14155 (SFD) Title 24-A Engineering Incorporated 1981 20th Anniversary 2001 Consulting Electrical Engineers 19031 Hlghway 18 Ste 200 72330 OuWoti Lane Apple Valley, CA 92307 Palm Desert, CA 92260 Phone: (760) 242-3369 Phone: (766Y773-4419 Fax: (760)242-1092 Fax: (76()) 242-1092 drewnjoe(dAartennet drean�ioe@aol.com S�- Ave Carrax z& /1AP'N TITLE 24, JANUARY 2001 ENERGY EFFICIENCY STANDARDS FOR LOW RISE RESIDENTIAL BUILDINGS COMPTON RESIDENCE 1,784 SQ. FT. 3/19/04 Energy Budgets for this building were determined using the CALRES VERSION 1.4 certified by the California Energy Commission. The Calres analysis attached was conducted using tables from the Residential Manual for Compliance With the Energy Efficiency Standards (for Low Rise Residential Buildings) JUNE 2001, certified by the California Energy Commission. *** HOUSE COMPLIES *** ***REFERENCE ADJUSTED ENERGY BUDGET WORKSHEET*** I hereby certify that the California Energy Commission Conservation Division regulations establishing Energy Efficiency Standards for Residential Buildings, Title -24, Part 6, have been reviewed and the design submitted substantially complies with these regulations. Joseph M. Nolan Electrical Engineer ATTACHMENTS: #1 -Adjusted Energy Budget Worksheet- Additions only #2 - CF -1 R #3 - C-2 R #4 - MF -1 R Mandatory Measures Checklist: Residential #5 - CF -6R Installation Certificate #6 - Calculation Work Sheet Existing #7 - Calculation Work Sheet - Composite CITY OF LA QUINTA #8 - FHA FORM J Heating and Cooling Calculations BUILDING & SAFETY DEPT. ft 911 Tom VY -Vkor- FOR CONSTRUCTION K:Imsoffice\WINWORDITITLE 24-COVERSIBIdg Add Typ.docTITLE 24 - RESIDENTIAL PAGE -1 Wd ADDITION PLUS EXISTING, ADJUSTED ENERGY BUDGET METHOD EXISTING COMPOSITE BUDGET USAGE BUDGET USAGE 62.98 85.51 59.28 79.18 .� 4!4W*Q1 Engineering Incorporated 1981 20th Anniversary 2001 Consulting Electrical Engineers 19031 Highway 18 Ste 200 72330'Cavyon Lane Apple Valley, CA 92307 Palm ]Desert, CA 92260 Phone: (760) 242-3369 Phone: (760) 773-4478 For: (760)2424092 Fax: (760).242-1'092 dreamjoerq�charler.net dreamjoegaol.com (ENERGY USEAGE existing +add)<\=(ENERGY BUDGET existing + add)+(FACTOR)(ENERGY USAGE existing -ENERGY BUDGET existing)) ENERGY USEAGE existing +add = EUe+a = 79.18 ENERGY BUDGET existing + add = EBe+a = 59.28 FACTOR = existing/existing+add = F = 0.89 0.89 ENERGY USAGE existing = EUe = 85.51 ENERGY Budgetexisting = Ebe = 62.98 79.18 1 < 79.34 1 »»»COMPOSITE PASSES Reference Example 7-9 pg 7-19 of the 2001 Residential Manual CERTIFICATE OF COMPLIANCE: Residential Page 1 CF -1R Project Title: COMPTON EXISTING Run: 608 18 -Mar -04 Project Address: 51-610 AVENIDA CARRANZA COMPTON EXISTING LA QUINTA Building Title: MANRIQUEZ EXISTING Building Permit # Document Author: DREAM ENGINEERING INC. (760)242-3369 Telephone: Plan Check / Date Compliance Method: CALRES2 1.4.02 Field Check / Date Climate Zone: 15 GENERAL INFORMATION Conditioned Floor Area: 1588 ft2 Exterior Conditions/Descripti Average Ceiling Height: 9'0" ft -in Yes ------------------------- Grade Building Type: SFA Single Family Detached Building Front Orientation: 270 deg (West) Glazing Area, % of Floor Area: 11.8% Fenestration Exterior Overhang Average Fenestration U-Value:0.87 (ft2) U -factor SHGC Shading Average Fenestration SHGC: 0.74 ----- 25.0 ------------ 0.87 ------------ 0.74 Number of Stories: 1 Window East 40.2' 0.87 Number of Dwelling Units: 1.00 None Window North 61.8 Floor Construction Type: Slab on grade None Window South BUILDING SHELL INSULATION 0.87 0.74 BugScrn None Cavity Sheathing Component Insul Insul Total Assembly Type R -value ------------------------------- R -value R -value -------- U -value -------- Location/Comments ----------------------- Door 0 -- 3.03 0.330 Outside Wall 13 0 11.36 0.088 Outside Wall 13 0 11.36 0.088 Outside Wall 13 0 11.36 0.088 Outside Wall 13 0 11.36 0.088 Outside Ceiling 38 0 41.67 0.024 Outside Floor, 0 0 3.38 0.295 Grade Slab Perimeter 0 0 0 0.756 Outside FLOOR TYPES AND AREAS Construction Type Area (ft2) Conditioned? Exterior Conditions/Descripti ------------------- Slab ------------ -------------- 1588 Yes ------------------------- Grade FENESTRATION Area Fenestration Fenestration Exterior Overhang Type/Orientation (ft2) U -factor SHGC Shading and Fins ----------------- Window West ----- 25.0 ------------ 0.87 ------------ 0.74 ---------- BugScrn -------- None Window East 40.2' 0.87 0.74 BugScrn None Window North 61.8 0.87 0.74 BugScrn None Window South 60.0 0.87 0.74 BugScrn None CERTIFICATE OF COMPLIANCE: Residential Page 2 CF -1R Project Title: COMPTON EXISTING Run: 608 18 -Mar -04 THERMAL MASS Area Thick Type Cover (ft2) (in) Location/Comments ----------------------- ----- ----- --------------------------------------- None HVAC SYSTEMS Refrigerant Distribution System Charge and Location Type Efficiency Airflow TXV and R -value -------------------------- ---------- ----------- ------------------- Furnace 0.78 AFUE N/A Attic R-4.2 Air cond. - central split 10.00 SEER No Attic R-4.2 HVAC DISTRIBUTION EFFICIENCY DETAILS Duct Leakage Supply Target Duct Surface ACCA Manual D (leakage cfm/ System Name Area Design % of fan cfm) Fan CFM -------------------------------------------------------------- CEC 100%R4.2 429 No n/a 1112 WATER HEATING SYSTEMS Distrib Water Water # of Energy Volume System Name Type ------------ -------- Heater Name ------------ Heater Type ----------------- Htrs ---- Factor ------ (gal) ------ Standard—Gas Standard StandardGas Storage gas 1 0.58 40 SPECIAL WATER HEATING SYSTEM CREDITS Solar savings Wood stove Wood stove System Name fraction boiler? boiler pump? ------------ ------------- ---------- ------------- Standard Gas -- No No SPECIAL WATER HEATER/BOILER DETAILS Rated Pilot Water Recovery Input Standby Tank Light Heater Name Efficiency AFUE (kBtuh) Loss R -value (Btuh) ---------------------- ------------------------- ------ StandardGas 785 -- 28.00 -- -- -- HYDRONIC DISTRIBUTION AND TERMINALS Pipe Pipe Insul Insul System/Name Type Number run (ft) diam (in) thck (in) R -value -------------- ------------- ------ -------- --------- --------- ------- None .CERTIFICATE OF COMPLIANCE: Residential Page 3 CF -1R Project Title: COMPTON EXISTING Run: 608 18 -Mar -04 SPECIAL FEATURES, REMARKS, AND NOTES 1. Heating duct register location: Ceiling. 2. Cooling duct register location: Ceiling. COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with the Energy Standards in Title 24, Parts 1 and 6, of the California Code of Regulations, and the Administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features, Remarks, and Notes section. DESIGNER OR OWNER DOCUMENTATION AUTHOR DREAM ENGINEERING INC. (760)242-3369 760-564-4447 Certification #: Ae-v Signed ENFORCEMENT AGENCY Name: Title: Signed Date COMPUTER METHOD SUMMARY Page 1 C -2R Project Title: COMPTON EXISTING Run: 608 18 -Mar -04 Project Address: 51-610 AVENIDA CARRANZA COMPTON EXISTING LA QUINTA Building Title: MANRIQUEZ EXISTING Building Permit # Document Author: DREAM ENGINEERING INC. (760)242-3369 Telephone: Plan Check / Date Compliance Method: CALRES2 1.4.02 Field Check / Date Climate Zone: 15 ENERGY USE SUMMARY (kBtu/ft2-yr) Energy Use Standard Design Space Heating 4.05 Space Cooling 43.77 Water Heating 15.16 Total Type ---------- 62.98 GENERAL INFORMATION Conditioned Floor Area: Average Ceiling Height: Building Type: Building Front Orientation: Glazing Area, % of Floor Area: Average Fenestration U -Value: Average Fenestration SHQC: Number of Dwelling Units: Number of Stories: Floor Construction Type: Number of Conditioned Zones: Total Conditioned Volume: Proposed Design --------------- 4.11 67.77 13.63 -------- Complies 85.51 No 1588 ft2 9'0" ft -in SFD Single Family Detached 270 deg (West) 11.8% 0.87 0.74 "1.00 1 Slab on grade 1 14292 ft3 BUILDING ZONE INFORMATION Floor Vent Zone Area Volume Thermostat Height Name (ft2) (ft3) Type Type (ft) HOUSE 1588 14292 Conditioned CEC Standard 2'0" OPAQUE SURFACES Surface Area U- Insl Total Tru Slr Construction Type ---------- (ft2) ------ factor ------ Rval ---- Rval ----- Azm --- Tlt --- Gns --- Type ------------ Location/Comments ------------------- Zone = HOUSE Door 20.0 0.330 0 3 270 90 Yes 30 -Wood Outside Wall 315.0 0.088 13 11 270 90 Yes W13.2x4.16 Outside Wall 496.2 0.088 13 11 0 90 Yes W13.2x4.16 Outside Wall 319.8 0.088 13 11 90 90 Yes W13.2x4.16 Outside Wall 498.0 0.088 13 11 180 90 Yes W13.2x4.16 Outside Ceiling 1588.0 0.024 38 42 -- 0 Yes R38.2x4.24 Outside Floor 1580.0 -- 0 -- -- 160 No 51abl40C Grade COMPUTER METHOD SUMMARY Page 2 C -2R Project Title: COMPTON EXISTING Run: 608 18 -Mar -04 PERIMETER LOSSES Fenestration -------------------------- Length Height Left Right Name Width Height 'H' 'V' Extension Extension ------------ ------ ------ ------ --------- --------- --------- None FINS Left Fin Right Fin Fenestration Dist Dist -------------------------- Fin Fin Ht from Fin Fin Ht from Name Height Width Depth Height 'V' fenes Depth Height 'V' fenes ------------ ------ ------ ------ ------ ----- ------ ------ ------ ----- ------ None THERMAL MASS Vol Cond- Area Thck Heat duct- Construction Insd Mass Name (ft2) (in) Cap ivity Type Rval Location/Comments -------------- ----- ---- ---- ----------------- ---- ------------------------- None SOLAR GAIN DISTRIBUTION Fenestration Winter Summer Targetted Name Fraction Fraction Thermal Mass Comments ------------ -------- -------- ------------ -------------------------------- None Insul Perimeter Length F2 Insul Depth Type ----------- (ft) -------- Factor ------ R-val ----- (in) ------ Location/Comments ---------------------------------- Zone = HOUSE Exposed 20410" 0.756 0 16 Outside FENESTRATION SURFACES Fenestration Exterior Shade Over - Fenestration Area --------------- Tru ----------------- hang Name -------------- Type ------ (ft2) U -------------- -factor SHGC ------ Azm --- Tilt ---- Type ---------- SHGC ------ /Fins ------ Zone = HOUSE FRONT Window 25.0 0.87 0.73 270 90 BugScrn 0.76 None _GLAZ BACK_GLAZ Window 40.2 0.87 0.73 90 90 BugScrn 0.76 None LEFT_GLAZ Window 61.8 0.87 0.73 0 90 BugScrn 0.76 None RIGHT GLAZ Window 60.0 0.87 0.73 180 90 BugScrn 0.76 None OVERHANGS Fenestration -------------------------- Length Height Left Right Name Width Height 'H' 'V' Extension Extension ------------ ------ ------ ------ --------- --------- --------- None FINS Left Fin Right Fin Fenestration Dist Dist -------------------------- Fin Fin Ht from Fin Fin Ht from Name Height Width Depth Height 'V' fenes Depth Height 'V' fenes ------------ ------ ------ ------ ------ ----- ------ ------ ------ ----- ------ None THERMAL MASS Vol Cond- Area Thck Heat duct- Construction Insd Mass Name (ft2) (in) Cap ivity Type Rval Location/Comments -------------- ----- ---- ---- ----------------- ---- ------------------------- None SOLAR GAIN DISTRIBUTION Fenestration Winter Summer Targetted Name Fraction Fraction Thermal Mass Comments ------------ -------- -------- ------------ -------------------------------- None HVAC DISTRIBUTION EFFICIENCY DETAILS Duct Leakage Supply Target Duct Surface ACCA Manual D (leakage cfm/ System Name Area Design % of fan cfm) Fan CFM -------------------------------------------------------------- CEC 100%R4.2 429 No n/a 1112 WATER HEATING SYSTEMS Distrib Water Water # of COMPUTER METHOD SUMMARY Volume Page 3 C -2R Project Title: COMPTON EXISTING Htrs Run: 608 18 -Mar -04 HVAC SYSTEMS Refrigerant Minimum ---- 1 ------ 0.58 Charge and Equipment Duct Location System Name System Type ------------ Airflow TXV Efficiency and R-value -------------------------- Zone = HOUSE ----------- ---------- ------------- GasFurn.78 Furnace N/A 0.78 AFUE Attic R-4.2 ACsplit10 Air cond. - central split No 10.00 SEER Attic R-4.2 HVAC DISTRIBUTION EFFICIENCY DETAILS Duct Leakage Supply Target Duct Surface ACCA Manual D (leakage cfm/ System Name Area Design % of fan cfm) Fan CFM -------------------------------------------------------------- CEC 100%R4.2 429 No n/a 1112 WATER HEATING SYSTEMS Distrib Water Water # of Energy Volume System Name Type Heater Name Heater Type Htrs Factor (gal) ------------ -------- Standard—Gas Standard ------------ StandardGas ----------------- Storage gas ---- 1 ------ 0.58 ------ 40 SPECIAL WATER HEATING SYSTEM CREDITS Solar savings Wood stove Wood stove System Name fraction boiler? boiler pump? ------------ ------------- ---------- ------------- Standard Gas -- No No SPECIAL WATER HEATER/BOILER DETAILS Rated Pilot Water Recovery Input Standby Tank Light Heater Name Efficiency AFUE (kBtuh) Loss R -value (Btuh) ---------------------- ------------------------- ------ StandardGas 78% -- 28.00 -- -- -- HYDRONIC DISTRIBUTION AND TERMINALS Pipe Pipe Insul Insul System/Name Type Number run (ft) diam (in) thck (in) R -value -------------- ------------- ------ -------- --------- --------- ------- None COMPUTER METHOD SUMMARY Page 4 C -2R Project Title: COMPTON EXISTING Run: 608 18 -Mar -04 SPECIAL FEATURES, REMARKS, AND NOTES 1. Heating duct register location: Ceiling. 2. Cooling duct register location: Ceiling. CERTIFICATE OF COMPLIANCE: Residential -------------------------------------------- Project Title: COMPTON COMPOSITE Project Address: 51-610 AVENIDA CARRANZA LA QUINTA Building Title: COMPTON COMPOSITE Document Author: DREAM ENGINEERING INC. Telephone: Page 1 CF -1R ----------------------------------- Run: 611 18 -Mar -04 `COMPTON COMPOSITE (760)242-3369 Building Permit # Plan Check / Date Compliance Method: CALRES2 1.4.02 Field Check / Date Climate Zone: 15 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- GENERAL INFORMATION Conditioned Floor Area: 1784 ft2 Conditioned? Exterior ------------------------- Average Ceiling Height: 9'0" ft -in 1784 Yes Building Type: SFD Single Family Detached Building Front Orientation: 270 deg (West) Area Fenestration Glazing Area, % of Floor Area: 10.5% Overhang Type/Orientation (ft2) Average Fenestration U-Value:0.81 SHGC Shading and Fins ----------------- Window West Average Fenestration SHGC: 0.72 ------------ 0.77 ---------- BugScrn -------•- None Number of Stories: 1 0.87 0.77 BugScrn Number of Dwelling Units: 1.00 40.2 0.60 0.65 Floor Construction Type: Slab on grade 21.6 0.87 BUILDING SHELL INSULATION BugScrn None Window South 60.0 Cavity Sheathing 0.77 BugScrn None Component Insul Insul Total Assembly Type R -value R -value ------------------------------- R -value -------- U -value -------- Location/Comments. ----------------------- Door 0 -- 3.03 0.330 Outside Wall 13 0 11.36 0.088 Outside Wall 13 0 11.36 0.088 Outside Wall 13 0 11.36 0.088 Outside Wall 13 0 11.36 0.088 , Outside Ceiling 38 0 41.67 0.024 Outside Floor 0 0 3.38 0.295 Grade Slab Perimeter 0 0 0 0.756 Outside FLOOR TYPES AND AREAS Construction Type ------------------- Area ------------ (ft2) -------------- Conditioned? Exterior ------------------------- Conditions/Descripti Slab 1784 Yes Grade FENESTRATION Area Fenestration Fenestration Exterior Overhang Type/Orientation (ft2) U -factor SHGC Shading and Fins ----------------- Window West ----- ------------ 25.0 0.87 ------------ 0.77 ---------- BugScrn -------•- None Window East 40.2 0.87 0.77 BugScrn None Window East 40.2 0.60 0.65 BugScrn None Window North 21.6 0.87 0.77 BugScrn None Window South 60.0 0.87 0.77 BugScrn None CERTIFICATE OF COMPLIANCE: Residential Page 2 CF -1R Project Title: COMPTON COMPOSITE Run: 611 18 -Mar -04 THERMAL MASS Area Thick Type Cover (ft2) (in) Location/Comments ------------------------ ----- ----- --------------------------------------- Intmassl 195.8 1.0 Interior HVAC SYSTEMS. Refrigerant Distribution System Charge and Location Type Efficiency Airflow TXV and R -value -------------------------- ---------- ----------- ------------------- Furnace 0.78 AFUE N/A Attic R-4.2 Air cond. - central split 10.00 SEER No Attic R-4.2 HVAC DISTRIBUTION EFFICIENCY DETAILS Duct Leakage Supply Target Duct Surface ACCA Manual D (leakage cfm/ System Name Area Design % of fan cfm) Fan CFM -------------------------------------------------------------- CEC-100%R4.2 482 No n/a 1249 WATER HEATING SYSTEMS Distrib Water Water # of Energy Volume System Name Type Heater Name Heater Type Htrs Factor (gal) ------------ -------- Standard—Gas Standard ------------ StandardGas ----------------- Storage gas ---- 1 ------ 0.58 ------ 40 SPECIAL WATER HEATING SYSTEM CREDITS Solar savings Wood stove Wood stove System Name fraction boiler? boiler pump? Standard Gas -- No No SPECIAL WATER HEATER/BOILER DETAILS Rated Pilot Water Recovery Input Standby Tank Light Heater Name Efficiency AFUE (kBtuh) Loss R -value (Btuh) StandardGas 78% -- 28.00 HYDRONIC DISTRIBUTION AND TERMINALS Pipe Pipe Insul Insul System/Name Type Number run (ft) diam (in) thck (in) R -value -------------- ------------- ------ -------- --------- --------- ------- None CERTIFICATE OF COMPLIANCE: Residential Page 3 CF -1R Project Title: --------------------------------------------------------------------------------- -------------------------------------------------------------------------------- COMPTON COMPOSITE Run: 611 18 -Mar -04 SPECIAL FEATURES, REMARKS, AND NOTES 1. Heating duct register location: Ceiling. 2. Cooling duct register location: Ceiling. COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with the Energy Standards in Title 24, Parts 1 and 6, of the California Code of Regulations, and the Administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features, Remarks, and Notes section. DESIGNER OR OWNER DOCUMENTATION AUTHOR DREAM ENGINEERING INC. (760)242-3369 760-564-4447 Certification #: Signed ENFORCEMENT AGENCY Name: Title: Agency: Telephone: Date // Si Signed Date (0/ Date COMPUTER METHOD SUMMARY Page 1 C -2R Project Title: COMPTON COMPOSITE Run: 611 18 -Mar -04 Project Address: 51-610 AVENIDA CARRANZA COMPTON COMPOSITE LA QUINTA Building Title: COMPTON COMPOSITE Building Permit # Document Author: DREAM ENGINEERING INC. (760)242-3369 Telephone: Plan Check / Date Compliance Method: CALRES2 1.4.02 Field Check / Date Climate Zone: 15 ENERGY USE SUMMARY (kBtu/ft2-yr) Energy Use Standard Design Space Heating 3.70 Space Cooling 41.55 Water Heating 14.03 Total Type 59.28 GENERAL INFORMATION Conditioned Floor Area: Average Ceiling Height: Building Type: Building Front Orientation: Glazing Area; % of Floor Area: Average Fenestration U -value: Average Fenestration SHGC: Number of Dwelling Units: Number of Stories: Floor Construction Type: Number of Conditioned Zones: Total Conditioned Volume: Proposed Design --------------- 3.17 63.36 12.65 -------- Complies 79.18 No 1784 ft2 9'0" ft -in SFD Single Family Detached 270 deg (West) 10.5% 0.81 0.72 1.00 1 Slab on grade 1 16054 ft3 BUILDING ZONE INFORMATION Floor Vent Zone Area Volume Thermostat Height Name (ft2) (ft3) Type Type (ft) HOUSE 1784 16054 Conditioned CEC Standard 210" OPAQUE SURFACES Surface Area U- Insl Total Tru Slr Construction Type (ft2) factor Rval Rval Azm Tlt Gns --- Type ------------ Location/Comments ------------------- ---------- Zone = HOUSE ------ ------ ---- ----- --- --- Door 20.0 0.330 0 3 270 90 Yes 30 -Wood Outside Wall 315.0 0.088 13 11 270 90 Yes W13.2x4.16 Outside Wall 536.4 0.088 13 11 0 90 Yes W13.2x4.16 Outside Wall 279.6 0.088 13 11 90 90 Yes W13.2x4.16 Outside Wall 498.0 0.088 13 11 180 90 Yes W13.2x4.16 Outside Ceiling 1783.8 0.024 38 42 -- 0 Yes R38.2x4.24 Outside Floor 1783.8 -- 0 -- -- 180 No Slabl40C Grade COMPUTER METHOD SUMMARY Page 2 C -2R Project Title: COMPTON COMPOSITE Run: 611 18 -Mar -04 PERIMETER LOSSES Insul Perimeter Length F2 Insul Depth Type (ft) Factor' R-val (in) Location/Comments ------------------- ------ ----- ------ ---------------------------------- Zone = HOUSE Exposed 204'0" 0.756 0 16 Outside FENESTRATION SURFACES Fenestration Exterior Shade Over - Fenestration Area --------------- Tru ----------------- hang Name Type (ft2) U -factor --------- SHGC ------ Azm --- Tilt ---- Type ---------- SHGC ------- /Fins ------ -------------- Zone = HOUSE ------ ----- FRONT_GLAZ Window 25.0 0.87 0.73 270 90 BugScrn 0.76 None BACK GLAZ Window 40.2 0.87 0.73 90 90 BugScrn 0.76 None BACK NEW Window 40.2 0.60 0.63 90 90 BugScrn 0.76 None LEFT_GLAZ Window 21.6 0.87 0.73 0 90 BugScrn 0.76 None RIGHT GLAZ Window 60.0 0.87 0.73 180 90 BugScrn 0.76 None OVERHANGS Fenestration -------------------------- Length Height Left Right Name Width Height 'H' 'V' Extension Extension ------------ ------ ------ ------ --------- --------- --------- None FINS Left Fin Right Fin Fenestration Dist Dist -------------------------- Fin Fin Ht from Fin Fin Ht from Name Height Width Depth Height 'V' fenes Depth Height 'V' fenes ------------ ------ ------ ------ ------ ----- ------ ------ ------ ----- ------ None THERMAL MASS Vol Cond- Area Thck Heat duct- Construction Insd Mass Name (ft2) (in) Cap ivity Type Rval Location/Comments -------------- ----- ---- ---- ----------------- ---- ------------------------- Zone = HOUSE TILE 195.8 1.0 19 0.09 Tile 0 Interior COMPUTER METHOD SUMMARY Page 3 C -2R Project Title: COMPTON COMPOSITE Run: 611 18 -Mar -04 SOLAR GAIN DISTRIBUTION Fenestration Winter Summer Targetted Name Fraction Fraction Thermal Mass Comments ------------ -------- -------- ------------ -------------------------------- None HVAC SYSTEMS Refrigerant Minimum #f of Energy Charge and Equipment Duct Location System Name System Type -------------------------- Airflow TXV ----------- Efficiency and R-value ------------ Zone = HOUSE StandardGas ---------- ------------- GasFurn.78 Furnace N/A 0.78 AFUE Attic R-4.2 ACsplit10 Air cond. - central split No 10.00 SEER Attic R-4.2 HVAC DISTRIBUTION EFFICIENCY DETAILS Duct Leakage Supply Target Duct Surface ACCA Manual D (leakage cfm/ System Name Area Design % of fan cfm) Fan CFM -------------------------------------------------------------- CEC_100%R4.2 482 No n/a 1249 WATER HEATING SYSTEMS Distrib Water Water #f of Energy Volume System Name Type Heater Name ------------ Heater Type Htrs Factor (gal) ------------ -------- Standard-Gas Standard StandardGas ----------------- Storage gas ---- 1 ------ 0.58 ------ 40 SPECIAL WATER HEATING SYSTEM CREDITS Solar savings Wood stove Wood stove System Name fraction boiler? boiler pump? ------------ ------------- ---------- ------------- Standard Gas -- No No SPECIAL WATER HEATER/BOILER DETAILS Rated Pilot Water Recovery Input Standby Tank Light Heater Name Efficiency AFUE (kBtuh) Loss R -value (Btuh) ---------------------- ------------------------- ------ StandardGas 78% -- 28.00 -- -- -- COMPUTER METHOD SUMMARY Page 4 C -2R Project Title: -------------------------------------------------------------------------------- COMPTON COMPOSITE Run: 611 18 -Mar -04 HYDRONIC DISTRIBUTION AND TERMINALS Pipe Pipe Insul Insul System/Name Type Number run (ft) diam (in) thck (in) R -value -------------- ------------- ------ -------- --------- --------- ------- None SPECIAL FEATURES, REMARKS, AND NOTES 1. Heating duct register location: Ceiling. 2. Cooling duct register location: Ceiling. -------------------------------------------------------------------------------- MANDATORY MEASURES CHECKLIST: RESIDENTIAL (Page >i of 2) MF -M Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable. DESCRIPTION DESIGNER ENFORCEMENT Building Envelope Measures: " § 150(a): Minimum R-19 ceiling insulation. x §150(b): Loose fill insulation manufacturer's labeled R -Value. § 150(c): Minimum R- 13 wall insulation in wood framed walls or equivalent U-.Pactor in metal flume walls �/ X does nota l to exterior mass walls). ' §150(d): Minimum R-13 raised floor insulation in framed floors. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no x greater than 2.0 permlinch. § 113: Insulation specified or installed meets insulation quality standards. Indicate type and form. §116-17: Fenestration Products, Exterior Doors, and Infiltration/Extiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field -fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with § 151 meets Commission quality standards. x § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control Flue damper V c. and control 2. No continuous burning gas pilot lights allowed. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. §1506): Pipe and tank insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined interval/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55° F insulated. ,X\ 6. Piping insulated between heating source and indirect hot water tank. Compliance Forms August 2001 X.5 MANDATORY MEASURES CHECKLIST: RESIDENTIAL (Page 2 of 2) MF -IR Note: Lowrise residential buildings subject to the Standards must contain these treasures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory treasures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable. DESCRIPTION J DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) * § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirement of the 1998 CMC Sections 601, 603, 604, and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or IN, 181B. If mastic or tape is used to seal openings grater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defrred or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back tubber adhesive duct tapes unless such tape is used in combination with mastic and dmwbands. 4. Exhaust ran systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shieldin • from solar radiation that can cause degradation of the material. § 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between fitter and heater for furure solar heating. b. Cover for outdoor pools or outdoor spas. �f 3. Pool system has directional inlets and a circulation pump time switch. § 115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) §118(f): Cool Roof material meet specified criteria Lighting Measures: §150(k)l.: Luminaires for general lighting in kitchens shall have lamps with an efficacy of 40 lumerns/watt ort reater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily �[ accessible lightin • control panel at an entrance to the kitchen. / \ § I50(k)2.: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternatives to this requirement allowed in § 150(k)2.; and incandescent recessed ceiling fixtures are IC (insulation cover) approved. Compliance Forms August 2001 A-6 INSTALLATION CERTIFICATE (Page 1 of 13) CF -CR Site Address Permit Number An installation certificate is required to be posted at the building site or made available for all appropriate inspections. (The information provided on this form is required; however, use of this form to provide the information is optional.) After completion of final inspection, a copy must be provided to the building department (upon request) and the building owner at occupancy, per Section 10-103(b). HVAC SYSTEMS: Heating Equipment Equip. # of Efficiency Duct Duct or Heating Heating Type (pkg. CEC Certified Mfr Natne Identical (AFUE, etc.) Location Piping Load Capacity heat oumn) and Model Number Systems 2CF-1R valuel (attic. etc.) R -value (Btu/hr) (Btu/hr) Cooling Equipment Equip. CEC Certified Compressor # of Efficiency Duct Cooling Cooling Type (pkg. Unit Mfr Name and Identical (SEER, ctc.)' Location Duct Load Capacity heat pump) Model Number Systems (>_CF -1R valuel (attic, etc.) R -value (Btu/hr) (Btu/h[) 1. > reads greater than or equal to. I, the undersigned, verify that equipment listed above is: 1) is the actual equipment installed, 2) equivalent to or more efficient than that specified in the.certificate of compliance (Form CF -1R) submitted for compliance with the Energy Efficiency Standards for residential buildings, and 3) equipment that meets or exceeds the appropriate requirements for manufactured devices (from the Appliance Efficiency Regulations or Part 6), where applicable. Signature, Date Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner WATER HEATING SYSTEMS: Distribution If Recir- # of Rated' Tank Effi- External Heater CL•C CertifiedMtr Type (Std, culation, Identical Input (kW Volume ciency'- Standby' Insulation Type Name & Model Number Point -of -Use) Control Type Systems or Bm/hr) (gallons) (EF, RE) Loss (%) R -valet 2 For small gas storage (rated input of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list Energy Factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Recovery Efficiency, Standby Loss and Rated Input. For instantaneous gas water heaters, list Recovery Efficiency and Rated Input. 3. R-12 external insulation is mandatory for storage water heaters with an energy factor of less than 0.58. Faucets & Shower Heads: All faucets and showerheads installed are certified to the Commission, pursuant to Title 24, Part 6, Section 111. I, the undersigned, verify that equipment listed above my signature is: 1) the actual equipment installed; 2) equivalent to or more efficient than that specified in the certificate of compliance (Form CF -IR) submitted for compliance with the Enera Efficiency Standards for residential buildings; and 3) equipment that meets or exceeds the appropriate requirements for manufactured devices (from the Appliance Effrciencv Regulations or Part 6), where applicable. Signature, Date COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner Compliance Forms August 2001 A-23 NSTALLATION CERTIFICATE (Page 2 of 13) CF -6R Site Address Permit Number FEN ESTRATION/GLAZING: Total Quantity Product Product of Like Exterior Shading U -Factor (5 SHGC' (< # of Product Square Device or Comments/Location/ Manufacturer/ElrandName CF-1Rvalue)2 CF-1Rvalue)' Panes (Optional) Feet Overhang Special Features (GROUP LIKE PRODUCTS) 1. 2. 3. ---- --- — . 4 --- -- - — -- ----- --- -- 4. -- — — -- 6. --- — -- — — ---- --- — 7. 8.- — — 9. - -- --- ---- ---- -- 10. 11. - -- -- - 12. 1.3. — --- -- — 14. 15. Manufactured fenestration products use the values from the product label. Field fabricated fenestration products use the default values from Section 116 of the Energy Efficiency Standards. ' Installed U -Factor must be less than or equal to values from CF -1 R. Installed SHGC must be less than or equal to values from CF -1R, or a shading device (exterior or overhang) is installed as specified on the CF -1R. Alternatively, installed weighted average U -Factors for the total fenestration area are less than or equal to values from CF -IR. I, the undersigned, verify that the fenestration/glazing listed above my signature: 1) is the actual fenestration product installed; 2) is equivalent to or has a lower U -Factor and lower SHGC than that specified in the certificate of compliance (Form CF -1R) submitted for compliance with the Energv Efciencv Standards for residential buildings; and 3) the product meets or exceeds the appropriate requirements for manufactured devices (from Part 6), where applicable. Item #s Signature, Date (if applicable) Item #s Signature, Date (if applicable) Item #s Signature, Date (if applicable) COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner OR Window Distributor Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner OR Window Distributor Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner OR Window Distributor Compliance Forms August 2001 A-24 INSTALLATION CERTIFICATE (Page 3 of 13) CF -6R Site Address Permit Number DUCT LEAKAGE AND DESIGN DIAGNOSTICS _ ❑ DUCT LEAKAGE REDUCTION Pressurization Test Results (CFM @ 25 PA) Test Leakage (CFM) Fan Flow If Fan Flow is Calculated as 400 cfin/ton x number of tons, or as 21.7 x .Heating Capacity in Thousands of Btu/hr, enter calculated value here If fan flow is measured, enter measured value here Leakage Fraction = Test Leakage/(Measured or Calculated Fan Flow) = Pass if leakage fraction 5 0.06 ❑ [] Pass Fail ❑ For AEROSOL TYPE SEALANTS ONLY - The following diagnostic testing was completed: Duct Fan Pressurization at rough -in measured leakage (CFM) CHECK AFTER FINISHING WALL: ❑ Yes ❑ No ❑ Pressure pan test or House pressurization test ❑ Yes ❑ No ❑ Visual Inspection of Duct Connections ❑ ❑ Pass Fail ❑ THERMOSTATIC EXPANSION VALVE (TXV) ❑ Yes ❑ No Thermostatic Expansion Valve is installed and Access is provided for inspection ❑ ❑ Yes is a pass Pass Fail ❑ DUCT DESIGN 1 ❑ Yes ❑ No ACCA Manual D Design calculations have been completed, Duct Design is on the plans and duct installation matches plans. 2. ❑ Yes ❑ No TXV is installed or Fan flow has been verified. If no TXV, verified fan flow matches design from CF -1R. Measured Fan Flow = ❑ ❑ Yes for both 1 and 2 is a Pass Pass Fail ❑ I, the undersigned, verify that the above diagnostic test results and the work I performed associated with the test(s) is in conformance with the requirements for compliance credit. [The builder shall provide the HERS provider a copy of the CF -6R signed by the builder employees or sub -contractors certifying that diagnostic testing and installation meet the requirements for compliance credit.] Tests Signature, Date Performed COPY TO: Building Department. HERS Provider (if applicable) Building Owner at Occupancy Installing Subcontractor (Co. Naive) OR General Contractor (Co. Name) Compliance Forms August 2001 A-25 INSTALLATION CERTIFICATE (Page 4 of 13) CF -6R Site Address Permit Number REFRIGERANT CHARGE AND AIRFLOW MEASUREMENT Verification for Required Refrigerant Charge and Adequate Airflow for Split System Space Cooling Systems without Thermostatic Expansion Valves Outdoor Unit Serial # Outdoor Unit Make Outdoor Unit Model Cooling Capacity Date of Verification Date of Refrigerant Gauge Calibration Date of Thermocouple Calibration Btu/hr (must be checked monthly) (must be checked monthly) Standard Charge and Airflow Measurement (outdoor air dry-bulb 55 T and above): Note: The system should be installed and charged in accordance with the manufacturer's specifications before starting this procedure. Measured Temperatures Supply (evaporator leaving) air dry-bulb temperature (Tsupply, db) OF Return (evaporator entering) air dry-bulb temperature (Tretorn, db) OF Return (evaporator entering) air wet -bulb temperature (Treturn, wb) OF Evaporator saturation temperature (Tevaporator, sat) OF Suction Line temperature (Tsuction, db) OF Condenser (entering) air dry-bulb temperature (Tcondenser, db) OF Superheat Charge Method Calculations for Refrigerant Charge Actual Superheat = Tsuction, db — Tevaporator, sat. °F Target Superheat (from Table 1) OF Actual Superheat— Target Superheat OF (System passes if between -5 and +5'F) Temperature Split Method Calculations for Adequate Airflow Actual Temperature Split = T return, db - Tsupply, db OF Target Temperature Split (from Table 2) OF Actual Temperature Split - Target Temperature Split °F (System passes if between -3°F and +3°F or, upon remeasurement, if between +3°F and -25'F) Standard Charge and Airflow Measurement Summary: System shall pass both refrigerant charge and adequate airflow calculation criteria from the same measurements. If corrective actions were taken, both criteria must be remeasured and recalculated System Passes yes or no Compliance Forms August 2001 A-26 INSTALLATION CERTIFICATE (Page 5 of 13) CF -6R Site Address Permit Number Alternate Charge and Airflow Measurement (outdoor air dry-bulb below 55 °F): Weigh -In Charging Method for Refrigerant Charge Actual liquid line length: $, Manufacturers Standard liquid line length: ft. Difference (Actual — Standard): $. Manufacturers correction (ounces per foot) _ x difference in length = ounces (+ = add) (- = remove) Measured Airflow Method for Adequate Airflow Airflow criterion: Cooling Capacity X 0.032 = __ CFM Measured Airflow is _CFM and passes since it is greater than the criterion. Alternate Charge and Airflow Measurement Summary: System charge shall be corrected and it shall also pass measured adequate airflow criterion. System Passes yes or no Compliance Forms August 2001 A-27 INSTALLATION CERTIFICATE (Page 6 of 13) CF -6R Site Address Permit Number Table K-1: Target Superheat (Suction Line Temperature - Evaporator Saturation Temperature) Compliance Forms August 2001 A-28 Return Air Wet -Bulb Temperature (°F) 50 51 52 53 54 1 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 55 8.8 10.1 11.5 12.8 14.2 1 15.6 17.1 18.5 20.0 21.5 23.1 24.6 26.2 1 27.8 29.4 31.0 32.4 1 33.8 35.1 36.4 37.7 39.0 40.2 41.5 42.7 43.9 45.0 56 8.6 8.3 7.9 7.5 7.0 9.9 9.6 9.3 8.9 1 8.4 11.2 11.0 10.6 10.2 9.8 12.6 12.3 12.0 11.6 1 11.2 14.0 13.7 13.4 13.0 1 12.6 15.4 15.1 14.8 14.4 14.0 16.8 16.5 16.2 15.8 15.4 18.2 17.9 17.6 17.2 16.8 19.7 19.4 19.0 18.6 18.2 21.2 20.8 20.4 20.0 19.6 22.7 22.3 21.9 21.4 21.0 24.2 23.8 23.3 22.9 22.4 25.7 25.3 24.8 24.3 23.8 27.3 26.8 26.3 25.7 25.2 28.9 28.3 27.8 27.2 26.6 30.5 29.9 29.3 28.7 28.1 31.8 31.3 30.7 30.1 29.6 33.2 32.6 32.1 31.5 31.0 34.6 34.0 33.5 32.9 32.4 35.9 35.3 34.8 34.3 33.7 37.2 36.7 36.1 35.6 j 35.1 38.5 38.0 37.5 36.9 36.4 39.7 39.2 38.7 38.3 37.8 41.0 40.5 40.0 39.5 39.1 42.2 41.7 41.3 40.8 40.4 43.4 43.0 42.5 42.1 1 41.6 44.6 44.2 43.7 43.3 42.9 57 58 59 60 61 6.5 6.0 5.3 - 7.9 7.4 6.8 6.1 5.4 9.3 8.8 8.3 7.6 7.0 10.7 10.2 9.7 9.1 8.5 12.113.5 11.7 11.1 10.6 10.0 13.1 12.6 1 12.0 i 11.5 14.9 14.5 14.0 13.5 12.9 16.3 15.9 15.4 14.9 14.3 17.7 17.3 16.8 16.3 1 15.8 19.1 18.7 18.2 17.7 17.1 20.5 20.1 19.6 19.0 1 18.5 21.9 21.4 20.9 20.4 1 19.9 23.3 22.8 22.3 21.7 21.2 24.7 24.2 23.6 23.1 1 22.5 26.1 25.5 25.0 24.4 23.8 27.5 27.0 26.4 25.8 25.2 29.0 28.4 27.8 27.3 1 26.7 30.4 29.9 29.3 28.7 1 28.2 31.8 31.3 30.7 30.2 29.7 33.2 32.7 32.2 31.6 31.1 34.6 34.1 33.6 33.0 32.5 35.9 35.4 34.9 34.4 33.9 37.3 36.8 36.3 35.8 35.3 38.6 38.1 37.7 37.2 36.7 39.9 39.4 39.0 38.5 38.1 41.2 40.7 40.3 39.9 39.4 42.4 42.0 41.6 41.2 40.8 62 63 64 65 °. E .. 66 - 6.3 5.5 7.8 7.1 6.3 5.5 - 9.3 8.7 8.0 7.2 6.4 10.8 10.2 19.5 18.8 18.1 1 12.3 11.7 11.1 10.4 9.7 13.8 13.2 12.6 11.9 11.2 15.2 14.6 14.0 13.4 12.7 16.6 16.0 15.5 14.8 14.2 18.0 17.4 16.8 16.3 15.7 19.3 18.8 18.2 17.6 17.0 20.7 20.1 19.5 19.0 18.4 22.0 21.4 20.8 203 19.7 23.2 22.7 22.1 21.5 1 20.9 24.6 24.1 23.5 22.9 22.3 26.1 25.6 25.0 24.4 23.9 27.6 27.1 26.5 26.0 25.4 29.1 28.6 28.0 27.5 27.0 30.6 30.1 29.5 29.0 1 28.5 32.0 31.5 31.0 30.5 1 30.0 33.4 33.0 32.5 32.0 31.5 34.9 34.4 33.9 33.4 1 33.0 36.3 35.8 35.3 34.9 1 34.4 37.6 37.2 36.8 36.3 35.9 39.0 38.6 38.1 37.7 1 37.3 40.4 39.9 39.5 39.1 1 38.7 67 68 69 70 F" 4. F? a 71 5.6 i 7.3 16.4 5.6 - - 8.9 8.1 7.3 6.5 5.6 1 10.5 9.8 9.0 8.2 7.4 1 12.1 11.4 10.7 9.9 92 13.6 12.9 12.2 11.5 10.8 1 15.0 14.4 13.7 13.1 12.4 1 16.4 15.8 15.2 14.5 13.9 17.8 17.2 16.6 15.9 15.3 1 19.1 18.5 17.9 17.3 16.7 20.3 19.7 19.2 18.6 18.0 21.7 21.2 20.6 20.0 19.4 1 23.3 22.8 22.2 21.6 21.1 1 24.9 24.3 23.8 23.2 22.7 26.4 25.9 25.4 24.8 24.3 28.0 27.4 26.9 26.4 25.9 29.5 29.0 28.5 28.0 27.5 31.0 30.5 30.0 29.5 29.1 32.5 32.0 31.5 31.1 30.6 34.0 33.5 33.1 32.6 32.2 35.4 35.0 34.6 34.1 33.7 36.9 36.5 36.0 35.6 35.2 38.3 37.9 37.5 37.1 36.7 72 73 74 75 4 h ,D c 76 - 6.6 5.7 8.4 7.5 6.7 5.9 10.1 9.3 8.5 7.7 6.9 11.7 11.0 10.2 9.5 8.7 13.2 12.5 11.8 11.1 10.4 14.7 14.0 13.4 12.7 12.0 16.1 15.4 14.8 14.2 13.5 17.4 16.8 16.2 15.6 15.0 18.9 18.3 17.7 17.1 16.6 20.5 20.0 19.4 18.8 183 22.1 21.6 21.1 20.5 20.0 23.8 23.2 22.7 22.2 21.7 25.4 24.9 24.4 23.8 23.3 27.0 26.5 26.0 25.5 25.0 28.6 28.1 27.6 27.1 26.7 30.1 29.7 29.2 28.8 28.3 31.7 31.3 30.8 30.4 29.9 33.3 32.8 32.4 32.0 31.6 34.8 34.4 34.0 33.6 33.2 36.3 36.0 35.6 35.2 34.8 77 78 79 80 81 6.0 52 - 7.9 7.1 6.3 5.5 9.7 8.9 8.2 7.4 6.6 11.3 10.6 9.9 9.2 8.5 12.9 122 11.6 10.9 10.3 14.3 13.7 13.1 12.5 11.9 16.0 15.4 14.9 14.3 13.7 17.7 17.2 16.6 16.1 15.5 19.4 18.9 18.4 17.8 17.3 21.1 20.6 20.1 19.6 19.0 22.8 22.3 21.8 21.3 20.8 24.5 24.0 23.5 23.0 22.6 26.2 25.7 25.2 24.8 24.3 27.9 27.4 26.9 26.5 26.0 29.5 29.1 28.6 28.2 27.8 31.2 30.7 30.3 29.9 29.5 32.8 32.4 32.0 31.6 31.2 34.4 34.0 33.7 33.3 32.9 82 83 84 85 86 5.8 5.0 - 7.8 7.0 6.3 5.5 9.6 8.9 32 7.5 6.8 11.3 10.6 10.0 9.4 8.8 1 13.2 12.6 12.0 11.5 10.9 1 15.0 14.4 13.9 13.3 12.8 16.7 16.2 15.7 15.1 14.6 18.5 18.0 17.5 17.0 16.5 20.3 t9.8 19.3 18.8 18.3 22.1 21.6 21.1 20.6 20.1 23.8 23.4 22.9 22.4 22.0 25.6 25.1 24.7 24.3 23.8 1 27.3 26.9 26.5 26.1 25.6 29.1 28.7 28.3 27.9 27.5 30.8 30.4 30.1 29.7 29.3 32.6 32.2 31.8 31.5 31.1 87 88 89 90 Compliance Forms August 2001 A-28 INSTALLATION CERTIFICATE (Page 7 of 13) CF -6R Site Address Permit Number Table K -l: Target Superheat (Suction Line Temperature - Evaporator Saturation Temperature) (continued) Compliance Forms August 2001 A-29 Return Air Wet -Bulb Temperature ff) c63 50 1 51 52 53 1 54 55 56 57 58 59 1 60 61 62 1 1 64 65 66 1 67 68 69 70 71 1 72 73 74 75 76 91 - - - - - - - - - - - - - 6.1 5.4 - 8.1 7.5 6.8 6.2 5.6 10.3 9.8 9.2 8.7 8.1 12.2 11.7 11.1 10.6 10.0 14.1 13.5 13.0 12.5 12.0 15.9 15.4 14.9 14.4 13.9 17.8 17.3 16.8 16.3 15.8 19.7 19.2 18.7 18.2 17.8 21.5 21.1 20.6 20.2 19.7 23.4 22.9 22.5 22.1 21.6 25.2 24.8 24.4 24.0 23.6 27.1 26.7 26.3 25.9 25.5 28.9 28.5 28.2 27.8 27.4 30.8 30.4 30.1 29.7 29.4 92 93 94 95 fs F ° 2 96 I ( - - 7.5 7.0 6.4 5.8 5.3 9.5 8.9 8.4 7.9 7.3 11.4 10.9 10.4 9.9 9.3 13.4 12.9 12.4 11.9 11.4 15.3 14.9 14.4 13.9 13.4 17.3 16.8 16.4 15.9 15.4 19.2 18.8 18.3 17.9 17.5 21.2 20.8 20.3 19.9 19.5 23.2 22.7 22.3 21.9 21.5 25.1 24.7 24.3 24.0 23.6 27.1 26.7 26.3 26.0 25.6 29.0 28.7 28.3 28.0 27.7 97 98 99 100 � a r £ A 101 102 103 104 - 6.8 6.2 5.7 5.2 8.8 8.3 7.8 7.2 6.7 10.9 10.4 9.9 9.3 8.8 12.9 12.4 11.9 11.5 11.0 1 15.0 14.5 14.0 13.6 13.1 17.0 16.6 16.1 15.7 15.2 1 19.1 18.6 18.2 17.8 17.4 1 21.1 20.7 20.3 19.9 19.5 23.2 22.8 22.4 22.1 21.7 1 25.3 24.9 24.5 24.2 23.8 27.3 27.0 26.7 26.3 26.0 105 Q v j 106 - I - 6.2 5.7 5.2 - 8.3 7.9 7.4 6.9 6.4 -10.5 10.0 9.5 9.1 8.6 12.6 12.2 11.7 11.3 10.8 1 14.8 14.4 13.9 13.5 13.1 17.0 16.6 16.1 15.7 15.3 19.1 18.7 18.4 18.0 17.6 21.3 21.0 20.6 20.2 19.9 23.5 23.2 22.8 22.5 22.1 1 25.7 25.4 25.1 24.7 24.4 107 108 109 110 111 I - 5.9 5.4 - 8.1 7.6 7.2 6.7 6.2 10.4 9.9 9.5 9.0 8.6 12.6 12.2 11.8 11.4 10.9 i 14.9 14.5 14.1 13.7 13.3 1 17.2 16.8 16.4 16.1 15.7 19.5 19.1 18.8 18.4 18.1 21.8 21.5 21.1 20.8 20.5 24.1 23.8 23.5 23.2 22.9 112 113 114 I l5 Compliance Forms August 2001 A-29 INSTALLATION CERTIFICATE (Page 8 of 13) CF -6R Site Address Permit Number Table K-2: Target Temperature Split (Return Dry -Bulb - Supply Dry -Bulb) Return Air Wet -Bulb (T) (Tmur.,, b) 50 51 52 53 54 55 56 57 1 58 59 60 61 62 1 63 1 64 65 66 1 67 68 1 69 1 70 71 72 73 74 75 76 70 20.9 20.7 20.6 20.4 20.1 19.9 19.5 19.1 18.7 18.2 17.7 17.2 16.5 15.91 15.2 14.4 13.7 12.8 11.91 11.01 10.0 9.0 7.9 6.8 5.7 4.5 3.2 71 21.4 21.3 21.1 20.9 20.7 20.4 20.1 19.7 19.3 18.8 18.3 17.7 17.1 16.4 15.7 15.0 14.2 13.4 12.5 11.5 10.6 9.5 8.5 7.4 6.2 5.0 3.8 _ 72 21.9 21.8 21,7 21.5 21.2 20.9 20.6 20.2 19.8 19.3 18.8 18.2117.6 17.0 16.3 15.5 14.7 13.9 13.0 12.1 11.1 10.1 9.0 7.9 6.8 5.6 4.3 22.5 22.4 22.2 22.0 21.8 21.5 21.2 20.8 20.3 19.9 19.4 18.8118.2 17.5 16.8 16.1 15.3 14.4 13.6 12.6 11.7 10.6 9.6 8.5 7.3 6.1 4.8 73 F 23.0 22.9 22.8 22.6 22.3 22.0 21.7 21.3 20.9 20.4 19.9 19.31 18.7 18.1 17.4 16.6 15.815.0 14.1 13.2 12.2 11.2 10.1 9.0 7.8 6.6 5.4 74 23.6 23.5 23.3 23.1 22.9 22.6 22.2 21.9 21.4 21.0 20.4 19.9 19.3 18.6 17.9 17.2 16.4 15.5 14.7 13.7 12.7 11.7 10.7 9.S 8.4 7.2 5.9 75 76 24.1 24.0 23.9 23.7 23.4 23.1 22.8 22.4 22.0 21.5 21.0 20.4 19.8 19.2 18.5 17.7 16.9 16.1 15.2 14.3 13.3 12.3 11.2 10.1 8.9 7.7 6.5 77 Ca - 24.6 24.4 24.2 24.0 23.7 23.3 22.9 22.5 22.0 21.5 21.0 20.4 19.7 19.0 18.3 17.5 16.6 15.7 14.8 13.8 12.8 ( 11.7 10.6 9.5 8.3 7.0 24.7 24.5 24.2 23.9 23.5 23.1 22.6 22.1 21.5 20.9 20.2 19.5 18.8 18.0 17.2 16.3 15.4 14.4 13.4 12.3 11.2 10.0 8.8 7.6 78 79 A - - 24.8 24.4 24.0 23.6 23.1 22.6 22.1 21.4 20.8 20.1 19.3 18.5 17.7 16.8 15.9 14.9 3.9 12.8 11.7 10.6 9.4 8.1 Q 25.0 24.6 24.2 23.7 23.2 22.6 22.0 21.3 20.6 19.9 19.1 18.3 17.4 16.4 15.5 14.4 13.4 12.3 11.1 9.9 8.7 80 81 25.1 24.7 24.2 23.7 23.1 22.5 21.9 21.2 20.4 19.6 18.8 17.9 17.0 16.0 15.0 13.9 12.8 11.7 10.4 9.2 o y - - 25.2 24.8 24.2 23.7 23.1 22.4 21.7 21.0 20.2 19.3 18.5 17.5 16.6 15.5 14.5 13.4 12.2 11.0 9.7 82 I 25.3 24.8 24.2 23.6 23.0 22.3 21.5 20.7 19.9 19.0 18.1 17.1 16.1 15.0 13.9 12.7 11.5 10.3 83 - 25.9 25.3 24.8 24.2 23.5 22.8 22.1 21.3 20.4 19.5 18.6 17.6 16.6 15.6 14.4 13.3 12.1 10.8 84 Compliance Forms August 2001 A-30 .INSTALLATION CERTIFICATE (Page 9 of 13) CF -6R Site Address Permit Number DUCT LOBATION AND AREA REDUCTION DIAGNOSTICS ❑ DUCT IN CONDITIONED SPACE ❑ Yes ❑ No Duct in conditioned space criteria matches CF -1 R ❑ ❑ Yes is a Pass Pass Fail ❑ REDUCED DUCT SURFACE AREA Measured duct exterior surface area in the following unconditioned duct locations (square feet): Attics Crawlspaces Basements Other (e.g., garages, etc.) ❑ Yes I❑ No Duct surface area matches CF -1 R? ❑ ❑ Yes is a Pass Pass Fail ❑ I, the undersittmed, verify that the duct surface area and duct locations claimed for duct surface area reductions and duct location improvements beyond those covered by default assumptions match those on the plans. (The builder shall provide the HERS provider a copy of the CF -6R signed by the builder employees or sub -contractors certifying that diagnostic testing and installation meet the requirements for compliance credit.] Tests Signature, Date installing Subcontractor (Co. Natne) OR Performed General Contractor (Co. Name) COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy Compliance Forms August 2001 A-31 •INSTALLATION CERTIFICATE (Page 10 of 13) CF -16R Site Address Permit Number BUILDING ENVELOPE LEAKAGE DIAGNOSTICS ❑ ENVELOPE SEALING INFILTRATION REDUCTION Diagnostic Testing Results Building Envelope Leakage (CFM @ 50 Pa) as measured by Rater 1. ❑ Is measured envelope leakage less than or equal to the required level from Yes No CF -1R? 2. ❑ Is Mechanical Ventilation shown as required on the CF -1R? Yes No 2a. ❑ If Mechanical Ventilation is required on the CF- IR (Yes in line 2), has it Yes No been installed? 2b. ❑ ❑ Check this box yes if mechanical ventilation is required (Yes in line 2) Yes No and ventilation fan watts are no greater than shown on CF -IR. Measured Watts = 3. ❑ ❑ Check this box yes if measured building infiltration (CFM @ 50 Pa) is Yes No greater than the CFM @ 50 values shown for an SLA of 1.5 on CF -1R (If this box is checked no, mechanical ventilation is required.) 4. ❑ Check this box yes if measured building infiltration (CFM @ 50 Pa) is less Yes No than the CFM @ 50 values shown for an SLA of 1.5 on CF -1R, mechanical ventilation is installed and house pressure is greater than minus 5 Pascal with all exhaust fans operating. ❑ ❑ Pass if: Pass Fail d. Yes in Line I and line 3, or e. Yes in line 1 and line2, 2a, and 2b, or f. Yes in line 1 and Yes in line 4. Otherwise fail. ❑ 1, the undersigned, verify that the building envelope leakage meets the requirements claimed for building leakage reduction below default assumptions as used for compliance on the CF -IR. This is to certify that the above diagnostic test results and the work I performed associated with the test(s) is in conformance with the requirements for compliance credit. [The builder shall provide the HERS provider a copy of the CF -6R signed by the builder employees or sub -contractors certifying that diagnostic testing and installation meet the requirements for compliance credit.] Test Performed Signature Date COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy Testing Subcontractor (Co. Name) OR General Contractor (Co. Name) Compliance Forms August 2001 A-32 INSTALLATION CERTIFICATE (Page 11 of 13) CF -6R Site Address Permit Number The following is an explanation of many of the input values required on this form: HVAC SYSTEMS Heating Equipment Type must be one of the following: Furnace: Gas (including Liquefied Petroleum Gases) or oil -fired central furnace & space heater Boiler: Gas or oil -fired boiler PckgHeatPump: Packaged central heat pump SplitHeatPump: Split central heat pump RoomHeatPump: Room heat pump I.,gPkgHeatPump: Large packaged heat pump (>_ 65,000 Btu/hr output) Electric: Electric resistance heating (fixed HSPF = 3.413); .radiant electric resistance (fixed HSPF = 3.55) Coimbinedflydro: Reference water heater under water heating systems below CEC Certified Manufacturer Name & Model Number from applicable Commission approved appliance directory. # of Identical Systems is for those systems with the same efficiency, duct. location, duct R -value and capacity. Efficiency from applicable Commission certified appliance directory. Duct (or Piping) Location is attic, crawl space, CVC crawl space, conditioned space, unconditioned space or none. Duct (or Piping) R -Value from Directory of Certified Insulation Materials and/or manufacturer's data. Heating/Cooling Load refer to Commission approved load calculation procedure. Heating/Cooling Capacity from the applicable Commission certified appliance directory. Note: location elevations over 2,000 fl above sea level require a derating of output capacity (refer to manufacturer's literature). looting Equipment T e must be one of the following: SplitAirCond: Split system air conditioner PckgAirCond: Packaged air conditioner Split Heat Pump: Split system heat pump PckgHeatPump: Packaged heat pump RoomHeatPump: Room heat pump L gPkgHeatPump: Large packaged heat pump (>_ 65,000 Btu/hr output). Substitute EER for SEER when SEER is not available RooinAirCond: Room air conditioner. Minimum SEER varies* LgPkgAirCond: Large packaged air conditioner (>_ 65,000 Btu/hr output). Substitute EER for SEER when SEER is not available EvapDirect: Direct evaporative cooling system. For compliance calculation purposes, fixed values: SEER = l 1.0; duct location = attic; duct insulation R -value = 4.2 Evapindirect: Indirect evaporative cooling system. For compliance calculation purposes, fixed values: SEER = 13.0; duct location = attic; duct insulation R -value = 4.2 `Refer to Energy Commission publication Appliance Efficiency Regulations, P400-92-029 Compliance Forms August 2001 A-33 r E`4STALLATION CERTIFICATE (Page 12 of 13) CF -6R Site Address Permit Number The following is an explanation of many of the input values required on this form: WA'rER HEATING SYSTEMS Distribution Systems Refer to Residential Manual for more details: Standard: Standard — Supply pressure based system, no pumps Pipe Insulation: Pipe Insulation on all 3/4 -inch pipes POU/HWR: Point of Use/Hot Water Recovery System Recirc/NoControl: Recirculation loop with no controls Recirc/Timer: Recirculation loop with a timer Recirc/Temp: Recirculation loop with temperature control Recirc/Time+Temp: Recirculation loop with a timer and temperature control Recirc/Demand: Recirculation loop with demand control Water Heater Tyne Windows, sliding glass doors, French doors, skylights, garden windows, and Information Needed any door with more than one square foot of glass Operator Type: Energy Factor Recovery Efficiency Standby Loss Rated Input Storage Gas, Oil or Electric Yes No No No Heat Pump Yes No No No Instantaneous Gas No Yes No No Instantaneous Electric Yes No No No Large Storage Gas No Yes Yes Yes Indirect Gas (Boiler) No Yes (AFUE) No Yes FENESTRATION/GLAZING Fenestration: Windows, sliding glass doors, French doors, skylights, garden windows, and any door with more than one square foot of glass Operator Type: Slider, hinged, fixed U -Factor: Installed U -Factor must be less than or equal to value from CF -1R OR Installed weighted average U -Factor for the total fenestration area is less than orequal to value from CF -1R SHGC: Installed SHGC must be less than or equal to value from CF -1R OR Installed weighted SHGC for the total fenestration area is less than or equal to value from CF -1R OR An interior shading device, overhang, or exterior shading device is installed consistent with the CF -IR Shading Device: Include when the building complied using an exterior shading device: woven sunscreen, louvered sunscreen, low sun angle sunscreen, roll -down awning, roll -down blinds or slats (do not list bug screen), or an overhang (include depth in feet Compliance Forms August 2001 A-34 INSTALLATION CERTIFICATE (Page 13 of 13) CF -6R Site Address Permit Number The following is an explanation of many of the input values required on the Diagnostic portion of this form (page 3 oI.6): TYPE OF CREDIT Refer to Residential Manual Chapters 4 and 5 for more details: Reduced Duet Surface Area: Calculated as the outside area of the duct. Areas must be measured and verified by a HERS rater. Improved Duct Location: Supply duct located in other than attic, as verified by location of registers (does not require HERS rater verification). Catastrophic Leakage: Pressure pan test readings must be less than 1.5 Pascal at a house pressure of 25 Pascal. TXV: Access cover requited to facilitate verification. Infiltration Reduction: Infiltration is measured without mechanical ventilation operating. Mechanical ventilation is required for very tight house construction when credits for infiltration reduction using diagnostic testing are being used for achieving compliance. These very tight houses are defined as those with SLA of less than I.S. The compliance documentation (CF -1R) will contain the measured CFM target value from a blower door test at 50 Pascal pressure difference that represents this SLA of 1.5. Mechanical ventilation is also required if the builder chooses to design the building to use mechanical ventilation and claims a credit for infiltration below an SLA of 3.0. The compliance documentation (CF -1R) will contain the measured CFM target value that represents this 3.0 SLA. If the builder claims credit in a design for infiltration reduction that is at an SLA of 3.0 or higher, and the actual measured SLA is 1.5 or greater, then mechanical ventilation is not required. If the SLA in this case were below 1.5, then mitigation (such as mechanical ventilation) would be required. Compliance Forms August 2001 A-35 perimeter 204.0 Slab 1,588.0 Area 1,588.0 lazin 167.0 average ceiling height 9.0 Calculation Work Sheet Existing Engineering Incorporated 1981 20th Anniversary 2001 Consulting Electrical Engineers 19W1 Highw"+' IV S. 200 72330'(:aT'� I.m1c. Appk VNk y. CA 92307 Pulm D. -It G 91]60 rnm.•: (760) 2,0 Ph- (760)7 3-"78 Yqa: (760)242-IW2 Va.: (760)213-1093 dn+ny:�'�dmMrsN dnvmJuc�rtuuL�vm FRONT HEIGHT GLAZING W H AREA 5.0 5.0 25.0 u so 0.87 0.70 CODE DREAM 25.0 1 0.87 0.70 LEFT HEIGHT 9.0 WALL AREA FRONT 40.0 360.0 LEFT 62.0 558.0 BACK 40.0 360.0 RIGHT 62.0 558.0 0.70 1.836.0 LEFT CODE GLAZING H AREA CODE W H AREA u sc GBLK 2.0 2.8 5.6 0.87 0.70 TOTAL 4.0 4.0 16.0 0.87 0.70 6.0 6.7 40,2 0.87 0.70 61.8 1 0.87 1 0.70 SKYLIGHTS CODE I W H AREA u sc NONE 0.87 0.70 7.0 5.0 35.0 0.87 TOTAL BACK GLAZING CODE W H AREA u. sc 6.0 6.7 40.2 0.87 0.70 40.2 0.87 1 0.70 DOORS CODE W H AREA front 3.0 6,7 20.1 FOTAL 1 20.1 RIGHT GLAZING W H AREA u so CODE 5.0 5.0 25.0 0.87 0.70 7.0 5.0 35.0 0.87 0.70 1 60.0 i 0.87 1 0.80 I (i Calculation Work Sheet perimeter 204.0 Slab 1,783.8 Area 1,783.8 glazing 187.0 average ceiling height 9.0 Composite Engineering Incorporated 1981 20th Anniversary 2001 Consulting Electrical Engineers 1903110amey 16 Sic 2W 723306Lm,m",r Applin V.0 y, rA 929117 Pdm D� rs 92260 rb-: (7W) 242-3369 Pb- (703) 773-4478 F-: (760) 242-1092 F- (760)242 -IM Jrt�ja�n\�n,r.nct d.uul Iryq.,La FRONT HEIGHT GLAZING W H AREA 5.0 5.0 25.0 u 1.28 sC 0.99 40.0 DREAM 25.0 1,28 1 0.99 LEFT HEIGHT 9.0 WALL AREA FRONT 40.0 360.0 LEFT 62.0 558.0 BACK 40.0 360.0 RIGHT 62.0 558.0 1,836.0 LEFT CODE W H GLAZING W H AREA 2.0 2.8 5.6 4.0 4.0 16.0 u 0.87 0.87 SC 0.70 0.70 GBLK 21.6 0.87 0.70 SKYLIGHTS CODE W H I AREA u so NONE 80.4 0.74 10.68 1.281 0.99 TOTAL BACK GLAZING W H AREA 6.0 6.7 40.2 6.0 6.7 40.2 u 0.87 0.60 SC 0.70 0.65 NEW 80.4 0.74 10.68 1.281 DOORS W H AREA Existing 3.0 6.7 20.1 rOTAL 1 20.11 RIGHT GLAZING W H AREA 5.0 5.0 25.0 7.0 5.0 35.0 u 1.28 1.28 SC 0.99 0.99 60.01 1.281 0.99 ,-f Engineering Incorporated 1 1404 156 1784 9.0 WEST LA QUINTA 112 24 N/A 1981 20th Anniversary 2001 Consulting Electrical Engineers 19031 77 zhy� x> 18 $ft. 200 72.330 <wVD l aue Apple V.Uey, CA 92307 Palm D—n t, CA 92260 Pb—: (760) 242-3369 Phuuc: (760) 773-4478 Fax: (766)242-1092 Fax: (760)242-IO92 - drearo)ne�aleheler.�M dRwnjua�r)auLcum FORM J EQUIPMENT LOADS PROJECT: 22 BTU/SQ FT DREAM ENGINEERING INC. 72330 CANYON LANE COMPTON RESIDENCE 1784 SQ FT PALM DESERT, CA (760)773-4478/F242-1092 LA QUINTA CA HTM HTM • AREA/ BTU BTU NUMBER OF FLOORS CLG HTG LENGTH CLG HTG EXPOSED WALL (SQ FT) GROSS EXPOSED WALLS FOOTPRINT - PERIMETER (FT) FIXED WINDOWS 34 0 0 0 BUILDING DIMENSIONS (SQ FT) SLIDING WINDOWS 35 187 0 6452 CEILING HEIGHT (FT) WINDOWS & NORTH 30 22 648 DIRECTION FACING GLASS DOORS: EAST 80 80 6432 LOCATION SOUTH 45 60 2700 SUMMER DESIGN OUTDOOR - 78 WEST 80 _ 25 2000 WINTER DESIGN OUTDOOR - 68 SKY LIGHTS 0 48 0 0 0 UBC 50% OCCUPANCY OPAQUE DOORS 38 25 40 1520 1000 DISCLAIMER: NET EXPOSED WALL R13 2.5 2.6 1404 3510 3650 1.THE BUILDING HEAT LOSS & RESULTING MAXIMUM HEATING AVE CEILINGS R38 2.460 2.53 1784 4388 4506 EQUIPMENT OUTPUT CALCULATIONS IN THIS REPORT MEET THE CEILINGS (R#2) 0 0 CRITERIA OF TITLE 24. THIS MAXIMUM MAY BE EXCEEDED FLOOR (SLAB - PERIMETER) 0 28 156 0 4415 WHEN THE FURNACE IN THE SELECTED PRODUCT LINE MUST BE FLOOR (RAISED FLOOR) 0 0 0 0 LARGER TO MEET COOLING LOAD AIR FLOW REQUIREMENTS. SUBTOTAL BTUH LOSS 20023 23HE BUILDING SENSIBLE HEAT GAIN CALCULATED IN THIS DUCT BTUH LOSS (15%) 2403 REPORT MEETS THE CRITERIA OF TITLE 24 AND MAY BE HEATING: TOTAL BUTH LOSS 22425 USED BY THE MECHANICAL CONTRACTOR IN EQUIPMENT PEOPLE & APPLIANCES 1200 SELECTION AND SYSTEM DESIGN. THE ARI STANDARD 210 SENSIBLE BTU GAIN 22398 RATED CAPACITY OF THE EQUIPMENT SELECTED MAY NEED DUCT BTU GAIN (15°x) 3360 TO BE HIGHER THAN THAT STATED IN THE CALCULATIONS SUM OF SENSIBLE AND DUCT GAINS 25758 BECAUSE THE DESIGN CONDITIONS FOR THE LOCATION ARE COOLING: TOTAL BTUH GAIN (TOTAL X 1.3) 33485 DIFFERENT FROM THE TEST CONDITIONS USED IN THE RATINGS. HTG UNIT SIZING = BTUH LOSS X 1.3 + 10 X AREA = 46991 BTU HEATING OUTPUT, MINIMUM REQUIRED CLG UNIT SIZING = BTUH GAIN X 1.15 = 38508 BTU COOLING SENSIBLE, MINIMUM REQUIRED 3 TON 1 1404 156 1784 9.0 WEST LA QUINTA 112 24 N/A