10-1264 (RER)P.O. BOX 1504 ^' VOICE (760) 777-7012
78-495 CALLE TAMPICO FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT' INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 12/15/10
Application Number: 10-00001264 Owner:
Property Address: 81845 MOUNTAIN VIEW LN BYRAM KEITH & GWEN
APN: 767-480-006- - - 81-845 MOUNTAIN VIEW LN
Application.description: REMODEL - RESIDENTIAL LA QUINTA, CA 92253
Property Zoning: LOW DENSITY RESIDENTIAL
Application valuation: 4000
Contractor: -
Applicant:., Architect or Engineer: _ EDWARDS CONSTRUCTION-.INC, B"
r 51455 DESERT CLUB DRIVE "
LA QUINTA_CA 92253
(760) 777-8202
' Lic. No.: 684857 `^ 0 21i f
1f
CES r %•t LA
•
-------------------------------------------------------------------------------
_-
LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION - -
I hereby affirm under penalty of perjury that 1 m licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: `
Section 70 01 o Division 3 of the Bu i zss rid P e "onals Code,,an my License is in full force and effect. _ I have and will maintain acertificate of consent to self-insure for workers' compensation, as provided '
License CI s: License o.: 684857+ for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
o j I -issued.
Date: •• l� � Contractor. - I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
X, - Code, for the performance of the work for which this permit is issued. My workers' compensation
OWNER-BUILDER DECLARATION insurance carrier, and policy number are: --
I
hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier GRANITE STATE - Policy Number WC 555-61-5 . 5 -
following reason (Sec. 7031.5. Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the work for which this permit is issued, 1 shall not employ any
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subje t to the workers' compensation laws of California, '
permit to file a signed statement that he or she is licensed. pursuant to the provisions of the Contractor's State - and agree that, if u be me ct t heworkers' co
ensation provisions of Section ,
License.Law (Chapter 9 (commencing with Section 7000) of Division.3 of the Business and Professions Code) or � 3700 of the Labor Coe I s all f with ply with those rovisions.
that he or she is exempt therefrom and the basis for the alleged exemption. Anyviolationof Section 7031.5 by. - N
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: Date: IZI&JID Applicant: -
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale ISec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND. CIVIL FINES UP TO ONE HUNDRED'THOUSAND ,
and who does the work himself or herself through his or her own employees; provided that the .DOLLARS 1$100,000). IN. ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN "
improvements are not intended or offered for sale. If, however, the building or improvement is sold within - SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S.FEES.
one year of completion, the owner-builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.). - APPLICANT ACKNOWLEDGEMENT -
(_) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the -
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application.
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1 . Each person upon whose behalf this application is made, each person at whose request and for
pursuant to the Contractors' State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application,
1 1 I am exempt under Sec. B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers; agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
Date: Owner: 2. Any permit issued as a result of this application becomes riull and void if work is not commenced
within 180 days from date of issuance of such permit; or cessation of work for 180 days will subject
CONSTRUCTION LENDING AGENCY permit to cancellation.
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the _ I certify that I have read this application and state that e a ov in o" n is correct. I agree to comply with all
work for which this permit is issued (Sec. 3097, Civ. C.). city and c my ordinances and state laws relating to ild' g ns n hereby author epresentatives
,. of this co ty enter upon the above-mentioned pr ins ction rp ses.
' Lender's Name: � l /tllp/,` -
" ate: r�/ V Signature_ (Applicant or Agent): -
Lender's Address: - -
Application Number . . . . . 10-00001264
------ Structure Information. NANA WALL CONVERSION AT REAR
PATIO -----
Other struct info . . . . . CODE EDITION
2007/2008
Permit . .. BUILDING PERMIT
Additional desc .
Permit Fee . . 63.00 Plan Check Fee
40.95
Issue Date . . . . Valuation . .
. . 4000
Expiration Date 6/13/11
Qty Unit Charge Per
Extension
BASE FEE
45.00
2.00, 9.0000 THOU. BLDG 2,001-25,000
18.00
Permit . ... ELECT - ADD/ALT/REM
Additional desc, '. . .
Permit Fee . . . . 15.75 Plan Check Fee
3.94
Issue Date Valuation . .
. . 0
Expiration Date 6/13/11
Qty Unit Charge Per
Extension
BASE FEE
15.00
1.00 .7500 PER. ELEC DEVICE/FIXTURE 1ST 20
.75
----------------------
;Special Notes and Comments
CONVERT EXISTING SLIDING GLASS DOORS. AT
REAR PATIO.TO NANAWALL [ENGINEERED]
2007/2008 CALIFORNIA BUILDING CODES.
December 15, 2010 2:.45:08 PM AORTEGA
--------------------------------------------
---------------------------"Other Fees . . . . . . . BLDG STDS ADMIN (SB1473)
Other
1.00
ENERGY REVIEW FEE
4.10
STRONG MOTION (SMI)'- RES .50
Fee'summary Charged Paid Credited
Due
Permit -Fee Total 78.75 .00 .00
----78 75
Plan Check Total 44.89 .00 .00
44.89.
.Other Fee Total 5.60 .00 .00
5.60
Grand Total 129.24 .00 .00
129.24
LQPERMIT -
1 I�
i l iziW_ "Z PC,
i 4liz — ,lc
Bin # ,G
8
Coy Of La Quill
' Building 8r Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
• I a,�Q (
fl
Project Address: (JC�Xill(%[f/
UI
wner's Name:
y
A. P. Number: -7
O ®t)
Address: 000z*&f ultzo t
Legal Description: f: 6
City, ST, Zip:
Contractor:
Telephone: —7-7 % v z
Project Description:
;
W fia.
Address:
City, ST, Zip:
Telephone:
C,/
State Lie. # : City Lie. C
r.,Designer:
Address: -7-7 _6 0 Z- C Q r g.
T, Zip: �_
Telephone: �� ��j `, _/ r
State Lie. #:
.Name of Contact Person:
Construction Type: Occupancy:
Project type (circle one): New Add, n Alter Repair Demo
Sq. FL:
#Stories:
#Units:
Telephone # of Contact Person:
6 S
Estimated Value of Project: _
1 i
APPLICANT: DO NOT WRITE BELOW THIS LINE
N
Submittal
Req'd
Recd TRACKING
PERMIT FEES
Pian Sets
Plan Check submitted
Al.
Item
Amount
Structural Calcs.
Reviewed, ready for corrections
t#O
Plan Check Deposit
^
Truss Calcs. -
Called- Contact Person
J
Plan Check Balance.
Tide 24 Cales.'Plans
picked up
Construction
joy; to
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
20° Review, ready for correctionsAssue
Electrical
Subcontactor List
Called Contact Person
Plumbing
--
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
''d Review, ready for correctionsAssue
Developer Impact Fee
Planning Approval
Called Contact Person
A.LP.P.
Pub. Wks. Appr
Date of permit issue '
�t ' VW
OL
School Fees���
Total Permit Fees
�Zq,
��,� / �//3 •Se2�ct� ��C� / 1�i5 : �1?
• I �JS'4J�-� � Q�hPf '� Itysv�:
YOUNG ENGINEERING: SER VICES www.,valuengrsom
6,w 71-780 San Jacigtq Dr. Ste: E2; Rancho Mirage Ca_. 92270 ph •(760) 834.-8860 fax "(760) 834-8861
C
Letter of Transmittal
To: City of La Quinta Today's Date: 12-13-10
78-495 Calle Tampico City Due Date: 12-14-10
La Quinta, CA 92253 Project Address: 81-845 Mountain View Lane
Attn: Phillip Plan Check #: 10-1264
Submittal: ❑ 1St ❑ 4'h
® 2nd ❑ 5th
❑ 3`d ❑ Other.
We are forwarding: ® By Messenger ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup
Includes: # Of Descriptions: Includes: # Of Descriptions:
Copies: Copies:
❑ Structural Plans ® 1 Revised Structural Plans
❑ Structural Calculations ® 1 Revised Struct. Calcs
❑ Truss Calculations ❑ Revised Truss
❑ Soils Report ❑ Revised Soils Report
® 1 Structural Comment List ❑ Approved Structural Plans
® 1 Redlined Structural Plans ❑ Approved Structural Calcs
® 1 Redlined Structural Calcs ❑ Approved Truss Calcs
❑ Redlined Truss Calcs ❑ Approved Soils Report
❑ Redlined Soils Reports ❑ Other:
Comments: Structural content isexOapprovable, see attached structural plan check comment list.
This Material Sent for:
❑ Your Files ® Per Your Request
❑ Your Review ❑ Approval
❑ Checking. ❑ At the request of:
Other: ❑
By: John W. Thompson
Rancho Mirage Office: ® (760) 834-8860
Other. ❑
Now
4
CLIENT-,�,,,, Robert A. Pitchford., Desigm_emmk..
4760) 346-2856 2.,
.1
CTBYM'M---R-E
MOD -EL
�aJE-
ADDT�E55;,, 81-8.45,,�'Mbuljta ew,
- - 'The Estates,
La.Q:ulntat.�_15,
JOB:
10-183
DATE: ,.7
December 2010
CIjTly
jt0F 1A. QU INT A
BUILDjNG'9SA__FETY DEP'Tt'
APPROVED
"FOR CONSTRUCTION,
DATEf" 1 13
STRUCTURAL AND CIVIL ENGINEERING
DENISE R. POELTLER, INC.;'
77725 ENFIELD LANE, STE. #130
PALM DESERT, CA 92211
TEL. (760) 772-4411 FAX (760) _772-4409
drpfly@aol.COM DIEC 0 7 2010
BY:
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Mr. & Mrs. Keith Byran
81-845 Mountian View .
La Quints,- CA 92253
Project Designer:
Robert A. Pitchford Design and Drafting
77-622 Country Club Dr. Suite O
Palm Desert, Ca 92211
(760) 346-2856
Report Prepared by:
Jon Scott
Scott Design. and Title 24, Inc, ��{ ; -- - - 71 -,�
77-085 Michigan Drive
.Y•
•r A
Palm, Desert, Ca 92211 t �� r
I NOV 1'8 2010 J
(760) 200-4780 (JLC
CITY.OF LA QUINTA
BUILDING & SAFETY DEPT.
Job Number: APPROVED
FOR CONSTRUCTION
Date: IDATE 8Y
11/15/2010
r The Energy Pro. computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
•authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
1� This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro5.1 by EnergySoft User Number. 6712 RunCode: 2010-11-15T08:22:08 /D:
1�
1�
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Mr. & Mrs. Keith Byran
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
11/15/2010_
Project Address
81-845 Mountian View La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floo
3,883 r Area
Addition
0
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity Features see Part 2 of 5 Status
Roof Wood Framed Attic R-19 3,383 Existing
Wall Wood Framed None 3,156 Existing
Slab Unheated Slab -on -Grade None 3,883 Perim = 350' Existing
FENESTRATION U- Exterior
Orientation Area f Factor SHGC Overhang Sidefins Shades Status_
Front (N) 132.8 0.550 0.67 none none Bug Screen Existing
Left (E) 78.0 0.550 0.67 none none Bug Screen Existing
Left (SE) 44.0 0.550 0.67 none none Bug Screen Existing
Rear (S) 195.0 0.550 0.67 none none Bug Screen - Existing
Rear (S) 158.0 0.350 0.46 none none Bug Screen New
Rear (SK9 20.0 0.550 0.67 none none Bug Screen Existing
Right (1M 76.0 0.550 0.67 none none Bug Screen Existing
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE Split Air Conditioner 10.0 SEER Setback
Existing
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
HVAC Existing Ducted Ducted Attic, Ceiling Ins, vented 4.2
Existing
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2010-11-15708:22:08 ID:
Page 3 of 12
r,
LJ
0
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
Mr. & Mrs. Keith Byran
Building Type ® Single Family ❑ Addition Alone
❑Multi Family ®Existing+ Addition/Alteration
Date
11/15/2010
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION -
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
J
EnemyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2010-11-15708:22:08 ID: Pa - e 4 of 12
r�
U
C
PERFORMANCE CERTIFICATE: Residential Part 3 of 5) CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Mr. & Mrs. Keith Byran
❑ Multi Family 10 Existing+ Addition/Alteration
1111151201C
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 16.62 16.58 0.04
Space Cooling 199.31 189.56 9.75
Fans 42.16 40.20 1.96
Domestic Hot Water 9.58 9.58 0.00
Pumps 0.00 0.00 0.00
Totals 267.67 255.92 11.74
Percent Better Than Standard: 4.4
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (N) 0 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (N) 1,000 133
Fuel Available at Site: Natural Gas (E) 1,050 122
Raised Floor Area: 0 (S) 1,080 373
Slab on Grade Area: 3,883 (M 730 76
Average Ceiling Height: 10.0 Roof 3,383 0
Fenestration Average U -Factor: 0.51 TOTAL: 704
Average SHGC: 0.62 Fenestration/CFA Ratio: 18.1;
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Scott Design and Title 24, Inc,
11/152010
Address 77-085 Michigan Drive Name Jon Scott
City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Robert A. Pitchford Design and Drafting
Address 77-622 Country Club Dr. Suite O Name Robert Pitchford 1
City/State/Zip Palm Desert, Ca 92211 Phone (760) 346-2856 Sign License # 6ate
Ene Pro 5.1 by EnemySoft User Number: 6712 RunCode: 2010-11-15708:22:08 ID: Page 5 of 12
r,
U
CERTIFICATE OF COMPLIANCE:
Residential
(Part 4 of 5) CF -1 R
Project Name
Mr. & Mrs. Keith Byran
Building Type m Single Family ❑ Addition Alone
❑ Multi Family 10 Existing+ Addition/Alteration
Date
1/15/201
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity_Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof
3,383
0.049 R-19
0
0 Existing 4.2.1-A4
Altered Residence
Wall
867
0.356 None
0
90 Existing 4.3.1-A1
Altered Residence
Wall
622
0.356 None
90
90 Existing 4.3.1-A1
Altered Residence
Wall
306
0.356 None
135
90 Existing 4.3.1-A1
Altered Residence
Wall
647
0.356 None
180
90 Existing 4.3.1-A1
Altered Residence
Wall
60
0.356 None
225
90 Existing 4.3.1-A1
Altered Residence
Wall
624
0.356 None
270
90 Existing 4.3.1-A1
Altered Residence
Wall
30
0.356 None
315
90 Existing 4.3.1-A 1
Altered Residence
Slab
3,883
0.730 None
0
180 Existing 4.4.7-A1
Altered Residence
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC
Azm Status
Glazing Type
Location/Comments
1
Window
20.0 0.550 Default
0.67 Default
0 Existing
Double Non -Metal Clear
Altered Residence
2
Window
20.0 0.550 Default
0.67 Default
0 Existing
Double Non -Metal Clear
Altered Residence
3
Window
48.0 0.550 Default
0.67 Default
0 Existing
Double Non -Metal Clear
Altered Residence
4
Window
20.0 0.550 Default
0.67 Default
0 Existing
Double Non -Metal Clear
Altered Residence
5
Window
20.0 0.550 Default
0.67 Default
0 Existing
Double Non -Metal Clear
Altered Residence
6
Window
4.8 0.550 Default
0.67 Default
0 Existing
Double Non -Metal Clear
Altered Residence
7
Window
30.0 0.550 Default
0.67 Default
90 Existing
Double Non -Metal Clear
Altered Residence
8
Window
48.0 0.550 Default
0.67 Default
90 Existing
Double Non -Metal Clear
Altered Residence
9
Window
24.0 0.550 Default
0.67 Default
135 Existing
Double Non -Metal Clear
Altered Residence
10
Window
10.0 0.550 Default
0.67 Default
135 Existing
Double Non -Metal Clear
Altered Residence
11
Window
10.0 0.550 Default
0.67 Default
135 Existing
Double Non -Metal Clear
Altered Residence
12
Window
30.0 0.550 Default
0.67 Default
180 Existing
Double Non -Metal Clear
Altered Residence
13
Window
48.0 0.550 Default
0.67 Default
180 Existing
Double Non -Metal Clear
Altered Residence
14
Window
30.0 0.550 Default
0.67 Default
180 Existing
Double Non -Metal Clear
Altered Residence
15
Window
30.0 0.550 Default
0.67 Default
180 Removed Double Non -Metal Clear
Altered Residence
16
Window
14.4 0.550 Default
0.67 Default
1801 Removed Double Non -Metal Clear
JAItered Residence
(1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t Wd
Ove hang Left Fin
Len FIRL LExt RExt Dist Len
Right Fin
H t Dist Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
Bug Screen
0.76
16
IBug Screen
0.76
EnergyPro
5.1 by EnergySoft User Number: 6712 RunCode: 2010-11-15708:22:08 ID:
Page 6 of 12
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF -1 R
Project Name
Mr. & Mrs. Keith Byran
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
1/15/201
OPAQUE SURFACE DETAILS
Surface U-
Type Area Factor
Insulation Joint Appendix
Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID
Type Area
U -Factor
SHGCz
Azm Status Glazing Type
Location/Comments
17
Window 48.0
0.550 Default
0.67 Default
180 Removed Double Non -Metal Clear
Altered Residence
18
Wndow 14.4
0.550 Default
0.67 Default
180 Removed Double Non -Metal Clear
Altered Residence
19
Wndow 36.0
0.550 Default
0.67 Default
180 Removed Double Non -Metal Clear
Altered Residence
20
Wndow 14.4
0.550 Default
0.67 Default
180 Removed Double Non -Metal Clear
Altered Residence
21
Window 128.0
0.350 NFRC
0.46 NFRC
180 New Double Non Metal Tinted
Altered Residence
22
Window j 10.0
0.350 NFRC
0.46 NFRC
180 New Double Non Metal Tinted
Altered Residence
23
Window 10.0
0.350 NFRC
0.46 NFRC
180 New Double Non Metal Tinted
Altered Residence
Window 10.0
0.350 NFRC
0.46 NFRC
180 New Double Non Metal Tinted
Altered Residence
•24
25
Window 30.0
0.550 Default
0.67 Default
180 Existing Double Non -Metal Clear
Altered Residence
26
Window 9.0
0.550 Default
0.67 Default
180 Existing Double Non -Metal Clear
Altered Residence
27
Window 48.0
0.550 Default
0.67 Default
180 Existing Double Non -Metal Clear
Altered Residence
28
Window 10.0
0.550 Default
0.67 Default
225 Existing Double Non -Metal Clear
Altered Residence
29
Window 10.0
0.550 Default
0.67 Default
225 Existing Double Non -Metal Clear
Altered Residence
30
Window 12.5
0.550 Default
0.67 Default
270 Existing Double Non -Metal Clear
Altered Residence
31
Window 12.5
0.550 Default
0.67 Default
270 Existing Double Non -Metal Clear
I Altered Residence
32
Window 7.5
0.550 Default
1 0.67 Default
270 Existing Double Non -Metal Clear
I Altered Residence
(1) LI -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
Hat F Wd
Ove hanq Left Fin Ri ht Fin
Len H t LExt RExt Dist Len Hat Dist Len Hat
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
0.76
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76
30
Bug Screen
0.76
31
Bug Screen
0.76
32
Bug Screen
0.76
•
EnergyPro
5.1 by EnergySoft User Number: 6712 RunCode: 2010-11-15708:22:08 ID:
Page 7 of 12
•
C
0
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
Mr. & Mrs. Keith Byran
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
1/15/201
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments
33 Window 36.0 0.550 Default 0.67 Default 270 Existing Double Non -Metal Clear Altered Residence
34 Window 7.5 0.550 Default 0.67 Default 270 Existing Double Non -Metal Clear Altered Residence
(1) U -Factor Type: 116-A =Default Table from Standards, NFRC =Labeled Value
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
Window Ove hang Left Fin Right Fin
ID Exterior Shade Type SHGC H tWd Len H t LExt RExt Dist Len Hq t .Dist Len Hq t
33 Bug Screen 0.76
34 Bug Screen 0.76
I '
EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2010-11-15T08:22:08 ID: Page 8 of 12
•
Ah
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5)
CF -1 R
Project Name
Mr. & Mrs. Keith Byran
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
11/15/201
BUILDING ZONE INFORMATION
System Name Zone Name New
Floor Area ff
Existing Altered Removed Volume Year Built
HVAC Existing Altered Residence
3,883
38,830 1960
Totals 01 3,883 01 0
HVAC SYSTEMS
System Name Ot . Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
HVAC Existing 1 Central Furnace 80 % AFUE Split Air Conditioner 10.0 SEER Setback
Existing
HVAC DISTRIBUTION
System Name Heating Coolinq
Duct
Duct Location R -Value
Ducts
Tested? Status
HVAC Existing Ducted Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
❑
WATER HEATING SYSTEMS
Name
Qty.
Type
Distribution
tSstem
qB
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
1
Small Gas
No Pipe Insulation
50
0.58
n/a
n/a
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
E
3
T
a-
Hot Water Piping Length
ft
o
76
a —
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qty.FHPw
Plenum Outside Buried
❑
❑
❑
❑
❑
❑
❑
❑
I
❑
❑
:Pa
EnemyPro 5.1 by EnemySoft User Number.- 6712 RunCode: 2010-11-15708:22:08 ID:
e 9 of 12
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
MA, . & Mrs -Keith Byran . ;- ;
Date
11/15/2010
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach'used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance .
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified,U-Factor,'certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of §10-111 (a). `
117: Exterior doors. and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118 (a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. •'
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§150(d): Minimum R-13 insulation in raised wood -frame floor ore uivalent U -factor. `
§150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -1R Form.
§150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
.rate is no'greater than 2.0 permAinch and shall be protected from h sical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built -fireplaces have a closable metal or lass doorcovering the entire opening of the firebox.
§150(e)1 B: Masonry or.factory-built fireplaces have a combustion. outside air intake, which is at least six square inches in area and is
e ui ped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, um isolation valve, and recirculation loo connection `requirements of 113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume'less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACOA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water '
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank. }
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-13.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150 ' 4: Solar water-heatingsystems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoff ',User Number. 6712 RunCode: 2010-11-15T08:22:08 ID: Page 10 of 12
r
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
1-1-1(1
r. & Mrs. Keith Byran
010
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
§114(b)2: Outdoor pools ors as that have a heat um or as heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run onlyduringoff-peak electric demand periods.
150 : Residential pool systems orequipment meet the um sizing, flow rate,piping, filters, and valve requirements of 150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoR User Number. 6712 RunCode: 2010-11-15708:22:08 ID: Page 11 of 12
4
F_
L_
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
r. & Mrs. Keith Byran
11111512010
§150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, _
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized.testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130 131, 134, and 146.
§150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoft User Number., 6712 RunCode: 2010-11-15708:22:08 ID: Page 12 of 12_