminated address signs shall comply with Section 148; OR not contain a screw-base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132,134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable ,requirementsof:.Sections..130.1.3.1.,339,and1A6... §150(k)16: Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EneigyRo 5.1 by EnergySoft User Number.- 2855 RunCode. 2011-04-19714:01:57 1D: Page 10 of 11 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Schooley Casita Date 4/19/2011 System Name Casita Floor Area 417 ENGINEERING CHECKS SYSTEM LOAD Number of Systems COIL CFM -' T'i3t8T:RO01ti°LOads- Return Vented Lighting Return Air Ducts Return Fan Ventilation' Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK Sensible .14,j4.18;., 0 968 01 0 0 410 968 13,765 COIL HTG. Latent CFM -813 371-• 0 0 813 PEAK Heating System Sensible ...: -20;800 . r 1.0;595 Total Output Stuh 20,800 output Stuh/ ft 49.9 575 Cooling m 0 Output per System 22,600- 0 Total Output Btuh 22,600 -410 Total Output ons 1.9 575 Total•O" Btu ..84:2 Total Output on 221.4 11,335 Air System CFM per SygLern 800 HVAC EQUIPMENT SELECTION Alrflow cfm 800 York 17,101 2,0681 12,991 Airflow cfm/ 1.92, Airflow cfmfron 424.8 -OutsideAlr % 0'0`"% `TOt81"A iusted'Syetem-'Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK -t7-,101: 2;068 Aug 3 PM ` 12;991' Outside Air cfm/ 0.00 I Note: values above glven at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heath Peak 26 OF Outside Air 0 cfm 69 OF 69 OF 97 OF 97 OF NO fns Heating Coil Supply Fan 800 cfm 97 °F ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 76 / 62 OF 76!62°F 55/54°F 55!54°F c Cooling Coil Supply n 800 ctrn � 47.2.."/0 57 ! 55 OF ROOM, 75 / 62 OF, I EnergyPro 5.1 by EnergySofi` User Number. 2655 RunCode: 2011-04-19T14:01:57 ID: Page 11 of 11