Loading...
AR (07-1575)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description Property Zoning: Application valuation: Applicant: �.6 C7-00001575 79036 MISSION DR W 649-460-003- - - ADDITION - RESIDENTIAL LOW DENSITY RESIDENTIAL 29493 Architect or Engineer: Vw BUILDING & SAFETY DEPARTMENT BUILDING PERMIT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B License No.: 646125 Date: I& 3o h.7 --,Contractor: � /Z '�' (40 OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who,does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to.construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractorls) licensed pursuant to the Contractors' State License Law.). - 1 _ 1 I am exempt under Sec. , BAP.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: — Lender's Address: LQPERMIT Owner: EDWARD C. LATEK 79-030 MISSION DRIVE WEST LA QUINTA, CA 92253 Contractor: KURTZ CONSTRUCTION INC 74935 FAIRWAY DRIVE PALM DESERT, CA 92260 (760)346-6932 Lic. No.: 646125 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 130/07 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 0440022284 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I phall forthwith comply with those provisions. . WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to buildingj construe on, an ere y amhoraae_re�sentatives of this county to enter upon the above-mentioned proper y 6r ins echo ur ses. Date: ')1-i0'Cy Sj nanattire.(Applicant,or.Ag tl: Application Number . . . . . 07-00001575 ----- Structure Information 365SF CASITA ADD/V-NR/R-3 [ENGINEERED) ----- Other struct info . . . . . CODE EDITION 2001/2005 # BEDROOMS 1.00 FLOOD ZONE NO ` 1ST FLOOR SQUARE FOOTAGE 365.00 ---------------------------------------------------------------------------- Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 284.5.0 Plan Check Fee 184.93 Issue Date . . . . Valuation 29493 Expiration Date 5/27/08 Qty Unit Charge Per Extension BASE FEE .252.00 5.00 6.5000 THOU BLDG 25,001-50,000 32.50 ----------------------------------------=----------------------------------- Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 27.78 Plan Check Fee 6.95 Issue Date . . . . Valuation . . . . 0 Expiration Date 5/27/08 Qty Unit Charge Per Extension BASE FEE 15.00 365.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 12.78 ---------------------------------------------------------------------------- Permit . . MECHANICAL Additional desc . Permit Fee 19.50 Plan Check Fee 4.88 Issue Date Valuation . . . . 0 Expiration Date 5/27/08 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 ---------------------------------------------------------------------------- Special Notes and Comments 365SF ADDITION TO CASITA/V-NR/RES-3 [ENGINEERED] THIS PERMIT DOES NOT INCLUDE BLOCKWALLS. ADDITION TO-CASITA ONLY. 2001 CBC, CMC,. 2005 ENERGY. November 29, 2007 7:45:38 AM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . ... . ENERGY REVIEW FEE 18.49 LQPERMIT LQPERMIT c Application Number . . . . . 07-00001575 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STRONG MOTION (SMI) - RES 2.94 Fee summary Charged Paid Credited Due ' Permit Fee Total 331.78 .00 .00 331.78 Plan Check Total 196.76 .00 .00 196.76 Other Fee Total 21.43 .00 .00 21.43 Grand Total 549.97 .00 .00 549.97 LQPERMIT Bin # City of La Quinta. Building U Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # % Project Address: `' — 030 0") . �2, ' Owner's Name: p E A. P. Number: Address. Legal Description: City, ST, Zip: J / A.) A fj Z 2- C3 Contractor: Telephone: Address: Project Description: C City, ST, Zip: I a 45 A) 7'i D A% 76, X o -0 , Telephone: State Lie. #: City Lic. #: ff M v p F L /5I z ,2,- D D Arch., Engr., Designer: Address: City, ST, Zip: Telephone: State Lic. #: Name of Contact Person: Q / Construction Type: Occupancy: Project type (circle one): New Add'n Alter. Repair Demo Sq. Ft.: # Stories: #Units: Telephone # of Contact Person: $7 Estimated Value of Project: LA7 K QP l ' 4L'A PP LICA&T: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACIMG PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person �I Plan Check Balance Energy Calcs. Plans picked up Construction Flood plain plan Plans. resubmitted Mechanical Grading. plan104 2'' Review, ready for correctio ssue Electrical Subcontactor List Called Contact PeronPlumbing Grant Deed Plans picked up S.M.I. R.O.A. Approval Plans resubmitted Grading IN ROUSE:- ''' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.LP.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees 6 u ?ods}. - Psl trTgVa ' FAY vo ��!E a G6��Y Date 11/30/07 No. 29798 Owner Edward Latek Address 79030 Mission Drive West City La Quinta Zip 92253 Tract # Type Residential Addition CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 APN # Jurisdiction Permit # Study Area No. of Units xFtSc�o Q BERMUDA DUNES r CAI RANCHO MIRAGE d J INDIAN WELLS PALM DESERT y LA QUINTA QINDIO y� O 649-460-003 La Quinta 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 79030 Mission Drive West 365 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less 1:04M21 This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 365 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Ken Kurtz Check No. Name on the check Telephone 250.5378 Funding Exempt By Dr. Doris Wilson Superintendent -, Fee collected /exemp d by Sh ro AM Gil ry Payment Recd *.00 iJ Signature `; � - 4 NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting TITLE 24 REPORT I Egd1aAd3 Title 24 Report for: Lat ek Residence 79-030 Mission Drive West La Quinta, CA Project Designer: Curtis 'R. Shupe.",,:' 72880 Fred 'Waring , Dr Ste `M5 Palm _ Desert;; cA .92260-9374. j' 4 Report Prepared By: Joan D. Hacker Insu-form, Inc. 41-921 Beacon Hill, Suite A Palm Desert, CA 92211 (760) 779-0657 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUC DAT'' BY Job Number: 0 Date: � �,pY 2 5 200 5/21/2007 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: User Number: 2655 ws TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary Room Load Summary 1 2 3 7 9 10 EnergyPro 4.3 by EnergySoft Job Number: User Number: 2655 Certificate Of Compliance: Residential Existing Floor Area: (Part 1 of 4) CF -1 R I atrek Residence Project Title 0 ft2 Slab on Grade Area: 782 ft2 sm /2no7 Date 79-030 Mossion Drive Project Address West I a Quinti 1.00 Number of Stories: Building Permit # Insu-form,_Inc_ (760) 779-0657 Documentatlon Author Telephone plan Check/Date FnergyPm Complia'irfce Method 15 Cllmate Zone Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 12.24 10.18 2.05 Space Cooling 214.68 212.75 1.93 Fans 29.16 28.82 0.34 Domestic Hot Water 21.74 25.30 -3.56 Pumps 0.00 0.00 0.00 Totals 277.82 277.05 0.76 Building Type: W Single Family ❑ Addition ❑ Multi Family [jo Existing + Add/Alt Building Front Orientation: (SE)135 deg Fuel Type: Natural Gas Fenestration: Area: 149 ft2 Avg. U: 0.75 Ratio: 19.1% Avg. SHGC: 0.70 BUILDING ZONE INFORMATION Zone Name Total Conditioned Floor Area: 782 ft2 Existing Floor Area: 417 ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 782 ft2 Average Ceiling Height: 8.5 ft Number of Dwelling Units: 1.00 Number of Stories: 1 # of Floor Area Volume Units Zone Tvoe OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall Wnnd QS n 089 R_91 R_n n _" F;gp Wall Wood 164 0 069 _ Q-21 R-0.0 315 90 Wall Wood 60 0 064 R-21 R-0.0 _ 45 9Q Rnnf Wnnd 365 _ n n95 R -3R R-0 n 135 _ n Wall Wood 156 0110 R_11 R-0.0 13S An Door None 40 0 500 None_ R-0.0 135 An Wall Wnpd 990 0110 _B_11 R -n 0 99r1-9fl Wall Wnod 360 0 110 R_1l R_0 0 315 An Wall Wood 160 0.110 R_11 R-0 0 _ 45 A0 Rnof Wood 9 137 0 051 _B-19 -nn X3.1; Thermostat Vent Type Hgt. Area Sethark _� n/a Gains Condition Y / N Status JA IV Reference Location / Comments EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:3 of 10 1 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Latrek Residence Project Title 5/21/2007 Date FENESTRATION SURFACES True Cond. # Type Area U -Factors SHGCZ Azm..Tilt Stat. Glazing Type Location/ Comments Window 1 aft _(,SW) 25 0 n 700 NFRC: 0 70 NFRC "$_ -M New Milgard Additinn •2 Window Rear (NW) 10.0 0.700 NFRC 0_70 NFRC 315 90 New Milgard Addition • 3 Window Rear (NW) 10.0 0.700 NFRC 0_70 NFRC 315 90 New Milgard Addition • 4 Window Right (NE) 10.0 0.700 NFRC 0_70 NFRC 45 90 New Milgard Addition • 5 Window Right (NE) 40.0 0.700 NFRC 0_70 NFRC 45 90 New Milgard Addition • 6 Window Right (NE) 10.0 0.700 NFRC 0.70 NFRC 45 90 New Milgard Addition • Z Window Front GSFI 444...000 0.879 NFBQ1LZ0 NFRC 135 -90 x' ting Double Mtl Uncoated Default Living one .8 Window Right (NE) ATT 0.870 NFRC 070 NFRC 45 90 Ebsting Double Mb Uncoated Default Living Zone _ 2.0 3 Bug Screen 0.76 5.0 2.0 2.0 0.1 2.0 2.0 4 Buq Screen 5 Buq Screen 6 Bug Screen 7 Bug Screen 8 Bug Screen 0.76 0.76 0.76 0.76 0.76 5.0 8 0 5.0 2.0 7.5 2.0 2.5 2.0 2.0 6.0 _ 2.0 ��1 2.0 2.0 -_ 2.0 0.1 2.0 2.0 _ 2.0 01 2.0 2.0 _ 2.0 0.1 2.0 2.0 _ 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation R -Val. Location Condition Location/ JA IV Reference Status Comments oiag renmeier its None NO Insulation 26-A1 New Addition Slab Perimeter 28 None No Insulation 26-A1 Existing Living Zone I EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:4 of 10 1 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Len. Hgt. LExt. Left Fin Right Fin RExt Dist. Len Hgt Dist Len Hgt 1 Bug Screen 0.76 5.0 5.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 5.0 2.0 2.0 0.1 2.0 _ 2.0 3 Bug Screen 0.76 5.0 2.0 2.0 0.1 2.0 2.0 4 Buq Screen 5 Buq Screen 6 Bug Screen 7 Bug Screen 8 Bug Screen 0.76 0.76 0.76 0.76 0.76 5.0 8 0 5.0 2.0 7.5 2.0 2.5 2.0 2.0 6.0 _ 2.0 ��1 2.0 2.0 -_ 2.0 0.1 2.0 2.0 _ 2.0 01 2.0 2.0 _ 2.0 0.1 2.0 2.0 _ 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation R -Val. Location Condition Location/ JA IV Reference Status Comments oiag renmeier its None NO Insulation 26-A1 New Addition Slab Perimeter 28 None No Insulation 26-A1 Existing Living Zone I EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:4 of 10 1 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R Latrek Residence 5/21/2007 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Living Zone Central Furnace 75% AFUE Split Air Conditioner 10.0 SEER Existing Setback HVAC DISTRIBUTION Duct Duct Condition Ducts • Location Heating Cooling Location R -Value Status Tested? Living Zone Ducted Ducted Attic 4.2 Existing No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Standard Gas 50 gal or Less Small Gas No Pipe Insulation 1 40,000 50 New 0.53 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sp.li^ r.—i— . hifi. Ma.. -nd field verification by an approved HERS rater. Designer or Owner Curtis R...Shupe Documentation Author Name: Architect Name: Joan D. Hacker Title/Firm: %2880 i'Ped Waring Dr. Ste A5 Title/Firm: Insu-form, Inc. Address: Palm, Desert, CA 92260-9374 Address: 41-921 Beacon Hill, Suite A Palm Desert, CA 92211 Telephone: 60 Wr—Lic.* 61219& Telephone: 17601.779-0657 S 7i v 7 ZI 0? (signatur (date) (signature) (date) Enforcement Agency Name: Title/Firm: Address: STAMP Telephone: (signature) (date) Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R Latrek Residence 5/2112007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the Items specified In this checklist These Items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the .ucyuacy v1 Ulu apcu1a1 juaunaauun anu uoaumencaaon suomima. Plan I Field The Existing Furnace " Usting" has an AFUE less than the Table R3-11 CEC Default Vintage Values. The Existing Roof "Roof' has a U -Factor greater than the Table R3-11 CEC Default Vintage Values. HERS Required Verification Items In this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- a.,.... —1 uooc .. alae �1.... rcr. , vl — M-- —1--l-48— rr•-•-- • •-•• r•..•.....• "•••••y Installation certificate. YY—1511 11 .11CU-0 anu 111YO1 uC 1CPLPFL CU V11 Ulu CF -4m Plan Fleld run maiatio I l e: ua/�7/ui uyartt Ku Lo e: 1 7976547 EnergyPro 4.3 by EnergySoft, User Number: 2655 Job Number: Page:6 of 10 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the hems marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere In the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA If not applicable and Included with the ENFORCE - permit application documentation. NIA DESIGNER MENT Building Envelope Measures § 150(a): Minimum R-19 Inwood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturers labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall Insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ Q ❑ apply to exterior mass walls). § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -bush fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ penneance rate no greater than 2.0 pemVinch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include El © El Form: § 116-17: Fenestration Products, Exterior Doors, and Infihration/ExFltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑ ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ❑ ❑ ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑ ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ § 150(1): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑x ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an Installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and Indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-8 and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including'that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:7 of 10 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance superoede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, r-1 El❑ 605, and Standard 6S; supply -air and retumair ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape Is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed In cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ❑ ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑ ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ ❑ ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is Installed with: a. At least 36' of pipe between finer and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (1): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ® ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ ❑ OR are controlled by an occupant sensor(s) certified to comply with Section 119(d). § 150(k)4: Permanent Installed luminaires located other than in kichens bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 It)) OR are controlled by dimmer OR ❑ ❑ ❑ a switch are controlled by an occupant sensor that complies with Section 11S(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming poolst water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). I.EnergyPro 4.3 by EnergySoft User Number. 2655 Job Number: Page:8 of 10 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Latrek Residence 5/21/2007 SYSTEM NAME FLOOR AREA Livina Zone 782 [ENGINEERING CHECKS IISYSTFM LOAD Number of Systems 1 Heating System Output per System 60,000 Total Output (Btuh) 60,000 Output (Btuh/sgft) 76.7 Cooling System Output per System 56,000 Total Output (Btuh) 56,000 Total Output (Tons) 4.7 Total Output (Btuh/sgft) 71.6 Total Output (sgft/Ton) 167.6 Air System CFM per System 2,210 Airflow (cfm) 2,210 Airflow (cfm/sgft) 2.83 Airflow (cfm/Ton) 473.6 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions JEATING SYSTEM PSYCHROMETRICS 26.0 of 68.8 OF 68.8 of Outside Air 0 cfm 68.8 OF 11.0 / 77.6 OF Outside Air 0 cfm 80.2/69.9 OF Total Room Loads Retum Vented Lighting Retum Air Ducts Retum Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK ICOILHTG.PEAK CFM I Sensible Latent CFM I Sensible 2,560 26,028 2,405 771 19,039 0 5,232 2,727 0 0 0 0 0 0 0 0 0 5,232 2,727 36,49 2,405 24 493 Existing 32,932 21,358 60,000 Total Adjusted System Output 32,932 21,358 60,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 aml earn Temperatures at Time of Heatina Peak) Supply Fan Heating Coil 2210 cfm 94.4 of Retum Air Ducts 80.2 / 69.9 OF 80.2 / 70.0 °F 66.2 / 65.3 OF Supply Fan 2210 cfm Supply Air Ducts 93.2 of ROOMS 70.0 of Supply Air Ducts Cooling Coil 68.4 / 66.0 of 64.9% R.H. ROOMS 78.0 / 69.2 of Retum Air Ducts I EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Paoe:9 of 10 1 LOAD SUMMARY PROJECT NAME Latrek Residence DATE 5/21/2007 SYSTEM NAME Living Zone FLOOR AREA 782 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mutt. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Addition Addition 1 1,077 10,945 1,176 1,077 10,945 1,176 267 6.584 Living Zone Existing Living 11 1,483 15,082 1,229 1,483 15,082 1,229 505 12,455 PAGE TOTAL 1 2,5601 2s o28 z,ao51 771 19,039 TOTAL 1 2,560 26,028 2,405 771 19,039 EnergyPro By EnergySoft User Number: User Job Number: Page:10 of 10