Loading...
11-0323 (RER)P.O. BOX 1504 4� 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number:{x-11-000 0 0 3 23.- l Owner: Property Address: `51980 AVENIDA MORALES PERRY SHERRON & KELLY APN: 773-152-012-13 - - PO BOX 1408 Application description: REMODEL - RESIDENTIAL GIRDWOOD, AK 99587 Property Zoning: COVE RESIDENTIAL Application valuation: 35000 Contractor: Applicant: Architect or Engineer: LANDRY, BRAD 874 BORDER #D-16 JOSHUA TREE, CA 92252 (760)218-0357 Lic. No.: 816900 -------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION ' I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. lice se Class: B C1110 ense No.:- 816900 OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves the_reon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). . ( I I am exempt under Sec. , B.&P.C. for this reason . Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/17/11 D anni MAY 19 2011 CITY OF L A QUINTA FII'' iNC,E DEPT. ----------------------------------------------- WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided - for by Section 3700 of the Labor Code, for the performance of the work for which this permit is ' issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EX MPT Policy Number EXEMPT certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forth mply with those provisions. . te: ( ll- 9ppticant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. - APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. - - 1 . Each person upon whose behalf this application is made, each person at whose request and for -whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner,'and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter ' upon the above-mentioned property for inspection f7a��. tature (Applicant or Agent): Application Number . . . . . 11-00000323 ------ Structure Information REMODEL W/210SF PATIO COVER [ENG] ------ ---=Other Otherstruct info . . . . . CODE EDITION 2010 Permit BUILDING PERMIT INV FEE Additional desc . Permit Fee 634.00 Plan Check Fee 206.05 Issue Date . . . . Valuation . . . . 35000 Expiration Date 11/13/11 Qty. Unit Charge Per 'Extension BASE FEE 504.00 10.00 13.0000 THOU BLDG 25,001-50,000 130.00 Permit . . . ELECT -.ADD/ALT/REM INV FEE Additional desc . Permit Fee . . . . 79.80 Plan Check Fee 9.98 Issue Date . . . . Valuation . . . . 0 Expiration Date 11/13/11 Qty Unit Charge Per Extension BASE FEE 30.00 20.00 1.5000 PER ELEC DEVICE/FIXTURE'1ST 20 30.00 22.00 .9000 EA ELEC DEVICE/FIXTURE >26 ---------------------------------------------------------------------------- 19.80 Permit PLUMBING INV FEE Additional desc . Permit'Fee . . . . 78.00 Plan Check Fee 9.75 Issue Date Valuation 0 Expiration Date 11/13/11 Qty Unit Charge Per Extension BASE FEE 30.00 3.00 12.0000 EA PLB FIXTURE 36.00 1.00 6.0000 EA PLB'WATER INST/ALT/REP 6.00 1.00 6.0000 EA PLB GAS PIPE 1-4 OUTLETS 6.00 ---------------------------------------------------------------------------- Special Notes and Comments SCOPE OF INTERIOR REMODEL - CHANGE OUT WINDOWS AND CREATE ADDITIONAL OPENINGS, REMOVE AND REPLACE KITCHEN CABINETRY, LIGHTING AND APPLIANCES, RELOCATE WASHER AND DRYER. SCOPE OF EXTERIOR REMODEL - ADD 210SF PATIO TRELLIS AND INSTALL•GAS STUBS FOR BBQ AND FIREPIT AT FRONT YARD. LQPERMIT Application Number . . . . 11-00000323 ---------------------------------------------------------------------------- Special Notes and Comments [ENGINEERED] THIS PERMIT DOES NOT INCLUDE BLOCK WALLS, BBQ ENCLOSURE, ALTERATION OF INTERIOR WALLS OR HVAC CHANGE OUT. CODE CASE NO: 11-1827 [MR] ***INVESTIGATION FEE ASSESSED PER 2010 CALIFORNIA RESIDENTIAL CODE CHAPTER 1. §108.6 FOR WORK COMMENCING BEFORE PERMIT ISSUANCE*** 2010 CALIFORNIA BUILDING CODES. May 17, 2011 5:00:17 PM`AORTEGA ---------------------------------------------------------------------------- Other Fees .. . . . .. BLDG STDS ADMIN (SB1473') 2.00. ENERGY REVIEW FEE 20.61 STRONG MOTION (SMI) - RES 3.50 Fee summary Charged Paid Credited Due Permit Fee Total 791.80 .00 .00 791.80 Plan Check Total 225.78 .0.0 .00 225.78 Other Fee Total 26.11 .00 .00 26.11 Grand Total 1043.69 .00 00 1043.69 LQPERMIT . uui » + 1 City of La. Quinta Building 8T Safety Division Permit # P.O. Box 1504, 78-495 Calle Tampico c 3 La Quinta CA. 92253 - (760) 777-7012 Building: Permit Application and Tracking Sheet,.-,t . `- Project Address: ; c Owner's Name:.' - A. P. Number: Address: Legal Description: City, ST, Zip: ctor: Contra77 _„ ,,• R Telephone:. ' Address: •Project Description: City, ST, Zip: - TeleP hone: %' ...........:::.::.:::.::.::.::.::.::.:::::::::: State Lic. # :�.., '00 City Lic. #.: t -A -4 Arch., Engr., Designer: Address: •• /y e City,. ST, Zip:, - .s TeleP hone: . C on stru ' cti 0 nType: Occ u P anc Y,• o State� Lic. of Contact Person: ..............:::::::_::,: Proe ct le J tyPe (circle rc one): New, Add'n te 'Repair. a' t Demo.Name 0 Sq, Ft.:' #Stories: Units. Telephone # of Contact Person: Estimated Value of Project: • ` • APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd 'Reed TRACKING Plan Sets PERMIT FEES Plan Check submitted Item . Structural Calcs: Reviewed, ready for corrections 4,1 jp{( , Plan Amount Truss Calcs. Check Deposit r-- Called Contact Person Z q Plan Check Balance Title 24 Calcs. Plans picked up �_ Construction ` !� Flood plain plan Plans resubmitted Mechanical •, Grading plane 2'. Review, ready fo c rection ssue Electrical ,mop, Subcontactor List Called Contact Person rj1 Plumbing Grant Deed - Plans picked up - b � Q � S.M.I. H.O.A. Approval Plans resubmitted. �( a Grading IN HOUSE:- 'nd Review, ready for correctio i e046 Developer Impact Fee �. + Planning Approval Called Contact Person '� ' A.I.P.P. Pub. Wks. Appr. Date of permit issue ' a School Fees L o i _ y Total Permit Fees, 0 :7 I BUILDING ENERGY ANALYSIS REPORT . PROJECT: The Perry Residence 51-980 Ave. Morales La Quinta, CA 92253 Project Designer: BLC Construction Po Box 6854 La Quinta, CA 92253 (760) 218-0357 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 t►•a5�, cam+ CITY OF LA QUINTA BUILDING & SAFETY DEPT. Job Number: APPROVED FOR CONSTRUCTION DATE 401A BY Date: w►wt� wap•µ„ art .5/17/2011 11pi �I�� MAY 17 2011 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Energ Pro 5.1 by EnergySoft User Number. 6712 Run Code: 2011-05-17T15:00:30 /D: t • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name The Perry Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration California Energy Climate Zone Total Cond. Floor Area Addition CA Climate Zone 15 1,207 0 Date 5/17/2011 # of Stories 1 Project Address 51-980 Ave. Morales La Quinta FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-19 1,207 Existing Wall Wood Framed R-11 666 Existing Wall Wood Framed R-11 254 Existing Door Opaque Door None 20 Existing Slab Unheated Slab -on -Grade None 1,207 Perim = 145' Existing FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Left (N) 24.1 0.490 0.25 none none Bug Screen New Left (N) 40.0 0.490 0.25 none none Bug Screen Altered Right (S) 32.0 0.490 0.25 none none Bug Screen Altered Right (S) 50.3 0.480 0.76 none none Bug Screen New Front (W) 50.3 0.480 0.76 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Packaged Air Condition. 10.0 SEER Setback Existing HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status Exist HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-05-17T15:00:30 ID: Page 3 of 11 r1 U PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name The Peny Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 5/17/2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. EnerqyPro 5.1 by EnerqySoft User Number: 6712 Run Code: 2011-05-17T15:00:30 /0: Page 4 of 11 • • PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date The Perry Residence 1 ❑'Multi Family m Existing+ Addition/Alteration 1511712011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 4.16 5.87 -1.72 Space Cooling 209.23 143.39 65.84 Fans 43.51 30.41 13.11 Domestic Hot Water 22.29 22.29 0.00 Pumps 0.00 0.00 0.00 Totals 279.19 201.95 77.23 Percent Better Than Standard: 27.7% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (►M 270 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (K9 232 50 Fuel Available at Site: Natural Gas (N) 336 64 Raised Floor Area: 0 (E) 232 0 Slab on Grade Area: 1,207 (S) 336 82 Average Ceiling Height: 8.0 Roof 1,207 0 Fenestration Average U -Factor: 0.48 TOTAL: 197 Average SHGC: 0.51 Fenestration/CFA Ratio: 16.3% REMARKS Brad 760-218-0357 STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, J 5/172011 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company BLC Construction Address Po Box 6854 Name Brad Landry City/State/Zip La Quinta, CA 92253 Phone (760) 218-0357 Signed License # Date EnemvPro 5.1 by EnemySoft User Number: 6712 Run Code: 2011-05-17715:00:30 /D: Page 5 of 11 • • CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name The Perry Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1511712011 OPAQUE SURFACE DETAILS Surface Type Area Ll- Insulation Joint Appendix Factor CavitY7Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,207 0.049 R-19 0 22 Existing 4.2.1-A4 Altered Residence Wall 272 0.110 R-11 0 90 Existing 4.3.1-A2 Altered Residence Wall 232 0.110 R-11 90 90 Existing 4.3.1-A2 Altered Residence Wall 254 0.110 R-11 180 90 xisting 4.3.1-A2 Altered Residence Wall 162 0.110 R-11 270 90 Existing 4.3.1-A2 Altered Residence Door 20 1.450 None 270 90 Existing 4.5.1-A1 Altered Residence Slab 1,207 0.730 None 0 180 Existing 4.4.7-A1 Altered Residence FENESTRATION SURFACE DETAILS ID Type Area LI -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 40.2 1.190 Default 0.83 Default 0 Removed Single Metal Clear Altered Residence 2 Window 20.1 0.490 NFRC 0.25 NFRC 0 New Milgard Dual Metal Tint Altered Residence 3 Window 2.0 0.490 NFRC 0.25 NFRC 0 New Milgard Dual Metal Tint Altered Residence 4 Window 2.0 0.490 NFRC 0.25 NFRC 0 New Milgard Dual Metal Tint Altered Residence 5 Window 9.0 0.490 NFRC 0.25 NFRC 0 Altered Milgard Dual Metal Tint Altered Residence 6 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 7 Window 7.0 0.490 NFRC 0.25 NFRC 0 Altered Milgard Dual Metal Tint Altered Residence 8 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 9 Window 24.0 0.490 NFRC 0.25 NFRC 0 Altered Milgard Dual Metal Tint Altered Residence 10 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 11 Window 16.0 0.490 NFRC 0.25 NFRC 180 Altered Milgard Dual Metal Tint Altered Residence 12 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 13 Window 16.0 0.490 NFRC 0.25 NFRC 180 Altered Milgard Dual Metal Tint Altered Residence 14 Existing 1.190 Default 0.83 Default Single Metal Clear pre -altered for above 15 Window 50.3 0.480 NFRC 0.76 NFRC 180 New Milgard Dual Non Metal Tint Altered Residence 16 Window 40.0 1.190 Default 0.83 Default 270 Removed Single Metal Clear Altered Residence (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len HqA LExt RExt Dist Len H t Dist I Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 JBug Screen 1 0.761 1 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-17715:00:30 ID: Pae 6 of 11 • 0 OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R ProjectCERTIFICATE Perry Residence 0 Single Family ■ Addition Alone 0 Multi Family 10 Existing+ Addition/Alteration OPAQUEThe IPHIOII�� Joint Appendix �; 4 Location/Comments FENESTRATION SURFACE DETAILS MO, Milgard Dual Non Metal T—int EXTERIORIIN SHADING DETAILS Exterior Shade Type /I I ENEEMEj .. - • • CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name The Perry Residence Building Type D Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1511712011 BUILDING ZONE INFORMATION System Name Zone Name New Floor Area Existing Altered Removed Volume Year Built Exist HVAC Altered Residence 1,207 9,652 1985 Totals 1 01 1,207 0 0 HVAC SYSTEMS System Name Qt . Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Exist HVAC 1 Central Furnace 80% AFUE Packaged Air Conditione 10.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Cooling Duct Duct Location R -Value Ducts Tested? Status Exist HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing WATER HEATING SYSTEMS S stem Name Qty- Type Distribution Rated Input (Btu h) Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas No Pipe Insulation 34,000 40 0.58 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ff c 0 i� Q cS System Name Pipe Length Pipe Diameter Insul. Thick. Qty.FHP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-05-17715:00:30 ID: Page 8 of 11 'MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF -1 R Project Name The Perry Residence Date 1611712011 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used., More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. t 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150 50 f : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fire laces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is 4guipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. I - 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks forsolar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatina sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. ' §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. I . 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(i)4: Solar wate r -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-17715:00:30 ID: Page 9 of 11 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date The Peny Residence 5/17/2011 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be seated with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. ' EnergyPro5.1 by EnergySoR User Number: 6712 Run Code: 2011-05-17715:00:30 ID: Page 10 of 11 r r MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date The Perry Residence 1511712011 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high eff ica6y luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134 and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2011-05-17T15:00:30 /D: Page 11 of 11 wad. ko mp r 2,j 4b, CLIENT- RqberttA-,Pltch-Fordw Designer'- ' PROJECOT%. PERRYREMODEL -ADDRE55: 51980 Avenida MOraies Ta Oninta JOB: 12-222 qne DATE: 22 AOrl 12011 "tit NO RJEC!1EJVpr) • ,�''`'44 s s IS CD ': - '7)C ^) ©.� .. ,' Ska R * D 3' APR 22 2011 L jf fly ---STRUCTURAL AND CIVIL ENGINEERING 4' DENISE R. POELTLER, INC. 77725 ENFIELD LANE, STE. #130 PALM DESERT, CA 92211 I TEL. (760) 772-4411 • FAX (760) 772-4409 '7W drpfly@aol.com ,�''`'44 s s IS CD ': - '7)C ^) ©.� .. ,' Ska R * D