Loading...
SFD (04-4114)�IG,Nfti 4 , X04 BUILDING & SAFETY DEPARTMENT �dNP.O. Box 1504. 4 (.760)1777-7012 `OFT '9 78-495 CALLS TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153 BUILDING PERMIT Application Number . . . . 04-0.0004114 Date 6/10/04 Property Address .. . . . . . 52436 AVENIDA NAVARRO APN: 773-275-.009-14 -000000- Application description . . . DWELLING 7. SINGLE FAMILY DETACHED Property Zoning COVE RESIDENTIAL . Application valuation 112268 Owner Contractor' LAM LEONARD LAM 111 CHELSEA CIR PALM DESERT CA 92260 ----------- ----------------- Structure Information =------.------------------ Constructi.on;:Type,. _ ,:.:.:;;. �;TY.PE.V - NON; RATED. :;,•,,.2 Occupancy Type- DWELLG/LODGING/CONG <=1.0 Flood Zone NON -AO FLOOD ZONE Other struct info CODE EDITION 2001 CBC # BEDROOMS 3.00 FIRE __SPRINKLERS _ _ �_ NO GARAGE SQ FTG __. 429.00 PATIO SQ FTG 16:00 NUMBER'OF UNITS 1.00 FIRST.FLOOR SQ -FTG 1812.00 ------------------------------------------------------------------------------ Permit• . . . BUILDING PERMIT Additional desc Permit -Fee 685.00 Plan Check Fee 195.25 Issue Date Valuation .112268 Qty Unit Charge Per Extension BASE FEE 639.50 13.0.0 3.5000 THOU BLDG 100,001-500,000 45.50 ---------------------------'----------------------------`=----=----------- -- Permit . . .. . . . MECHANICAL Additional desc Permit Fee 59.00 Plan Check Fee 14.75 Issue Date Valuation . . . 0 Qty Unit Charge Per 1.00 1.00 3.00 BASE FEE 9.0000 -EA MECH FURNACE <=100K 9.0000 EA MECH B/C <=3HP/100K BTU 6.5000 EA MECH VENT FAN Extension 15.00 9.00 '9.00 19.50 P.O. BOX 1504 • '�C��� 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 44 BUILDING & SAFETY DEPARTMENT Application Number: 0^4/• Applicant: Applicant's Mailing Address: VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760)777-7153 Date: _ _ to - /0 Oma/ Architect or Engineer: Architect or Engineer's Address: Lic. No.: BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class License No. Datel�J `1 Contractor O/V�PC �/ LAM11 y OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or.that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure Is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his.or her own employees, provided that the improvements are not Intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. BA P.C. for this reason Date WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier - Policy Number I certify that, in the performance of the work for which this permit is issued, I shall not employ any person In any manner so as to become subject to the workers' compensation laws of California, and agree that, i I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. "Date Applicant WARNING: FAILURE TO SECURE WORKERS' COMPENSATION CVERfCG UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLAR 0,000), IN ADDI ION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST„ TTORNEY'S FEES. . CONSTRUCTION LENDING AGENCY hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work Is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnity and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work Is not commenced within 180 days from date of issuance of such -permit, or cessation of work for 180 days will subject permit to cancellation. certify that I have read this application and state that the above information Is corre�. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the a�ove-mentioned property for inspection purposes. bate4LLSignature (Applicant or Agent): Page Application Number 04-00004114 Date .2 6/10/04 Qty Unit'Charge Pere Extension 1.00 6.5000 EA MECH EXHAUST HOOD. 6.50 ------------------------ Permit . . .. ----------------------------------------------------- . . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee 102-00 Plan Check Fe'e,. 25.50. Issue Date Valuation 0 Qty Unit Charge P6:r Extension BASE FEE 15.00 1812.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 63.42 429.00 0200 ELEC GARAGE OR NON-RESIDENTIAL 8.58 1.00 15-0000 EA ELEC TEMPORARY POWER POLE 15.00 ----------------------------------------------------------------- ---------- Permit . . . . . . PLUMBING Additional desc Permit Fee . . . . 134.25 Plan Check Fee 33.56 Issue Date Valuation . . . . 0 Qty Unit Charge Per "Extension BASEFEE15.00 11.00 6.0000 EA PLB FIXTURE 66.00. 1.00 15.0000 8A PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM .9.00 5.00 .7500 EA PLB GAS PIPE >=5 3.75 1.00 15.0000 EA PLB GAS METER 15.00 ----------------------------------------------------------------------------- Permit . . ... . . GRADING PERMIT Additional desc Permit Fee . . . . 15.00 Plan Check Fee ..00 Issue Date . . . . Valuation 0 Qty Unit Charge Per Extension ------------------------------------------------------------------------------ BASE FEE 15.00 Special Notes and Comments 1812 S.F. SFD PERMIT DOES NOT'INCLUDE BLOCK WALLS, POOL/SPA OR DRIVEWAY APPROACH Page 3 Application Number . . . . . 04-000.04114 Date 6./10/04. ----------------------------------------------------------------------------- Other Fees ... . . . . . . ART IN PUBLIC PLACES -RES .00 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 44.53 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE 00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 COVE PRECISE PLAN FEE 100.00 STRONG MOTION.(SMI) - RES 11.22 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00. Fee summary Charged Paid Credited Due Permit Fee Total 995.25 .00 .00' 995.25 Plan Check Total 269.06 .00 00 269.06 Other Fee Total 2560.75 .00 .00 2560.75 Grand Total 3825.06 .00 .00. 3825.06 CERTIFICATE OF COMPLIANCE Desert Sands'Unified School District 47950 Dune Palms Road Date 6/23/04 La Quinta, CA 92253 No. 26086 (760) 771-8515 4���1> i�sCN C) BE Q BERMUDA DUNES Ln RANCHO MIRAGE Nr INDIAN WELLS b PALM DESERT y LA QUINTA ,IQIN0 y✓ O Owner Leonard Lam APN # 773-275-009 Address Jurisdiction La Quinta City Zip Permit # Tract # Study Area Type Single Family Residence No. of Units 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 52436 Avenida Navarro 1812. Unit 6 Unit Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees'imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.24 X 1,812 S.F. or $4,058.88 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By OC/Washington Mutual- Leonard Lam Check No. 674222013 Name on the check Telephone 340-9882 Funding Residential By Dr. Doris Wilson Superintendent Fee collected McGilvrey i Payment Recd $4,058.88 So.00 Over/Under NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the DistrictCs) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting RC ' DISTRICT =-PLANNING. REVIEW. FORM Pift " ` , - - This form is to be used by CDD staff for review of- single family dwellings -in the RC ('Cove Residential) District per Section 9.50.090 'of the Zoning Code. Its purpose is -to determine: 1) that the proposed housing design does not duplicate the same architectural style of any house within 200 feet of the applicant, .and/or' 2) if there is a need for the applicant to file for Master Design Guidelines: If the applicant does need to file a Master Design Guideline, please transmit this information to the Building and Safety Department as.. part of your correction list. Please attach additional explanations as necessary. APPLICANT: keo Yla.lrcf Lam SITE ADDRESS: i Na 1% -IVO APN 7q3- o�� - D0� CASE NO.: 97� LEGAL: LOT j BLOCK UNIT S.C.@V.L.Q. CHECK AND APPROVED.BY: DATE: Inform the assigned Building plan checker upon your. assignment to this case. The CDD Executive Secretary maintains a log book to track applications. and assign case numbers. REQUIRED ITEM Y N COMMENT/CORRECTION Verify legal and APN information Consistent with MDG on file (as applicable) .MDG filing required (5 filings since 9/3/98) Architectural variety within 200 feet of the surrounding area: ro ed b Planning Commisslort e -so ity Council `---�- . itials6 '..�----- ase No. _ Architectural design features 11 Wifh' Conditions Other Requirements: TITLE 24 REPORT Title 24 Report for: Leonard Lam Plan 1812 - All Orientations La Quinta, CA Project Designer: Report Prepared By: Joan D. Hacker Insu-Form Inc. 68255 Corta Road Cathedral City, CA 92234 (760) 324-0216 - - - _CITY OF LA QUINTA BUILDING & SA M Y DEPT* APPROOuc ��R CONST Job Number: t)A '� .Sr ' d 72 ; Date: 5/26/2004 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. EnergyPro 3.1 By EnergySoft Job Number: User Number. 2655 1 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist FormC-2R Computer Method Summary HVAC System Heating and Cooling Loads Summary Room Load Summary 1 2 3 6 8 12 13 i t EnergyPro 3.1 By EnergySoft Job Number. User Number. 2655 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Leonard Lam 5/26/2004 - Project Title Date Plan 1812 - All Orientations La Quinta Project Address Building Permit # Ihsu-Form Inc. (760) 324-0216 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 1,812 ft2 Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 1,812 fl? Building Type: (check one or more) , X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: All Four Orientations Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Const. Component Frame Assembly Location/Comments Type Type` U -Value (attic, garage, typical, etc.) Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation R-13 Wall (W.13.2x4.16) Wood 0.081 Exterior Wall R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof FENESTRATION Shading npvirrpc Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Front 20.0 0.55 0.45 Bug Screen ❑ X❑ ❑ X❑ Front 15.0 0.43 0.45 Bug Screen ❑ X❑ ❑ X❑ Front 30.0 0.58 0.45 Bug Screen ❑ X❑ ❑ X❑ Left 54.0 0.58 0.45 Bug Screen ❑ X❑ ❑ X❑ Left 40.0 0.55 0.45 Bug Screen ❑ X❑ ❑ X❑ Rear 69.4 0.58 0.45 Bug Screen ❑ X❑ ❑ X❑ Rear 16.0 0.43 0.45 Bug Screen ❑ X❑ ❑X❑ Right 58.0 0:58 0.45 Bug Screen ❑ Q ❑ Q ❑ -❑ ❑ ❑ 1-1 El ❑❑ El R Run Initiation Time: 05/26/04 11:07.41 Run Code: 1085594861 Ene Pro 3.1 B Ener Soft User Number: 2655 Job Number: Pa e:3 of 13 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Leonard Lam 5/26/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Central Furnarre 80% AFUE Ducts in Attic 42 Setback Living Zone Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location heat pump, evap. cooling) (SEER) (attic, etc.) Duct Thermostat Location / R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4 2 Sethack Living 7nne WATER HEATING SYSTEMS Rated 1 Tank Energy Facti 1 External Water Heater Water Heater Distribution # in Input Cap. or RecoveryStandby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A.O SMITH FPS -50-224 Small Gas Standard 1 43,000 _ so 0.60 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS %.vmrLtAN ,t J I A I Cnflr- V 1 This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer orOwner(per Business & Professions Code) Documentation Author �.G Name: 0,A141�'f? LAM Name: Joan D. Hacker Title/Firm: 0 UVA/-6K Title/Firm: Insu-Form Inc. Address: /// CF/L-LSCA CW6t-8 Address: 68255 Corta Road M P SC-f?� " 17 �0 Cathedral City, CA 92234 Telephone: o 3 -4 gF Telephone: (760) 324-0216 Llc. #: (signature) (date) (sig tur) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature/stamp) (date) JEnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. PageA of 13 1 Certificate of Compliance: Residential (Addendum) CF -1 R Leonard Lam 5/26/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies JaDwu Ulf LIM aUCI-Udt y U1 LIM special Jusuncauon anu uocumentation suomitiea. Plan Field The HVAC System "Living Zone" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. X HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1086 sgft Covered Slab Floor, 3.50" thick at Living X HIGH MASS Design(see C -2R) - Verify Thermal Mass: 726 sgft Exposed Slab Floor, 3.50" thick at Living I X HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS iJl V41uol. 1 IIC IICRJ IOLVI IIIUbL UUGUIIIC.I L Lilt: IIew venncaDon anu oiagnosuc testing of mese measures on a rorm L;F-6R. Plan Field The HVAC System "Living Zone" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. t EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page:5 of 13 1 Mandatory Measures Checklist: Residential (Page 1 of .2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ❑ '§150(a): Minimum R-19 ceiling insulation. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value. ' 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ❑§ not apply to exterior mass walls). ❑ ' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. ❑ § 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. x ❑ § 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain = I X Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ❑§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. �( ❑ §150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMAC NA or ACCA. �( ❑§150(i): Setback thermostat on all applicable heating and/or cooling systems. X ❑ §1500): Pipe and Tank Insulation x 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number: Page:6 of 13 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. j DESIGNER 'ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) ix 1150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system l I that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not i fbe used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and I I drawbands. j 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other I than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building I cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. i 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. I 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually i operated dampers. j 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable I for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. i 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. i b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. IJ §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no ! continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) �� §118 (f): Cool Roof material meet specked criteria I i Lighting Measures I ❑ §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement �/ X allowed in Section 150(k)2.; and recessed ceiling factures are IC (insulation cover) approved. 3,1 By EnergySoft User Number. 2655 Job Number. Page:7 of 13 Computer Method Summary (Part 1 of 3) C -2R Leonard Lam 5/26/2004 Project Title Date Plan 1812 - All Orientations La Quinta Project Address Building Permit # Insu-Form Inc. (760) 324-0216 Documentation Author Telephone Plan Check/Date i Computer Performance 15 Field Check/Date Compliance Method (Package or Computer) Cimate Zone Source Energy Standard I Facing `• ( I Facing 0.93 ! Facing 34.58 Use (kBtu/sf-yr) Design North Margin ! East Margin ! j South Margin Space Heating 1.29 i 0.71 0.5811 0.76 0.531 0.98 0.32 Space Cooling 33.62 1 35.60 -1.981 I 35.38 -1.761 j 34.14 -0.52 Domestic Hot Water 13.88 12.10 1.791 1 12.10 1.79! 1 12.10 1.79 Totals 48.80 ; 48.41 0.391, 1 48.24 0.5(31, i 47.21 1.58 Facing BUILDING West Margin ' 0.93 0.36; 34.58 -0.96; i 12.10 1.791 47.60 1.191 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area I iving 7nne 1 R1 1819 1 on ronditionerl Setback _2 n/a OPAQUE SURFACES Solar Act. Gains I ype Area U -Val. Azm. Tilt Y / BUILDING COMPLIES X X This C -2R describes the front facing North occurrence of a four cardinal orientation analysis. Features are identical in all orientations. Total Conditioned Floor Area: 1,812 ft 11 ❑ ❑ ❑ Building Type: Single Fam Detached Floor Construction Type: ❑ Raised Floor 1 Xl Slab Floor Building Front Orientation: All Four Orientations Total Fenestration Area: 16.7% Number of Dwelling Units: 1.00 Total Conditioned Volume: 18,120 ft' Number of Stories: 1 Total Conditioned Slab Area: 1,812 ft BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area I iving 7nne 1 R1 1819 1 on ronditionerl Setback _2 n/a OPAQUE SURFACES Solar Act. Gains I ype Area U -Val. Azm. Tilt Y / N Form 3 Reference Location / Comments Wall 315 0.081 _a go Wall 316 0.081 go go X X ❑ R-13 Wall (W 13 ?x4 18) Living lone R-11 Wall ON 13_ x4 16) Living 7nne Wall 415 0.081 180 90 Wall 312 0-0-8-1 270 90 Rnnf 1.81_2 Q.028 270 0 11 ❑ ❑ ❑ R-13 Wall (W 1-3 4 16) I iving 7nne R 13 Wall (W 13 ?x4 16) Living 7nne R-38 Roof 38 9x14 16) living (R 7nne ❑❑ ❑❑ ❑❑� F-1 F-1 1-1 ❑❑ F-1 F-1 0 E Run initiation Time: 05126/0411.07.41 Run Code: 1085594861 3.1 By EnergySoft User Number: 2655 Page:8 of 13 Computer Method Summary (Part 2 of 3) C -2R Leonard Lam 5/26/2004 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 1_ 2 wiEront (Nom Window Front (North) 3 Window Front (North) 4 Window Front (North) 5 Window Left (East) 6 Window Left (East) L Window Left (East) 8 Window Left (East) 6 'V�l�dow Rear (Bout ) LQ Window Rear (South) " Window Rear (South) 12 Window Right (West) 13 14 window Window Right Right (West (West) 53.4 0.580 0.45 180 90 Milgard Windows ..Living Zone 16.0 0,580 0.45 180 90 Milgard Windows Living Zone 900 _0-5.a 045 _ 0 _9.Q Milgard Windows Livina_Zoae 6.0 0.430 0.45 0 90 Milgard Windows Living Zone 30.0 0.580 0.45 0 90 Milgard Windows Living Zone 9.0 0.430 0.45 0 90 Milgard Windows Living Zone 10.0 0.580 0.45 90 90 Milgard Windows Living Zone 40.0 0.550 0.45 90 90 Milgard Windows Living Zone 4.0 _0_QQ 0.45 90 90 Milgard Windows Living Zone 20.0 0.580 0.45 90 90 Milgard Windows Living Zone 53.4 0.580 0.45 180 90 Milgard Windows ..Living Zone 16.0 0,580 0.45 180 90 Milgard Windows Living Zone 16.0 0.430 0.45 180 90 Milgard Windows Living Zone 9.0 0.580 0.45 270 • 90 Milgard Windows Living Zone 40.0 0.580 0.45 270 _9Q Milgard Windows 1Lvbg Zone 9.0 0.580 0.45 270 90 Milgard Windows Living Zone I EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number. Page:9 of 13 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist Len Hgt 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen _ 0.76 4 Bug Screen _ 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen _ 0.76 12 Bug Screen 0.76 13 Bug Screen _ 0.76 14 Bug Screen 0.76 I EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number. Page:9 of 13 Computer Method Summary Distribution Type (Part 3 of 3) C -2R Leonard Lam Type (furnace, heat 5/26/2004 Project Title Duct Thermostat Location / Date THERMAL MASS FOR HIGH MASS DESIGN Comments Area Thick. Heat Ducts in Attic Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments -C-Qn-mete, Heavyweiahht_ 548.6. _3_50 —28. A9.8. n/a _� ivina one / Slah on Grade Concrete. Heavyweight 726 3_50 28 0_98 n/a 0 Living Zone / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Insul. Slab Perimeter 15 0.76 0.0 0 Living Zone Diameter Slab Perimeter 15. 0.76 p.Q _Q Living Zone HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80 QAFUE Ducts in Attic 4.2 Setback Living Zone Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Living Zone WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext A.O. SMITH FPS -50-224 Small Gas Standard 1 43,000 50 0.60 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Computer Method Summary (Addendum) C -2R Leonard Lam 5/26/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies :Pasea on the adequacy or ine special /ustmcation ana aocumentatlon suomittea. Plan I Field The HVAC System "Living Zone" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1086 sqft Covered Slab Floor, 3.50" thick at Living HIGH MASS Design(see C -2R) - Verify Thermal Mass: 726 sqft Exposed Slab Floor, 3.50" thick at Living r HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS NI wn+er. i me rimma racer must aocument the nein vermcation ana aiagnostic testing or mese measures on a Corm ct--6K. plan FField The HVAC System "Living Zone" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. i I EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 11 of 13 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY :1 !PROJECT NAME DATE I Leonard Lam 5/26/2004 !SYSTEM NAME FLOOR AREA Living Zone 1,812 ENGINEERING CHECKSSYSTEM LOAD ;Number of Systems 11, COIL COOLING PEAK !':COIL HTG. PEAK (Heating System 1 CFM (Sensible; Latent 1 CFM I Sensible Output per System 1 89,000 Total Room Loads j 1,942 35,8171 4,320! 720j 30,1151 Total Output (Btuh) 89,0001 Return Vented Lighting 1 01 i Output (Btuh/sqft) j 49.1 Return Air Ducts 1 1,7s1j 1 1,5061 !Cooling System Return Fan o 0 1 Output per System 61,5001 Ventilation 01 01 01; 01 01 jI Total Output (Btuh) 61,500 Supply Fan 01 I I Total Output (Tons) 1 5.1 Supply Air Ducts ( 1,7911 Total Output (Btuh/sqft) 1 33.9 TOTAL SYSTEM LOAD 39,3981 4,320 i 33,1271 1 Total Output (sgft/Ton) 1 353.6 ;Air System 1 HVAC EQUIPMENT SELECTION I CFM per System Airflow (cfm)1 1 2,0551 2,055 TRANE TTX060D 41,4741 14,155 89,000 Airflow (cfm/sgft) 1.13 1 Airflow (cfm/Ton) I 401.0 Outside Air (%) 0.0 Total Adjusted System Output (Adjusted for Peak Design Conditions) 41,474 14,1551 - 89,000 Outside Air (cfm/sgft) 0.00 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 69.3 OF 69.3 of 109.7 of Supply Air Ducts Outside Air ' 0 cfm Supply Fan Heating Coil 109.0 of 2055 cfm i ROOMS 69.3 of 70.0 of 1114- I Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 1111.0 /77.4°F 78.8/65.9OF 78.8/65.8°F 60.0/58.8OF Outside Air O Supply Air Ducts 7 0 cfm Supply Fan Cooling Coil 60.8 / 59.1 OF 2055 cfm ROOMS 52.1% R.H. 78.8/65.9 °F 78.0 / 65.6 OF ec Return Air Ducts `► ' EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page:12 of 13 ROOM LOAD SUMMARY PROJECT NAME Leonard Lam DATE 5/26/2004 SYSTEM NAME Living Zone FLOOR AREA 1,812 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK 'i COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Living Zone Living 1 1,942 35,817 4,320 1,942 35,817 4,3201 720 30,115 i i I i i i i i i I i PAGE TOTAL 1 1,942 35,817 4,320 720 30,115 TOTAL 1 1,942 35,817 4,320 720 30,115 EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page:13 of 13 FINISH Ff FMW 0un4a F 1 ryt NOTEDMWMI• FINISH Ff FMW 0un4a rr 3, t r i r J ✓ F s .�Sf::�r.• e krrti� �� � {• r �• f- NOTEDMWMI• 1 , - oil fool 9 y f.. .:.. • ♦ : - C id rr 3, t r i r J ✓ F s .�Sf::�r.• e krrti� �� � {• r �• f-