Loading...
RER (0208-345)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of -Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals.Code, and my License is in full force and effect. License # Lic. Class Exp. Date . 699640 B Date Signature of Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ); I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or Offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, • am exclusively contracting with licensed contractors to construct the . project '(Sec. 7044, Business & Professionals Code). 1 1.f » O I am exempt under Section B&P.C. for this reason; Ni Date ✓✓ Kc, `Signature of Owner -`7, n WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' L compensation, as provided for by Section' 3700 of the Labor Code, for the performance of the work for which this permit is issued. j( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are:. Z Carrier Policy No. 5 13TH E :FUND 046-00 0006397 (this -section need not be completed if the permit valuation is for $100.00 or less) ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those.provisions. „ate: w Applicant- -7->_ Warning: Failure to secure Workers':Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 ' of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety fora permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at' Whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicator agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives' of this City to enter upon the above-mentioned property for inspection purposes. ' Signature (Owner/Agent)°te� 7 '" � i; !� Date - L - J •� :BUILDING PERMIT PERMIT# - _. DATE. s� t VALUATION LOT ; 4 TRACT 3449 a' rpt iio s _ ,. c J • iG_! r.': — i JOB SITE — ADDRESS . .��;.JI) A..�fii�IS���C�4 APN OWNER CONTRACTOR/DESIGNER/EN INEER . I.Tq p A y,� �/ 4q HOMMp &Cyd-3+iSp���i,L"i�.��FwAy.��pJ.hi`A�`�J,+E Kr y ���y �,�µ7 p�y���T�� ), 'Af, - �{•�Y.•{S•J,Vy�•r�!1..�✓�Lry`i ,101'tl1 .f�Je. �y.S�' M.OL�td.TRO rAmaNT yJYA•gr��7J�.rys ' J SJ�J:yYA of .fr VM•.^.3d j , yt �•p•7'9��9t�.3 •�C�7,1y�7erpFdahLVB°..�A }n. �jy� !u•A QU.Ul�E. rA i+i'1 92255 +. ��•• pf..Cv 92,262 5�i•.pp����{{ ylq vigil ry PALM SYM 3 a • cA 92262 � (766)416�1144 USE OF PERMIT 30,=010D irk. Olt Ckle`OCX?e,; TO .V►9'sD1TYL N - Sulpprimi t aW is pa$trA 0204 2841 *6�S e qA 2nd RV rilelidop) CO41MACT .AMOVNT I$ ,. MISCELLANEOUS 101-000-423-000 SIVA CYNS1:'RtJC'i`I014 KZ 1.61-6iIt-418 000 99.Ot� PLA13 CIO= FEE 1634MID-439s1318 ;Ni.,.f~ C irROSIT 101-000-439"3l tq "�n30,lJO 5''S ipOiC# MOT1014 f:fl:1 .1211.2 1€1 •000r41=000.S0 1 1; AND • D .. �.._.�-. •",`• .LdMIS �:Y 63S^.CJ•2,LL.�.R�i �e! ei1.u: L`r F.!5.i APR 15 2001' 11MIT Fli S DIN NOW CITY OF LA QUINTA FINANCE•t3EPT. RECEIPT DATE '4 By DATE FINALED INSPECTOR 0 INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck % Z Exhaust Fans O.K. to Wrap • /p - y F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Z Final Final POOLS - SPAS BLOCKWALL APPROVALS Steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping_ Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster .Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final COMMENTS: �•�a4.2 i'L�ii~ �� ®% �"-?-—� ell XiR 4 v d J 'L,j !d _ 2 1/ - S Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring _ Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) i 913cy z, 3PL/Cor 40 FI.J"r r ir. cl 10 *Vr�-z V.,�44jil 44V 4 14 .in # Permit # Project Address: City Of La Quinta Building &r Safety Division P.O.Box1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet 45, 0%%-ner*s Name: A. P. Number: Legal Description: Address: ji 4J. c, 4-v City. ST. Zip: L Contractor:— Telephone: 4— Address: -44 `7 DU -9'L> L) Q s PrqiectDescr'iption: (kk - City, ST. Zip: CL cg� Tel Y. ...................... . ......... ........ ........ ...... State Lic. 4 p, 4, 1 C1, q &cj 0 City Lic. #: Arch.. Engr., Designer: Address: IV07'6 '* at 1/z ;-7—, wt --r- 111b7a 7 City, ST, Zip: C/41vr 10M, 764, 007,-05- �A. RN&W E-/Av -7" bA-f NOT I- 7-b CArf Telephone: State Lic. #: Name of Contact Person: . ...... ............. ...................... ........... I Construction TN pe: Occupancy: Project type (cir cle one New Add'n Alter Repair Derno Sq. Ft.: -Ilk Stories: # Units: Telephone # of Contact Person: z-7 Estimated Value of Project: J13 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets 2 Plan Check submitted ?v Item Amount Structural CaIcs. Reviewed, ready for corrections Plan Check Deposit Truss CaIcs. Called Contact Person Plan Check Balance Title 24 CaIcs. 2- Plans picked up Cj iConstruction Flood plain plan Plans resubmitted all Mechanical Grading plan 2"' Review, ready fo(c orrectionsli Electrical Subcontactor List Called Contact Person ------ Plumbing Grant Deed Plans picked up Ab/w(0S.M.I. H.O.A. Approval Plans resubmitted qJ/II lj Grading IN HOUSE:- Review, ready for correctio /iss rZ Developer Impact Fee Planning Approval Called Contact Person —M56 3.' .W V'IVA A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees lip A rdL 9 Total Permit Fees 913cy z, 3PL/Cor 40 FI.J"r r ir. cl 10 *Vr�-z V.,�44jil 44V 4 14 REGISTERED INSPECTOR'S WEEKLY REPORT JON TANDY � < 78-194 Elenbrook Ct. N' Palm Desert, CA 92211 Office (760) 772-7192 Fax (760) 772-7193 Pager (760) 776-3338 TYPE OF INSPECTION PERFORMED O REINFORCED CONCRETE O'S74LICT. STEEL ASSEMBLY ❑U�� ❑ POST TENSIONED CONCRETE D ASPHALT HER o6— ❑ REINFORCED_ MASONRY O FIRE PROOFING JOB LOCATION J P , �„� ` 1 e� ^ o 1 i tlD �w l j,, iJ ,PERMIT REPORT SEQUENCE N0. TYPE OF TRUCTURE 0. ��� D E � � DAV OF WEEK "MATERIAL DESCRIPTION ARCHITECT - 1 TO HRS. CHARGED ENGINEER ASSISTANTS HRS. CHARGED INSPECTION GENERAL{� ��11� SUB �� DATE - -- CONTRACTOR- �.-� v � �:�V' = -CONTRACTOR s . / n - 6dwt--.S.' 0 4-1 C 4.1 Lj I WF� 11� ec e to - COPY SENT TO.CLIENT O - CONTI E N NEXT PAGE 0 PAGE "- OF CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE INSPECTED TO THE BEST OF MY KNOWLEDGE ALL OF THE ABOVE REPORTED WORK UNLESS OTHERWISE NOTED. I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS. AND APPLICABLE SECTIONS OF THE GOVERNING BUILDING LAWS. ' G ROE OF REGISTERED,INS CTO �q'_75 D TE OF REPO/1R,T ,�R�E[GI�SSTER NUMBER 0 mom`. JON TANDY 78-194 Elenbrook Ct. Palm Desert, CA 92211 Office (760) 772-7192 INSPECTIONFax (760) 772-7193 REGISTERED INSPECTOR'S WEEKLY REPORT Pager (760) 776-3338 TYPE OFroo INSPECTION PERFORMED REINFORCED CONCRETE STRUCT. STEEL ASSEMBLY O �t P�,'l POST TENSIONED CONCRETE ASPHALT -P QTHER _ ✓]L REINFORCED_ MASONRY ❑ FIRE PROOFING" ,p G „`��yl JOB LOCATION /�� Cfj5 ft,D, `. TEe D LA OJ IGF �P►EVRlM1T�1�O� REPORT SEQUENCE NO. TVP �RE i..J� AR—Q ^PT ^ �r S D _ r, DAY OF WEEK MATERIAL DESCRIPTION ARCHITECT INSP TORO�C HRS. CHARGED ENGIN `Q M , /� ` ASSISTANTS HRS. CHARGED ///��� INSPECTION GENERAL -, 1 NTRA (J� �,_rDATE _ _ CONTRACTOR U•f 1p� � C.ONTAACTOR a 66 Lyuekc�s I11-11 I& � 1i� P 10 u GZ U All tAa& �Lb4, crams u ify ito ' TV a �. O - S S?"ArifcrJe-.((. ►�2ye5 � 06-1 ��� COPY SENT TO CUFNTO CONTINU ON NEXT PAGE O PAGE OF CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE INSPECTED TO THE BEST OF MY KNOWLEDGE ALL OF THE ABOVE REPORTED WORK UNLESS OTHERWISE NOTED. I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS. SPECIFICATIONS. AND APPLICABLE SECTIONS OF THE GOVERNING BUILDING LAWS. l� S N T RE OF REGISTEREDI S ECTOR -o .Di�Td OFO FOEPORT REGISTER NUMBER to rcRnS 003 :)in:) A911 3 N 3 -TJT.LE-24 REPORT Title 24 Report for: 49963 Avenida Montero.,'* La Quinta, CA 92253 Project Designer:- - Jim Jennings Architecture 49 Rodgers Alley San'Francisco. CA 94103 Report Prepared By: Jon Mitguard ENERGY CALC Co. 3255 KERNER BLVD., #5 SAN RAFAEL, CA 94901 (415) 457-0990 CITY, OF LA QUINTA BUILDING & SAFETY DEPT Job Number: DAM By 6/19/02 The Energ*yPro computer program has been used to perform the calculations sumtnarized in this compliance report. This program has approval -an ' d is - authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by-EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: 0313dima User Number. 1005 � J a Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Dimare Residence (Existing+Addition) 6/19/02 Project Title Date _ 49963 Avenida Montero La Quinta Project Address Building Permit # ENERGY CALC CO. (4.15) 457-0990 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agencv Use Onlv 'GENERAL INFORMATION Total Conditioned Floor Area: 5;764 ft2 Total Conditioned Slab Area: 0 ft, Building Type: (check one or more) - r Average Ceiling Height: 9.3 ft ® Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ® Existing Plus Addition • i Front Orientation: (East) 112 deg Floor Construction Type: ❑ Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 2 ® Raised Floor FENESTRATION Shadina Devices Type Orientation Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) R -30'C' Roof (R.30.2x10.16) Wood 0.035 Exterior Roof R-13 Wall (W.13.2x4.16) Wood 0.088 Exterior Wall RA 9 Floor (F.19.2x8.16) Wood 0.038 Exterior Floor / Over Crawlspace (w/R-6 Credit) R-13 Double Wall w/ply Wood 0.045 Exterior Wall R-19 Wall w/ply Wood 0.058 Exterior Wall Default Existing Roof Wood 0.047 Exterior Roof Default Wall Prior to 1978 Wood 0.386 Exterior Wall. Default Floor Over Crawl Prior To 1991. Wood 0.098 Exterior Floor / Over Crawlspace (w/R-6 Credit) X❑ ❑ X❑ Front (East) FENESTRATION Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF Shadin Yes / No Yes / No Skylight 18.0 0.94 0.73 None ❑ x❑ ❑ x❑ Left (South) 9.0 0.51 0.59 Bug Screen x❑ El El 0 Rear (West) 9.0 0.51 0.59 Bug Screen X❑ ❑ ❑ x❑ Front (East) 4.0 0.51 0.59 Bug Screen❑ X❑ ❑ X❑ Front (East) 85.0 0.72 0.70 Louvered Sunscreen ❑ x❑ ❑ ❑x Left (South) 8.0 0.51 0.59 Bug Screen Q X❑ ❑ x❑ Rear (West) 42.8 0.51 0.59 Bug Screen ❑ x❑ ❑ . ] Rear (West) 170.0 0.72 0.70 Louvered Sunscreen ❑ x❑ ❑ ❑x Right (North) 12.3 0.68 0.59 Bug Screen ❑ X❑ ❑ ❑x Front (East) 187.6 0.72 0.70 Bug Screen ❑ x❑ ❑ x❑ Left ' (South) 156.6 0.72 0.70 Bug Screen ❑ a ❑ a Rear (West) 383.0 0.72 0.70 Bug Screen ❑ . x❑ ❑ ❑x --~Run Initiation Time: 06/191021.1:23:14. Run -Code: 1645 10994- _ Ene'rqyPro 3.1 By Ener Soft . User Number: 1005 - Job Number. 0313dima Pa e:3 of 16 Certificate of Compliance: Residential (Part2 of 2) ' CFA R Dimare Residence (Existing+Addition) 6/19/02 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping ' Thermostat Location / pump, etc.) (AFUE/HSPF.)(ducts, attic, etc.) R -Value Type Comments f:Pntral FijmarP 78%AFUE Duck in Attic 42 Setback Res HVAC Cooling Equipment Minimum Duct c ' Type (air conditioner, Efficiency Location ' Duct ', Thermostat . Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments No Cooling t 10.0 SEER Ducts in Attic ' d2 SPthark RPs HVAC WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater, Distribution # in Input Cap. .or RecoveryStandby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss ('/e) R -Value Standard Gas 50 gal or Less Small Gas Standard 1 '40-000 50 0-58 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. - REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by -the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: 1JI VnA �r �L : Name:. Jon Mitguard Title/Firm: Jim Jennings Architecture . Title/Firm: ENERGY CALC CO. Address: 49 Rodgers Alley Address: 3255 KERNER BLVD., #5 San Francisco, CA 94103 SAN RAFAEL, CA 94901 Telephone: 415 551-0827 'Telephone: 15 457-0990 • (signature) (date) (signature) (date) . Enforcement Agency Name: Title/Firm: Address: Telephone: ___ - Run__ Initiation Time: 06/1g/02J1:23:14 Run Gooe: 1u�45tQ994 EnergyPro 3.1 By EnergySoft User Number: 1005 Job Number: 0313dima Page:4 of 16 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE:. Low rise residential buildings subject to the; Standards must contain these measures regardless of -the compliance approach used. Items,marked-with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures '§ 150(.): Minimum R-19 ceiling insulation. §150(b): Loose fill insulation manufacturer's labeled R -Value. ®•§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). ❑'§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. ❑§150(1): Slab edge insulation -water absorption rate ho greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. ® § 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® § 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. .. ❑ §150(1): Special infiltration. barrier installed to comply with Section 151 meets Commission quality standards. ❑ §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: x .a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ®§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. j ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ § 1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2: First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) I 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemal/extemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. Insulated. 6. Piping insulating between heating source and indirect hot water tank. .By �EnergyPro 3.1 EnergySoft ' User"Number. 1005 Job Number. 0313dima~ Page:5"of 16 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R -NOTE: Lowrise residential buildings subject to the.Standards must contain these;measures regardless of the compliance i0ip,6 eh used: Items marked with. an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is Incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are . shown elsewhere in the documents or on this checklist only. . DESCRIPTION 'Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) X1 I150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum Installed level of R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL1B1A, or UL181B. If mastic or tape Is used to seal openings t greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used In combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for.conveying conditioned air. Building r cavities and support platforms may contain ducts. Ducts installed.in cavities and support platforms shall not be compressedto cause reductions in the cross-sectional area of the ducts. r 3. Joints and seams of duct systems and their components shall not be sealed with Goth back rubber adhesive' _ duct tapes unless such a tape is used in combination with mastic and drawbands. . 4. Exhaust fan systems have back draft or automatic dampers., 5. Gravity. ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually, operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, Including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas; or plastic cover. Cellular foam " insulation shall be protected as above or painted with a coating that Is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance <. heating, and no pilot. 2. System is installed with at least 36' of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has -directional inlets and a circulation pump time switch... ' ❑ §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no ' continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria I Lighting Measures ❑ § 150(k)1: Luminaires for general lighting in kitchens shall have tamps with an efficacy 40 lumens/watt'or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. a§150(k)2: Rooms with a shower or bathtub must have either at least one luminalre with lamps with an efficacy of 40 lumens/watt-or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 . By EnergySoft User Number: 1005 Job Number: 0313dima Page:6 of 16 f r Computer Method Summary (Part 1 of 3) C -2R D are esidence (ExistinpAddition) Project Title 6/1 g/p2 Date uinta Project Address Building Permit # ENERr7,Y CAI C CO (415) 457-0990 Documentation Author Telephone plan Check/Date �omputer�edormance 15 Field Check/Date Compliance Method (Package or Computer) I Climate Zone Source Energy Use Standard Proposed Compliance ' (kBtu/sf-yr) Design Design Margin Existing+Addition Budget Adjustment Space Heating 3.75 10.45 -6.70 Ratio F: 4158 / 5764 = 0.721 Space Cooling 32.17 84.40 -52.23 Budget Adj: 0.721 X (125.68 - 44.22) '= 58.77 Domestic Hot Water 4.94 4.50. 0.45 The budget shown to the left has been Increased using Totals 58.77 + 40.87 = 99.64 99.35 0.29 this Budget Adjustment based upon Existing building Infnrtnatinn shown nn'fhw f19R which fnllnwe lhie f ­ GENERAL INFORMATION Conditioned Floor Area: 5,764 Building Type: Single Fam Detached Building Front Orientation: (East) 112 deg Number of Dwelling Units: 1.00 Number of Stories: 2 Slab Floor Floor Construction Type: X❑ Raised Floor Total Fenestration Area: 18.8% Total Conditioned Volume: 53,477 Slab Floor Area: 0 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area ResHVAC 5,764 53,4n 1 nn ConditinnPd Setback —$ .—n[a OPAQUE SURFACES Solar Act. Gains Type Area U -Fac. Azm. Tilt Y / N Rnnf 66 0.035 112 o ® ❑ wall 76 0.088 q02 gn ® ❑ Wall 71 0.088 292 qn ® ❑ Flnn •G 71 o.03R _a Igo Rnnf 1,526 0.035 112 a ❑ Wall 764 0.045 112 gn Igo ❑ Wall 242 0.058 202 go Al ❑ Will 640 0.045 292 90' ® ❑ Wall 238 0.058 22 gn X ❑ Roof 2,624 0.047 112 n EX ❑ Wall 861 0.386 112 gD_ EXI ❑ Wall 323 0.386 202 go ®'❑ Wall 666 0.386 q92 X11 X ❑ Wall 480 0.386 _22 cin � EJ Flnorr- 4,158 0 09 .8 _ 0 180 Form 3 Reference R -30'C' Roof (R_302x10.16) Addition R-13 Wall (W -132x4.1 Addition R-13 Wall (W. 132x4.161 AdditiOn R-19 Floor (F -192x8.16) Addition R -30'C' Roof ($_302x10.16) Additinn R-13 Dnuhle Wali w/ply Addition R-19 Wali w/ply Aridition R-13 Douhle Wall w/ply Addition R-19 Wali w/ply Addition Default Existing Roof FX*Sting Default Wali Prior to 1978 Fxisting i Default Wall Prior to 1978 FXISting I Default Wall Prior to 1978 FXlsting Default Wail Prior to 197A Existing Default Flnor Over Crawl Prior To 1991 Existing Location / Comments ❑ ❑ ❑ ❑ ❑❑ Run lnitiation.Time: 06/19/02 11:23:1.4•: Run Code: 1024510994 EnergyPro 3.1 By EnergySoft User Number: 1005 Job Number: 0313dima #Page:7 of 16 Computer Method Summary (Part 2' of 3) C -2R Dimare Residence (Existing+Addition) 6/19/02' Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor ' SHGC Azm. Tilt Comments -L Skylight Front (East)_ 9.0 0.940 073 112 _ n Douhle Metal Default Addition 2 Window Left (South) 9.0 0.510 0.59 202 90 Milgard Double (Metal) Low -E Addition 5 Window Rear (West) 9.0 0.510 0.59 292 90 Milgard Double (Metal) Low -E Addition 4 Skylight Front (East) 9.0 0.940 0.73 112 _ 0 Double Metal Default Addition 5 Window Front (East) 4.0 0.510 0.59 112 90 Milgard Double (Metal) Low -E Addition 5 Window Front (East) 85.0 0.720 0.70 112 _ 90 Milgard Double (Metal) Low -E Addition Z Window Left 8.0 0.510 0.59 _202 90 "ard Double (Metal) Low -E Addition 8 Window Rear (West) 42.8 0.510 0.59 292 90 Milgard Double (Metal) Low -E Addition _9- Window Rear est) 170.0 0.720 0:70 292 90 Milgard Double (Metal) Low -E Addition A -Q Wil- ow Right (L odd 12.3 0.680 0.59 22 90 "ard Double (Metal) Low -E Addition 11 Window Front (East) 187.6 0.720 0.70 112 90 Existing Double Metal Existing 12 Window Left (South) 156.6 0.720 0.70 202 90 Existing Double Metal Existing Aa Window Rear (Wast) _ 383.0 0-720 0.70 _ 292 90 Existi g Douhle Metal Fx*qtong WINGbI W cti 0.7272 - WIMov.J 2- W) 2-_.S 0 72 - WlNoow W) !3'1S _0.S) W I1v,00vJ UJ 0 72 UJ(r"IxvJ S Ow) 2 f 0.57 (NINvo J II.53 0--n - o•-7 - UJINb:�JJ 9 E) �42•S o-72 Wlnnooc-i 14 A) N0 c2.51 - - bJ I'y001 J I I �S) e(- 0 O. S) INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 None .00-2 1.00- 2 Bug Screen 0.76 9.0 1.0 8.0 0.1 8.0 8.0 3 Buq Screen 0.76 9.0 1.0 8.0 0.1 8.0 8.0 4 None 1.00 5 Bug Screen 0.76 6 Louvered Sunscreen 0.27 7 Bug Screen. 0.76 8 Bug Screen 0.76 9 Louvered Sunscreen 0.27 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 _ Co PJ:T Mrx0tJ 12 E) I.0Q,CI. - 13 CF ►.o 0.91 UJItv00v;J:IV (- 1.0 O.V - w I rJ,�,OvJ • 1 S (EJ 1.0 _ SV-gW RT I 9,o 0 - )roc I(- W) J.v o,51 - - o r 7 q•O Run Iii•i 24510994 Ene'ravPro 3.1 By EnergySoft User Number: 1005 Job Number: 0313dima Page:8 of 16 Computer MethodSummary (Part 3 of 3) C -2R Dimare Residence (Existing+Addition) 6/19/02 Project Title Date ' THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R=Val. Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments HVAC SYSTEMS Heating Equipment Minimum 'Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location/ pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 78%AFUE Ducts in Attic 4-2 Setback Res HVAC Hydronic Piping Pipe Pipe Insula System Name Length Diameter Thick. Cooling Equipment Minimum Duct _ Type (air conditioner, Efficiency Location Duct Thermostat Location / ' heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments No Cooling 10.0 SEER Ducts in Attic 4.2 Setback Res HVAC WATER HEATING SYSTEMS Ratedl ` Tank Energy Fact! 1 Tank Insult • Water.Heater Water Heater Distribution # in . Input Cap. or Recovery Standby - R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. Standard Gas 50 gal or Less Small Gas Standard 1 40,000 50 0.58 n/a n/a 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. . For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. ' RFMARKC _ Computer Method Summary (Part 1 of .3),,- C -2R -Uma ciSting) 6119102 Project Title Date A99-63 Monern I a Quonta Project Address Building Permit # ` -ENERGY-CAI C C0 (415) -457-0990 Plan Check/Date Documentation Author Telephone �Amputer_Performance 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating' 3.43 12.57 -9.14 Space Cooling 33.93 106.88 -72.95 Domestic Hot Water 6.85 6.23 0.62 Totals 44.22 125.68 -81.46 GENERAL INFORMATION Conditioned Floor Area: 4,158 Building Type: Single Fam Detached Building Front Orientation: (East) 112 deg Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Slab Floor Floor Construction Type: X❑ Raised Floor I Total Fenestration Area: 17.5% Total Conditioned Volume: 37,422 Slab Floor Area: 0 BUILDING ZONE INFORMATION # of Zone Name Floor Area Volume Units Zone Type Ras HVAr d158. ' 37 422422 1 nn cnriditinned Solar' OPAQUE SURFACES Act. Gains Type Area U -Fac. Azm. Tilt Y / N Rnnf 4158 0-047 112 —0 W;1I1— 861 0-386 112 An Wall 323 0.386 _202 An WAW 666 0.386 292 90 Wall 480 0-386 92 90 ,lpnrC$ 4158 0-098 _fl 180 EnergyPro 3.1 By EnergySc Form 3 Reference /. ■11111119TIFT-.• User Number: 1005 Thermostat Vent Type Hgt. Area Sathar.k _2 n/a Location / Comments fisting Existing Existing FxisLng – Fxigting 1.1:23:14, Run Code: 1024510994 Job Number: 1018dim 10 of 16 F r. Computer Method Summary (Part -2 -of 3) C -2R Dimare Residence (Existing+Addition) 6/19/02 " Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments -j— Window Front (Fggt)_ 1f37.6 n 720_ n7n 112 A0. Existing ❑nu61e Metal Existing 2 Window Left (South) 156.6 0.720 0.70 202 90 Existing Double Metal Existing 2 Window Rear (West) 383.0 0.720 0.70 292 90 Existing Double Metal' Existing INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. , Hgt. LExt. RExt. Dist. Len. Hgt Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 _ 3 Bug Screen 0.76 Run Initmation Time* 06/19/02 .11 -RunCodee-1024510994-, EnergyPro 3.1 By EnergySoft User Number: 1005 • Job Number: 0313dima Page:11 of 16 r Computer Method Summary (Part 3 of 3) C -2R Dimare Residence (Existi ng +Addition) 6/19/02 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. . Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments HVAC SYSTEMS ' Heating Equipment Minimum• Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / ,pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 78%AFUE Ducts in Attic 4-2 Setback Res HVAC Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency, Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments No Cooling' 10. O SEEB :: Ducts in Attic 4.2 Setback Res HVAC WATER HEATING SYSTEMS i 1 Rated � Tank 1 Energy Fact.. Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) ! (gal) Efficiency Loss (%) Ext. Standard Gas 50 gal or Less Small Gas Standard 1 40,000 50 0.58 n/a n/a 1 For small gas storage (rated input — 75000 Btuthr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 06/19/02.11:23:14: • Run.Code: 1024510994 EnergyPro 3 1 By EnergySoft User Number. 1005 'Job Number: 0313dima Page: 12 of 16 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME Dimare Residence (Exi DATE 6/19/02 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Roofing, Asphalt Shingles 2 Membrane, Vapor -Permeable Felt 3 Plywood ASSEMBLY NAME IR -30 'C' Roof R.30.2x10.16 5 Insulation, Mineral Fiber, R-30 High Densi 6 Gypsum or Plaster Board ASSEMBLY Floor 0.17 2.85 9 TYPE (check one) Wall INSIDE SURFACE AIR FILM 0.610 G 12.25 X Ceiling /Roof N FRAMING MATERIAL yyj p FRAMING % 10 Framing /o 2.6 - 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c: Floor/Cell.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Cell.) SUBTOTA a R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Roofing, Asphalt Shingles 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Air Space 5 Insulation, Mineral Fiber, R-30 High Densi 6 Gypsum or Plaster Board 7 0.39 0.17 2.85 9 t 2.08 INSIDE SURFACE AIR FILM SUBTOTA a R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.4401 0.440 .0.060 0.060 0.620 0.620 0.770 1.485 30.0051 8.415 0.450 0.450 0.39 0.17 2.85 0.36 t 2.08 0.610 0.610 33.12 12.25 Rc IAI IB *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) ' HC (A X B) (Btu/F-sf) [ 0.0302 x 0.90 ] 1.46 0.30 0.44 0.06 0.35 0.02 1.42 0.29 0.41 0.441 0.39 0.17 2.85 0.36 1.03 2.08 0.26 0.54 8.3 TOTAL HC 2.6 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing Include the effects of the framing members. [ 0.0302 x 0.90 ] + [ 0.0816. x 0.10 1 I Rc 1 = (Fr% / 100) 11 Rf Fr% 1100 ASSEMBLY LI -VALUE COMMENTS v J EnergyPro 3.1 By EnergySoft User Number: 1005 Job Number: 0313dima 3of16 i PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME Dimare Residence r DATE }Addition) 6/19/02 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM ' Cement Fiberboard 2 Air Space 3 Membrane, Vapor -Permeable Felt 4 Plywood ASSEMBLY NAME R-13 Double Wall w/ply 6 Insulation, Mineral Fiber, R-13 7 Gypsum or Plaster Board s 0.41 ASSEMBLY Floor 0.62 INSIDE SURFACE AIR FILM 0.680 28.87 TYPE (check one) X Wall 0.54 W 0 W Ceiling I Roof NFRAMING MATERIAL Wood O= ? FRAMING % 15 % Framing % 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10%(1 6" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Cell.) SUBTOTA Rc R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Cement Fiberboard 2 Air Space 3 Membrane, Vapor -Permeable Felt 4 Plywood 5 Insulation, Mineral Fiber, R-13 6 Insulation, Mineral Fiber, R-13 7 Gypsum or Plaster Board s 0.41 s 0.37 0.62 INSIDE SURFACE AIR FILM SUBTOTA Rc R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170. 0.170 0.050 0.050 0.840 0.990 0.060 0.060 0.620 0.620 12.999 3.465 12.999 3.465 0.450 0.450 0.41 1.68 0.37 0.62 0.680 0.680 28.87 2.08 'HEAT CAPACITY (Optional) penetrated by wood framing WALL WEIGHT (lbslsf) SPECIFIC rHEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) 0.85 ] + 2.42 0.20 0.48 0.44 0.39 0.17 0.06 0.35 0.02 1.42 0.29 0.41 1.68 0.37 0.62 1.68 0.37 0.62 2.08 0.26 0.54 9.95 Rtl i 9.8 TOTAL HC 2.9 TE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members.. 0.0346 X 0.85 ] + [ 0.1005 X 0.15 ] _ 0.045 1 / Rc 1 - (Fr% /100) 1 / Rf Fr% 1100 ASSEMBLY U-VALL J PROPOSED CONSTRUCTION ASSEMBLY ENV -3 NAME Dimare Residence (Existing+Add DATE 6/19/02 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM ASSEMBLY NAME R-19 Wall w/ply Cement Fiberboard 2 Air Space ASSEMBLY Floor Membrane, Vapor -Permeable Felt 4 TYPE X Wall (check one) 5 W W O Ceiling I Roof Gypsum or Plaster Board 7 FRAMING MATERIAL yyood 0.41 O= ? FRAMING % 15 % o Framing /o 0.98 ` 15% (16" o.c. Wall) 0.680 20.78[-- 0.78 12% (24" o.c. Wall) 10% (16" O.C. Floor/Cell.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Cell.) C SUBTOTA R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Cement Fiberboard 2 Air Space 3 Membrane, Vapor -Permeable Felt 4 Plywood 5 Insulation; Mineral Fiber, R-17.8 6 Gypsum or Plaster Board 7 0.291 0.41 2.63 E98 0.98 2.60 INSIDE SURFACE AIR FILM SUBTOTA R -VALUE CAVITY R -VALUE (Rc) _ WOOD FRAME R -VALUE 0.170 0.170 0.0501 0.050 0.840 0.990 0.060 0.060 0.620 0.620 17.800 5.445 0.562 0.562 0.291 0.41 2.63 0.37 0.98 2.60 0.680 0.680 20.78[-- 0.78 8.58 �0�M *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) 0.0481 x F 0.85 ] 2.42 0.20 0.48 0.44 0.39 0.17 0.06 0.35 0.02 1.42 0.291 0.41 2.63 0.37 0.98 2.60 0.26 0.68 9.6 TOTAL HC 2.7 Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. 0.0481 x F 0.85 ] + [ 0.1166 x 0.15 1 / Rc 1 - (Fr% 1100) 11 Rf Fr% 1100 ASSEMBLY U -VI 3.1 By EnerovSoft User Number: 1005 Job Number: 0313dima of 16 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Dimare Residence(Existing +Addition 6/19/02 - SYSTEM NAME FLOOR AREA - Res HVAC 5,764 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent I I CFM I Sensible 210 217 -4179 17�181 387 ig FAU 0 0 396,000 Total Adjusted System Output 0 0 396,000 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 2 pm an 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 68.8 OF 68.8 OF 105.OoF O Supply Air Ducts --� Outside Air 0 cfm 103.8 of Supply FanHeating Coil 6580 cfm'* ROOMS 68.8 of 70.0 OF Retum Air Ducts I COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 115.9/73.5 OF 79.4/61.9 OF 79.4/61.9 OF 55.0/53.0 OF OSupply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 56.4 / 53.6 of 6580 cfm 38.7% R.H. ROOMS 79.4/61.90F 78.0/61.4OF Return Air Ducts I FlEnergyPro 3.1 By EnergySoft User Number: 1005 Job Number: +0313dima Page:16 of 16