AR (12-0168)f � • 1�1�
P.O. BOX 1504 ^�
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA. 92253 BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
CAppljcation Number: 12 - 00000168
Property Address: 51675 AVENIDA NAVARRO
APN: 773-144-021-9 -000000-
Application description: ADDITION - RESIDENTIAL
Property Zoning:' COVE RESIDENTIAL
Application valuation: 10000
Applicant: Architect or Engineer:
-------------------- 7 ------------------------------
. LICENSED CONTRACTOR'S DECLARATION �.
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the B i ss and Professional ode, nd my License is in full force and effect.
License Class: B ense o.: 926190
-/
'Date'Contrac
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve; demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. -7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_ 1 I am exempt under Sec. , B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec.. 3097, Civ. C.)•
Lender's Name:
Lender's Address: -
LQPERMIT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
LTJ
Owner: ' I MAY
AfiY O
RW REAL ESTATE, INC.1U 2012
52700 AVENIDA ALVARA4DO
LA QUINTA, CA 92253 CITYO_FU
0ufalra
Contractor:
HUITRON CONSTRUCTION
50427 RIGO COURT•
COACHELLA, CA 92236
(760)398-3227
Lic. No.: 926190
4/26/12.
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations: '
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
_ I have and will. maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation'
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 0013718-2011
I certify that, in the performan 'e of the work for which this permit is issued, I shall not employ any '
person in any manner s as o become subject to the workers' compensation laws of California,
and agree that, if I sho d comes bject to the work s' co ensation provisions of Section
3700 of the labor Co , I s all fort ith comply it those rovisions.
Date.
Applicant:
WARNING: FAILURE TO SECURE ORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRI NAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITI N TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit. -
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance 1buildig
t, or cessation of woifor0 days will subject
permit to cancellation.
I certify that I have read this application and state thnformation is correct.to c ply with all
city and county ordinances and state laws relating totruLnpurposes.
nd hereby re esentatives
of this county to enter upon the above-mentioned prec
D..5-7 -12'Signature (Applicant or Agent):
f
Application Number . . . . . 12-00000168
------ Structure Information 84SF ADDITION/VB/RES-3/CL A -FR [ENG] -----
Other struct info CODE EDITION 2010
FLOOD ZONE NO
1ST FLOOR SQUARE FOOTAGE 84.00'
----------------------------------------------------------------------------
Permit . . . BUILDING PERMIT
Additional'desc .
Permit Fee 117.00 Plan Check Fee 76.05
Issue Date . . Valuation 10000
Expiration Date 10/23/12
Qty Unit Charge Per Extension
BASE FEE 45.00
8.00 9.0000 THOU BLDG 2,001-25,000 72.00
Permit . . ELECT - ADD/ALT/REM
Additional desc .
Permit Fee . . . . 17.94 Plan Check Fee 4.49
Issue Date Valuation . . . . 0
Expiration Date 10/23/12
Qty Unit Charge Per Extension
BASE FEE15.00
84.00 .0350 ELEC'NEW RES - 1 OR 2 FAMILY 2.94
Permit MECHANICAL
Additional desc .
Permit Fee 19.5.0 Plan Check Fee 4.88
Issue Date Valuation . . . . 0
Expiration Date 10/23/12
Qty Unit Charge Per Extension
BASE FEE 15.00
.1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50
--------------------------------------------------
Special Notes and Comments
84SF ADDITION AND REMODEL AT (2) REAR
BEDROOMS/VB/RES-3/CLASS A [ENGINEERED]
THIS PERMIT DOES NOT INCLUDE ALTERATION
TO'EXISTING FRAMING OR MEP THROUGHOUT
REST OF THE DWELLING. 2010 CALIFORNIA
BUILDING CODE.
April 26; 2012 4:42:48 PM AORTEGA
---------------------------------------------------7
Other Fees . . . . .•. . . BLDG STDS ADMIN (SB1473) 1.00
LQPERMIT
LQPERMIT
s
Application Number
. . . . .
12-00000168
---------------------------------------
Other Fees . . . .
. . . . .
-------------------------------------
ENERGY REVIEW
FEE
7.61
STRONG MOTION
(SMI) - RES
1.00
Fee summary
Charged
Paid Credited
Due
Permit Fee Total
154.44
.00
.00
154.44.
Plan Check Total
85.42
.00
.00
85.42
Other Fee Total
9.61
.00
.00
9.61
Grand Total
249.47
.00
.00
249.47
LQPERMIT
s
Bin
Permit #`
J2�
I
Project Address:
:.. .
CkY Of U Quithta
RalkUpg 8L'Sarety Division .. .
P.O. Sox. iSO4, 78 -.4.95 Calle Tampico .:. .
L -Quinta, CA 92253 -:(760) 777-7012
Buildink Permit -AOpffcatlonand Tracking Sheet
,pr Owner's Name:. 11 ,,
WTA
A. P. Number. ` `N O�
Address: 5 �►li�h At V rAV�
Legal Description:
City, ST, Zip:...
Contractor..
0 J i�
Telephone: �.
Address: Q�a
\ Cx
Project Description:
City, ST, Zip: � �0 �� ���
Telephone: ••L
State Lie. #: q City Lic. #;n1
Arch., Engr., Designer:
`� 01�J r �n .In��+�r
�
, Ukv\
SLA -V C� wa
Address:
t OO M
City., ST, Zip:
p�3
Telephone:
State Lic. #:
Name of Contact Person:
XSq.
Construction Type:. Occupancy: qx—
Project type (circle one): New dd'n Alter Repair Demo
FL; \�1�� # Stories: #Units:
Telephone # of Contact PersVr7
Estimated Value of Project � b ,. J
APPLICANT: DO NOT WRITE BELOW THIS. UNE
#
Submittal
Plan Sets
Req'd
Recd
TRACMG PER MF FEES
Plan Check submitted Item Amount
Structural Calcs.
Reviewed, ready for corrections' ry Plan Check Deposit. .
Truss Calcs•
Called Contact Person Plan Check Balance
Title 24 Calcs.
Plans picked up00,
Yy I. construction .
Flood plain plan'
Plaits resubmitted,. ul� Mechanical
Grading plan
211 Review, ready for co, recti Electrical
Called CoutactPerson bing
Subcontactor List
Grant Deed
Plans picked up .
H.O.A. Approval
Plans resubmitted. ing
IN HOUSE:-
JGrad
''d Review; ready for correedoas/issaeoper Impact Fee
Planning Approval
Called Contact Person .P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees 12941
3I'5 1 LAW Ric,
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 84 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Exempt - Gustavo Huitron
Name on the check
BY Dr. Sharon P. McGehee
Superintendent
Check No.
Telephone 760-457-9960
Funding Exempt
L.
Fee collected /exempt d by Sha CG vre,}� Payment Recd err 0.00 -
ioVe'r/Under
iP �
Signature ?' `� �J ' `` }
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees
or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
CERTIFICATE OF COMPLIANCE
Desert Sands Unified. School District
4�J�1Fiscyo
47950 Dune Palms Road
Z o
¢BERMUDA DUNES �
Date 5/7/12
La Quinta, CA 92253
En RANCHO MIRAGE
�. INDIAN WELLS
No. 31268
(760) 771-8515
LM
�' P'°UINT
INDIO
Qy�
0
Owner RW Real Estate
APN #
773-144-021
Address 51675 Avenida Navarro
Jurisdiction
La Quinta
City La Quinta Zip
Permit #
Tract #
No. of Units
1
Type Residential Addition
Lot # No. Street
S.F. Lot # No.
Street S.F.
Unit 1 51675 Avenida navarro
84 Unlit 6
Unit 2
Unit 7
Unit 3
Unit 8
Unit 4
Unit 9
Unit 5
Unit 10
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered
patiostwalkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 84 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Exempt - Gustavo Huitron
Name on the check
BY Dr. Sharon P. McGehee
Superintendent
Check No.
Telephone 760-457-9960
Funding Exempt
L.
Fee collected /exempt d by Sha CG vre,}� Payment Recd err 0.00 -
ioVe'r/Under
iP �
Signature ?' `� �J ' `` }
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees
or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Joey Arsanto Res. Remodel/Addition
51675 Avenita Navarro APN#. 773144021
La Quinta, CA 92253
Project Designer:
Angel Gerardo
52935 Avenita Mendoza
La Quinta, CA 92253
760-333-6374.
Report Prepared by:
Gina Rose -Starkey
EQS, Inc.
42335 Washington St. #F-330
Palm Desert, CA 92211
760-218-3350
CITY -OF LA C UINTA
BUILDING & SAFETY DEPT,
APPROVED
FOR CONSTRUCTION
DATE Zdti BY
0
IN,
Job Number:
Date:
2/21/2012
FEB 2 4 2012
The EnergyPro computer program has been used.to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro5.1 by Ener Soft User Number: 5862 RunCode: 2012-02-21T16:00:17 /D:
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Summary 8
J.
EnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 5862
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Joey Arsanto Res. Remodel/Addition
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
2121/2012
Project Address
51675 Avenita Navarro APN# 773144021
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
1,332
Addition
84
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity (ft) Features see Part 2 of 5) Status
Wall Wood Framed R-15 892 Existing
Slab Unheated Slab -on -Grade None 1,248 Perim = 128' Existing
Roof Wood Framed Attic R-19 1,248 Existing
Wall Wood Framed R-15 184 New
Slab Unheated Slab -on -Grade None 84 Perim = 24' New
Roof Wood Framed Attic R-19 84 New
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
Rear (W) 76.0 0.500 0.45 none none Bug Screen New
Right (N) 28.5 0.710 0.60 none none Bug Screen Existing
Front (E) 44.0 0.710 0.60 none none Bug Screen Existing
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback Existing
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
HVAC System Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
Ener Pro 5.1 by EnergySoft User Number: 5862 RunCode: 2012-02-21T16:00:1 ID:
Page 3 of 10
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
Joey Arsanto Res. Remodel/Addition
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
1212112012
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HIGH MASS Design - Verify Thermal Mass: 804.0 ft Exposed Slab Floor, 3.500" thick at Exisitng House
HIGH MASS Design - Verify Thermal Mass: 444.0 ft2 Covered Slab Floor, 3.500" thick at Exisitng House
HIGH MASS Design - Verify Thermal Mass: 84.0 ft2 Covered Slab Floor, 3.500" thick at Addition
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
M
Ener.gyPro 5.1 by EnemySoft User Number- 5862 RunCode: 2012-02-21T16:00:1 ID: Page 4 of 10
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Joey Arsanto Res. Remodel/Addition
❑ Multi Family m Existing+ Addition/Alteration
2121/2012
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/Wt r
Space Heating 7.31 5.19 2.13
Space Cooling 138.11 122.79 15.33
Fans 30.67 27.30 3.37
Domestic Hot Water 22.01 22.01 0.00
Pumps 0.00 0.00 0.00
Totals 198.12 177.29 20.83
Percent Better Than Standard: 10.5
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (E) 320 44
Fuel Available at Site: Natural Gas (S) 288 0
Raised Floor Area: o (tM 320 76
Slab on Grade Area: 1,332 (N) 296 29
Average Ceiling Height: 8.0 Roof 1,332 0
Fenestration Average U -Factor: 0.60 TOTAL: 149
Average SHGC: 0.52 Fenestration/CFA Ratio: 11.1
REMARKS
J
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that -the documentation is accurate and complete.
Documentation Author
Company EQS, Inc. }
Address 42335 Washington St. #F-330 Name Gina Rose -Starkey 2/21/2012
City/State/ZipCity/State/Zip Palm Desert, CA 92211 Phone 760-218-3350 Si ned Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Angel Gerardo
Address 52935 Avenita Mendoza Name Angel Gerardo 2
City/State/Zip La Quinta, CA 92253 Phone 760-333-6374 Signed License # Date
Ene Pro 5.1 by EnerqySoft User Number: 5862 RunCode: 2012-02-21T16:00:1 ID: Page 5 of 10
Z
CERTIFICATE OF COMPLIANCE: Residential
(Part 4 of 5) CF -1 R
Project Name
Joey Arsanto Res. Remodel/Addition
Building Type m Single Family
❑ Multi Family
❑ Addition Alone
m Existing+ Addition/Alteration
Date
2/21/2012
OPAQUE SURFACE DETAILS
'
Surface
Type Area
U- Insulation
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status
Joint Appendix
4 Location/Comments
Wall
64
0.095 R-15
180 90 Removec 4.3.1-A4
Exisitng House
Wall
192
0.095 R-15
180 90 Existing
4.3.1-A4
Exisitng House
Wall
156
0.095 R-15
270 90 Existing
4.3.1-A4
Exisitnq House
Wall
268
0.095 R-15
0 90 Existing
4.3.1-A4
Exisitng House
Wall
276
0.095 R-15
90 90 Existing
4.3.1-A4
Exisitng House
Slab
804
0.730 None
0 180 Existing
4.4.7-A 1
Exisitnq House
Slab
444
0.730 None
0 180 Existing
4.4.7-A1
Existing House
Roof
1,248
0.048 R-19
0 0 Existing
4.2.1-A 16
Exisitng House
Wall
96
0.095 R-15
180 90 New
4.3.1-A4
Addition
Wall
88
0.095 R-15
270 90 New
4.3.1-A4"
Addition
Slab
84
0.730 None
0 180 New
4.4.7-A 1
Addition
Roof
84
0.048 R-19
0 0 New
4.2.1-A16
Addition
t
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor SHGC
Azm Status Glazing Type
Location/Comments
1
Window
40.0 0.710 NFRC 0.60 NFRC 180 Removed Existing
Exisitng House
2
Window
53.3 0.710 NFRC 0.60 NFRC 270 Removed Existing
Exisitng House
3-
Window
20.0 0.500 NFRC 0.45 NFRC 270 New Minimum
Exisitng House
4
Window
13.8 0.710 NFRC 0.60 NFRC 270 Removed Existing
Exisitng House .
5
1 Window
40.01 0.500 NFRC 1 0.45 NFRC 1 270 New Minimum
Existing House
6
Window
4.5 0.710 NFRC 0.60 NFRC 0 Existing Existing
Existing House
7
Window
6.0 0.710 NFRC 0.60 NFRC 0 Existing Existing
Exisitng House
8
Window
18.0 0.710 NFRC 0.60 NFRC 0 Existing Existing
Existing House
9
Window
20.0 0.710 NFRC 0.60 NFRC 90 Existing Existing
Exisitng House _
10
Window
24.0 0.710 NFRC 0.60 NFRC 90 Existing Existing
Existing House
11
. Window
16.0 0.500 NFRC 0.45 NFRC 270 New Minimum
Addition
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value '
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Window
Exterior Shade Type SHGC H t F Wd
Ove hanq
Len H t LExt RExt
Left Fin
Dist I Len
Ri ht Fin
H t Dist Len H t
1
Bug Screen
0.76 3.0 8.0 2.0 0.1 2.0 2.0
2
Bug Screen
0.76
-
_
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
a
8
Bug Screen
0.76
'
9
Bug Screen
0.76
-
10
Bug Screen
0.76
11
Bug Screen
0.76
A
EnergyPro
54 by Ener Soft User Number- 5862
RunCode: 2012-02-21T16:00:1
ID:
Page 6 of 10
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R
Project Name
Joey Arsanto Res. Remodel/Addition
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
2121/2012
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area
New Existing Altered Removed Volume Year Built
HVAC System Exisitng House
1,248
9,984 1980
Addition
84
672
Totals 841 1,2481 01 01
1
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
HVAC System 1 Central Furnace
80% AFUE Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
System Name Heating
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
HVAC System Ducted
Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
❑
WATER HEATING SYSTEMS
S stem Name —Qty.
T e
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Default Gas Prior to 1999
1
Small Gas
Point of Use
28,000
50
0.53
n/a
n/a
Existing
MULTI -FAMILY WATER
HEATING DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
E
E
T
w o_
Hot Water Piping Length
ff
o
0 c
a —
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
O
HP
Plenum
Outside Buried
❑
❑
❑
❑
❑
❑
❑
❑
EnergyPro 5.1 by Ener Soft User Number. 5862
RunCode: 2012-02-21T16:00:1 /D:
Pae 7 of 10
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Joey Arsanto Res. Remodel/Addition
Date
2121/2012
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
§150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent LI -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculatinq sections of hot water pipes are insulated per Standards Table 150-B.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(i)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro5.1 by EnergySoR User Number: 5862 RunCode: 2012-02-21716:00:17 /D: Page 8 of 10
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Joey Arsanto Res. Remodel/Addition
2/21/2012
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porousinner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
§150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro5.1 by EnergySoft User Number: 5862 RunCode: 2012-02-21716:00:17 ID: Page 9 of 10
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Joey Arsanto Res. Remodel/Addition
1212112012
§150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be hi h efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoff User Number: 5862 RunCode: 2012-02-21716:00:17 /D: Page 10 of 10