SFD (0309-012)LICENSED CONTRACTOR DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of
Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force and effect.
License # Lic. Class Exp. Date
Signature of Contractor % �d i /.✓ fa ._
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
( ) I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code).
() I am exempt under Section B&P.C. for this reason
Date Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm tinder'penalty of perjury one ofjthe following declarations-
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for,. by Section 3700 of. the Labor Code, for the
performance of the work for which this permit is issued. . .
( ) I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carrier Policy No.
0 TAT cF13N1) 134230.9
(This section need not be completed if the permit valuation is for $100.00 or less):
() I certify that in the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to become subject to the
workers' compensation laws of California, and agree that if I should become
subject to the workers' compensation provisions of Section 3700 of the Labor
ode, I shall forthwith comply with those provisions'��
ate: f,' .. a Applicant %
Warning: Failure to secure Workers' Compensation coverage is unlawful and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages, as provided for in Section 3706
of the Labor Code, interest and attorney's fees. ,
IMPORTANT Application is hereby made to the Director of Building and -Safety
for a permit subject to the conditions and restrictions set forth on his
application.
1. Each person upon whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit. issued as a result of this applicaton agrees to, & shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
correct. I agree to comply,with all City, and State laws relating to the building
construction, and hereby authorize representatives of this City to enter upon
the above-mentioned property for inspection purposes .
/Signature (Owner/Agent)'~ ��!'r" f✓r,�'� Date
PERMIT#
-:._w PERMIT
!�`�-BUILDING
DATE - VALUATION LOT ; �};rf) .� TRACT
JOB SITE -
APN
ADDRESS
57,340 MT01M
OWNER
CONTRACTOR/DESIGNER/FN INFER
J,>:T9V JJ.J' .3 J+n�W s: '•'. ' -
�'S7Y�r 1±dAkV...,S6.5'n CiVi:(+ud'+��h.raA�iV.'.A. c+�.m�a�
il
NaM.Dr.. FR'.F. p CA, A, 9 t P 604
PALM D S"31KRT CA 5+2264:;
USE OF PERMIT
i I �? ."i,Je St (Y dyLRivf"# ;7tJN.S Ih 1 �l fF.°%IT:;YSi: BLOCK 'KiiALLy PGOU SPA,
4.tai.`r.l�iar'���%A?+���IR�.ivANCH
�
�tA2.A�T�C�Cc�?t.34e'i' •A?0,�E1 �".�':�
}?E°'LRMT17.1e r"'�MM.i�"Y'
CONSTRUCTIaN PER, 10, 1 LI -00 �4 1$- 000
"r'R..M4 CHWX PIZ Zvi) 18N13CHANICA'.1,
F42
1� i1Fi5'fTN:1Fit 30-0000-li 9 -000 $133,00
STi1 ti•tc:< A+tg)'9:C)1`I FER RtSID 103-0130 41.000D91.1(11
� tt �:.Ui�e 14 o}?1 l t3'i ^ 4� • 2 C+�tt3 I N•. fig
7KVJ:LQP'j 'R, tWACT FU
-ms �y1:j0.flli
y
.
IA1 P11 !t3T°2a, "' RRIJC3=1:tW ARD PLA11 C11T.:c {•It
j� Irk D03 PP. Pflulo :i` ' ,.°O
',a9,zp.2.
a t�4n.1'J
U,
S�Q 10.2003.. xAL:f? $M'i;1°:37a 6 D$-° No
fE�!AC DEFT.. ,
RECEIPT
DATE
BY
DATE FINALED"'
SPECTO
INSPECTION RECORD
OPERATION
DATE
INSPECTOR
BUILDING
APPROVALS
Set Backs
—/ - O
Forms & Footings
Waste Lines _ O
Slab Grade
iGl a
Steel
d p
Roof Deck
Bond Beam
O.K. to Wrap
Sewer Lateral
Framing
a'l z2'
Insulation
G
Fireplace P.L.
Fireplace T.O.
Party Wail Insulation
Party Wall Firewall
Exterior Lath
Drvwall - Int. Lath
OPERATION DATE INSPECTOR
MECHANICAL APPROVALS
Underground Ducts
Ducts
Return Air
Combustion Air
Exhaust Fans
F.A.U.
Compressor
Vents
Grills
Fans & Controls
Appliances
Final
COMMENTS:
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp. Power Pole
Underground Conduit
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power G7_ A1__ A Q11-11 "7
Final
Utility Notice
Final
Final
Underground Plbg. Test
Final
POOLS - SPAS
BLOCKWALL APPROVALS
Gas Test
Electric Final
Waste Lines _ O
Steel
Set Backs
Electric Bond
Footings
I Main Drain
Bond Beam
I Aenroval to Covor
Appliances
Final
COMMENTS:
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp. Power Pole
Underground Conduit
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power G7_ A1__ A Q11-11 "7
Final
Utility Notice
Underground Electric
Underground Plbg. Test
Final
Gas Piping
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Lines _ O
Heater Final
'Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K. for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection
I Encapsulation
Gas Pivina
Appliances
Final
COMMENTS:
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp. Power Pole
Underground Conduit
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power G7_ A1__ A Q11-11 "7
Final
Utility Notice
0304-01Z 4 44
P.O. BOX 1504 APPLICATION ONLY
Building 78-495 CALLE TAMPICO
Address LA QUINTA, CALIFORNIA 92253
Owner
Mailing BUILDING: TYPE'CONST. OCC. GRP.
Address s%. A.P. Number 3' r3 — 5-0-5- •oDiL
Zip l Tel. Q
d -(Ayr— p� v
2 Z a 3 g- Legal Description
��. a[.1� 1"0 C� S
Contractor _ I 5 F -T
� Project Description
Address �r
Q
.Al tyZip Tel.. �O
l.'m i 2 1 6Q -:b- fy
State Lic. l City
& Classif.,g 6a S Q Lic. # 00 Sq. Ft. 7 No. No. Dw.
Arch., Engr., Size ��� Stories Units
Designer New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑
Address Tel.
City Zip State
Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licens d under Drovisions of Chapter 9 (commencing with Section
7000) of Divisi 3 of t us' fs Professions Code, and my license is in full f rce and '
effect. �7 �VC
-D i
SIGNATURE' a
DATE
OWNER -BUILDER DECLARATION Estimated Valuation
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a
permit to construct, alter, Improve, demolish, or repair any structure, prior to 'its Issuance also
requires the applicant for such permit to file a signed statement that he is licensed pursuant to PERMIT AMOUNT
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code. or that. he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit Plan Chk. Dep. so - 00
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).
I.: I, as owner of the property, or my employees with wages as their sole compensation, will Plan Chk. Bal.
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Const.
Code: The Contractor's License Law does not apply to an owner of property who
builds or improves thereon and who does such work himself or through his own employees. Mech.
provided that such improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of completion, the owner -builder will have the burden Electrical
of proving that he did not build or improve for the purpose of sale.)
I'I I, as owner of the property, am exclusively contracting with licensed contractors to con- Plumbing
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of property who builds or improves thereon, and who contracts for S,M,I-
such projects with a contractors) licensed pursuant to the Contractor's License Law.) 1 nil
I'7 I am exempt under Sec. B. & P.C. for this reason
Grading
Driveway Enc.
Date Owner InfrastnictUre
WORKERS' COMPENSATION DECLARATION LU
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Worker's Co pe aif Ins rance, or a ce 'fi co thereof. (Se .3800, Labor C'(q�]e.l FINANCE
Policy No���CompanyL�—
fl Copy is filed with the city. ❑ Certified copy is hereby furnished.
TOTAL
CERTIFICATE OF EXEMPTION FROM REMARKS
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less.)
I certify that in the performance of thg work for which this permit is issued, I shall not
employ any person in any manner so as to become subject to the Workers' Compensation
Laws of California.
Date Owner
NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become ZONE: BY:
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked. Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
CONSTRUCTION LENDING AGENCY Side Street Setback from Center Line
by affirm that there is a construction lending agency for the performance of the
work for this permit is issued. (Sec. 3097, Civil Code.) Side Setback from Property Line
Lender's Name
Lender's Address FINAL DATE INSPECTOR
This is a building permit properly filled out, signed and validated, and is subject to
expiration if work thereunder is s dad for 180 days.
I certify that I have read this applica nd state that the above information is correct. Issued by: Date Permit
I agree to comply with all city and county ances and state laws relating to building
construction, and hereby authorize represents sof this city to enter the above•
mentioned property for inspection purposes. Validated by:
Signature of applicant ate
Mailing Address Validation:
City, State, Zip
WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE
CERTIFICATE OF COMPLIANCE JFs(0,
Desert Sands Unified School District �4'?)
47950 Dune Palmi Road
q ¢BERMUDA DUNES
7 r
Date 9/10/03 La QUinta CA 92253 rn RANCHO MIRAGE d
{I INDIAN WELLS �.
No. 24940 (760) 771-8515 �,�
PALM
QUIN y
�INDIO JJ
Owner
David Peters
APN #
773-305-002 ,
Address
73-170 Amber St.
Jurisdiction
La Quinta
City
Palm Desert Zip 92260
Permit #
0309-012
Tract #
BLK140
Study Area
Type
Single Family Residence
No. of Units
1 -
Lot # No. Street S.F.
Lot # No.
Street S.F.
Unit 1 22
52540 Avenida Navarro 1527
Unit 6
Unit 2
Unit 7
Unit 3
Unit 8
Unit 4
Unit 9
Unit 5
Unit 10
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garageskarports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $2.14 X 1,527 S.F. or $3,267.78 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By C/C Untion Bank of California -David Peters Check No. 8371112
Name on the check Telephone 340-9844
Funding Residential
By Dr. Doris Wilson
Superintendent
Fee collected /exemp ed by Patricia Barbuzza
Signature rJ1_1 ' '
Payment Recd 1$0.00
$3,267.78 y Over/Under
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting
RECORDING RE(ftSTED BY:
COMMONWEALTH LAND TITLE COMPANY
12627JE
WHEN RECORDED MAIL THIS DEED AND,
UNLESS OTHERWISE SHOWN BELOW,
MAIL TAR STATEMENTS TO:
David A. Peters
Veronica M. Peters
73170 Amber Street
Palm Desert, CA 92260
M
S
U
PAGE
WE
DA
PCOR
NOCOR
SMF
"ASC.
A
R
U
COPY
LONG
_
REFUND
, NC.4G
i
EWA
APN:
GRANT T DIEED
773-305-002-3
oaa - 0 / 7
The undersigned grantor(s) declare(s):
Documentary transfer tax is $71.50
?;XX Computed on full value of property conveyed, or
Computed on full value less liens and encumbrances remaining at time ofsale.
Unincorporated area: ( ) City of and
FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged,
_.. Gabrie.l -Vi 1:lagomez and Elizabel..G_. Villagomez , husband and --wife as Joint .... tenants.
hereby GRANT(S) to
David A. Peters,and Veronica M. Peters, husband and wife as -joint tenants
the real property in the City of La Quinta, County of Riverside, State of California,
described as:
Lot 22, Block 140, Santa'Carmelita at Vale La Quinta, Unit 15, as per map recorded in
Book 18, Page 92 of Maps -
SEE "EXHIBIT A" ATTACHED HERETO
Dated March 7, 2003
State of California'
Count of JVG1 S/�� } S.S.
On 9. l T �
before me, fgwe,+_7- N l� OfQN r h�t4
personally appeared
..personally kfnown to me (or proved to me on
the basis of satisfactory,evidence) to be
whose name) "/are subscribed
the person
to the within instrument and acknowledged to
me that ha/_�/they executed the same in
bjg/Jiex-/their authorized capacity , and
that by hide-their,
he itmature 0 o the
instrument the person o ,o the entity upon
behalf of which the person& acted, executed
the instrument.
WITNESS my ha and icial seal.
Signature (This area for official notarial seal)
MAIL, TAX STATEMENTS iM
111111 illlii lilil 1111 Illlil II�i Illiili Ili lilll lifillll �4 �g y 2 of3����
.Gabriel Villagoluef,
Eliz el. G_. VillagoMe76
i
R
PAMELAJ. HOTT11Q. ,
Commission # 1310266
Notary Public - California
Riverside Ca=t
fly con-, a0res
r
A TITLE 24 REPORT
Title 24 Report for:
California Desert Construction
52540 Avenida Navarro
La Quinta, CA ;
Project Designer:
Report Prepared. By:
Joan D. Hacker
Insu-Form Inc.
68255 Corta Road '
Cathedral City, CA 92234
(760) 324-0216 CITY OF LA OUINTA
BUILDING & SAFM DEM
APPROVED
FOR CONSTRUCTION.
DATE
Job Number: oV'F14(5r
Date:
7/3/03
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards.
This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900.
EnergyPro 3.1 . By EnergySoft Job Number: User Number. 2655. '
TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Checklist
Form C -2R Computer Method Summary
HVAC System Heating and Cooling Loads Summary
Room Load Summary
Certificate of Comoliance: Residential (Part 1 of 2) CF -1R
California Desert Construction 7/3/03.
Project Title Date
52540 Avenida Navarro La Quinta
Project Address Building Permit #
Insu-Form Inc. (760) 324-0216 Plan Check / Date
Documentation Author Telephone
Computer Performance 15 Field Check / Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 1,527f? Average Ceiling Height: 10:0 ft
Total Conditioned Slab Area: 1,527 ft2
Building Type:
(check one or more)
X❑ Single Family Detached ❑ Addition
❑ Single Family Attached ❑ Existing Building
❑ Multi -Family ❑ Existing Plus Addition
Front Orientation: (West) 270 deg Floor Construction Type: ® Slab Floor
Number of Dwelling Units: 1.00
Number of Stories: 1 ❑ Raised Floor
Component
Type
Frame
Type
Const.
Assembly
U -Value
Slab On Grade
n/a
0.756
Slab On Grade
n/a
0.756
R-13 Wall w/1" EPS
Wood
0.059
Solid Wood Door
None
0.387
R-38 Roof (R.38.2x14.16)
Wood
0.028
FENESTRATION
Location/Comments
(attic, garage, typical, etc.)
Covered Slab w/R-0.0 Perimeter Insulation
Exposed Slab w/R-0.0 Perimeter Insulation
Exterior Wall
Exterior Door
Exterior Roof
Shading Devices
Type
Orientation
Area
Fenestration
Exterior .
Overhang Side Fins
SF
U -Factor
SHGC
Shading
Yes / No
Yes / No
Front
(West)
24.0
0.87
0.70
Bug Screen
x❑ ❑
❑ x❑
Left
(North)
20.0
0.87
0.70
Buq Screen
x❑ ❑
❑X❑
Rear
(East)
36.0
0.87
0.70
Bug Screen
x❑ E]
1:1 RX
(East)
7.0
0.50
0.65
Buq Screen
x❑ ❑
❑ x❑
Right
(South)
32.0
0.87
0.70
Buq Screen
X❑ ❑
❑ X❑
El 1:1
❑❑
El El
❑ ❑
El El
El F-1
1:1 1:1
1-1 F1
El F]
El F-1
El El
El
El El
El El
Run Initiation Time: 07/03/03 11:24:08 Run Code: 1057227848
EnergyPro
3.1 By Ener
oft
User Number: 2655
Job Number:
Pa e:3 of 10
'Certificate of Compliance: Residential (Part 2 of 2) CF -1 R
California Desert Construction 7/3/03
Project Title Date
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Equipment Minimum Distribution
HeatingType and Duct or
Type (furnace, heat Efficiency Location Piping Thermostat Location /
pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments
Cantml Fijrna(,a 80% AFUE Ducts in Attic 4.2 Setback Living Zone
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location Duct Thermostat Location /
heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type - Comments
Split Air Conditioner 12.0 SEER Ducts in Attic 42 Sethack Living 7nnp
WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External
Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul.
System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value
A.O. SMITH FPS -50-224 Small Gas Standard 1 43.000 _50 0.60 n/a n/a
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any
shading feature that is varied is indicated in the Special Features/Remarks section.
Designer or Owner (per Business & Prof ions Code)
Documentation Author
1V�
Name: � �7,49. Name: Joan D. Hacker
Title/Firm: Title/Firm: Insu-Form Inc.
Address: Address: 68255 Corta Road
Cathedral City, CA 92234
Telephone: 7 - Telephone: (760) 324-0216
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
(signature/stamp) (date)
Run Initiation Time: 07/03/03 11:24:08 Run Code: 1057227848
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:4 of 10
Mandatory Measures Checklist: Residential MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component specifications for the mandatory measures whether they
are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A If not applicable.
DESIGNER
ENFORCEWIEN
Building Envelope Measures
F'§150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value.
❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value.
.§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to
exterior mass walls).
❑ '§150(d): Minimum R-13 raised floor insulation in framed floors.
§ 150(1): Slab edge insulation - water absorption rate <= 0.3%, water vapor transmission rate <= 2.0 perm/inch.
❑X §118: Insulation specified or installed meets insulation quality standards. Indicate type and form.
FXJ §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified SHGC, and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
§150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
§150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
® §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue
damper and control;
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
X] §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
§150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
§150(i): Setback thermostat on all applicable heating and/or cooling systems.
§1500): Pipe and Tank Insulation
Al
1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16
combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5. Cooling system piping below 55 degrees F. insulated.
6. Piping insulating between heating source and indirect hot water tank.
X❑ '§150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and
Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed in conditioned space. Openings shall be sealed
with mastic, tape aerosol sealant or other duct- closure system that meets the applicable requirements of UL181, UL181A, or
UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh tape or
tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and
their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with
mastic and drawbands.
2. Exhaust fans systems have back draft or automatic dampers.
3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers.
§114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no electric resistance heating, no pilot.
2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas.
3. Pool system has directional inlets and a circulation pump time switch.
X] §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot
light. (Exception: Nonelectrical cooking appliances with pilot < 150 Btu/hr)
Lighting Measures
§150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general
lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an
entrance to the kitchen.
150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt
or greater switched at the entrance to the roam or one of the alternative to this requirement allowed in Section 150(k)2.; and
recessed ceiling fixtures are IC (insulation cover) approved.
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:5 of 10
Comauter Method Summary (Part 1 of 3) C -2R
Qalifornila Desert Construction 7/3/0'
Project Title Date
.92940 Avenida Nayarm I a Qinta
Project Address Building Permit #
Insii-Form Inc_ (760) 324-0216 Plan Check/Date
Documentation Author Telephone
Comauter Performance 15 I Field Check/Date
Source Energy Use
Standard
Proposed
Compliance
(kBtulsf-yr)
Design
Design
Margin
Space Heating
2.55
2.30
0.24
Space Cooling
36.96
39.07
-2.11
Domestic Hot Water
15.57
13.49
2.08
Totals
55.07
54.86
0.21
GENERAL INFORMATION
Conditioned Floor Area:
Building Type:
Building Front Orientation:
Number of Dwelling Units:
Number of Stories:
1,527
Single Fam Detached
(West) 270 deg
1.00
1
Floor Construction Type: Slab Floor
Raised Floor
Total Conditioned Volume: 15,270
Slab Floor Area: 1,527
BUILDING ZONE INFORMATION # of
Zone Name Floor Area Volume Units
Thermostat Vent
Zone Type Type Hgt. Area
rnnrtitinnPH SPthark n/H
Solar
OPAQUE SURFACES Act. Gains
Tvoe Area U -Val. Azm. Tilt Y / N Form 3 Reference Location / Comments
Computer Method Summary (Part 2 of 3) C -2R
California Desert Construction 7/3/03
Project Title Date
FENESTRATION SURFACES
# Type
Area
U-
Factor
SHGC
Act.
Azm.
Glazing Type
Tilt
Location/
Comments
J--
Windnw
Front
(West)
X4.0_
0.870
n.70
270
q0 nniihlP Mtl Unrnnted nPfault
I iving
lone
2
Window
Left
(North)
4.0
0.870
0.70
0
90 Double Mtl Uncoated Default
Living
Zone
3
Window
Left
(North)
16.0
0.870
0.70
0
90 Double Mtl Uncoated Default
Living
Zone
4
Window
Rear
(East)
20.0
0.870
0.70
90
90 Double Mtl Uncoated Default
Living
Zone
5
Window
Rear
(East)
7.0
0.500
0.65
90
90 Glass Block
Living
Zone
6
Window
Rear
(East)
16.0
0.870
0.70
90
90 Double Mtl Uncoated Default
Living
Zone
L
Window
Right
(South)
16.0
0,870
0.70
180
90 nnuble Mtl Uncoated Default
living
Zone
8
Window
Riqht
(South)
12.0
0.870
0.70
180
90 Double Mtl Uncoated Default
Living
Zone
6
Window Right (South)
4.0
umutu
umtu
iasu
Ott �ouoie
iwn uncoaie� uciaw�wu y woo
INTERIOR AND EXTERIOR SHADING
Left Fin Right Fin
Overhang
Window
#
Exterior Shade Type
SHGC
Hgt.
Wd.
Len.
Hgt. LExt.
REA Dist. Len. Hgt. Dist. Len. Hgt.
1
Bug Screen
0.76
4.0
6.0
2.0
0.1 2.0
2.0
2
Bug Screen
0.76
2.0
2.0
2.0
0.1 2.0
2.0
3
Bug Screen
0.76
4.0
4.0
2.0
0.1 2.0
2.0
4
Bug Screen
0.76
4.0
5.0
2.0
0.1 2.0
2.0
5
Bug Screen
0.76
3.5
0.8
12.0
0.1 12.0
12.0
6
Bug Screen
0.76
4.0
4.0
2.0
_ . 2.0
2.0
7
Bug Screen
0.76
4.0
4.0
2.0
0.1 2.0
2.0
8
Bug Screen
0.76
3.0
4.0
2.0
0.1 2.0
2.0
9
Bug Screen
0.76
2.0
2.0
2.0
0.1 2.0
2.0
Run Initiation Time 07/03103 11 24 08 Run Codes 1057227848
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number. Page:7 of 10
Computer Method Summary
(Part 3 of 3) C -2R
California Desert Construction
7/3/03
Project Title
Date
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat
Inside Location
Type (sf) (in.) Cap.
Cond. Form 3 Reference
R -Val Comments
PERIMETER LOSSES
F2 Insulation
Type Length Factor R -Val.
Depth Location / Comments
Slab Perimeter 800_76 0.0
0 Living Zone
Slab Perimeter 45 0.76 0.0
0 Living Zone
HVAC SYSTEMS
Heating Equipment* Minimum Distribution Type
Type (furnace, heat Efficiency and Location Duct Thermostat Location /
pump, etc.) (AFUE/HSPFXducts/attic, etc.) R -Value Type Comments
Central Furnace 80%AFUE Ducts in Attic 4.2 Setback Living Zone
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
Cooling Equipment Minimum Duct . 4
Type (air conditioner, Efficiency ' Location Duct Thermostat Location /
heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments
,Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Living Zone
WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1° Tank Insul.
Water Heater Water Heater Distribution. # in Input Cap. or Recovery Standby R -Value
System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) • Ext.
A.O. SMITH FPS -50-224 Small Gas' Standard 1 43.000 50 0.60 n/a n/a
1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
Run Initiation Time: 07/03/03 11:24:08 Run Code: 1057227848
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:8 of 10
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME
California Desert Construction
DATE
7/3/03
SYSTEM NAME
FLOOR AREA
1,527
Living Zone
Sensible
T
Number of Systems
Heating System
Output per System
Total Output (Btuh)
Output (Btuh/sqft)
Cooling System
Output per System
Total Output (Btuh)
Total Output (Tons)
Total Output (Btuh/sgft)
Total Output (sgftrron)
Air System
CFM per System
Airflow (cfm)
Airflow (cfm/sgft)
Airflow (cf nrron)
Outside Air (%)
Outside Air (cfm/sgft)
Note: values above given at ARI conditions
JEATING SYSTEM PSYCHROMETRI
72,000
72,000
47.2
47,000
47,000
26.0 OF 69.2 OF 69.2 of
Outside Air
0 cfm
Supply Fan
1595 cfm
69.2 OF
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
389.9 1
HVAC E UIPMEN'
1,595
BDP CO. 563AN048-A 30,625 12,350 72,000
1,595
1.04
407.2
0.0 Total Adjusted System Output 30,625 12,350 72,000
(Adjusted for Peak Design Conditions)
0.00 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible Latent
CFM
Sensible
1,520
26,648
3,64
627
27,244
0
1,332
1,362
0
0
0
0
01
F o
0
0 0
1,332 1,362
29,312 3,64 29,968
111.30F
Heating Coil
�% Return Air Ducts 'I
Supply Air Ducts
110.5 OF
ROOMS
70.0 OF
I
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.0 / 77.4 OF 78.8 / 66.4 OF 78.8 / 66.4 OF 60.9 / 59.8 OF
0 Supply Air Ducts
Outside Air
0 cfm Supply Fan Cooling Coil 61.6 / 60.0 OF
1595 cfm 54.1% R.H. ROOMS
78.8166.4 OF 78.0 / 66.2 OF
3.1
User Number: 2655
Return Air Ducts
Job Number.
of 10
ROOM LOAD SUMMARY
PROJECT NAME
California Desert Construction
DATE
7/3/03
SYSTEM NAME
Living Zone
FLOOR AREA
1,527
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Living Zone
Living
1
1,520
26,648
3,641
1,520
26,648
3,641
627
27,244
PAGE TOTAL 1 1,520 26,648 3,641 627 27,244
TOTAL 1 1,520 26,648 3,641 627 277244
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:10 of 10
O
O
z
W
v
O
CL
J
N
z
F-
z
CL
c
z
m
c