12-0295 (SOL)
P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 12-00000295 Property Address: 78685 AVENIDA NARANJA APN: 770 -106 -003 - Application description: SOLAR Property Zoning: LOW. DENSITY RESIDENTIAL Application valuation: 68000 Applicant: Ta�v 4"X- Qgum BUILDING & SAFETY DEPARTMENT BUILDING PERMIT I Architect or Engineer: lu I APR 13 7011 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Cla s: 10 Lice o.: 845653 XDate: 1i Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 _ 1 I am exempt under Sec. BAP.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Owner: REGNERY ROLLAND J/ROXANNE S 78685 AVENIDA NARANJA LA QUINTA, CA 92253 I(7 ntractor: SERT SOLAR ELECTRIC 096 CLUB ROAD THEDRAL CITY, CA 9223460)831-2032 c. No.: 845653 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 4/12/12 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of'the following declarations: - I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should be uN t to the workers' compensation provisions of Section 700 of the Labor Cod shall Io with ompl ' h th /311 ose provision . `Date: Applicant: WARNING/FAILURE TO SECUR ORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county o enter upon the above-mentioned property f ins action /►/purpos Dat /3 Signature (Applicant or Agentl:LrA A' `%%fR Application Number . . . . . 12-00000295. Permit SOLAR PERMIT Additional desc . Permit Fee 22.50 Plan Check Fee 5.63 Issue Date . . . . Valuation . . 68000 Expiration Date 10/09/12. Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA SOLAR COLLECTOR < 1000 4.50 1.00 3.0000 EA SOLAR EQUIP MISCELLANEOUS 3.00 ------------- -------------------------------------------------------------- Permit . Additional desc : . Permit Fee . . . . Issue Date . . . . Expiration Date . . ELEC-MISCELLANEOUS 22.50 Plan Check Fee . . 5.63 Valuation . . . . 0 10/09/12 Qty ' Unit Charge Per Extension BASE FEE 15.00 1.00 7.5000 EA ELEC PWR APP >1 TO <=10 7.50 ---------------------------------------------------------------------------- Special Notes and Comments 10.5kW.SOLAR ARRAY - (44) 240W SHARP PANELS W/ (1) 9,995W FRONIUS INVERTER [748SF] 2010 CALIFORNIA ELECTRICAL CODE. April 12, 2012 1:39:10 PM AORTEGA 7 ---------------------------------------------------------------------- Other Fees . . . . . . .. BLDG STDS ADMIN (SB1473) 3.00 Fee summary Charged Paid Credited Due ------------------------------------- Permit Fee Total 45.00 .00 -------------------- .00 45.00 Plan Check Total 11.26 ..00 .00 11.26 Other Fee Total 3.00 .00 .00 3.00 Grand Total 59.26 .00 .00 59.26 LQPERMIT Bin. # �1of ulnL Building 8L Safety. Division P.O. Box 1504, 78-495. Calle Tampico La.Quinta, CA 92253 -:(760) 777-7012 Building Permit Application and Tracking Sheet Permit # q Project Address: g (� v Owner's Name:. jS O.L 1i4N0 /?,C— A. P. Number: Address: Legal Description: City, ST, Zip: A �u/XJT� (ft 92Z 5 3 Contractor: DES Telephone: 76d—.j fj —a%�.� •;>'.>�"_�"',��� " Address 6 2,9 9/ e4 4",s 1A0,q D Project Description: City, ST, Zip: C�if7" ��ii�i9G G!T G is? 9.2•� 3 0 0 � Telephone: 7A* 83 -0203 ?ttr • k�,`.;v o N• . .fir. '' `1Ji94 7,¢'/C_ State Lic. # : $ S. S 3 City Lic. Arch., Engr., Designer Address: N City, ST, zip: Telephone: State Lic. #: rte. , N Name of Contact Person: Qom- AGG . Construction Type:. Occupancy: Project type (circle one): New Add'a Alter Repair Demo Sq. Ft.: nes: # Units: Telephone # of Contact Person: 76 a - . 3 i =,9 o 3 a. E ' sled- slue of Project: �r. ez > APPLICANT: DO NOT W BELOW THIS UNE # Submittal Req'd Recd TRACKING IT FEES' Plan Sets Plan Check submitted' Z Z Item Amount Strgcturai Cales. Reviewed, ready for corrections Plan Check Deposit, Truss Cates. Called Contact Person Plan Check Balance Titre 24 Cates. Plans picked up LtJ3 Construction 5Ion-q! Flood plain plan Plans resubmitted. , q1,4 Mecharilcal Giading plan 2'j Review, ready for correctio rsstr Electrical �3 M Subcontactor List Called Contact Person Plumbing r' Grant Deed Pians picked up S hLL H.O-A. Approval Plans resubmitted Grading IN ROUSE:- '^' Review; ready for eorrecdonsfrssue Developer Impact Fee Planning Approval. Called Contact Person Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees. 4 121 01 0-845659 10 KW PHOTOVOLTAIC SYSTEM for Robert Campbell 69096 Club Rd. Cath -1 City, CA .922341 1160.831.2032 Is-t%s CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION Rolland Regnery 78685 Ave Naranja DATE 41 1-2 1101-_ BYADL— La Quinta Ca. 92253 0 � lW fv LOT(S) 1.`5:0F�THE DESERT CLUB TRACT UNIT NO.5 IN THE CITY OF LA QUINTA, IN THE'COUNQTY OF RIVERSIDE, STATE OF CALIFORNIA, AS SHOWN BY MAP ON FILE IN BOOK 21 PAGE(S) 61 AND 62, OF MAPS, RECORDS OF RIVERSIDE COUNTY, CALIFORNIA. 2), Site -Plan 3) 4) Roof Plans 5) 6) 7) 8) Single Line Drawings and Calcuations 9) Rack Mounting Details 10) 11) 12) 13) Fast -Jack Roof Connections 14) 15) 16) Fast Jack Structural Engineering Report 17) Weight Load Analysis 18) 19) 20) 21) Panel and Inverter Specifications 22) Labeling 23) 24) Monitoring APR 0 4 2012 BY° r i ot / • �€�,5cj Wil- �"' . // � � r . • j �. �► + � � a � - • 1 ,F _ -� IAF � a ri ` � F. kr (IT Uo TN ri IL i 1 r �' _ � �� ' .� `� +�""� .1 _ ..� � — � � �''�� , � it •� - - - C r Fl►� ^ "- -.♦ . tea � ��� - r �, � (GOP. as �� _;.f/' =� c;:J� .�J - •+ , . - - � _ `` ♦ � :� 1 � � _ + 12, cz 79 •7 iXn f o L �� riJ ,• i b , , I T- b , • I .} M� s q IL Y13 a yv _ nl nn i r CITY OF LA QUINTAr' N ►h � �. UILDING & SAFETY DEPT. n r APPROVED M , FOR CONSTRUCTION m ? ATE BY -4 Ilk V1 (b fo d ♦`11 J �IL tqb4 X K q �—u uj- t' % q �—u uj- %.#41VuiaLlvlla 411u r-yuiNIIiCIIL QjJWUIIIL CiLIUII0 Equipment Schedule Tag O Component Type Description 1 Solar PV Module Sharp ND-240QCJ 44 Modules - 240W each see Module Ratings below) 2 PV Array 4 Strings of 11 Modules 3 J -Box Determined by Installer 2 Places 4 DC Disconnect Determiners by Installer 30A, 600VDC, Unfused, 2 Places, Capable of interrupting 60OVDC per pole 5 MAC Inverter Fronius IG Plus 10.0-1 10,000W, 240VAC, 4 x 15A fuses see Inverter Ratings below 6 Generation Meter Determined by Installer -- 7 AC Disconnect S uareD DU222RB 60A, 240VAC, 2 -Pole, Unfused, NEMA 3R see 7 8 Service Panel PV Breaker Determined by Installer 60A, 240VAC, 2 -Pole see [11& 4 9 Main Service Panel Existing 225A Bus / 200A Main Conductor Schedule & Am acct Calculations °te" Ta A Description or Conductor Type o C,�► C ,may O �' n o r C M NRZ '� O x y cn N n d S °ly 5 a v 3 d 'd► Cf D 9 � v in O 7 0 .► � < v O tNJ1� 'C UC <D 0 Comments 1 PV -WIRE 10.9 A 13.7 A 1a AWG 28.7 A 15 0.13 (see [2]) D BARE COPPER EGC -- -- tBAWG -- 2 THWN-2 / XHHW-2 10.9 A 13.7 A 10 AWG 20.5 A 25 0.21 n lei INSULATED EGCV. - -- AWG - 3 THWN-2 / XHHW-2 10.9 A 13.7 A 10AWG 20.5 A 6 0.05 INSULATED EGC -- -- �9.,AWG -- 4 INSTALLER DETERMINED AC WIRE 41.7 A 52.1 A 4 AWG 69.7 A 60 0.54 /�/i Ft'i .( 1 °(i INSULATED EGC -- -- i `AWG -- 5 INSTALLER DETERMINED AC WIRE 41.7 A 52.1 A 4 AWG 69.7 A 6 0.05 p i j c 4 '6 INSULATED EGC -- -- f�AWG -- 6 DC GND ELECTRODE -- -- ,VAWG -- PV Module Ratings 0 STC lnvWtQM Manufacturer SharpManufacturerAj '- Fronius Model ND-240QCJ Model IG Plus 10.0-1 Max Power -Point Current(imp) 8.19 A CEC Efficiency Rating Qo -n 1 95.5 Max Power -Point Voltage Vm 29.3 V Maximum DC Volt Rating Cn 600 Open -Circuit Voltage Voc 37.5 V Nominal AC Voltage 240 Short -Circuit Current Isc 8.75 A MPPT Voltage WindowC M jCL 230-500 Max Series Fuse OCPD 15'A Maximum AC Current 41.7 i Maximum Power Pmax 240 W OCPD Rating - - 60 Maximum Power PTC 216.4 W Integrated DC Disconnect M.1 yes Voc Temperature Coefficient -0.36% per °C Inte rated AC Disconnect Ul> Ino Drawn By: DC Power _ System SolarNet Holdings SOLAR Dtoor Copyright 2012 PROJECT NAME: INSTALLER: DESERT SOLAR ELECTRIC Page 2 of 4 Sign for DC Disconnect: Ambient Temperature Assumptions PHOTOVOLTAIC POWER SOURCE FORMULAS Rated MPP Current 32.8 A # of strings x Imp Rated MPP Voltage 322.3 V # of modules in string x Vm Max System Voltage 457.1 V # of modules in strip x Voc + Voc x TcoeffVoc x 0.01 x (Tlow - Trated Max System Current 43.8 A # of strings x Isc x 1.25 WARNING: ELECTRICAL SHOCK HAZARD - LINE AND LOAD MAY BE ENERGIZED IN OPEN POSITION Sign for AC Point of Connection: Ambient Temperature Assumptions INSTALLER: DESERT SOLAR ELECTRIC SOLAR PV SYSTEM AC POINT OF CONNECTION C (7 AC Output Current 41.7 A Installation Zip Code 92201' Nominal AC Voltage 240 V Lowest Expected Tem -5 °C Z � a Highest Temp 44 °C THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR)Avera NEC Table 310.16/310.17 - 75°C Temp. Correction Factor 0.82 Additional Comments: PROJECT NAME: REGNERY INSTALLER: DESERT SOLAR ELECTRIC o C (7 71 0 'U G 0 Z � Q° 0Dr D � c<M0 04D4 M -4 C O Z ® o z �D Drawn By: �t�Y DC Power SolarNet Holdings so[a� E—Pe System Copyright 2012 PROJECT NAME: REGNERY INSTALLER: DESERT SOLAR ELECTRIC Page 3 of 4 Note A: When available, the ASHRAE Extreme Annual Mean:Minimum Temp aridASHRAE 2% Design Temp are used for required low and high temperature calculations. Note B: "Typical Wire Size"_ provided includes ambient temperature adjustment only. Additional derating may be needed based on actual conditions of use; conduit fill conduit location etc... Note C: Wire ampacity is based on 759C copper conductor tables at average highest temperature (due to typical device terminal max, temperature ratings). Technical notes (as applicable): [1]. Circuit breakers without "Line" and "Load" markings are generally appropriate for backfed applications [2] Module -wiring ampacity based on conductor in free air [3] Minimum bus or conductor sized based on sum of ratings of all source over current devices [4] Breaker to be located at opposite end of bus from supply feed and requires "Do Not Relocate". marking [5] "Do Not Tap" or "No Loads Allowed" restriction needed. Requires an Alternate Methods and Materials (AMM) code exception approval. from local AHJ :. . [6] Service Entrance conductor sized Minimum 60A ampacity. [7] Unfused disconnects are generally ]a00%o rated and sized to the actual continuous current. ei y v� �! to e71y —_ -o D Drawn By: REFERENCE NOTES DC Power': SolarNet Holdings SOLAR DEPor `e 4 of -4. SystemsPa _.-- Copyright 2012 STANTIONS ATTACHED TO TRUSSES TRUSSES USING B/e" X 4" SCREW L3 �i�i�iiii�i���ei■ i TYPICAL HOUSE ROOF INSTALLATION TM Integrated with Fast Jack' attachments Roof Troyc ?& patented Roof R(ic" syslem in0alledwilb the RvslRick Mat #6,W,491 attachment vA*Ddprovd& an %*d sohd= for InstaWm The Original "Top -Down" PV Mounting System. wbere aflashing is desired Ybe Fust ftic.0 is also the solar ln&tsfries preferred method ofaffacbmentfor new comftwfim roofs. z F_ Root ha @ & Fast Jack- psoI I i 'under Mud #4360,491 & OUM FftntS Pending. THeTrac@ protected M3dCrRater* #5AQ6,M. on NudhWd A*= is b &ert1s1.1uCk1* affa&nmt swmla* inftyWa uO &el?oqf Rex- ==Yngq.0Wm professional (800).89 -sem So (W3834)8024x LAR 4630 Calle Quetzalproducts- Cffnayfflo, CA 93012 Alt affadvwd A%-i&wv is cmcwkd j!Aft &e stgW rag lmdng an aafhe&aHyPkwft solar arrU- Splice Kit nv splice &prmda a solution to t kd md*k rail s& together. 7be *fice kithas afeature that dkwfor &r - mal expayWon1bon(wdion of the rags wAwd damaging the roof -top! For more information you can visit us on the web at wwwRoojTrac. cora. The Fasi.fack- attacbment provides a quick and strong installation solution. Our patented design places the bolt directly under the stancbzon post wbere it provides the most support This fea- ture allows standard rooffiasbings to layflat on the roof deck. The removable post allowsflasbings to be slipped over the base wilboia damaging surrounding compost- tion omposttion sbingles. FastJack Wfmt 16,360.497 Flashable Roof Stanchion The paw design of the Fastlacko tmr he easily eVessed as the most iimovatia, effluent and wteffednre toot of ifs kind! Bettvem The precision [Tilt madib►ed base and stanchion aloq with strid engineering and material standards, tie fastladc(D has been laboratory tested to provide 2,359 pounds of stimo u1niB only o single lag bob (induded)l Four Sizes Available! 3" High Part# FJ -300-18 For lour profile installations using Oatey© flashings )for composition shingle roof -tops) 4-1/2" High Part# FJ -450-18 For installations using standard floshings (for composition flat rooftops) 6" High Part#. FJ -600-18 For standard flashings (for Rat fife rooftops) 7-1/2" High Part# FJ -750-18 For standard flashings (sized for S-curve file roofs and/or double fleshed installations) The Fast lack's�gn iswared under PaL86X,491 �askgIm5A x93r/R'tagea4 Laboratory Tested 213591bs Vertical Pullout? 808 Mils iide.Isral Fidlout! Fasdack® FJ -300-18 Fur Unirp style floshmp ", FasdackO FJ -450-18 Far standad hqM %shm s Commercial Fastlack© also available (rafted at 4,250 lbs.) Benefits of the FastJack® Easy installation of flashings on Wr x 3w FW w cher roofs �d and say (" Pon makes dafiathe dluswon existing rooftops ss""B*m"O" to lie w See reverse for ingallation theory • Patented dwF !harts the hie bolt di 4 The post can he odorthe sit M'°B sum Standard & Oate flashings installed through "1110dip over the base and under the the fop of the to Wall " sty fm and labor delicate shingle flashing i J • Precision machmed fiam v&udd ahmunuury dere are as szlds to corrode or breafk ' � r • S~ 4fiter dw SW for bstaller conmizaae aid Mdud 4M cam. i 3ttsm X 3-sfz' • hr>r�ated drill guide i d pilot hale , J ss Lag sott any 6me - wiowzes to passilift of splifto t Threaded Fast ta0ftafter3 P .lack Base • Base dedr OHM vatu* any roof BOshiq to -� v •, iM lid an the roof deck Email usfor more information prosola-r0a prosolar com asoq o{ui {sod anIas 'yDue 0 6uisn :q da{S -sni'i 9401- we 6u1ysoiij 6ulysDM E'oi sal6uiys y6n{ {n� l r qoq - �, 97"', japmq lmd3pr MASWav!uN isqu pue Asea &4gsq popw e i -. . u! 6uq�ro say •s6un�g � papuep PUB (pups) hmo J%wgwAv alolduuai 6w4solA o{ui6uiyso�� io wo{{oqJo do{ y6nojy4{sod poa�jy! :s da{S sJagsnM Pa SS u91/S - 8[ sgoq 60l SS �E x „9l/S - 81 sJagsDH PH SS ug/£ - 8l sgoo )(OH SS ,.k/£ x WE - 81 sasoq popDaJg,[ - 8l (1101 a/r[ Jo 9 `ua/[-e `A) mod puno8 u[ - s[ :xoq jad 81 jo sa!Wuonb ui pa6Dpod aio saz!s IIy -sans Pa!uaeum JnoJ u! algD111DAD s! 00f Aq aql 7 'I asog ��o� {sodasoq° puo sa�6 -uiys �apun 6uiysol� apilS :q da{S :U01401104SUl AS03 .90, C6 -aD - -O -4 GD - 6D CD a M ED - Qa co, 11 ClullU000005 It. I-AIAAL mod ojpra f° a6mo{s ml nq algoampau o m paddiqs a nopua ojogd mp ui Bu. pkat' imp= ejoLu'jmppib puo GPm B*Mpod sg('nanplo "o j*w mm ft "d 11n8 � Assembly of the SolarWedge® Attachment Parts List (Per Box) Not to scare Components of the SolarWedge@ Shipped in a shoe box sized package, the SolarWedge XD attachment system easily integrate with the components offer easy handling and storage along with reduced shipping LJ 1 new XD support rail. costs. 1 2 ea. (0 24 ea. � lam Nuri _ ��= 6 ea. 1/2" SS Flat Washers t/2'Washer - - Aluminum Compression = 1•Dia.Aluminum N uts t Compression Rear Posts CG 12 ea. Nut _ 12 ea. 3/8" SS Flat Washers 6 ea. Aluminum 3"XD Roil Lower Raa 36 ea. 1" Dia.Aluminum Front Posts Supports 1/2"S ' • Fro . ; S Jam Nuts ower Support 12 ea. Jam Nut( 1/2"x4'SS 12 ea. 1/2-l*osher_ 12 ea. Leveling _ :' ';Bi`:> ... . - 15- Dia. Studs _ = 3' x 3' Aluminum Seal Plates Aluminum /Jam Nut/: - Bases _ Attachment Box Dimensions ' Specifications are Each box contains enough - - Full Assembled subject to change attachments to f— 6" —7 Y 1 install up to - without notice. 2�\ - 33 kWic Standard SolarWedge®Technical Information ' I > Load Tested and engineered to 30 lbs. per ft' (approx.110mph wind load Illustrated 5" 3.3 kW,, -using 2s0 1sa equivalent) L modules > Utilizes FoamJack8 Laboratory tested to 2,870 lbs. vertical and 2,615 lbs. side lateral pull out using a 3/8" x 6" lag bolt (secured at appro)L 6-1/2"). > Structurally attached to the roof- extremely important in areas with potential horizontal and vertical seismic movement such as California.- > Available in 5' 10' or 15° angles. Optimized to help reduce typical_-_ Rear Extension Height' peak summer demand charges. _ - - ' _ - ' 15 Degree ----; Front Extension Height-__ ----------- -- - AIIAn`gles -- -- -------- --- - -- - — --- 10 Degree ,-- ----- — _ — 6.1rz•+� va• — — — — — 14.1/27+I_3/4• 1 — — _ — — — S Degree — 11•+f-314• ' 'Height rmm roof su,face to bottom of support rail 4' O.0 J Rear View 3" XD Support Rail ' 8' Span between attachments for commercial construction only f' 8' O.C. Drill Guide (Sold Separately) rofessional � (805)486-4700 f'% (805)486 -4799 -fax • B o 1551 S. Rose Ave.�'t S0 o i1 ®• e - ' �z Oxnard, CA 93033 prod�.icts ���, q The FoarrlJackm drill guide ensures that www.prosolar.com pilot holes are drilled 90 degrees to the SWW200W219 fttentE6360,491and D54M7 rafter/beam optimizing the strength and appearance of the connection. V B N C I & ASSOCIATES CUM.Structural Engineers Professional Solar Products, Inc. 1551 S. Rose Ave., Oxnafd, CAL 93033 Tel: 805486-4700 Subject Static load test results for the following: MourdingSyslem Maximum Frame Maldmum Frame load F.quivalentWind Speed Length* (in.) Width* On.) I Qbs/ftz) (mph)•• 1 RoofTrac ® 65 40 1 55 135 TEST SETUP (as shown in attached drawing dem Three modules, as specified above, were bolted to 136xL50x1.5' Professional Solar Products (PSP) patented RoofTface support rails using an assembly of 5/16' Stainless Steel (SS) bolts, SS lock washers and proprietary aluminum clamps and inserts. The RoofTracs support rail was attached to the PSP RoofTrace structural attachment device with a 3/8' SS nut and SS washer at six attachment points. The setup was attached to 2'x6" wooden rafters using 5/16" x 3-1/2" SS lag bolts. The attachment spans consisted of 48" front to rear with structural attachments spaced 48' on center. TEST PROCEDURE (as shawls in sawhed cirawi g dew* The test set up was top loaded to 55 Ib/fix. The setup remained. loaded for an approximate period of 30 minutes. The maximum deflection and any signs of permanent deformation were recorded. The test setup was then inverted and loaded to simulate the uplift condition. The test set up was m -loaded to 55 Ib/ft2. The setup remained loaded for an approximate period of 30 minutes. The maximum deflection and any signs of permanent deformation were recorded. TEST RESULTS: The maximum top load deflection was recorded at 0.469", with no permanent deformation. The maximum uplift deflection was recorded at 0.313", with no permanent deformation. This document certifies the RoofTrac® mounting system used with modules, as specified above, withstands a 55 Ib/R2 static pressure toad, equivalent to a wind speed of approximately 135 mph—. The mounting system performed as expected. Sincerely, James R. Virici, S.E. This engineering report verifies that Vind & Associates has provided Independent observation for load testing as described in this report. The results of this toad test reflect actual deflection vahm and are gamely accepted as the Industry standard for testing module mounting systems. Vind & Associates does not field check instaltatimts or verify that the mounting system is installed as described In this engineering report I. To assist the building inspector in verifying the authenticity of this proprietary mounting system. a permanent adhesion. sliver reflective 'noofrracm' Label, as shown to the rightt, is placed on at least one of the main support rags or permanent y stamped with 'PmfessWnel Solar Prod. Pat 06,3M491* on the underside of rail Structural allachment Lag twit attachment should be installed using the proper pilot hole for optimum strength. A 5/16' lag bolt requires a 3/16;pdot hole It Is the responsibility of the installer to insure a proper attachment is made to the structural memberof theroof Failure to securely attadsto the root structure may result In damage to equipment, personal injury or property damage. This office does not express an opinion as to the load bearing characteristics of the structure the mounting system/modules are being Installed on. =11" 1 ted laboratarytested sVucturel aUacmmYs manufactured by Professional solar products (Including Fastlac ke-. TdeTracs. and FCamlacta) can be interchanged wfdh this system. *Modules measuring within stated specifications and tested to UL1703. or equivalent, are inducted in this engineering. **Wad loading values relative to definked load values using wind load exposure (135 mph for 5/12 root Pitch or less:115 mph for greater than 5/12 roof pitch) and gust factor coe fident -exposure C" as defined in the2006=)/2007(Cac) *** Module tasted: 64.6' x 39.1' x 1.8" (strep) ""Est. snow load rating of 30 Ib/ftz based on 1.6 safely factor Roof Trac \fit ei�oA44i�111 31324 VIA COLINAS STE 101 • WESTLAKE VILLAGE, CA 91362 Page 1 of 3 PSP: RT A Module Area = 18 fl each Total module (45 lbs ea.) and rail (10 lbs ea.)weight: 155 lbs Number of attachments: 6 ea Weight / attachment point: 26 lbs Area: 54 if Distributed weight 2.9 ib/ fig 5/16" Stainless Steel Hex bolt 5/16' Stainless Steel Lock Washer 2,984 5 PIS i 1 Top Load Deflection: 0.469" Im Aluminum ProSolar C1 T1 Inter -Module Clamp Aluminum ProSolar Channel Nut Up lift Deflection: 0.313" Aluminum ProSolar RoofTrac@ Support Rail 3/8' Stainless SteeL l4ex Bolt and Flat Washer Aluminum ProSolarpatentied FastJacW Roof Attachment 5/16' Stainless Steel Lag Bolt and Flat Washer tab tested structural attachments manufactured by Professional Solar Products RoofTrae (Including FasUadcm , TileTracD, and Foamlacte) can be Interchanged %vfth ttdssystem. Solar Modules Prolbsd&W3o/arPmduclsRoof rase Fater*s,3soas+ Static load test Photwottalc mounrag system Page 2 of 3 PSP: -RT FasUack@ 2X bracket only to be used between two rows of modules to maintain approx. 48'upper to lower Roof Trac@ support rail spacing FasUack@ 2X bracket Assembly side view Approx 2(' nor 1--H 5/16"5/16" Stainless Steel Hex bolt and slit lock washer Aluminum ProSolar Inter -Module Clamp Aluminum ProSolar i I Channel Nut EEF3 Aluminum ProSolar Roof Trac@ Support Rail Ic 31 i i i 3B" Stainless Steel Hex Bolts and Flat Washers LV I I Aluminum ProWar FasLlack@) 2X Bracket (arty used between two tows of modules) ._ Aluminum ProSolar Patented 2 pc FastJack@ Roof Attachment 5116' Stainless Steel Lag Bolt and Flat Washer Module Area = 18 ftZ each Total module (451b/ea.) and rail (10 Ib/ea.) weight: 310 lbs Number of attachments: 9 ea Weight / attachment point: 35 lbs Area: 108 ft2 Distributed weight:. 2.9 Ib/ ft2 tab tested structural attachments manufacbaed by Professional solar Products RoofTracs (Including Fastlacrc* , lileTracb. and FoaWacW) can be broerdtanged wtm mussysoem. Solar Modules ftk$siwW SOW ProducO RwfTiae DOWN 6,3W,491 Static load- test Photovoltaic rnounft system Page 3 of 3 PSP: RT WEIGHT LOADING ANALYSIS Solar Electric Installation for Rolland Regnery 78685 Ave Naranja La Quinta Ca. 922,) Roof is a single story with a sloped built top surface and standard wood framing. Wood trusses are 24" on center. Solar stanchions are spaced 6 (six) feet on center. Analysis of dead weight added to roof byarray : Sharp ND-240QCJ 41.9 pounds Number of solar modules 44 Total weight of modules 1843.6 pounds Weight of each "Roof -Trac". 18 pounds Number of sets 24 Total weight of rack sets 432 pounds Total weight of solar array 2275.6 pounds Height of each module 5.5 feet Width of each module. 3.3 feet Area of one module 18.15 sq.ft Area of entire array 798.6 sq.ft Weight of solar array per unit area of roof 2.56 lb/sqft Number of stanchions connected with lag bolts 72 Weight load per stanchion 28.441b/connection See attached sheets for engineering information on the Professional Solar Products "Roof -Trac" racks solar electricity 240 WATT MULTI-PURPOSE MODULE N D-240QCJ MULTI-PURPOSE 240 WATT MODULE FROM THE WORLD'S TRUSTED SOURCE FOR SOLAR. Using breakthrough technology, made possible by nearly 50 years of proprietary research and development, Sharp's ND-240QCJ solar module incorporates an advanced surface texturing process to increase light absorption and improve efficiency. Common applications include commercial and residential grid -tied roof systems as well as ground mounted arrays. Designed to withstand rigorous operating conditions, this module offers high power output per square foot of solar array. Business leaders install this module in large commercial applications, demonstrating financial astuteness and environmental stewardship. ENGINEERING EXCELLENCE High module efficiency for an outstanding balance of size and weight to power and performance. 5% POSITIVE POWER TOLERANCE Count on Sharp to deliver all the watts you pay for with a guaranteed minimum peak power rating of 240 W. Individual modules could test up -to 5% higher. RELIABLE 25 -year limited warranty on power output and 10 -year limited warranty on materials or workmanship. HIGH PERFORMANCE This module uses an advanced surface texturing process to increase light absorption and improve efficiency. "BUY AMERICAN" Proudly manufactured in Memphis, TN from imported and domestic parts. N+^�ru m. r,_vu•vn,...:� mod :s nau.Ar A 0JM m e < ea. jv r.,rl crJr. o �Vc SHARP: THE MAME TO TRUST 240 WATT ND-240QCJ Module output cables: 12 AWG PV Wire ELECTRICAL CHARACTERISTICS Maximum Power (Pmax)' 240 W Tolerance of Pmax +5%/-0% PTC Rating 216.4 W Type of Cell Polycrystalline silicon Cell Configuration 60 in series Open Circuit Voltage (Voc) 37.5 V Maximum Power Voltage (Vpm) 29.3 V Short Circuit Current (Isc) 8.75 A Maximum Power Current (Ipm) 8.19 A Module Efficiency (%) 14.7% Maximum System (DC) Voltage 600 V Series Fuse Rating 15 A NOCT 47.5°C Temperature Coefficient (Pmax) -0.4859,o/°C Temperature Coefficient (Voc) -0.36916/0C Temperature Coefficient (Isc) 0.053%/°C 'Illumination of 1 kW/m' (1 sun) at spectral distribution of AM 1.5 (ASTM E892 global spectral irradiance) at a cell temperature of 25°C. MECHANICAL CHARACTERISTICS - W 7 Dimensions (A x B x C to the right) 39.1' x 64.6" x 1.8"/994 x 1640 x 46 mm Cable Length (G) 43.3'/1100 mm Output Interconnect Cable 12 AWG with SMK Locking Connector Weight 41.9 lbs / 19.0 kg Max Load 50 psf (2400 Pascals) Operating Temperature (cell) -40 to 194°F / -40 to 90°C "PV Wire per UL Subject 4703 QUALIFICATIONS LIL Listed LIL 1703 Fire Rating Class C c&s WARRANTY _ 25 -year limited warranty on power output z Contact Sharp for complete warranty information Design and specifications are subject to change without notice. Sharp is a registered trademark of Sharp Corporation. All other trademarks are property of their respective owners. Cover photo: Solar installation by Pacific Power Management, Auburn CA. 1w, i' DIMENSIONS BACK VIEW SIDE VIEW B C A B C D E 39.1"/994 mm 64.6"/1640 mm 1.8"/46 mm 14.4"/365 mm 3.9"/100 mm F G 37.7'/958 mm 43.371100 mm Contact Sharp for tolerance specifications Sharp solar modules are manufactured in the United States and Japan, and qualify as "American" goods under the "Buy American" clause of the American Recovery and Reinvestment Act (ARRA). SHARP ELECTRONICS CORPORATION 5700 NW Pacific Rim Boulevard, Camas, WA 98607 1 -800 -SOLAR -06 • Email: sharpsolar@sharpusa.com www.sharpusa.com/solar ©2012 Sharp Electronics Corporation. All rights reserved. 11L-105 • PC -03-12 Fronius IG Plus PV Inverter The first complete solution. Reliable. Proven. Smart. ik r r t .m, f . k I An outstanding addition to the family: The next generation Fronius IG Plus inverter builds on a �r successful model with multiple enhancements, including maximum power harvest, a built-in six circuit string combiner, integrated, lockable DC r' Disconnect, significantly improved efficiency, and " — u unbeatable reliability. New, larger power stages expand the proven Fronius IG family from 2 to 12 kW in a single inverter. POWERING YOUR FUTURE INPUT DATA Fronius IG Plus 3.0-1 'Recommended PV-Power(Wp) 2500-; IMPPT-Voltage Range ;DC Startup Voltage Max. Input Voltage (at 1000 W/m2 14°F (-10°C) in open circuit operation) E Nominal input Current 8.3 ,Max. usable Input Current 14.0 ;Admissible conductor size (DC) Number of DC Input Terminals Max. Current per DC Input Terminal 1 3.8-1 I 5.0-1,_ I 6.0-11.... 1 7.5-1 , I 10.0-1 , I 11.4-1 , E 11.4-3 230 ... 500 V 245 V 600 V No. 14 - 6 AWG 6 20 A; Bus bar available for higher input currents 12.0-3 wry 10200-13800 OUTPUT DATA Fronius IG Plus 3.0-1 um, 3.8-1 , 5.0-1 UNI 1 6.0-1 uNl 7.5-1 uN, 10.0-1 uN, 11.4-1 uN1 11.4-3 D,,m 12.0-3 WYE= Nominal output power (PAc_) <3% 3000 W 3800 W 5000 W 6000 W 7500 W 9995 W 11400 W 11400 W 12000 W Max. continuous output power 95.5% n.a. 277 V 95.5% 95.5% 96.0% 96.0% 96.0% 104°F (40°C) 208 V / 240 V / 277 V 3000 W 3800 W 5000 W 6000 W 7500 W 9995 W 11400 W 11400 W 12000 W Nominal AC output voltage 208 V / 240 V / 277 V 208 V / 240 V 277 V Operating AC voltage range 208 V 183 - 229 V (-12 / +10 %) (default) 240 V 211 - 264 V (-12 / +10 %) 277 V 244 - 305 V (-12 / +10 %) Max. continuous 208 V 14.4 A 18.3 A 24.0 A 28.8 A 36.1 A 48.1 A 54.8 A 31.6 A' n.a. output current 240 V 12.5 A 15.8 A 20.8 A 25.0 A 31.3 A 41.7 A 47.5 A 27.4 A7 n.a. 277 V 1 10.8 A 13.7 A 18.1 A 21.7 A 27.1 A 36.1 A 41.2 A n.a. 14.4 A* Admissible conductor size (AC) No. 14 - 4 AWG Max. continuous utility back feed current 0 A ,Nominal output frequency 60 Hz Operating frequency range 59.3 - 60.5 Hz Total harmonic distortion <3% Power factor 1 GENERAL DATA Fronius IG Plus I 3.0-1 UNI I 3.8-1 UNI I 5.0-1 UNI I 6.0-1 uw I 7.5-1 uw I 10.0-1 UNI I 11.4-1 UNI I 11.4-3 0.1. 112.0-3 Nv�r Max. Efficiency 96.2% CEC Efficiency 208 V 95.0% 95.0% 95.5% 95.5% 95.0% 95.0% 95.5% 95.0% n.a. 240 V 95.5% 95.5% 95.5% 96.0% 95.5% 95.5% 96.0% 95.5% n.a. 277 V 95.5% 95.5% 96.0% 96.0% 96.0% 96.0% 96.0% n.a. 96.0% Consumption in standby (night) < 1 W Consumption during operation 8 W 15 W 22W 1 Cooling Controlled forced ventilation, variable fan speed Enclosure Type NEMA 3R Unit Dimensions (W x H x D) 17.1 x 24.8 x 9.6 in. 17.1 x 36.4 x 9.6 in. 17.1 x 48.1 x 9.6 in. I Power Stack Weight 31 lbs. (14 kg) 57 lbs. (26 kg) 82 lbs. (37 kg) Wiring Compartment Weight 24 lbs. (11 kg) 26 lbs. (12 kg) 26 lbs. (12 kg) Admissible ambient operating temperature -4 ... 122°F (-20... +50°C) a ;Compliance UL 1741-2005, IEEE 1547-2003, IEEE 1547.1, ANSI/IEEE C62.41, FCC Part 15 A8 B, NEC Article 690, C22. 2 No. 107.1-01 (Sept. 2001) PROTECTION DEVICES Fronius IG Plus 3.0-1 um, 3.8-1 uN, I 5.0-1 u, I 6.0-1 UNI 7.5-1 u., I 10.0-1 u., I. 11.4-1 UNI I 11.4-3 D.No ( 12.0-3 Ground fault protection Internal GFDI (Ground Fault Detector/Interrupter); in accordance with UL 1741-2005 and NEC Art. 690 DC reverse polarity protection Internal diode i Islanding protection Internal; in accordance with UL 1741-2005, IEEE 1547-2003 and NEC 'Over temperature Output power derating / active cooling • per Phase Fronius USA LLC Solar Electronic Division 10421 Citation Drive, Suite 1100, Brighton, Michigan, 48116 E -Mail: pv-us@fronius.com www.fronius-usa.com N PHOTOVOLTAIC SIGNAGE REQUIREMENTS PER NATIONAL ELECTRICAL CODE NEC 690 nolo Note: Signage on combiner box Is only required If there are overcurrent devices In the ' NEC 705.22 box. MM ��=E When applicable COMBINER • • BOX OPERATING C1.11:11IFNT -19.7 ANIP OPEnAIING VOLTAGE 352 VDC NEC 690.63 When required ON AC SUB -PANEL II DISCONNECT I I' NEC 690.17 OFF METER INVERTER. NEC 690.14(q (2 when appllcable - a � MAIN SERVICE IF . FAULT IS INDICATED, Wh plleeble � e . • • : I NONMALLY GROUNDED m 71 C Dc AND UNGHUNDED DISCONNECT NEC ses.6(q NEC 705,10, and 690.64 6) 0 Ma Z `nI M r� NEC 890.64 co 33� T1 When required i_ < M 0 —4 Recommended signage or labeling specifications: �� C A. Red background with white lettering Note: If the photovoltaic Disconnect Is remote and nrd. B. 3/B" letter height sight from.the Mein Service Disconnect, thenry' z C. All capital letters showing the locations of the Main Service Dis z m .i D. Arial or similar font and the Photovoltaic Disconnect must,be InstD E. Weather resistant material (i.e. engraved plastic) i Locus Product Datasheet ENERGY The LGate 101 can monitor nearly any type of solar energy system. Regardless of inverter or panel type, it can measure energy production with a high degree of accuracy. As a datalogger, it has a variety of digital and analog inputs enabling direct communication with third -party devices such as inverters and meteorological sensors. Performance data is aggregated and uploaded automatically to the Locus Energy Smart Monitoring website which provides custom tools and analytics to all project stakeholders. DATA COLLECTION The LGate uses a hard -wired voltage reference and current transformers (CTs) to measure power. There are inputs for up to three CTs allowing the LGate to measure both solar energy generation and whole -house electrical consumption. It can also gather data from up to 16 third -party devices simultaneously which is collected via RS485 and Modbus RTU protocols. All data feeds are stored in non-volatile memory and then uploaded with unique identifiers to provide maximum fl exibility as to how the data is presented online. NETWORK CONNECTIVITY The LGate 101 is a plug and play device supporting a multitude of connectivity options. It can communicate over Ethernet, powerline carrier (PLC), or cellular networks. Hard -wired Ethernet is the preferred connection method, but if this is unavailable, the LGate features a built in 110V outlet for easy installation of a PLC adapter. Data is transmitted only in outbound sessions over open ports requiring no additional network or firewall configuration. The connection and commissioning process is further simplified by the LGate's LED lights which indicate communication status without installers having to log in or call home. Locus Energy develops web -based asset management software for renewable energy systems. We provide monitoring, analytics and data services for deployments of solar photovoltaic and solar thermal technology. By leveraging Locus' products, renewable finance companies and integrators can drive down the cost and complexity of energy monitoring while making it much easier to maintain and service an installed client base. Founded in 2007, Locus is based in New York City and serves clientele across the world. Locus Energy o ffers Smart Monitoring software services tailored to the ' following groups to help maximize the performance of renewable assets: • Installers • Financiers • Utilities • OEMs • Regulators f DIAGRAM - TYPICAL CONFIGURATION MMM MMM AMM IM110IIIIIII• MMI♦ NIIII♦� MMM MMS PV ARRAY DIMENSIONS 6.000 6.000 0.700 14 3,00 i 6.700 - 6100 I c I.. View -Cover Removed +®_ SPECIFICATIONS 10.000 L l ELECTRICAL Shielded CATS INVERTER SERVICE ARM9 embedded CPU I 00 Current Transducers Memory Voltage Reference Logging interval Standard CATS Display USB -based handheld LCD (optional) LGATE 101 — 4.000 — 2000 its DATALOGGER _ NEMA 311 Type I - Processor v ARM9 embedded CPU I OS Custom version of Linux 2.6, OTA fi rmware updates Memory 128 MB RAM Logging interval 1 to 60 minutes, user selectable (default 5 minutes) Display USB -based handheld LCD (optional) • RS485 2 wire and 4 wire terminals I l Modbus USB i KYZ Pulse 4-20 mA analog COMMUNICATIONS LAN R14S 10/100 Ethernet, full half duplex, auto polarity Cellular GSM/CDMA Add-ons Powerline carrier, Zigbee Networking DHCP or static IP 1.188 INTERNET O 0.875 x 1325 DKO Type pd Type 2 Pts ROTATE HASP 90 I 1.125 x DKO 01375 FOR PACKAGING \ Type #4 r� COMS5240 \ Type 2 PIS 3.063 �I — 4.936 6.813 Bottom View Isometric View POWER r Voltage Inputs 85-264 V Line To Neutral or Line to Line t - . 4 Phases Single phase, Split phase at 50 or 60 Hz L _Current Inputs mA Solid-CoreCTs 200 Amp .75' intemai diameter, mV Split -Core Cfs 200-600A, up to 1.25' internal diameter COMPLIANCE i ANSI C12.20 0.5% IEC 61010 (Safety) FCC 15 Part B IEC 60068-2-2 7 (Mechanical shock) IEC 60068-2-6 (Mechanical Vibration) CFR 47 ANSI C63.4 (Radiated emissions) CAN/CSA - C22.2 (61010-1) I Enclosure _ NEMA 311 Type I - Weight 6 Ib 12 oz Dimensions 10x8.25" x 4.25" j Environment -20 to 70C, 95% RH, non -condensing Warranty 5 year limited warranty for power -meter, data logger