Loading...
SFD (04-6433)� oz V � BUILDING & SAFETY DEPARTMENT ya "�'mw4 P.O. Box 1504 (760).777-7012 OF94` 78-495 CALLE TAMPICo FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153 BUILDING PERMIT Application Number <Z040 p 433---�— --� Date 9/24/04 Property Address 566'25 MOUNTAIN____V_LEW APN: 762-420-040- - - Application description DWELLING - SINGLE FAMILY DETACHED Property Zoning LOW DENSITY RESIDENTIAL. Application valuation 376373 Owner Contractor ---------------- TOLL BROTHERS'INC. TOLL BROS, INC. 81380 LEGENDS WAY 73121 FRED WARING DRIVE, ##100 LA-QUINTA CA 92253 PALM DESERT CA 92260 WCC: LIBERTY MUTUAL WC: WA162D004723014 09/01/01 CSLB: 777699 04/30/0( CCC: B Structure Information ------ Constructibn.Type . . . . . TYPE V - NON RATED Occupancy Type DWELLG/LODGING/CONG <=10 Flood Zone . . NON -AO FLOOD ZONE - Other struct info . . . :CODE EDITION 2001 CRC FIRE SPRINKLERS NO GARAGE -SQ -FTG 73.0.00 PATIO SQ FTG 650.00 �:. -NUMB ER>AOF UNITS ; ,:. 1.00 FIRST FLOOR SQ FTG 4374.00 ----------------------- Permit BUILDING PERMIT Additional desc - Permit.Fee 1609.00 Plan Check Fee 261.46 .Issue Date. Valuation 376373 Qty Unit Charge Per Extension BASE FEE 639.50 277.00 3.5000 THOU BLDG 100,001-500,00.0 969.50 ------------ Permit . . . MECHANICAL Additional desc Permit Fee 134.00 Planhedk Feer! 8.38 Issue Date p V_.aluati(D 0 Qty Unit Charge Per OCT 2 0 2004 Extension BASE FEE 15.00 CITY OF LQUINTA . FINANCE. . P.O. Box 1504//��� 78-495 CALLE Tan-trlCo qV VOICE (760) 777-7012 LA QUINTA, CALIFORNIA 92253 44FAX (760) 777-7011 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: Q - (p144133 Date: 020'0 y Applicant: chitect or En Applicant's Mailing Address: glneera Tal. L. A(Le-A I J[ CcToa-X --Architect or Engineer's Address: Ic. No.: (%—Z-7CJS 1 ItSUILUING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and myLicnse is in full force and effect. ,cense Class IS,cense No. l� Date t 0'2.o — ontractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , B.& P.C. for this reason Date WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation inys ranee carrier and policy number are: rier Lf3 1ER.T MvZypt icy Number li1A-? 6Z. 00'4.7T3O1A I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address IMPORTANT APPLICANT ACKNOWLEDGEMENT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to anypernit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnity and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. 1 certify that 1 have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. S14 Signature (Applicant or Agent): l l Page 2., Application Number '. . . . . 04=00006433 Date 9/24/04, ' Qty Unit `Charge Per Extension 3.00 9.0000 EA MECH FURNACE <=100K 27.00 3.00 9'.0000 EA MECH B/C <=3HP/100K BTU 27.00 9.00 6.5000 EA MECH VENT FAN 58.50 1.00 6'.5000 EA MECH EXHAUST HOOD 6.50 Permit ------------------------------ ELEC-NEW RESIDENTIAL Additional, desc Permit'Fee 182.69 Plan Check Fee.. . " 11.42 Issue Date . . . . Valuation . . . . 0 Qty . Unit" Charge Per Extension BASE FEE 15.00 4374.00 .0350 ELEC NEW RES -.1 OR 2 FAMILY 153.09 730.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 14.60 --------------- Permit ----------- --------------------------------------- PLUMBING ' ----------- Additional desc Permit Fee . . . . 216.00 Plan.Check Fee 13:50 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE 'FEE 15.00 24.00 6.0000 EA PLB FIXTURE 144.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1..00 9.0000 EA PLB LAWN SPRINKLER'.SYSTEM 9:00 10.00 .7500 EA PLB GAS PIPE >=5 7..50 1.00 15.0000 EA PLB GAS METER 15.00 Permit GRADING PERMIT Additional desc Permit Fee 15.00 Plan Check Fee .00 Issue Date . . . . Valuation 0 Qty Unit Charge Per Extension BASE FEE 15.00 Special Notes 'and Comments SFD - LOT 40 PLAN VENTANA,SB W/CASITA & Page 3 Application Number . . . 04-00006.433 Date 9/24/04 Special,'Notes and Comments :EXT PATIO 4374 S.F. PERMIT DOES NOT INCLUDE BLOCK WALL, POOL, SPA OR DRIVEWAY APPROACH. 75% PLAN CHECK'FEE REDUCTION.APPLIED FOR MULTIPLE ISSUANCE OF SAME PLAN TYPE. -------------------------------- Other Fees . . . . ------------------------------------- . . . . ART IN PUBLIC PLACES -RES ------- 440.93 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY'REVIEW FEE 26.15 DIF FIRE,PROTECTION-RES 97.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES` 225.00 DIF PARK MAINT FAC,- RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 37.63 DIF STREET MAINT FAC" -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary ' Charged Paid Credited Due Permit Fee Total 2156.69-, _00 .00 2156.69 Plan -Check Total 294.76 .00 .00 294.76 Other Fee Total 2909.71 .00 "•.00 2909.71 Grand Total 5361.16. ..00 .'00 5361.16 06/23/2005. 11:29. 951-686-8786 WESTERN INSULATION PAGE 05/11 Western ..... , a=ion L,, P9' RESIDENTIAL. CONTRACTING 4211 Latham Street • Riverside. California 92501 • Phone: (909) 686-8760 • Fax: (909) 686-6786 License # 794484 CF6R INSULATION CERTIFICATE.. THIS IS TO CERTIFY THAT INSULATION HAS BEEN.INSTALLED IN CONFORMANCE WITH THE CURRENT ENERGY REGULATION, CALIFORNIA ADMINISTRATIVE CODE, TITLE 24, STATE OF CALIFORNIA, IN THE BUILDING LOCATED AT: TRACT/PHASE: MUIRFIELD Q PGA WEST 1 PHASE 5 LOT#: 40 SITE ADDRESS: X56,625 MOUNTAIN: )EW,)- LA QUINTA, CA CEILINGS:BLOWN INSULATION MANUFACTURER: GREENFIBER THICKNESS: 8.1" R- VALUE: R-30 CEILINGS: BATTS MANUFACTURER: KANUF, THICKNESS: 10" R- VALUE: R-30 EXTERIOR WALLS: BATTS MANUFACTURER: KANUF THICKNESS: 6 1X' R- VALUE: R-19 GABLE ENDS & PLUMBING BAYS BATTS MANUFACTURER: KNAUF THICKNESS: 3 1/2"R-1/ALUE: R-11 GENERAL CONTRACTOR: TOLL BROTHERS BY: ... . TITLE: DATE: " INSULATION CONTRACTOR: WESTERN INSULATION, L.P, LICENSE NUMBER: 794484 BY. TITLE: PR DUCTION PARAGER _ DATE: JUNE 23,:2005 1 1511005 27 52 7 9497525321 1® GOWIS ENGINEERING PAGE 01 >c March. 16, 200S . Allen Janisch Top Brothers 73-121 Fred Waring Diva. Suite 100 Palm Desert, CA 92260 Re: Muir-field at PGA West 3 SI_ 36� GECG Job * 60368-�Glriv�S �1 Ay l zPhase•s 38 Lots 237238and 240 l.'EG �N W py atiisch,��� 4 = &Z,Dear Mr. 1 . ta..) This letter advises that we have observed the structural requirements that are visible during construction at the time of our site visit. Gouvis Engineering believes that the as-built construction at the time of our visit (except items noted on ' flold notes) is In general conformance with our.structural plans and relevant correspondence Issued by our office relating to the above referenced dwelling. We observed the building in it; framed condition prior to installatlon of drywall and stucco. We observed the visual-and accessible structural requirements. (Exclusions are items such as: size of footings, reinforced steel In the foundations and roof sheathing.) " This report is uhdarscood to be an expresslon of profess►onal opinion by this angineer, which is based on his best knowledge, information and beliefs. is such, it consists of a report for only structural elements (as above outlined) and is neithor a guarantee nor a warranty,: expressed or implied for other trades or rgqulrements of subject dwelling., Respperfully Submitted; GOLPAS ENGINEERING CONSULTING GROUP, INC. Basil /lmmari F�Q�Wf0'ILf� Magdy Yacoub Director of field Operation �P ,t �L� `Field Quality Control ti w m e N0. C05M fn-, 949.7.2-'321 4400 Campos I lrivc 92660, PalmSprinw; (;q Plrw,mlan,C/C '$acr antcnto, t'n Snit 1,14 4'ily, UT No Chi Minh (:rte•. Vicrn.Tm