Loading...
SFD (05-5588)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: a APN: Application description Property Zoning: Application valuation: Applicant: T4ht 4 - 4 Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT 05�70_&65588. 81960 MOUNTAIN VIEW LN 767-480-013- - - DWELLING - SINGLE FAMILY DETACHED LOW DENSITY RESIDENTIAL 480331 Architect or Engineer: -------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: License No.: Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by a y plicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: Int I �as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the .projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exemptunderSec, , B.&P.C. for this ason / v CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: - LQPERAIIT Owner: LARRY OWENS 77 545 ROBIN PALM DESERT, Other str Contractor: Owner DITION VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 RD. CA 92211 Date: 2/28/06 ----------------------------------------------- WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier 42n 4.00 Policy Number NO (,certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, hall fort with comply with those provisions. r Dai l„ O `.Appli�ag� WARWAR ING: FAILURE TO RE W KE 'COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL P NALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and coun ordinances and state laws relating to building pQnstruc�� ,and hereby authorize representatives of this cginty to enter upon the above-mentioned property J4rAsl 9tfoypurposes. Application Number . . . . . 05-00005588 Permit . . . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 1973.00 Plan Check Fee 1282.45 =� Issue Date . . . . Valuation . . . . 480331 Expiration Date . . 8/27/06 Qty Unit Charge Per Extension BASE FEE 639.50 381.00 --------------------------------------------------- 3.5000 THOU BLDG 100,001-500,000 ---------------------- 1333..50 --- Permit . . . ELEC-NEW RESIDENTIAL Additional desc . . Permit Fee . . . . 320.46 Plan Check Fee 80.12 Issue Date . . . . Valuation . . . . 0 Expiration Date 8/27/06 Qty Unit Charge Per Extension BASE FEE 15.00 7421.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 259.74 1536.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 30.72 1.00 ---------------------------------------------------------------------------- 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 8/27/06 Qty Unit Charge Per Extension ---------------------------------------------------------------------------- BASE FEE 15.00 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 119.50 Plan Check Fee 29.88 Issue Date . . . . Valuation . . . '. 0 Expiration Date 8/27/06 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 9.0000 EA MECH FURNACE <=100K 36.00 4.00 9.0000 EA MECH B/C <=3HP/100K BTU 36.00 4.00 6.5000 EA MECH VENT FAN 26.00 1.00 ----------- ---------------------------------------------------------------- 6.5000 EA MECH EXHAUST HOOD 6.50 LQPERA11T Application Number . . . . 05-00005588 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 223.50 Plan Check Fee 55.88 CIO Issue Date . . . . Valuation . . . . 0 Expiration Date 8/27/06 Qty Unit Charge Per Extension BASE FEE 15.00 16.00 6.0000 EA PLB FIXTURE 96.00 1.00 45.0000 EA PLB SEPTIC 45.00 4.00 7.5000 EA• PLB WATER HEATER/VENT 30.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 14.00 .7500 EA PLB GAS PIPE >=5 10.50 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 7270 SQ. FT.SFD. THIS PERMIT DOES NOT INCLUDE POOL & SPA BLOCK WALLS OR DRIVEWAY APPROACH.January 20, 2006 4:09:55 PM JJOHNSON ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 722.42 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 480.00 ENERGY REVIEW FEE 128.25 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 48.89 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1666.00 Fee summary Charged Paid Credited --------------------------------------------------------- Due Permit Fee Total 2651.46 .00 .00 2651.46 Plan Check Total 1448.33 500.00 .00 948.33 Other Fee Total 4595.56 .00 .00 4595.56 Grand Total 8695.35 500.00. ..00 8195.35 LQPERDIIT Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMIIND. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Larry_Qwens__(Residence'@ The Estates) Date: March 9, 2006 Owner's Name: Larry Owens Phone No. (760) 251-5454 Project Address: 81-960 Mountain View, La Quinta, CA Project Description: 1 Single Family Dwelling APN: 767-480-013 Tract #: Lot #'s: Type of Development: Residential !XX! Commercial Industrial Total Square Feet of Building Area: 7,270 sq. Ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: 03/09/06 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. 7,270 sq. ft. Amount per Sq.Ft. $ 2.88 Amount Collected $ 20,937.60 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Business Services Certificate issued by: Leticia C. Torres, Facilities Clerk NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES—AND STATEMIZNTi6F FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. l;1":r/nn 1i Csidc�'fi'.oc',?cortifi ato ofcompliancc fOrm tahlesTO I.jSFi.doc �J 1/16/03 T RECORDING REQUESTED BY: First American Title-Porscha Peterson AND WHEN RECORDED MAIL TO: Mr. and Mrs. Larry J. Owens 77545 Robin Road Palm Desert,'CA 92211 DOC N 2005-0864904 10/20/2005 08:00A Fee:7.00 Page 1 of 1 Doc T Tax Paid Recorded in Official Records County of Riverside Larry W. Ward Assessor, County Clerk & Recorder I IIIIII.IIIIIII III IIIIIII III IIIIII IIIIII III VIII IIII IIII I M I S I U II PAGE I SIZE I DA I PCOR /I NOCOR I SMF I MISC. I Title Order No.: "�}✓'1 Q' �lj I A I R I U II I COPY I LONG I REFUND. I NCHG I TRA# 20-059 GRANT DEED THE UNDERSIGNED GRANTOR(S) DECLARE(S) DOCUMENTARY TRANSFER TAX is $401.50 [X] computed on full value of property conveyed, or ] computed on full value less value of liens or encumbrances remaining at time of sale. Lij [ ] Unincorporated area [X] City of La Quinta AND FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Extreme Development, LLC hereby GRANT(s) to: Larry J. Owens and Terrie L. Owens, Husband and Wife G�5 �✓>`� �Ca/��n�S the real property in the City of La Quinta, County of Riverside, State of California, described as: U LOT 13 OF TRACT 26769, AS PER MAP RECORDED IN BOOK 235, PAGES 40 AND 41, INCLUSIVE OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. Also Known as: Vacant Lot - Mountain View Lane, La Quinta, CA 92253 AP#: 767-480-013 DATED September 21, 2005 STATE OF CA1, RNIA Extreme Development, LLC, a California Limited COUNTY OF � <Ve-t-51 C[C, Liability C ny On -Fe 2 Before e, A Notary Public in and foi said State, personally appeared By. Peter Brown personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS my hand and official seal. NANCY NEILEN- Commission # 1480500 z .,� Notary Public - California Z ' Y.. Riverside County My Comm. Expires Apr 5, 2008 Signature (This area for official notarial seal) MAIL TAX STATEMENTS TO A TY SH WN B LOW; IF NO PARTY SHOWN, MAIL AS DIRECTED ABOVE: I TITLE 24 REPORT I Title 24 Report for: LA Y & TERRIE OWENS 81- 0 MOUNTAIN VIEW LN. Cl.IT OF LH, ; bilis LA QUINTA, CA BUILDING & SAFI :.Y DEPT. APPROVED FOR COrNSTI . A;TION DA z$1Db BY-, _/ Project Designer: MR. LARRY K RS.TERRIE OWENS 77-$45 ROBIN RD. PALM DE-SERT, CA 92260 760-345-1889 Report Prepared By: ADRIANA GIL Adriana Gil 74-854 Velie Way Ste. #8 Palm Desert, CA 92260 (760) 404-7917 Job Number: ADY378-0206 Date: 2/8/2006 FEB 14 2006 U The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.0 by EnergySoft Job Number: ADY378-0206 User Number 5553 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form WS -5R Residential Kitchen Lighting HVAC System Heating and Cooling Loads Summary Room Load Summary 1 2 3 8 10 11 15 EnergyPro 4.0 by EnergySoft Job Number: ADY378-0206 User Number 5553 Certificate Of Compliance: Residential (Part 1 of 3) CF -1 R LARR_Y_8-T_E.RRI.E QW_ _ENS _436 .H_V.AC_Sp.l it_S.ystem_Zn_I I 2/_8/2006 Project Title c . Azm. BBA- C_SpliLSystem_Zn_I_V Date _81-98.0_M0-U_NTAI.N_V_I.EW_ LN. --LA Q.U_I.NTA I I t' A t _0..026_ -R=38_ Project Address 9.0_ 1.8 Building Permit # Adr_iana_Gil 5.51. (760)-404-7917 -R21 Documentation Author New -0.9 Telephone Plan Check/Date -ER@.f_qP_r_o Compli ce Method 25.5_ 15 Climate Zone _ER21 Field Check/Date 0__9.0 Source Energy Use Standard Proposed Compliance __311. (kBtu/sf-yr) Design Design Margin 9.0__90 Space Heating 1.38 1.83 -0.45 26_ Space Cooling 47.74 47.36 0.38 45__9.0 Fans 7.17 7.06 0.11 1.,.7.0.6_ Domestic Hot Water 4.07 3.69 0.38 _90_ Pumps 0.00 0.00 0.00 31.0_ Totals 60.36 59.93 0.42 0.9 _A6 better than Stan Building Type: [X-] Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (South)180 deg Natural Gas Area: 847 ft2 Avg. U: 0.34 Ratio: 13.4% Avg. SHGC: 0.28 BUILDING ZONE INFORMATION Zone Name Floor Area Volume .H_VA_ C_Split_System_Zn_I _436 .H_V.AC_Sp.l it_S.ystem_Zn_I I .,.7.0.6 .H_VAC Split_Sy_ste.m_Zn_I.I.I c . Azm. BBA- C_SpliLSystem_Zn_I_V Roof OPAQUE SURFACES I I t' A t 1., 1 3.80. 1.,.7_7.8 I 1_4,360 1.7_,.0.6.0 13,800 1.7_,.7_8.0 Type Frame Area U -Fac. nsu a Ion Cay. Cont. c . Azm. Tilt Roof Wood_ 1,4.36_ _0..026_ -R=38_ _R=0.0. 9.0_ 1.8 Wall_ Wood_ 5.51. _0._0.6.9_ -R21 _R=0..0_-27-0--9.0 New -0.9 -6 Wall_ Wood_ 25.5_ -0...0.6.9_ _ER21 _R=0.0_ 0__9.0 New -Wall-Wood- ZonelLCommoo_Areas __311. _0.069_ _R21. _R=0.0_ 9.0__90 Zone_]Mommon- reas Wall_ Wood_ 26_ _0..0.6.9_ _R=21. _R=0...0_ 45__9.0 _0.9=A6 .Roof Wood_ 1.,.7.0.6_ _0..026_ -R=38_ _R=0..0_ _90_ 1.8 -Wall- Wood- 31.0_ _0..069_ _R=21_ _R=0..0_-1.80--90 N .ew 0.9 _A6 Wall_ Wood- 388_ _0..069_ _R=21._R=0.0_-27.0__9.0 Wall_ Wood_ 32- _0._0.69_ -&2.1_ _R=0.0_ 0__9.0 Wall_ Wood_ 1.02_ _0..0.6.9_ -R21_ _R=0.0_ _90__9.0 Roof Wood- 1.,380_ _0.026_ -R=38_ _R=0..0. 9.0_ 1.8 Wall_ Wood- 54.3_ _0.069_ -R=21_ _R=0..0_ 1.80.9.0 Wall_ Wood_ 256_ -0...0.69_ -R21_ _R=0..0_ 0__9.0 Wall_ Wood_ 1.3.0_ -0...0.6.9_ -R=21 _R=0...0_ _315__9.0 Roof -W-0-0-d-d_ 1_,.7_7.8_ _0.026_ -R 3.8_ _R=0.0. 9.0_ 1.8 Wall_ Wood_ 1.91 _0.0.6.9_ _R=21. _R=0..0_ 1.8.0__90 Door Doo None- 2.4_ _0.500_ _None_ _R 0.0_ 1.80__9.0 Wall_ Wood- 1.62_ _0.069_ -R=21. _R=0..0_ _2.7.0.9.0 Wall- Wood_ 6.0_ _0.069_ -R=21_ _R=0.0_ -31.5__9.0 Wall_ Wood_ 642_ _0...0.6.9_ _R=21_ _R=0.0_ 909.0 Wall_ Wood_ t64_ _0._0.6.9_ _IR21_ _R=0..0_ 0__9.0 0.7% Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: Number of Stories: # of _01_A8 Thermostat Units Zone Type Type -0.23_ Conditioned- -Setback- _0..27_ Conditioned_ _S.etb.ack_ 0.22_ Conditioned_ Setback_ 0.2.8_ Conditioned_ Setback - 6,300 ft2 n/a ft2 0 ft2 6,300 ft2 10.0 ft 1.00 Vent Hgt. Area 2 -nLa _ 2 n/.a 2 _n/a -2 _n/a Gains Condition Y / N Status JA IV Reference Location / Comments New _01_A8 Zone-1-Master-Bedroom New _0.9=A6 Zone-LMastetB.edroom New _0.9=A6 Zone_I_Maste.r_B.edroom New .09=A6 Zone_I_Master_Bedroom New _0.9=A6 Zone_I_Master_B.edroo.m New 01=A8 Zone_ILBedrooms New 0.9=A6 Zone_11Bedrooms New -0.9 -6 Zone -1.1 -Bedrooms New _0.9JA6 Zone1113edrooms New 0.9=A6 Zone -11 -Bedrooms New _0.1=A8 ZonelLCommoo_Areas New _0.9-A6 Zone_II_C.ommon_Areas New _0.9=A6 Zone_]Mommon- reas New 09_A6 Zone_I.I_Common-Area New _01_A8 Zone_I_V_RecreationBm New _0.9=A6 Zone_I_V_RecreationBm New .28=A4 Zone_I_V_RecreationRm New _09=A6 Zon. e_I_V_Recreation_Rm New _0.9=A6 Zone1V_Recreation_Rm New 0.9=A6 Zo.ne_I_VJ3ecreatio.n_Rm N .ew 0.9 _A6 Zone_MRecreatio.n_Rm EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY378-0206 Pape:3 of 18 Certificate Of Compliance: Residential (Part 2 of 3) CF -1 R LARRY & TERRIE OWENS .2/8/2006 Project Title Date FENESTRATION SURFACES # Type Insulation Area LI -Factor" SHGCZ True Azm. Cond. Tilt Stat. Glazing Type Location/ Comments _L 2 Window Lett Window Right (West)_9..0_ East) 64.0 _0...340 -NERC. _0..28 _NERC 0.340 NFRC 0_28 NFRC _2Z0_ 90 -90 NewB =-ER_B.UILTVinylJ.ow-E- 90 New BETTER BUILT Vinyl low E _ZcneJ_Master_B_edroom_ Zone I Master Bedroom 3 Window Right East 30.0 0.340 NFRC 0_28 NFRC 90 90 New BETTER BUILT Vinyl low E Zone I Master Bedroom 4 Window Rear Northeast 64.0 0.340 NFRC 0_28 NFRC 45 90 New BETTER BUILT Vinyl low E Zone I Master Bedroom 5 Window Front (South) 30.0 0.340 NFRC 0_28 NFRC 180 90 New BETTER BUILT Vinyl low E Zone II Bedrooms 6 Window Front (South) 30.0 0.340 NFRC 0_28 NFRC 180 90 New BETTER BUILT Vinyl low E Zone II Bedrooms 7 8 Window Window Front($outh) 30_0 Left (West) 12.0 0 340 NFRC 0.28 NFRC 0.340 NFRC 0.28 NFRC 180 270 90 New 90 New BETTER BUILT Vinyl low E BETTER BUILT Vinyl low E Zone II Bedrooms Zone II Bedrooms 6 1-0 11 12 Window Window Window Window Rear Front_($puth) Front Front (North) 48 0 30 0 (South) 12.0 (South) 48.0 _-0.3 NFRC 0.28 NFRC 03A0 NFRC0.28 NFRC 0.340 NFRC 0_28 NFRC 0.340 NFRC 0_28 NFRC 0 180 180 180 90 New 90 New 90 New 90 New BETTER BUILT Vinyl low E BETTER BUILT Vinyl low E BETTER BUILT Vinyl low E BETTER BUILT Vinyl low E Zone II Bedrooms Zone II Common Areas- rea11 Zone II Common Areas Zone II Common Areas 13 14 Window F_ro.nt_(.Sou.th) Window Rear 12.0 North) 96.0 0.3_40AER_ C 0,28-N_.F_RC 0.340 NFRC 0_28 NFRC t80_ 0 90 New BE-TT_ER_BUIL_T_V_in..yl_I.ow._E__Zone_I.I_CommonA_r_eas_ 90 New BETTER BUILT Vinyl low E Zone II Common Areas 15 Window Rear (North) 48.0 0.340 NFRC 0_28 NFRC 0 90 New BETTER BUILT Vinyl low E Zone II Common Areas 16 Window Left Northwest 20.0 0.340 NFRC 0_28 NFRC 315 90 New BETTER BUILT Vinyl low E Zone II Common Areas 17 Window Left (Northwest 48.0 0.340 NFRC 0_28 _NERC 315 90 New BETTER BUILT Vinyl low E Zone II Common Areas 18 Window Left (Wes) 96.0 0.340 NFRC 0_28 NFRC 270 90 New BETTER BUILT Vinyl low E Zone IV Recreation Rm 19 WlndQA Left_(Northwest) 24.0 0.340 NFRC 0_.28 NFRC 315_ 90 New BETTER BUILT Vinyl low E Zone IV Recreation Rm 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Insulation Condition Type Length R -Val. Location JA IV Reference Status Window 133 Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 2.0 2 . Bug Screen 0.76 8.0 8.0 8.0 0.1 8.0 8.0 3 Bug Screen 0.76 5.0 6.0 8.0 0.1 8.0 8.0 4 Bug Screen 0.76 -0-0 -&--0 14.0 0.1 0_0 0.0 5 Bug Screen 0.76 5.0 6.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 5_0 6_0 2.0 0. 2.0 2.0 7 Bug Screen 0.76 5.0 6.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 3.0 4.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 8.0 6.0 14.0 0.1 0.0 0.0 10 Bug Screen 0.76 5.0 6.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 6.0 2.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 6.0 2.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 8.0 12.0 14.0 0.1 0.0 0.0 15 Bug Screen 0.76 8.0 6.0 14.0 0.1 0.0 0.0 16 Bug Screen 0.76 4.0 6.0 14.0 0.1 0.0 0.0 17 Bug Screen 0.76 8.0 6.0 8.0 0.1 8.0 8.0 18 Bug Screen 0.76 8.0 12.0 8.0 0.1 8.0 8.0 19 Bug Screen 0.76 4.0 6.0 8.0 0.1 8.0 8.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Type Length R -Val. Location JA IV Reference Status Slab Perimeter 133 None No Insulation 26-A1 New Slab Perimeter 98 None No Insulation 26-A1 New Slab Perimeter 124 None No Insulation 26-A1 New Slab Perimeter 147 None No Insulation 26-A1 New Location/ Comments Zone I Master Bedroom Zone II Bedrooms Zone II Common Areas Zone IV Recreation Rm Run Initiation Time: 02/08/06 13.57.48 Run Code: 1139435868 EnergyPro 4.0 by Energysoft User Number: 5553 Job Number: ADY378-0206 Page:4 of 18 Certificate Of Compliance : Residential (Part 2 of 3) CF -1 R LARRY & TERRIE OWENS 2/8/2006 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments 20. Window Rear(N.orth)_9.6...0_—0-3.4.0_NERG-0-28 -NERC 0_ _9.0_ NewB.EIIERBUILT Viny]Jow._E__ZoneJV-Recreation Rm 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 8.0 12.0 28.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Tvoe Insulation R -Val. Location Condition Location/ JA IV Reference Status Comments Run Initiation Time: 02/08/06 13:57:48 Run Code: 1139435868 EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY378-0206 Page:5 of 18 Certificate Of Compliance: Residential (Part 3 of 3) CF -1 R LARRY & TERRIE OWENS Tank Energy Duct Duct 2/8/2006 Project Title Heating Cooling Location R -Value Status Date Ducted HVAC SYSTEMS Attic 8.0 New HVAC Split System Zri II Ducted Ducted Attic Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC Split System Zn I Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC Split System Zn II Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC Split System Zn III Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Ducts Tested? No No No WATER HEATING SYSTEMS Rated Tank Energy Duct Duct Condition Location Heating Cooling Location R -Value Status HVAC Split System Zn I Ducted Ducted Attic 8.0 New HVAC Split System Zri II Ducted Ducted Attic 8.0 New HVAC Split System Zn III Ducted Ducted Attic 8.0 New Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Ducts Tested? No No No WATER HEATING SYSTEMS Rated Tank Energy Standbyl'Tank Insul. Water Heater # in Input Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext. A.O. SMITH FPS -75-230 Small Gas No Pipe Insulation 1 75,000. 75 New 0.65 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length L Add 1/2" Control # HP Type In Plenum Outside Buried Insulation 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: MR. LARRY & MRS.TERRIE OWENS Address: 77-545 ROBIN RD. PALM DESERT. CA 92260 Telephone: 760-345-1889 Lic. #: 1p If_ C"— ' 2o� p n re) (date) Enforce ent Agency Name: Title/Firm: Address: Telephone: User Number: 5553 Documentation Author Name: ADRIANA GIL Title/Firm: Adriana Gil Address: 74-854 Velie Way Ste. #8 Palm Desert CA 92260 Telephone: - 6 404-7917 O (signature) (date) (signature/stamp) (date) Certificate Of Compliance : Residential (Addendum) CF -1 R LARRY & TERRIE OWENS 2/8/2006 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the xuv4uacy VI URI APMA41 JUbL111GC1u W11 arw UUGurI1U"Ld1uOrt SUUMIEWO. Plan Field The Roof "R-38 Roof (R.38.2x4.24)" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- �rrr '. U orr'-M Lca "U a114/VI YCIIIIbalIV11111Culwa Q11u 111Usl oe repvriea on cne %.r -arc installation certificate. Plan Field EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY378-0206 Paae:7 of 18 1 Mandatory Measures Summary: Residential (Page 1 of 2) ' MF -1 R NOTE: Low-rise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercedes the items marked with and asterisk (`) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not applicable. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑X ❑ e§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑X ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ a ❑ apply to exterior mass walls). ❑ ❑X ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. Q ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ ❑X ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑X ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑X ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑X ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor 0 ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑X ❑ ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ElElCF-6R Form: ❑X ❑ ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑X ❑ Coefficient (SHGC), and infiltration certification. ❑ ❑X ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑X . ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑X ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑X ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑X ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑X ❑ and wind. 6. Insulation for chilled water piping and'refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑X ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑X ❑ EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY378-0206 Page:8 of 18 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. NIA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑X❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating x❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ § 114: Pool and Spa Heating Systems and Equipment ❑X LE 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑X ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ® ❑ ❑ b. Cover for outdoor pools or outdoor spas. X❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. X❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ © ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteriaX❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ X❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ x❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ X❑ ❑ OR are controlled by an occupant sensor(s) ceritfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑X ❑ controlled by an occupant sensor that complies with Section 1) 9(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑x ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ x❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑X ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑X ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY378-0206 Page:9 of 18 Residential Kitchen Lighting Worksheet WS -5R LARRY & TERRIE OWENS 2/8/2006 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts U 26w Compact Fluorescent Triple 4 Pin Yes X No F 37.0 x 8 = 296 or 40w Recessed Incandescent Yes X1 No 1 40.0 x 7 = 280 or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 576 B: 0 COMPLIES IF A z B YES G- NO ❑ I EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY378-0206 Page:10 of 18 1 WAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE LARRY & TERRIE OWENS 2/8/2006 SYSTEM NAME FLOOR AREA HVAC Split System Zn 1 1,436 YSTEM Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLINGPEAK COIL HTG. PEAK CFM ISensiblel Latent I I CFM I Sensible 858 14,750 2,701' 459 17,532 0 2,018 1,920 0 0 0 0 0 0 0 0 0 2,018 1 1,920 18,786 2,701 21,373 York H4DH048/P3HUB16LO65 U&H 31,543 11,120 65,000 Total Adjusted System Output 31,543 11,120 65,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 1HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26.0 OF 68.9 OF 68.9 OF 107.0 OF O Supply Air Ducts Outside Air 0 cfm 105.9 °F Supply Fan Heating Coil 1600 cfm ROOMS 68.9 OF 70.0 °F �% Return Air Ducts 4 1000LING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) 11.0 / 77.6 OF Outside Air 0 cfm 77.2/64.6 °F 77.2 / 64.6 OF 77.2/ 4.70F 0 58.7/57.70F Supply Fan 1600 cfm Cooling Coil �% Return Air Ducts 4 Supply Air Ducts 59.8/58.1°F 53.3% R.H. ROOMS 76.0 / 64.3 OF EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY378-0206 Page: 11 of 18 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE LARRY & TERRIE OWENS 2/8/2006 SYSTEM NAME FLOOR AREA HVAC Split System Zn II 1,706 Number of Systems I 1I Heating System Output per System 65,000 Total Output (Btuh) 65,000 Output (Btuh/sqft) 38.1 Cooling System Output per System 58,500 Total Output (Btuh) 58,500 Total Output (Tons) 4.9 Total Output (Btuh/sgft) 34.3 Total Output (sgft/Ton) 349.9 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sqft) 1.17 Airflow (cfm/Ton) 410.3 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS 26.0°F 69.1°F 69.1°F Outside Air 0 cfm 69.1 of 11.0 / 77.6 of Outside Air 0 cfm 76.9 / 65.0 °F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent 11CFM1Sensible 850 14,123 3,058 540 16,575 0 1,932 1,815 0 0 0 0 0 0 0 0 0 1,9321 1,815 17,9861 3,058 York H4DH060/PDHUCO20L60 U&H 37,098 15,206 Total Adjusted System Output (Adjusted for Peak Design Conditions) 1 37,098 15,206 Supply Fan Heating Coil 2000 cfm 76.9/65.0°F TIME OF SYSTEM PEAK I Aug 2 pm 99.7 of res at Ti k Return Air Ducts; 76.9 / 65.1°F . 59.5 / 58.5 of Supply Fan Cooling Coil 2000 cfm h Return Air Ducts `; 20,206 65,000 65,000 Jan 12 am Supply Air Ducts 98.8 of ROOMS 70.0 OF Supply Air Ducts 60.4/58 . 9 of 54.9% R.H. ROOMS 76.0 / 64.7 OF EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY378-0206 Page: 12 of 18 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE LARRY & TERRIE OWENS 2/8/2006 SYSTEM NAME FLOOR AREA HVAC Split System Zn III 1,380 1HEATING SYSTEM PSYCHROMETRICS (Airst 26.0 of 68.8 of 68.8 of m Outside Air 0 cfm 68.8 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM Sensible 1,292 21,063 2,627 486 18,507 0 2,881 2,027 0 0 0 0 0 0 0 0 0 2,881 2,027 26,825 2,627 22,56 York H4DH048/P3HUB16LO65 U&H 31,848 11,029 65,000 Total Adjusted System Output 31,848 11,029 65,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK L Aug 2 pm Jan 12 am 107.0 of Supply Fan Heating Coil 1600 cfm at Time of Supply Air Ducts 105.8 of ROOMS 70.0 of Return Air Ducts I (COOLING SYSTEM PSYCHROMETRICS (Airstream Temaeratures at Time of Coolina Peak1 11.0 177.6 OF 77.7 / 64.9 OF 77.7 / 65.0 OF. 59.0 / 58.0 OF — � Outside Air 0 cfm Supply Fan 1600 cfm 77.7/64.9 of Cooling Coil h Return Air Ducts '� Supply Air Ducts 60.7 / 58.6 of 53.8% R.H. ROOMS 76.0 / 64.4 of EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY378-0206 Paae:13 of 18 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE LARRY & TERRIE OWENS 2/8/2006 SYSTEM NAME FLOOR AREA HVAC Split System Zn IV 1,778 Number of Systems 1 Heating System Output per System 65,000 Total Output (Btuh) 65,000 Output(Btuh/sgft) 36.6 Cooling System Output per System 58,500 Total Output (Btuh) 58,500 Total Output (Tons) 4.9 Total Output (Btuh/sgft) 32.9 Total Output (sgft/Ton) 364.7 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.12 Airflow (cfm/Ton) 410.3 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions :ATING SYSTEM PSYCHRO 26.0 OF 68.9 of 17 Outside Air 0 cfm L vl� Supply Fan 2000 cfm 68.9 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK 1COILHTG.PEAK CFM ISensiblel Latent CFM I Sensible 1,057 17,166 3,154 702 21,194 0 2,348 2,321 0 0 0 0 0 0 0 0 0 2,348 2,321 21,862 3,154 25,837 York H4DH060/PDHUCO20L60 U&H 37,166 15,278 65,000 Total Adjusted System Output 37,166 15,278 65,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am RICS (Airstream Temperatures at Time of He 68.9 OF 99.4 OF Heating Coil Return Air Ducts Supply Air Ducts 98.4 of ROOMS 70.0 OF [COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) 111.0 / 77.6 of 77.1 / 65.2 of 77.1 / 65.2 of . 59.6 / 58.7 OF Outside Air 0 cfm 77.1/65.2 °F Supply Fan Cooling Coil 2000 cfm Return Air Ducts Supply Air Ducts 60.7/59.1OF 55.2% R.H. R00:M7S71 76.0/64.8OF EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY378-0206 Page: 14 of 18 ROOM LOAD SUMMARY PROJECT NAME LARRY & TERRIE OWENS DATE 2/8/2006 SYSTEM NAME HVAC Split System Zn 1 FLOOR AREA 1,436 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone I Master Bedroom Zone I Bdrms. 1 858 14,750 2,701 858 14,750 2,701 459 17,532 PAGE TOTAL 1 858 14,750 2,701 459 17,532 TOTAL 1 858 14,750 2,70111 459 17,532 EnergyPro By EnergySoft User Number: User Job Number: ADY378-0206 Page: 15 of 18 ROOM LOAD SUMMARY ' PROJECT NAME LARRY & TERRIE OWENS DATE 2/8/2006 SYSTEM NAME HVAC Split System Zn II FLOOR AREA 1,706 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone II Bedrooms Zone II Besdrooms 1 850 14,123 3,058 850 14,123 3,058 540 16,575 PAGE TOTAL 1 850 14,123 3,058 540 16,575 TOTAL 1 850 14,123 3,058 540 .16,575 EnergyPro By EnergySoft User Number: User Job Number: ADY378-0206 Page: 16 of 18 ROOM LOAD SUMMARY PROJECT NAME DATE LARRY & TERRIE OWENS 2/8/2006 SYSTEM NAME FLOOR AREA HVAC Split System Zn 111 1,380 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone II Common Areas Zone II Common Areas 1 1,292 21,063 2,627 1,292 21,063 2,627 486 18,507 PAGE TOTAL 1 1,292 21,063 2,627 486 18,507 TOTAL 1 1,292 21,063 2,62711 486 18,507 EnergyPro By EnergySoft User Number: User Job Number: ADY378-0206 Page:17 of 18 ROOM LOAD SUMMARY PROJECT NAME LARRY & TERRIE OWENS _ DATE 2/8/2006 SYSTEM NAME HVAC Split System Zn IV FLOOR AREA 1,778 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENTCFM SENSIBLE LATENT CFM SENSIBLE Zone IV Recreation Rm Zone IV Recreation Rm. 1 1,057 17,166 3,154 1,057 17,166 3,154 702 21,194 PAGE TOTAL 1 1,057 17,166 3,154 702 21,194 TOTAL 1 1,057 17,166 3,154 702 21,194 EnergyPro By EnergySoft User Number: User Job Number: ADY378-0206 Pagel8 of 18 TITLE 24 REPORT Title 24 Report for: LARRY & TERRIE OWENS y(CASITA) 81-900 MOUNTAIN VIEW LN. LA QUINTA, CA Project Designer: MR. LARRY & MRS.TERRIE OWENS 77-545 ROBIN RD. PALM DESERT, CA 92260 760-345-1889 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPRQVE FOR CONST CTIi N DA 2 port Prepared By: ADRIANA GIL Adriana Gil 4-854 Velie Way Ste. #8 Palm Desert, CA 92260 (760) 404-7917 Job Number: ADY379-0206 Date: 2/8/2006 FEB 14 2006 IU The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.0 by EnergySoft Job Number: ADY379-0206 User Number 5553 TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary Room Load Summary 1 2 3 7 9 10 EnergyPro 4.0 by EnergySoft Job Number: ADY379-0206 User Number: 5553 Certificate Of Compliance: Residential (Part 1 of 3) CF -1 R _LARB_l(_&_T_E.RRIE QWFN.S_(CAS.I_TA) 248/2QQ6 Project Title (XJ Single Family ❑ Addition Total Conditioned Floor Area: 970 ft2 Date _8J,98-0-M-0-UNT A I.N_V_LE_W_ _LN._LA_Q_U_1-N-TA n/a ft2 Project Address 0 ft2 Building Permit # A_ driana-GSI (760)404-7917 Fenestration: Author Telephone Plan Check/Date -Ener_�gVP o Compli rice Method 15 Climate Zone Ratio: Field Check/Date Source Energy Use Standard Proposed Compliance Vent (kBtu/sf-yr) Design Design Margin Hgt. Area Space Heating 1.80 0.52 1.28 _2 -n1a Space Cooling 70.56 70.32 0.23 Type Frame Fans 10.65 10.64 0.01 .RO.O.i- Wood- Domestic Hot Water 18.43 15.78 2.65 Wall_ Wood_ Pumps 0.00 0.00 0.00 Wall_ Wood_ Totals 101.44 97.27 4.17 Percent better than Standard: 4.1% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRE Building Type: (XJ Single Family ❑ Addition Total Conditioned Floor Area: 970 ft2 ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (South)180 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 970 ft2 Fenestration: Average Ceiling Height: 8.0 ft Area: 249 ft2 Avg. U: 0.34 Number of Dwelling Units: 1.00 Ratio: 25.7% Avg. SHGC: 0.28 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area .EiV.AC_SplitSystern 9.7.0 _7_760 1_00_ Conditioned- -Setback- _2 -n1a OPAQUE SURFACES Insulation Act. Gains Condition Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y / N Status JA IV Reference Location / Comments .RO.O.i- Wood- 97.0_ _0_026_ -R=38_ _R=0_.0_ -9.0_ 1.8 X1 ❑ New _01LA8 Guestl3ouse Wall_ Wood_ 25.6_ _0_.0.6.9_ _&21 _R=0.0_ 1.8.0__9.0 X ❑ N.ew -09--A- 6 Gu.estliouse Wall_ Wood_ 1.89_ _0._0.6.9_ _R21. _R=0_0_ _2.7.0__90 X ❑ New 0.9=A6 G.u.esLHouse Wall_ Wood_ 391. _0_069_ -R=21. _R=0..0_ 0__9.0 DK ❑ New 0.9=A6 Guest -House Wall_ Wood_ 28.0_ _0..0.6.9_ -R=21. -R0-0- _90__9.0 [X E]N.ew 09=A6 G_uest-E ouse EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY379-0206 Paw:3 of 10 1 Certificate Of Compliance: Residential (Part 2 of 3) CF -1 R LARRY & TERRIE OWENS (CASITA) 2/8/2006 Project Title Date FENESTRATION SURFACES Window Inside Cond. R -Val. Overhang Left Fin Right Fin # Exterior Shade Tvpe SHGC Hgt. Wd. True Cond. REM. Dist. Len. Hgt. Dist. Len. Hgt. Location/ # Type Area U-Factorl SHGCZ Azm. Tilt Stat. Glazing Type Comments _1- Window F_ront_(.S.outh)_9.6_0_ '0..3.4.0-NF_BC _0..28 _NF_PIC 1.8.0_ _9.0- New -BET -TER -BUJ L -T -Vi ayl-low-E- Guestriouse 2 Window Front South) 48.0 0.340 NFRC 0_28 NFRC 180 90 New BETTER BUILT Vinyl low E Guest House 3 Window Left (Wes) 96.0 0.340 NFRC 0_28 NFRC 270 90 New BETTER BUILT Vinyl low E Guest House 4 Window Rear North) 9.0 0.340 NFRC 0_28 NFRC 0 90 New BETTER BUILT Vinyl low E Guest House 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1166. INTERIOR AND EXTERIOR SHADING Window Inside Cond. R -Val. Overhang Left Fin Right Fin # Exterior Shade Tvpe SHGC Hgt. Wd. Len. Hgt. LExt. REM. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 8.0 12.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 8.0 12.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 3_0 3-0 2.0 Q. 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Type Area Thick. Heat (so (in.) Cap. Inside Cond. R -Val. JA IV Reference Condition Status Location/ Comments Concrete, Heavyweight 970 3.50 28 0_98 0 26-A1 New Guest House / Slab on Grade PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 136 None No Insulation 26-A1 New Guest House Run Initiation Time: 02/08/06 16:04:07 Run Code: 1139443447 EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY379-0206 PageA of 10 Certificate Of Compliance : Residential (Part 3 of 3) CF -1 R LARRY & TERRIE OWENS (CASITA) 2/8/2006 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC Split System Central Furnace 80% AFUE Split Air Conditioner 14.5 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Location Heating Coolinq Location R -Value Status HVAC Split System Ducted Ducted Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Attic 8.0 New Ducts Tested? No WATER HEATING SYSTEMS Rated l Tank Energy Standbyl Tank Insul. Water Heater # in Input Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext. A.O. SMITH FPS -50-224 Small Gas No Pipe Insulation 1 43,000 50 New 0.65 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (f Add 1/2" Control # HP Type In Plenum Outside Buried Insulation 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: MR. LARRY & MRS.TERRIE OWENS Address: 77-545 ROBIN RD. PALM DESERT, CA 92260 Telephone: 760-345-1889 A nt Agency Name: Title/Firm: Address: Telephone: Documentation Author Name: ADRIANA i Title/Firm: Adriana Gil Address: 74-854 Velie Way Ste. #8 Palm Desert, CA 92260 Telephq e: 760 404-7917 (signature) (date) Certificate Of Compliance : Residential (Addendum) CF -1 R LARRY & TERRIE OWENS (CASITA) 2/8/2006 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the wcyua..r - W spe�aJusunUauWn anu uucwnenwuun suunoaeu. Plan Field The Roof "R-38 Roof.(R.38.2x4.24)" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. HIGH MASS Design - Verify Thermal Mass: 970 sqft Exposed Slab Floor, 3.50" thick at Guest House HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- ann.nvarl W CDC n ,;An .. /`Cf` A ......:........di.... .:c__.:__ �rr•�•�� ••—•• 11 . •�• ..�...y ••�•• arrl•••V•• .� L...0 anuwi vernuwuc)n meuwus anu rnusi oe repor[eu on zne Vr-4rc installation certificate. Plan Field EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY379-0206 Pape:6 of 10 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Low-rise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercedes the items marked with and asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not applicable. NIA DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑X ❑ �§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: Q ❑ ❑ *§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ FX] ❑ apply to exterior mass walls). ❑ ❑X ❑ �§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑X ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ ❑X ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑X ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑X ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑X ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑X ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑ ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. ❑X ❑ ❑ 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑X ❑ ❑ Coefficient (SHGC), and infiltration certification. ❑ ❑X ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ Q ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑X ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑X ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑X ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑X ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑X ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑X ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑X ❑ EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY379-0206 Page:7 of 10 Mandatory Measures Summary: Residential (Page 2 of 2) * MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the, requirements of the CMC Sections 601, 602, 603, 604, ❑ Q ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181,.UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑X ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑X ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ® ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ ® ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the X❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. © ❑ ❑ b. Cover for outdoor pools or outdoor spas. 0 ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑X ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria Q ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑X ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑x ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑X ❑ OR are controlled by an occupant sensor(s) ceritfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑X ❑ controlled by an occupant sensor that complies with Section 1`19(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑X ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.X❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more Fx] ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY379-0206 Page:8 of 10 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE LARRY & TERRIE OWENS CASITA 2/8/2006 SYSTEM NAME FLOOR AREA HVAC Split System 970 Number of Systems 1 Heating System Output per System 64,000 Total Output (Btuh) 64,000 Output (Btuh/sqft) 66.0 Cooling System Output per System 30,200 Total Output (Btuh) 30,200 Total Output (Tons) 2.5 Total Output (Btuh/sgft) 31.1 Total Output (sgfUTon) 385.4 Air System CFM per System 1,000 Airflow (cfm) 1,000 Airflow (cfm/sgft) 1.03 Airflow (cfm/Ton) 397.4 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 of 68.3 of Outside Air 0 cfm Supply Fan 1000 cfm 68.3 of RICS 68.3 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 796 14,329 2,084 271 16,387 0 1,960 1,795 0 0 0 0 0 0 0 0 0 1,960 1,795 18,249 2-0784 19 976 York H4TS030/P1DUA12VO64VSPD 21,930 4,690 64,000 Total Adjusted System Output 21,930 4,690 64,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2m Jan 12 am eam Temperatures at Time of Heatina Peak) 128.5 of Heating Coil �% Return Air Ducts 4 Supply Air Ducts 126.8 of ROOMS 70.0 of DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.6 OF 77.8 / 64.10F 77.8 / 64.2 OF 57.2 / 56.1 OF O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 59.1 / 56.8 of 1000 cfm 50.8% R.H. ROOMS 77.8/64.10F 76.0/63.5OF h Return Air Ducts 11 EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY379-0206 Paae:9 of 10 1 ROOM LOAD SUMMARY PROJECT NAME LARRY & TERRIE OWENS CASITA DATE 2/8/2006 SYSTEM NAME HVAC Split System FLOOR AREA 970 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Guest House Guest House 1 796 14,329 2,084 796 14,329 2,084 271 16,387 PAGE TOTAL 1 7961 14,329 2,084 271 TOTAL 1 796 14,329 2,084 11 271 16,387 16,387 EnergyPro By EnergySoft User Number: User Job Number: ADY379-0206 Page: 10 of 10 �.a-�'TemporaryCertificate of ° Occupancy Lrwasowhn �.�� • ��I%I�� ot OF 119w Building & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at. the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 81960 MOUNTAIN VIEW LANE Use classification: SFD Building Permit No.: 05-5588 Occupancy Group: R3U1 Type of Construction: VN Land Use Zone: RL Owner of Building: LARRY OWENS Address: 77 545 ROBIN RD. City, ST, ZIP: PALM DESERT CA 92211 By: D. GATICA Date: 3-6-2007/EXPIRES 4-6-2007 Building Official POST IN A CONSPICUOUS PLACE