Loading...
BSOL2016-0116e' y 78-4,P5 CALLE TAMPICO LA.QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application Description Property Zoning: Application Valuation: Applicant: SUNTREK INDUSTRIES INC 5 HOLLAND #215 IRVINE, CA 92618 `sur 4 4QuiA DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT BSOL2016-0116 56310 MUIRFIELD VILLAGE 762390004 WILSON /SOLAR THERMAL WATER HEATING SYSTEM $17,000.00 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: RICH WILSON 56310 MUIRFIELD VILLAGE LA QUINTA, CA 92253 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000} of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C46 License No.: 859460 _ Date �Q '/ ' �` Contractor i OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: Date: 10/7/2016 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: GRANITE STATE INSURANCE COMPANY Policy Number: 1863590 _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date' - i0-7 - (j! Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon theme above-mentioned property for inspection purposes. ) Date: 0" - sr Signature (Applicant or Agent): Contractor: SUNTREK INDUSTRIES INC © 2030� HOLLAND #215 lrLT IRVINE, CA 92618 (949)348-9276 Llc. No.: 859460 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000} of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C46 License No.: 859460 _ Date �Q '/ ' �` Contractor i OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: Date: 10/7/2016 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: GRANITE STATE INSURANCE COMPANY Policy Number: 1863590 _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date' - i0-7 - (j! Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon theme above-mentioned property for inspection purposes. ) Date: 0" - sr Signature (Applicant or Agent): Dater 10/7/2016 Application Number: BSOL2016-0116 Owner: Property Address: 56310 MUIRFIELD VILLAGE RICH WILSON APN: 762390004 56310 MUIRFIELD VILLAGE Application Description: WILSON / SOLAR THERMAL WATER HEATING -SYSTEM LA QUINTA, CA 92253 Property Zoning: Application Valuation: $17,000.00 Applicant: Contractor: SUNTREK INDUSTRIES INC SUNTREK INDUSTRIES INC 5 HOLLAND #215 5 HOLLAND #215 IRVINE, CA 92618 IRVINE, CA 92618 (949)348-9276 Llc. No.: 859460 --------------------------------------------------------------------------------------------- Detail: SOLAR THERMAL DOMESTIC WATER HEATING SYSTEM WITH TANKLESS WATER HEATER CHANGEOUT AND 80GAL STORAGE TANK INSTALLATION [40SF] 2013 CALIFORNIA BUILDING CODES. 0 FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $91.85 Total Paid for PERMIT ISSUANCE: $91.85 DESCRIPTION ACCOUNT QTY AMOUNT SOLAR THERMAL 101-0000-42401 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT SOLAR THERMAL PC 101-0000-42600 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.67 Total Paid for PLUMBING FEES: $76.00 J in. Cit Of Quth �V' V. a ' 1 I Building 8t Safety Division t P.O. Box ! 504, -78-495 Calle Tampico Pe # �) La.Quinta, CA 92253 -:(760) 777-70]2 Buil " g Permit Application and Tracking Sheet eot Address: A 10 I Owner's Name:. I G o �✓ P. Number. Address: 563)0 Vt r 4 LeW Description: City, ST, Zip: L.4 A / uIN7lL _ Permit Fees I eiepnone: 7 YZ• LJ '- ' d Z.7 :>> k :s.... [Address'.�I U � vG, 2 I Project Description: l N 5 �/1�ity, ST, Zip: ' Rv" V L C` fi' CJ of g o iA!' Gcl:4 4--c. �G Telephone: qy?-3Yg_ a%�o° 4• '� �e/1 state Lic. # : ty Lie. #: oft GvC� 1-7-/t aZ Arch., Engr., Designer. � /�qe5 / � C i Address: 7j LS, bu r City, ST, Zip: --� �v 9�C 44k4 Telephone: �0 S - `7 �; - Z 1 U 0 State Lic. #:S -T YS CAL "313° Construction Type:. V Occupancy: R - .` Project type (circle one): New Add'nAlter. Repair Demo Name of Contact Person: (),4 N D NG Sq. Ft.: Ci # Stories: # Units: Telephone # of Contact Person: ep Uj �i � 3 ? G Estimated Value of Project: OQ D APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACMNG PERMIT FEES Plan Sets Pian Check submitted Item Amount S"ctufal Coles. Reviewed, ready for corrections Plan Check Deposit. . Truss Coles. Called Contact Person Plan Check Balance. Title 24 Calcs. Pians picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2id Review, ready for correctionslissue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up SALL H.O.A. Approval Plans resubmitted Grading IN IIOUSE:- '"' Review; ready for correedl issueeveloper lov, Impact Fee Planning Approval. Called Contact Person A.LP.P. Pub. Wks. Appr - Date of permit issue School Fees Permit Fees i SITE LOCATION m TRUE NORTH VICINITY MAP m TRUE NORTH WILSON RESIDENCE 56310 MUIRFIELD VILLAGE LA QUINTA, 92253 SOLAR HOT WATER SYSTEM TANKLESS GAS HOT WATER HEATING UNIT SCOPE OF WORK 1. THE DESIGN BUILD CONTRACTORS SHALL FURNISH AND INSTALL HOT WATER SOLAR HEATING SYSTEM, INCLUDING, BUT NOT LIMITED TO: SOLAR COLLECTORS, ASSOCIATED MANIFOLDS, SOLAR COLLECTOR CONNECTION HARDWARE, SOLAR COLLECTOR MOUNTING/INSTALLATION HARDWARE AND ALL APPURTENANCES. 3. FURNISH AND INSTALL ROOF SUPPORTS AND COLLECTOR ANCHORS. 4. FURNISH AND INSTALL PIPE FASTENERS, MOUNTING HARDWARE, AND RIGID PIPE CLAMPS FOR PIPING UP THE WALL. 5. INSTALLATION OF TANKLESS GAS WATER HEATER 6. REMOVAL OF EXISTING 40 GAL. GAS WATER HEATER STANDARDS ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE APPLICABLE EDITIONS OF ALL NATIONAL, STATE, AND LOCAL CODES, LAWS, REGULATIONS, AND ORDINANCES, INCLUDING THE FOLLOWING: AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) AMERICAN SOCIETY OF TESTING MATERIALS (ASTM) 2013 CALIFORNIA ELECTRICAL CODE (CEC) 2013 CALIFORNIA BUILDING, RESIDENTIAL, ELECTRICAL, PLUMBING ENERGY CODES WITH LOCAL AMENDMENTS 2013 GREEN CODE DELIVERY, STORAGE, AND INSTALLATION SHALL COMPLY WITH SPECIFICATION SECTION 13563. ALL PIPING SHALL BE 3/4' TYPE L COPPER, INSULATED. CARBON MONOXIDE ALARMS ARE REQUIRED TO BE INSTALLED IN EXISTING DWELLING UNITS OR SLEEPING UNITS WITH A FOSSIL FUEL BURNING HEATER OR APPLIANCE, FIREPLACE, ATTACHED GARAGE. CARBON MONOXIDE ALARM SHALL BE LOCATED IN EACH AREA GIVING ACCESS TO A SLEEPING ROOM AND ON EACH STORY DWELLINGS WITH MORE THAN ONE STORY CARBON MONOXIDE ALARMS ARE PERMITTED TO BE SOLELY BATTERY OPERATED WHERE NO CONSTRUCTION IS TAKING PLACE. CONSTRUCTION HOURS: Monday - Friday 7:00 a.m. - 5:30 p.m. Saturday 8:00 a.m. - 5:00 p.m. Sunday NOT ALLOWED Holidays NOT ALLOWED CITY OF LA QUINTA BUILDING & SAFETY DEPT. -� APPROVED FOR CONSTRUCTION 8Y A6,,IwG, Ac, SktsIrG- AA SHEETINDEX P-1 VICINITY MAP AND PROJECT LOCATION/ COVER PAGE P-2 SITE PLAN SHW-1 SYSTEM FLOW DIAGRAM SHW-2 MOUNTING SPECS SHW-3 RACK ATTACHMENT DETAIL SHW-4 COLLECTOR SPECS SHW-5 STORAGE TANK SPECS SHW-6 PIPE INSULATION SPECS & R -VALUE SWI -11-7 TANKLESS GAS HEATER SPEC OCCUPANCY GROUP: R-3 CONSTRUCTION TYPE: V/B SAFETY SIGNAGE PRESENT IN COMPLIANCE WITH CA BUILD. CODE TITLE 24 SEP 2 7 2016 CITY OF LA QUINTA COMMUNITY Y DEVELOPMENT S.-UNTREK Your Solar Energy Company SUNTREK INDUSTRIES 5 HOLLAND #215 IRVINE, CA 92618 C-46 LIC. #859460 (949) 348-9276 PROJECT SOLAR HOT WATER SYSTEM LOCATION Z LI J z U �Q t Lu } _ OjN wW U) Qa wIL z � W5 OO z C� _ _ 0 �a W � g� J OU) 69 U) J Y Z DESIGNER A. HILL COVER PAGE REVISIONS SHEET NO. P-1 i N W E STRUCTURAL ONLY WO CH & ASSOCIATES cSlruclural 6nyineers 175 E. WILBUR ROAD, SUITE 103 - THOUSAND OAKS, CA 91360 P - 805.496.2100 f - 805.496.2442 e - \Ancl@VinciSE.com 1, OCCUPANCY GROUP: R -3 NUMBER OF STORIES: 1 STORY SOLAR PANELS LOCATED ON CONCRETE TILE ROOF 2, COMPLY WITH ALL MANUFACTURERS LISTINGS AND INSTALLATION INSTRUCTIONS, GENERAL NOTES HOT WATER SYSTEM 1 1 - 48 x 120" SOLAR COLLECTOR 1 - 80 GALLON STORAGE IN GARAGE SOLAR HOT WATER HEATING SYSTEM PAGE DETAIL 1. SOLAR COLLECTOR SWH-4 A 2. ROOF MOUNT/CONNECTION DETAIL SWH-3 A 3. RACKING SWH-2 A 4. (N) GAS HOT WATER HEATER/POC SWH-1 A 5. SOLAR STORAGE TANK ON EXISTING WATER HEATER PLATFORM IN GARAGE SWH-5 A 6.2 COPPER 3/4" TYPE "L" INSULATED PIPES (in attic, IF possible) 7. (E) 120v OUTLET FOR WATER HEATER AND SOLAR CONTROL POWER A ROOF PLAN - POOL THERMAL/SOLAR HOT WATER SYSTEMS G SUNTREIC Your Soler Energy Company SUNTREK INDUSTRIES 5 HOLLAND #215 IRVINE, CA 92618 C-46 LIC. #859460 (949) 348-9276 PROJECT SOLAR HOT WATER SYSTEM LOCATION I`— z W z U F -Q W� >-_ >N W W � o� � Q W Wg Q� �LZ �~ zga0� O og w Q w In -i U' J_ O cn J Y Z H DESIGNER A. HILL SITE PLAN ROOF PLAN REVISIONS SHEET NO. P-2 NOTE; ALL PIPING TO BE 3 / 4 " COPPER ALL PIPING TO BE INSULATED EXISTING OUTLET 120V OUTLET SEE P-2 FOR LOCATION 1 g � I I II II AO PIPING RISER DIAGRAM 0 X O 0 O O A SHW-4 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY PIPING RISER DIAGRAM 1. SUNEARTH DIFFERENTIAL SOLAR CONTROL WITH RECIRCULATING FREEZE PROTECTION 2. RHEEM 80 GAL. SOLAR STORAGE TANK WITH HEAT EXCHANGER LOCATED IN GARAGE ON EXISTING WATER HEATER PLATFORM 3. SUNEARTH Ec4O SOLAR COLLECTORS 4. QUAD-FLO BYPASS VALVE OR 3 VALVE BYPASS 5 j HP GRUNDFOS CIRCULAR PUMP 6. T&P VALVE W/ DRAIN TO TERMINATE OUTSIDE, NO CLOSER THAN 6" AND NO HIGHER THAN 24" ABOVE GRADE 7. BRASS BALL VALVE FOR BLEEDING AIR AT START UP 8. SOLAR STORAGE TEMP SENSOR 9. (E) COLD WATER INLET 10. (E) HOT WATER OUTLET TO HOME 11. (N) TANKLESS GAS WATER HEATER (SWH-7, SWH-7.1) 12. EXPANSION TANK 13. PERSSURE GAUGE 14. THERMOSTATIC MIXING VALVE 15. STORAGE TANK SHALL BE STRAPPED TO THE STRUCTURE. PROVIDE 1.5" X 16GA STRAPS AT TOP AND BOTTOM THIRD OF TANK. 16. (E) 18" HIGH WATER HEATER PLATFORM. PROTECTED AWAY FROM VEHICLE TRAFFIC WITH 3"X 36" STEEL BOLLARD 17. (E) 1/2" GAS SUPPLY AND ISOLATION VALVE SUNTREK Your Solar Energy Company SUNTREK INDUSTRIES 5 HOLLAND #215 IRVINE, CA 92618 C46 LIC. #859460 (949) 348-9276 PROJECT SOLAR HOT WATER SYSTEM LOCATION Z W gz U �Q Lu �gJ IM N wW U) J 0 Q Q W � Z > UR :5>� O Z c� O = O cl Q U) CD 0 J_ O U) J Y Z DESIGNER A. HILL SYSTEM 1 FLOW DIAGRAM REVISIONS SHEET NO. SHW-1 SOLAR HOT WATER COLLECTOR — 3/8"DIA.x 1.5" BOLTED TO STRUCT. SUPPORT PLATE SEE STRUCTURAL DETAIL AND CALCS FOR SUPPORT, BY OTHERS (TYP. 6 STRUCTURAL ONLY VONCO & ASSOCIATES 175 E. WILBUR ROAD, SUITE 103 - THOUSAND AKS, CA 91360 P- 805.496.2100 f - 805.496.2442 e - Vin @VinclSE.com 1 - SUNEARTH EC40 SOLAR COLLECTOR Additional Notes: 1. Solar Collectors lay flat on roof NOT TO EXCEED 3" HIGHT FROM ROOF SURFACE. OR MAX BUILDING HEIGHT 2. Solar Collectors will not exceed maximum building height 3. All insulation exposed b sunlight shall be protected from UV radiation with Rustoleum protective enamel flat black paint 4. All piping on roof is to be secured to pressure treated sleepers, and sleepers shall be secured to the roof, via the listing of roofing material, or equalmethod that will not void the listing of the roofing material. C POOL - SOLAR COLLECTOR DEPICTION AND NOTES Max Building Height (18') STRL r --------- .......----"-----------------•--•-------------------- E STRUCTURAL NOTES: TRUSS CONSTRUCTION - 2" x 4 6 TRUSS SPACING - 24" C x C. TRUSS SPANS - 10' . ...........................................• ----..................t REFER TO MOUNTING DETAIL, THIS SHEET SUN EARTH FAST JACK SUPPORTS w/ FLASHING BOOT. SEAL w/ SICKAFLEX SEALANT OR EQUAL .gF=rTInN PI AN VIEW OSOLAR COLLECTOR MOUNTING DETAILS SCALE: NONE C SUNT_ REK Your Solar Energy Company SUNTREK INDUSTRIES 5 HOLLAND #215 IRVINE, CA 92618 C-46 LIC. #859460 (949)348-9276 PROJECT SOLAR HOT WATER SYSTEM LOCATION z D W z U WQ W� }_ j04 N W W F -- U) Q Q Wiz 0 Z c� O = O> 0Q J J_ O U) J Y Z DESIGNER A. HILL MOUNTING SPECS REVISIONS SHEET NO. SHW-2 ANODIZED ALUM. MOUNTING CLIP & 3/8° SS BOLT ASSEMBLY w/ LOCKWASHER & FLATWASHER SS SLIDING NUT SIDE VIEW ROOF FLASHING 1 5/8"x 1 5/8° ANODIZED ALUM. STRUT, w/ LSHNU-STRUTTLOTS CHANNEL SHORT SLOTS AND FASTENING CLIP 8" 5° 1'x5" ANODIZED ALUM. 1 5/8"x1 5/8'x7° STRUT MOUNTING POST ANODIZED ALUM. MOUNTING FOOT 3'x3/8" SS FLATWASHER LAG BOLT SET IN SEALANT TILE ROOF ROOF DECK ROOF RAFTER �c, D 441 xp. /31 17 ST TURP' 3 F OF CALF COLLECTOR ANCHOR DETAIL OSOLAR SCALE: NONE 9/26/16 SOLAR HOT WATER COLLECTOR — 3/8"DIA.x 1.5" BOLTED TO STRUCT. SUPPORT PLATE SEE STRUCTURAL DETAIL AND CALCS FOR SUPPORT, BY OTHERS (TYP. 6 STRUCTURAL ONLY VONCO & ASSOCIATES 175 E. WILBUR ROAD, SUITE 103 - THOUSAND AKS, CA 91360 P- 805.496.2100 f - 805.496.2442 e - Vin @VinclSE.com 1 - SUNEARTH EC40 SOLAR COLLECTOR Additional Notes: 1. Solar Collectors lay flat on roof NOT TO EXCEED 3" HIGHT FROM ROOF SURFACE. OR MAX BUILDING HEIGHT 2. Solar Collectors will not exceed maximum building height 3. All insulation exposed b sunlight shall be protected from UV radiation with Rustoleum protective enamel flat black paint 4. All piping on roof is to be secured to pressure treated sleepers, and sleepers shall be secured to the roof, via the listing of roofing material, or equalmethod that will not void the listing of the roofing material. C POOL - SOLAR COLLECTOR DEPICTION AND NOTES Max Building Height (18') STRL r --------- .......----"-----------------•--•-------------------- E STRUCTURAL NOTES: TRUSS CONSTRUCTION - 2" x 4 6 TRUSS SPACING - 24" C x C. TRUSS SPANS - 10' . ...........................................• ----..................t REFER TO MOUNTING DETAIL, THIS SHEET SUN EARTH FAST JACK SUPPORTS w/ FLASHING BOOT. SEAL w/ SICKAFLEX SEALANT OR EQUAL .gF=rTInN PI AN VIEW OSOLAR COLLECTOR MOUNTING DETAILS SCALE: NONE C SUNT_ REK Your Solar Energy Company SUNTREK INDUSTRIES 5 HOLLAND #215 IRVINE, CA 92618 C-46 LIC. #859460 (949)348-9276 PROJECT SOLAR HOT WATER SYSTEM LOCATION z D W z U WQ W� }_ j04 N W W F -- U) Q Q Wiz 0 Z c� O = O> 0Q J J_ O U) J Y Z DESIGNER A. HILL MOUNTING SPECS REVISIONS SHEET NO. SHW-2 INSTALLATION OF THE FASTJACK® FLASHABLE ROOF STANCHION 3/8" BOLT ® / 3/8" WASHER THREADED POST 5/16" LAG BOLT 5/16" WASHER I DRILL GUIDE I MACHINED BASE FASTJACK® flashable mount system includes a machined aluminum base with integrated drill guide, 1" aluminum threaded post and stainless steel hardware. The FJ Series patented (pat #6,360,491) design is engineered to provide structural attachment of modules when conventional roof flashings are required. FJ mounts are available in two sizes; the 4-1/4" FJ425 (for conventional metal flashings) and the 3" FJ -300 for Oatey® style (low profile) neoprene flashings. The FJ design allows all flashings to install flat on the roof decking. FJ's superior strength while using only one single lag bolt (included) results from having the bolt installed directly under the support post. The system has been laboratory tested to 1,200 pounds and along with it's integrated drill guide insures perfect connections every time. 3/16" DRILL RAFTER FASTJACK'*' INSTALLED PARTS DIAGRAM DRILLING THE PILOT HOLE Place the mount base of the over the location of the rafter. Align the 3/16" (drill guide) over the rafter center. While holding the base—Insert the bit through the guide and drill down approx 1" into the roof. DRILL BOLT HOLE l" THREADED BASE F REQUIRED TOOLS: FJ -300 SERIES /16" DRILL BIT AND POWER DRILL /2" SOCKET " PIPE PLIERS BOLTING INTO THE RAFTER Place the 5/16" lag bolt thru the washer and AF base. Insert the lag bolt Into the pilot hole made in the roof. Drive the lag bolt Into the rafter using a 1/2" socket and Impact wrench. 1/2" FJ -425 SERIES INSTALLING THE POST SUPPORT Screw the threaded post into the base and tighten with a pipe pliers. Install the flashing over the post and attach the module support using the 3/8" bolt and washer (included). ✓ROOF FLASHING i m TIGHTEN POST ® SUPPORT INTO BASE Page 9 COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2002: All information contained in this manual is property of Professional Solar Products (PSP). TILE TRAGI is a registered trademark for PSP and is covered under U.S. patent #5,746,029. FASTJACK® is a registered trademark for PSP and is covered under U.S. patent #6,360,491. Product Data Sheet Edition 3.4.2014 Sikatlex Construction Sealant SikaflexO Construction Sealant One -component, all purpose; .polyurethane sealant STRUCTURAL ONLY H4060 A ASSOCIATES C31rucfural6n yin eers 175 E. WILBUR ROAD, SUITE 103 - THOUSAND OAKS, CA 91360 P - 805.496.2100 f - 805.496.2442 a - Vincl@\/InclSE.com eSEALANT SPECS SUNTREK Your Solar Energy Company SUNTREK INDUSTRIES 5 HOLLAND #215 IRVINE, CA 92618 C-46 LIC. #859460 (949) 348-9276 PROJECT SOLAR HOT WATER SYSTEM LOCATION Z 0 W Z U F_Q U (D L >- Z O J � Ir w /'� N V i J F— Q WZ j U_ Er -- 5 O z06 Oz Oo� a ) L0 c� J Q U) J Y Z DESIGNER A. HILL RACK ATTACHMENT DETAIL REVISIONS SHEET NO. S H W-3 Description Sikaflex Construction Sealant is a moisture -cured, 1 -component, polyurethane -based, non -sag elastomeric sealant Meets Federal specification 7T -S -00230C, Type 11, Class A. Meets ASTM C-920; Type S, Grade NS, Class 35, use T, NT, -O, M; G, 1; Canadian stan- dard CAN/CGSB 19.13-MB7. Where to Use ■ Designed for all types of joints where maximum depth of sealant will not exceed 1/2 in. . Suitable for vertical or horizontal joints; readily placeable at 40'F (4"C)_ ■ Has marry applications as an elastic sealant between materials with dissimilar coef- ficients of expansion. . Ideal for. • Weatherproofing of joints between brickwork, blockwork, masonry, wood and con- crete or metal frames_ • Jotnts in vmlls, floors, balconies, around window or door frames_ • Expansion joints. • Roofing. Advantages . High elasticity - cures to a tough, durable, flexible consistent/ with exceptional cut and �- tear -resistance. . Stress relaxation- . Excellent adhesion - bonds to most oortstrucfion materials without a primer. ■ Excellent resistance to aging, weathering- . Non -staining. - ■ Urethane -based; suggested by EPA for radon reduction. L' . Paintobte with water-, oil- and rubber -based paints.. ■ Capable of ±35% joint movement Coverage 10.1 fl. oz. cartridge seats t2.2lineal ft of 112 x 1/4 in. joint. Packaging Disposable 10.1 fl. oz_, moisture -proof composite cartridges, 121case. Typical Data (Materia/ and curing conditions @ 731F (23°C) and 50% R.M) _ Shelf Life 12 months Storage Conditions Store at 40° -95'F.(4` -35-C). Condition material to 65°-753F (18'-241C) before using. Colors White, Limestone, Capitol Tan, Dark Bronze, A]uminum Gray VOC. 40 gll Application Temperature 40- to 100`F (4'-38"C) . Sealant should be installed when joint is at midrange of its anticipated movement. Service Range -40` to 170"F (40"47-C) Curing Rate Tack -free tinge: 3-6 hrs; to touch: 3hrs; Final cure: 4-7 days Shore A Hardness Meets ASTM C-920 Adhesion in Peel (ASTM C 794) Concrete: Meets ASTM C-920 Aluminum: Meats ASTM C-920 ? Glass: Meets ASTM C-920 Weathering Resistance Excellent f�if. 441 ® Chemical Resistance Good resistance to water; diluted acids, and diluted alkalises. 4 P. /31 17 Consult T chnical Service for specific data. �' How to Use PT TURP" �' Surface Preparation Clean all surfaces. Joint walls must be sound, clean, dry, frost - OF CAL free, and free of oil and grease and any other contaminants. Install bond breaker tape or backer rod to prevent bond at base J 1 of joint. 9/26/16 STRUCTURAL ONLY H4060 A ASSOCIATES C31rucfural6n yin eers 175 E. WILBUR ROAD, SUITE 103 - THOUSAND OAKS, CA 91360 P - 805.496.2100 f - 805.496.2442 a - Vincl@\/InclSE.com eSEALANT SPECS SUNTREK Your Solar Energy Company SUNTREK INDUSTRIES 5 HOLLAND #215 IRVINE, CA 92618 C-46 LIC. #859460 (949) 348-9276 PROJECT SOLAR HOT WATER SYSTEM LOCATION Z 0 W Z U F_Q U (D L >- Z O J � Ir w /'� N V i J F— Q WZ j U_ Er -- 5 O z06 Oz Oo� a ) L0 c� J Q U) J Y Z DESIGNER A. HILL RACK ATTACHMENT DETAIL REVISIONS SHEET NO. S H W-3 THI EMPIRE SERIES IPL. Models EEC and EPSPECIF f�UH[HHTH AT ONSHEET THE VALUE LEADER IN SOLARWATER HEATING TECHNOLOGY StalnlessSteel Fasteners Riveted Corners • BlackChome or ModeratelySelective Black Paint AbsorberCoating • Copper AbsorberPlate • Type M Copper Riser Tubes and Manifolds • EPDM Grommets • 15% Silver Brazed Joints Low Iron Tempered Glass Low-BlnderFiberglass Insulation Rigid Foam Insulation Secondey Silicone Glazing Seal Integral Mounting Channel ExtrudedAnodized AluminumCasingand Capstrip Vent Plugs \ W Primary EPDMGlazingSeal Aluminum Backsheet MORTHI01. EMPIRE SERIES SPECIFICATIONS DP THERMAL PERFORMANCE RATINGS` MODELEP A -Pool Heating (warm Climate) B -Pool Heating CYJater Heating (warm Climate) DLtrater Heating (Cool Climate) E -Air Condilloning/Industrial RocessHeat Thermal performance Is obtained by multiplying the Collector output for the appropriate application and Insolation level by 2. total gross Collector ores. Collector ratings are derived from the Solar Rating 6 Certication Corp (SRCCpocument RM -1 and Standard OG100. ENGINEERING SPECIFICATIONS (Perrmmancaspacications subject to testing error of H- 3%) The following shall be the specicallons for the solar collectors. Collectors shall be SunFarthEmpire model Eo4o .and shall be of the glazed liq- uid at plate type. Collectorsshall be tested in conformancewith ASHRAW 1986 and SRCCI00$1.The collectors shall be certied by the Solar Rafing and Certkation Corporation (SRCCond the Florida Solar Energy Center (FSEC) GENERAL The dimensions of the collector shall be 122 inches in length, 48 inches in width and 3 114 Inches in depth. The collector casing shall be en anodized aluminum extrusion (alloy 6063 T5), minimum thick- ness .060 inch, with an architectural dark bronze nish. The rasing shall have notched framewalis for ease of plate removal and reinstallation. Sheet metal screwed fasteners shall be stainless steel (18-8 B10). The backsheet shag be textured aluminum not less than .014 inch thickness.A 1 inch vent plug shall be installed in each of the four comers of the backsheet to min- imize condensation. GLAZING The collector glazing shall be one sheet of low Iron tempered glass, with a minimum of 118 Inch thickness (5/32 Inch on EC/EP40), and a mink mum transmissivityof 91 percent (89 on EC/EP40). The glazing shall be thermally isolated from the rasing by a continuous EPDM gasket. There shall be a continuous secondary silicone seal between the glass and cas ing capstrip to minimize moisture from entering the casing INSULATION thermal isolation of the foam from the absorber plate. Total thermal resis- tance shall be a minimum of R-12. The sides and ends of the collector shall be insulated with a minimum of 1 inch foil -faced polyisocyanurate foam sheathing board. ABSORBER PLATE AND PIPING The absorber shall consist of a roll formed copper plate of no less than .008 inch thickness. Risersshall be a minimum of 1/2 inch O.D. Type M copper tubing on no more than 4 112 inch centers continuously soldered to the plate utilizing a non -corrosive solder paste with a matting point of 466 The risers shall be brazed to 1 118 inch 0. D. Type M (1 5/8 inch O.D. on ECIEP40.1.5} upper manifolds utilizing a copper phosphorous brazing alloy with no less than 15 percent silver content, and conforming to the American Ulding Society. BUP-5classication. EPDMgmmmets shall iso- late the manifold from the aluminum casing. The absorber plate shall be designed for 160 psig maximum operating pressue. ABSORBER COATING AND PERFORMANCE CURVE A) Black Chrome (EC Seras):The absorber coating shall be black chrome o nickel with a minimum absorptWily, of 95 percent and a maximum emissivit of 12 percent. The instantaneous a ciency of the collector shall be a mini mum xnteroept of 0.714 and a slope of no less then 0.7271(BTUH1--Ir)/F B) Moderately Selective Black Paint (EPSeries):The absorber coating shall be a moderately -selective black paint with a minimum absorptivity of 94 per - The insulation shall be foil -faced polyisocyanurate foam sheathing board of cent and a maximum emissivity of 56 percent. The instantaneous a ciency a minimum 1 incl thickness,siliconed in place to the aluminum backsheet, of the collector shall have a minimum Xintercept of 0.682 and a slope covered by low -binder be rglass of a minimum 1 inch thickness, providing no less than -0.7995 (BTU/fi )ue to SunEarth'spolicy of continuous product Improvement, specications are subject to change without notice. WNUACTUREE9y. WAILABLEFROAI: SUUEHHIUIL 8425 Abed. Ayepa - Fab., rA =5 pf"" (808)434-3100 • Fex(M)434J101 {.4�`V� www.sunearthinc.Ccrm RECYCLED PAPEK-50Y USED INKYy / �SWH SYSTEM SYSTEM COLLECTOR SPECS m cn T N FOR SUNTREOD K Your Solar Energy Company SUNTREK INDUSTRIES 5 HOLLAND #215 IRVINE, CA 92618 C-46 LIC. #859460 (949)348-9276 PROJECT SOLAR HOT WATER SYSTEM LOCATION I - Z r� V W Z � U F_Q Z LU co Lu W a >" _ N W W Cn o �- a w LL Z j �j= F -O Z 2 cY O z O o g r< U) In V J_ O U) J Y Z DESIGNER A. HILL COLLECTOR SPEC SHEET REVISIONS SHEET NO, SHW-4 Btufft /Day Cetegay (Ti -Ta) 11- INat up mms Tn- =UM Do- CLEAR DAY 2000 SIU/t2/Day MILCLY CLOUDYDAY 150D Btu/n2/Day CLOUDY DAY 1000 Btu/R2/Day A( -!?F) 1,284 971 659 8(9°F) 1,169 854 542 C(36•F) 884 677 372 D(9t F) 619 343 89 Ell F) 280 62 A -Pool Heating (warm Climate) B -Pool Heating CYJater Heating (warm Climate) DLtrater Heating (Cool Climate) E -Air Condilloning/Industrial RocessHeat Thermal performance Is obtained by multiplying the Collector output for the appropriate application and Insolation level by 2. total gross Collector ores. Collector ratings are derived from the Solar Rating 6 Certication Corp (SRCCpocument RM -1 and Standard OG100. ENGINEERING SPECIFICATIONS (Perrmmancaspacications subject to testing error of H- 3%) The following shall be the specicallons for the solar collectors. Collectors shall be SunFarthEmpire model Eo4o .and shall be of the glazed liq- uid at plate type. Collectorsshall be tested in conformancewith ASHRAW 1986 and SRCCI00$1.The collectors shall be certied by the Solar Rafing and Certkation Corporation (SRCCond the Florida Solar Energy Center (FSEC) GENERAL The dimensions of the collector shall be 122 inches in length, 48 inches in width and 3 114 Inches in depth. The collector casing shall be en anodized aluminum extrusion (alloy 6063 T5), minimum thick- ness .060 inch, with an architectural dark bronze nish. The rasing shall have notched framewalis for ease of plate removal and reinstallation. Sheet metal screwed fasteners shall be stainless steel (18-8 B10). The backsheet shag be textured aluminum not less than .014 inch thickness.A 1 inch vent plug shall be installed in each of the four comers of the backsheet to min- imize condensation. GLAZING The collector glazing shall be one sheet of low Iron tempered glass, with a minimum of 118 Inch thickness (5/32 Inch on EC/EP40), and a mink mum transmissivityof 91 percent (89 on EC/EP40). The glazing shall be thermally isolated from the rasing by a continuous EPDM gasket. There shall be a continuous secondary silicone seal between the glass and cas ing capstrip to minimize moisture from entering the casing INSULATION thermal isolation of the foam from the absorber plate. Total thermal resis- tance shall be a minimum of R-12. The sides and ends of the collector shall be insulated with a minimum of 1 inch foil -faced polyisocyanurate foam sheathing board. ABSORBER PLATE AND PIPING The absorber shall consist of a roll formed copper plate of no less than .008 inch thickness. Risersshall be a minimum of 1/2 inch O.D. Type M copper tubing on no more than 4 112 inch centers continuously soldered to the plate utilizing a non -corrosive solder paste with a matting point of 466 The risers shall be brazed to 1 118 inch 0. D. Type M (1 5/8 inch O.D. on ECIEP40.1.5} upper manifolds utilizing a copper phosphorous brazing alloy with no less than 15 percent silver content, and conforming to the American Ulding Society. BUP-5classication. EPDMgmmmets shall iso- late the manifold from the aluminum casing. The absorber plate shall be designed for 160 psig maximum operating pressue. ABSORBER COATING AND PERFORMANCE CURVE A) Black Chrome (EC Seras):The absorber coating shall be black chrome o nickel with a minimum absorptWily, of 95 percent and a maximum emissivit of 12 percent. The instantaneous a ciency of the collector shall be a mini mum xnteroept of 0.714 and a slope of no less then 0.7271(BTUH1--Ir)/F B) Moderately Selective Black Paint (EPSeries):The absorber coating shall be a moderately -selective black paint with a minimum absorptivity of 94 per - The insulation shall be foil -faced polyisocyanurate foam sheathing board of cent and a maximum emissivity of 56 percent. The instantaneous a ciency a minimum 1 incl thickness,siliconed in place to the aluminum backsheet, of the collector shall have a minimum Xintercept of 0.682 and a slope covered by low -binder be rglass of a minimum 1 inch thickness, providing no less than -0.7995 (BTU/fi )ue to SunEarth'spolicy of continuous product Improvement, specications are subject to change without notice. WNUACTUREE9y. WAILABLEFROAI: SUUEHHIUIL 8425 Abed. Ayepa - Fab., rA =5 pf"" (808)434-3100 • Fex(M)434J101 {.4�`V� www.sunearthinc.Ccrm RECYCLED PAPEK-50Y USED INKYy / �SWH SYSTEM SYSTEM COLLECTOR SPECS m cn T N FOR SUNTREOD K Your Solar Energy Company SUNTREK INDUSTRIES 5 HOLLAND #215 IRVINE, CA 92618 C-46 LIC. #859460 (949)348-9276 PROJECT SOLAR HOT WATER SYSTEM LOCATION I - Z r� V W Z � U F_Q Z LU co Lu W a >" _ N W W Cn o �- a w LL Z j �j= F -O Z 2 cY O z O o g r< U) In V J_ O U) J Y Z DESIGNER A. HILL COLLECTOR SPEC SHEET REVISIONS SHEET NO, SHW-4 Solaraide HE Solar Heat Exchanger, Solar Tank, or Electric Storage Water Heater V :7 • • Available in 80 and 120 Gallon Models 6 -Year Limited Tank and Parts Warranty* • Brass drain valve • Choice of two models... storage tank or single element water heater • Temperature and pressure relief valve included • Collector feed and return fittings located at front of tank for convenient installation • Isolated tank design for better heat retention • High efficiency heating element • Rheemglas® tank lining resists corrosion and prolongs tank life • Heat exchanger: copper tubing wrapped around and secured to the tank. Double wall, vented design for positive leak detection • Cold water inlet brings cold water to tank bottom to prevent mixing with heated water • Anode rod equalizes aggressive water action for prolonged tank life • Cold water inlet, hot water outlet, relief valve and anode rod at top of tank for easy access and fast, economical installation • Automatic temperature control • Over temperature protector See Residential Warranty Information Brochure for complete warranty information. ®O gama Solaralde HE Tank Capacity INFORMATIONDESCRIPTION ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY APPROX. APPROX. HEIGHT DIAMETER SHIPWT. FA A B JLBS.) CTOR T ELEMENI Y GAL. WATTAGE E CAP. MODEL NUMBER UPPER 80 81V80HE-14500 W 58-3/4 24-1/2 222 R-17.3 Heaters furnished with standard 240 volt AC, single phase non -simultaneous wiring and 4500 watt heating element. • If heating elements of different wattages than those shown are demanded by zone requirements, they must be specifically requested. • To prevent corrosion, proper pH levels in transfer fluid must be maintained. 1.3 1.6 • Solaraide models meet all current state requirements for solar storage tanks. 4.8 5.7 • The tanks are Rheemglas lined and are designed to operate up to 150 PSI. 10.0 12.0 A special 1/2" NPT opening is provided for installation of a "probe type" thermostat. :`: ; ; I IAF 0I - -- -o 0 — --- NOT AS COLD �� COPPER COIL DATA (Type L Copper) Maximum pressure = 150 PSI WATER CONNECTION NIPPLES ALL 3/4" N.P.T. Maximum temperature = 185° F Tube I.D. = 5/8" COLD NOT ; ; INLET Solaralde HE Tank Capacity Coll Capacity Length of Tubing Gallons Around Tank Ft 80 Gallons 2.2 120 120 Gallons 2.6 143 PRESSURE DROP THROUGH COIL (Feet of H,0) Flow Rate Head Loss (Feet) 80 Gallon 120 Gallon 1 GPM 1.3 1.6 2 GPM 4.8 5.7 3 GPM 10.0 12.0 OUTLET , , " COLLECTOR kNSOP A ' ' RETURN*0 V6011,Q��aVR2 COLLECTOR MSN FEED o -- 0 WATER CIRCULATOR (OPTIONAL FOR NOW GRANT Y SYSTEMS) In keeping with its policy of continuousprogress..improvement,. . Rheem Water Heating • 101 Bell Road, Montgomery, Alabama 36117 • www.rheem.com PRINTED IN U.S.A 06106 WP FORM NO. 101-16 Rev. 12 R SUN,, TREK Your Solar Energy Company SUNTREK INDUSTRIES 5 HOLLAND #215 IRVINE, CA 92618 C-46 LIC. #859460 (949) 348-9276 PROJECT SOLAR HOT WATER SYSTEM LOCATION Z D W q3Z U WQ W� }= N W w LLJ (f� p C14 H Q W Wa Q� NN L.I� ? . 0 0 z2C __ Ogg WQ VJ � J J O U) J Y Z DESIGNER A. HILL STORAGE TANK SPECS REVISIONS SHEET NO. C 0) THE MAKERS OF a r m s c a 11 Armaflex" engineered foams "R" Value for AP Armaflex* AP Armaflex insulation meets the energy code requirements of international Energy Conservation Code #ECQ, Intemational Residential Code #RC), CA Title 24, ASHRAE 901 and ASHRAE 90.2 Thermal resistance is used in combination with numerals to designate thermal resistance values: R-8 equals 8 resistance units. The higher the "R" value, the higher the insulating value. This value is normally calculated on a square foot basis. Thermal resistances ("R" value) for &RM@�OGM TECHNICAL INFORMATION bulletin #004 October 2003 revised Nov 2010 This simple equation is true for any flat homogeneous material with parallel surfaces. It is common knowledge that with a flat layer of insulation that increasing the "R" value increases the thermal efficiency by the same factor. These simple relationships and these typical "R" values don't hold Don't compare apples and flat surfaces such as for sheet true when looking at cylindrical oranges! Typical "R" values are not material is easy to calculate. It is pipe insulations. For these applicable for cylindrical systems simply the thickness of the materials, the heat flow is not the such as pipe insulation. "R" value insulation divided by the thermal simple straight -through heat flow or thermal resistance Is a measure conductivity of the insulation. For found with the flat surface material, of the ability of a material to retard example, a two inch sheet of AP but rather a radial heat flow. This is heat flow. "R" is the numerical Armaflee with a thermal true because the inner radius reciprocal of "C" (thermal conductivity of 0.25 Btu•inth•ffoOF surface area is much smaller than conductance). has an "R" value equal to 8.0. the outer radius surface area. Heat flow / I Heat flow / Equivalent thickness I I 1 I Heat flow G Because of these differences in surface area, heat flow must be calculated using an equivalent thickness. For cylindrical pipe insulation, the following equation should be used to calculate the "R" value: r2 r2ln�t R k Where r1 = uninsulated pipe radius in inches r2 = insulated pipe radius in inches k = thermal conductivity, 0.25 BTU-in/hr ft2 °F This equation yields an "R" value on a square foot basis Using this equation, AP Armaflex Pipe and AP Armaflex SS Insulation have the following "R"values: 3sulation 3/8" 1 /2„ 5/8" 3/4" 7/8" 1-1/8" 1-3/8" 1-5/8" 1-1/2" IPS 2-1/8" 2" IPS 2-5/8" 2-1/2" IPS 3-1/8" 3" IPS 3-5/8" 4-1/8" 4" IPS 5" IPS 6" IPS 8" IPS You cannot compare "R" values calculated for flat surfaces with "R" values calculated for radial surfaces. They are not the same! AP Armaflex Sheet and Roll Insulation R -Values, Square Foot Basis Wall Thickness (inches) Wall Thickness 1/2' 3/4" V Nam, 2M" Nom.1/2" Nom. Nam. 11` Nam. 1-1/2„ „ 2.9 3.4 -W 7.4 - - 2.7 3.3 Q ,5.5 7.2 - - 2.5 3.3 7.1 11.4 17.6 2.4 3.3 5.4 6.9 10.8 16.7 2.3 3.3 5.4 6.9 10.3 15.9 2.2 3.2 5.3 7.2 9.6 14.8 2.1 3.1 5.1 7.3 9.0 13.9 2.4 3.1 4.9 7.2 8.6 13.3 2.3 3.1 4.8 6.9 8.3 12.7 2.3 3.1 4.7 6.7 8.1 12.3 2.2 3.1 4.6 6.6 7.8 12.0 2.2 3.0 4.5 6.4 7.7 11.6 2.2 3.0 4.4 6.3 7.5 11.4 2.2 2.9 4.3 6.2 7.4 11.1 2.1 2.9 4.3 6.1 7.2 10.8 - 2.9 4.2 6.0 7.1 10.8 - 2.8 4.2 5.9 7.0 10.4 - 2.8 4.1 5.8 6.8 10.2 - 2.8 4.0 5.6 6.6 9.8 - 2.7 3.9 5.5 6.4 9.5 - 2.7 3.8 5.3 - - You cannot compare "R" values calculated for flat surfaces with "R" values calculated for radial surfaces. They are not the same! AP Armaflex Sheet and Roll Insulation R -Values, Square Foot Basis Wall Thickness (inches) For More Information Contact Us Via: Phone: (919) 304-3846 Fax: (919) 304-3847 Email: info.us0armacell.com Website: wyfw.armacell.us C SUNTREK Your Solar Energy Company SUNTREK INDUSTRIES 5 HOLLAND #215 IRVINE, CA 92618 C46 LIC. #859460 (949)348-9276 PROJECT SOLAR HOT WATER SYSTEM LOCATION F_ - Z Z) W gz U WQ W 0 JLC) w J rn I"- Q W LW z - 1-- O Z� O=. OT- WQ U)g� J Q U) J Y Z Fa - DESIGNER A. HILL Pipe Insulation R -Value REVISIONS SHEET NO. SHW-6 3/8" 1/2' 3/4" V 1-1/2" 2- R -Value 1.6 2.1 3.1 4.2 6 8 For More Information Contact Us Via: Phone: (919) 304-3846 Fax: (919) 304-3847 Email: info.us0armacell.com Website: wyfw.armacell.us C SUNTREK Your Solar Energy Company SUNTREK INDUSTRIES 5 HOLLAND #215 IRVINE, CA 92618 C46 LIC. #859460 (949)348-9276 PROJECT SOLAR HOT WATER SYSTEM LOCATION F_ - Z Z) W gz U WQ W 0 JLC) w J rn I"- Q W LW z - 1-- O Z� O=. OT- WQ U)g� J Q U) J Y Z Fa - DESIGNER A. HILL Pipe Insulation R -Value REVISIONS SHEET NO. SHW-6 (3 NORITZ Model NRC663-FSV (EZTR40) Series Residential Condensing Tankless Water Heater Specification Sheet -Standard Input- Gas consumption ranges from 15,000 BTUh to 120,000 BTUh -apacityange-Flow rates from 0.5 GPM up to 6.6 GPM 'ompactesign- ANSI Z21.10.3/CSA 4.3 certified design for indoor wall -mounting 'urableteelasingo lyesteroating 'Ventinglndoor venting only. N -Flex Kit (included) is designed for the installation inside of B -Vent as a sleeve. 'irectlectronic •nergyactor- 0.91 (NG) 0.91 (LP) -Temperatureontrols- Includes built in display that can preset the output temperature to either 120°17,135*17, or 140°F •owerordtionit- 6 power cord is included and attached 'afetyevices-Flame Sensor, Overheat Prevention Device, Lighting Protection Device, Freeze Protection, Condensate Overfill, Fan Rotation Detector 'dditionaleaturesTemperature Lockout, High Elevation Adjustment -ea r*edeatxchangerWarrantyortanda rdtialse *earedartsWarranty -as Use new or existing 1/2 gas line. For supply gas pressure <8 W.C. use gas line up to 1 Q for supply pressure >= 8 W.C. use gas line up to 100 *pprovals- CSA, UPC**, NSF, Low NOx Approved by SCAQMD [<14 ng/J or 20ppm] 'rJ4T7 NRC663-FSV Model NRC663-FSV - _ Accessories ❑ Remote Controller (#RC-765IM) ❑ Condensate Neutralizer (#NC -1) ❑ Isolation Valves (#IK -WV -200 -1( -LF))* ❑ Remote Controller Cord (#RC -CORD 10) ❑ Remote Controller Cord (#RC-CORD26) ❑ Vent Kit (#N-FlexKit2-35)* 'Included In Box with EM40 * Heat Exchanger warranty Is maintained at 12 years or 6500 operational hours, whichever occurs first when used in a single family dwelling in conjunction with a controlled recirculation system (an aquastat being the minimum pump control requirement) in accordance with the Installation Manual. Refer to the Noritz Limited Warranty for complete coverage details **This product complies with California AB 1953 Low Lead Law LOW -LEAD NSE ' ® � E 12 Years replacement on the heat exchanger when the product is used In a single family dwelling.3 Years replacement on heat exchanger when the product is used for commercial capacity, ifit is used in other than a single family dwelling, or if the product is supplied with pre -heated or circulated water (an aquastat being the minimum pump control requirement). Refer to the Noritz Limited Worranry for complete coverage details. —This product complies with California AB 1953 Low Lead Law and Section 1417(d) of the Safe Drinking WaterAct. NORITZ AMERICA CORPORATION 11160 Grace Avenue, Fountain Valley, CA 92708 Tel. 1-866-7N0&4M.noritz.com riow mates Temperature 30 40 45 50 60 70 80 90 100 Rise ('F Hot Water Outlet 314" Gas Inlet 1/2" Condensate Drain 1/2" Flow Rete 6.6 5.5 1 4.9 1 4.4 3.7 1 3.2 2.8 1 2.6 2.2 (GPM) Default Temperature Option 'FMode 'C Mode 120, 130,135,140'F Default Is 120'F) 50. 55, 57, 60'C Default is 50'C . 0). 0.0 Pressure Loss Characteristics 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 Flow rate [GPM) Specifications 90 80 70 60 6 50 m 40 30 a 20 10 0 Model Name NRC663-FSV (F1TR40) Weight 50 (pounds) Water Holding Capacity 0.2 Gallon (0.9 L) Water Inlet 3/4' Connection Sizes Hot Water Outlet 314" Gas Inlet 1/2" Condensate Drain 1/2" Power Supply 120VAC (60Hz) Consumption NG: 83W LP: 80W Freeze Prevention 129W Freeze Protection Outdoor. -4'F Temperature Settings with 'F Mode Optional Remote Controller "C Mode 115140'17 In 5'F Intervals) 6 Options) 46, 47, 48, 50, 55, 60'C (6 Options Default Temperature Option 'FMode 'C Mode 120, 130,135,140'F Default Is 120'F) 50. 55, 57, 60'C Default is 50'C Noritz America reserves the right to discontinue, or change at any time, the designs and/or specifications of Its products without notice. Rev. 3/15 FA SUNTREK Your Solar Energy Company SUNTREK INDUSTRIES 5 HOLLAND #215 IRVINE, CA 92618 C-46 LIC. #859460 (949) 348-9276 PROJECT SOLAR HOT WATER SYSTEM LOCATION F_ Z D W z U F_Q VJ Lu N W W U) 0 Q W IZ - ? - F— O Z 0a 0:5 Q ) CD J c� Q U) s� W Y Z DESIGNER A. HILL Tankless Gas Heater Specs REVISIONS SHEET NO. SHW-7 Overview: NOIR,I'T . i s NSF LOW -LEAD No O Residential or Commercial Residential Installation Location Indoor Only Exhaust Type Single Vent Max Flow Rate 6.6 GPM Flow Rate @ 50°F Rise 4.4 GPM Flow Rate @ 80°F Rise 2.8 GPM Temperature Range 115°F -140°F Production Status Active Condensing Yes Minimum Activation Flow Rate 0.5 Water Quality Treatment May Be Necessary Technical Specs & Installation: Min Gas Input (Btu) 15000 Max Gas Input (Btu) 120000 Height (in) 27.2 Width (in) 18.3 Depth (in) 9.4 Weight (Ibs) 50 Thermal Efficiency 93% Energy Factor 0.91 Afue NIA Quick -Connect Compatible? No Cold Water Connection Size (in) 3/4 _ Hot Water Connection Size (in) 3/4 Gas Connection Size (in) 1/2 - Power Supply 120 VAC (60 Hz) . Current Draw (A) 1.77 Exhaust Vent Diameter Requirements Centrotherm 2" -Flex Exhaust Vent Material Requirements Centrotherm 2" -Flex only (Not applicable PVC venting) Max Vent Length with 1 elbow 35' with 45°-2elbow Vent Termination Clearances to Any Building Opening(ft) Below = 4', Side = 4', or Above = V Gas Supply Pressure Range 4 -10.5" WC Min Gas Line Size 1/2" is N/A, 314" up to 30' Water Pressure Rating (psi) 15-150 Case Clearances (in) Top = 12", Front = 4", Sides = 3", Back = 0.. Combustion Air Requirements - using Indoor Air 180 In' Accessories: Keypad/Thermostat Display Not Included Compatible Remote Controller Part # RC -7651M Isolator Valve Part # IK-WV-200-1-xx Freeze Protection Yes Freeze Protection Kit Accessory NIA Outdoor Vent Cap Part # N/A Pipe Cover Part # NIA Recess Box Part # N/A Approvals: ENERGY STAR@ Qualified Yes CSA Yes (US Only] Mobile Home No NSF Yes SCAQMD (20 ppm) Yes SCAQMD (55 ppm) No UPC Yes Warrantv: Heat Exchanger Warranty (w/out 12 Years' Recirculation) Heat Exchanger Warranty 3 Years (w/Recirculation) Freeze Protection Yes Freeze Protection Rating - Indoor Temp 32°F Freeze Protection Rating - Outdoor Temp N/A Recirculation Compatible? Yes New Generation Model Number N/A Previous Name N/A Available Temperature Settings (with remote) 115, 120, 125, 130, 135, 140°F Default Temperature Setting (without remote 120°F Default Temperature Program Setting Options (without remote) 120, 130, 135, 140-F Production Date Range 8/2014 - Present Combustion Air Requirements - using Outdoor Air _ 100 int Head Loss at 2 gpm N/A Cold Connection Height 2.4" Power Consumption w/out Freeze Prevention 83 Watts Power Consumption w/Freeze Prevention 129 Watts Flow Meter Alarm Yes, with optional remote Service Reminder No Condensate Handling Method? NC -1 ' Noise Rating (dB) , . 48 016 Tested to UL Computer Controlled Safety Standards Yes Flame Sensor Yes High Limit Switch Yes Lightning Protection Yes Overheat Cutoff Fuse Yes Temperature Lockout " Yes Ignition Type Direct Electronic Case Material Durable Steel Casing with Polyester Coating Color/Finish Beige Flue Collar Material Stainless Steel Primary Heat Exchanger Material Copper Secondary Heat Exchanger Material Stainless Steel Mounting Type Wall Hung Package Contents Anchoring Screws, Owner's Guide, Warranty, Installation Manual 1 Water Holding Capacity 0.2 gallons High Elevation Adjustment Yes (Max. 3,500 ft.) Quick -Connect Cord Part # N/A System Controller Compatible? No System Controller Part # N/A Remote Controller Cord Not Included Compatible Remote Controller Cord Part # N/A Power Cord Included attached Energy Guide - Est. Yearly Energy Use 162 therms Energy Guide - Est. Yearly Operating Cost $177 UPC Low Lead Yes ASME (HLW) No ASME (H) No ASME (NB) No Parts Warranty 5 Years Labor Warranty 1 Year n SUNTREK Your Soler Energy Company SUNTREK INDUSTRIES 5 HOLLAND #215 IRVINE, CA 92618 C-46 LIC. #859460 (949)348-9276 PROJECT SOLAR HOT WATER SYSTEM LOCATION I— Z W z v F - Q W �z gU-) 0� w V! J Q W LwL Z j Er- O Z � c� O = OMgCKQ U (D J 0 J O � W Y Q DESIGNER A. HILL Tankless Gas Heater Specs REVISIONS SHEET NO. SHW-7.1