Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
SFD (0307-044)
f LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of t H Chapter 9 (commencing with Section 7000) of Division 3 of the Business and 04 LU Professionals Code, and my License is in full force and effect. O =) M License # Lic. Class Exp. Date LU 626404 B 1 JI r: /07 oZ r-- JDate � 1 ' 93 Signature of Contractor_' � .. CCD 9. ��,.. �� I.— 6p OWNER -BUILDER DECLARATION -Y W a r I hereby affirm under penalty of perjury that I am exempt from the Contractor's I) License Law for the following reason: Z_ ( ) I, as owner of the property, or my employees with wages as their sole. compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business.& Professionals Code).. ( ) I, as owner of the property, am exclusively contracting with, licensed contractors to construct the project (Sec., 7044, Business & Professionals Code). MO I am exempt under Section B&P.C' for this reason N Date Signature of Owner O d Q WORKER'S COMPENSATION DECLARATION 'gyp Z I hereby affirm under penalty of perjury one of the following declarations: 7f"r H O O 1 have and will maintain a certificate of consent to self -insure for workers' X .0 l LL compensation; as provided for by Section 3700 ,of the- Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section=3700 of the Labor Code, for the performance of the work for'which this rd, Z permit is issued. My workerscompensation insurance carrier & policy no. are: oo Carrier Policy No. S'J TATE Fi12�1% 132304-0a 0 :. I Q (This,section need not be completed if the permit valuation is for. $100.00'6r less). ( ).,,1 certify that in the performance of the work for which this permit is issued, i! I shall not employ any person in any manner so as to become subject to the .i� workers' compensation, laws of California, and agree that if Ishould become subject to the workers' compensation provisions of Section 3700 of the Labor Code, -f shall forthwith comply with those provisions. r1'J. ,Date: Applicant- ' Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in. addition to the cost of -compensation, damages'as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to �\ any permit issued as a result of this applicaton agrees to, & shall, indemnify., �^Vip & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is • correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon °C the above-mentioned property for inspection purposes. •Signature (Owner/Agent)' Date zi` +PERMIT# -]BUILDING -PERMIT D. ° 'VALU_ATI ATEON LOT TRACT 20 HLIC 140 •; JOB SITEAPN ADDRESS 524440 ! A. f�. NSDA. SAVARP10 OWNER CONTRACTOR / DESIGNER / ENGINEER �� ��(T��// ,,.,''{{ r7��t 7� �q /� �y..y � �y�}•� ( COMIC PM x1l:,E:e ,.lYld..[`7. P -W dba 4•�-91JM.3,�.I XC�db'�.�5 , '(�y��''p� /�j�y,''� �j •y� ��j� � yy 9 /���q;Yy:�'rp� /�f m��y J:"J.�ivL' IV.[A.i'16. A'l..S'.. 537:➢a �.%a".l. DEM.r COMST T3«170AMSM:STIt- 7,r . : 7:3-1?0,AYvil„ ZMM�I' PAy.,MllMERZ CA . 42260 , 'P.ALM DiMT Cali 92260 %(7' 0)-�4101-9844 (MIR, 4.801 USE OF PERMIT, �I.1a'f1L�'. T:+Al�I:L,� 7,�"�/�,1:,3xdf�• 4 15r, S.Ip SFD -PPL .MIT DOES NOT INC14108 DWCK WALL P0011 dSP;A.' ' ORI1A.Iip'MAY:A'POACH . TRACT CP3NS iu1.IC'1 TIOW 1Y5",00 VF PC1RMPA110" 165AD' SP OARAWCARP0ftl' 470J10 3F RNITLWAMED COW 0,F CC+.lV'S2'RUCTIOBT Cams'lfRu "i'.lom i um 101.000.41 6-0b0 X61%Q0 PLAN Cf3YC:fr?; IE1; 1Q1'-000-4_4-318 VEE MPOS,'°t` f .. 101.000-439-318 42".00 A/ECHAldICALI?`P.Z 1101••On-0.421-000 420.000 ELECTRICAL FEE: 191-,-000,420-000 PI. UM21MG, FEE 101-00 0-419.400 1➢ 8,00 STRONG MOTION F.ETs - R1 SID . '1()1-000,.241.000 $9,43 GRA iIIdO PE 9'� F=OUfl-X1 3-Qi31� $15.00 DL*1 eLoPm Iiv9PJkff FEE V,405;00 PReCISS PLAN 1.611-000-441-34 . y SlbB,,7f }7 r`' ° L`i?�TC 1�C1A3'.R3� t5' PLAAa C��C� $3,948.02 MND PRE-PAm Mi 34 4250,00 ' 1 ' .P.`KKW1 g?`k.DUE X901 AUG 12.2003 ' CITY OF d!\ QUiNTA PImocE DEPT. . RECEIPT DATE BY DATE FINALED INSPECTOR INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs p Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans O.K. to Wrap F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final BLOCKWALL APPROVALS POOLS - SPAS Steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final I I Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole oe Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: �o�•oyy Building4 ^ pQ Address _ L li 4 4 " P.O. BOE 1504APPLICATION ONLY p ems, 78 495 CALLE TAMPICO tAtIAIRIQa LA QUINTA, CALIFORNIA 92253 IPJ 9 11%An?'AJ;11 I&AI i k � VIP' //lG . I Mailing ) Address 14 ZityIzipf 2 Z / VVD• / 2 Z6/D I Telma JPO State Ljc./ ^ �D City & Classif. 6 oV Lic. # Arch., Engr., Designer Address CityI Zip State Lic. # LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm that I am Iicens rovisions of Chapter 9 (commencing with Section 7000) of D f ih u ' P Ions Code, and my license is in full force and effect. SG R DATE OWNER -BUILDER DECLARATION I hereby affirm that 1 am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, Prior to -its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). I; I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or of, for sale. (Sec. 7044, Busness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) 1.1 I, as owner of the property, am exclusively contracting with licensed contractors to con. struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License taw does not apply to an owner of property who builds or improves thereon, and who contracts for Such projects with a contractor(s) licensed pursuant to the Contractor's License Lew.) l I am exempt under Sec. B. & P.C. ;=n r on Dat nw WORKERS' COMPENSATION DECLARATION I hereby affirm that 1 have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company rl Copy is filed with the city. 0 Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, alter making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address _. This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above- mentioned property for inspection purposes. Signature of Mailing Add City, State, LDING: TYPE'CONST. VN OCC. GRP. R • 3 Number 213 • 30 S. 00A al Description W Lex 2v B L -V_ IH D t )-is ect Description Sg' n Sq. Ft. I � .,/ No. Size iq Stories Stories Unitss New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ PERMIT AMOUNT Plan Chk. Dep.'s Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setba c1f 1MIG ester Line FINAL DATE Issued by: Validated by: Validation: WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE /I Date 8/12/03 No. 24803 CERTIFICATE OF COMPLIANCEt VIED, Desert Sands Unified School District T > {q� %#o 47950 Dune Palms Road - ¢BERMUDA DUNES La Quinta CA 92253 14 COO RANCHOMIRAGE f �+ INDIAN WELLS 771-8515 PALM DESERT 1760` { l �i}% LA QUINTA INDIO Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.14 X 1,527 ' S.F. or $3,267.78 have been paid for the property listed above and that - building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Union Bank of California - David Peters Check No. 8370966 Name on the check Telephone 760/340.9844 Funding Residential By Dr. Doris Wilson t Superintendent Fee collected /exempted aron McGilvrey Payment Recd $3,267.78 Over/Under Signature C NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting Q Q y? . Owner Pine Mountain Real Estate APN # 773-305-004 Address 73170 Amber Street Jurisdiction La Quinta City Palm Desert Zip 92260 Permit # 0307-044 Tract # BLK 140 Study Area Type Single Family Residence No. of Units 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 20 52580 Avenida Navarro 1527 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.14 X 1,527 ' S.F. or $3,267.78 have been paid for the property listed above and that - building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Union Bank of California - David Peters Check No. 8370966 Name on the check Telephone 760/340.9844 Funding Residential By Dr. Doris Wilson t Superintendent Fee collected /exempted aron McGilvrey Payment Recd $3,267.78 Over/Under Signature C NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting RE60RDING RE F T OBD RE�.r� ThE GO. AND WHEN RECORDED, MAIL TO: California Desert Construction 73-170 Amber St. Palm Desert, CA 92260 ASSESSOR'S PARCEL NO.: 773-305-004/005 -AA 0SO-0/--P- .TITLE; ORDER NO.: 500705-13 ESCROW NO.: 5706 -DS GRANT ®EE® f oc*vo,n 2000-072532 02/29/2000 06:00A Fee:26.00 Page i of 1 Dae T Tax Paid Recorded in official Records County of Riverside Gary L. Orso Assessor, County Clerk d Recorder M $ U PAGE SIZE DA PCOR NOCCR SMF NOSC, A R L COPY � LONG REFUND NCH�i EXAM C2-fo The undersigned Grantor(s) declare that the DOCUMENT T [NN9rRTAX IS: $ /7.0o County $ City . Ax computed on the_ full value of the - interest of property. convey , or. . _computed on the full value less the value of liens or encumbrances remaining. thereon at the time of. sale. OR transfer is EXEMPT from tax for the following reason: FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Paul S. Berger and Jamie Berger, Trustees of The Berger Family Trust UWD1 July 1, '1957 as to an undivided one-half Interest and E. Steven Solton, a married man as his sole and separate property, as to an undivided one-half interest. hereby GRANT(S) to Pine Mountain Real Estate, Inc. all that real property situated in the City of La Quinta County of Riverside, State of California, described as: Lot: 20 in Block 140 of Santa Carmelita, Unit 15 as per map recorded in Book 18, page 92 of maps, Records of Riverside County, California. Dated January 31, 2000 STATE OF CA IFORN A, COUNTY OF �,p5 ON a 4Pq 9 &M, before me ���/ 7�Nit� Notary Public, personally appeared / S�-n,A personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within Instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS my hand and official seal. Signature �-a-a Pewl S. Berger, Truste �t&v_a - 9� J(onie Berger, Trustee (J E. Steven Solton KATHM t OINNEO Comrtrtssfon 0 1143336 ®► Notryy public — California Los Angeles County My Comm. Expires Jun 23, 2001 r MAIL TAX STATEMENTS TO: (This area for official notary seal) California Desert Construction - 73-170 Amber St., Palm Desert, CA 92260 a YA ' TITLE 24 REPORT Title 24 Report for: California -Desert Construction C2580_A ev nida Navarr�. La Quina CA Project Designer: 0 Report Prepared By: Joan D. Hacker Insu-Form Inc. 68255 Corta Road Cathedral City, CA 92234, 12:1 (760) 324-0216, • LD st tie h Job Number: CITY OF LA QUANTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION Date:� DAA 0 3 B*Zjk� 3/13/03 0 -0- 307 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number. User Number: 2655 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Checklist 5 Form C -2R Computer Method Summary 6 HVAC System Heating and Cooling Loads Summary 9 Room Load Summary 10 EnergyPro 3.1 By EnergySoft Job Number: User Number. 2655 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R California Desert Construction R-13 Wall w/1" EPS 3/13/03 Project Title None Date 52580 Avenida Navarro La Quinta U -Factor SHGC Shading Project Address Yes / No Front Building Permit # Insu-Form Inc. (760) 324-0216 0.70 Bug Screen Documentation Author Telephone Left Plan Check / Date Computer Performance 15 0.70 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 1,527 ft2 Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 1,527 ft2 Building Type: (check one or more) © Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (West) 270 dem Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component Tvoe Const. Frame Assembly Location/Comments Type U -Value (attic, garage, typical, etc.) Slab On Grade n/a Slab On Grade n/a R-13 Wall w/1" EPS Wood Solid Wood Door None R-38 Roof (R.38.2x14.16) Wood FENESTRATION 0.756 Covered Slab w/R-0.0 Perimeter Insulation 0.756 Exposed Slab w/R-0.0 Perimeter Insulation 0.059 Exterior Wall 0.387 Exterior Door 0.028 Exterior Roof U -Factor SHGC Shading Yes / No Yes / No Front (West) 24.0 Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Front (West) 24.0 0.87 0.70 Bug Screen X❑ ❑ ❑ x❑ Left (North) 20.0 0.87 0.70 Bug Screen C ❑ ❑ a Rear (East) 36.0 0.87 0.70 Bug Screen a ❑ ❑ o Rear (East) 7.0 0.50 0.65 Bug Screen 011 E] 0Right (South) 32.0 0.87 0.70 Bug Screen a ❑ ❑ o ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ El El ❑❑ El El 11 El 1:1 1-1 El El El El F-1 D El El Run Initiation Time: 03/13/03 10:26:54 Run Code: 1047551214 EnergyPro 3.1 By Ener Soft User Number: 2655 Job Number: Page: 3 of 10 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R California Desert Construction 3/13/03 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments (:Pntral Fi imarp 80% AFUE Ducts in Attic 4.2 Setback Living Zone Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4 7 Setback Living 7nnp WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A.O. SMITH FPS -50-224 Small Gas Standard 1 43 000 s0 0.60 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS GUmrLIANUt_ J I A I tMtN 1 This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall desigyyresp n��slbility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feal'r thatjss ded is indicated in the Special Features/Remarks section. Designer�o, Owner per Business &t�Proffeession odle)�/�� Documentation Author Name. AX1110 X � ! ,-/V Name: Joan C. Hacker Title/Firm: Title/Firm: Insu-Form Inc. Address: Address: 68255 Corta Road r� Cathedral City, CA 92234 Telephone: V69Telephone: (760) 324-0216 Lic. #: (sig ature) (date) (sign ur) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature/stamp) (date) Run Initiation Tim • 03/13/03 10.26.54 Run Codes 1 047 551 21 4 EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number: PageA of 10 Mandatory Measures Checklist: Residential MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMEN Building Envelope Measures ❑X 1150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value. n .§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). -§ 15Q(d): Minimum R-13 raised floor insulation in framed floors. § 150(1): Slab edge insulation - water absorption rate <= 0.3%, water vapor transmission rate <= 2.0 perm/inch. ❑X §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified SHGC, and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ® §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue damper and control; 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ^§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. FX] §150(1): Setback thermostat on all applicable heating and/or cooling systems. §150Q): Pipe and Tank Insulation 1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemal/extemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. X❑ '§150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R4.2 or enclosed in conditioned space. Openings shall be sealed with mastic, tape aerosol sealant or other duct- closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh tape or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fans systems have back draft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. FX§114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no electric resistance heating, no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. 3. Pool system has directional inlets and a circulation pump time switch. X❑ §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) Lighting Measures §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/waft or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. L nergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Page:5 of 10 Computer Method Summary (Part 1 of 3) C -2R C.alifornia_[lesert ConStn it inn 3/13/03 Project Title Date 52580 Avenida Navarro La Quinta Project Address Building Permit # Insu-Form Inr._ (760) 324-0216 Documentation Author Telephone plan Check/Date Computer Performance Compliance Method (Package or Computer) 15 Climate Zone 1 Field Check/Date Source Energy Use Standard Proposed Compliance (kBtulsf-yr) Design Design Margin Space Heating 2.55 2.30 0.24 Space Cooling 36.96 39.07 -2.11 Domestic Hot Water 15.57 13.49 2.08 Totals 55.07 54.86 0.21 F777__ __ BUILDING COMPLIES GENERAL INFORMATION Conditioned Floor Area: 1,527 Floor Construction Type: XD Slab Floor Building Type: Single Fam Detached ❑ Raised Floor Building Front Orientation: (West) 270 deg Number of Dwelling Units: 1.00 Total Conditioned Volume: 15,270 Number of Stories: 1 Slab Floor Area: 1,527 BUILDING ZONE INFORMATION # of Zone Name Floor Area Volume Units I *vonq 7nne 1 527 1S 270 1 nn OPAQUE SURFACES Act. Type Area U -Val. Azm. Tilt Wall a6 0.059 270 90 nnnr 20 0.387 270 90 W,gll— 390 0.059 qf) Wall 357 0.059 go _90 Wall 328 0.059 180 go Roof 1 527 0n28 180 U Solar Gains ��� ■M 6 P. MIF Thermostat Vent Zone Type Type Hgt. Area rnnrl*t*nneri Cethank n/a Location / Comments living Zone I ivinFl Zone I iving Zone L*v*ng Zone living Zone I iv*ng 7nne L— EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number. Paae:6 of 10 1 Computer Method Summary (Part 2 of 3) C -2R California Desert Construction 3/13/03 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments _1_ Window Front es) 24.0 0.870 070 270 90 Douhle Mtl Uncoated nefault living Zone 2 Window Left (North) 4.0 0.870 0.70 0 90 Double Mtl Uncoated Default Living Zone 3 Window Left (North) 16.0 0.870 0.70 0 90 Double Mtl Uncoated Default Living Zone 4 Window Rear (East) 20.0 0.870 0.70 90 90 Double Mtl Uncoated Default Living Zone 5 Window Rear (East) 7.0 0.500 0.65 90 90 Glass Block Living Zone 6 Window Rear (East)_ 16.0 0.870 '0.70 90 90 Double Mtl Uncoated Default Living Zone L Window Right (South) 16.0 0.870 0.70 180 90 Double Mtl Uncoated Default Living Zone 8 Window Right (South) 12.0 0.870 0.70 180 90 Double Mtl Uncoated Default Living Zone J Window Right (South) 4.0 0.870 0.70 180 90 Double Mtl Uncoated Default Uvonci Zone INTERIOR AND EXTERIOR SHADING Window Overhanq Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 4.0 6.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 3.5 0.8 12.0 0.1 12.0 12.0 6 Bug Screen 0.76 4.0 4.0 2. 0. 2.0 2.0 7 Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 3.0 4.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 Run Initiation Time: 03/13/03 10:26:54 Run Code: 1 047 551 21 4 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number. Page:7 of 10 Computer Method Summary (Part 3 of 3) C -2R California Desert Construction 3/13/03 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 80 0.76 0.0 0 Living Zone Slab Perimeter 45. -.,76 0.0 0 Living Zone HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPFxducts/attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback Living Zone Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Living Zone WATER HEATING SYSTEMS Rated' Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A.O. SMITH FPS -50-224 Small Gas Standard 1 43.000 50 0.60 n/a n/a _ 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 03/13/03 10:26:54 Run Code: 1047551214 EnergyPro 3.1 By EneroySoft User Number: 2655 Job Number: Page:8 of 10 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE California Desert Construction 3/13/03 SYSTEM NAME FLOOR AREA Living Zone 1,527 NGINEERING CHECKS Number of Systems 1 Heating System Output per System 72,000 Total Output (Btuh) 72,000 Output (Btuh/sgft) 47.2 Cooling System Output per System 47,000 Total Output (Btuh) 47,000 Total Output (Tons) 3.9 Total Output (Btuh/sqft) 30.8 Total Output (sgft/Ton) 38g.g Air System CFM per System 1,595 Airflow (cfm) 1,595 Airflow (cfm/sgft) 1.04 Airflow (cfm/Ton) 407.2 Outside Air 0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS 26.0 of 69.2 of 69.2 of Outside Air 0 cfm 69.2 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 1,520 26,648 3,64 627 27,244 0 1,332 1,362 0 -0 0 0 0 0 0 0 0 1,332 1,362 29,312 3,64 29 96i BDP CO. 563AN048-A 30,625 12,350 72,000 Total Adjusted System Output 30,625 12,350 72,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am ream Temperatures at Time of Heatina Peak) 111.3 OF Supply Fan Heating Coil 1595 cfm h Return Air Ducts `s Supply Air Ducts 110.50F ROOMS 70.0 of DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.4 of 78.8 / 66.4 of 78.8 / 66.4 of 60.9 / 59.8 of Supply Air DuctS Outside Air &- I 0 cfm Supply Fan Cooling Coil 61.6 / 60.0 of 1595 cfm 54.1% R. H. ROOMS 78.8 / 66.4 of 78.0 / 66.2 of h Return Air Ducts `i I EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number. Paoe:9 of 10 1