Loading...
9805-049 (SFD)N LL1 C) M r,LL� rZ tY o Z (.DOo J V wr- LU F- a U) Z M L0 N 0� 0 Q o � r�Lo0 0 J J mUU O a ,It Z_ ob n 0 J 61 LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date C'4HC 12131/Ofs Date Signature of Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the'property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). f (,,)ll am exempt under Section - , B&P.C. for this reason ,/Date 47t/Signature of Owner �� .�• .. WORKER'S COMPENSATION DECLARATION I hereby affirm- under penalty of perjury one of the following. declarations: ( ) I have and will maintain a certificate of, consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.. (I have and will maintain workers' compensation insurance, as required by Se4iion 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier Policy No. TRUCK 114;X&its3IC113.1 A20)"43W 0.0 tra (This section need. not be completed if the permit valuation is for $100.00 or less)., () I certify that in the performance of the work for which this permit is, issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become ' subjlt to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with tho a rovisions. /6ate: � Applicant— Warni g: ilure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in, addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property for inspection purposes. /ignature (Owner/Agent) 22Date BUILDING PERMIT PERMIT9Nt'.5-049 CONTROLH DATE / VALUATION $77,641.70 LOT 22 TRACT 1 -750 -ADDRESS JOB SIT . El 5J. -S40 AVENIDA CAMtktNZi APN x'73- i2:i �ti3 OWNER CONTRACTOR / DESIGNER / ENGINEER Ad`lIGIS1., ;43,r;R iR " rrM C "'-f:. INDIO CA 9220t (7601241.7-3 t 57 CBL# USE OF PERMIT Sp. b 317U - 0 Tai-D#2uufirij PFIRI IT om NOT i1 c frci BI OCC WALLS ok ,P0rJ . PLI•\.t'+i <tTCh'OiTICYV O F' .! E1.3S REI)i)C0) 75%) Oft'MUL'1.'wI..i; ISSUANCE OF SANT-13 FLAN ` YPIE , LJ MAY 14 1998 CvEt€tAOFiiC:nit3aC�f2`i' S2�,.(k1il? _ p oin41 A L 0,11:01 i i'4 1 ENTINLA "EM CGST der', CONS'A RUMON 77,640670 P ERN1.1.8 l+RESURrS-1'�'�ARY (c,N6r 1kU(1_i'KYN FEE i 1�I�4}(tC} X11 k� (3!10 xs>1rJ.S0 pr,1-�J- t 0 l,-#)tt().n3g_zr#3 $114 (i IQ14)00-R?100 $40-110 "u,i;`,1'd{2t'iki. T 101-00-420-000 si 16. is t t'f:iA9i 11lEcro .1 `i li; i.:{.-43f�J-4l.-f3th� $;`2 i .St? !ti'tiq?fCdl19i:7rilowri,Fr 1m%w). 1()i, -M -241-11,1(N) $7.76 f,'Ct�113I3'401'lr'. 32000 07Jf tA:.TR.ifCTl JtrC VCR 25-t°ti3%%-443-342. $1, J.t6.39 7�!t(it iwi .4>.l..ftfd k,0140W441-345 $25.09 SUR-ITYPAY, CCW,, '1',R_UCT10N AND PLAN CARE, 2,_1M7 7-1 LESS PRE -PAID 1IECkS $0 GVJ ti �(7 RECEIPT DATE BY DATE FINALED INSPECTOR INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS ` Set Backs `p Underground Ducts Forms 8 Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans OX to Wrapo2 - F.A.U. Framing 9 ,/2 Q Compressor .L. - Int. Lath BLOCKWALL APPROVALS Set Backs Footings Bond Beam Final PLUMBING APPROVALS Waste Lines Water Piping Plumbing Top Out Shower Pans Sewer Lateral Sewer Connection _9 Gas Piping FIG., Gas Test -,99 Utility Notice (Gas) j2' e -r ELECTRICAL APPROVALS Temp. Power Pole Underaround Conduit Steel Electric Bond Main Drain Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Gas Piping Gas Test Electric Final Heater Final Plumbing Final Equipment Enclosure O.K. for Finish Plaster Pool Cover COMMENTS: e d C Low Voltage Wiring Fixtures Main Service Sub Panels - , ,Eidedor Receptacles - G.F.I. ' Smoke Detectors . Temp. Use of Power Final �'• :.; - UbUty Notice (Perm) Steel Electric Bond Main Drain Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Gas Piping Gas Test Electric Final Heater Final Plumbing Final Equipment Enclosure O.K. for Finish Plaster Pool Cover COMMENTS: e d C cocoon THIS ATTIC HAS BEEN INSULATED T0: R- 0 This attic has been insulated to the R -value indicated above, with Cocoon" the high -efficiency insulation. Made from a minimum of 80% recycled materials, Cocoon is scientifically formulated to deliver greater efficiency per inch than other insulation materials. R -value is a measure of resistance to heat flow - the higher the R -value, the greater the insulating power. If you would like to add more insulation to your home, contact your Cocoon authorized dealer. Ecooff 11a n nfelcll?er1 131'. GREENSTONE.•:'" A LOy1FIANA.PACIFIC COMPANY NOTE: This coverage chart compensates fur settling and is fur estimating purposes only. Stated R -value is firurided by installing the n•yuired numhyr of hags per IWMI sq. ft. at a minimum installed thickness. Installation of the required nundnr of Ixlgs mal' yield more than the specified minimum thickness and minimum weight per sq. ft. Actual eo%erage will be influenced by job conditions and application techniques, and may van' as inuch as 100) without significantly affecting the stated R-ralue. Failure of the installer to provide at least the required number of bags per 1000 a1. ft. and at least the minimum thickness may result in a lower installed R -value. Compaction may occur during installations above R-30. requiring more than the stated number of bags to obtain the minimum installed thickness. GreenStone and Cocoon are trademarks of GreenStone, a Louisiana-Pacific company. (D 1997 GreenStone Industries, Inc. All rights reserved. Printed in USA. RV 30M 8/97. B-97-TT/G-A RESIDENCE ADDRESS: & as 7t I S L -o PWC (_r0- n z� LvA- ��� - Z -Z 53 INSTALLED BY $* 17 7 I n 1'e'a n may' L)Ln 1r c'3 di 1*1, ";1 ZZo 1 BUILDER: G V H �S "7 0 ► YYl a n Aro � 5�- Ea CERTIFICATION: This is to certify that attic -insulation has been installed in conformance with the coverage chart recommenda- tions on the opposite side of this card using 140 bags to coverl06 If sq. ft. to obtain an 11 -value of -319 . Iq q INSTA ER'S UTHORIZED SIGNATURE DATE Cocoon Stabilized Insulation 30 lb. bag ATOMIZED PNEUMATIC APPLICATION COVERAGE CHART 51.4 19.4 Net Coverage No Adjustment for Trusses - 56.7 R -Value at Minimum 5.5 Gross Coverage Based on 751 Mean Temperature Thickness 2'x 6' Trusses on 16' Centers Maximum Net Minimum Weight Coverage Per Square Foot The Weight Per Installed Square foot of Baps Required To Obtain an Insulation Square Feet Minimum Bags Installed Square Feet Per 1.000 Insulation Should Not Be Per Bag Required Per Insulation Per Bag Square Feet Resistance (R) of: Less Than: 1,000 Square Feet Should Not Be (inches) Less Than: (lbs.) R-50 13.5 20.5. 48.8 1.464 21.3 46.9 R-42 11.4 24.4 41.0 1.230 25.6 39.1 R-40 10.8 25.6 39.0 1.171 26.9 37.2 R-38 10.3 27.0 37.1 1.113 28.4 35.2 R-32 8.6 32.0 31.2 .937 34.0 29.4 R-30 8.1 34.2 29.3 .878 36.5 27.4 R-24 6.5 42.7 23.4 .703 46.4 21.6 R-22 5.9 46.6 21.5 .644 51.0 19.6 R-19 5.1 53.9 18.5 .556 59.5 16.8 R-13 3.5 78.8 12.7 .381 87.0 11.5 R-11 3.0 93.1 10.7 .322 102.8 9.7 Ctidamallc Insecure filled-rlansity 20 PPCFI R-13 (2 x 4) 3.5 51.4 19.4 .583 56.7 17.6 R-20 (2 x 6) 5.5 323 30.6 .917 36.1 27.7 4 4 " P.O. BOX 1504 APPLICATION ONLY 1' �y,� , /�' 78-495 CALLE TAMPICO Address ��yD �V/ G� fL�QI�'v v� LA oUINTA, CALIFORNIA 92253 6EZ � /1) 6 n 17 IV kS�g &74 9 /7'J Address , City Zip Tel. Contractor D( &6"k 6(.4/G1P2 Zip State Lic.I City & Classif. Lic. # Designer .09 e9fmS Z)Z--SJ (W Address I Tel. CityI Zip I State LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License law for the following reason: (Sec. 7031.5. Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to 'Its issuance also requires the applicant for such permit to rile a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code. or that -he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than rive hundred dollars ($500). Cl 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building orimprovement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) I'I 1, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) 17 1 am exempt under Sec. B. & P.C. for this reason /rt-' �'-r•�uar � �� WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy *,hereof. (Sec. 3800, Labor Code.) Policy No. Company (7 Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed If the permit Is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work for which this permit is issued, 1 shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that 1 have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above- mentioned property for inspection purposes. ILDING: TYPE'CONST. OCC. GRP. Number 7-7 3:j- 2S— yo3 Description t DescriptionJf'Tq�n11 I}�Gcr�N f -Q Sq. Ft. Size /2/5- /S New is Add ❑ tstlmateo valuation No. No. Dw. Stories Units Alter ❑ Repair ❑ Demolition ❑ PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line FINAL DATE Side Setback from Property Line INSPECTOR Issued by: Date Permit Validated by: Signature of applicant —Date— Mailing ateMailing Address Validation: City, State, Zip WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING DIVISION Desert Sands Unified School District Notice: 82-879 Highway 111 Document Cannot Be Duplicated Indio, CA 92201 619-775-3500 CERTIFICATE OF COMPLIANCE Date 5/13/98 No. 17025 Owner NameAngel Martin Escobedo Martinez No. 51-540 Street Avenida Carranza City La Quinta Tract # Lot # Type of Development Single Family Residence Comments APN # 773-125-003 Jurisdiction La Quinta Permit # Log # zip 92253 Study Area Square Footage 1,215 No. of Units 1 At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that.school facility fees imposed pursuant to Government Code 53080 in the amount of 1.93 X 1,215 or $ 2,344.95 the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may iiow be issued Fees Paid By Cashier Check/Bank of America/Bill StandeferTeLNhdne `, Name on the check ' ' . ��_ ✓, ti ti q �.. By Dr. Doris Wilson y Superintendent L Fee collected /exempted by Juanita Green Payment Received $2,3445.95 Check No. 2009914079 Signature NOTICE: Pursuant of AsMrnbty Bill 3081 (CHAP 549, STATS. 1996) this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is sssued or on which they are paid to the District(s) or to another public entity authorized to tolled them on the District('s)(s') behalf, whichever is earlier. Collector: Attach a copy of county or city plan check application form to district copy for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting Coachella Valley Housing Coalition • Plaza 1, 45-701 Monroe Street, Suite G., Indio, CA 92201 TEL: (760) 347-3157 FAX: (760) 342-6466 Tat ATTORNEY-IN-FACT AGREEMENT I/We hereby appoint COACHELLA VALLEY HOUSING COALITION, and/or any of its authorized agents as my/our attorney -in fact for the purpose of executing any notices of completion, waiver, of liens and/or executing contracts with subcontractors, and/or release of liens and/or handling building permits relating to that certain real property described below. All that certain land located and being in the County of Riverside, State of California, described as follows: LOT 22 OF BLOCK 55 OF UNIT 5 OF SANTA CARMELITA AT VALE LA QUINTA, AS SHOWN BY MAP RECORDED IN BOOK 18, PAGE 63 OF MAPS, RIVERSIDE COUNTY RECORDS. -4161q8 Date 4-6-gb Date f:\sfamily\an na\miscfor\attnyfa Angel Martin Escobedo Martinez Monica Guajardo May 5. 1998 Mr. Daniel Crawford -Inspector City. of La Quinta Department of Building and Safety 78-495 Callc Tampico La Quinta. California 92253 ftardinb: C1,71C Plan 320 and 420 - Truss; Calculations Dear Daniel: STRUCTURAL ENGINEERING CONSULTANT 54-625 AVENIDA BERMUDAS. LA QUINTA CALIFORNIA 92253 760.564.0884 PHON E tr 760.771.3606 FAX to W) S H@ C W lit 4.M nr.. mom .n rr:kOic�Ess'` 0vOM me 0/1M �p I have reviewed the truss calculations from Imperial Roof Truss which is to be used for the roof construction of the 3 bedroom and 4 bedroom hones in La Quinta. The truss calculations labeled "320 Plan" an for the 3 bedroom plan that is associated to the "96-051" job number listed in the lower right corner of the architectural plans. The "420 Plan" taus calculations correspond to the "964)52" 4 bedroom drawings. I have reviewed the truss calculations to coniine the capicily of all design loads drags and bottom chord loaded girder trusses. 1 have found each to be in compliance with the intentions of the structural design. I have also verified that the roof dead loads used in the design of the trusses exceed the design loads on the structural calculations. The truss calculations arc more conservative and therefore acceptable. The Truss calculations will be used for the following addresses of the self-help La Quinta Group 4 Construction. - 51 -865 onstruction:51-865 Ave. Ramirez AP#773-165-018 -Lot 6 Plan 420 51-885 Ave. Ramirez AP#773-165-019 - Lot 7 Plan 320 51-905 Ave. Ramirez AP#773-165-020 - Lot 8 Plan 420 51-945 Ave. Ramirez AP#773-165-022 - Lot 1.0 Plan 320 51-680 Ave. Carranza AP#773-125-009 - Lot 16 Plan 420 5I -656 Avc..RamiTcz AP#773-1 :T 1-008 - Lot 17 Plan 320 51-660 Ave. Ramirez AP#773-125-008 - Lot 17 Plan 320 51-560 Ave. Carranza AP#773-125-004 - Lot 21 Plan 320 51-540 Ave. Carranza AP#773-125-003 -Lot 22 Plan 320 51-790 Ave. Carranza AP#773-165-003 - Lot 22 Plan 420 Please contact me at your earliest corn-enience if you should have any questions or additional requirements. Sincerely, Dennis S. Wish PE Structural Engineering Consultant STRUCTURAL ENiINFERINC FOR - CUSTMI HDIAES - RETAODEL -COMMERCIAL - LIGHT INDUSTRIAL -SEISMIC RETROFIT & REPAIR - UNROWORCED MASONRY- RETAINNG WALLS & FOV IDATION - REPORTS: DAMAGE ASSESSMENT - NEW ROOF - INSURANCE CLAIM-DENNIS S. WISH P E HAS BEEN A MEMBER OF THE STRUCTURALEPIGNEERS ASSOCIATION OF SOUTHERN CALIFORNIA SPICE 1983 Dennl'5 5 Wish PE Structural Engineering Consultant 54-625 Avenida Bermudas La Quinta, California 92253 760.564.0884 Phone 760.771.3606 Fax Email: wish@cwia.com CLIENT Coachella Valley Housing Coalition Job No 9806 PROJECT La Quinta Plan 51 & 52 - Redesign SHEET 1 OF CALCULATION DESCRIPTION: Redesign of lateral analysis for metal stud homes DESIGN LOADS ROOF LOADS: DESIGN WIND VELOCITY = TILE ROOFING = 10.0 PSF 112" SHEATHING = 1.5 PSF TRUSS FRAMING = 2.0 PSF 5/8" GYPSUM BD. CEILING = 2.8 PSF INSULATION = 0.5 PSF MECH, ELEC & SPRINKLERS = 1.0 PSF SUB -TOTAL, = 17.8 PSF SLOPE CORRECTION 1/3 1.05 PSF MISCELLANEOUS = 1.1 PSF ROOF DEAD LOAD : = 20.0 PSF ROOF SNOW LOAD : = 0.0 PSF ROOF LIVE LOAD : = 16.0 PSF EXTERIOR WALL LOADS: DESIGN WIND VELOCITY = 7/8" STUCCO = 12.5 PSF 15/32" SHEATHING = 1.4 PSF 2X6@16" O/C = 1.5 PSF R19 INSULATION = 0.5 PSF 1/2" GYPSUM BD. = 2.2 PSF MISCELLANEOUS = 1.9 PSF TOTAL EXTERIOR WALL = 20.0 PSF SOILS DATA: SOILS REPORT BY: REPORT DATE: BASIC BEARING PRESSURE PADS & CONT. FNDT. = Qa INCREASE FOR WIDTH INCREASE FOR DEPTH MAX. SOIL PRESSURE - Qa FLOOR LOADS: DESIGN WIND VELOCITY = FLOOR FINISH = 0.0 PSF 3/4" SHEATHING = 0.0 PSF 2X OR TRUSS FRAMING = G.0 PSF 5/8" GYPSUM BD. CEILING = 0.0 PSF PARTITION LOADS = 0.0 PSF MECH, ELEC & SPRIINKLERS = 0 0 PSF MISCELLANEOUS - 0.0 PSF FLOOR DEAD LOAD : = 0.0 PSF FLOOR LIVE LOAD : = 40.0 PSF INTERIOR WALL LOADS: 1/2" GYPSUM BO. (B.S.) = 4.4 PSF 15/32" SHEATHING = 1.4 PSF 2X4 @ 16" O/C = 1.0 PSF MISCELLANEOUS = 2.7 PSF TOTAL INTERIOR WALL : = 9.5 PSF UBC DEFAULT VALUES - REPORT NOT APP 1.500 PSF ALLOWABLE PRESSURE 20.0 % PER FT. GREATER THAN V-0" 20.0 % PER FT.+GREATER THAN 1'-0" = 4,500.0 PSF ALLOW PASSIVE PRESSURE = 0.0 PCF ALLOW SOIL FRICTION = 0.3 WIND LOADS: DESIGN WIND VELOCITY = 70.0 MPH qs = 12.6 PSF C - h<15 Ft. = 1.06 Cs -15 Ft.<h<20Ft. = 1.13 Cs -20 Ft.< h< 25 Ft. = 1.19 Cs -25 Ft,< h< 30 Ft. = 1.23 SEISMIC LOADS: ZONE _ IMPORTANCE FACTOR = Rw = ZIC/Rw = 0.4"2.75"1/Rw = i r IMPORTANCE FACTOR = EXPOSURE D C - h<15 Ft. 1.39 Cs -15 Ft.< h< 20 Ft. 1.45 Cs -20 Ft.< h< 25 Ft. 1.5 Cs -25 Ft.< h< 30 Ft. 1.54 4 1.0 6 (PLYWOOD SHEAR WALL USED THROUGHOUT) 0.183 W d 2/22/98 1 1 C B 1.06 0.62 1.13 0.67 1.19 0.72 1.23 0.76 PenWish PE j�rs5. _:•w :,1e _� _. _. : ,_ Job No.: 9806 Engineer: DSW Date: 2/22/91 - _ .. --•--u• "' Job Title: plan 51 & 52 Checked: DSW Time: 18:47 Eas= tc Vlles# Residence and Garaqe Shearwall Spacing (ft 1 AND 13.00 2 2.5 AND 6.00 3 AND 3.0 AND 13.00 4 - - - - - Building Geometry Plate to Plate Height (ft) 8.0 6.8 53.2 1.5 20 20 8.0 6.8 53.2 20 20 3.0 6.8 53.2 20 20 8.0 6.8 53.2 1.5 20 20 20 20 20 20 20 20 20 20 20 20 Top plate to peak of roor or parapet Diaphragm Depth (ft) Left Side Roof Eave (ft) Right Side Roof Eave (ft) Exterior Walt Dead Load psf) Roof Dead Load (psf) Left Cantilever Right Cantilever Diaphragm Aspect Ratio 0.24 0.11 0_15 0.24 Wind Data Ce from 0 to 15 feet - Table 16-G 1.06 1.13 12.6 1 1.3 1.06 1.13 12.6 1 1.3 1.06 1.13 12.6 1 1.3 1.06 1.13 12.6 1 1.3 1.06 1.13 12.5 1 1.3 1.06 1.13 12.6 1 1 3 1 Ao' 1.13 12.6 1 1.3 1.)6 1.13 i 2.6 1 1 )5 1. , . 12.5-. 1 Ce from 15 to 20 feet - Table 16-G Basic Wind pressure qs (psf) - Table 16-F Occupancy Category -Table 16-K Cq - Pressure Coefficient - Table 16-H Seismic Data Z - Zone Factor - Table 164 0.4 1 2.75 6 0.4 1 2.75 6 0.4 1 2.75 6 0.4 1 2.75 6 0.s 1 2.75 6 0.4 1 2.75 6 0.4 1 2.75 66 0.4 1 2.75 0.1 1 2.75 6 I- Occupancy Category - Table 16-K C - Numerical coefficient specified in Section 1628.2.1 Rw - Structural Systems - Table 16-N F=(ZIC/Rw)Wd 0.183 0.183 0.183 0.183 0.183 0.183 0.183 0.183 0.183 Wind / Seismic Comparison Wind Pressure (plf) 188 188 188 188 Seismic Force (plf) 224 224 224 224 Governing Force 1 224 224 224 224 Governing Force Seis Seis Seis Seis Wind Wind Wind Wind Wind Diaphragm Chord - Tension Chord Tension MI /8b (lbs) 89 19- 34 89 Code Allow (1 Ed @ 16" ox.lbs 1066 492 656 1066 Additional 16d Box Nails Req'd 4 Grid ocation 1 2 2.5 3 1 4 V Shear at Grid Line #(pounds) 147L_j 2131 1570 2370 1458 v iaphragm Shear p 28 40 30 45 27 Shear Walls Length of Wall #1 Length of Wall #2 Length of Wall #3 Length of Wall #4 Length of Wall #5 Refer to attached shearwall analysis. Reference wall by Column/Cirid and Wall Number (ie,V41112 - grid 1 wall 2) 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Length of Wall #6 Length of Wall #7 Length of Wall #8 Length of Wall #9 Length of Wall #10 E Shearwall Lengths ft 12 16 8 8 12 Iv Unit 5hear (pit) 123 133 196 1 296 122 CVHC Lots 51 8 52 worst case.xls DenT71*5 5. IlVi5h PE r + A B AND AND Shearwall Spacing (ft 10.50 18.50 C AND 20.00 D .,---1^�'--'*=.,+�`'�•'.... : '_-. � . .i ,- .. ,..,-�; ww'"i' ...... - y. .:-i. ..- a..�j]7+..:].:.. x�,..:.�a..:_n ...»ascr-tij} Job No.: 9806 Engineer: DSW Date: 2/22191 Plate to Plate Height (ft) 8.0 8.0 5.8 5.8 40,0 40.0 1.5 20 20 20 20 8.0 5.8 40.0 20 20 1.5 20 20 20 20 3.0 5.8 2'1.3 1.5 20 20 Job Title: plan 51 & 52 Checked: DSW Time: 18:41 North t;; South IA-tD RESIDENCE C -E GARAGE BLOCK A B AND AND Shearwall Spacing (ft 10.50 18.50 C AND 20.00 D AND C D AND 24.33 Building Geometry Plate to Plate Height (ft) 8.0 8.0 5.8 5.8 40,0 40.0 1.5 20 20 20 20 8.0 5.8 40.0 20 20 1.5 20 20 20 20 3.0 5.8 2'1.3 1.5 20 20 20 2020 20 _3 20 Top plate to peak of root ft) Diaphragm Depth (ft) Left Side Roof Eave (ft) Right Side Roof Eave (ft) Exterior Wall Dead Load (psf) Roof Dead Load (psf) Left Cantilever Right Cantilever iap ragm spect atio 0.3 0.5 0.5 1.1 Wind Data Ce from 0 to 15 feet - Table 16-G 1.06 1.06 1.13 1.13 12.6 12.6 1 1.3 1.3 1.05 1A3 12.6 11.3 1.06 1.13 12.6 1.3 1.06 1.13 12.6 1.3 1.06 1.13 12.5 1.3 1,06 1.1 12.5 1 3 1.06 1.13 12.5 1.3 OG 2.6 1 11 Ce from 15 to 20 feet - Table 16-G • Basic Wind pressure qs (psf) - Table 16-F Occupancy Category - Table 16-K Cq - Pressure Coefficient - Table 16-H Seismic Data Z - Zone Factor - Table 16-1 0.40 0.40 1 1t 2.75 2.75 6 6 0.40 2.75 6 0.40 t 2.75 6 0.40 t 2.75 6 0.40 1 2.75 6 0.:0 2.75 6 0.40 t 2.75 ; 3.10 2.'5; 5 I- Occupancy Category - Table 16-K C - Numerical coefficient specified in Section 1628.2.1 Rw - Structural Systems - Table 16-N F=(Z!C/Rw)Wd 0.183'• 0.183 0.183 0.183 0.183 0.183 0.183 0.183. 0.183 Wind / Seismic Comparison k �w Wind Pressure (plf) 171 at , -:zs- 171- 171 1715 Seismic Force (pit) 176": • x176 176 108 Governing Force (pin 1767 176 174 Governing Force Seis-;..,'Seis Seis Wind Wind Wind. Wind Wind Wind Diaphragm Chord - Tension Chord Tension ML /8b (lbs) 6T. `;-, a`=-188 -' 220 592 �r ' Code Allow (16d Q 16" o.c.) lbs 861a :. - 1617 .1640 f.F 1995 Additional 16d 13OX Nails eq'd Grid Column Location A B C O V Shear at Grid Line #ounds 935; • r 2552 3388 1 =1760 1 2076 2076 s v lap ragm S ear (P,) ..23k i<.•�'? 64 85 --�> 44 •' • 97F 1 97 °.• Shear WallsReferto Length of Wall #1 Length of Wall #2 _ Length of Wall #3 Length of Wall #4 Length of Wall #6 Length of Wall #b71 Length of Wall #7... Length of Wall #8 Length of Wall #9 -' Length of Wall #10 attached shearwall analysis. Reference All by CotumnrGM and Watt Number (% Wa1112 - grid 1 wall 2) 4.0 3.5 8.0 4.0 8.0 2.7 4.0 3.5 8.0 4.0 8.0 2.7 4.0 4.0 2 E Shearwall Lengths (ft 16: . sa a--• 7, - 16 -8 8 ' 1. 16, 1 5 v units ear (pit) 58. 365 212 -220' 130 1 389 CVHC Lots 51 & 52 worst case.xls Shear Wall Number 1 2 3 4 5 6 7 8 9 10 Grid Line (Direction / Column Line) i 0 1 %;letai 81010 8..0 8.00 4 67 3.67 4.00 1 00 20 20 , 13 On _ .5 1 G _ iNyletai 8.00 8.00 8.00 25.00 29.00 4.00 1.00 20 20 123 u0 1.001 1 NI -a! 8 CC 8. a CO 4 c ' 8 53.' 3 4.00 1 00 20 20 123 _ _ 2.G 0 2.0 1 2 :; Metal �Ietal •:1eia1 8 00 8 GO 800 8.00 8.00 8.00 8.00 8 GO Boo Shear:ratl :niorma:,cn 12.90 2 90 13 'GO 12 90 ^.2 90 13 00 4. S7 13 50 43 18 8.67 17 50 4; 18 4.00 4.00 4.00 1.00 1.00 1.00 20 20 20 20 20 20 133.00 33 00 133.0.0 6.25 5..0 1.00 2.0 '.1etal 3 C3 3.^_C 8 00 1 O 13 r- IJ a -, ' 8 53 "3 4.00 1 :0 20 20 330, 1 �� 2 5 1 Vc-tal 8.00 3.00 8.00 18 '.3 1883 4.00 4.00 1.00 20 20 '96 00 • 1 00 2.5 Me-,ai 8 8..10 8 00 1 ° 01 ',1 18 •., 13 5;3 ; % ._ 4.00 1 n^ 20 20 1-, -- �^ 0 Vetal 00 3 JO 3 00 ?0 :0 :C 18 ---'.18 4.00 �0 -0 =0 __„ 00 00 Wall Section at Grid Line Framing (Metal or Wood) Height to lateral Load or Drag_ Lateral Unb_raced Height Plate to Plate Height Note: Origin in lower left corner Start X�oordinate " End X - Coordinate Start Y -coordinate End Y - Coordinate Shearwall Width Governing Force - Enter 0.85 for Seismic and 1.0 for Wind Roof Dead Load (RDL) plf Exterior Wall Dead Load (WDL) - plf Applied Lateral Load (vltin plfr Replacement or additional Drag load (Ibs) Roof or Floor Tributary Area to resist uplift in feet Applied load for header at left of shearwall in pounds Applied load for header at right of shearwall in pounds Shearwall Ratio 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 Total Lateral + Drag (plf) 123 123 123 133 133 133 133 196 196 296 Weight of Shearwall in pounds 640 640 640 640 640 640 640 640 640 640 Weigh of Roof/Floor above wall in plf 125 20 20 125 125 20 20 220 220 20 L- Overturning Moment - ft -kips 7 7 7 7 7 7 7 10 10 15 J=_ Resisting Moment at Right Side of Wall in kis 2 1 1 2 2. 1 1 3 3 1 Resisting Moment at Left Side of Wall in kis 2 1 1 2 1 1 3 3 1 - - _ t *' .'l .r> .G- ,.�..---L:._ -=err^--.-.•ate. _ ._ f :�_ �-'�'^"-�'. �+-'_ �.;:� f 'r`a+_� ?+�.� __ ;--�"i'�: r _ _ _ _ ...Fr '�.'`'-. Is HD at Corner? 1=Yes O=N; 1 PA 0 PA 0 PA 1 PA 0 PA 1 PA 0 PA 1 PA 1 PA 1 HD Enter Simpson HD, PA or FTM Uplift at Right side of wall in lbs 1,270 1516 1516 1410 1410 1 1656 1 1656 1 2073 2073 3946 Holddown Required HPAH022- PAHD42- - [PAHD42 IHDZAr IPAHD42 I HD2A IPAHD42 jHD2A HD2A H06A Is HD at Corner? 1=Yes O=No 0 PA 0 PA 1 PA 0 PA 0 PA 0 PA 1 PA 0 PA 1 PA 1 HD Enter Simpson HD, PA or FTM Uplift at Left side of wall in Ibs 1,270 1516 1 1516 1 1410 1 1410 1 1656 1 1656 1 2073 2073 1 3946 Holddown Required PAHD42 IPAHD42 jHD2A IPAHD42 IPAHD42 IPAHD42 11,02A IPAHD42 11,1132A jHD6A Soleplate Thickness (actual - in.) 1.5 1/2 1.5 1/2 1.5 1/2 1.5 1/2 1.5 1/2 1.5 1/2 1.5 1/2 1.5 1/2 1.5 1/2 1.5 1/2 Diameter of Anchor Bolt (in.) Capacity per bolt in pounds 1,265 1,265 1,265 1,265 1,265 1,265 1,265 1,265 1,265 1,265 Total Base Shear of Wall (Ibs) . 611 611 611 651 651 651 651 903 903 1,303 Spacing of Bolts in Inches 48 48 48 48 48 48 48 48 48 42 Min Number required 2 2 2 2 2 2 2 2 2 2 f x,.t: - C` ' 3 r K = n,.J. '� 4S' ice. -_ ....^ L .t..-• .i �]�t^7.�'Ct.S ,' t .A: 'F 7 .. .. _.. _ ..__ _�_ _ ...., _•__ - ...2.2.22 ._�:_ .. _•_. _ _. _.... � j:.. _ ,_ ._. -'Z---'.-.;11 __...,_ .... Shear Wall Number 11 12 13 14 15 16 17 18 19 20 Grid Line (Direction / Column Line) 3.0 4.0 1 Metal 1`Aetal 3.00 S.00 8.00 8.00 8.00 8.00 27.00 40.00 27.00 41000 49.18 53.18 4.00 4.00 4.00 1.00 1.00 20 20 20 20 296.00 122.00 1.00 1?.00 4.0 2 Nletal 8.00 8.00 8.00 40.00 40.00 22.50 26.50 4.00 1,00 20 20 122.00 1.00 4.0 A A A 3 2 Metal r•Aetal Metal Metal 8.00 3,00 8.00 8.00 8.00 a. CIO 8.00 3.:;0 8.00 8.00 8.00 8.00 Shear•,,.aII Plot intormat;on 40.00 9.00 27.00 40.00 4.:?0 13 GG ;1 00 49.18 53. i 8 53.18 53.18 53.18 53 18 53.13 53 18 4.00 4.00 4.00 4.00 1.00 1.00 0.85 0.35 20 20 ?0 20 20 20 20 20 122 0G C C0 58.00 58.00 1.00 00 1u,00 '-' 00 A Nletai 3.00 8.00 5.00 36.00 4000 53.18 53.1843.1= 4.00 0.85 20 20 58.00 14.00 B 'Aetai 8.00 8.O0 3.00 13. C•0 43 1 c 3.50 0.8E 20 20 365 . _ �.0 S Metal 8.00 8.00 8.00 23.50 27 00 413.18 43.18 3.50 0.85 20 20 365.00 9.00 Wall Section at Grid Gine'_ Framing (Metal or Wood) Height to lateral Load or Drag Lateral Unbraced Height Plate to Plate Height Note: Origin in lower leff corner Start _X-coordinate End X -Coordinate. Start Y -coordinate End Y - Coordinate Shearwall Width Governing Force - Enter 0.85 for Seismic and 1.0 for Wind. Roof Dead Load (RDL) plf Exterior Wall Dead Load (WDL) - plf Applied Lateral Load (vl,, in plf) Replacement or additional Drag. load Ibs) Roof or Floor Tributary Area to resist uplift in feet Applied load for header at left of shearwall in pounds Applied load for header at right of shearwall in pounds,' Shearwall Ratio ;; 2.00; >, 2.0V: =2.00 X2.00 2.00;.x, ' 2.00 2.00 2.00. 2.29 2.29:?, - Total Lateral + Drag (pM - ' 296"- '° '122..x. vi122 ". X122 58 58 ;- 58 58 . "= 365 365 Weight of Shearwall in pounds 640s�• 640;1;;- -.,,640 ` 11,�640 640 '_ 640 640- . 640,.:' 560 560 �Weigh of Roof/Floor above wall in �r 20 u 220 ` -20 e, ° 20 �' 280 & ^. 280 280 280 180 180 $zY -= - - - a - R, R _T4 r-i_� -Y:k tet_ •. •^iTiM-�� a-�:--s----jF.-- .'.r-- L_ £-ii -Y ry+rr'FM Overturning Moment- *ips 15z.n t. ,.7 4 7 .3• `r.7A 3 2 2, „21,ri 11 <1.1 .`..T -[�--Lz`i..Fi4'�n�-i-_•M3 ji.=,. T_.' }�'?9'- Resisting{Moent at Right Side m of Wall in kis h , 1 '; g, 3' 1 : ? t: 4 ; x"7.3 SwF 3 2 ` `� 2­ Resisting Moment at Left Side of Wall in kiss F. 1 :` y ? 3 _Y'".1 '�' • v:r51 4 W< :sz 3 r s 3 '' 4� 3 22' :.:N; :ice �vc„•-u --^, � - �. rc-_a>?��- ''^x •'� z"'F.X �.. >�_- - �, �� ,-L3 .. ..:. _ . _. .[ s . vf:t.s,isf•Y.-.."." ... ..... mr,ri'en- " ''tifY Is HD at Corner? 1=Yes O=No'' 1 1 HO HD 1 HD 1 HD 1 1 1 HD HD HD 1 HD 1 HD 1 HO Enter Simpson HD, PA°or FTM Uplift at Right side of-waU'in'Ibs - 3946 -.1033" ,1507 1507.- •- 3040 1 '3040, Holddown Required ` :?`. HD5XX HD2A i HD2A %I HD2A';-7None"' None , None ti^ None; ,;.kl,' HD5A' HDSA°�" Is HD at Corner? 1=Yes_O=Wa' '.. ' 1 1 1 1 HD HD HD HD _. .. P?i,�f•• .:.,�.............�., ;; 3946 R 1033 • ,1502 ,1502=. 1 1 1 HD HD HD 1w.. r•n W r� .ice '=r :: �._ 1 HD _ ✓ i�� �,.-;; 1 HD `r.-- - 3040 1 HD ..y�:�,+....., 3040., Enter Simpson HD, PX& FTM' .k Uplift at Left side of wall in Ibs Holddown.Required %t ,.cy` HDSA',� HD2A : HDZA. { HD2AYr None > =�� None': None None HD5A HDSA - 'i': S i �.fl� !-`i-',. :,L.._..s.-.2'J'.tCi,.--- ':7rt.:n.. ;:..r�it�i. ' �- �t=-�-�T ' 1•i#it..1;•„-,... '-__.t#: 'li'^.�'--rc.:.�'-.,T't;--+.:11s«::s�'-�i�'4t`?s'�'3 :rl-.,t�f ..`-=.;i- r�' `"'�`x*-`-`���`-�-'+`- ---.T-tr`'h'�'�'? .-+ _ _-.�•� -u:F. ..c__•._:-.._- sa"'..�_5..:.+E.���.--z -rr.7r.•.::f_ a..:-1! 'ii'�.vT Soleplate :Thickness Cactual `=` in.);' 1.5 1.5 1/2 1/2 1.5 1/2 1.5 1/2 1.5 1.5 1.5 1/2 1/2 1/2 1.5 1/2 1.5 1/2 1.5 1/2 Diameter of Anchor Bolt (in.)" 4 Capacity per bott.in pounds: , >` . =.1,265::. ;1,265-..:. 1;265;`, : •.1;265•_ .y 1,265_., !"1;265 -:..1,265•• : 1;265. 1,265; Total Base Shear'of Wall (Ibs) V .1,303'•• "e -607;W' 607. 607,'•x: ' 351,. r ;'<> 351' 4, 35V'- s' 351',^ 1;382 1,382. Spacing of Bolts in -Inches--..:.- ' ::_ 42 -'.- ;:._ 48•,: x "P,48. 48 w ' r .•48:: : 48-'- - 32' : 32- s`. Min Number required w ..„ ......: �:2• .. i2ya> 2 f°%• 2' 2. ?.,2. ;2. d ,2 5oleplate Thickness (actual ;An.). `!. 1.5 1/2 Shear Wall Number 21 22 23 24 25 26 27 28 29 30 Grid Line (Direction I Column <1,265. .: _,120&, ,,:..1,265- -....1,265:: ,.::1,265 .1,265 1,265 1,265:.. Total Base Shear of Walt (lbs) - 1,934 Line) C ;,Metal C 2 Metal D 1 Metal D 2 !bletal E 1 !-Metal E 2 Metal Metal !Vletal i11 Nletal _ Wall Section at Grid Line Framing (Metal or Wood) Height to lateral_ Load_ or Drag 3.00 8.00 ago 18.57 26.157 24.33 24 '33 8.00 8.00 8.00 8.00 32.00 40.30 24.33 24.33 8.00 8.00 8.00 8.00 4.00 4.57 4.67 4.00 8.00 8.00 8.00 Shearriail 8.00 12.90 4.67 4.67 4.00 81,10 8.00 3.00 8.00 800 8.00 Plot Information ;8.67 37.33 21.34 40.00 2.67 2.67 8 110 8.f0 8.'3.0 #N/A 8.00 8.00 8.00 #N/A 3.00 3.0C• 8.130 #N/A Boo 8.00 8.00 #N/A Lateral Unbraced Height Plate to Plate Height Note: Origin in lower left corner Start X-coordinate End X - Coordinate Start Y -coordinate End Y - Coordinate Shearwall Width Governing Force - Enter 0.85 for Seismic and 1.0 for Wind. 0.85 20 0.85 20 0.35 20 0.85 20 0.85 20 0.85 20 0.85 20 0.85 20 0.85 20 0.85 20 Roof Dead Load (RDL) plf Exterior Wall Dead Load (WDL) - plf 20 212.00 20 212.00 20 20 ''_0 00 220.00 20 389.00 20 389.00 20 20 20 20 Applied Lateral Load (vj, in plf) Replacement or additional Drag- ragload load(lbs) Roof or Floor Tributary Area to resist uplift in feet 4.00 14.00 1.00 1.00 1.00 1.00 -1.33 1.00 1.r.(` 1.00 Applied load for header at left of shearwall in pounds Applied load for header at right of shearwall in pounds Shearwall Ratio 1.00 ,1.00 2.00 2.00 3.00 3.00 #NIA #N/A #N/A #N/A Total Lateral + Drag (plf) 212 - 212 220 "1220 389 389' #N/A #N/A #N/A #N/A" Weight of Shearwall in pounds 1,280 1,280' 640 "''-T 40 427 427. #N/A #NIA #NIA #N/A, Weigh of Roof/Floor above wall in'". x -y ptf 280" .' %',"180'r " 20 `,&-'20 20 20 20 201 20 20 " -•-•- -�- tr -T �.` = +-L'Ts3 - .�'. r' �%._ Overturning Moment - ft -kips 15 `. ,J5f- 8 8 9 � ^, 9� -� .:#N/A #N/A' #N/A #N/k - Resisting Moment at Right Side of Wall in kis 12 -"• 4,12 11,r 1.1' #N/A #N/A' #N/A #N/Au Resisting Moment at Left Side of: Wall in kis 12 12. , 1 `1 .' 1 ;r1 #N/A #N/A' #N/A #N/A i_ T .`. f .. .. -T� -�C"'+m' -. -SL : y...y fea3� �'� -..- i - ''�� y. _ LT Tjrt•iT '-� �...` Is HD at Corner? 1=Yes O=No • 1 HD 1 HD 1 HO 1 HD 1 HD 1 HD 1 HD 1 HD 1 HD 1 HD Enter Simpson HD, PA or FTM Uplift at Right side of wa(1"in lbs 344- 7 ; 344- 1842-.-:[F 84Z 3873.. :. '-3873', -- : #N/A #N/A I #N/A I #N/AY Holddown Required HD2A ..'- H02A jHl32A HDZA. ti- IH136A , H136A-N :" #NIA I #NIA'- #VIA I #NIA• Is HD at Corner7-1=Yes 0=Nd 1 1 HD HD 344 344f 1 HD -11842-.71' 1 HD -..w•.., -5. •. t1842 1 1 HD HD v '."i.. -..... ...+*-, ., 3873 3873.E 1 HD •-:. #NIA 1 HD #N/A'' 1 HD #N/A 1 _HD #NIX. Enter Simpson HD, PA or FTM Uplift at Left side of wall in Ibs Holddown:Required HD2A f ; HD2A H1132A ' HD2A'r. " HD5A HD6A -#IWA #V/A #VIA #V/A:-:' _. � .: •^..*•� _". -eiF .: _ _+: t� .�+u �-,.-.-�,,,,� �'�;`.•-��. .. .��..,--.�,----_ jay �� :-G+.. +.-e� - T [T��a.T .- �T '��F �f7'?rs!?'�• -• '_'-.. 5�� ' •TYiSF M- 5oleplate Thickness (actual ;An.). 1.5 1/2 1.5 1/2 1.5 1/2 1.5 1/2 1.5 1/2 1.5 1/2 1.5 1/2 1.5 1/2 1.5 1/2 1.5 1/2 Diameter of Anchor Bolt (in.)" Capacity per bolt in..pounds.,t >., .'.:, 1,265- _..1,265:'._ <1,265. .: _,120&, ,,:..1,265- -....1,265:: ,.::1,265 .1,265 1,265 1,265:.. Total Base Shear of Walt (lbs) - 1,934 1,934, 999 . `x,999°� 1,118 1018` #NIA #NIA #NIA #N/A Spacing of Bolts in Inches .<`, - „ 48- "-..... 48 r ' 48.. 48:.-� 32:- - 32,.. #NIA #N/A #N/A #N/A. . Min Number required .....'--Z" 2 2 2' 2 2'7-- #N/A #N/A #N/A ' #N/A NEU-Til 50 40 30 20 10 0 -10 #-o -10 I 15 16 3 � � 7 6 19 Shearwall Layout 17 18 I 11 A 114 20 n 10 21 22 �� 13 C 15 9 D 23 24 g L J 1� ,0 E 25 26 0 10 20 30 40 50 BEAMS AND HEADERS ALL BEAMS TO BE CONSTRUCTED OF DOUBLE WCJ (STEELERS) STEEL BOX BEAMS WITH FLANGE TO FLANGE CONNECTION WITH TOP AND BOTTOM TRACK AS NOTED IN STANDARD DETAIL ON SHEET D-01 EXCEPT AS INDICATED BELOW: INTERIOR NON-BEARING PARTITIONS: MAY BE CONSTRUCTED PER TYPICAL DETAIL ON SHEET D-02 FOR NON-BEARING HEADERS. BEARING HEADERS 6'-0" TO 8'-0" WIDE: MAY BE CONSTRUCTED OF WCJxl2"xl6 GAUGE Fy=50ksi BOX BEAMS. BEARING HEADERS 4'-0" TO 6'-0" WIDE: TO BE CONSTRUCTED OF WCJx8"x18 GAUGE Fy=33ksi BOX BEAMS. BEARING HEADERS LESS THAN 4'-0": TO BE CONSTRUCTED OF WCJx6"x20 GAUGE Fy=33ksi BOX BEAMS. GARAGE HEADER WITH NO GREATER THAN 5'-0" OF ROOF TRIBUTARY TO BE CONSTRUCTED OF WCJxl2"x16 GAUGE Fy=50ksi BOX BEAMS. Note: Design of headers and beams assumes a tributary load of 20'-0" plus F-0" eave with Roof Dead Load of 20 psf and Roof Live Load of 16 psf (no live load reduction used). Garage header assumes a roof tributary for design load calculations of 4'-0" + V-0" eave depth. Mmax for unpunched "J" section: Sx (gross)*Fy/1.67