Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
12-1328 (AR)
P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 12' 00001328 Property Address: 81875 MOUNTAIN VIEW LN APN: 767-4,80-005- - - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 22000 4 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: HERNANDEZ MARTHA & FRANK 81875 MOUNTAIN VIEW LN LA QUINTA, CA 92253 Contractor: Applicant: Architect or Engineer: A & M CONSTRUCTION P.O. BOX 366 LA QUINTA, CA 92247 (760) 564 -4 832 Lic. No.: 746198 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury hat I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Bus. ass and Professionals Code, and my License is in full force and effect. License Class: B CIO .a License No.: 746198 Date: �; Contractor: OWNER -BUILDER DECLARATION hereby affirm under penalty of perjury that.l am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 _ I I am exempt under Sec. , BAP.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 1/16/13 D° JAN 16 2013 CITY OF LA QUINTA WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work'for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 9039845-13 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I s uld become subject to the workers' compensation provisions of Section 3700 of the Labor e, I shall�orthwith comply with those provisions.. Date: r� ;Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. _ 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and statethat he above information is correct. I agree to comply with all city and county ordinances and state laws relating to '(ding construction, and hereby authorize representatives of this cou%n/t/ I ter upon the above-ment.oned pr p rty for inspectiortrpurposes. Date: �`Y� '/ Signature (Applicant or Agent Application Number . . . . . 12-00001328 ------ Structure Information EXIST. 3818 SF SFD ----- Other struct info . . . . . CODE EDITION 2010 # BEDROOMS .00 FLOOD ZONE no PATIO SQ FTG 104.00 IST FLOOR SQUARE FOOTAGE 109.00 ------------------------------------------------------------------------- -- Permit . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 225.00 Plan Check Fee 146.25 Issue Date . . . . Valuation . . . . 22000 Expiration Date . . 7/15/13 Qty Unit Charge Per Extension BASE FEE 45.00 20.00 9.0000 THOU BLDG 2,001-25,000 180.00 ---------------------------------------------------------------------------- Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 18.82 Plan Check Fee 4.71 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 7/15/13 Qty Unit Charge Per Extension BASE FEE 15.00 109.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 3.82 ---------------------------------------------------------------------------- Permit MECHANICAL Additional desc . Permit Fee . . . . 24.00 Plan Check Fee 6.00 Issue Date Valuation . . . 0 Expiration Date 7/15/13 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 4.5000 EA MECH VENT INST/ DUCT ALT 9.00 ---------------------------------------------------------------------------- Special Notes and Comments 109 SF ENTRY ADDITION UNDER EXISTING ROOF, 92 SF PATIO TRELLIS ADDITION AT MASTER SUITE. WINDOW / SL. GL. DR ALTERATIONS. 2010 CODES. ENGINEER: REZA ASGHAPOUR. C67613. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 1.00 LQPERMIT Application Number . . . . . 12-00001328 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ENERGY REVIEW FEE 14.63 HOURLY PLAN CHECK 105.00 STRONG MOTION (SMI) - RES 2.20 Fee summary Charged Paid Credited Due ----------------- Permit Fee Total ---------- 267.82 -------------------- .00 ---------- .00 267.82 Plan Check Total 156.96 .00 .00 156.96 Other Fee Total 122.83 .00 .00 122.83 Grand Total 547.61 .00 .00 547.61 LQPERMIT Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 Project Name: LaQuinta Estates Owner's Name: Project Address: This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMFIND. AMOUNT: DATE: RECEIPT: CHECK#: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Martha & Frank Hernandez 81-875 Mountain View Lane LaQuinta Project Description: Front entry addition to an existing SFD APN: 767-480-005 Tract #: Type of Development: Residential xx Total Square Feet of Building Area Commercial 109 Date: December 18, 2012 Phone No. 760-564-4832 Lot #'s: Industrial Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under. penalty of perjury and further represents that he/she is authorized to sign behalf of the owner/developer. Dated: December 18, 2012 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABC E PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code Project Agreement Existing Not Subject to Fee 65995 Approval Prior to 1/1/87 Requirement Note: 109 Pursuant to AB 181 any room additions or enclosures of 500 $0.00 sq. ft. or less are exempt from developer fees. Any mobile homes being relocated within the same school district's $0.00 jurisdiction are exempt from developer fees. Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by: Laurie Howard, Secretary Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90-day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90-day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. Ccetikcriillcntc ol'a,in1 liance inini t: tL1tcd.,-'0(J7 11/2010 fQ11finta Oty Of La Perrnlr ufTding $C $�) @ li[L41t �.Q, Box 1544, 78499 Cabe 7'ampfca . � LA -Qu tita, G4 92253 - m(760) 777 7'a r 2 Btriiding Permit Application and Tracidng Sheet Project.Aildtess. ��j �'`i(j + R V 1 Vi Ltl- Owner's Name: A. P. Number- q - . Legal i]esaipunn: �^ �� Address: j%7 S ti t, Contractgr ` Cly. ,: iA T-A 3 L` ( A Ue � t Telephone city. ST, Zip: A 01,0 A CA Z Z� 3 �R !� �.���SCripii4A: ��`� � �I V i�l '�•'� �� n � V 1 ' V �d Telephone: _� ' _.6 1 - U3 L V I aeu SEate Lie. # : amity iia if; - Atd , Rngr., Designer _ Address: City, ST, Zip: S ' TeIeplio"I } t���'� " Stato Lic_ #: CoRstratxioR TYPO 00638n4y Name of Contat t Person: S ' Project type (cawde`*W): NMI Add'R Alter duo Telcphoac of Contact Person: [ fRFdmaw [J Value Of Pmf Cct APPLICANT: DO NOT VVWE BELOW THIS, LIME TP-kCMG PIRU Sets Plan Check tabwitted L FEW • Strgdatal Cafes �1 d� Review rea ed► dp for cart'ecUons �m Amaauc Truss Calce. y plan Check XTe posit, Mtie24 Cake• Caned Cautaetpersoa Plan CheekBatanez . k7000 Plata plan P[ans pEcErc�d ep i I Couatructioa Grading plan Plans resubmitted. 1 meciraided SubcoatactarT i 7 . Rev tw, ready carreCtio I +sit t F�techicaE Called Contactperaon l Plumbing Grant Deed Mans olaed ap R•U.fi. Apprtwal KIA G iL sas resaburiurd XL IN ExoUsB:-SALL Review; rtady for eorrectiaraslimae Grading Planningdeveloper Approval. 4lEotI Contact Pcrsm Impact Fee Pub. Wks. Appr Bateof PermitFstut School Fees '' / f.; �E�-yr.+l. LAC-GL- Z Z �g lilt r. , Total Permit Fees ► i I BUILDING ENERGY ANALYSIS REPORT I PROJECT: Hernandez Residence Remodel 81-875 Mountain View Lane La Quinta, CA 92253 Project Designer: South West Concepts 78-115 Calle Estado, Suite 105 La Quinta, CA 92253 (760) 564-4707 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 p ��n 1,xj NOV 0 8 2011 t+ By Job Number: Date: 11 /5/2012 II It ff Zrlc-F _ CITY OF !A QUINT, BUILDING & SAFETY DEP APPROVED FOR CONSTRUCTION :# 12132-?�, The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC—www.energysoft.com. I EnerovPro 5.1 by EneravSoft User Number: 6712 RunCode: 2012-11-05T18:02:46 ID: I I TABLE OF CONTENTS I Cover Page Table of Contents Form CF-1 R Certificate of Compliance Form MF-1 R Mandatory Measures Summary 2 3 12 PERFORMANCE CERTIFICATE: Residential (Part 1 of 5) CF-1 R Project Name Hernandez Residence Remodel Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 111512012 Project Address 81-875 Mountain View Lane La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 3,927 A ddition 109 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes IZI No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes IZI No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (fl) Features (see Part 2 of 5) Status Roof Wood Framed Attic R-19 3,818 Existing Wall Wood Framed R-11 Z593 Existing Door Opaque Door None 20 Existing Slab Unheated Slab -on -Grade None 3,818 Perim = 314' Existing Roof Wood Framed Attic R-38 109 New Wall Wood Framed R-13 111 New Door Opaque Door None 24 New Slab Unheated Slab -on -Grade None 109 Perim = 11' New FENESTRATION U- Exterior Orientation Area(f Factor SHGC Overhang Sidefins Shades Status Front (N) 126.3 0.710 0.73 none none Bug Screen Existing Front (N) 30.0 0.720 0.73 none none Bug Screen Existing Front (N) 32.8 0.710 0.73 none none Bug Screen Removed Left (E) 24.0 0.720 0.73 none none Bug Screen Existing Left (E) 44.6 0.710 0.73 none none Bug Screen Existing Left (SE) 16.3 0.710 0.73 none none Bug Screen Existing Rear (S) 239.0 0.710 073 none none Bug Screen Existing Rear (S) 210.0 0.710 0.73 none none Bug Screen Removed Rear (S) 44.0 0.710 0.73 8.0 none Bug Screen Removed Rear (SW 32.6 0.710 0.73 none none Bug Screen Existing Right (KO 71.0 0.710 0.73 none none Bug Screen Existing HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 3 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by FnergySoft User Number: 6712 RunCode: 2012-11.05T18:02:46 ID: Page 3 of 14 PERFORMANCE CERTIFICATE: Residential (Part 1 of 5) CF-1 R Project Name Hernandez Residence Remodel Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 111512012 Project Address 81-875 Mountain View Lane La Quinta California Energy Climate Zone Total Cond. Floor Area Addition CA Climate Zone 15 3,927 109 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A QF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (fi) Features see Part 2 of 5) Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Front (N) 45.0 0.520 0.36 none none Bug Screen New Rear (S) 180.0 0.520 0.36 none none Bug Screen New Rear (S) 80.0 0.520 0.36 8.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status En ergyPro 5.1 by EnergyScft user Number: 6712 Runcode: 2012-11-05T1a:02:46 IQ: Page 4 of 14 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name Hernandez Residence Remodel Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family m Existing+ Addition/Alteration Date 111512012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. EneroyPro 5.1 by Ene Soft User Number: 6712 RunCode: 2012-11-05T18:02:46 ID: Page 5 of 14 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date Hernandez Residence Remodel ❑ Multi Family m Existing+ Addition/Alteration 111512012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 9.68 8.16 1.52 Space Cooling 157.14 140.65 16.49 Fans 34.69 30.86 3.63 Domestic Hot Water 13.55 13.55 0.00 Pumps 0.00 0.00 0.00 Totals 215.06 193.22 21.84 Percent Better Than Standard: 10.2 % BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 0 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 1,180 201 Fuel Available at Site: Natural Gas (E) 590 85 Raised Floor Area: 0 (S) 1,347 532 Slab on Grade Area: 3,927 (IM 520 71 Average Ceiling Height: 10.0 Roof 3,927 0 Fenestration Average U-Factor: 0.65 TOTAL: 889 Average SHGC: 0.60 Fenestration/CFA Ratio: 22.6 % REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and comple Documentation Author Company Scott Design and Title 24, Inc, 111512012 Address 77-085 Michigan Drive Name Tim Scott City/state/zipCity/state/zip Palm Desert Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design re resented in this set of construction documents is consistent with the other compliance forms and worksheets, with the ecifications, and with any other calculations submitted with this permit application, and recognizes that compliance Ong duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope aling require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company South West Concepts %If Address 78-115 Celle Estado, Suite 105 Name Steve Nieto / `' City/State/Zip La Quinta, CA 92253 Phone (760) 564-4707 Signed License # Date EneravPro 5.1 by Ene Soft User Number-, 6712 RunCoda: 2012-11-05i18:02.46 ID' Page 6 of 14 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF-1 R Project Name Hernandez Residence Remodel Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 111512012 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame Roof 3,818 0.049 .R-19 2701 20 Existing 4.2.1-A4 Existing Residence Wall 894 0.110 .R-11 01 90 Existing 4.3.1-A2 Existing Residence Door 20 1.450 .None 0 90 Existing 4.5.1-A1 Existing Residence Wall 87 0.110 .R-11 0 90 Removec 4.3.1-A2 Existin2 Residence Door 48 1.450 .None 0 90 Remove •4.5.1-A1 Existina Residence Wall 451 0.110 R-11 90 90 Existing 4.3.1-A2 -Existing Residence Wall 100 0.110 R-11 90 90 Removec 4.3.1-A2 Existing Residence Wall 54 0.110 .R-11 135 90 Existin 4.3.1-A2 -Existing Residence Wall 688 0.110 R-11 180 90 Existing 4.3.1-A2 Existin2 Residence Wall 86 0.110 R-11 180 90 Remove 4.3.1-A2 Existina Residence Wall 57 0.110 R-11 225 90 Existing 4.3.1-A2 Existing Residence Wall 449 0.110 R-11 270 90 Existing 4.3.1-A2 Existing Residence Wall 100 0.110 .R-11 270 90 Remov 4.3.1-A2 Existing Residence Slab 3,818 0.730 None 0 180 Existing 4.4.7-A1 Existing Residence Roof 109 0.026 R-38 Ll�01 270 0 New 4.2.1-A9 lExisting Residence Wall 41 0.102 R-13 0 New 4.3.1-A3 lExisting Residence FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHG Azm Status Glazing Type LocatonfComments 1 Window 30.0 0.710 Default 0.73 1 Default 0 Existing Existing Window Existing Residence 2 Window 6.3 0.710 Default 0.73 Default 0 Existing Existing Window Existing Residence 3 Window 30.0 0.710 Default 0.73 Default 0 Existin Existing Window Exislln Residence 4 Window 30.0 0.710 Default 0.73 Default 0 Existing Existing Window Existing Residence 5 Window 30.0 0.710 Default 0.73 Default 0 Existing Existing Window Existing Residence 6 Window 30.0 0.720 1 Default 0.73 Default 0 Existing Glass Block Existing Residence 7 Window 11.3 0. 7101 Default 0.73 Default 0 Removed Existing Window Existing Residence 8 Window 10.2 0. 7101 Default 0.73 Default 0 Removed Existing Window Existing Residence 9 Window 11.3 0.710 Default 0.73 Default 0 Removed Existing Window Existing Residence 10 Window 24.0 0.720 Default 0.73 Default 90 Existing Glass Block Existing Residence 11 Window 12.0 0.710 Default 0.73 Default 90 Existing Existing Window Existing Residence 12 Window 12.5 0.710 Default 0.73 Default 90 Existing Existing Window Existing Residence 13 Window 3.8 0.710 Default 0.73 Default 90 Existing Existing Window Existing Residence 14 Window 12.5 0.710 Default 0.73 Default 90 Existing Existing Window Existing Residence 15 Iffindow 3.8 0.710 Default 0.73 Default 90 Existing Existing Window Existing Residence 16 indow 12.5 0.710 Default 0.73 Default 135 Existing Existing Window Existing Residence (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hanq Left Fin Ricilht Fin H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 ,Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Buy Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 [Bua Screen 0.76 EnerqyPfo 5.1 by En erg Soft User Number. 6712 RunCode: 2012-11.05T18:02:46 ID: Page 7 of 14 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Hernandez Residence Remodel Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 111512012 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm I Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interiorl Frame Door 24 1.450 None 01 90 New 4.5.1-A1 Existing Residence Wall 70 0.102 R-13 160 90 New 4.3.1-A3 _Existing Residence Slab 109 0.730 None 0 180 New 4.4.7-A1 Existing Residence FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHG Azm Status Glazin Type Location/Comments 17 'Window 3.8 0.710 Default 0.73 Default 135 Existing Existing Window Existing Residence 18 'Window 48.0 0.710 Default 0.73 Default 180 Existing Existing Window Existing Residence 19 'Window 18.0 0.710 Default 0.73 Default 180 Existing Existing Window Existing Residence 20 'Window 30.0 0.710 Default 0.73 Default 180 Existing Existing IMndow Existing Residence 21 Window 9.0 0.710 Default 0.73 Default 180 Existing Existing Window Existing Residence 22 Wndow 20.0 0.710 Default 0.73 Default 180 Existing Existing Window Existing Residence 23 Window 6.0 0.710 Default 0.73 Default 180 Existing Existing Window Existing Residence 24 Window 20.0 0.710 Default 0.73 Default 180 Existing Existing Window Existing Residence 25 Window 6.0 0.710 Default 0.73 Default 180 Existing Existing Window Existing Residence 26 Window 20.0 0.710 Default 0.73 Default 180 Existing Existing Window Existing Residence 27 Window 6.0 0.710 Default 0.73 Default 180 Existing Existing Window Existing Residence 28 Window 20.0 0.710 Default 0.73 Default 180 Existing Existing Window Existing Residence 29 Window 36.0 0.710 Default 0.73 Default 180 Existing Existing Window Existing Residence 30 Window 18.0 0.710 Default 0.73 Default 180 Removed Existing Window Existing Residence 31 Window 30.0 0.710 Default 0.73 Default 180 Removed Existing Window Existing Residence 32 Window 9.0 0.710 Default 0.73 Default 1801 Removed Existing Window Existing Residence (1) U-Factor Type: 116-A = Default Table from Standards, NFRG = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin Right Fin H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 En eqjyPro 5.1 by EnergySoft User Number. 6712 Run Cade: 2012-11-05T18:02:46 ID: Page 8 of 14 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Hernandez Residence Remodel Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 111512012 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Tilt Status Joint Appendix 4 Location/Comments CavIty Exterior Frame InteriorlFramel Azm FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC` Azm Status Glazing Type Location/Comments 33 'Window 18.0 0. 7101 Default 0.73 Default 180 Removed Existing Window Existing Residence 34 'Window 30.0 0. 7101 Default 0.73 Default 160 Removed Existing Window Existing Residence 35 'Window 9.0 0. 7101 Default 0.73 Default 180 Removed Existing Window Existing Residence 36 'Window 48.0 0.710 Default 0.73 Default 180 Removed Existing Window Existing Residence 37 'Window 18.0 0.710 Default 0.73 Default 180 Removed Existing Window Existing Residence 38 Window 48.0 0.710 Default 0.73 Default 180 Removed Existing Wrndow Existing Residence 39 Window 20.0 0.710 Default 0.73 Default 180 Removed Existing Window Existing Residence 40 Window 6.0 0.710 Default 0.73 Default 180 Removed Existing Window Existing Residence 41 Window 12.5 0.710 Default 0.73 Default 225 Existing Existing Window Existing Residence 42 Window 3.8 0.710 Default 0.73 Default 225 Existing Existing Window Existing Residence 43 Window 16.3 0.710 Default 0.73 Default 225 Existing Existing Window Existing Residence 44 Window 20.0 0.710 1 Default 0.73 Default 270 Existing Existing Window Existing Residence 45 Window 6.0 0.710 Default 0.73 Default 270 Existing Existing Window Existing Residence 46 Window 18.0 0.710 Default 0.73 Default 270 Existing Existing Window Existing Residence 47 Window 9.0 0.710 Default 0.73 Default 270 Existing Existing Wrndow Existing Residence 48 Window 18.0 0.710 Default 0.73 Default 270 Existing Existing Window Existing Residence (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hanq Left Fin Right Fin H t Wd Len H t I LExt RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 8.0 6.0 8.0 0.1 8.0 8.0 38 Bug Screen 0.76 39 Bug Screen 0.76 1.5 4.0 8.01 0.1 8.0 8.0 40 0.76 5.0 4.0 8.0 0.1 8.0 8.0 41 Bug Screen 0.76 42 Buo Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 ,Bu Screen 0.76 48 1j9ug Screen 1 0.76 EnergyPro 5.1 by EnerqvSoft User Number, 6712 Run Co de: 2012-11.05T18:02.46 ID Pace 9 of 14 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Hernandez Residence Remodel Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date �111512012 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame I FENESTRATION SURFACE DETAILS ID Type I Area U-Factor SHGC Azm Status Glazing Type Location/Comments 49 Window 22.5 0.520 NFRC 0.36 NFRC 0 New Double Metal Tinted Existing Residence 50 Window 22.5 0.520 NFRC 0.36 NFRC 0 New Double Metal Tinted Existing Residence 51 Window 9.0 0.520 NFRC 0.36 NFRC 180 New Double Metal Tinted Existing Residence 52 Window 51.0 0.520 NFRC 0.36 NFRC 180 New Double Metal Tinted Existing Residence 53 Window 9.0 0.520 NFRC 0.36 NFRC 180 New Double Metal Tinted Existing Residence 54 Window 51.0 0.520 NFRC 0.36 NFRC 180 New Double Metal Tinted Existing Residence 55 Window 9.0 0.520 NFRC 0.36 NFRC 180 New Double Metal Tinted Existing Residence 56 Window 51.0 0.520 NFRC 0.36 NFRC 180 New Double Metal Tinted Existing Residence 57 Window 80.0 0.520 NFRC 0.36 NFRC 180 New Double Metal Tinted Existing Residence (1 ) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin Riczht Fin H t Wd Len tit I LExt RExt Dist Len H t Dist Len H t 49 Bug Screen 0.76 50 .Bug Screen 0.76 51 Bug Screen 0.76 52 ,Bug Screen 0.76 53 .Bug Screen 0.76 54 .Bug Screen 0.76 55 .Bug Screen 0.76 56 Bug Screen 0.76 57 Bug Screen 0.76 8.0 10.0 8.01 0.1 8.01 8.0 Ens Pm 5.1 by EnefclySoll User Number_ 6712 RunCode: 2012-11-05T18,02:46 ID: Pa a 10 of 14 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name Building Type © Single Family ❑ Addition Alone Hernandez Residence Remodel Multi Family m Existing+ Addition/Alteration Date 111512012 BUILDING ZONE INFORMATION Svstem Name Zone Name Floor Area fi Volume Year Built New Existing Altered Removed HVAC Existing Residence 3,818 38.,180 1995 Addition 109 1,090 Totals 1 1091 3,818 0 0 HVAC SYSTEMS System Name Qty. Heating T e Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 3 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Cooling I Duct Location Duct R-Value Ducts Tested? Status HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input (Btuh) Tank Cap. (gal) Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 2 Small Gas Kitchen Pipe Ins 40,000 50 0.54 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 ie N a c System Name Pipe Length Pipe Diameter Insul. Thick. Qtv. HP Plenum Outside Buried EnergyPro 5.1 by EnerqySQft User Number.' 8712 RunCode: 2012-11-05T18;02:46 ID. —Page 11 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name Date Hernandez Residence Remodel 111512012 NOTE: Low-rise residential bulldings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped: all joints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulating Material, Indicate type and include on CF-6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. * 150 a : Minimum R-19 insulation in wood -frame colling or equivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. * 150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor. * 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor. 150 : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 1 50: Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance -rate is no areater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e i A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air Intake, which is at least six square inches in area and is -equipped with a with a readily accessible, ❑ erable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibfted. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connectlon requirements of §113 c 5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h : Heating and/or coolinn loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150 : Heating systems are equipped with thermostats that meet the setback requirements of Section 1 12c . §150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped 'with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are Insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine Iines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150 ' 3A: Insulation is protected from damage, Including that due to sunlight, moisture, equipment maintenance, and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines Includes a vapor retardant or is enclosed entirely in conditioned space. 150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPrc 5.1 by Energ Soft User Number: 6712 RunCode: 2012-11-05T18:02:46 ID: Page 12 of 14 MANDATORY MEASURES SUMMARY: Residential Pa e 2 of 3 MF-1 R Project Name Date Hernandez Residence Remodel 1 111512012 §150(m)1-1 All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 114 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area -of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150 m 7: Exhaust fan systems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Celluiar foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSIIASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation -required in Section 4 of that Standard. Pool and Spa Keating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or bullt-up connections for future solar heating. 114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. 6114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, pipin2, filters, and valve requirements of 150 Residential Lighting Measures: §150(k)i : High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire as specified by §150(k)2, 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Lighting integral to exhaust tans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150 k 7: All switching devices and controls shall meet the re uirements of 150 k 7. §150(k)B: A minimum of 50 percent of the total rated wattage of permanently installed lighting In kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. 6150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of -illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-11-05T18:02:46 ID: Page 13 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date Hernandez Residence Remodel 111512012 §150(k)10: Permanently Installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy IuImnaires. EXCEPTION 1: Permanently installed low efficacy Iuminalres shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §1150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and cellin. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise Tesidentlal buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1 : Permanently installed outdoor law efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Intemally Illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined accordln to 130 d . §150(k)l 5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)t6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-11-05T18:02:46 ID: Page 14 of 14