Loading...
BMCH2016-020078-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 T-dy4.fwQ,&rw COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BMCH2O16-0200 Property Address: 79664 MORNING GLORY CT APN: 604452025 Application Description: LORIA RESIDENCE / HVAC'CHANGE Property Zoning: Application Valuation: $16,000.00 Applicant: IE INC 31225 LA BAYA WESTLAKE VILLAGE, CA 91362 A JUN 0 9 2016 CITY OF LA QUINTA COMMUNITY DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C20, C36 License No.: 686310 `�• Com cf or-: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or.her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a•contractor(s) licensed pursuant -to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3b97, Civ. C.). Lender's N Lender's Address: ` VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 6/9/2016 Owner:' STEVEN LORIA 79664 MORNING GLORY CT LA QUINTA, CA 92253 Contractor: HARRISON ENTERPRISES INC DBA GENERAL AIR 31170 RESERVE DRIVE THOUSAND PALMS, CA 92276 (760)343-7488 Llc. No.: 686310 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. �' I have and will maintain workers' compensation insurance, as`required by Section 3700 of the Labor Code, for the.performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date:(o ft(�A plicant: +l� WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. Dagt;: �i I to Signatu a(Applicant or Agent): Slzzsz_ INFORMATION DESCRIPTION .: ACCOUNT CITY $ AMOUNT PAID . ' ' PAID DATE BSAS SB1473.FEE 101-0000-20306 0 $1.00 $0.00 PAIDBY F %",METHOD t> RECEIPT# #�$ CHECK# CLTD"BY Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $0.00 x tDES CRIPTION .A ACCOUNT ' ,QTY .i -':AM OUNT^ PAID PAID DATE' HVAC CHANGEOUT - SPLIT -SYSTEM 101-0000-42402 0 $145.04 $0.00 PAID BY ;' "METHOD ' ��_ -RECEIPT # ; CHECK # .; LLTD BY s PAID DATE i. DESCRIPTION ACCOUNT AMOUNT. PAID HVAC CHANGEOUT - SPLIT -SYSTEM PC 101-0000-42600 0 $72.52 $0.00 Y PAID BY 3, ; ' METHOD "' ' *RECEIPT # ., CHECK # CLTD BY Total Paid for CHANGEOUT: $217.56 $0.00 DESCRIPTION: ACCOUNT, QTY'., AMOUNT'S PAID <` DATE ,PAID PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 PAID BY > . Y.: �. ;i METHOD 4. 3 r ., RECEIPT # CHECK # `:, CLTD BY. R Total Paid for PERMIT ISSUANCE: $91.85 $0.00 Y ' TOTALS:i 0- ' Description: LORIA RESIDENCE /HVAC CHANGE OUT Type: MECHANICAL Subtype: Status: APPROVED Applied: 6/9/2016 MFA Approved: 6/9/2016 MFA Parcel No: 604452025. Site Address: 79664 MORNING GLORY CT LA QUINTA,CA 92253 Subdivision: TR 25691 Block: Lot: 33 Issued: . Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $16,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 CONTACTS Details: (2) HVAC CHANGE OUTS -14 SEERS/80AFUE SPLIT SYSTEM [2008 ENERGY] CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. PER 2013 CALIFORNIA BUILDING CODES. ADDITIONAL SITES Printed: Thursday, lune 09, 2016 11:35:09 AM . 1 of 2 SYSTEMS CONDITIONS CONTACTS NAME TYPE &'NA ME 'ADDRE551 ` ~ CITY, "` ' STATE' E;> ZIP hPHONE.' FAX EMAIL APPLICANT IE INC 31225 LA BAYA WESTLAKE. CA 91362 (760)464-5584 VILLAGE CONTRACTOR HARRISON ENTERPRISES INC DBA 31170 RESERVE DRIVE .THOUSAND CA 92276 (760)464-5584 FRANCISCO@CALLTHE GENERAL AIR PALMS GENERAL.COM OWNER STEVEN LORIA 79664 MORNING LA QUINTA CA' 92253 (760)464-5584 GLORY CT Printed: Thursday, lune 09, 2016 11:35:09 AM . 1 of 2 SYSTEMS PARENT PROJECTS Printed: Thursday, June 09, 2016 11:35:09 AM 2of2 �.. 9.IF, 4- w, CLTD' DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT CHECK# METHOD PAID BY BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $0.00 . BSA: HVAC CHANGEOUT - 101-0000-42402 0 $145.04 $0.00 SPLIT -SYSTEM. HVAC CHANGEOUT - 101-0000-42600 0 $72.52 $0.00 SPLIT -SYSTEM PC Total Paid for CHANGEOUT: $217.56 $0.00 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:• i0 PARENT PROJECTS Printed: Thursday, June 09, 2016 11:35:09 AM 2of2 �.. 9.IF, Bin # Clty. of La Qurnta Building ar Safety Division P.O. Box 1504,78-495 Calle Tampico L..Qulnta, CA 92253 -:(760) 777-7012 Building Permit Application and Tracking Sheet Permit # v Project Address: 79664 Morning Glory Court Owner's Name:. Steven Loria A. P. Number. Address: 79664 Morning Glory Court Legal Description: r. General Air Conditioningta;=' Contractor City, ST, Zip: La Quinta, CA 92253 RIM Telephone: 760-464-5584 ~ �Y;'���m::v.�; Address: 31170 Reserve Drive Project Description: Replace Ston A/C,'Coil, & 70,000 BTU . City, ST, Zip: Thousand Palms, CA 92276 Furnace Telephone: 760-343-7488"' Replace 2.5ton A/C, Coil, & 70,000 BTU Furnace State Lic. # : 686310 City Lie',#; Engr., Designer [Arch., Address: City, ST, Zip: Telephone:. .:f` State Lie. #: � � �%:��...3��y%� Name of Contact Person: Steven Schnierer Construction type: Occupancy: project type (circle one): New Add'n Alter Repair Demo Sq. Ft.: #Stories: #Units: Telephone # of Contact Person: 8.18-735-7876 sProject $16,000,00. APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cales. Reviewed, ready for corrections Plan Check Deposit. . Taus Cates. Called Contact Person Plan Check Balance Title 24 Calci. Pians picked up Construction Flood plain plan Plans resubmitted_'. Mechanical Grading plan 2`d Review, ready for correctionslissue Electrical Subcontactor IAst Called Contact Person Plumbing ` Grant Deed Plans picked up SMI, H.O.A. Approval Plans resubmitted' Grading 1]H HOUSE:- ''d Review', ready for correctionslissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees CERTIFICATE OF COMPLIANCE Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) Project Name: STEVEN LORIA I Date Prepared: CF1R-ALT-02-E (Page 1 of 3 2016-06-06 A. General Information MR -ALT -02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one MR -ALT -02 document for each dwelling unit. 01 Project Name STEVEN LORIA 02 Date Prepared 2016-06-06 03 Project Location 79664 MORNING GLORY COURT 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name STEVEN LORIA 07 Zip Code 92253 08 Dwelling Unit Conditioned 2237 -* *Installingrnew SC N Installing rte, Instalhngr installing Floor Area (ft2) Identification or Location or Area by this SC ducted containing Number of space conditioning more than 40 09 Climate Zone 15 10 (SC) systems in this dwelling 2 system?. component? components? feet of ducts? unit. SC system? B. Space Conditioning (SC) System Information ... t 01 02 03 , .,. ,.Y 04 U5 i i D61 07\� U8 09 10 .FIs the SC: x IrisLall ng ate. ' '' �`.` ' WA `j �_.� k4 ' . t'- SC System SC System CFA served system•a� sr�. refrigerant t -* *Installingrnew SC N Installing rte, Instalhngr installing Identification or Location or Area by this SC ducted containing system more than 40 entirely e v entirely new Name Served System (ft2) system?. component? components? feet of ducts? duct system? SC system? Alteration Type System 1 Location 1 1118 Yes Yes Yes No No No Altered space conditioning system System 2 Location 2 1118 Yes Yes Yes No No No Altered space conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section1S0.2(b)iDiib) This section does not apply to this project. Registration Number: 216-A0208711A-000000000-0000 Registration Date/Time: 2016-06-06 20:30:09 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.007 Report Generated: 2016-06-06 20:29:30 Schema Version: 0.5555DD CERTIFICATE OF COMPLIANCE CFiR-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 2 of 3) D. Altered Space Conditioning System (Sections 150.2(b)1E and F) 01 02 03 04 05 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency. Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R -Value Central gas All new Central split All new This field or This field or System 1 furnace heating AFUE 78 AC cooling SEER 14 Setback section is not section is not components components applicable applicable All new All new This field or This field or System 2 Central gas heating AFUE 7g Central split cooling SEER 14 Setback section is not section is not furnace components AC components applicable applicable Reouired Documentation: CF2R-MCH-01-E - Space Conditioning Systems Ducts and Fans `E -Duct insulation requirement for new plenums: R6. -- . -:• CF2R-MCH-20-H & MR -MCH -20-H — Duct Leakage testing required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced. -Leakage rate compliance: 515%, or15 10% leakage to outside, or seal all accessible leaks. CF2R-MCH-25-H & CF3R-MCH-25-H Refrigerant Charge Verification required when refngeraant�containing components are ihstalled:or altered;(applicable in CZ 2; 8-15). ., CF2RCF3R-MCH-23 & MR -MCH -23 Air Flow 2 300 CFM/ton required when MCH 25 is requlred' f Exceptions: CIO -Duct systems registered with HERS provider as previously sealed are exempt from MCH;20 Duct Leakaged_(�"Testing requirements 1,441 * •+ a -Heating-only systems and Air Handler/Furnace changes do not reclWre.verification of Air Flow MCH -23 or Refrigerant Charge MECH-25. guir Existing duct systems constructed, insulated or sealed with asbestos are exempt from<4f ?,0 Duct eakage.xTesting requirements. E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)iDiia and 150.2(b)1E, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) This section does not apply to this project. Registration Number: 216-A0208711A-000000000-0000 Registration Date/Tirne: 2016-06-06 20:30:09 HERS Provider: CalCERTS CA Building Energy Efficiency Standards.- 2013 Residential Compliance Report Version: 2013 Rev 1.007 ReportGenerated: 2016-06-06 20:29:30 Schema Version`. 0.555SDD CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 3 of 3 ) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Shanley, Barbara O Company: Signature Date: HARRISON ENTERPRISES INC dba GENERAL AIR CONDITIONING 2016-06-06 20:30:09 Address: CEA/ HERS Certification Identification (if applicable): 31-170 RESERVE DRIVE STE A City/State/Zip: Phone: THOUSAND PALMS CA 92276 760-343-7488 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on.this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code ofR egulat on 1 ^� ". 4. The building design features or system design features identified on this Certificate of Compliance are consistent -.with the information provided on other;applicatSle compliance documents, worksheets, e* s q calculations, plans and specifications submitted to the enforcement agency Torr approval with this building permit app licatio n. . of 5. 1 will ensure that a registered copy of this Certificate of,Compliance shall be;made,available with the building permit(s)issued fonthe building, andmade available to tfi nforcement agency for all applicable inspections. I understand that a registered copy of this Certiificate of Compliance is�required to be.included with the.documentaation the builder providesrto_the building owner at occupancy. lz Responsible Designer Name: ..»- Responsible Designer Signature: . Shanley, Barbara Company: Date Signed: HARRISON ENTERPRISES INC dba GENERAL AIR CONDITIONING 2016-06-06 20:30:09 Address: License: 31-170 RESERVE DRIVE STE A 686310 City/State/Zip: Phone: THOUSAND PALMS CA 92276 760-343-7488 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-AO208711A-000000000-0000 Registration Date/Time: 2016-06-06 20:30:09 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.007 Report Generated: 2016-06-06 20:29:30 Schema Version: 0.555SDD