Loading...
SFD (0309-012)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date Signature of Contractor % �d i /.✓ fa ._ OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). () I am exempt under Section B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm tinder'penalty of perjury one ofjthe following declarations- ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for,. by Section 3700 of. the Labor Code, for the performance of the work for which this permit is issued. . . ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier Policy No. 0 TAT cF13N1) 134230.9 (This section need not be completed if the permit valuation is for $100.00 or less): () I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor ode, I shall forthwith comply with those provisions'�� ate: f,' .. a Applicant % Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages, as provided for in Section 3706 of the Labor Code, interest and attorney's fees. , IMPORTANT Application is hereby made to the Director of Building and -Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit. issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply,with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property for inspection purposes . /Signature (Owner/Agent)'~ ��!'r" f✓r,�'� Date PERMIT# -:._w PERMIT !�`�-BUILDING DATE - VALUATION LOT ; �};rf) .� TRACT JOB SITE - APN ADDRESS 57,340 MT01M OWNER CONTRACTOR/DESIGNER/FN INFER J,>:T9V JJ.J' .3 J+n�W s: '•'. ' - �'S7Y�r 1±dAkV...,S6.5'n CiVi:(+ud'+��h.raA�iV.'.A. c+�.m�a� il NaM.Dr.. FR'.F. p CA, A, 9 t P 604 PALM D S"31KRT CA 5+2264:; USE OF PERMIT i I �? ."i,Je St (Y dyLRivf"# ;7tJN.S Ih 1 �l fF.°%IT:;YSi: BLOCK 'KiiALLy PGOU SPA, 4.tai.`r.l�iar'���%A?+���IR�.ivANCH � �tA2.A�T�C�Cc�?t.34e'i' •A?0,�E1 �".�':� }?E°'LRMT17.1e r"'�MM.i�"Y' CONSTRUCTIaN PER, 10, 1 LI -00 �4 1$- 000 "r'R..M4 CHWX PIZ Zvi) 18N13CHANICA'.1, F42 1� i1Fi5'fTN:1Fit 30-0000-li 9 -000 $133,00 STi1 ti•tc:< A+tg)'9:C)1`I FER RtSID 103-0130 41.000D91.1(11 � tt �:.Ui�e 14 o}?1 l t3'i ^ 4� • 2 C+�tt3 I N•. fig 7KVJ:LQP'j 'R, tWACT FU -ms �y1:j0.flli y . IA1 P11 !t3T°2a, "' RRIJC3=1:tW ARD PLA11 C11T.:c {•It j� Irk D03 PP. Pflulo :i` ' ,.°O ',a9,zp.2. a t�4n.1'J U, S�Q 10.2003.. xAL:f? $M'i;1°:37a 6 D$-° No fE�!AC DEFT.. , RECEIPT DATE BY DATE FINALED"' SPECTO INSPECTION RECORD OPERATION DATE INSPECTOR BUILDING APPROVALS Set Backs —/ - O Forms & Footings Waste Lines _ O Slab Grade iGl a Steel d p Roof Deck Bond Beam O.K. to Wrap Sewer Lateral Framing a'l z2' Insulation G Fireplace P.L. Fireplace T.O. Party Wail Insulation Party Wall Firewall Exterior Lath Drvwall - Int. Lath OPERATION DATE INSPECTOR MECHANICAL APPROVALS Underground Ducts Ducts Return Air Combustion Air Exhaust Fans F.A.U. Compressor Vents Grills Fans & Controls Appliances Final COMMENTS: Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power G7_ A1__ A Q11-11 "7 Final Utility Notice Final Final Underground Plbg. Test Final POOLS - SPAS BLOCKWALL APPROVALS Gas Test Electric Final Waste Lines _ O Steel Set Backs Electric Bond Footings I Main Drain Bond Beam I Aenroval to Covor Appliances Final COMMENTS: Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power G7_ A1__ A Q11-11 "7 Final Utility Notice Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines _ O Heater Final 'Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection I Encapsulation Gas Pivina Appliances Final COMMENTS: Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power G7_ A1__ A Q11-11 "7 Final Utility Notice 0304-01Z 4 44 P.O. BOX 1504 APPLICATION ONLY Building 78-495 CALLE TAMPICO Address LA QUINTA, CALIFORNIA 92253 Owner Mailing BUILDING: TYPE'CONST. OCC. GRP. Address s%. A.P. Number 3' r3 — 5-0-5- •oDiL Zip l Tel. Q d -(Ayr— p� v 2 Z a 3 g- Legal Description ��. a[.1� 1"0 C� S Contractor _ I 5 F -T � Project Description Address �r Q .Al tyZip Tel.. �O l.'m i 2 1 6Q -:b- fy State Lic. l City & Classif.,g 6a S Q Lic. # 00 Sq. Ft. 7 No. No. Dw. Arch., Engr., Size ��� Stories Units Designer New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Address Tel. City Zip State Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licens d under Drovisions of Chapter 9 (commencing with Section 7000) of Divisi 3 of t us' fs Professions Code, and my license is in full f rce and ' effect. �7 �VC -D i SIGNATURE' a DATE OWNER -BUILDER DECLARATION Estimated Valuation I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, Improve, demolish, or repair any structure, prior to 'its Issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to PERMIT AMOUNT the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code. or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit Plan Chk. Dep. so - 00 subjects the applicant to a civil penalty of not more than five hundred dollars ($500). I.: I, as owner of the property, or my employees with wages as their sole compensation, will Plan Chk. Bal. do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Const. Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees. Mech. provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden Electrical of proving that he did not build or improve for the purpose of sale.) I'I I, as owner of the property, am exclusively contracting with licensed contractors to con- Plumbing struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for S,M,I- such projects with a contractors) licensed pursuant to the Contractor's License Law.) 1 nil I'7 I am exempt under Sec. B. & P.C. for this reason Grading Driveway Enc. Date Owner InfrastnictUre WORKERS' COMPENSATION DECLARATION LU I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Co pe aif Ins rance, or a ce 'fi co thereof. (Se .3800, Labor C'(q�]e.l FINANCE Policy No���CompanyL�— fl Copy is filed with the city. ❑ Certified copy is hereby furnished. TOTAL CERTIFICATE OF EXEMPTION FROM REMARKS WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become ZONE: BY: subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line CONSTRUCTION LENDING AGENCY Side Street Setback from Center Line by affirm that there is a construction lending agency for the performance of the work for this permit is issued. (Sec. 3097, Civil Code.) Side Setback from Property Line Lender's Name Lender's Address FINAL DATE INSPECTOR This is a building permit properly filled out, signed and validated, and is subject to expiration if work thereunder is s dad for 180 days. I certify that I have read this applica nd state that the above information is correct. Issued by: Date Permit I agree to comply with all city and county ances and state laws relating to building construction, and hereby authorize represents sof this city to enter the above• mentioned property for inspection purposes. Validated by: Signature of applicant ate Mailing Address Validation: City, State, Zip WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE CERTIFICATE OF COMPLIANCE JFs(0, Desert Sands Unified School District �4'?) 47950 Dune Palmi Road q ¢BERMUDA DUNES 7 r Date 9/10/03 La QUinta CA 92253 rn RANCHO MIRAGE d {I INDIAN WELLS �. No. 24940 (760) 771-8515 �,� PALM QUIN y �INDIO JJ Owner David Peters APN # 773-305-002 , Address 73-170 Amber St. Jurisdiction La Quinta City Palm Desert Zip 92260 Permit # 0309-012 Tract # BLK140 Study Area Type Single Family Residence No. of Units 1 - Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 22 52540 Avenida Navarro 1527 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garageskarports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.14 X 1,527 S.F. or $3,267.78 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By C/C Untion Bank of California -David Peters Check No. 8371112 Name on the check Telephone 340-9844 Funding Residential By Dr. Doris Wilson Superintendent Fee collected /exemp ed by Patricia Barbuzza Signature rJ1_1 ' ' Payment Recd 1$0.00 $3,267.78 y Over/Under NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting RECORDING RE(ftSTED BY: COMMONWEALTH LAND TITLE COMPANY 12627JE WHEN RECORDED MAIL THIS DEED AND, UNLESS OTHERWISE SHOWN BELOW, MAIL TAR STATEMENTS TO: David A. Peters Veronica M. Peters 73170 Amber Street Palm Desert, CA 92260 M S U PAGE WE DA PCOR NOCOR SMF "ASC. A R U COPY LONG _ REFUND , NC.4G i EWA APN: GRANT T DIEED 773-305-002-3 oaa - 0 / 7 The undersigned grantor(s) declare(s): Documentary transfer tax is $71.50 ?;XX Computed on full value of property conveyed, or Computed on full value less liens and encumbrances remaining at time ofsale. Unincorporated area: ( ) City of and FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, _.. Gabrie.l -Vi 1:lagomez and Elizabel..G_. Villagomez , husband and --wife as Joint .... tenants. hereby GRANT(S) to David A. Peters,and Veronica M. Peters, husband and wife as -joint tenants the real property in the City of La Quinta, County of Riverside, State of California, described as: Lot 22, Block 140, Santa'Carmelita at Vale La Quinta, Unit 15, as per map recorded in Book 18, Page 92 of Maps - SEE "EXHIBIT A" ATTACHED HERETO Dated March 7, 2003 State of California' Count of JVG1 S/�� } S.S. On 9. l T � before me, fgwe,+_7- N l� OfQN r h�t4 personally appeared ..personally kfnown to me (or proved to me on the basis of satisfactory,evidence) to be whose name) "/are subscribed the person to the within instrument and acknowledged to me that ha/_�/they executed the same in bjg/Jiex-/their authorized capacity , and that by hide-their, he itmature 0 o the instrument the person o ,o the entity upon behalf of which the person& acted, executed the instrument. WITNESS my ha and icial seal. Signature (This area for official notarial seal) MAIL, TAX STATEMENTS iM 111111 illlii lilil 1111 Illlil II�i Illiili Ili lilll lifillll �4 �g y 2 of3���� .Gabriel Villagoluef, Eliz el. G_. VillagoMe76 i R PAMELAJ. HOTT11Q. , Commission # 1310266 Notary Public - California Riverside Ca=t fly con-, a0res r A TITLE 24 REPORT Title 24 Report for: California Desert Construction 52540 Avenida Navarro La Quinta, CA ; Project Designer: Report Prepared. By: Joan D. Hacker Insu-Form Inc. 68255 Corta Road ' Cathedral City, CA 92234 (760) 324-0216 CITY OF LA OUINTA BUILDING & SAFM DEM APPROVED FOR CONSTRUCTION. DATE Job Number: oV'F14(5r Date: 7/3/03 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 . By EnergySoft Job Number: User Number. 2655. ' TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2R Computer Method Summary HVAC System Heating and Cooling Loads Summary Room Load Summary Certificate of Comoliance: Residential (Part 1 of 2) CF -1R California Desert Construction 7/3/03. Project Title Date 52540 Avenida Navarro La Quinta Project Address Building Permit # Insu-Form Inc. (760) 324-0216 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 1,527f? Average Ceiling Height: 10:0 ft Total Conditioned Slab Area: 1,527 ft2 Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (West) 270 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component Type Frame Type Const. Assembly U -Value Slab On Grade n/a 0.756 Slab On Grade n/a 0.756 R-13 Wall w/1" EPS Wood 0.059 Solid Wood Door None 0.387 R-38 Roof (R.38.2x14.16) Wood 0.028 FENESTRATION Location/Comments (attic, garage, typical, etc.) Covered Slab w/R-0.0 Perimeter Insulation Exposed Slab w/R-0.0 Perimeter Insulation Exterior Wall Exterior Door Exterior Roof Shading Devices Type Orientation Area Fenestration Exterior . Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Front (West) 24.0 0.87 0.70 Bug Screen x❑ ❑ ❑ x❑ Left (North) 20.0 0.87 0.70 Buq Screen x❑ ❑ ❑X❑ Rear (East) 36.0 0.87 0.70 Bug Screen x❑ E] 1:1 RX (East) 7.0 0.50 0.65 Buq Screen x❑ ❑ ❑ x❑ Right (South) 32.0 0.87 0.70 Buq Screen X❑ ❑ ❑ X❑ El 1:1 ❑❑ El El ❑ ❑ El El El F-1 1:1 1:1 1-1 F1 El F] El F-1 El El El El El El El Run Initiation Time: 07/03/03 11:24:08 Run Code: 1057227848 EnergyPro 3.1 By Ener oft User Number: 2655 Job Number: Pa e:3 of 10 'Certificate of Compliance: Residential (Part 2 of 2) CF -1 R California Desert Construction 7/3/03 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Equipment Minimum Distribution HeatingType and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Cantml Fijrna(,a 80% AFUE Ducts in Attic 4.2 Setback Living Zone Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type - Comments Split Air Conditioner 12.0 SEER Ducts in Attic 42 Sethack Living 7nnp WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A.O. SMITH FPS -50-224 Small Gas Standard 1 43.000 _50 0.60 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section. Designer or Owner (per Business & Prof ions Code) Documentation Author 1V� Name: � �7,49. Name: Joan D. Hacker Title/Firm: Title/Firm: Insu-Form Inc. Address: Address: 68255 Corta Road Cathedral City, CA 92234 Telephone: 7 - Telephone: (760) 324-0216 Enforcement Agency Name: Title/Firm: Address: Telephone: (signature/stamp) (date) Run Initiation Time: 07/03/03 11:24:08 Run Code: 1057227848 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:4 of 10 Mandatory Measures Checklist: Residential MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A If not applicable. DESIGNER ENFORCEWIEN Building Envelope Measures F'§150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value. .§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). ❑ '§150(d): Minimum R-13 raised floor insulation in framed floors. § 150(1): Slab edge insulation - water absorption rate <= 0.3%, water vapor transmission rate <= 2.0 perm/inch. ❑X §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. FXJ §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified SHGC, and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ® §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue damper and control; 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures X] §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i): Setback thermostat on all applicable heating and/or cooling systems. §1500): Pipe and Tank Insulation Al 1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. X❑ '§150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed in conditioned space. Openings shall be sealed with mastic, tape aerosol sealant or other duct- closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh tape or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fans systems have back draft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no electric resistance heating, no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. 3. Pool system has directional inlets and a circulation pump time switch. X] §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Nonelectrical cooking appliances with pilot < 150 Btu/hr) Lighting Measures §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the roam or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:5 of 10 Comauter Method Summary (Part 1 of 3) C -2R Qalifornila Desert Construction 7/3/0' Project Title Date .92940 Avenida Nayarm I a Qinta Project Address Building Permit # Insii-Form Inc_ (760) 324-0216 Plan Check/Date Documentation Author Telephone Comauter Performance 15 I Field Check/Date Source Energy Use Standard Proposed Compliance (kBtulsf-yr) Design Design Margin Space Heating 2.55 2.30 0.24 Space Cooling 36.96 39.07 -2.11 Domestic Hot Water 15.57 13.49 2.08 Totals 55.07 54.86 0.21 GENERAL INFORMATION Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: 1,527 Single Fam Detached (West) 270 deg 1.00 1 Floor Construction Type: Slab Floor Raised Floor Total Conditioned Volume: 15,270 Slab Floor Area: 1,527 BUILDING ZONE INFORMATION # of Zone Name Floor Area Volume Units Thermostat Vent Zone Type Type Hgt. Area rnnrtitinnPH SPthark n/H Solar OPAQUE SURFACES Act. Gains Tvoe Area U -Val. Azm. Tilt Y / N Form 3 Reference Location / Comments Computer Method Summary (Part 2 of 3) C -2R California Desert Construction 7/3/03 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments J-- Windnw Front (West) X4.0_ 0.870 n.70 270 q0 nniihlP Mtl Unrnnted nPfault I iving lone 2 Window Left (North) 4.0 0.870 0.70 0 90 Double Mtl Uncoated Default Living Zone 3 Window Left (North) 16.0 0.870 0.70 0 90 Double Mtl Uncoated Default Living Zone 4 Window Rear (East) 20.0 0.870 0.70 90 90 Double Mtl Uncoated Default Living Zone 5 Window Rear (East) 7.0 0.500 0.65 90 90 Glass Block Living Zone 6 Window Rear (East) 16.0 0.870 0.70 90 90 Double Mtl Uncoated Default Living Zone L Window Right (South) 16.0 0,870 0.70 180 90 nnuble Mtl Uncoated Default living Zone 8 Window Riqht (South) 12.0 0.870 0.70 180 90 Double Mtl Uncoated Default Living Zone 6 Window Right (South) 4.0 umutu umtu iasu Ott �ouoie iwn uncoaie� uciaw�wu y woo INTERIOR AND EXTERIOR SHADING Left Fin Right Fin Overhang Window # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 4.0 6.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 3.5 0.8 12.0 0.1 12.0 12.0 6 Bug Screen 0.76 4.0 4.0 2.0 _ . 2.0 2.0 7 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 3.0 4.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 Run Initiation Time 07/03103 11 24 08 Run Codes 1057227848 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number. Page:7 of 10 Computer Method Summary (Part 3 of 3) C -2R California Desert Construction 7/3/03 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 800_76 0.0 0 Living Zone Slab Perimeter 45 0.76 0.0 0 Living Zone HVAC SYSTEMS Heating Equipment* Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPFXducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Setback Living Zone Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct . 4 Type (air conditioner, Efficiency ' Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments ,Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Living Zone WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1° Tank Insul. Water Heater Water Heater Distribution. # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) • Ext. A.O. SMITH FPS -50-224 Small Gas' Standard 1 43.000 50 0.60 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 07/03/03 11:24:08 Run Code: 1057227848 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:8 of 10 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME California Desert Construction DATE 7/3/03 SYSTEM NAME FLOOR AREA 1,527 Living Zone Sensible T Number of Systems Heating System Output per System Total Output (Btuh) Output (Btuh/sqft) Cooling System Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sgft) Total Output (sgftrron) Air System CFM per System Airflow (cfm) Airflow (cfm/sgft) Airflow (cf nrron) Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions JEATING SYSTEM PSYCHROMETRI 72,000 72,000 47.2 47,000 47,000 26.0 OF 69.2 OF 69.2 of Outside Air 0 cfm Supply Fan 1595 cfm 69.2 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 389.9 1 HVAC E UIPMEN' 1,595 BDP CO. 563AN048-A 30,625 12,350 72,000 1,595 1.04 407.2 0.0 Total Adjusted System Output 30,625 12,350 72,000 (Adjusted for Peak Design Conditions) 0.00 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 1,520 26,648 3,64 627 27,244 0 1,332 1,362 0 0 0 0 01 F o 0 0 0 1,332 1,362 29,312 3,64 29,968 111.30F Heating Coil �% Return Air Ducts 'I Supply Air Ducts 110.5 OF ROOMS 70.0 OF I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.4 OF 78.8 / 66.4 OF 78.8 / 66.4 OF 60.9 / 59.8 OF 0 Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 61.6 / 60.0 OF 1595 cfm 54.1% R.H. ROOMS 78.8166.4 OF 78.0 / 66.2 OF 3.1 User Number: 2655 Return Air Ducts Job Number. of 10 ROOM LOAD SUMMARY PROJECT NAME California Desert Construction DATE 7/3/03 SYSTEM NAME Living Zone FLOOR AREA 1,527 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Living Zone Living 1 1,520 26,648 3,641 1,520 26,648 3,641 627 27,244 PAGE TOTAL 1 1,520 26,648 3,641 627 27,244 TOTAL 1 1,520 26,648 3,641 627 277244 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:10 of 10 O O z W v O CL J N z F- z CL c z m c