Loading...
07-0496 (AC)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Appl ication'Number. 07-00000496 Property Address:' _ - 78998 MILES AVE APN: 604-032-026- - - Application description: ADDITION - COMMERCIAL Property Zoning: MAJOR COMMUNITY FACILITY Application valuation: 345559 Tiht 4 4 " BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Applicant: Architect or Engineer: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License'Class: B.0-8 LicenseNo.: 599424 Date: /Si O 'Contractor://17Li,�`,L •�D% �.� ^ OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the ' permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is'sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors 'to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improvesthereon,.and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERAIIT Owner: FAMILY HERITAGE CHURCH 78998 MILES AVE LA QUINTA, CA 92253 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 6/08/07 Contractor: A U GENERAL CONSTRUCTION MG , INC 74990 JONI DRIVE SUITE.]7 PALM DESERT, CA 92260 JUN 0 8 2000 (760)779-0477 LiC. No:: 599424 CITYOFLAQUINTA. WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ' _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ' Ihave and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is.issued. My workers' compensation insurance carrier and policy number.are: Carrier STATE FUND Policy Number 2290021384 I certify that, in. the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I s all forthwith comply with thosg provisions. Date: Applicant:.. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the.Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. )J 1 Date: U O Signature' (Applicant or Agent): LQPERMIT . Application Number . . . . .. 07-00000496 ------ Structure Information ADDITION TO CHURCH ----- Construction Type TYPE V - NON RATED Occupancy Type :. ASSY BLDG <300 NO STAGE Other struct info . . CODE EDITION O1BMP04E05EN BASEMENT SQUARE FOOTAGE x.00 FIRE SPRINKLERS YES GARAGE SQ FTG, .00 MIXED-USE OCCUPANCY A-3 OCCUPANT LOAD 144.00 PATIO SQ FTG 1940.00 TOT ELIGIBLE NO 1ST FLOOR SQUARE FOOTAGE 5006.00 Permit . . BUILDING PERMIT Additional desc . Permit Fee 1500.50 . Plan Check Fee 975.33 Issue Date Valuation 345559 Expiration Date 12/05/07 Qty Unit Charge', Per Extension BASE FEE 639.50 .246.00 3.5000 THOU BLDG 100,001-500,000 861.00 Permit ELECT - ADD/ALT/REM Additional desc ... Permit Fee 153.92 Plan Check Fee'. 38.48 Issue Date Valuation. . 0 Expiration Date 12/05/07• Qty. Unit Charge 'Per Extension BASE FEE 15..0 0 6946.00 .0200 7 7 ELEC GARAGE OR -NON-RESIDENTIAL ------------------------------------------------ 138.92 Permit . . MECHANICAL Additional desc . Permit Fee . . . . 268.00 Plan Check Fee 67.00 Issue Date . . . . Valuation . . . . 0 Expiration Date 12,/05/07 Qty Unit Charge Per. Extension BASE FEE 15.00 . 10.00 9.0000 EA MECH FURNACE <=10OK 90.00 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00 8.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 132.00 LQPERMIT . Application Number 07-00000496 Permit MECHANICAL l Qty Unit Charge Per Extension 1.00 6.5000 EA MECH VENT FAN 6.50 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . . PLUMBING: Additional desc Permit Fee . . . . 280.50 Plan Check Fee 70.13 Issue Date . . . . Valuation . . . . 0 Expiration Date 12/05/07 Qty Unit Charge Per Extension. BASE FEE 15.00 27'.00 6.0000 EA PLB FIXTURE. 162.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 8.00 6.0000 EA PLB ROOF DRAIN 48.00 1.00, 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 12.0000 EA PLB INTERCEPTOR 12.00 1.00 3.0000 'EA PLB.WATER INST/ALT/REP 3.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 1.00 15.0000 EA PLB GAS METER 15.00 Special Notes -and Comments .6946 SF"ADDITION TO EXISTING -CHURCH (FAMILY HERITAGE) A-3 OCC. TYPE V -N CONSTR. (3 YARDS AND FIRE SPRINKLER , CREDIT FOR ALLOWABLE AREA TOTAL = 6000 SF X 3 X 2 = 36,000 SF) 2001.CBC,CMC, CPC, 2004 CEC, 2005 ENERGY. **SEPARATE PERMITS) REQUIRED FOR BLOCK WALLS AND TRASH ENCLOSURE** Other Fees ACCESSIBILITY PLAN REVIEW 97.53 ART IN PUBLIC PLACES -COM 1707.79 DIF CIVIC CENTER- COMM 780.93 ENERGY REVIEW FEE 97.53 DIF FIRE PROTECTION -COMM 225.27 STRONG MOTION ("SMI). -COM 72.56 DIF STREET MAINT FAC -COMM 530.63 DIF TRANSPORTATION.- COMM 13.175.79 Fee summary Charged Paid Credited Due Permit Fee Total 2202:.92 .00 .00 2202.82 Plan Check Total 1150.94 .00 ..00 1150.94 Other Fee Total 16688.03 .00 .00 16688.03 m . LQPERMIT - ` �. • :, ,• ; � . r' I -13 _, v b 1 6i, %o • P„b G � t,�a �s . � � f✓7�, rzt:c,�e Bin # t C�. City Of L:a Quinta Building U Safety Division Permit # / r • .� P.O- Boa 1504, 78-495 Cage Tampico , b `.'; La'Quin , CA 92253 - (760) 777-7012 • ' '�� . ' ` ' Building Permit A - pplicatIon and, Tracki�ng Street ` Project Address: "� g a 1 • Owner's Name:- A. P. Number: �O — C)*B� O �-�c�� Address: • �T`��.- t��S �'t�•0�� Legal Description: 5s City, ST, Zip: Contractor: ... `• Telephone: 3�-Cj-0�5 , Address: ! Project Description: ` City, ST, Zip: Telephone: 3 ��5 S E)9N- S 4zlt (wzA State Lic. # City Lic. #• r Arch , Engr., Designer: . Address: City; ST, Zip: Z)E�SER Telephone: 4co Construuctioa Type: �: Occupancy: State Lic. #: Project type (circle one): New . Add'n Alter Repair Demo Name of Contact Person Sq. Ft.: # Siories: , # Units: Telephone # of Contact Person: Cp OA Estimated Value of Project:'. APPLICANT: DO NOT WRITEBELOW THIS UNE. # Submittal Req'd Reed TRACIQNG '{ PERMIT FEES Plaa Sets Plau Check submitted Item Amount . ' Z Structural Calcs. Review y Reviewed; raid for corrections Plan Check Deposit Truss Gies. Called Contact Perron Energy G TD Plan_ Check Balance gG Plans Picked.ap ��// construction Flood plain plan 'b• 1 Plans resubmitted 3 to Mechanical Grading. plan' 2" Review, ready for correctio sae It/07 p? Electrical Subcontaetor List . Called Contact Person Plumbing Grant Deed Plans picked up „ SCi SALL H O.A Approval Plans resubmitted S Grading IN ROUSE:- ''' Review, ready for.correctlowissue--• Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue 4 School Fees 4 .. Total Permit Fees Uc • _• 2//¢ - 2*: 27� C.o c � 4�7 &DO R f:;r> iY CPO Agw.nv, Date 5/23/07 No. 29454 Owner Family Heritage Church Address 79-998 Miles Ave City La Quinta Zip 92253 CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 APN # 604-032-026 Jurisdiction La Quinta Permit # Tract # Study Area Type Church/School /Gov't Facility No. of Units 1 Lot # No. Street Unit 1 78998 Miles Avenue Unit 2 Unit 3 Unit 4 Unit 5 Comments Education Building Addition S.F. 5006 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 Lot # No. Street , S.F. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 5,006 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Vicki Covel Check No. Name on the check Telephone 340.4445 By Dr. Doris Wilson Superintendent Fee collected Signature Funding Exempt Payment Recd 4���F�AScy0 Q BERMUDA DUNES RANCHO MIRAGE (� INDIAN WELLS PALM DESERT y LA QUINTA ,.�. INDIO c S1 CC �r O 604-032-026 Jurisdiction La Quinta Permit # Tract # Study Area Type Church/School /Gov't Facility No. of Units 1 Lot # No. Street Unit 1 78998 Miles Avenue Unit 2 Unit 3 Unit 4 Unit 5 Comments Education Building Addition S.F. 5006 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 Lot # No. Street , S.F. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 5,006 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Vicki Covel Check No. Name on the check Telephone 340.4445 By Dr. Doris Wilson Superintendent Fee collected Signature Funding Exempt Payment Recd NOTICE: Pursuant to Government Code Section 66020(1)(1)/this; will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from thdzWe on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document. NOT VALID if Duplicated Embossed Original - Building DepartmenUApplicant Copy - Applicant/Receipt Copy - Accounting c S1 CC �r _ ,1$0.00 ' Over/Under NOTICE: Pursuant to Government Code Section 66020(1)(1)/this; will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from thdzWe on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document. NOT VALID if Duplicated Embossed Original - Building DepartmenUApplicant Copy - Applicant/Receipt Copy - Accounting C COACHELLA VALLEY WATER DISTRICT ASSESSOR'S PARCEL NUMBER 85-995 Avenue 52 Coachella, California 92236 _ (760) 398-2651 APPLICATION FOR WASTEWATER INTERCEPTOR/SEPARAT OR APPROVAL APPLICANT: Submit this form with a copy of a SCALED plot plan (1" = 20' to 1" = 40' SCALE) drawn to District specifications. A nonrefundable filing fee is required when the application is submitted Chock must be made payable to the Coachella Valley Water District Approval of this application shall remain valid for a period not to exceed one (1) year from date of payment Plan Chock No. Agent, Contractor, Contact Person Address City State Zip Telephone G+KtS rn % 2 - Y 2S FICf4 W*,,ejjJ4 PALyn DA8 6,+ QZ2j,.D 772- A o t Owner fi�t*t(� 1f C`t?bGt E Address City State Zip Telephone -__ M I Lf,5 La QvINTA- 6.4 1'225X 34S -03!5-,S7- Job Property Address ,rA.Aot� city zip Legal Description DBA ■ PLEASE COMPLETE THIS SECTION FOR REVIEW OF FOOD ESTABLISHMENTS NOTE: PLANS WILL NOT BE ACCEPTED UNLESS THIS APPLICATION IS COMPLETE AND THE PLAN CHECK FEE IS PAID. GENERAL CONSTRUCTION: Type of Construction: New Food Facility Remodel of Existing Food Establishment X„_ Hours of Operation Seating Capacity: Internal External External Seating with Misters or Heaters Bar with Food Service Bar Nonfood Service Water Softener Service: Multiservice (reusable) Single Service (disposable) OWNER/REPRESENTATIVE DECLARATION: I certify that I have read the entire application and state that all information is correct I understand that the amount of fee paid is based on my declaration of information on this form and that incorrect information is grounds for denial of the submitted plana. I also understand that plans will be discarded if not picked up within sixty (60) days of approval or denial and that no inspection of my establishment will be conducted, or approval granted to operate, until all proper information requested has been received and plana have been approved and returned. O. . � Signature �/ 7 ` Date W � r � Type of System(s) ■ • ■ -__ 15�Ncw ■ Existing ■ 01teplacement OAddition ■ ■ [3Cozmcct to Sewer • 24 r� - _/!/i. -,NI ,i _ " �• Iii _i i �1 _-� � � /��_ �� .� � L "yam, 1. .i_- _s /.70A1 M -TVs —application is: ■ Denied ■ •� 717 See Remarks - . , Initial Recei red COACHELLA VALI EV WATER Dl9RAICT CASH RECEHxF DEFA A a A -A A w w " j% "(roes: / X — 7 / / ��Unt NO.8�# TrBCt % `� 906 �V—Z/, �•/J�P (�1C� �l/J�1 L .Servios Address G.A. Code ❑. meter(s) ' $ ❑ service(s) - ❑ House Lsteral(s) ❑ Detector Check(s) " ❑ Meter Surcharge { O Sanitation Capacity Charge r . ❑ W.S.B.F.C. _�. ❑ S.I.W.S.C. ❑ Temporary Construction Meter-L- eter 0 ❑ Tum on Qfharge :' - ❑ Uncollected Account — Name ❑ Inspection Fee - Tract — Plan Check Fees Water / Sewer — (' Tract _ U/)•�J/ 1�? /r%�1/I /� 9C4��� DU �� 5 .—❑ ❑ Bond Payment —. A D.- 0Customer Deposit ❑ Other , CTOTAL G�— $ Remertks:'-- Water Cashier TITLE 24 REPORT Title 24. Report for: Family Heritage Church 78-998 Miles e e L"a Quin Fa_,CT 922 3 -Project Designer: Christopher McFadden Architect 72-925 Fred Waring Drive #204 Palm Desert, CA 92260 (760) 346-8014 Report Prepared By: Southwest Group, Inca SOUTHWEST GROUP; INC. 15707 Rockfield Blvd., Suite 235 Irvine, CA 92618 (949) 588-6869, Job Number: . CMA7710 CITY'OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION""', DATFA BY�L-1 a7-4q(c M-vt'ctDN Date: 2/14/2007 The'EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysof..com. EnergyPro 4.1 by EnergySoft Job Number. CMA7710 User Number 4633 V• a TABLE OF CONTENTS Cover Page - 1 Table of Contents 2 Nonresidential Performance Title 24 Forms 3 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 PROJECT NAME This Certificate of Compliance lists the building features and performance specifications needeto comply with Title 24, Parts 1 and 6 of the DATE Family Heritage Church DOCUMENTATION AUTHOR 2/14/2007 PROJECT ADDRESS Southwest Group,Inc. 78-998 Miles Avenue La Quinta � Za The Principal Designer hereby certifys that the proposed building2ee n this set 1s PRINCIPAL DESIGNER -ENVELOPE TELEPHONE BuildirigPirrrii4,#' : •. Christopher McFadden Architect (760) 346-8014 California as a civil engineer, mechanical engineer, or I am a licensed architect. DOCUMENTATION AUTHOR TELEPHONE Checked 6y/Date SOUTHWEST GROUP, INC. 949 588-6869 ;Enf6rceinentA enc .use .. STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needeto comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performan a compliance approach. The documentation preparer hereby certifies that the documentation is accurate and comp te: DOCUMENTATION AUTHOR SIGNAT�deion DAT Southwest Group,Inc. �const�ructiondocuments � Za The Principal Designer hereby certifys that the proposed building2ee n this set 1s consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116, through 118, and 140, 142, 143 or 149 of Title 24, Part 6. ENV. LTG. MECH. 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, or I am a licensed architect. ❑ ❑ 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ ❑ 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ENV -1 Required Forms PRINCIPAL ENVELOPE DESIGNER - NAME SIGNATURE LIC. NO. DATE Christopher McFadden Architect LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures�� TG -1, LTG -2, LTG -3 Required Forms PRINCIP LIGHT114G DESIGNERj NAME LIC. NO. DATE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures , 2. CH -1, MECH-2 MECH-3 MECH-5 Required Forms PRINCIPAL MECHANICAL DESIGNER - NAME SIGN R LIC. NO. DATE Southwest Group, Inc. 11Y733V2 I 3 I EnergyPro 4.1 by EnergySoft User Number. 4633 Job Number: CMA7710 Page:3 of 29 1 PERFORMANCE ,CERTIFICATE OF COMPLIANCE . Part 2 -of 3••' 'I PERFA PROJECT NAME DATE Fei'mifly Heritage Church u ` 2/14/2007' Building Orientation Number of Stories1 Number of Systems Number of Zones N 0 deg Conditioned Floor Area Unconditioned Floor Asea' Conditioned Footprint Area Fuel Type,,Natural 7,631 sqft. sgft: sgft. •k ' ANNUAL TDV ENERGY USE SUMMARY kBtu/s ft- - `" 7,631 10 Standard . Proposed Compliance ENERGY COMPONENT Design Design Margin '.fleag?, £®rwpea„ Space Heating 2.05 1.47 0 57 Wum`T Space Cooling 291.40 286.11 ' �e 5 29SW Indoor Fans 55.96 50.84 -4.88 Mr 1,748 Heat Rejection` 0.00 0.00 0.00 4.4% Pumps & Misc-0.00 ` 0.00 '0.00 �.� Domestic Hot Water 52.61 49.88 2.73 _ ,��z� Lighting 84.22 81.05 x'mss •316 r a`y,./._�,j�t..�. Receptacle 63.s5 , 63.65 �: ', �,�.'� ��.�, Y+.w;t'a�,jC•y Ta�� � 1. 0.001 f x � C�}.F 'R v <A: rt Process o.00 o.00 000 r` - -' • t� 0 20�40�80 80 100;120 140 760 180 200 TL0240260280� TOTALS: 549.89 543.01 . 6.88�w Percent better than Standard: 1.3% ( 1.3% excluding process) . BUILDING COMPLIES Building Orientation Number of Stories1 Number of Systems Number of Zones N 0 deg Conditioned Floor Area Unconditioned Floor Asea' Conditioned Footprint Area Fuel Type,,Natural 7,631 sqft. sgft: sgft. •k ' Gross Area = 'Glazing Area Glazing Ratio 0 8 `" 7,631 10 Gas 1,748 sqft. Remarks: •: Run Initiation Time: 02/14/07 12:20:45 Run Code: 1171484445 EnergyPro 4.1 by EnergySoft User Number. 4633 - Job Number. CMA7710 PageA of 29 - .. '03: j _ .. `• '. .. `�. '.'fir �i �.� Orientation Gross Area = 'Glazing Area Glazing Ratio b , ,Front Elevation N 1,748 sqft. '80 sgft. 4.6% Left Elevation, (E) 1,797 sgft. 48 sgft. 2.7% Rear Elevation S 1,748 sgft. 77 sgft. ' 4.4% r ` Right Elevation (W)_ 1,865 sgft. 64sgft. 34-0/1 ti Total Roof. ' 7,158 7,631 sgft sgft. 269 0 soft. sgft. 3.8016 Standard '.Proposed- r Lighting Power Density 1.269 W/sgft. 1.222 W/sgft. h r ' Prescriptive Env. Heat Loss . " 1,218 Btu/h 1,142 Btu/h:' , Prescriptive Env. Heat Gain 102,726 Btum-F 117,525 Btu/n-F i • • � i Remarks: •: Run Initiation Time: 02/14/07 12:20:45 Run Code: 1171484445 EnergyPro 4.1 by EnergySoft User Number. 4633 - Job Number. CMA7710 PageA of 29 - .. '03: j _ .. `• '. .. `�. '.'fir �i �.� PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 PROJECT NAME Family Heritage Church DATE 2/14/2007 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sgft.) Inst. LPD (W/sf)l Ctrl. I Allowed LPD Credits' Area':: Tailoydd (W/sf)2: Wls 3%Is 4 Proc.` ' Loads (W/sf) HP -10 Nur./Todd/Rest. Zone Classroom, Lecture, Training 1,381 -1.20 HP -7 Off. and Rm. A/B Zone Office 1,270 0.90 HP -5 Room 6 and 8 Zone Convention/Conference/Meeting 830 1.38 HP -4 Room 6 and 7 Zone Convention/Conference/Meeting 830 1.38 HP -3 Room 5 Zone Convention/Conference/Meeting 415 1.38 Storage Zone Corridor/Restroom/Support 415 0.61 HP -2 Room 2 and 4 Zone Convention/Conference/Meeting 830 1.38 HP -1 Room 1 and 3 Zone Convention/Conference/Meeting 830 1.38 HP -6 Kitchen Zone Kitchen, Food Preparation 530 0.96 Restroom Zone Corridor/Restroom/Support 300 1.02 j Notes: 1. See LTG -2-C 2. See LTG4-C 3. See LTG -5-C (items marked with asterisk, see LTG -2 -C by others) (by others) 4. See LTG -6-C Items above require speual documentation . EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System "A.O. Smith BTN 154" is a Large Gas water heater with Pilot Loss = 0 btuh. The HVAC System "HP -10" includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure the airflow. The HVAC System "HP -T' includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure the airflow. i The HVAC System "HP -5" includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure the airflow. I The HVAC System "HP -4" includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure the airflow. The HVAC S stem "HP -3" includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure the airflow. The HVAC System "HP -2" includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure the airflow. The HVAC System "HP -1" includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure the airflow. The HVAC System "HP -6" includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure the airflow. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. - Authorized Sianature or I EnergvPro 4.1 by EnergySoft User Number: 4633 Job Number: CMA7710 Page:5 of 29 1 CERTIFICATE OF COMPLIANCE ENV -1 -CI (PROJECT NAME DATE Family Heritage Church 2/14/2007 OPAQUE SURFACES # Surface Type Area U -Fac. Insulation Cay. Cont. Act. Am. Tilt Cond' Status Joint Appendix IV Reference Location / Comments 1 Roof 1,381 0.049 R-19 R-0.0 0 0 Existing 01-A4 Nur./Todd/Rest. Zone 2 Wall 749 0.102 R-13 R-0.0 270 90 Existing 09-A3 Nur./Todd/Rest. Zone 3 Wall 266 0.102 R-13 R-0.0 0 90 Existin 09-A3 Nur./Todd/Rest. Zone 4 Roof 1,270 0.049 R-19 R-0.0 0 0 Existin 01-A4 Off. and Rm. A/B Zone 5 Wall 699 0.102 R-13 R-0.0 90 90 Existin 09-A3 Off. and Rm. A/B Zone 6 Wall 1 266 0.102 R-13 R-0.0 180 90 Existin 09-A3 Off. and Rm. A/B Zone 7 Roof 830 0.036 R-30 R-0.0 0 0 New 02-A9 Room 6 and 8 Zone 8 Wall 263 0.074 R-19 R-0.0 270 90 New 09-A5 Room 6 and 8 Zone - 9 Wall 462 0.074 R-19 R-0.0 0 90 New 09-A5 Room 6 and 8 Zone 10 Roof 830 0.036 R-30 R-0.0 0 0 New 02-A9 Room 6 and 7 Zone 11 Wall 263 0.074 R-19 R-0.0 270 90 New 09-A5 _ Room 6 and 7 Zone 12 Wall 1 462 0.074 R-19 R-0.0 180 90 New 09-A5 Room 6 and 7 Zone 13 Roof 415 0.036 R-30 R-0.0 0 0 New 02-A9 Room 5 Zone 14 Wall 262 0.074 R-19 R-0.0 90 90 New 09-A5 Room 5 Zone 15 Wall 231 0.074 R-19 R-0.0 0 90 New 09-A5 Room 5 Zone 16 Roof 415 0.036 R-30 R-0.0 0 0 New 02-A9 Storage Zone 17 Wall 262 0.074 R-19 R-0.0 90 90 New 09-A5 Storage Zone 18 Wall 247 0.074 R-19 R-0.01 180 90 New 09 -AS Stora a Zone 19 Roof 830 0.036 R-30 R70.0 0 0 New 02-A9 Room 2 and 4 Zone 20 lWall 263 0.074 R-19 R-0.0 270 90 1 New 09-A5 Room 2 and 4 Zone N, E, A, R (New, Existing, Altered, Removed) FENESTRATION SURFACES More than or equal to 10,000 sq.fL of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default U -factors from Standards Table 116-A and B. Certificate shall be filed in the contractor's oroiect office dudna construction and in the building manner's office after-t-tinn # Tvpe ## Exterior Shade Type Area U -Fac' SHGC2 Act. I Am. I Cond. Stat. Glazing Type Location/ Comments 1 Window Right W 64 1.280 116-A 0.80 116-6 270 Existing Single Metal Clear Nur.(fodd/Rest. Zone 2 Window Left E 48 1.280 116-A 0.80 116-8 90 Existing Single Metal Clear Off. and Rm. A/B Zone 3 Window Front N 32 0.790 116-A 0.70 116-B 0 New Double Metal Clear Room 6 and 8 Zone 4 Window Rear S 32 0.790 116 -Al 0.70 116-B 180 New Double Metal Clear Room 6 and 7 Zone 5 Window Front N 16 0.790 116-A 0.70 116 -BI 0 New Double Metal Clear Room 5 Zone 6 Window Front N 32 0.790 116-A 0.70 116-B 0 New Double Metal Clear Room 2 and 4 Zone 7 Window Rear S 32 0.790 116-A 0.70 116-B 1801 New Double Metal Clear Room 1 and 3 Zone 8 Window Rear S 13 0.790 116-A 0.70 116-8 180 New Double Metal Clear Kitchen Zone (1) LI -factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. 2) SHGC Type: 116-B Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING ## Exterior Shade Type Window Overhang Left Fin Right Fin SHGC Hgt. Wd. Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 1 None 0.76 2 None 0.76 3 None 0.76 4 None 0.76 5 None 0.76 6 None 0.76 7 None 0.76 8 None 0.76 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES The proposed building contains an enclosed space with floor area greater than 25,000 sq.ft, a ceiling height greater than 15 feet and a LPD for general lighting of at least 0.5 W/sq.fL If this box Is checked. ENV4-C must be filled out when submittina under the Prescrlotive Comollance Aooroach. L EnergyPro 4.1 by EnergySoft User Number: 4633 Job Number. CMA7710 Page:6 of 29 1 CERTIFICATE OF COMPLIANCE ENV -1 -C PROJECT NAME DATE Family Heritage Church 2/14/2007 OPAQUE SURFACES # Surface T e Area U -Fac. Insulation Cay. Cont. Act. Am. Tilt Cond. Status Joint Appendix IV Reference Location / Comments 21 Wall 462 0.074 R-19 R-0.0 0 90 New 09-A5 Room 2 and 4 Zone 22 Roof 830 0.036 R-30 - R-0.0 0 0 New 02-A9 _ Room 1 and 3 Zone 23 Wall 263 0.074 R-19 R-0.0 270 90 New 09-A5 Room 1 and 3 Zone 24 Wall 462 0.074 R-19 R-0.01 180 90 New 09-A5 Room 1 and 3 Zone 25 Roof 530 0.036 R-30 R-0.0 0 0 New 02-A9 Kitchen Zone 26 Wall 262 0.074 R-19 R-0.0 90 90 New 09-A5 Kitchen Zone 27 Wall 234 0.074 R-19 R-0.0 180 90 New 09-A5 Kitchen Zone 28 Roof 300 0.036 R-30 R-0.0 0 0 New 02-A9 Restroom Zone 29 Wall 262 0.074 R-19 R-0.0 90 90 New 09-A5 Restroom Zone 30 Wall 247 0.074 R-19 R-0.0 0 90 New 09-A5 Restroom Zone FENESTRATION SURFACES more man or equal to 1u,uuu sq.n. of sae -bunt fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default 1.1 -factors, from Standards Table 116-A and B. Certificate shall be riled in the contractor's project office during construction and in the building manager's office after construction 2 I Azm. t r /u-racior I ype: 110-A uefaua sable from standaros, I able 1,11-1 Uetault Table from the AGM Manual Appendix, NFRC Labeled value. (2) SHGC Type: 116-B Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING Window Overhang Left Fin Right Fin ## Exterior Shade Type SHGC Hgt- Wd. Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES 1:1The proposed building contains an enclosed space with Floor area greater than 25,000 sq.ft, a telling height greater than 15 feet and a LPD for general lighting of at least 0.5 W/sq.fL If this box Is checked. ENV4-C must be filled out when submitttno under the Prnsertntl— Camollanre Ann—rh. I EnergyPro 4.1 by EnergySoft User Number. 4633 Job Number: CMA7710 Paae:7 of 29 1 CERTIFICATE OF COMPLIANCE (Part 1 of 3) LTG -1-C rrcuir-1, i rvwnC DATE Family Heritage Church I 2/14/2007 INSTALLED INDOOR LIGHTING POWER FOR CONDITIONED AND UNCONDITIONED SPACES INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑ COMPLETE BUILDING METHOD (From LTG -5-C) ❑ AREA CATEGORY METHOD (From LTG -5-C) ❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER INSTALLED ALTERNATE COMPLIANCE WATTS INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) 9,069 PORTABLE LIGHTING (From LTG -3-C) 254 LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG -4-C) 0 CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER _9,323 INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑ COMPLETE BUILDING METHOD (From LTG -5-C) ❑ AREA CATEGORY METHOD (From LTG -5-C) ❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER ALLOWED WATTS C9,323 ALTERNATE COMPLIANCE ❑X PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C) 0 MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Dimming, etc.) Check if SPACE CONTROLLED Daoighting ,NOTE'.TO. ;.';FIELQ CERTIFICATE OF COMPLIANCE (Part 3 of 3) LTG -1-C PROJECT NAME Family Heritage Church DATE 2/14/2007 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for lighting systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that require an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the i test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: Before an occupancy permit is granted for a newly constructed building or space, or a new lighting system system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, LTG -1-A, Forms shall be submitted to the building department that: A. Certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of§ 10-103(b) and Title 24 Part 6. Test Description Test Performed By: O LTG -2-A: Lighting Control Acceptance Document - Occupancy Sensor Acceptance - Manual Daylight Controls Acceptance - Automatic Time Switch Control Acceptance Equipment requiring acceptance testing O LTG -3-A: Automatic Daylighting Controls Acceptance Document Equipment requiring acceptance testing EnergyPro 4.1 by EnergySoft User Number: 4633 Job Number. CMA7710 Pape:9 of 29 1 CERTIFICATE OF COMPLIANCE MECH-1-C PROJECT NAME DATE Family Heritage Church 1 2/14/2007 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-I-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates, and operating and maintenance information meet the reouirements of Section 10-1031h1 and Title 94 Part R STATEMENT OF COMPLIANCE ❑ MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit.❑ MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-4-A: Air -Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrord. Units with economizers that are installed at the factory and corli ied with the commission do not require equipment testing but do -require construction inspection. ❑ MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing This test required If the unit serves 5, 000112 of space or less and 25% or more of the ducts are in nonconditioned or semiconditioned space like an attic. New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend duds, replace ducts or replace the packaged unit. - ❑ MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing All new OC V controls installed on naw or existing packaged systems must be tested. ❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing f ' All new VA fen volume controls installed on new or existing systems must be tested ❑ MECH-8-A: -Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chilled and hot water systems. -Automatic Isolation Controls Applies to new boilers and chillers and the primarypumps are connected to a common header. -Supply Water Temperature Reset Controls Applies to new constant flow chilled and hot water systems that have a design capacity greater then or equal to 500,000 atulhr. -Water-loop Heat Pump Controls Applies to all new waterfoop heat pump systems where the combined loop pumps are greater than 5 hp. -Variable Frequency Controls Applies to all new distribution pumps on new variable flow chilled, hydronic heat pump or condenser water systems where the pumps motors are greater then 5 hp. Equipment re uirin acceptance testing EnergyPro 4.1 by EnergySoft User Number. 4633 Job Number: CMA7710 Page. 10 of 29 INDOOR LIGHTING SCHEDULE (Part 1 of 2) LTG -2-C PROJECT NAME - DATE Family Heritage Church 2/14/2007 INSTALLED LIGHTING POWER FOR CONDITIONED SPACES Luminaire I Lamps/Ballasts Installed Watts C D E F G H I _ J Name Type Description rcmc �w '0 �� 333 Myo• 0'�� m m ° r my 3 CD 0) �1N C6%'c 3.m3 5av �•'O� `" a ° r. 3v �m°1 N m m n iym q �' r 3 c X03 al N add -vlm a A (3) 4 ft Fluorescent T8 Rapid Start Elec F32T8 3 3 2J 1.0 96.0 X 661 6.33'6 B P) 26w Compact Fluorescent Triple 4 Pin 26 1.0 26.0 X 21 52 C (2) 4 ft Fluorescent T8 Rapid Start Elec 32r8 2 32 1.0 64.0 X 16 _ 1.024 Standard Allowance: 1381 sgft at 1.200 w/sf 116571 i i i 1 PAGE TOTAL 9 069 BUILDING TOTAL (sum of all pages) 9,069 PORTABLE LIGHTING (From LTG -3-C) 254 CONTROL CREDIT.(From LTG -4-C) ADJUSTED ACTUAL WATTS 9 323 EnergyPro 4.1 by EnergySoft User Number: 4633 Job Number: CMA7710 Paae:11 of 29 1 PORTABLE LIGHTING WORKSHEET LTG -3-C PROJECT NAME Family Heritage Church DATE I 2/14/2007 FEET A TABLE 1 - PORTABLE LIGHTING NOT SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET A B C D ROOM # DEFAULT OR ZONE ID W/s ft AREA SF TOTAL WATTS B X C Off. and Rm B Zoe 0.2 1,270 254 TASK # OF AREA TASK (SF) AREAS TOTAL AREA (SF) (D x E) TOTAL WATTS (C x E) --i TOTAL 1,270 254__ I TABLE 2 - PORTABLE LIGHTING SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET A B 254 C D E F G ROOM # OR ZONE ID PORTABLE LIGHTING Description # OF FIXT. LUMIN. WATTS PE FIXTURE TASK # OF AREA TASK (SF) AREAS TOTAL AREA (SF) (D x E) TOTAL WATTS (C x E) TOTAL 0 0 TABLE 3 - PLANS SHOW PORTABLE LIGHTING IS NOT REQUIRED FOR OFFICE AREAS > 250 SQUARE FEET ROOM # TOTAL AREA OR ZONE ID (SF) TOTALI 0 BUILDING SUMMARY - PORTABLE LIGHTING Designer needs to provide detailed documentation that the lighting level provided by the overhead lighting meets the needs of the space. The details include luminaire types and mounting locations relative to work areas. BUILDING SUMMARY TOTAL AREA (SF) (FROM TABLES 1+2+3) TOTAL WATTS BUILDING TO TAL'i 1,270 254 Run Initiation Time: 02/14/07 12:20:45 Run Code: 1171484445 EnergyPro 4.1 by EnergySoft User Number: 4633 Job Number: CMA7710 Page:12 of 29 MR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C PROJECT NAME DATE Family Heritage Church 2/14%2007 SYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance AIR SYSTEMS, Central or Single Zone HP -10 HP -7 HP -5 112(a) 13.0 SEER / 10.0 EER 13.0 SEER / 10.0 EER Reference on Plans or Specification t 112(a) 7.70 HSPF 7.70 HSPF 7.70 HSPF 112(a) 13.0 SEER / 10.0 EER 13.0 SEER / 10.0 EER 13.0 SEER/ 10.0 EER 112 b Yes Yes Yes 112(c), 115(a) n/a n/a n/a 121(b) Yes Yes Yes 121 b 690 cfm 190 cfm 415 cfm 121 c No No No 121(c) No No No 121(c), 122(e) Programmable Switch Programmable Switch i PrOC Iramrnable Switch 122(e) Heating & Cooling Required Heating & Cooling Require Heating & Cooling Required 122 Gravity Gravity Gravity 122 n/a n/a n/a 123 124 1 R-4.2 I R-4.2 R-4.2 144 a & b n/a n/a n/a 144 a & b 34,352 btuh 25,920 btuh 29,355 btuh 144 a & b n/a n/a n/a 144 a & b 47,862 btuh 24,150 btuh 34,215 btuh 144 c Constant Volume Constant Volume Constant Volume 144 c 144 c Yes Yes Yes 144 d No No No 144 a No Economizer No Economizer No Economizer 144 f Constant Temp Constant Temp �I Constant Tem 144 (f) Constant Temp Constant Temp Constant Temp 144 (k) No No No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A' in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sqf ; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. NOTES TO FIELD - For Buildina Department Use Only EnergyPro 4.1 by EnergySoft User Number. 4633 Job Number: CMA7710 Paae:13 of 29 1 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C PROJECT NAME DATE Family Heritage Church 2/14/2007 SYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance AIR SYSTEMS, Central or Single Zone HP -4 HP -3 HP -2 Reference on Plans or Specification 1 112(a) 7.70 HSPF 7.70 HSPF 7.70 HSPF Reference on Plans or Specification 1 112(a) 7.70 HSPF 7.70 HSPF 7.70 HSPF 112(a) 13.0 SEER / 10.0 EER 13.0 SEER / 10.0 EER 13.0 SEER / 10.0 EER 112(b) 112(c), 115(a) Yes n/a Yes n/a Yes n/a �I1 121(b) Yes Yes Yes 121 b 415 cfm 415 cfm 415 cfm 121 c No No No 121 c No No No 121 c 122(e) Programmable Switch Programmable Switch Programmable Switch 122(e) Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required 122 Gravity Gravity Gravity 122 n/a n/a n/a 123 No No No 124 R-4.2 R-4.2 R-4.2 f 144 a & b n/a n/a n/a 1 144 a & b 29,355 btuh 25,920 btuh 29,355 btuh 144 a & b n/a n/a n/a 144 a & b 34,244 btuh 28,303 btuh 34,215 btuh 144 c Constant Volume Constant Volume Constant Volume 144 c 144 c Yes Yes Yes 144 d No No No 144 a No Economizer No Economizer No Economizer 144 Constant Temp Constant Temp Constant Tem 144 (f) Constant Temp Constant Temp Constant Temp 144 k No No No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. 1-4%J 1 V J 1 V FIGLU - r'VI ou11U 111 VC QI 1111C111 YDC VI11 _ I EnergyPro 4.1 by EnergySoft User Number. 4633 Job Number CMA7710 Page: 14 of 29 1 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C PROJECT NAME DATE Family Heritage Church 2/14/2007 SYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.21` Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance AIR SYSTEMS, Central or Single Zone 7.70 HSPF HP -1 HP -6 1 1 1 Reference on Plans or Specification 1 112(a) 7.70 HSPF 7.70 HSPF 112(a) 13.0 SEER/ 10.0 EER 13.0 SEER / 10.0 EER 112(b) Yes Yes I 112(c), 115(a) n/a n/a _ j 121(b) Yes Yes 121 b) 121 c 415 cfm No 124 cfm No i 121 c No No 121 c 122 a Programmable Switch Programmable Switch 122(e) Heating & Cooling Required Heating & Cooling Required 122(f) Gravity Gravity 122 n/a n/a 123 No No 124 R-4.2 R-4.2 144 a & b n/a n/a 144 a & b 29,355 btuh 34,352 btuh 144 a & b n/a n/a 144 a & b 34,244 btuh 43,486 btuh 144 c Constant Volume Constant Volume 144 c i 144 c Yes Yes 144 d No No 144 a No Economizer No Economizer 144 f Constant Temp Constant Tem 144 (f) Constant Temp Constant Temp 144 k No No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put °N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. I EnergyPro 4.1 by EnergySoft User Number. 4633 Job Number: CMA7710 Page: 15 of 29 1 r WATER SIDE SYSTEM REQUIREMENTS Part 2 of 2 MECH-2-C PROJECT NAME DATE Family Heritage Church 2/14/2007 SYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems MANDATORY MEASURES Equipment Efficiency Pipe Insulation PRESCRIPTIVE MEASURES Calculated Capacity Proposed Capacity Tower Fan Controls Tower Flow Controls Variable Flow System Design Chiller and Boiler Isolation CHW and HHW Reset Controls WLHP Isolation Valves VSD on CHW, CW & WLHP Pumps > 5 HP DP Sensor Location T-24 Section Reference on Plans or Specification' 11 12(a) 123 144(a&b) 144 a & b) 144 h 144 h 144 144 144 144 144 144 1: For each chiller, cooling tower, boiler, and hydronic loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Water side systems include wet side system using other liquids such as glycol or brine. ITEM OR SYSTEM TAG(S) Number of Systems MANDATORY MEASURES Water Heater Certification 113 (a) Water Heater Efficiency 113 b Service Water Heating Installation 113 (c) Pool and Spa Efficiency and Control 114 a Pool and Spa Installation 114 b Pool Heater - No Pilot Light 115 (c) Spa Heater - No Pilot Light 115 d Service Hot Water, Pool Heating DHW Heater DHW Heater 7 1 Reference on Plans or Specification' Chronimite SR -15 n/a n/a n/a n/a A.O. Smith BTN 154 78% n/a n/a n/a 1: For each water heater, pool heat and domestic water loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" ins the column. L- EnergyPro 4.1 by EnergySoft User Number. 4633 Job Number. CMA7710 Paoe:16 of 29 1 MECHANICAL VENTILATION MECH-3-C " 1PROJECT NAME Family Herita DATE 2/1 PRESCRIPTIVE REHEAT LIMITATION (Section 144(d)) MECHANICAL VENTILATION Section 121 (b)2) AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C D E I F I G H I I J K L M N ZONE/SYSTEM D� CL tv 0 to oci n �°-A 0 3 c pp`� 3 x> ci c)� 3 Z oc m o -0-00 ,-n N dl M 3 m�3 xe�i5 vC 9 _ ohm o%O O 0o < D 0 T�.m 3Dr; N o ' T`°° U) 3'0 � gip° 3X N a A ;go - M w3m 7 X A=o T m Cats. �� 'O 5- m .,, m y 1 Nur.lrodd/Rest. Zone 1,38 0.38 525 525 690 HP -10 Total 525 690 Off. and Rm. A/B Zone 1,27C 0.15 190 190 190 HP -7 Total 190 190 Room 6 and 8 Zone HP -5 83C 0.50 415 Total 415 415 415 415 Room 6 and 7 Zone 83C 0.50 415 415 415 HP -4 Total 415 415 Room 5 Zone 41E 0.50 208 208 208 Storage Zone 415 0.15 62 62 208 HP -3 Total 270 415 Room 2 and 4 Zone 83C 0.50 415 415 415 HP -2 Total 415 415 Room 1 and 3 Zone 830 0.50 415 415 415 HP -1 Total 415 415 1 Kitchen Zone Restroom Zone 53 30C 0.15 0.15 80 45 80 45 80 451 1 —�—� HP -6 Total 124 124 C Minimum ventilation rate per Sec on 121 TablA 121 -A E Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant load foregress purposes for spaces without fixed seating. H Required Ventilation Air REO'D V.A. is the larger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS column D or G). I Must be nreater than orequal to H or use Transfer Air column N to make u the difference. u I dm Fan CFM x 30%; or J Design fan supply K Condition area ft. s x 04 cfmlft. s .w or L Maximum of Columns H. J. K. or 300 cfm M This must be less than orequal to Column L and greater that orequal to the sum of Columns H + N. N Transfer air must be provided where the Required Ventilation Air (column H) is greater than the Design Minimum Air (column M). Where required• transfer air must be greater than or equal to the difference between the Required Ventilation Air (column H) and the Design Minimum Air (column M), column H - M. i EnergyPro 4.1 by Ener oft User Number. 4633 Job Number: CMA7710 Page: 17 of 29 MECHANICAL EQUIPMENT DETAILS Part 1 of 2 MECH-5-C PROJECT NAME FamilyHeritage Church IANK INSUL. DATE 2/14/2007 CHILLER AND TOWER SUMMARY Distribution Type Qty Efficiency Tons PUMPS Ext. R -Val. Chronimite SR -15 Equipment Name Equipment Type Qty. Tot. Qty GPM BHP Motor Eff. Drive Eff. Pump Control A.O. Smith BTN 154 Large Gas No Pipe Insulation 1 154,000 81 New 0.78 1.91% 0.01 _ i No Economizer Carrier 50SZ048 Packaged DX 4 47,000 0.0 7.70 HSPF 42,100 13.0 SEER/ 10.0. EER New No Economizer DHW BOILER SUMMARY CENTRAL SYSTEM RATINGS Energy Factor or RE Standby Loss or Pilot IANK INSUL. System Name System Type Distribution Type Qty Rated Input Vol. (Gals.) Condition Status Ext. R -Val. Chronimite SR -15 Instant Elec No Pipe Insulation 7 6,146 0 New 0.98 n/a n/al A.O. Smith BTN 154 Large Gas No Pipe Insulation 1 154,000 81 New 0.78 1.91% 0.01 13.0 SEER / 10.0 EER New No Economizer Carrier 50SZ048 Packaged DX 4 47,000 0.0 7.70 HSPF 42,100 CENTRAL SYSTEM RATINGS HEATING COOLING System Name System Type Qjy Output Aux. kW Eff. Output Efficiency Condition Status _ Economizer Type Carrier 50SZO60 Packaged DX 2 55,000 0.0 7.70 HSPF 52,000 13.0 SEER / 10.0 EER New No Economizer Carrier 50SZO42 Packaged DX 2 41,500 0.0 7.70 HSPF 35,000 13.0 SEER / 10.0 EER New No Economizer Carrier 50SZ048 Packaged DX 4 47,000 0.0 7.70 HSPF 42,100 13.0 SEER/ 10.0. EER New No Economizer I CENTRAL SYSTEM FAN SUMMARY UPPLY FAN RETURN FAN S stem Name Fan Type Motor Location CFM BHP Motor I Eff. Drive Eff. CFM BHP Motor Eff. Drive Eff. Carrier SOSZO60 Constant Volume Draw -Through 2,000 1.00 82.5% 97.0% none Carrier 50SZ042 Constant Volume Draw -Through 1,400 0.50 76.0% 97.0%1 none Carrier 50SZ048 Constant Volume Draw -Through 1,600 0.50 76.0% 97.0% none EnergyPro 4.1 by EnergySoft User Number. 4633 Job Number: CMA7710 Paoe:18 of 29 1 :' ENVELOPE MANDATORY MEASURES ENV -MM rROJ7EIINAME Family Heritage Church 0 DATE 2/14/2007 DESCRIPTIONDesi ner Enforcement § 118(a) Installed Insulating Material'shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3 XJ §118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. FX. §117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. — -- §116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). § 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U -value according to NFRC procedures. §118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value of no less than R-13 between framing members. i i EnergyPro By EnergySoft User Number: User Job Number: CMA7710 Page: 19 of 29 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM • PROJECT NAME DATE Family Heritage Church 1 2/14/2007 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies 0 §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. § 115(a) Fan type central furnaces shall not have a pilot light. ❑ § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. ; §124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be installed with one of the followings § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or § 122(e)1 B An occupancy sensor to control the operating period of the system; or ❑X § 122(e)1C A 4 -hour timer that can be manually operated to control the operating period of the system. F§ 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above.- ❑ § 122(a&b) Each space conditioning system shall be controlled by ah individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. ' 0 § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro By EnergySoft User Number:.User Job Number. CMA7710. Page:20 of 29 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM (PROJECT NAME DATE Family Heritage Church 2/14/2007 § 121(f)l Air Balancing: Thesystem shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or 'F-] § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or F] § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous y basis and displaying that quantity on a readily accessible display divice; or § 121(f)4 Another method approved by the Commission. Service Water Heating Systems El§ 113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. F § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. El § 113(b)3C Lavatories in restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). , Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). EnergyPro By EnergySoft User Number: User Job Number. CMA7710 Paoe:21 of 29 1 Description Designer Enforcement; Ventilation ❑X § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air i openings. § 121(f)l Air Balancing: Thesystem shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or 'F-] § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or F] § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous y basis and displaying that quantity on a readily accessible display divice; or § 121(f)4 Another method approved by the Commission. Service Water Heating Systems El§ 113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. F § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. El § 113(b)3C Lavatories in restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). , Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). EnergyPro By EnergySoft User Number: User Job Number. CMA7710 Paoe:21 of 29 1 t HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Family Heritage Church 2/14/2007 _ SYSTEM NAME FLOOR AREA HP -10 i 1 381 ENGINEERING CHECKS ISYSTEM LOAD Number of Systems 1 Heating System Output per System 55,000 Total Output (Btuh) 55,000 Output (Btuh/sqft) 39.8 Cooling System Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK' CFM Sensible Latent CFM Sensible 4,959 44,076 9,128 L9,,296 19,288 0 --- 964 01 2,204 0 690 25,679 -2,202 r 690 32,000 0 0 2,204 964 74 162 6,926 [753,2171 Carrier 50SZ060 47,862 4,327 34,352 Total Adjusted System Output (Adjusted for Peak Design Conditions) 1 47,862 4,327 34,352 TIME OF SYSTEM PEAK Jul 4 pm an 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 54.5 of '70.7 of 70.7 °I= Outside Air Supply Air Ducts 0:' 690 cfm c Heating Coil Supply Fan 70.2 2000 cfm ROOMS 69.5 of 70.0 of TOOLING SYSTEM 11.0 177.6 OF 310 OW 0 Outside Air 690 cfm 76,0/6B,8 OF 4.1 Return Air Ducts lirstream Temperatures at 88.111-72.00F ® 65.6/64,30F User Number: 4633 Cooling Coil Supply Fan 2000 cfm 65.6 / 64.3 of Supply Air. Ducts 66.6/64.6OF 72.4% R.H. ROOMS 75.0. 68,5 of - Return Air Ducts Job Number: CMA7710 of 29 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Family Heritage Church 2/14/2007 SYSTEM NAME FLOOR AREA HP -7 1,270 ENGINEERING CHECKS ISYSTEM LOAD Number of Systems 1 Heating System Output per System 41,500 Total Output (Btuh) 41,500 Output (Btuh/sqft) 32.7 EATING SYSTEM PSYCHROMETRICS 26.0 of 63.5 of Outside Air 190 cfm 69.4 OF 111.0 / 77.6 of Outside Air 190 cfm 76.0/68,0 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM I Sensible 2,812 28,516 3,80 1,574 17,298 0 1,426 865 —� 0 0 190 7,100 0 -67 190 1 ,803 0 1,426 865 38,468 3 735 27,830 Carrier 50SZ042 24,150 9,516 25,920 Total Adjusted System Output 24,150 9,516 25,920 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 2 pm Jan 12 am ?am Temperatures at Time of Heating Peak) Heating Coil 80.9 OF. 80.9 OF 1) buppry Air uucts � ., Supply Fan 8u.3 �f 1400 cfm ROOMS 70.0 of Return Air Ducts 80,7 1619.5 of 64.5 / 63.6 of 64.5 / 63.6 of Fi- Supply Air Ducts >0^ A+ Cooling Coil Supply Fan 65.5 / 63.9 of 1400 cfm 69.3% R.H. ROOMS 75.0 / 67.7 OF 4.1 by EnergvSoft User Number: 4633 Return Air Ducts `S Job Number: CMA7710 Page: 23 of 29 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Family Heritage Church - DATE 2/14/2007 SYSTEM NAME-� HP -5 _ FLOOR AREA 830 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System I Sensible CFM ISensiblel Latent CFM Output per System 47,000 9,986 Total Room Loads 2,24 22,313 5,484 1,765 Total Output (Btuh) 47,000 11 Return Vented Lighting o Output (Btuh/sgft) 56.6 4991 Return Air Ducts 1,116 Cooling System Return Fan 0 0 Output per System 42,100 Ventilation 415 16,052 -519 415 19,303' Total Output (Btuh) 42,100 0 Supply Fan 0 Total Output (Tons) 3.5 _ 499 Supply Air Ducts 1,116 Total Output (Btuh/sgft) 50.7 30 287 TOTAL SYSTEM LOAD ao 596 a,965 Total Output (sgftlron) 236.6 Air System HVAC EQUIPMENT SELECTION CFM per System 1,600 Carrier 50SZ048 34,215 7,025 29,355 Airflow (cfm) 1,600 Airflow (cfm/sgft) 1.93 _I Airflow (cfm/Ton) 456.1 Total Adjusted System Output (Adjusted for Peak Design Conditions) 34,2151 7,025 29,355 Outside Air (%) 25.9 Outside Air (cfm/sgft) 0.50 TIME OF SYSTEM PEAK Jul 3 pm Jan 12 ann Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of Outside Air 415 cfm 58.4 of 75.6of 75.6 OF Heating Coil Supply Fan 1600 cfm Supply Air Ducts 75.3 OF ROOMS 69.7 OF 70.0 of Return Air Ducts f J DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 1 12.01,'7.9 of Outside Air 85.1 .•' 70.9 OF 65.0 163.8 OF 65.0163.8 OF Supply Air Ducts 415 cfm Cooling Coil Supply Fan 65.6 J 64.0 of 1600 cfm 70.3% R.H. ROOMS 75, 7 % 6i3.2 F 75.3 % Ub.0 (" Return Air Ducts I EnergyPro 4.1 by EnergySoft User Number. 4633 Job Number: CMA7710 Page:24 of 29� EnergyPro 4.1 by EnergySoft User Number. 4633 Job Number: CMA7710 Page:25 of 29 J HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY :77-] PROJECT NAME Family Heritage Church DATE 2/14/2007 SYSTEM NAME HP -4 FLOOR AREA 830 ENGINEERING CHECKS ISYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM ISensiblel Latent CFM I Sensible Output per System 47,000 Total Room Loads 2,358 23,325 5,484 L1,765 _ 9,986 Total Output (Btuh) 47,000 Return Vented Lighting i 0 Output (Btuh/sgft) 56.6 Return Air Ducts 1,166 499 Cooling System Return Fan 0 I Output per System 42,100 Ventilation 415 —o 16,031 -533 415 19,30331 Total Output (Btuh) 42,100 Supply Fan 0 0 Total Output (Tons) 3.5 Supply Air Ducts 1,166 499 Total Output (Btuh/sqft) 50.7 TOTAL SYSTEM LOAD 41,745 4 95 30 287 Total Output (sgftrron) 236.6 Air System HVAC EQUIPMENT SELECTION CFM per System 1,600 Carrier 50SZ048 34,244 7,008 29,355 Airflow (cfm) 1,600 Airflow (cfm/sgft) 1.93 Airflow (cfm/Ton) 456.1 Total Adjusted System Output34 244 7,008 29,355 (Adjusted for Peak Design Conditions) Outside Air (%) 25 9 Outside Air (cfm/sgft) 0.50 TIME OF SYSTEM PEAK Aug 3 pm Jan 12 am Note: values above given at ARI conditions i EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of Outside Air 415 cfm 58.4 of 75.6°F 75.6 OF y. e SOF Heating Coil Supply Fan 1600 cfm Supply Air Ducts 75.a F ROOMS 69.7 of 70.0 of Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 2.0/77.9 of Outside Air 135.1 170,9 of 65.0 / 63.8 OF 65.0 / 63.8 of e:. Supply Air Ducts 415 cfm Cooling Coil Supply Fan 65.7 / 64.0 OF 1600 cfm 70.3% R.H. ROOMS 7.5.7 %68.2 of ?5.% 63. "'= Return Air Ducts ' EnergyPro 4.1 by EnergySoft User Number. 4633 Job Number: CMA7710 Page:25 of 29 J HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME •' Family He SYSTEM NAME HP -3 A 7a Church Number of Systems 1 Heating System Output per System 41,500 Total Output (Btuh) 41,500 Output (Btuh/sqft) 50.0 Cooling System Output per System 35,000 2,88 20,931 26.0 of Outside �� 415 cfm 69.5 of i 12.0. 77.9 OF ) --;ll Outside Air 415 cfm 75.7: 69,8 of EnergyPro 4.1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 2/14/2007 FLOOR AREA 830 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent LCFM Sensible 70.0 of Return Air Ducts I 2,88 20,931 5,484 3,587 13,643 415 0 --- --- — -- -2,972 415 1,047 6821I 0 16,029 ---�—.------0! 19,230 0 0 1,047 682 39,0631 2,5121 34,238 Carrier 50SZO42 28,303 6,829 25,920 Total Adjusted System Output 28,303 6,829 25,920 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm an 12 am PSYCHROMETRICS (Airstream Te 56.6 of 7111 74.0 of Heating Coil 74.0 0l: O� `r a Supply Air Ducts Supply Fan 73.6 of 1400 cfm ROOMS 70.0 of Return Air Ducts I lirstream Temperatures at Time of Cooling Peak) 196.5 172.3 of 67.5166.2 of 67.5 / 66.2 OF Supply Air Ducts Or'c Cooling Coil Supply Fan 68.2 / 66.4 of 1400 cfm 76.7% R.H. ROOMS S.G i 69.6 'f RE I User Number. 4633 eturn Alr Ducts Job Number. CMA7710 26 of 29 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Family Heritage Church 2/14/2007 SYSTEM NAME FLOOR AREA HP -2 830 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 47,000 Total Output (Btuh) 47,000 Output (Btuh/sgft) 56.6 0 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 1 2,24 22,313 0 5,484 11765 -519 415 9,986 49991 19,303 1,116 415 16,052 0 0 1,116 499 40,5961 4,9651 30 287 Airflow (cfm) 1,600 Carrier 50SZ048 34,215 7,025 29,3551 1 Airflow (cfm/sqft) 1.93 Airflow (cfm/Ton) 456.1 Outside Air (%) 25 9 Total Adjusted System Output 34 215 7, — 29,355 (Adjusted for Peak Design Conditions) Outside Air (cfm/sgft) 0.50 TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 58.4 °F 75.6 `�F 75.6 OF Wr ��" '=` Supply Air Ducts Outside Air 0. 415 cfm "';':z� , )F Heating Coil Supply Fan (5i 3 . 1600 cfm ROOMS 69.7 of 70.0 OF IE Return Air Ducts 112.0' 77.9 of Outside Air 415 cfm 75,7/68,2 of 4_1 85.1 > 7iJ.9 of 65.0 / 63.8 of 65.0163.8 of ... `" Supply Air Ducts Cooling Coil Supply Fan 65.6 / 64.0 of 1600 cfm 70.3% R.H. ROOMS 75.i1 ? 68.0 Return Air Ducts User Number: 4633 Job Number: CMA7710 of 2! HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Family Heritage Church 2/14/2007 SYSTEM NAME FLOOR AREA HP -1 830 ENGINEERING CHECKS Number of Systems 1 Heating System Output per System 47,000 Total Output (Btuh) 47,000 :ATING S 26.0 of Outside Air 415 cfm 69.7 of 58.4 of Heating Coil Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK, CFM Sensible Latent CFM 1 Sensible] 41,745 4.951 L 30,287] j arrier 50SZO48 34,244 7,008 29,355 Total Adjusted System Output 244 7,008 29,355 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 3 pm Jan 12 am; im Temperatures at Time of Heating Peak) 75.6 OF 75.6 OF Supply Air Ducts Supply Fan '71,.3 OF 1600 cfm ROOMS 70.0 of i Return Air Ducts DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 1 12.0177.9 OF 85.1. 70.9 OF 65.0 / 63.8 of 65.0 / 63.8 OF Supply Air DuCts� :..ti Outside Air 415 cfm Cooling Coil Supply Fan 65.7 / 64.0 of 1600 cfm 70.3% R.H. ROOMS 7,5,7/6&2 of 75.0 ! 68.% CIF Return Air Ducts < I Energyrro 4.1 by EnergySoft User Number. 4633 Job Number: CMA7710 Page:28 of 29 c. I 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Family Heritage Church 2/14/2007__ SYSTEM NAME FLOOR AREA —� HP -6 830 26.0 of ?� Outside Air 124 cfm 69.7 OF 97 n OF COOLING SYSTEM PSYCHROMETRICS 1 111.0 177.6 of Outside Air 124 cfm 75.4? 63.0 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM FSensible 1 887 16,471 2,48499 13,549 0 824 677 0 0 124 4,716 1,985 124 5,788 0 0 824 677 22,834 4,4691 20-6911 Carrier 50SZ060 43,486 2,319 34,352 Total Adjusted System Output43,486 2,319 34,352 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Sam Temperatures at Time of Heating Peak) ,93.10F Heating Coil .y Supply Air Ducts Supply Fan 82.8 OF 2000 cfm ROOMS 70.0 of _ I h Return Air Ducts ',I 77.6/64.10F W 57.2/56.10F Cooling Coil Supply Fan 2000 cfm 57.2 / 56.1 of -> Supply Air Ducts 57.6/56.2OF 51.5% R.H. ROOMS 75.01 n2. n OF II4E Return Air Ducts `S I EnergyPro 4.1 by EnergySoft User Number: 4633 Job Number: CMA7710 Page:29 of 29 Certificate of Occupancy YC,y �1 3 y G� �.�w Y Buildin & Department of g Safety � r This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building ` construction and/or use. BUILDING ADDRESS :478=998 -MILES AVE -- I Use classification: FAMILY HERITAGE CHURCH Building Permit No.: 07-496 4 � ' Occupancy Group: A-3 Type of Construction: VN Land Use Zone: RL t s t Owner of Building: FAMILY HERITAGE CHURCH Address: 78-998 MILES AVE i S City, ST, ZIP: LA QUINTA, CA 92253 „r.. By: STEVE TRAXEL Date: MARCH 21, 2008 Building Official t POST IN A CONSPICUOUS PLACE •