Loading...
BRES2015-037578-495 CALLE.TAMPICO LA QUINTA, CALIFORNIA 92253 CO Application Number: BRES2015-0375 Property Address: 81255 NATIONAL DR APN: 767500012 Application Description: HAZELRIGG / ADDTION 56J Property Zoning: Application Valuation: $50,000.QO Applicant: ST PETER CONSTRUCTION 8527 CALLE CARABE ST RANCHO CUCAMONGA, CA 91730 T- D VOICE (760) 777-7125 . FAX (760) 777-7011 A DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 D BD RMIT UDate: 6/10/2016 Juiv Owner: II ZO'h ARLENE HAZELRIGG 0 ^ CITY n _ `� 5 VISTA LUCI f- 1r��5bI�D}J�7G�( Q,fjljl� TE NEWPORT COAST, CA 92253 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B ' `License No.: 793946 D ate: —1 b `�' hntractor: • OWNER -BUILDER DECLARA I hereby affirm under penalty of perjury that I amiexempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_J I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (� I am exempt under Sec. B.&P.C. for this reason r Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's N Lender's Add Contractor: ST PETER CONSTRUCTION 8527 CALLE CARABE ST RANCHO CUCAMONGA, CA 91730 (909)518-9463 LIC. No.: 793946 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier:— Policy Number: _ I certify that in the performance of the work for -which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. D Atte: l� �(� -� 6 �pRlicant: /1 < WARNING: FAILURE TO SECURE WORKERS'COMPENSAQ COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDG EM ENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes, null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction; and hereby authorize representatives of this city to enter upon the, above-mentioned property for inspection purposes. Ake? //V -lD' f 6 Sig�e (Applicant or Agent DESCRIPTION "" °ACCOUNT ':� =jQTY `PAID PAID'DATE .AMOUNT ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83 $120:83 6/10/16 > zPAID"BY METHOD RECEIPT # CHECK #. CLTD BY ST PETER CONSTRUCTION CHECK MR310 7141 MFA DESCRIPTION - ACCOUNT - QTY AMOUNT' - PAID' PAID DATE' ADDITION, FIRST 100 SF PC 101-0000-42600 ' 0 $171.14 $171.14 6/10/16 PAID BY METHOD s RECEIPT #M CHECK # CLTD BY , ST PETER CONSTRUCTION CHECK MR310 7141 MFA Total Paid for ADDITION:. $291.97 $291.97 DESC ;. x•,'., RIPTION'.' ;, c ` ACCOUNT -:CI,TY� AMOUNT PAID "' PAID DATE r , HOURLY PLAN CHECK - YES 101-0000-42600 1.5 $105.00 $105.00 6/10/16 PAID`BY t ti METHOD , #';yw CHECK # CLTD BYE s x.. -RECEIP? ST PETER CONSTRUCTION CHECK MR310 .7141 MFA DESCRIPTION ' * ACCOUNT "' ;QTY' -AMOUNT' PAID PAID DATE{ HOURLY PLAN CHECK - YES 101-0000-42600 1.25 $87.50 $87.50 6/10/16 PAID BY METHOD L` -:RECEIPT # CHECK # CLTD BY y^, ST PETER CONSTRUCTION CHECK MR310 7141 MFA Total Paid for BLDG CITY STAFF - PER HOUR: $192.50 $192.50 h 'DESCRIPTION ; ,''R ACCOUNT - QTYh AMOUNT 'PAID PAID<DATEF <w BSAS S61473 FEE 101-0000-20306 0 $2.00 $2.00 6/10/16 r " PAID BY ''` METHOD ;RECEIPT # <; CHECK # CLTD BY, .' ST PETER CONSTRUCTION CHECK MR310 7141 MFA Total. Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 $2.00 � ; ?x ACCOUNT QTY AMOUNT> :'- KPAID PAID:DATE ":DESCRIPTION Y RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 $145.03 6/10/16, 'PAID`BYMETHOD a :'RECEIPT # CHECK #- CLTD BY ST PETER CONSTRUCTION CHECK MR310 7141 MFA DESCRIPTION ' "' ACCOUNT QTY . AMOUNT- PAID PAID DATE- , RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.86 $47.86 6/10/16 PAID BY twf= n { , R " METHOD syr` ~RECEIPT # 'CHECK # y x -CLTD BY ST PETER CONSTRUCTION CHECK MR310 7141 MFA Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89. DESCRIPTION ACCOUNT Y ` QTIf < AMOUNT ''- wPAID ;' PAID DATE` APPLIANCE REPAIR/ALTERATION 101-0000-42402 0 $12.09 $12.09 6/10/16 PAID'BY ¢ 'METHOD ., >RECEIPT # CHECK # '. CLTD BY„:• „ .., . �_.:. 2 ,,... ST PETER CONSTRUCTION CHECK MR310 .7141 MFA t 5.•DESCRMTION e'a° M ACCOUNT QTY ` AMOUNT” ` Y PAID ,. PAID DATE �� . APPLIANCE REPAIR/ALTERATION PC 101-0000-42600 0 $4.83 $4.83 6/10/16 PAID BY v�. , METHOD`, , a�RECEIPT #'�# �,� CHECK # CLTD BY, �� ST PETER CONSTRUCTION CHECK .- MR310 ' 7141 MFA Total Paid for MECHANICAL: $16.92 $16.92 DESCRIPTION ACCOUNTri r QTY. ` AMOUNT J `` PAID ,r PAID'.:DATE> -SMI : RESIDENTIAL 101-0000-20308 0 $6.50 $6.50 6/10/16 PAID BY, "� aJ A t. t METHOD tr ':RECEIPT #'' y k r CHECK # 'CLTD BY ST PETER CONSTRUCTION CHECK MR310 7141 MFA Total Paid for STRONG MOTION INSTRUMENTATION SMI: $6.50 $6.50 TOTALS: Description: HAZELRIGG / ADDTION 56SQ FT AND SLIDING DOOR IN MASTER Type: BUILDING, RESIDENTIAL Subtype: ADDITION Status: ISSUED Applied: 9/18/2015 SKH Approved: 1/6/2016 JJO - Parcel No: 767500012 Site Address: 81255 NATIONAL DR LA QUINTA,CA 92253 Subdivision: TR 29657 Block: Lot: 26 - Issued: 6/10/2016 MFA Lot Scl Ft: 0 Building Scl Ft: 0 Zoning: Finaled: Valuation: $50,000.00 Occupancy Type: Construction Type: Expired: 12/7/2016 MFA No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details:- 56 SQ. FT. MASTER BEDROOM ADDITION W/ SLIDING DOORS. PER 2013 CRC CODES ' ,� . '�..I APPlied to Approved ` Approved to Issued �� = . Printed: Friday, June 10, 2016 3:36:18 PM 1 of 4 sysreres CHRONOLOGY ~ `I -C TYPE," '_, c STAFF NAME - ACTION:DATE ,r } CO4kETION,' ATE• ' T''* _ x.'.,.,,NOTES. , a �r - _ .� •.. ,. Jr �.. ,, �.-. NOTE JIM JOHNSON 10/1/2015 ` 10/7/2015 PLAN CHECK COMMENTS FROM CONSULTANT KAY HENSEL' 10/7/2015 10/7/2015 STRUC RFC - 10/6/2015 RECEIVED PLAN CHECK COMMENTS FROM CONSULTANT KAY HENSEL 1/6/2016 1/6/2016 _ `STRUC APPROVABLE 1/5/2016 RECEIVED PLAN CHECK PICKED UP STEPHANIE GUMPERT 10/8/2015 10/8/2015 PLANS PICKED UP BY BARRY PLAN CHECK SENT TO KAY HENSEL 12/18/2015 12/18/2015 STRUC TO YOUNG'- DUE AFTER 1/4/2016 OUTSIDE PC PLAN CHECK SUBMITTAL 'MARY FASANO 12/18/2015 12/18/2015. RECEIVED Printed: Friday, June 10, 2016 3:36:18 PM 1 of 4 sysreres PLAN CHECK SUBMITTAL STEPHANIE KHATAMI 9/18/2015 INFORMATION 9/18/2015 RECEIVED DESCRIPTION'` ACCOUNT; QTY "AMOUNT: PAID"' PAID DATE RECEIPT #; ' CHECK # METHOD,,PAID _.. BY CALLED BARRY TO INFORM HIM THE PLANS ARE READY FOR TELEPHONE CALL w JIM JOHNSON 10/7/2015 ADDITION, FIRST 100 SF 10/7/2015 0 $120.83 $120.83 6/10/16 MR310 7141 CHECK ST PETER MFA CORRECTIONS CONSTRUCTION CALLED BARRY ST. PETER TO INFORM HIM PLANS ARE READY TELEPHONE CALL 101-0000-42600 JIM JOHNSON 1/6/2016 $171.14 6/10/16 1/6/2016 7141 CHECK ST PETER MFA PC TO ISSUE. CONSTRUCTION CONDITIONS Total Paid for ADDITION: p.:_ .... CONDITI 'N r a ` .i DATE DATE. ;DATE sCONTACT- " �SATISfIED STATUS REMARKS _ w „NOTES z't IYPEr i ,ADD.ED _ RE Q UIRED :.. �,,, $105.00' .'. READY TO ISSUE 7141 CHECK ST PETER MFA YES JIM JOHNSON 1/6/2016 PENDING HOA LETTER REQUIRED CHECKLIST CONSTRUCTION CONTACTS NAME TYPE �, ° ., NAME ADDRESSi` CITY .x 'STATE T ZIP: -PHONE-;, FAX : �� EMAIL APPLICANT ST PETER CONSTRUCTION. 8527 CALLE CARABE ST RANCHO CA 91730 CUCAMONGA , CONTRACTOR ST PETER CONSTRUCTION 8527 CALLE CARABE ST RANCHO CA 91730 CUCAMONGA OWNER ARLENE HAZELRIGG 5 VISTA LUCI NEWPORT CA 92253 COAST Printed: Friday, June 10, 2016 3:36:18 PM 2 of 4 SYSTPAAS FINANCIAL INFORMATION DESCRIPTION'` ACCOUNT; QTY "AMOUNT: PAID"' PAID DATE RECEIPT #; ' CHECK # METHOD,,PAID _.. BY w ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83 $120.83 6/10/16 MR310 7141 CHECK ST PETER MFA CONSTRUCTION ADDITION, FIRST 100 SF 101-0000-42600 0 $171.14 $171.14 6/10/16 MR310 7141 CHECK ST PETER MFA PC CONSTRUCTION Total Paid for ADDITION: $291.97 $291.97 HOURLY PLAN CHECK _ 101-0000-426001:5 $105.00 $105.00' 6/10/16 MR310 7141 CHECK ST PETER MFA YES CONSTRUCTION Printed: Friday, June 10, 2016 3:36:18 PM 2 of 4 SYSTPAAS INSPECTIONS PARENT PROJECTS Printed: Friday, June 10, 2016 3:36:18 PM 3 of 4 srsrc•rns � "RECEIPT,# METHOD DESCRIPTION: ¢ -. ACCOUNT k' QTY AMOUNT i< ` —PAID PAID.DATE CHECK # n X : . .. K �c •. v +� •, .:.' a :;.. •: .,..fix -au _('; %la+y�Y �, HOURLY PLAN CHECK;.. 101=0000-42600 1.25 $87.50 $87.50 6/10/16 MR310 7141 CHECK ST PETER MFA YES CONSTRUCTION Total Paid for BLDG CITY STAFF - PER HOUR: $192.50 $192.50 BSAS SB1473 FEE 101-0000-20306 0 $2.00 $2.00 6/10/16 MR310 7141 CHECK ST PETER MFA CONSTRUCTION Total Paid for BUILDING STANDARDS ADMINISTRATION $2.00 $2.00 BSA: RESIDENTIAL, FIRST 101-0000-42403- 0 $145.03 $145.03 6/10/16 MR310 7141 CHECK ST PETER MFA 1,000SF CONSTRUCTION RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 $47.86 6/10/16 MR310 7141 • CHECK ST PETER MFA 1,000SF, PC CONSTRUCTION Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89 APPLIANCE 101-0000-42402 0 $12.09 $12.09 6/10/16 MR310 7141 CHECK ST PETER MFA REPAIR/ALTERATION - CONSTRUCTION APPLIANCE 101-0000-42600 0 $4.83 $4.83 6/10/16 MR310 7141 CHECK ST PETER MFA REPAIR/ALTERATION PC CONSTRUCTION Total Paid for MECHANICAL: $16.92 $16.92 SMI - RESIDENTIAL 101-0000-20308 0 $6.50 $6.50 6/10/16 MR310 7141 CHECK ST PETER MFA CONSTRUCTION Total Paid for STRONG MOTION INSTRUMENTATION SMI: $6.50 $6.50 TOTALS:1$702.78 INSPECTIONS PARENT PROJECTS Printed: Friday, June 10, 2016 3:36:18 PM 3 of 4 srsrc•rns IST BLDG STR (2 YOUNG 9/18/2015 10/2/2015 10/6/2015 REVISIONS REQUIRED WK) ENGINEERING 1ST BLDG NS (2 WK) JIM JOHNSON 12/18/2015 1/7/2016 1/6/2016 APPROVED 1ST BLDG STR (2 JOHN 12/18/2015 1/7/2016' 1/4/2016 READY FOR APPROVAL WK) THOMPSON "„ .Mt +.....•.. ..,-..- > `v 'CREATED. `` . � OWNER . _ ,. k.,;.- DESCRIPTIONS wv:,�;3•..r,"j PATHNAME x.y_ ~ "„ .Mt +.....•.. ..,-..- > `v 'CREATED. `` . � OWNER . _ ,. k.,;.- DESCRIPTIONS wv:,�;3•..r,"j PATHNAME x.y_ ~ v > y:SUBDIR ETRAKMENABLED' _. .�:_. _,..'�5 "a""...i .:Y'; '. +....,.. n _�.. y -!lment Types _ SCHOOL FEES BRES2015- SCHOOL FEES BRES2015- DOC 10/1/2015 JIM JOHNSON 0375.pdf 0375.pdf 0 81-255 NATIONAL 81-255 NATIONAL DOC 10/7/2015, JIM JOHNSON DR..docx DR..docx 0 2ND REVIEW - .2ND REVIEW - DOC 1/4/2016 JOHN THOMPSON, STRUCTURAL STRUCTURAL 0 TRANSMITTAL.pdf TRANSMITTAL.pdf - ` 1ST REVIEW - gRES 2015 0375 KS DOC - 10/6/2015. KATHRYN SAMUELS STRUCTURAL (ist).doc 0 COMMENTS 1ST REVIEW - NEW CITY DOC 10/6/2015 KATHRYN SAMUELS STRUCTURAL TRANSMITTAL BRES - 0 " TRANSMITTAL 2015-0375 (ist).pdf Printed: Friday, June 10, 2016 3:36:18 PM 4 of 4 SYSTEAAS SEP 1 8 2015 CITY OF LA QUINTA COMMUNITY DEVFLOPMEIVT Bui(dtn.g 81 Saf etyDfvlsion .. P.O. Box 1504,78-495 Caffe Tampico 4.Quhlta, CA 92253 -:(760) 777-7012 Building Permit Application' and Tracking Sheet Permit # T2- ProjectAddress: S (a SS--ivq'MOt0 AL_ �'FA- Name:. !� JC 0,4-2.&4g/jam, (6. A. P. Number. '767 J O oo ' 10 — g (ate — t.) A�-t' b n9 A-L. V Legal Description SPiQ • ,. Zap: LA Qu (kiTA C A- �i 2 zu Contractor. 5 j - eT Co.ki S I Pj (TT( .ON Telephone: Rq / -339, R3 q3 ProjectDescription: :5ip P—OC)H ff �j) /DlCI Address: �01%^ CL(� ���E City, H, ZiP&*H CUCA HOAJ eA4- L7 `73(� Hr4 STE/z $El Rcw- � SLjDic�b O Telephone: J I SS g 3 State Lia #: %R (7 (�� City Lic #; Arch., Engr., Designer K � Il7 , . D C� l � til Address: 41q 8a �, Afz o City, ST. Zip: YU L l 1U D fi C A- - Telephone: State Lia #: Name of Con= Person:/5`r _ �(' �i( Construction Type: t,A90 D Occupancy: z - l f -- Project type (circle one): ew Add'n Alter Repair Demo Sq. Ft : S'� # Stories: #Units Estimated Value of Project: 50, D CO Telephone # of Contact Perm�: (�� 5 %5,� ice. APPLICANT: DO NOT WRITE BELOW THIS UNE tR Submittal RWd Reed TRACMG PERMIT FEES- Plan Sets Pian Cheng submitted Item Amount Structural Cales. Revlewed, ready for corrections Plan Check Deposit. . Tram Calcs. Called Contact Person Plan Check Balance Title 24 Cates. Plans picked up Construction Flood plain plan Pians resubmitted- , Mechanical Giading plan Review, ready for corrections/issue Electrical Subeoutaetor List Called ContactPerson Plumbing Grant Deed Pians picked up S bLL H.O.A. Approval Plans resubmitted Grading IN QOUSE:- 1j° Review; ready for eorrectlons/casae Developer Impact Fee Planning Approval. Called Contact Person A.I.P.P. Pub. Wks. Appr ' Date of permit issue School Fees Total Permit Fees SEP 1 8 2015 CITY OF LA QUINTA COMMUNITY DEVFLOPMEIVT YOUNG 's -_ ENGINEERING a� o o e o n• `. Lettei,of Transmittal. , Y To: City of La Quints Today's Date: 78-495 Calle Tampico. City Due Date: 1-7-16 La Quinta, CA 92253. Project Address: 81-255 National Drive Attn: Kay /Jim Plan Check #. . BRES2015 0375: 7 Submittal ❑ si`r, ❑ "4tn t :c r ® 2nd i 0 » 5th ` ,• :. ❑ 3rd ' , Other: * We are forwarding: ® By Messenger ❑ By Mail (Fed Ex or UPS) •' -t,,: . ❑. Your Pickup Includes: Descriptions: Includes: # 0f Descriptions: Copies:- ❑ Structural Plans ® 2 Revised Struct. Plans' ❑ Structural Calculations ®; 1 . Revise'd.Struct. Calcs ❑ Truss Calcs El:== Revised Truss Calcs Soils Report 4.. • ` ❑ :' :y ' Revised Soils Report ® 1 Structural P/C Comments ❑ r«f , ' ;Approved Structural Plans.' .° /Responses A ® 1 Redlined Structural Plans ❑ -Approved Structural Calcs ® 1 Redlined Structural Calcs '❑ ; Approved Truss Calcs . ❑ Redlined Truss Calcs ❑ > Approved Soils Report ❑ Redlined Soils Reports '' 'Other: .., REREIVE Comments: Structural content is approvable. , LJ J.A.nl 0 a 9;e` CITY: OF LA Qt alhIZA Structural Plan Review'Time.= 1.25 HR rnMMl1NIN DEVPr^� This M�ater1aI-Sent for":' or Your Files ®. Per Your:,Request Your Review. ❑ Approval • ❑-Checking ' _ ❑. �. * At the request of Other:❑' By: John W. Thompson Office: ® (760) 772-5107 Other : ❑ � :. - BUILDING ENERGYANALYSISREPORT PROJECT: SINGLE HOUSE ADDITION 81255 NATIONAL DR. LA QUINTA, CA 92253 Project Designer: KEN'S DESIGNS RECEIVEU 714-931-0295 SEP 18 2015 CITY Or LA QUINTA COMMUNITY DEVELOPMENT Report Prepared by: PERFECT DESIGN & DEVELOPMENT, INC. o z00 Vic` m No 7gM 7 r Job Number: R15-4311lNonresidentia &Eenc Date: R 9/11/2015N R The EnergyPro computer program has been used to perform the calculations summarirtepyal and is authorized by the California Energy Commission for use with both the Residential anndards. This program developed by EnergySoft, LLC—www.energysoft.com. -EnergyPro 6.7 by EnergySoft User Number 1919 /D: R15-4311 TABLE OF CONTENTS Cover Page Table of Contents 2 Form CF -1 R -PRF -01-E Certificate of Compliance 3 Form RMS -1 Residential Measures Summary 11 Form MF -1 R Mandatory Measures Summary 12 HVAC System Heating and Cooling Loads Summary 16' Room Load Summary 17 Room Heating Peak Loads - 18 Room Cooling Peak Loads '21 S { r EnergyPro 6.7 by EnergySoft Job Number: ID: R15-4311 User Number: 1919 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: SINGLE HOUSE ADDITION Calculation Date/Time: 15:26, Fri, Sep 11, 2015 Calculation Description: Title 24 Analysis Input File Name: R15-4311.xml CF1R-PRF-n1 Page 1 of 8 GENERAL INFORMATION 01 Building Complies with Computer; Pekorma'a' 01 Project Name SINGLE HOUSE ADDITION 04 02 02 Calculation Description Title 24 Analysis 08 } 03 Project Location 81255 NATIONAL DR. Compliance Margin Percent Improvement 04 City LA QUINTA 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 180 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) .4036 15 Number of Zones 3 16 Slab Area (ft) 3764 17 Number of Stories 2 18 Addition Cond. Floor Area 56 19 Natural Gas Available Yes 20 Addition Slab Area..(ft2) 56 21 Glazing Percentage (%) 17.7% COMPLIANCE RESULTS 01 Building Complies with Computer; Pekorma'a' 04 02 This building DOES NOT require HERS Veification,. ( 08 } Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 13.59 13.86 -0.27 Registration'Number: 215-A6323346A-000000000-0000 Registration Date/Time: 2015-09-11 15:28:51 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-09-1115:27:16 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ftZ-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 13.59 13.86 -0.27 -2.0% Space Cooling 387.33 385.65 1.68 0.4% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 7.47 7.47 0.00 0.0% Photovoltaic Offset ---- 0.00 0.00 ---- Compliance Energy Total 408.39 406.98 1.41 0.3% Registration'Number: 215-A6323346A-000000000-0000 Registration Date/Time: 2015-09-11 15:28:51 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-09-1115:27:16 ' CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-(!1 Project Name: SINGLE HOUSE ADDITION Calculation Date/Time: 15:26, Fri, Sep 11, 2015 Page 2 of 8 Calculation Description: Title 24 Analysis Input File Name: R15-4311.xml REQUIRED SPECIAL FEATURES rhe following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. SIO SPECIAL FEATURES REQUIRED HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: --None -- Cooling System Verifications: None -- HVAC Distribution System Verifications: --None -- Domestic Hot Water System Verifications: --None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an = on-site renewable energy system. t' 04 05 Reference Energy Use; Energy:Design;Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)* 446.95 ' -' 445.54 - — . 1.41 0.3% ,.A N..` C-' 1," ' Ifs `e...r° V i LJ r: r``a * includes calculated Appliances and Miscellaneous Energy Use (AMEU)` BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation " Cooling Systems Number of Water Heating Systems SINGLE HOUSE ADDITION 4036 1 4 3 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 ADDITION 1ST FLOOR Conditioned WHOLE HOUSE1 56 10 DHW Sys 1 EXISTING 1ST FLOOR Conditioned WHOLE HOUSE1 3708 10 DHW Sys 1 EXISTING 2ND FLOOR Conditioned WHOLE HOUSE1 272 9 1 DHW Sys 1 Registration Number: 215-A6323346A-000000000-0000. Registration Date/Time: 2015-09-11 15:28:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-09-1115:27:16 CERTirFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF'IR-PRF-04 Project Name: SINGLE HOUSE ADDITION Calculation Date/Time: 15:26, Fri, Sep 11, 2015 Page 3 of 8 Calculation Description: Title 24 Analysis Input File Name: R15-4311.xm1 OPAQUE SURFACES .. d + 02. 03 04 05 06 07 08 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ft) Tilt (deg) Status Verified Existing Condition EAST WALL ADDITION 1ST FLOOR R-15 Wall 90 Right 40 0.1 90 New N/A NORTH WALL ADDITION 1ST FLOOR R-15 Wall 0 Back 140 96 90 New N/A ROOF ADDITION 1ST FLOOR R-30 Roof Attic Attic RoofEXISTING 1ST Ventilated 56 0.1 0.85 New N/A WEST WALL EXISTING 1ST FLOOR Default Wall Prior 1950 270' Left 1170 136 90 Existing No EAST WALL 2 EXISTING 1ST FLOOR Default Wall Prior 1950 90 Right 1130 199 90 Existing No NORTH WALL 2 EXISTING 1ST FLOOR Default Wall Prior 1950 0 Back 450 168 90 Existing No SOUTH WALL EXISTING 1ST FLOOR Default Wall Prior 1950 180 Front 590 66 90 Existing No EXISTING ROOF EXISTING 1ST:FLOOR Default Roof 1950 to Pres 3436 Existing No WEST WALL 2 EXISTING 2ND FLOOR Default Wall Prior 1950 270 Left 180 90 Existing No EAST WALL 3 EXISTING 2ND FLOOR_ Default Wall Prior 1950 90 Right 180 90 Existing No NORTH WALL 3 EXISTING 2ND FLOOR Default Wall Prior 1950 0 Back. 105.6 48.2 90 Existing No SOUTH WALL 2 EXISTING 2ND FLOORDefault;Wall Pno°1950 1'j t180� Front �105i6 90 Existing No EXISTING ROOF 2 EXISTING 2ND FLOOR �i �pefaultlRoof 1950'.to Pres`, I 27>2Iti Existing No ATTIC..t P i_� 1E R01 .. d + 02. 03 04 05 06 07 08 09 10 Radiant Statu Verified Existing Name Construction Type Roof Rise Roof Reflectance Roof Emittance Barrier Cool Roof s Condition Attic ADDITION 1 ST FLOOR Attic RoofADDITION 1ST Ventilated 4 0.1 0.85 No No New No FLOOR Attic EXISTING 1ST FLOOR Attic RoofEXISTING 1ST Ventilated 4 0.1 0.85 No No Existi No FLOOR ng Attic EXISTING 2ND FLOOR Attic RoofEXISTING 2ND Ventilated 4 0.1 0.85 No No Existi No FLOOR ng Registration Number: 215-A6323346A-000000000-0000 Registration Date/Time: 2015-09-11 15:28:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-09-1115:27:16 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: SINGLE HOUSE ADDITION Calculation Date/Time: 15:26, Fri, Sep 11, 2015 Page 4 of 8 Calculation Description: Title 24 Analysis Input File Name: R15-4311.xml WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplie r Area (ft) U -factor SHGC Exterior Shading Status Verified Existing Condition WINDOWS NORTH WALL (Back -0) ---- ---- 1 96.0 0.30 0.21 Insect Screen (default) New N/A WINDOWS 2 WEST WALL (Left -270) 1 136.0 1.19 0.83 Insect Screen (default) Existing No WINDOWS 3 EAST WALL 2 (Right -90) ---- ---- 1 199.0 1.19 0.83 Insect.Screeh (default) Existing No WINDOWS 4 NORTH WALL 2 (Back -0) ---- ---- 1 168.0 1.19 0.83 Insect Screen (default) Existing No WINDOWS 5 SOUTH WALL (Front -180) ---- ---- 1 66.0 1.19 0.83 • Insect Screen (default) Existing No WINDOWS 6 NORTH WALL 3 (Back -0) 1 48.2 1.19 0.83 Insect Screen (default) Existing No t Registration Number: 215-A6323346A-000000000-0000 Registration Date/Time: 2015-09-11 15:28:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-09-11 15:27:16 .^�.Af �i^k.�l ?' I" YY.n«.F„...�d t Registration Number: 215-A6323346A-000000000-0000 Registration Date/Time: 2015-09-11 15:28:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-09-11 15:27:16 CERTAFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: SINGLE HOUSE ADDITION Calculation Date/Time: 15:26, Fri, Sep 11, 2015 Calculation Description: Title 24 Analysis Input File Name: R15-4311.xm1 CFI R-PRF-QI Page 5 of 8 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Construction Name Surface Type Construction Type Framing Total Cavity R -value Winter Design U -value Assembly Layers Carpeted Fraction Heated. Status Verified Existing Condition Covered Slab. ADDITION 1ST FLOOR • Cavity/Frame: no insul. /2x4 Top Chrd Attic RoofADDITION 1 ST None 0.8 2x4 Top Chord of Roof Truss @ 24 New No • Roof Deck: Wood Siding/sheathing/decking Tile Gap: present FLOOR Attic Roofs Wood Framed Ceiling in. O.C. none 0.400 Roofing: 10 PSF (Roofl-ile) No Ceilings (below • Inside Finish: Gypsum Board R-30 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 30 0.032 Cavity/ Frame: R-9.1 /2x4 Over Floor Joists: R-20.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R -15/2x4 R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 15 0.089 • Exterior Finish: Wood Siding/sheathing/decking • Cavity/ Frame: no insul. / 2x4 Top Chrd Attic RoofEXISTING 1ST 2x4 Top Chord of Roof Truss @ 24 • Roof Deck: Wood Siding/sheathing/decking Tile Gap: present FLOOR Attic Roofs Wood Framed Ceiling in. O.C. none 0.400 Roofing: 10 PSF (RoofTile) Default Roof 1950 to Pres Ceilin s: below � .--* `' �-°[ Inside Finish: Gypsum Board attic Wood Framed d Ceiling; 2x4 @ 16 i O.C. # none 17.472 Cavity/ Frame: no insul. / 2x4 Inside Finish: Gypsum Board �Wood Cavity/Frame: no insul. / 2x4 Default Wall Prior 1950 Exterior Walls Wall 2z4 O C. t � Exterior Finish: Wood Frame @ 16��in. ~' F on - � 0.302 Siding/sheathing/decking • Cavity/ Frame: no insul. /2x4 Top Chrd • Roof Deck: Wood Siding/sheathing/decking Attic RoofEXISTING 2ND 2x4 Top Chord of Roof Truss @ 24 Tile Gap: present FLOOR Attic Roofs Wood Framed Ceiling in. O.C. none 0.400 Roofing: 10 PSF (RoofTile) • Floor Surface: Carpeted • Floor Deck: Wood Siding/sheathing/decking • Cavity/Frame: no insul. /2x12 Default Floor No Crwlspce Interior Floors Wood Framed Floor 2x12 @ 16 in. O.C. none 0.196 Ceiling Below Finish: Gypsum Board SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated. Status Verified Existing Condition Covered Slab. ADDITION 1ST FLOOR 56 18 None 0.8 No New No Covered Slab 2 EXISTING 1ST FLOOR 3708 334 None 0.8 No Existing No Registration Number: 215-A6323346A-000000000-0000 Registration Date/Time: 2015-09-11 15:28:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-09-1115:27:16 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: SINGLE HOUSE ADDITION Calculation Date/Time: 15:26, Fri, Sep 11, 2015 Calculation Description: Title 24 Analysis Input File Name: R15-4311.xml BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required --- CFI R -PRF -01 Page 6 of 8 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name _ System Type Distribution Type Water Heater Number of Heaters° Solar Fraction ( /°) Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 1 Annual Existing No WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater ElemenfType Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Stora a.,, , 4 x50 0.53 EF 37000-Btu/hr 0 0.04 WATER HEATING - HERS VERIFICATION `k 01 02~ 03' '_ _._ '04 !�' _ X05 06 07 09 Heating System Cooling System Recirculation with Recirculation with Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Manual Control Sensor Control DHW Sys 1 . n/a n/a n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Heating System Cooling System Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition WHOLE HOUSEI Other Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 4036 Existing No Cooling System Component 1 Component 1 System 1 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Registration Number: 215-A6323346A-000000000-0000 Registration Date/Time: 2015-09-11 15:28:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-09-1115:27:16 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Project Name: SINGLE HOUSE ADDITION Calculation Date/Time: 15:26, Fri, Sep 11, 2015 Page 7 of 8 Calculation Description: Title 24 Analysis Input File Name: R15-4311.xml HVAC -COOLING SYSTEMS 01 02 03 04 05 06 07 07 08 Efficiency 10 D� , � kag ' Target (/a) ,� ° Verified Duct Location Name System Type EER SEER Zonally Controlled Multi -speed Compressor HERS Verification CoolingCom Component 1 SplitAirCond - Split air conditioning 9.2 10 No R -value Location Location system Status Condition Verification No N/A HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 D� , � kag ' Target (/a) ,� ° Verified Duct Location Verified Duct Design Return Supply Insulation Supply Duct Return Duct $ i;�` is Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution System 1 Ducts located in attic Existing (not specified) 4.2 Attic Attic None ExistingNo N/A HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leak1. wage Verification D� , � kag ' Target (/a) ,� ° Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1 -hers -dist `N%A�:-"`.�*h ` ='i $ i;�` is IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 0 Not Required Registration Number: 215-A6323346A-000000000-0000 Registration Date/Time: 2015-09-11 15:28:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-09-1115:27:16 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: SINGLE HOUSE ADDITION Calculation Date/Time: 15:26, Fri, Sep 11, 2015 Calculation Description: Title 24 Analysis Input File Name: R15-4311.xm1 CF1 R -PRF -01 Page 8 of 8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Raymond Zhong Company: Signature Date: 7 N Perfect Design t< F c 2015-09-11 15:28:51 r TA Address: CEA/HERS Certification Identification 2416 W. Valley Blvd. City/State/Zip: Phone: Alhambra, CA 91803 6262898808'��1F02 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of. Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to -the enforcement agency -for approval with this,building permit application. Responsible Designer Name: �`� ,'r ' .,ate Responsible Designer Signature:,x'"` ,f.;r... f +. � '. a..'&"T+:. `t>.,.s;'� a� I �w.-.!"� �...+� { 1. 1 f { :�: fir. "�"`°r.,3" �� =F is '•wup t�i Company: x ne Date, Signed: Address: License: City/State/Zip: Phone: Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-A6323346A-000000000-0000 Registration Date/Time: 2015-09-11 15:29:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-09-1115:27:16 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name SINGLE HOUSE ADDITION Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 9/11/2015 Project Address 81255 NATIONAL DR. LA QUINTA California Energy Climate Zonotal CA Climate Zone 15e Cond. Floor Area T 4,036 Addition 56 # of Units 1 INSULATION Construction Type Area Cavity (0 Special Features Status Roof Wood Framed Attic R30 56 New Wall Wood Framed R 15 444 New Slab Unheated Slab -on -Grade no insulation 56 Perim = 18' New Roof Wood Framed Attic no insulation 3,708 Existing Wall . Wood Framed no insulation 3,294 Existing Slab Unheated Slab -on -Grade no insulation 3,708 Perim = 334' Existing Demising Wood Framed w/o Crawl Space no insulation 272 Existing FENESTRATION I Total Area: 713 Glazing Percentage: 17.7%1 Orientation Area(ft) U -Fac SHGC Overhang Sidefins New/Altered Average U -Factor: 0.30 Exterior Shades Status Left (W) 0.0 0.300 0.21 none none Bug Screen New Right (E) 0.0 0.300 0.21 none none Bug Screen New Rear (N) 96.0 0.300 0.21 none none Bug Screen New Front (S) 0.0 0.300 0.21 none none Bug Screen New Left (W) 136.0 1.190 0.83 none none Bug Screen Existing Right (E) 199.0 1.190 0.83 none none Bug Screen Existing Rear (N) 216.2 1.190 0.83 none none Bug Screen Existing Front (S) 66.0 1.190 0.83 none none Bug Screen Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 80% AFUE Split Air Conditioner 10.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R -Value Status WHOLE HOUSE Ducted Ducted Attic 4.2 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener Pro 6.7 by Ene Soft User Number: 1919 RunCode: 2015-09-11 T15:27:33 ID: R15-4311 Pae 11 of 23 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the comvlionce aooroach used Exceptions mai; annly. Review the resnertive rnde wrlinn fnr mnre infnrmntinn_ Building Envelope Measures: §1 10.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §1 10.6(x)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration that meets the requirements of §10-1 1 1(a). § 1 10.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. §1 10.8(x): Insulation specified or installed meets Standards for Insulating Material. indicate type and include on the CF2R. §1 10.8(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the installation of a cool roof is specified on the CF I R. §1 10.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a § 150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. § 150.0(6): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. § I50.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). § 150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. § 150.0(g)1: In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior walls, vented attics and unvented attics with air -permeable insulation. § i 50.0(8)2: In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class 1 or Class II vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class 11 vapor retarder shall be placed over the earth floor of § 150.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). § 150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8( ). § 150.0(q): Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U - factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § 150.0(e) I A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. § 150.0(e) I C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. § I50.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: § 1 10.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. 1 10.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve; and recirculation loop connection requirements of § 1 10.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- § 1 10.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. §i50.0(h)1: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in §I50.0(h)2. § 150.0(h)3A: installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. §I50.0(i): Heating systems are equipped with thermostats that meet the setback requirements of §1 10.2(c). §I50.0(j)IA: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance ofR-12 or greater. § 150.0(j)1 B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R- 16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system §150.00)2A: regardless of the pipe diameter; piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. § 150.00)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation; removal, and replacement of the enclosed pipe and insulation. 2013 Low -Rise Residential Mandatory Measures Summary § I50.0Q)2C: Pipe for cooling system lines shall be insulated as specified in § 150.0(j)2A. Piping insulation for steam and hydropic heating systems or hot water systems with pressure > 15 psig shall meet the requirements in TABLE _I20.3 -A. § 150.0(j)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance; and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For § I50.0Q)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class i §150.0(j)3B: or Class 11 vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class fl vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category iii or IV vent, or a Type B vent with straight pipe between the outside termination and the § 150.0(n)1: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 1 10.3(c)5. Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) § 150.0(n)3: or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed § I50.0(m)I with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § 150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. § 150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(x)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not § 150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be §i 50.0(m)I l: sealed and duct leakage tested, as confirmned through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § I50.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of § 150.0(m)12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (iJSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. Tile § I50.0(m)13: space conditioning system must also demonstrate airflow _> 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy S 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, §I50.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of § 150.0(0): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. §I50.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat selling; a permanent weatherproof plate or card with operating instructions: and shall not use electric resistance heating. 2013 Low -Mise Residential Mandatory Measures Summary § 110.4(b)i : Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines. or built-up connections for fixture solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 110 4(b)3: Pools shall have directional inlets that adequately mix the pool water; and a time switch that will allow all pumps to be set or pro- oranuned to run only during off-peak electric demand periods. §1 10.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. § 150.0(p): Residential pool systems or equipment shall meet specified pump sizing; flow rate, piping, filters, and valve requirements. Lighting Measures: § 1109: All lighting control devices and systems; ballasts, and luminaires shall meet the applicable requirements of §110.9. 150.0(k)1 A: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-13. as applicable. § 150.0(k) I B: when a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § I50.0(k)I C: § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. § 150.0(k) I D: Ballasts for Fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kI-Iz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no § 150.0(k) I E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §I30.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k) I F: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of § 150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. § I50.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § I50.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § I50.0(k)2D: Controls and equipment are installed in accordance with manufacturers instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k). § I50.0(k)2F: Lighting controls comply with applicable requirements of §110.9. An Energy Management Control System (FMCS) may be used to comply with dimmer requirements if.. it functions as a dimmer § I50.0(k)2G: according to § 110.9; meets installation Certificate requirements of §130.4; the EMCS requirements of § 130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of §I50.0(k) if: it § 150.0(k)2H: functions as a vacancy sensor according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of§130.5,- and all other requirements in §I50.0(k)2. § 150.0(k)21: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in §150.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. § 150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illum inated cabinet. § 150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. § 150.0(k)6:. Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. § I50.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CPM at 75 Pascals when tested in accordance with ASTM E283: be sealed with a gasket or caulk between the luminaire housing § 150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact Fluorescent luminaries with ballasts to qualify as high efficacy for compliance with §I50.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in §110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items ii or iii below; and § 150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours: and iii. Controlled by one of the following methods: 2013 Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an override or bydass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets a!I of the following requirements: At a mininuun provides the functionality of an astronomical time clock in accordance with § 110.9,- meets the Installation Certification requirements in § 130.4; meets the requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is prograrnmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the §I50.0(k)9B: following requirements: i. Shall comply with §1 50.0(k)9A,- or ii. Shall comply with the applicable requirements in §110.9, §130.0, §1.30.2, $130.4, §140.7 and §141.0. §I50.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by. § I 50.0(k)9 B or 150.0(k)9D shall comply with the applicable requirements in §110.9, § 130.0, §130.2, §130.4, §140.7 and §141.0. § I50.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in § 1 10.9, §'130.0, § 130.2. $130.4, § 140.7 and § 141.0. §I50.0(k)10: Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined according to §130.0(c). § I50.0(k)1 1: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in § 110.9, § 130.0, § 130. 1, § 130.4, § 140.6, and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § 150.0(k) I2A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, pennanently installed lighting in that building shall: §I50.0(k)12B: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 110.10(a)1: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of §I 10.10(b) through §1 10.10(e). §I 10.10(a)2: Low-rise multi -family buildings shall comply with the requirements of §110.10(b) through §110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for § 110.10(b) I : buildings with roof areas greater than 10,000 square feet. For single family, residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 1 10.10(b)2: All sections of the solar zone located on steep' sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. 10.10(b)3A: No obstructions; including but not limited to, vents; chimneys, architectural features, and roof mounted equipment; shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height dilTerence between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 1 10.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 1 10.10(d): A copy of the construction documents or a comparable document indicating the information from § 1 10.10(b) through § 1 10.10(c) shall be provided to the occupant. § 110.10(e)1: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location. and permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name SINGLE HOUSE ADDITION Date 9/11/2015 System Name WHOLE HOUSE Floor Area 4,036 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFMSensible Total Room Loads 11,248 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output per System 89,000 163,367 3,973 3,651 146,910 Total Output (Btuh) 178,000 0 Output Btuh/s ft 44.1 13,853 10,438 Cooling System 0 0 Output per System 57,000 0 0 0 0 Total Output Btuh 114,000 0 3;973 0 Total Output Tons 9.5 13,853 10,438 Total Output (Btuh/sgft) 28.2 Total Output s ft/Ton 424.8 191,072 167,785 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 4,000 EXISTING A/C UNIT 75,122 30,254 178,000 Airflow cfm/sgft 0.99 Airflow (cfm/Ton) 421.1 Outside Air % 0.0 % Total Adjusted System Output 75,122 30,254 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM 178,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF Outside Air 0 cfm 66 IF 66 OF 108 OF 108 °F �- >... IC �- DID-��--- Heating Coil Supply Fan 106 OF 4,000 cfm BOOM, , 68 IF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112 178 OF Outside Air Ar 0 cfm 8G/67°F 80 167 OF 62161 OF 62161 IF a Cooling Coil Supply Fan 64 / 62 OF 4,000 cfm ;—"�(—"—/"�— 56.1 % j ROOM 78167 IF -0- =1W EnergyPro 6.7 by EnergySoft User Number: 1919 RunCode: 2015-09-11 T15:27:33 /D: R15-4311 Page 16 of 23 ROOM LOAD SUMMARY rrolect Name Date SINGLE HOUSE ADDITION 9/11/2015 System Name Floor Area WHOLE HOUSE 4,036 ROOM LOAD SUMMARY PAGE TOTAL TOTAL* 11,248 163,367 3,973 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible ADDITION IST FLOOR ADDITION 1ST FLOOR 1 128 1,859 55 128 1,859 55 57 2,276 EXISTING 1STFLOOR EXISTING 1STFLOOR 1 10,168 147,675 3,650 10,168 147,675 3,650 3,242 130,460 EXISTING 2ND FLOOR EXISTING 2ND FLOOR 1 952 13,833 268 952 13,833 268 352 14,174 PAGE TOTAL TOTAL* 11,248 163,367 3,973 3,651 146,910 11,248 163,367 3,973 3,651 146,910 * Total includes ventilation load for zonal systems. Ener Pro 6.7 by EnergySoft User Number. 1919 RunCode: 2015-09-11 T15:27:33 ID: R15-4311 Pae 17 of 23 ROOM HEATING PEAK LOADS Project Name SINGLE HOUSE ADDITION Date 9/11/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name ADDITION IST FLOOR Floor Area 56.0 ft2 Indoor Dry Bulb Temperature 68 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X - X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F = _ 0 = = = = = = = = = = = = = = = = = = = = = = = = 42 Btu/hr R-30 Roof Attic 56.0 0.0310 42 73 R-15 Wall 84.0 0.0950 42 335 Double Non Metal Clear (6) 96.0 0.3000 42 1,210 'R-15 Wall 180.0 0.0950 0 0 Slab -On -Grade perim = 18.0 0.7300 42 552 Items shown with an asterisk (*) denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 56 X Area another room 10.00 X 0.255 Height ACH Page Total /60] X AT 2,170 = 107 TOTAL HOURLY HEAT LOSS FOR ROOM 2,276 EnergyPro 6.7 by EnergySoft User Number: 1919 RunCode: 2015-09-11 T15:27:33 /D: R15-4311 Page 18 of 23 ROOM HEATING PEAK LOADS Project Name SINGLE HOUSE ADDITION Date 9/11/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name EXISTING 1ST FLOOR Floor Area 3, 708.0 ft' Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area 3,436.0 X U -Value X X X X X X X X X X X X X X X X X X X X X' X X X X X X X X X X AT °F = = = c = = = = = = = = = - = = = = = = _ = = = = = = = = = = 42 Btu/hr Default Roof 1950 to Present. 0.3000 42 43,294 Default Wall Prior 1950 to Present 2,771.0 X 0.3560 42 41,432 Default Single Metal Clear 569.0 X 1.1900 42 28,439 'R-15 Wall 180.0 X 0.0950 0 0 Slab -On -Grade perim = 334.0 X X 0.7300 42 10,240 X X X X X X X X X X X X X X X X X. X X X X X X X X Items shown with an asterisk (") denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface to X 3, 708 X Area Ceiling another room 10.00 X 0.255 Height ACH Page Total /60] X AT 123,405 = 7,055 TOTAL HOURLY HEAT LOSS FOR ROOM 130,460 EnergyPro 6.7 by EnergySoft User Number.- 1919 RunCode: 2015-09-11 T15:27:33 /D: R15-4311 Page 19 of 23 ROOM HEATING PEAK LOADS Project Name SINGLE HOUSE ADDITION Date 9/11/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name EXISTING 2ND FLOOR Floor Area 272.0 ft2 Indoor Dr Bulb Temperature 68 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X . X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F c c = = = = = = = = = = = = = = = = = = = = = = = = = = = 42 Btu/hr Default Roof 1950 to Present. 272.0 0.3000 42 3,427 Default Wall Prior 1950 to Present 523.0 0.3560 42 7,820 Default Single Metal Clear 48.2 1.1900 42 2,409 "Default Floor No Crwlspce 1950 to Present 272.0 0.2380 0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 272 X Area another room 9.00 X 0.284 Height ACH Page Total /60] X AT 13,656 = 518 TOTAL HOURLY HEAT LOSS FOR ROOM 14,174 EnergyPro 6.7 by EnergySoft User Number: 1919 RunCode: 2015-09-11 T15:27:33 /D: R15-4311 Page 20 of 23 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date SINGLE HOUSE ADDITION 9/11/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name ADDITION IST FLOOR Outdoor Dry Bulb Temperature 112 OF Floor Area 56.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-30 Roof Attic (N) 56.0 X 0.0310 X 56.0 = 97 R-15 Wall (E) 40.0 X 0.0950 X 33.0 = 125 R-15 Wall (N) 44.0 X 0.0950 X 23.0 = 96 "R-15 Wall 180.0 X 0.0950 X 0.0 = 0 X X = X X = X X = X X = X X = Page Total 319 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr WINDOWS (W) 0.0 X 13.8 + 0.0 X 26.3 = 0 WINDOWS (E) 0.0 X 13.8 + 0.0 X 26.3 = 0 WINDOWS (N) 0.0 X 13.8 + 96.0 X 13.8 = 1,324 WINDOWS (S) 0.0 X 13.8 + 0.0 X 13.8 = 0 X + X = X + X = X + X = X + X = X + X = Page Total 1,324 Internal Gain Btu/hr Occupants 0.2 Occupants X 245 Btuh/occ. = 41 Equipment 56 Floor Area X 0.50 w/sgft = 96 Infiltration: 1.064 X 0.87 X 2.55 X 34 = 80 Air Sensible CFM ELA 4T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 1,859 Latent Gain Btu/hr Occupants 0.2 Occupants X 155 Btuh/occ. = 26 Infiltration: 4,771 X 0.87 X 2.55 X 0.00276 = 29 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 26 Ener Pro 6.7 by EneMySoft User Number. 1919 RunCode: 2015-09-11 T15:27:33 ID: R15-4311 Page 21 of 23 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date SINGLE HOUSE ADDITION 9/11/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name EXISTING 1ST FLOOR Outdoor Dry Bulb Temperature 112 OF Floor Area 3,708. 0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr Default Roof 1950 to Present. (N) 3,436.01 X 0.3000 X 56.0 = 57,725 Default Wall Prior 1950 to Present 1,034.0 X 0.3560 X 33.0 = 12,147 Default Wall Prior 1950 to Present (E) 931.0 X 0.3560 X 33.0 = 10,937 Default Wall Prior 1950 to Present (N) 282.0 X 0.3560 X 23.0 = 2,309 Default Wall Prior 1950 to Present (S) 524.0 X 0.3560 X 26.0 = 4,850 'R-15 Wall 180.0 X 0.0950 X 0.0 = 0 X X = X X = X X = Page Total 87,969 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btulhr WINDOWS (K9 0.0 X ,52.6 + 136.0 X 98.6 = 13,416 WINDOWS (E) 0.0 X 52.6 + 199.0 X 98.6 = 19,631 WINDOWS (N) 0.0 X 52.6 + 168.0 X 52.6 = 8,835 WINDOWS (S) 0.0 X 52.6 + 66.0 X 52.8 = 3,483 X + X = X + X _ X + X = X + X = X + X = Page Total 45,364 Internal Gain Btu/hr Occupants 11.1 Occupants X 245 Btuh/occ. = 2,725 Equipment 3,708 Floor Area X 0.50 w/sgft = 6,328 Infiltration: 1.064 X 0.87 X 168.79 X 34 = 5,288 Air Sensible CFM ELA AT . TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 147,675 Latent Gain Btu/hr Occupants 11.1 Occupants X 155 Btuh/occ. = 1,724 Infiltration: 4,771 X 0.87 X 168.79 X 0.00276 - 1,926 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,724 Ener Pro 6.7 by EnergySoft User Number: 1919 RunCode: 2015-09-11 T15:27:33 ID: R15-4311 Page 22 of 91 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date SINGLE HOUSE ADDITION 9/11/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name EXISTING 2ND FLOOR Outdoor Dry Bulb Temperature 112 OF Floor Area 272.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Dailv Rancie: 34 OF Orientation Default Roof 1950 to Present. Default Wall Prior 1950 to Present Default Wall Prior 1950 to Present Default Wall Prior 1950 to Present Default Wall Prior 1950 to Present 'Default Floor No Crw/spce 1950 to (N) (W) (E) (N) (S) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = _ = 272.0 0.3000 56.0 180.0 0.3560 33.0 180.0 0.3560 33.0 57.4 0.3560 23.0 105.6 0.3560 26.0 272.0 0.2380 0.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration WINDOWS WINDOWS WINDOWS WINDOWS Internal Gain Orientation (IM (E) (N) (S) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 52.6 0.0 98.6 0.0 52.6 0.0 98.6 0.0 52.6 48.2 52.6 0.0 52.6 0.0 52.8 Page Total 0.8 Occupants X 245 Btuh/occ. 272 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 0.87 X 12.38 X 34 = Air Sensible CFM ELA AT Btu/hr 2,115 2,115 1 Btu/hr 0 0 2,535 0 2,+ Btu/hr 1 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13.8331 Latent Gain Btu/hr Occupants 0.8 Occupants X 155 Btuh/occ. = 126 Infiltration: 4.771 X 0.87 X 12.38 X 0.00276 = 141 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 126 IEnergyPro 6.7 by EnergySoft User Number.- 1919 RunCode: 2015-09-11 T15:27:33 ID: R15-4311 Page 23 of 231