Loading...
BSOL2015-0034- , j tllftr(ai 78-495 CAL LE TAMPICO LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT VOICE (760).777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/4/2015 Application Number: BSOL2015-0034 Owner: Property Address: 79813 MORRIS AVE , DWIGHT HARMON APN: 604511012. .79813 MORRIS Application Description: HARTMON /4.4kW PV SYSTEM - (16) 28OW PANELS/(1) INVERTER LA QUINTA, CA 92253 Property Zoning: . Application Valuation: $28,000.00 Applicant: D Lrti Contractor: UNITED FIELD REMODELING INC DB UNITED FIELD. REMODELING INC DB .17855 VANOWEN STREET MAY 0 4 2015 17855 VANOWEN STREET RESEDA, CA 91335 RESEDA, CA 91335 • CITY OF LAQUINTA COMMUNITYDEVELOPMENTDEPARTMENT (818)402-5656 Llc. No.: 896912 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 896912 JkDate: ^0Contractor: 1 OWNER -BUILDER DEC RATION I hereby affirm under penalty of perjury that•I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement.that he or she is licensed pursuant to the provisions of the Contractor's State License law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: - ( ) I, as owner of the property, or my employees with wages as their sole . compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (� I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts. for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: 'CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ..C-). Lender's Name:_ Lender's Addres< WORKER'S.COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of thew for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy.number are: Carrier: _ Polity Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation. laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000).. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application ,,the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of . work for 180 days will subject permit to cancellation. ' I certify that I have read this application and state that the above information is correct.. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned property for inspection purposes. Date: - 6 I Signature (Applicant or Agent): FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forBUILDING STANDARDS ADMINISTRATION BSA: $2.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 101-0000-42403 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for ELECTRICAL: $48.34 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85. $0.00 PAID BY MET -HOD RECEIPT # CHECK # CLTD BY a Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:00 Al Description: HARTMON /4.4kW PV SYSTEM - (16) 280W PANELS/(1) INVERTER . Type: SOLAR Subtype: Status: APPROVED Applied: 3/27/2015 SKH Approved: Parcel No: 604511012 Site Address: 79813 MORRIS AVE LA QUINTA,CA 92253 Subdivision: TR 24197-4 Block: Lot: 19 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: CONDITIONS' Finaled: Valuation: $28,000.00 } . , " Occupancy Type: ' Construction Type: Expired: No Buildings: 0 R +. t No. Stories: 0T. r y No. Unites:'0 r Details: 4.4kW SOLAR ARRAY - (16) 280W SUNMODULE PANELS W/ (1) POWERONE PVI -5000 -TL -A INVERTER [2885F] 2013 CALIFORNIA'-..-.. ELECTRICAL CODE. i 1 �..3r1 .dr r i i 1 j a CONDITIONS' CONTACTS €NAME TYPE NAME - ADDRESSI CITY STATE ZIP PHONE FAX EMAIL i APPLICANT -UNITED FIELD REMODELING INC.DB 17855 VANOWEN RESEDA CA 91335 '(760)772-9689 j STREET _ _. - 1 ~ _ _� Y _ _. �• CONTRACTOR _ s, .. : ► UNITED FIELD REMODELING INC DB .. ..+ .._a ....+a r i 17855 VANOWEN , STREET. RESEDA. CA :15 91335 - I ��... (760)772-9689 - .l:�,c 1 .'� YT: t'+ t _ ►_y... i':'''.7:t I • �:Prtinted: Monday, Y Ma 04, 2015 4:12:56 PM }� ' 1 of 3 roti St:-yi:.,.• C.�u., �; _ .,.TCMS Description: HARTMON /4.4kW PV SYSTEM - (16) 280W PANELS/(1) INVERTER .. ADDITIONAL SITES- Type: SOLAR Subtype: • Status: APPROVED Applied: 3/27/2015 SKH Approved: Parcel No: 604511012 Site Address: 79813 MORRIS AVE LA QUINTA,CA 92253 Subdivision: TR 24197-4 Block: Lot: 19 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 • Zoning: Finaled: Valuation: $28,000.00 " Occupancy Type: _ ^ . Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 i Details: 4.4kW SOLAR ARRAY - (16) 280W SUNMODULE PANELS W/ (1) POWERONE PVI -5000 -TL -A INVERTER [2885F] 2013 CALIFORNIA ELECTRICAL CODE. - C . Printed: Monday, May 04, 2015 4:12:56 PM 1 of 3 ' - - SYSTEMS ADDITIONAL SITES- CHRONOLOGY , ,ren.. it.f .� s. �N+: OTaS NAME +ah2ar._- :* "---. .�+ari..f�c »a.,.,:?�o:�-: H.3Rn..O,�-'.N::: OwAL_O..iG• Y.''Tt YoPv.E. ACTION DATE �S;rv"xTe.A-cF<+.F--�.,n.r. ^^. ;ACr �y---a•�b ?.. t.s° xTS:—. _ _ u: 4 hw .+f. .`.-'." �t= tea�.r nh?e+i3' is .l<YC.+>O....M=+6 PT, •. ,t '��` »7a y. c...=#.;z. t! • .1'i ..4 ^-'� r. °7'A-e.i"3f i;i °. r EMAIL SENT TO CONTACT [ENVER ; E-MAIL AJ ORTEGA 4/15/2015 4/15/2015 (CELLO_76@HOTMAIL.COM)] WITH 1ST REVIEW COMMENTS i AND REDLINES ATTACHED. LEFT MESSAGE FOR ENVER (562-396-1728) THAT COMMENTS TELEPHONE CALL AJ ORTEGA 4/13/2015 H 4/13/2015 ARE AVAILABLE TO BE PICKED UP, REDLINES AND CORRECTION LIST ATTACHED. CONDITIONS • NAME=TYPE`S'' NAME _ $.-'x ADDRES51 4�CITYr°= +� -STATE': °tIP-`PH ON %' "_ £"�° 0 EMAIL ,- >: .APPLICANT -UNITED FIELD REMODELING INC.DB 17855 VANOWEN RESEDA CA 91335 (760)772-9689 - STREET CONTRACTOR UNITED FIELD REMODELING INC DB 17855 VANOWEN RESEDA • CA 91335 - (760)772-9689 STREET Printed: Monday, May 04, 2015 4:12:56 PM 1 of 3 ' - - SYSTEMS Printed: Monday, May 04, 2015 4:12:56 PM 2 of 3 SYSTEAAS FINANCIAL • ' • SOLAR FINAL"* BLD LTD CBY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY REVIEW TYPE REVIEWER SENT DATE BY BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 NON-STRUCTURAL Total Paid for BUILDING STANDARDS ADMINISTRATION $2.00 $0.00 4/13/2015 BSA: LEFT MESSAGE FOR ENVER (562-396-1728) THAT COMMENTS ARE AVAILABLE TO BE PICKED UP, .REDLINES AND CORRECTION LIST ATTACHED. PV SYSTEM - ARRAY, 101-0000-42403 0 $24.17 $0.00 FI RST 2U PV SYSTEM-J4RRAY, 101-0000-42600 0 $24.17 $0.00 FIRST 20 PC Total Paid for ELECTRICAL: $48.34 $0.00 PERMIT ISSUANCE 101-0000-42404 1 0 J $91.85 $0.00 Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:$0.00 Printed: Monday, May 04, 2015 4:12:56 PM 2 of 3 SYSTEAAS INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED DATE DATE RESULT REMARKS NOTES SOLAR FINAL"* BLD Printed: Monday, May 04, 2015 4:12:56 PM 2 of 3 SYSTEAAS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES NON-STRUCTURAL AJ ORTEGA 3/27/2015 4/10/2015 4/13/2015 REVISIONS REQUIRED LEFT MESSAGE FOR ENVER (562-396-1728) THAT COMMENTS ARE AVAILABLE TO BE PICKED UP, .REDLINES AND CORRECTION LIST ATTACHED. Printed: Monday, May 04, 2015 4:12:56 PM 2 of 3 SYSTEAAS I NON-STRUCTURAL I AJ ORTEGA 14/28/2015 I 5/5/2015 I: 5/4/2015 I APPROVED F Bin # Permit # I S City of.' .Quinta Building &r.Safety Division P.O. Box 1504, 78-495 Calle Tampico La QuinraCA 92253 - (760) 777-7012. Building Permit Application and Tracking Sheet Project Address: 13 1v p, ' S v ' Owner's Name: A. P. Number: 60 ,) 01 Address: q e? is o(> A� V � Legal Description: V So )— r2 • City, ST, Zip: ,2 � • �o C) Contractor: q CJ tY e ' 0 Tele telephone: P o e. q . ....................... Address: �jss' U�rJ v eN Project Description: City, ST, Zip: pe SPp 14 CA q, 1,S v i�U • SJ R PP0 F A1 P ele h f{ Telephone: Po . tl �� Q� O li V :#:.;;:<> Pt o ' 14 S. S "! .g � e � State Lic. # : G 2 City Arch., Engr., Designer: Address: City., ST, Zip: Telephone: hone: Co n tructi n T. s o e: ccu Type: Occupancy: P Y: State Lic. #: Pro e ct hPa (circle le one : New Add'n Alter Repair Demo Name of Contact Person: fvveqSq. Ft:: # Stories: # Units: Telephone # of Contact Person: — % 6 — J.1g Estimated Value of Project: � � oo APPLICANT: DO NOT WRITE BELOW THIS LINE H Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE: '"' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees COMMUNITY DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO jLA,,QUpNTA, CALIFORNIA 92253. (760) 777-7125 FAX (760) 7.77-7011 RESIDENTIAL PLAN CHECK CORRECTION LIST (SOLAR) DATE: APRILl 0, 2015 `STATUS: FIRST REVIEW PLAN CHECKEFBY: AJ ORTEG rA TELEPHONE NUMBER- (Z60) 77.77018 ADDRESS: 79-813 MORRIS AVE DESCRIPTION: PV SOLAR SYSTEM APPLICANT: UNITED FIELD REMODELING PLAN CHECK #: BSOL2015-0034 This submittal has been checked for compliance with the 2013 California Building Codes and the City of La Quinta Municipal Code. APPLICANT: The following items are being returned to you for correction: 1- SOLAR (REDLINED) PLAN 2- UNMARKED PLAN SET 2- STRUCTURAL CALCULATIONS 1- CORRECTION LIST BUILDING DEPARTMENT STAFF: DO NOT accept any resubmittal unless ALL of the following items are included: 1 -SOLAR (REDLINED) PLAN 1- CORRECTION LIST w/responses 2- REVISED PLAN SETS 2- STRUCTURAL CALCULATIONS 1- ASSESSORS SITE/FLOOR PLAN INSTRUCTIONS TO APPLICANT: 1) Provide a written response to each comment on the following:pages, noting specifically where the correction can be found. Responses such as, "Sheet A-3," or; "Handrails shall be per CBC Section 1003," are not acceptable. Show or note specifically how compliance with anode requirement.is achieved. Responses such as, "Added note 16. on sheet A-3" are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or Calculations as necessary. 3) Return all red -marked Plans and/or Calculations with your resubmittal 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear.his/her stamp as prescribed by California Business and Professions Code Section 5536. Resubinittals will not be accepted with signatures missing. 5) Return this list, your written- responses, and all documents listed above with your resubmittal. Residential Plan Check Correction List (SOLAR) Page 1 of 3 SECTION A - GENERAL 1) Provide a Sheet Index, Vicinity Map (with no6th,&.row covering at least a two -block area), and a Complete Legal Description on the first sheet of Plans. 2) Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations -the preparer's name and telephone number and wet -signature. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and - Professions Code '5536. Resubmittals will not be accepted with signatures missing. SECTION B — SOLAR I. General 1) Reconcile noted information shown on single line diagram. See 1" review redlined plan. Please provide a response for each item, either on returned redlined plan or in letter. 2) Note on Plans: "Photovoltaic system conductors shall be identified and grouped. The means of identification shall be permitted by separate color coding, marking tape, tagging, or other approved means. The means of grouping shall be wire ties or similar means at least once, and then at intervals not to exceed six (6) feet."_ (CEC §690.4(B)) 3) Note on Plans: "Photovoltaic equipment and systems and all associated wiring and interconnections shall be installed only by qualified persons." (CEC §690.4(E)) H. Circuit Requirements 1) Circuit conductors shall be sized to carry the large of 125% of the maximum currents calculated in 690.8(A) without any additional correction factors for conditions of use or 100% of the maximum current after conditions of use have been applied. (CEC §690.8(B)(1)) The size of conductor specified on plan is not being shown as corrected accordingly. Please see redlined plan for required information to be shown on plan. III. Disconnecting Means 1) No corrections -apply. IV. Wiring Methods 1) Conduits exposed to sunlight on rooftops, where conductors or cables are installed, the adjustments shown in Table 310.15(B)(2)(c) shall be added to the outdoor temperature to determine the applicable ambient temperature for application of the correction factors in Table 310:16. (CEC §310.15(13)(2)(c)) See above comment, and adjust conductor sizes accordingly to the requirements for temperatures of 114-122°F. V. Grounding 1) No corrections apply. VI. Marking, Connection to Other Sources, Storage Batteries and Systems Over 600 Volts 1) Provide schedule with the location of all required markings and labels for the proposed photovoltaic system. (CEC §690) Please update signage sheet per redlined comments. Residential Plan Check Correction List (SOLAR) Page 2 of 3 'City of La Quinta '2) PV power source bonductors installed within exposed raceways, cable trays; and other wiring methods, covers or enclosures of pull boxes and junction boxes, and conduit bodies in which any of the'available conduit openings are used; shall be marked with the following wording 'Photovoltaic Power Source" by means of permanently affixed labels -spaced not more than ten (10) feet between labels. (CEC §690.31(D)(3)) SECTION C - FIRE 1) Marking is required on.interior-and exterior direct=current (DC) conduit, enclosures, raceways, cable assemblies, junction boxes; combiner.'boxes and disconnects: Demonstrate compliance with the following information on plan: a) Materials used for marking shall be reflective, ,weather resistant and suitable for the environment, be of all capitalized letterswith.a.riminimum height. of 3/8: inch (9.5 mm) white on red background. b) Marking shall contain the words "WARNING: PHOTOVOLTAIC POWER SOURCE." c) Conduits shall be specifically marked every 10 feet (3048 mm), within 1 foot :(305 mm). of turns or bends and within 1 foot.(305 mm) above and below penetrations of roof/ceiling assemblies, walls or barriers.' SECTION D -STRUCTURAL 1.) No corrections apply. SECTION E - MISCELLANEOUS COMMENTS 1) Red marks on Plans, even ifnot specifically mentioned in this list, indicate items needing correction. Revise Plans as necessary and provide written response, rioting where correction can be found. 2) Provide one.copy each of.the Site Plan and Floor Plan for the County A§sessor's.office. While.not required - for resubmittal, this administrative item must be addressed prior to issuance of building permit. END CORRECTION LIST As further information is provided and reviewed, additional corrections may be required. Residential Plan Check Correction List' Page 3 of 3