Loading...
BRES2014-111278-495 CALLE TAMPICOT Ct:. 0 D i �NtII�Cl/ LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BRES2014-1112 Property Address: 51120 AVENIDA CARRANZA APN: 773061006 Application Description: FIRE RESTORATION Property Zoning: Application Valuation: $80,000.00 Applicant: VANTAGE POINT CONSTRUCTION INC 0 OUTSIDE CITY LIMITS LA QUINTA, CA 92253 OCT 23 2014 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License No.: :LIC -0006784 Date: — Contractor: DEPARTMENTI OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (__j I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale: (Sec. 7044, Business and Professions Code: The Contractors' State License law does not apply to an owner of property who builds or improves thereon, and who does the work himself.or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion,.the owner -builder will have the burden of proving that he or she did. not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting. with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'. State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/23/2014 Owner: JACK HOCHANADEL 51120 AVENIDA CARRANZA LA QUINTA, CA 92253, Contractor: VANTAGE POINT CONSTRUCTION INC 0 OUTSIDE CITY LIMITS LA QUINTA, CA 92253 (760)340-5160 Llc. No.: :LIC -0006784 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier:— Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date:k-) t/ 7 Applicant: 7 WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Eachperson upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission. related to the work being performed under or following issuance of this permit. 2. Any permit issued as a'result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct., I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon th bove- mentioned property for inspection purposes. Date: —lel Signature (Applicant or Agent): 5>�=4'S4^..'LN",:...a'-'i_.�V.,;.`uiR;4�'""*€wxt':.'. �,Sd,l�*':x'f.: a".'_�•.y .�, �'A ' €T r HOURLY PLAN CHECK -YES 101-0000-42600 1:5 $105.00 $105.00 10/23/14 541 ac,:�_� ���. '�� z ••••.�' =.�=x..Tz :.. � -t.. <s �"'. ' _��x�ra:, "�•-*^'-����a� .,�".'' w�� t �:w> ..�>:x� bE• �`� �s�:xa�>h .��_:r`;�,E � VANTAGE POINT CONSTRUCTION INC;- CHECK MR130 . 13452 KHE Total Paid forBLDG CITY STAFF - PER HOUR: $10S:00 $105.00 51 -N -b' '': Y"' 's,iDESCRIRTION 1 v. r'_��ja-- 4'kv :k3nSa�ol.. iiA r %`va: m= 'ACCOUNT t`r i'GSi.'$�.,'$3e TYt ; i`'4:a.'i,;tes 'u .a.'x-E'twz'i'E'. °AMOUNT,? `kn 1`.. I PAIDPOATE r �s 3?w.'z•; ,ix �,_..3_.trt�.._a.`..,:as:! _1::7zi ..n_!z_ ,_ ".a.>.. _`^fix. s.�;x„,-a :W.?AY # z s;€.,.t'i.:,�..�.: i:.i3 _,:h......F... L`.X::.ae;f'', S�€.✓v.U`2.._f....x.xt5.3r)?>'r£''#:{Fr0.'Y.-i... kr sP.AID.t t,?%.ivfi?:GS7:iesriT'dJ;''.`.:..a,t':si�w� k'a e;.<nM.'m�..k...l: �•i:S�. BSAS S61473 FEE ; 101-0000-20306. 0 $4.00 $4.00 10/23/14 S:7x ka- rirx'°ss YiC": -. :S` g.Y,41 ,......@, 'kM.<fl,:Y# i :� PAID BYfi 4 e. METMOD 3 x Y. :'f.3 : Rr A k +. H4�>�, 4 CHECK # 3- " 4 CLTO BY >.. �> a za. , ae,: .. t rex Via. . _ ?RECEIPT# „ , . xt a_n ..: �F :..a. ?s _ i VANTAGE POINT CONSTRUCTION INC! CHECK MR130' ; 13452. KHE Total`Pald forBUILDING STANDARDS ADMINISTRATION BSA $4.00 $4.00 . S'3.. N....aA .N 'ugAi�.'i.,1," h,".&:.:. 4.2._'xx A.a" Ta z'.ja 5. T'' 4xT#kx.'. SCRIPTION ,... ...`•. ,:.. i.,. '` A000UNTOR TsY ' M PAID `� k . 5c U t :exe.:tk..•.-...a'k'.-«<'�i.t :;et?'L1,'a".._''....b<.v,`_s,.F::i•",f'§'n....:�s:.cs.-,£.,vE. q: AMOUNT ", -- t o y� s -,..,<:Ma::i Rz{d:.f.a ,Y:-,::is<s'ms P,AIO'Di4TE? Y6h _<?•)y�N3Y,: Fo.;.S RESIDENTIAL, ,EAADDITION 1,000SF ' 101-0000-42403 0 .$12.33 $12.33 ` 10/23/14 :'- +.��.---yys,.,y� r::.:tS''f'h'S;_",'os;:e^ay,. ;R`s,Y. .''?,' �., tx-:. tliroZD'+r £ "3 `. "n` 5•r i §'F'ro �`-.,F '"' '� PAID;BY "'::.: ..,v!:,....5v`.,r-•-.. L•:°"ha"Sc ^c":zif i 'Ge'Y ,i `, METHODxr, "-.+` '.yam-..:,i:�'i<?ic'"".x�:d< 3t ''i. S aAi �{E # ` 't r�,b•,F "Y .6s.,.t�..0 ..f.0 >• CHECKWY,N ... ,w.gyk`t+ ta.y:.. . _.x:b :,u'::i'"�W.�YSsw':i42''�v,`v' _ �P _vx. "`..'F.:...:zL',k,_�F+J.�3.:__'vxri!�Ai:✓A`e'�vv.,Yam'•vi.._f::r...x.,!_:->..,,n3GFS:..rmAY-2v:.aYiii....Y!<R:te.__{, ,RECEIPT , ;a LTU BY , VANTAGE POINT CONSTRUCTION INC CHECK MR130 13452 KHE t,Ei . �v DESCRIPTIONS a �d:'�E `A c'.. >d "> xa. X'. :, ff.-i-::x. AMOUNT x g'', a,zY'= �c -3 y�.a D� 4 t=i•�-.... d _`lN,..x, PA1 MDAW xA r# k',ACCOUNT <+tet' ._.>,,3.: x QTtY vw5sAPA�., # r S: yA u RESIDENTIAL, EA ADDITION 1,000SF, PC . 101-0000-42600. ,' 0 $5.08.- $5.08 10/23/14 x PAID BYZ� -bsr il:?.xs.,..t«*Ed. a.. u METHODa��xx E�,F - bi cs, irgytiry'.,^.:'rzx yaws vim`' a: ` as,- ";'� .y" isr n. .,ri"'•k rt?�E� x r 1'x € A! �' 7} ;?i.*<`f r., tFN-IR yRECE1P,T# xCHECK�#tf �,CC70 VANTAGE POINT CONSTRUCTION INC CHECK . " MR130 13452 KHE +`?ex'a>'" `i.4 _ iFS;. s'.%ri,Y•Yd'h': `F".- Y.`i e:: : ?, C I'Y3 SnS AA.�'.:.i<' A-f'I N. i "'y3 � �F DESCRIPTION t t 1 ,iF < S• 's:}L ruse ACCOUNT#> Yw. YO` ssy AMOUNT A. G L4 �dR +ng. ''. i a�.X QW, PE11D "I =8!FkiEe x¢tdf Y PAID DATE, r z :.°a.u'S,K�Ew; ,'^'. iV._.:.. h�AA;.;4Wa?_d:, ..3 cw ::6.6''a..•vFs axi .._-1w 9'.EiArzvA , .' f ., -.a;.<+,'Y''r-'3'�ar'°h„<ib. x ? 4m RESIDENTIAL, FIRST.I,000SF. 101-0000-42403' 0 .$145..'03 $145:03," .. 10/23/14 � :.V -a Kt.�',t';s, 7 rr """'sk.. ;".e�' . - r.: Sn. "r,r:4_ `7zj _. ~a a.SIM,7 3PAID BY a a, < ":r fir„ .,,. : "wa - Sz., --,:y: _ `. _ b z ra,sk METHODS t C' o�?t"s-:. •amu v RECEIPT`t# f. "N';:Eg: w >% x .� aCLTOBY.wr -e nwx5'=l?r c! x x a s. .uy _�.?:a:.„.._: ,..v".,T<t,;_,...3,.c;i..zY�^.'.::<'.:.:�Yi.<:a.t:,.;..r-a'r,ai:,...isE'v...<as:.:.,.:.i,. t a`x;,,�x,�:-, <_31...ru..r3ESs: t� n v ....s.t .:s.usx. i<: _ :-:r _:.h._.:i,3k� __.:•".�. r KC, c> a �T 5::.5,:t;_,<..x-n,..Sr_.k_�uVS'?Y1'a r; ... isx :2.._EY dxr<•t:3: VANTAGE POINT CONSTRUCTION INC CHECK MR130 13452 KHE Sry:4# z3 a"A 1y f ra..:Y+`I. 5.1m*.. 3+i ""4 _. _rI, i' 'i'r ',`-.' '"E: OESCRIP,:.TIONil ,iw ti: :•�5� A Y' x:,ti a ,k,r s� ACCOUNT � i M1 QTY i{C :.'.!`Yc S ' '' AMOUNT 4 JE' a3F"h 9i MI s PAID ? ` yPAID DATE . >" C Yd s. "\.. ., „k ,,.S_a..:rT.� r.... _ ... 4t.' .a_ ... ., ,,taut. �x. m. "r 4.. >*S E a G.'n ..r:"tY:a^. -`E,>i _:,.,. .xk. ski".7'T-, r a r ,. Vit..'..-: x•2 N RESIDENTIAL, FIRST 1,000SF,•PC �. 101-0000-42600 0 $47.86 _ $47.86, 10/23/14 -€;.', w-'..: .7".ir'a' ....... -'x . "�•t,''. T ,`zk ,'`•, ,�}xy'Y'x,*s. Y: v'4• �5- . 3 4. t ra .1•' - j m t P.QID.`BYK {{�.:'ti..i �R;- RE>-<hi;_wP - 4 b3:• ,�. }"F' v' 1 r . z S 3'>.� METHOD �s, t.. �'4: ` RECEIPT# E � ,; ::=o-,',�.g 'r_ �^s♦. 3 -''i.tX F fah 1 tCHECK�#s41, T Ke^t;<g'• s '�.< S�CLTD BY a roe Tgft .f 4'i1g �. &Kan•7. c:,...,- < , VANTAGE POINT CONSTRUCTION'INC CHECK-. , MR130, 13452 KHE Total Paid for ELECTRICAL - NEW CONSTRUCTION: $21.040'. $210:30 .:e:� �. -,. ,�<u.»."i°'SLn:.S 4_axc.ii:.vmr��1:3tiE"4.y"x J.4.-r*+....f .Y.. thy'➢. ,A.p :2E,.M+x'-•?:L'k'k_:i.!:• `.a1 S. ,u'a r i 7�,� s ii t " P,s'f e PAIDr PAID DATE: sAMOUNT 4. _'> E< Pp. 9 FURNACE -101-0000-42402 • 0 $36.26 $36.26 , 10/23/14: .,.X •,.: dF^�,r > �<..kf-as 'xy ^'%T " #Y "i k '. s PAID BY -r^� aR::><;.rr t t :,a,.-� ^3�,. •€& 7 .rte ". t. L43' �;.. .:,,�c x,�i'• `'ss'. 'ti cE t :t4 i R # EOEiPT: s. zYx a:.:,,. rt F c. •vS` ` {h �x'�" CHECK #f * ,A.cw: CLTD BYE? _ w --s- ;r;.,, :i',Y :x;+r;iM. ,- ,00.1METHQD A *:< >. ; .gr a s, €.:Yu'aY:> ?4., - VANTAGE POINT CONSTRUCTION.INC CHECK.' MR130 _ 13452, KHE h ,"•YyS }r �( 1`^ , ....� t_ ?w � DESCRIPTIONK� " i 3S: i•ER:' --rrn "x1.:-%`k'hT. ACCOUNT P: ii"rg.. Fw?, "t"'f: ::pF '"F: F �kAMOUNT :'H -y. ,vi, PAID �* ��, t.i" nf`ar PAID"UAT,E; .:.<�. , : ...._,.tv:• :.,kT:.a-End.;..M..`.;,k.'x`.....F.+Yv,.",znE.i^.Z.�+^31(E:.xyk`.rria:.?:i'.4'K-z< QTYF ,S,r, 4, „ >,_ , ._.<kxx �r4.nu.w;�z-, FURNACE PC . 101-0000-42600 0 $24.17. $24.17 .10/23/14. ,.�<^'v :r.:".:. a' Ee:•,-_ �_ maw '�ct�:sT'" x rRal<.{rr Ft' ',t z . E E;�'X'i ry? - . i.. .v , O . A'k,&�,.�"Y E, x,, PAID:BIfy:�.>)E '..2-m i'd's„t�.-e ;'. E°-,o�i!:'6i�:"€. ..-... Y�" .t 3 i i �s.R�. :A>.3 .rF;",Y✓-,kr e METHOD • . 4:i A, R,�t3".- RECEIPT # x" vL r CHECK•i#ia� iCLTDMBY€« e•{�, _6: ..:_a�a'. P< < R._,'"?,`!'? eESC�``.5.°eI,.e:::�rE.:3.;eE3�(1:?:,,;.t.x:.A.;a-�:'tn; f3�S,..:u>.r*-sw_:.2,';,xxi;.:>=;i•x5i; ".�s;s:a_a�'d..:Ps>.ist;. VANTAGE POINT CONSTRUCTION INC CHECK MR130 13452 KHE _ Total Paid forMECHANICAL: $60:43' $60.43 K -- LYtY>F.s }.saztw:-,..yL" PACCOUNT# .,Yx' �'x-aw< {"PA Nac ,^_._ _r....r3.sx_...s#. :c'a:..>,_,3 ..>wK�Y .ar;S.:r.,,. _x .3.x .....u( .:>: ,rT^€` . .:.S- t ,. 5.2,,::x. »'sYx: _.7, >,_,..fi.::.tr-:rbRr,.J:.`l:.i: >•r,ri -r:- ..1,"n"'aTF <4 REMODEL, EA ADDITIONAL 500 SF -i 101-0000-42400 0 $65.25 $65:25 10/23/14 a&Pi`w`N -'y.. r ::.PAIDfBY� s r -°x. '. "a. F`^: ..'i:, ka:PE .zn- "-r ,METFiOD`r 1' ^# „'"+ � ?:4'�Svw=' t,'£ W: C^ t.a a 051-,< �,.�,€t .�Ys'-. :.'G`, s kt-:?a:�§'<r•t>tr:;7AF 3 ,3,•r,�"„ ���CLTDrBY ,a5,r,rar.;RECEIPT#� VANTAGE POINT CONSTRUCTION INC CHECK MR130 13452 KHE li!'r, --p `41� -�7 sn. pr.. " ME R. M KM 17 — 1�w S. PRN M DESCRIPTIONkL 0 I D",; DATE* "PRE REMODEL, EA ADDITIONAI500 SF PC 101-0000-42600 0 $52.20 $52.20 10/23/14 =-5: ......... x3':'--8;y-'#5wMJ RECEIR E M VANTAGE POINT CONSTRUCTION INC1 CHECK MR130 13452 KHE J; T"'�g'ygj�rirp i4�Mk.' Mlft m An a V 411�;: A im 'PAIUDATE-, _"B REMODEL, FIRST 100 SF 101-0000-42400 $49.31 $49.31 10/23/14 METHOD gxp�v­ RECEIPT;# -HEC X X IT N ANN IYMNY VANTAGE POINT CONSTRUCTION. INC CHECK MR130", 13452 KHE NO, 0 I ;­ g, h %v" n " �' RM�,-'IAMOUNT4 R W&I" . tv 'PAl D� DATE' , - i� I En""olonz NNJ" REMODEL, FIRST 500 SF PC 101-0000-42600 .'0 $134.88 $134.88 10/23/14 0 NSM j - z ;2 g"'I", gggli g" - g""�t4'", "�'& �4 IPMM' 'RE E -i'#­-AA0-.'�-"-w, CHEC -', s, qtw VANTAGE POINT CONSTRUCTION INC, CHECK MR130 13452 KHE Total Paid forREMODEL: $301.64 $301.64 i up ig p -nmT-�T-_ pggm 6"t - AMOUNT. 0 I ft,PAID4 PAIDMATE - imp ..'m I'm SMI - RESIDENTIAL 101-0000-20308 0 $10.140 $10.40. 19/23/14 aw a a METHOD SIR VANTAGE POINT CONSTRUCTION INC � CHECK MI1130 13452 KHE Total Paid-forSTRONG MOTION INSTRUMENTATION SMI:. $10.40 $10.40 _Tu�p '_tk � . ��' "i . ". 3 iii 42 QTY %2 w4- 1. MIN 10 U N Ty -Il- - RAM "PAIDQ�u MDR 94A DOOR/WINDOW, REPLACE FIRST 7 101-0000-42400 0 $60.91 $60.91 10/23/14 M-w METHOD} -m 0 E. 7 LBYH a MR, gg IMM00- AIR fl;" .VANTAGE POINT CONSTRUCTION INC -.CHECK MR130-. - 13452-' KHE qt. k I ofl- -0 On,' `8 V 2 0,00 - MIR AIM Z,0 AIMI� �:..!AMOUNTi�*fl NO DOOR/WINDOW, REPLACE, EA ADDITION 5 101-0000-42400 0 -$36.45 $30.45 10/23/14 -gg�;tp .!hR_q 'V-�.h , -, ' �g �, �' -fi .4-ru z4'; -V '-NAMAIM _.;"'...'_ii qg M ETT, H 0 D �i.j 'DT t I Pmwgi fC H E'CkW'r-p`1M g XLTD-BY�1i, t1l"01 :w h1l VANTAGE POINT,CONSTRUCTION INC CHECK- MR130' 13452- KHE H 1p� gr"g T.), 4 �,MAI QMIM Tw�c'N DOOR/WINDOW, REPLACE, EA ADDITION 5 .101-00,00-42660' 0' $34;86 $34.80 10/23/14 PC. X kj"% OF% W "METHOD '--­'$z;"kL"MW �'Wk R -0 1f, 0, gg'v gm.m'CHECKXT`��"­_ g �Ie-i'.,'ggv,�� C VANTAGE POINT -CONSTRUCTION INC CHECK MR130 13452 KHE -Wr 'Pla.' N5 �`;wc 4PKe Ra AMOUNT` i.? VA 3;.' �PA DOOR/WINDOW, REPLACE, FIRST 7 PC 101-0000=42600 042600 $110.22 $110.22 10/23/14 —11 'umg� ps. n Rg_ . ..... VANTAGE POINT CONSTRUCTION INC CHECK MR130' 13452 KHE Total Paid for WI NDO!W/SLiDl NG'GLASS DO'O'R/FENESTRATION: $236.38. $236.38, • Raw— Description: FIRE RESTORATION CHRONOLOGY ^ Type: BUILDING, RESIDENTIAL Subtype: REMODEL Status: APPROVED Applied: 9/17/2014 MFA Approved: Parcel No: 773061006 Site Address: 51120 AVENIDA CARRANZA LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 73 Lot: 17 Issued: UNIT 9 FROM CONSULTANT KAY HENSEL Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $80,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 10/17/2014 Details: FIRE RESTORATION. REPAIR FRONT PORCH. REPLACE ALL DOORS/WINDOWS. REPLACE HVAC SYSTEM. REPLACE ELECTRICAL. REPLACE ALL DAMAGED FINISHES. 9/17/2014 Printed: Thursday, October 23, 2014 12:24:04 PM 1 of 4 EmAr sysTrms CHRONOLOGY CHRONOLOGYTYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES PLAN CHECK COMMENTS FROM CONSULTANT KAY HENSEL 10/1/2014 10/1/2014 RECEIVED RESUBMITTAL KAY HENSEL 10/17/2014 10/17/2014 PER JJ, KEEP RESUBMITTAL IN HOUSE FOR PLAN CHECK SENT TO PLAN CHECK KAY HENSEL 9/17/2014 CONSULTANT ADVISED CURTIS SHUPE THAT THE PLANS ARE APPROVED TELEPHONE CALL ARMEN ALTOUNIAN 10/20/2014 10/20/2014 PENDING HE PROVIDE STAMP/SIGNATURE FOR STRUCTURAL PORTION OF WORK ALONG WITH REGISTERED TITLE -24. TELEPHONE CALL JIM JOHNSON 10/1/2014 10/1/2014 CALLED APPLICANT TO PICK UP CORRECTIONS CONDITIONS Printed: Thursday, October 23, 2014 12:24:04 PM 1 of 4 EmAr sysTrms NAME TYPE NAME ADDRESSI CONTACTS CITY STATE ZIP PHONE FAX EMAIL APPLICANT VANTAGE POINT CONSTRUCTION INC 0 OUTSIDE CITY LIMITS LA QUINTA CA 92253 Total Paid for BLDG CITY STAFF - PER HOUR: $105.00 $105.00 BSAS SB1473 FEE 101-0000-20306 CONTRACTOR VANTAGE POINT CONSTRUCTION INC 0 OUTSIDE CITY LIMITS LA QUINTA CA 92253 CHECK VANTAGE POINT KHE OWNER JACK HOCHANADEL 51120 AVENIDA CARRANZA LA QUINTA CA 92253 FINANCIAL ••• DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD. PAID BY CLTD BY HOURLY PLAN CHECK - 101-0000-42600 1.5 $105.00 $105.00 10/23/14 MR130 13452 CHECK VANTAGE POINT KHE YES CONSTRUCTION INC Total Paid for BLDG CITY STAFF - PER HOUR: $105.00 $105.00 BSAS SB1473 FEE 101-0000-20306 0 $4.00 $4.00 10/23/14 MR130 13452 CHECK VANTAGE POINT KHE CONSTRUCTION INC Total Paid forBUILDING STANDARDS ADMINISTRATION $4.00 $4.00 BSA: RESIDENTIAL, EA 101-0000-42403 0 $12.33 $12.33 10/23/14 MR130 13452 CHECK VANTAGE POINT KHE ADDITION 1,000SF CONSTRUCTION INC RESIDENTIAL, EA 101-0000-42600 0 $5.08 $5.08 10/23/14 MR130 13452 CHECK VANTAGE POINT KHE ADDITION 1,000SF, PC CONSTRUCTION INC RESIDENTIAL, FIRST 101-0000-42403 0 $145.03 $145.03 10/23/14 MR130 13452 CHECK VANTAGE POINT KHE' 1,0005E CONSTRUCTION INC RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 $47.86 10/23/14 MR130 13452 CHECK VANTAGE POINT KHE 1,000SF, PC CONSTRUCTION INC Total Paid forELECTRICAL - NEW CONSTRUCTION: $210.30 $210.30 FURNACE 101-0000=42402 0 $36.26 $36.26 10/23/14 MR130 13452 CHECK VANTAGE POINT KHE CONSTRUCTION INC FURNACE PC 101-0000-42600 0 $24.17 $24.17 10/23/14 MR130 13452 CHECK VANTAGE POINT KHE CONSTRUCTION INC Total Paid forMECHANICAL: $60.43 $60.43 Printed: Thursday, October 23, 2014 12:2404 PM 2 of 4 SYSTEMS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY REMODEL, EA 101-0000-42400 0 $65.25 $65.25 10/23/14 MR130 13452 CHECK VANTAGE POINT KHE ADDITIONAL 500 SF CONSTRUCTION INC REMODEL, EA - 101-0000-42600 0 $52.20 $52.20 10/23/14 MR130 13452 CHECK VANTAGE POINT KHE ADDITIONAL 500 SF PC CONSTRUCTION INC REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 $49.31 10/23/14 MR130 13452 CHECK VANTAGE POINT KHE CONSTRUCTION INC REMODEL, FIRST 500 SF 101-0000-42600 0 $134.88 $134.88 10/23/14 MR130 13452 CHECK. VANTAGE POINT KHE PC • CONSTRUCTION INC Total Paid for REMODEL: $301.64 $301.64 SMI - RESIDENTIAL 101-0000-203080 $10.40 $10.40 10/23/14 MR130 13452 CHECK VANTAGE POINT KHE CONSTRUCTION INC Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $10.40 $10.40 DOOR/WINDOW, 101-0000-42400 0 $60.91 $60.91 10/23/14 MR130 13452 CHECK VANTAGE POINT KHE REPLACE FIRST 7 CONSTRUCTION INC DOOR/WINDOW, REPLACE, EA ADDITION 101-0000-42400 0 $30.45 $30.45 10/23/14 MR130 13452 CHECK VANTAGE POINT KHE CONSTRUCTION INC 5' DOOR/WINDOW, REPLACE, EA ADDITION 101-0000-42600 0 $34.80 $34.80 10/23/14 MR130 13452 CHECK VANTAGE POINT KHE 5 PC CONSTRUCTION INC DOOR/WINDOW, 101-0000-42600 0 $110.22 $110.22 10/23/14 MR130 13452 CHECK VANTAGE POINT KHE REPLACE, FIRST 7 PC CONSTRUCTION INC Total Paid for WINDOW/SLIDING GLASS $236.38 $236.38 DOOR/FENESTRATION: TOTALS: $928.15 $928.15 Printed: Thursday, October 23, 2014 12:24:04 PM 3 of 4 CfflAJF IYU SYSTEMS BOND INFnRMATION ATTACHMENTS Attachment Type PARENTPROJECTS •, N/S 1ST REVIEW S1-120 AVENIDA RETURNED REVIEWS STATUS REMARKS REVIEW TYPE REVIEWER SENT DATE DUE DATE NOTES DATE ARMEN 9/17/2014 9/24/2014 9/23/2014 REVISIONS REQUIRED 1ST REVIEW RFC NON-STRUCTURAL 1ST REVIEW RFC ALTOUNIAN ARMEN 9/17/2014 9/24/2014 10/1/2014 REVISIONS REQUIRED 1ST REVIEW RFC STRUCTURAL 1ST. PLAN CHECK CORRECTIONS ALTOUNIAN ARMEN APPROVED W/ APPROVED PENDING TITLE -24 REGISTRATION. NON-STRUCTURAL 10/17/2014 10/31/2014 10/23/2014 APPROVED CONTRACTOR PROVIDED REGISTERED TITLE -24. ALTOUNIAN CONDITIONS APPROVED PENDING STAMP/SIGNATURE FROM BUILDING LICENSED ENGINEER/ARCHITECT FRONT STRUCTURAL BUCKET 10/17/2014 10/31/2014 10/23/2014 APPROVED 2ND PLAN CHECK PORCH RESTORATION.. CONTRACTOR PROVIDED STAMP FROM ENGINEER BOND INFnRMATION ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED N/S 1ST REVIEW S1-120 AVENIDA DOC 9/23/2014 ARMEN ALTOUNIAN COMMENTS.docx CARRANZA.docx 0 Printed: Thursday, October 23, 2014 12:24:04 PM 4 of 4 SYSTGiv15 Bin #ilk City of La Quinta Building 8r Safety Division ` ' I P.O. Box 1504, 78-495 Calle Tampico . La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking -Sheet Permit # Project Address: V Owner's Name: A. P. Number:Al -114 Address: S l Legal Description: City, ST, Zip: Contractor: V Telephone: Address: _ e�✓ Project.Description: �i•il City, ST, Zip: c a. C TTelephone: - State Lic. # : City Lic-C. Arch., Engr., Designer: Address: � - City., ST, Zip: Telephone: _ :.: .... ........... ........................ Construction Occu ancY-YPe: State Lic. Pro'ect type circle one New Add'n Alter Repair Demo Name of Contact Person. i Sq. FL: # Storie : #Units: Telephone # of Contact Person: Estimated Value of Project: G d �/ o -C2ZS7'0 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACIQNG PERMIT FEES Plan Sets 3 Q Plan Check submitted / 17 Item Amount Structural Calcs. 15 Reviewed, ready for corrections O 1 Plan Check Deposit Truss Calcs. Called Contact Person loll Plan Check Balance. Title 24 Calcs. p? Plans picked up i,®2 Construction Flood plain plan Plans resubmitted I%-% Mechanical Grading plan 2"" Review, ready for correction issue fl�0 Electrical Subcontactor List Called Contact Person 10 Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN IiOUSE:- 'rd Review, ready for correctionslissue Developer Impact Fee * Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fecs 9//7 q jai N/S � �a �ODI ��rn "(2- x/30 �'°/-L-3. 7 ,AfPPo Ab rt4j65)g,6 jMJ;C�) I Or CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Description: Title 24 Analysis Calculation Date/Time: 14:23, Wed, Oct 22, 2014 Input File Name: Residence Avenida Carrenza Renovation.xml CF1 R -PRF -01 Page 1 of 7 GENERAL INFORMATION 01 Project Name Single Fam Detached ` 02 Calculation Description Title 24 Analysis 03 This building incorporates one or more Special Features shown below 03 Project Location 51120 Avenida Carranza 04 CA City La Quinta 05 Standards Version Compliance 2014 06 Zip code 07 Compliance Manager Version BEMCmpMgr 2013-3 (651). 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 270 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 1290 15 Number of Zones 1 16 Slab Area (FT2) 1290 17 Number of Stories 1 18 Addition Cond. Floor Area 0 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) 0 21 Glazing Percentage (%) 13.3% COMPLIANCE RESULTS 01 Building Complies with Computer Performance ` 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 2.11 2.97 -0.86 -40.8% Space Cooling 137.61 136.41 1.20 0.9% IAQ Ventilation 0.00 0.00 0.00 -- 0.0% Water Heating 15.32 15.32 0.00 0.0% Photovoltaic Offset ---- 0.00 0.00 --- TOTAL 155.04 154.70 Oo34 0 Registration Number: 214-A0123799A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2014-10-2310:16:25 Report Version - CF1R-10172014-651 '-Jr vy UUINTA BUILDING & SAFETY DEPT. APPROVE® FOR CONSTRUCTION DATEBY I HERS r vi er: CaICERTS inc. Report Generated at 2014--1015:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Single Fam Detached Calculation Datelrime: 14:23, Wed, Oct 22, 2014 Page 2 of 7 Calculation Description: Title 24 Analysis Input File Name: Residence Avenida Carrenza Renovation.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts with high level of insulation • Window overhangs and/or fins PROJECT HERS FEATURES The following are project -level features that must be field -verified as a condition for meeting the modeled energy performance for this computer analysis. These, plus any additional HERS features listed in the building components tables below, requre field verification by a certified HERS Rater. Building -level Verifications: None -- Cooling System Verifications: • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Verified low -leakage ducts located entirely in conditioned space Domestic Hot Water System Verifications: --None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2)• 212.81 212.47 0.34 0.2% includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING FEATURE INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Single Fam Detached 1290 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height tt + f s Y OF Water ati y e erlEIdatirfg'S tem 2 Existing Living Conditioned Living Zone1 1290 9 DHW�S,ysM-1 ' Registration Number: 214-A0123799A-000000000-0000 Registration Date/Time: 2014-10-23 10:16:25 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 LDA'ffbSProvider: OR CONSTRUCTION By Cal ERTS inc. 4:25:2 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 14:23, Wed, Oct 22, 2014 Calculation Description: Title 24 Analysis Input File Name: Residence Avenida Carrenza Renovation.xml CF1 R -PRF -01 Page 3 of 7 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (W) Window and Door Area (ft) Tilt(deg ) Status Verified Existing Condition Front Wall Existing Living Default Wall 1978 to 1991 270 Front 430 40 90 Existing No Left Wall Existing Living Default Wall 1978 to 1991 0 Left 300 94.984 90 Existing No Rear Wall Existing Living Default Wall 1978 to 1991 90 Back 550 Left Wall 90 Existing No Right Wall Existing Living Default Wall 1978 to 1991 180 Right 380 36 90 Existing No Roof Existing Living Default Roof 1978 to Pres Window 6 Left Wall 1290 5.0 1 Existing No ATTIC 01 02 03 04 05 06 09 10 11 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condifion Attic Attic Roof Cons 0 0.1 0.85 No No Existing No WINDOWS 01 02 03 04 05- 06 07 '08 09 10 11 Name Side of Building Width(ft ) Height (ft) Multiplie r Area (ft2) U -factor SHGC Verified Existing Exterior Shading Status Condition Window Front Wall 4.0 5.0 1 20.0 0.60 0.50 Insect Screen (default) Altered N/A Window 2 Front Wall 4.0 5.0 1 20.0 0.60 0.50 Insect Screen (default) Altered N/A Window 3 Left Wall 6.0 6.8 0.98 40.0 0.60 0.50 Insect Screen (default) Altered N/A Window 4 Left Wall 3.0 3.0 1 9.0 0.60 0.50 Insect Screen (default) Altered N/A Window 5 Left Wall 3.0 2.0 1 6.0 0.60 0.50 Insect Screen (default) Altered N/A Window 6 Left Wall 4.0 5.0 1 20.0 0.60 0.50 Insect Screen (default) Altered N/A Window 7 Left Wall 5.0 4.0 1 20.0 0.60 0.50 Insect Screen (default) Altered N/A Window 8 Right Wall 5.0 4.0 1 20.0 0.60 0.50 1pseep - cr erV e -aIt) ere 01%1 look N/A Window 9 Right Wall 4.0 4.0 1 16.0 0.60 0.50 Ins'e°ct Scree efa 1 ii W N/A Registration Number: 214-A0123799A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2014-10-23 10:16:25 Report Version - CF1R-10172014-651 ovit_u1114U O< 0/Hr1= I Y UEP-� APPROVED FOR CONSTRUCTION DAT65+,,� . BY Report inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation DatefTime: 14:23, Wed, Oct 22, 2014 Calculation Description: Title 24 Analysis Input File Name: Residence Avenida Carrenza Renovation.xml CF1 R -PRF -01 Page 4of7 OVERHANGS AND FINS 01 02 03 04 05 Construction Name Surface Type f Framing Total Cavity R -value Assembly Layers Zone Area (W) 01 02 03 04 05 06 07 08 09 10 11 12 13 1 14 none - I tit✓ LLII lip g S Overhang • Inside Finish: Gypsum Board Default Wall 1978 to 1991 Exterior Walls Left Fin R 11 Cavity/Frame: R-11 /2x4 Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up Window 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 2 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 3 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 4 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 5 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 6 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 7 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 8 2 0.1 2 2 0 0 0 1 0 0 0 0 0 0 Window 9 2 1 0.1 2 2 0 0 0 1 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS • 01 02 03 04 05 Construction Name Surface Type f Framing Total Cavity R -value Assembly Layers Zone Area (W) 2x4 Top Chord of Roof Ci,/ Edge Insul. R -value _ Cavity / Frame: no insul. / 2x4 Top Chrd Attic Roof Cons Attic Roofs Truss @ 24 in. O.C. no insulation - Roof Deck: Wood Siding/sheathing/decking p� t Covered Slab Existing Living 1290 • Roofing: Light Roof (Asphalt Shingle) none - I tit✓ LLII lip g S XFW Y • Inside Finish: Gypsum Board Default Wall 1978 to 1991 Exterior Walls 2x4 @ 16 in. O.C. R 11 Cavity/Frame: R-11 /2x4 • Exterior Finish: Wood Siding/sheathing/decking • Inside Finish: Gypsum Board Default Roof 1978 to Pres Ceilings (below attic) 2x4 @ 16 in. O.C. R 22 Cavity/Frame: R-9.1 /2x4 • Over Floor Joists: R-12.9 insul. SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (W) Perimeter (ft) Ci,/ Edge Insul. R -value _ Verified Existing Condition Ca eted Fraion ct '� a ed p� t Covered Slab Existing Living 1290 80 none - I tit✓ LLII lip g S XFW Y La -. Ti g No Registration Number: 214-A0123799A-000000000-0000 Registration Date/Time: 2014-10-23 10:16:25 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 A Jf-"HUVEU FOR CONSTRUCTION DATE_rov��! CaiCERTS inc. Report Generated at 2014-10 22 14:25:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Description: Title 24 Analysis Calculation Date/Time: 14:23, Wed, Oct 22, 2014 Input File Name: Residence Avenida Carrenza Renovation.xml CF1 R -PRF -01 Page 5of7 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (011) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required -- WATER HEATING SYSTEMS 01 02 01 02 03 04 05 06 Name Distribution Type Number of Heaters Solar Fraction (%) Status Verified Existing Condition DHW Sys 1 Standard 1 Annual Existing No WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.62 EF 40000-Btu/hr 0 0.04 WATER HEATING - HERS VERIFICATION 01 02 ,03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a n/a n/a n/a n/a HVAC SYSTEMS 01 02 03 04 05 06 07 08 09 Heating System Cooling System Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition Living Zonal Other Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 1290 Altered No Cooling System Component 1 Component 1 System 1 1 HVAC - HEATING SYSTEMS 01 02 BUILDINGa SAFErf DEPT. 113 Name Type I Effi4 iency Heating Component 1 CntrlFurnace - Fuel -fired central furnace FOR COi STRUCTIO 80 FUE Registration Number: 214-A0123799A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance IDATE BY Registration Date/Time: 2014-10-23 10:16:25 HERS Provider: CaICERTS inc. Report Version - CF1R-10172014-651 Report Generated at 2014-10-22 14:25:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Description: Title 24 Analysis Calculation Date/Time: 14:23, Wed, Oct 22, 2014 Input File Name: Residence Avenida Carrenza Renovation.xml CF1 R -PRF -01 Page 6 of 7 HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 Name Verified Airflow Efficiency Verified EER Multi -speed Verified Refrigerant Charge Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 PkgAirCond - Central packaged A/C 11.3 13 No No Cooling Component Duct Leakage: system (< 65 kBtuh) Location Location Bypass Duct Status 1 -hers -cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool Required 350 Not Required Not Required Not Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 01 02 03 04 05 06 07 08 09 08 --- --- Insulation Supply Duct Return Duct Verify Existing HERS Name Type Duct Leakage: R -value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located entirely in Existing (notConditioned 8 Conditioned None Existing No N/A System 1 conditioned space s`specified) . Zone Zone HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1 -hers -dist N/A --- --- --- HVAC - FAN SYSTEMS & HERS VERIFICATION _ 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 equired CITY OF LA QUIN I A BUILDING & SRFPT. APPROVED FOR CONSTRUCTION Registration Number: 214-A0123799A-000000000-0000 Registration Date/Time: 2014-10-23 10:6 25 TE----NE^RS8Y Provider CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at 2014-10-22 14:25:27 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Description: Title 24 Analysis Calculation Date/Time: 14:23, Wed, Oct 22, 2014 Input File Name: Residence Avenida Carrenza Renovation.xml CF1 R -PRF -01 Page 7 of 7 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: �r/• � loan d aclzer Joan Hacker Company: Signature Date: Joan Hacker 2014-10-23 10:15:53 Address: CEA/HERS Certification Identification (If applicable): 77810 Las Montanas Road, Suite 201 City/State/Zip: Phone: Palm Desert, CA 92211 760-345-1352 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Brittany Smith Company: Date Signed: Vantage Point Construction, Inc. 2014-10-23 10:16:25 Address: License: 42-240 Green Way, Ste B 473996 City/State/Zip: Phone: Palm Desert, CA 92211 760-340-5157 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document and in no information. CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVEDN implies Registration §TRUQTons9V.ty for DATE BY accuracy of the Registration Number: 214-A0123799A-000000000-0000 Registration Date/Time: 2014-10-23 10:16:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at 2014-30-22 14:25:27