Loading...
RPL (07-0196)0 P.O. BOX 1504 . - 78-495 CALLE TAMPICO LA,QUINTA, CALIFORNIA 92253 Application Number: 07-00000196 Property Address: 81420 NATIONAL DR APN: 767-57.0-008- - - • Application description:. POOL - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 23000 Applicant: Architect or Engineer: BUILDING & SAFETY DEPARTMENT . BUILDING PERMIT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: C53 License No.: 61461.1 Date: Contractor: - - ^ OWNER -BUILDER DECLARATION ` I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuanttothe provisions of the Contractor's State License.Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption' Any violation of Section 7031.5 by ` any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, . and who does the work himself or herself through his or her own employees, provided that the ' improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( X) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.' 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). - I am exempt under Sec. , BAP.C. for this reason "/ G -a7Owner-. • CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the J work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: J LQPERMIT Owner: , LABONIA 81420 NATIONAL DRIVE' LA QUINTA, CA 92253 Contractor. MCINTYRE POOLS 83695.AVENUE 4 INDIO, CA 9220 (760)342-3612 Lic. No.: 6146 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 7/06/07 . • WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: - I have and will maintain a certificate of consent to self -insure for workers' compensation, 'as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier MAJESTIC INS CO Policy Number 020060333602 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section / �)377000of the Labor Code/, I/I hall fo'rtthwoithhccomply with those provisions. ate: TJ T/ v Applicant: ��,�eJIGE'C1 WARNING: FAILURE T0, SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . -Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180'days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and, state laws relating to building construction, and hereby authorize representative's of �county enter uon the above-mentioned property f inspecti pu poses '�C 'f9 ate: ignature (Applicant or Agent)' L - Application Number . .. 07-00000196 • Permit BLDG POOL -PERMIT Additional desc . Permit Fee . . . . 234.00 Plan Check Fee 152.10 Issue Date 1/22/07 Valuation . . . . 23000 Expiration Date 7/21/07, Qty , Unit Charge Per Extension BASE FEE 45".00 21.00 9.0000 THOU BLDG 2,001-25,000 189.00 Permit MECH POOL Additional desc . Permit Fee . . . . 26.00 Plan Check Fee 6.50 Issue Date 1/22/07 Valuation . . . . 0 Expiration Date 7/21/07 Qty Unit Charge Per Extension BASE FEE' 15.00 1.00 11.0000.EA MECH FURNACE >100K 11.00 Permit ELEC POOL PERMIT -RES Additional desc ... Permit Fee . . . . 45.00 Plan Check Fee 11.25 Issue Date " : . . . 1/22/07 Valuation 0 Expiration Date 7/21/07 Qty Unit Charge Per Extension BASE FEE '15.00 1.00 30.0000 EA ELEC PRIVATE SWIMMING POOL 30.00 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 33.00 Plan Check Fee 8.25 - Issue Date . . . . 1/22/07: Valuation 0 Expiration Date 7/21/07 Qty Unit Charge. Per Extension BASE FEE 15.00 2.00 6.0000 EA PLB FIXTURE 12.00 1.00 3.0000 EA PLB, WATER INST/ALT/REP 3.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 ---------------------------------------------------------------------------- Special Notes and Comments POOL/SPA. ALARMS/BARRIERS SHALL BE IN LQPERMIT - . LQPERMIT . Application.Number 07-00000196 ------------------------------------------- Special Notes and Comments PLACE AT PRE -PLASTER INSPECTION. EQUIPMENT ENCLOSURE NOT INCLUDED - - - - -- - -----------------------.-------------- Other Fees CHANGE OF CONTRACTOR --------------- 4.50,. Fee summary. Charged Paid Credited Due - - - ----- Permit Fee Total 338.00 - - - - - -- 338.00 ---- - - - - - - ---------- .00 .00 Plan Check Total 178.10 178.10 .00 .00 Other.Fee Total 4.50 .00 .00 4.50' Grand Total 520.60 516.10 .00 4.50 LQPERMIT P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: �7-00000196 Property Address: 81420 NATIONAL DR\ APN:' 767-570-008- - Application description: POOL - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 23000 Applicant: Architect or Engineer: P/rt BUILDING & SAFETY DEPARTMENT BUILDING PERMIT ' LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: A B C8 C29 _ License No.: 751092 ate: ntractor: 7 OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit'subjects the applicant to a civil penalty of not more than five hundred dollars (5500).: (_ I I, as owner of the property, or my employees with wages as their sole compensation, will do -the work, and the structure is not intended or offered for. sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agencyfor the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPE"I IT Owner: LABONIA 81420 NATIONAL DRIVE LA QUINTA, CA 92253 Contractor: SAUNDERS ENGINEERING CORP 3465 LA CAMPANA WAY, 44 PALM SPRINGS, CA 92262 (760)320-8254 Lic. No.: 751092 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 1/22/07 tJA N 2 2 2007 CITY OF LA QUINTA FINANCE DEPT. WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' -compensation insurance carrier°and policy number are: Carrier AMERICAN HOME Policy Number WC 71 31 82 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the La or Code, I shall forthwith comply with those provisions. tE5 e:� licant: WARNING: FAILURE TO SEC E WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF. COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city a d`coun[y ordinances a d'state laws relating to building con tion, and hereby authorize representatives of s county to enter up the above-mentioned property for inspectio oses. Date ZZ-0� Signature (Applicant or Agent): Application Number. 07-00000196 Permit BLDG POOL PERMIT Additional desc . Permit Fee. . 234.00. Plan Check Fee .. 152.10 Issue Date . . . . Valuation 23000 Expiration Date 7/18/07 Qty Unit Charge Per Extension BASE FEE 45.00 21.00 9.0000 THOU BLDG 2,001-25,000 189.00 Permit . . . MECH POOL Additional desc . Permit Fee . . . . 26.00 Plan Check Fee 6.50 Issue Date . . . Valuation . . 0 Expiration Date 7/18/07 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 11.0000 EA MECH FURNACE >100K 11.00 Permit . . . ELEC POOL PERMIT -RES Additional desc . Permit Fee . . . . 45.00 Plan Check Fee 11.25 Issue Date . . . . Valuation . . . . 0 Expiration Date 7/18/07 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 30.0000 EA ELEC PRIVATE SWIMMING POOL 30.00 Permit . . PLUMBING Additional desc . Permit Fee . . . . 33.00 Plan Check Fee 8.25 Issue Date . . . . Valuation . . . . 0 Expiration Date 7/18/07 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 6.0000 EA PLB FIXTURE 12.00 , 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 ------------------------------------------------------------------------- Special Notes and Comments --- POOL/SPA. ALARMS/BARRIERS SHALL BE IN LQPERAIIT Application Number 07L00000196 ----------------------- Special Special Notes and Comments -- ------------------------ - ------ PLACE AT PRE -PLASTER INSPECTION. EQUIPMENT ENCLOSURE NOT.INCLUDED Fee summary Charged Paid Credited Due ------- ---------- Permit Fee.Total 338.00 .00 ---------- .00 ---------- 338.00 Plan Check Total 178.10 .0'0 .00 178.10 Grand Total 516.10 .00 .00 516.10 LQPE"11T y�c co w,>% Voo C- So Y). j Ale s- 3-7 I �7 x� • • • Bin # City of La Quinta Building w Safety Division P.O. Box 1504, 78-495 Calle Tampico Permit #1,a Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Project Address: t < 1_ -zc- ic->P R Owner's Name: -�- LA p� I A. P. Number: Address:* Aijc> 0 MONAL. t(Z Legal Description: //�� ��qq Cont �{r71" ` p� \j 1I%14 Pe® Cin•. ST. Zip: - (-Quin-%A CA Ct 2.2CJ� Telephone: Z�j vTI ^ Address: �cA Project Description: Citi•. ST. Zip: fit` W -S y 92(01- % P L. N C— Telephone: ,T100 :::: State Lic. Arch.. Engr.. Designer:5UMija2i Address: Jr -JIN City, ST. Zip: Telephone: P State Ltc. 4. Je- Construction on Tv e. Occupancy: .P . Pr �e o ct n e circle one): Neje J . P ( 1 Add'n Alter Repair Demo Name of Contact Person: to—RI A Sq. Ft.: .4-7%> Stories: ;q Units: Telephone # of Contact Person: - ep0 -7 Estimated Value of Proiect: APPLICANT: DO NOT WRITE BELOW THIS LINE K Submittal Req'd Rec'd I TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cates. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Cales. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2nd Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up SALL H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees LABONIA —12.28.06 r 81-420 NATIONAL DRIVE LA QUINTA, CA 92253 Y` Project Manager: JOHN BARNETT DIMENSIONS: POOL SPA l Length: 36'0" 1010" Width: 17'0" 7'0" Surface Area (approx): 473 sq. ft. 57 sq. ft. Perimeter (approx): 98 ft. 28 ft. Depth: 3' to 6' to 3'6" 42" max. SPA SPECIFICATION: +18" RAISED SPA, 7 LF QZT STACK STONE SPILLWAY,QZT EXTERIOR FINISH, SMOOTH CONCRETE CAPSTONE, PEBBLE INTERIOR F1NSH, 9 JETS, AT ALTERNATING BACK HEIGHTS. DEMO WORK: Remove and Replace Wall for Access MASONRY: Dam Wall: 7 LF QZT Stacked Stone Spillway Boulders: 5 TO 6 - 24"BOULDERS PER PLAN FINISHES: Pool and Spa Finish: GEMSTONE BLEND PEBBLE FINISH Waterline Tile: 126 LF (Selection'from group l thru 3) Raised Stone: 45 SF Hi -Desert QZT for spa DECKING: Decking: 640 SF Colored Concrete w/light broom or salt finish Includes soil preparation per PGA West guidelines. Cantilever Edge: 117 LF California Edge 55 LF Umbrella Sleeves: 4 PLUMBING: Extra Spa to Equipment: 25 LF Raised Spa Bypass w/ck valve: Yes Dedicated Vac Line: Yes Gas Line: 175 LF All EQUIPMENT: Pump(s): 2- 2.0 HP Hayward Tri -star Filter: 525 SQ FT Hayward Swim Clear Cartridge Heater: 400,000 BTU Hayward Lo-NOx Controller: Hayward PS -4 In-home controller w/ remote. Purification System: Salt included w/ PS -4 controller Pool Light: Two -- 400 Watt Hayward Color -logic Digital .Spa Light: One -- 100 Watt Hayward Color -logic Digital Landscape: All Landscape Repairs by CVP MISC. SPECIFICATIONS: Buyer is aware that oral representation or expression by either party is not binding unless detailed and signed by buyer and seller. Alarms and gate springs to City code. Any additional colored concrete will be priced at $5.25 per square foot JV Change Order Date Revision (printed BOLD in specifications) A RE- INSPECT!ON FEE OF $30 VJII L RE CH WE'GED IF THE APPROVED -`L ANS AND JOB CARD ARE NOT ON THE SITE FOR A SCHEDULED INSPECTION. SEE PLAN ON REVERSE SIDE NO D(CEPTIONS! �C�TY OF LA C�JI"VTA U1LDlIVG &SAFETY DEPT. !APPROVED 1i 50-778-270 >TRUCTI 0 760-320-3667 FAX 3465 La Campana Way #4 Palm Springs, CA 92262 License No. 779165 PI 11'5 +18" RAISED SPA SPA 918 7 LF QZT STACK STONE SPILLWAY 24"B ULDERS 57 SF QZT EXTERIOR FINISH 28 LF SMOOTH CONCRETE CAPSTONE P/ /5 TO 6 PER PLAN 9 JETS AT ALTERNATING BACK HEIGHTS +18" -18" BENCH 3 +18' 5 TO 6 PER PLAN FOUR UMBRELLA SLEEVES PER PLAN, FOR PLACEMENT SEE PROJECT MANAGER 5, .EXISTING 2' 38'10 FXIS�TING 6'-� GAS LINE RUN: 195' FROM GAS MAIN TO 400,000 B.T.U. GAS HEATER USING 2" PIPE HEATER PUMP FILTER 23'4 P/L l BOB CAT DIG ACCESS THIS SIDE DEMO WALL FOR ACCESS AND REBUILD AFTER CONSTRUCTION Existing Air Conditioners P/L