Loading...
0204-134 (PAT)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. 'License # Lic. Class Exp. Date p Date~Signature of Contractor f �+, �' / _k, C. f � ' OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). () I am a tempt under Section B&P"C. for this reason'. t Date f f i'' f ` Signature of Owner i!"�� A f � WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: () I have and will maintain a certificate of consent.to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are:. Carrier Policy No. (This section need not be completed if the permit valuation is for $100.00 or less). (� I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of ,California, and agree that if I should become subject to the workers' compensation provisions of .Section 3700 of the Labor Code, I s all forthwith comply with thoe provisions ' + E F Date: t j 1 t Applicant 1 F`" Y_\ KA,I) Warning: Failure to secure Workers Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. . 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property for inspection purposes. ✓'Signature (Owner/Agent) J s� �f.t s� Date PERMIT # 'BUILDING PERMIT ,,,_1 DATE � .fi i r, VALUATION "• 7 , q ..LOT v< r�+ f TRACT 1166' V Q6 JOB SITE ADDRESS _l Tis A7 . , APN 7731�e�� OWNER CONTRACTOR/ / EN INEER Soo, 11.001noujv Ow'hillit l36"U' iffelk 54-O.'s AMTfDJ%,CAARANZA LAQ11U$N€A CA. 9_t253 .. G`YsL'it USE OF PERMIT PAM 5 2 Sid ftiTJALT L91':l?A .(0 COVIA1 I. C-rff'!3'i. A?4OA RIO. 320.00 o? ,rERMAT :QW- MMMARY KXN% CMCKF1f4.S 101-0W,4339-318 �,o .E�� S�!'I L? Imo? �014W-4184M .i' ''�,k�f�3''r�'�:�>).d':iB�� �:i�'f�&'�l:J; �SPiD•�•�H104� �.zif3 aNk 17 2002 QTVOF(A WDIOTALW STOWT10N AND PLAN - LTIM PRE-PA11).F'1c�.=�; 43.tt 41 TMAL AWRMT FRES D00, NOW RECEIPT DATE �! BYE j' DATE FINALED INSPECTOR 1b 7/'o21 �� -7.3t-02, INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck p Z Exhaust Fans O.K. to Wrap F.A.U. Framing eP7, Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wail Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final IL BLOCKWAL APPROVALS POOLS - SPAS Steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Pibg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation .as Piping Gas Test Appliances Final r' Filial Utiyty Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: RAFTER SIZE AND SPACING ( 1 IL ROO- PITCH CONTINUOUS LEDGER ' (SAME SIZE AS RAFTERS) HEADER SIZE i RAFTEP, SPAN: o.. c�) /\ J O.H. a 0 a ,fir Cl.�r � RVVr�IVV ���V V�C�`I - (SEE ROOFING NOTE ON REVERSE)_ j `-'T' AND 'L' STRAPS Gx6 x1"xl/4" WITH ( I (4) 16c NAILS O= BOLT POS" SPACING-, - O.H. LfoB OVERALL LENGTH.___ _ POST SIZE. REAR SETBACK SIDE SE78ACK (4'x4- MIN.) I 7 L . FINISH GRADE FINISH GRADE MIN1 2" x 12"� FOOTING I 2000 P.S.I CONCRETE -' I i L_J L -J 12" BELOW GRADE L -J PROVIDE 1" CLEARANCE BETWEEN POST AND CONCRETE NOTE: OPEN LATTICE PATIO COVERS MAY BE ATTACHED TO EXISTING FASCIA. VIA ONE 1/a' x 5' LAG SCREW THROUGH FASCIA INTO EACH RAFTER TAIL. BUILDING DEPARTMENT APPROVAL BELOW CITY OF LA QIJIWA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION jnATp 4 By U -STRAP OR AN( NON -CORROSIVE (4)- 16d NAILS OR BOLT U -STRAP OR ANGLE (4)- 16d NAILS OR BOLT PROVIDE 1" CLEARANCE BETWEEN POST AND CONCRETE ANCHOR BOLT (EMBED — 7" MIN. INTO CONCRETE) TYPICAL PATIO COVER DATE OF APPLICATION OWNER'S NAME STREET ADDRESS CITY, ST ZIP I TELEPHONE H.O.A. APPROVAL F lk FATTER SP^ -N TABLE ALL CONSTRUCTION SHALL CONFORM GRADING RULES PS 20-70 / �c� i vv � �� � � ,/ TO THE PROVISIONS OF THE: , (FEET & INCHES) iOJ�" OJ��/O i 1998 CALIFORNIA BUILDING CODE. =OC % SUPPLEMENTAL NOTES. I "x4 24 10'—e" 9'-6" 7'-3' 8-9" 87_6 8. _ 01.6-0" —3 FIR NO. 1 DOUGLAS FIR oxo 16" O.C. 24" ;; 32" 15'-0" 14'-0" 10'-9" 13'-0" 12'-0' 11'—b' 8'-9" 10'-6" 10-0" 8-6' N/A N A 8'-0" 4x6 _ I 16" O.C. 24" 32" 18'-0" 17'-0" 13'-6" 16'-0" 15' -ti" 14'-6" i 11'-0" 13'-0° 13'-0" 11'-6" N/A N/A 4x12 17'-0" NOTES: 1. 32" RAFTER SPACING IS ALLOWABLE FOR OPEN LATTICE PATIO COVERS ONLY. 2. FOR SOLID PATIO COVERS (NOT LATTICE) RAFTER SPAN IS LIMITED TO 10'-0" USING THIS STANDARD. LATTICE ROOF BUILT—UP ROOF HEADERS HEADERS DOUGLAS FIR NO. 1 DOUGLAS FIR NO. 1 j 5 i=E I SPAN SIZE SPAN 4;.4 5'-0" 4x4 4'-0" 4>:6 8'-0" 4x6 6'-0" =1x8 1 t'-0" 4x8 8'-0" 4':;10 it' -0" 400 10'-0" 4x12 17'-0" 4x12 12'-0" 6x8 14'-0" 6x8 12'-0" 600 17'-0" 6x 10 14'-0" ROOFING NOTES: A. BUILT—UP, ROLLED ROOF: SLOPE TO DRAIN. Q Onf'L' DnnC'. z 1I -) hAAYthAI IAA OlTrlLj