11260 (SFD)P.O. BOX 1504 N o . 11260
Building 52-990 CarraAxa 78-105 CALLE
Address LA QUINTA, CALIFORNIAORNIA 92253
Owner
David Miller
Mailing
Addressp. Q. Box 722
City Zip Tel.
LaQuinta 1 92253
Contractor
Pacific Trades
Address
same as above
City Zip Tela
State Lic. Lic.
&# 1955
Classif. 13425381
Arch., Engr., I
Designer
Address I Tel.
City ` (Zip (State I
Lic. #
, LICENSED CONTRACTOR'S DECLARATION
1 hereby affirm that 1 am licensed under provisions of Chapter 9 (commencing with Section
7000) of Division 3 of the Business and Professions Code, and my license is in full foand
effect. - rce '!
SIGNATURE DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a
permit to construct, after, Improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to rile a signed statement that he is licensed pursuant to
the provisions of the Contractor's license Law. Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars f$500).
❑ I, as owner of the property, or my employees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or improves thereon and who does such work himself or through his own employees,
provided that such improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of completion, the owner -builder will have the burden
of proving that he did not build or improve for the purpose of sale.)
❑ I, as owner of the property, am exclusively contracting with licensed contractors to con-
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of property who builds or improves thereon, and who contracts for
such projects with a contractor(s) licensed pursuant to the Contractor's License Law.)
O 1 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm'that I have a certificate of consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
Copy is filed with the city. ❑ Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed i1 the permit is for one hundred dollars ($100) valuation
or less.)
I certify that in the performance of the work for which this permit is issued, I shall not
employ any person in any manner so as to become subject to the Workers' Compensation
Laws of California.
Date Owner
NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions or the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives -of this city to enter the above-.
mentioned property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
BUILDING: TYPE CONST. OCC. GRP.
A.P. Number 773-322-013
Legal Description Lot 14, Block 157
Project Description
SF'D
Sq. Ft.;257
Size
No.
Stories
No. Dw.
Units
New ❑ Add ❑
Alter ❑ Repair ❑ Demolition ❑
Permit does
not include
any block walls
or pool
Estimated Valuation
75:339.70
PERMIT
AMOUNT
Plan Chk. Dep.
250.00
Plan Chk. Bal.
208.61
Const.
531.50
Mech.
55.50
Electrical
117.02
Plumbing
141.00
S.M.I.
7.50
Grading
20.00
Driveway Enc.
.00
Infrastructure
1695.1:
TOTAL
30/--1. 1!2
z F77-. 15
REMARKS
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by: Date Permit
Validated by:
Validation:
CONSTRUCTION ESTIMATE
NO. ELECTRICAL FEES
NO. PLUMBING FEES
1ST FL. SQ. FT. ® $
2ND FL. SQ. FT.
FOR. SO. FT. ®
GAR. SO. FT. ®
CAR P. SD. FT.
WALL SQ. FT.
SO FT ®
ESTIMATED CONSTRUCTION VALUATION $
UNITS
MOBILEHOME SVC.
POWER OUTLET
YARD SPKLR SYSTEM
BAR SINK
ROOF DRAINS
DRAINAGE PIPING
DRINKING FOUNTAIN:)
URINAL
WATER PIPING
NOTE: Not to be used as property tax valuation
SLAB GRADE
FLOOR DRAIN
MECHANICAL FEES
BONDING
WATER SOFTENER
VENT SYSTEM FAN EVAP.COOL HOOD
SIGN
WASH ER(AUTO)(DISH)
APPLIANCE DRYER
SEWER OR SEPTIC TANK
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
DUCT WORK
LAUNDRY TRAY
AIR HANDLING UNIT CFM
KITCHEN SINK
ABSORPTION SYSTEM B.T.U.
TEMP USE PERMIT SVC
WATER CLOSET'
COMPRESSOR HP
POLE, TEM/PERM
LAVATORY
HEATING SYSTEM FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER, B.T.U.
SQ. FT. ® c
BATH TUB
SQ. FT. ® c
WATER HEATER
MAX. HEATER OUTPUT, B.T.U.
SQ. FT. RESID ® 1% c
SEWAGE DISPOSAL
BOND BEAM
SQ.FT.GAR ® 3Ac
HOUSE SEWER
FINAL INSP. A
__/
GAS PIPING
PERMIT FEE
PERMIT FEE
PERMIT FEE
DBL
TOTAL FEES
MICRO FEE
MECH.FEE PL.CK.FEE
CONST. FEE ELECT. FEE
SMI FEE PLUMB. FEE
STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR '
SETBACK
GROUND PLUMBINGd;eg
J UNDERGROUND
A.C. UNIT
COLL. AREA
SLAB GRADE
ROUGH PLUMB.
BONDING
HEATING (ROUGH)
STORAGE TANK
FORMS
SEWER OR SEPTIC TANK
ROUGH WIRING.
DUCT WORK
ROCK STORAGE
FOUND. REINF.
GAS (ROUGH)
METER LOOP
HEATING (FINAL)
OTHER APPJEOUIP.
REINF. STEEL
GAS (FINAL)
TEMP. POLE ` l/
!o 40
�v�
GROUT
WATER HEATER
SERVICE
FINAL INSP.
BOND BEAM
WATER SYSTEM
FINAL INSP.
FINAL INSP. A
__/
GRADING
cu. yd.
$ plus x$
_$
LUMBER GR.
FRAMING ! i�
[[
ROOFING
Q
L
�� av,0 G ' ✓/ h
7
jg
aa Y
1
gt 3
REMARKS:
VENTILATION
FIRE ZONE ROOFING
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL
Uw
THING a Ll
MESH
INSULATIONISOUND IS
6 FINAL INSPECTION
CERT. OCC.
FENCE FINAL
INSPECTOR'S SIGNATURESIINITIALS
GARDEN WALL FINAL
DESERT SANDS UNIFIED SCHOOL DISTRICT
82-879 Highway 111
NOTICE: Indio, CA 92201
Document Cannot Be Duplicated (619) 347-8631
Date 8/10/92 1 Type of Permit I La Quinta
No. 11631 Permit #
Log #
Owner Name David Miller
No. 52990 street Carranza
city La Quinta zip 92253
Study Area 112
APN #
Tract # I
Lot #
Square Footage
11257
Type of Development
No. of unite
0
Single Family Residence
Comments
At the present time, the Desert Sands Unified School District does not collect fees on
garages/carports, covered patios/walkways, residential additions under 500 square feet,
detached accessory structures or replacement mobilehomes. It has been determined
the above-named owner is exempt from paying school fees at this time due to the
following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to Government Code 53080
in the amount of 1.58 X 11.2577 or $ 1,986.06 have been paid to D.S.U.S.D. for
the property listed above and that building permits and/or Certificates of Occupancy for
this square footage in this proposed project may now be issued.
Fees Paid By David R. Miller Telephone %
Name on the check
By James E. Lively
Assistant Superintendent, Business Services
Fee collected /exempted by Shelley D. Bennett
Payment R'
ceiv
` ed,
,
Signature
Check No. 1*4.18
Collector: Attach a copy of county or city plan check application form to district copy,fur ail w''aivers.
Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting
DATE b
OFFICE OF
AGRICULTURAL COMMISSIONER
JAMES O. WALLACE, Commissioner
83-612 Avenue 45 Suite 7
Indio, CA 92201
(619) 342-8291
CASE NO.? C C '�3 ( ,D 9D - 3
DEVELOPER'S NAME:
ADDRESS:
TELEPHONE:
Dear Developer:
After reviewing your landscaping plans, all plant material listed is not in
violation of quarantine laws governing the Coachella Valley. If substitutions
do occur and they differ from plant material listed, this office must be notified
immediately.
Thank you for protecting and preserving the Coachella Valley's pest -free environment.
Agricult alCommissioner's Office
cc: Indio and Riverside
4080 LEMON STREET, ROOM 19, RIVERSIDE, CALIFORNIA 92,501 - FAX (714) 275-3012
0
CALVIN C. KAMINSKAS
;t's DAN RILEY
Assistant Commissioner
} ° Sealer, Weights & Measures
(714) 275-3000
e
(714) 275-3030
;r. ,''�
DATE b
OFFICE OF
AGRICULTURAL COMMISSIONER
JAMES O. WALLACE, Commissioner
83-612 Avenue 45 Suite 7
Indio, CA 92201
(619) 342-8291
CASE NO.? C C '�3 ( ,D 9D - 3
DEVELOPER'S NAME:
ADDRESS:
TELEPHONE:
Dear Developer:
After reviewing your landscaping plans, all plant material listed is not in
violation of quarantine laws governing the Coachella Valley. If substitutions
do occur and they differ from plant material listed, this office must be notified
immediately.
Thank you for protecting and preserving the Coachella Valley's pest -free environment.
Agricult alCommissioner's Office
cc: Indio and Riverside
4080 LEMON STREET, ROOM 19, RIVERSIDE, CALIFORNIA 92,501 - FAX (714) 275-3012
0
Cf, -- -
--- - - - - -- - - - - --
FINNELL COMPANY 714659.961 P.02
COMPUTER METHOD SUMMARY Page 1 C -2R
Project Title.......... PACIFIC Date., .. 06/30/92
Project, Address........ LA OUINTA---------------------
Documentation Author... W J FINNELL
Company................. ENERGY CONSULTING GROUP
Telephone .............. 800-262-9966
Building Permit #
Plan Check / Date
Compliance Method...... MICROPAS3 by Enercomp, Inc. ; Field Check/ Date
Climate Zone........... 15 ---------------------
--------------------------------------------------
MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM C -2R ,
User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC
-------------------------------------------------------------------------------
MICROPAS3 ENERGY USE SUMMARY
= Energy Use
Standard
Proposed
Compliance =
- (kBtu/sf-yr)
Design
Design
Margin -
Space Heating..........
6.55
2.92
3.63 =
= Space Cooling..........
47.56
42,38
5.18 -
= Water Heating..........
14.88
21.97
-7.09 -
= Total
68.99
67.27
1.72 =
_* Building complies
with Computer
Performance**
GENERAL INFORMATION
-------------------
Conditioned Floor Area.....
Building Type.... .....:....
Building Front Orientation.
Number of Dwelling Units...
Number of Building Stories.
Weather Data Type..........
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Footprint Area .........:...
Slab -On -Grade Area.........
Glazing Percentage.........
Average Ceiling Height.....
zone Type
--------------
HOUSE
Residence
1257 sf
Single Family detached
Front Facing 270 deg (W)
1 '
1
ReducedYear
Slab On Grade
10936 cf
1257 sf
1257 sf
10.8 % of FA
8.7 ft
(Package D)
BUILDING ZONE
INFORMATION
-------------------------
Floor
# of
Cond- Area Volume
Dwell Thermostat
itioned (sf) (cf)
Units Type ;.
Yes 1257 10936
1.00 Setback
Vent Special
Height Vent Area
(ft) (sf)
2.0 n/a
FINNELL COMPANY 7146593961
P.03
COMPUTER
METHOD SUMMARY
Page
2
C -2R
Project
Titie......,...
PACIFIC
- -------------------------Date
........ ----06/30/82
MICROPAS3 v3.11 File -PACIFIC
Wth-CTZ15 Program -FORM
C -2R
--------------------------------------------------------------------------------
User#-MP1325 User -ENERGY
CONSULTING GROUP Run -PACIFIC
'
OPAQUE SURFACES
Area
U- Insul
---------------
Act
Solar Location/
Form
3
Surface
(sf)
value R-val
Azmth
Tilt Gains Comments
Reference
HOUSE
1 Wall
64
0.065 R-19
270
90 Yes OUTSIDE
None
2 Wall
160
0.065 R-19
270
90 No GARAGE
None
3 Wall
252
0.065 R-19
0
90 Yes OUTSIDE
None
4 Wall
198
0.065 R-19
90
90 Yes OUTSIDE
None
5 Wall
.204
0.065 R-19
180
90 Yes OUTSIDE
None
6 Roof
1257
0.029 R-38
0
0 Yes ATTIC
None
7 Door
20
0.330 R-2
270
90 Yes OUTSIDE
None
PERIMETER LOSSES
Length
----------------
F2
Insul
Surface
------------
(ft) Factor
R-val Location/Comments
HOUSE
------- --------
------- ----------------------
8 SlabEdge
9 0.900
R-0 TO OUTSIDE
9 SlabEdge
116 0.720
R-0 TO OUTSIDE
10 SlabEdge
20 0.550
R-0 TO GARAGE
GLAZING
SURFACES
----------------
SC
Interior SC
Area #
of Frame
Open
U- Act Glass
Shade
GIs+
Surface
(sf) Panes Type
Type
value Azmth Tilt Only
Type
Shade
HOUSE
1 Window 26.0
2 Metal
Slider
0.65 270 90 0.77
drapes
0.66
2 Window 16.0
2 Metal
Slider
0.65 .0 90 0.77
drapes
0.66
3 Window 49.0
2 Metal
Slider
0.65 90 90 0.77
drapes
0.66
4 Window 45.0
2 Metal
Slider
0.65 180 90 0.77
drapes
0,66
EXTERIOR
----------------
SHADING
Area
Shading SC of
Surface
(sf)
Type Ext Shade
HOUSE
I
Window
26.0
50% bug scrn 0.84
2
Window
16.0
50% bug scrn 0.84
3
Window
49.0
50% bug scrn 0.84
4
Window
45.0
50% bug scrn 0.84
----------------------------------------------------------------------------- ---
FINNELL COMPANY 7146593961 P.04
COMPUTER METHOD SUMMARY Page 3 C -2R
Project.Title..... I.... PACIFIC ------- ---------Date ........ ~06/30/92
----------
MICROPAS3 v3.11 File -PACIFIC Wth-CTz15 Program -FORM C -2R
User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC
-------------------------------------------------------------------------------
THERMAL MASS
HVAC SYSTEMS
Area
Thick
Heat
Conduct-
Surface
Efficiency
------------
Mass Type
---------------
(sf)
------
(in)
-----
Cap
-----
ivity
--------
R -value
--------
Location/Comments
--------------------------
HOUSE
HeatPump
8.0 HSPF
Attic
R-5
0.828
AirCond
1 SlabOnGrade
210
3.5
28.0
0.98
R-0
KIT/BATHS
2 SlabOnGrade
1047
3.5
28.0
• 0.98
R-2
REST OF HOUSE
3 InteriorHorz
54
1.0
24.0
0.6T
R-0
TILE: BATHS/KITCHEN
4 InteriorVert
72
4.0
21.0
0.59
R-0
FIREPLACE
HVAC SYSTEMS
WATER HLATING SYSTEMS
---------------------
Minimum
Duct
Duct
Duct
System Type
----------------
Efficiency
------------
Location
-------------
R -value
-------
Efficiency
----------
HOUSE
(Btuh) Credits
Storage
HeatPump
8.0 HSPF
Attic
R-5
0.828
AirCond
10.00 SEER
Attic
R-5
0.818
WATER HLATING SYSTEMS
---------------------
SPECIAL FEATURES/REMARKS
-----------------------
Capa-
R-12 or
Pilot
System
# of city
Greater Effic- Standby Input
Size
Type
Heat (gal)
Blanket iency Loss Rating
(Btuh) Credits
Storage
Flectric
1 37
No 0.99 RE .82% 4.5 kW
n/a Recovery
SPECIAL FEATURES/REMARKS
-----------------------
WATER HEATING Page 1 DHW
Project Title.......... PACIFIC Date. -
Project Address........ LA QUINTA-------------06/30/92
Documentation Author... W J FINNELL
Building Permit #
Company ................ ENERGY CONSULTING GROUP
Telephone .............. 800--262-9966 1 Plan Check / Date
Compliance Method...... MICROPAS3 b Enercom Inc.
Y p, ; Field Check/ Date
Climate Zone........... 15 -------------------
1 MICROPAS3 v3.11 File-PACIPIC Wth-CTZ15 Program -WATER HEATING
User#-MP1325 User -ENERGY CONSULTING GROUP Run-PACIFIC-------------------------------------------------------------------------------
;
WORKSHEET ONE: STORAGE GAS OR STORAGE ELECTRIC
A. EQUIPMENT DATA
-----------------
1. Water heater type.......
2. Manufacturer............
3. Model number............
4. Ignition device.........
5. Tank volume .............
6. Recovery efficiency.....
7. Standby loss...........
8. Rated Input .............
9. Number of Heaters.......
10.Insuiation jacket.......
Storage, Electric
n/a
37 gal
.99 percent x 0.01
.0082 percent/hour x 0.01
15358.5 Stu/hr
1
No
B. OPERATING DATA
-----------------
1. Climate Zone.. .......
2. Water heating budget....
3. Tank set temp...........
4. Water main temp.........
5. Daily hot water load....
6. Ambient air temp........
7. Adj.. Standby Losses.....
8. No. dwelling units.......
9. Pump power ..............
10 -Pumping energy..........
15
18700 kBtu/yr/unit
140 F
70 F
50 gal
72.6 F
.0082
1
0 Watts (0 Watts controller)
0 Watt-hr/yr (0 hr. per day)
C. WATER HEATING ENERGY CREDITS
-------------------------------
1. Credit Name ............. Recovery
2. Annual savings.......... 2805 kBtu/yr/unit
D. ANNUAL WATER HEATING
ENERGY
1.
------------------------------
Recovery load............
10539
kBtu/yr
2.
Recovery energy.........
7813
kBtu/yr
3.
Standby loss energy.....
1392
kBtu/yr
4.
Pumping energy..........
0
kStu/yr source
5.
Total energy............
27614
kBtu/yr/unit source
6.
Comparison ..............
-8914
k8tu/yr/unit source
7.
Points... .............
-14
8.
Water Heating Energy Use
21.97
k8tu/yr/sf
(D5 x 68) / 1257 sf
HVAC SIZING Page 1 HVAC
Project Title...... ... PACIFIC - -- M~- ------"Date ........ 06/30/92
Project Address........ LA QUINTA---------------------
Documentation Author... W J FINNELL
Company ................ ENERGY CONSULTING GROUP
Telephone .............. 800-262-9966
Building Permit #
Pian Check / Date
Compliance Method...... MICROPAS3 by Enercomp, Inc. Field Check/ Date ;
Climate Zone........... 15
MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -HVAC SIZING ,
User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC ;
------------------------------------------------------------------------------
GENERAL INFORMATION
Floor Area ................. 1257 sf
Volume ..................... 10936 cf
Front Orientation.......... Front Facing 270 deg (W)
Sizing Location............ INDIO
Latitude.... .... ....... 33.7 degrees
Winter Outside Design...... 29 F
Winter inside Design....... 70 F
Summer Outside Design...... 112 F
Summer Inside Design....... 78 F
Summer Range ............... 30 F
Shading Used ............... No
Latent Load Fraction....... 0.20
HEATING AND COOLING LOAD SUMMARY
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outdoor design temperatures, coil sizing, availability of
equipment, oversizing safety margin, etc., must also be considered. It is
the HVAC designer's responsibility to consider all factors when selecting
the HVAC equipment.
CEC Maximum output applicable for gas central furnaces only
Heating
Cooling
Description
(Btuh)
.(Btuh)
Opaque Conduction and Solar......
8312
3918
Glazing Conduction ...............
3624
3006
Glazing Solar ....................
n/a
5509
Infiltration .....................
6449
3822
Internal Gain ....................
n/a
2550
Ducts... ..........................
1839
1880
Sensible Load ....................
20224
20685
Latent Load .......................
n/a
4137
Total Load
20224
24822
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outdoor design temperatures, coil sizing, availability of
equipment, oversizing safety margin, etc., must also be considered. It is
the HVAC designer's responsibility to consider all factors when selecting
the HVAC equipment.
CEC Maximum output applicable for gas central furnaces only
------------------------------------------------------------------
FINNELL COMPANY 7146593961 P.07
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R
Project Title.......... PACIFIC Date........ 06/30/92
Project Address........ LA QUINTA---------------------
Documentation
--------- --Documentation Author... W J FINNELL Building Permit # ;
Company ................ ENERGY CONSULTING GROUP ;
Telephone .............. 800-262-9966 ; Plan Check / Date ;
Compliance Method...... MICROPAS3 by Enercomp, Inc. ; Field Check/ Date
Climate Zone........... 15 ---------------------
MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM CF -1R ,
User#-MP1325 User -ENERGY CONSULTING GROUP Run-PACIFIC
---------------------------------------------------------------------------------
GENERAL INFORMATION
Conditioned Floor Area..... 1257 sf
Building Type .............. Single Family Detached
Building Front Orientation. Front Facing 270 deg (W)
Number of Dwelling Units... 1
Number of Stories.......... 1
Floor Construction Type.... Slab On Grade (Package D)
Infiltration Control....... Standard
BUILDING SHELL INSULATION
-------------------------
Component Insul
Type R -value Location/Comments
Wall R-19 OUTSIDE, GARAGE
Roof R-38 ATTIC
Door R-2 OUTSIDE
SlabEdge R-0 TO OUTSIDE, TO GARAGE
GLAZING
Glazing Area # of Interior Exterior Framing
Orientation (sf) Panes Shading Shading Overhang Type
Window Front (W) 26.0 2 drapes 50% bug scrn None Metal
Window Left (N) 16.0 2 drapes 50% bug scrn None Metal
Window Back (E) 49.0 2 drapes 50% bug scrn None metal
Window Right (S) 45.0 2 drapes 50% bug scrn None Metal
THERMAL MASS
------------
Area Thickness Hard Surfaced/
Type (sf) (in) Exposed Location/Comments
------------ ----------------------------- ------------------------
SlabOnGrade 210 3.5 Yes KIT/BATHS
S1abOnGrade 1047 3..5 No REST OR HOUSE
InteriorHorz 54 1.0 Yes TILE: BATHS/KITCHEN
InteriorVert 72 4.0 Yes FIREPLACE
f,.
--------------
FINNELL COMPANY 714659.961 P.08
CERTIFICATE OF COMPLIANCE: RESIDENTIAL. Page 2 CF -1R
Project^Title .......... PACIFIC Date ........ 06/30/92
MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM -CF -1R -^
User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC
-------------------------------------------------------------------------------
ASSUMED HVAC SYSTEMS
Assumed
Duct
Duct
Assumed System Efficiency
Location
R -value
HeatPump 8.0 HSPF
Attic
R-5
AirCond 10.00 SEER
Attic
R-5
Actual System
---------------
Heating
Cooling
Cooling Coil
ACTUAL HVAC SYSTEMS
-------------------
Actual Output Manufacturer and Model #
Efficiency (Stuh) (or approved equal)
CEC Maximum output for Gas Central Furnaces: Btuh
WATER HEATING SYSTEMS
---------------------
Tank R-12 or
# of Vol Greater Manufacturer and Model # Energy
System Type Heat (gal) Blanket (or approved equal) Credits
Storage, Electric 1 37 No Recovery
SPECIAL FEATURES/REMARKS
FINNELL COMPANY 7146593961 P.09
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R
Project Title.......... PACIFIC Date........ 06/30/92
MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM CF -1R
User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC ;
-------------------------------------------------------------------------------
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications needed to comply with Title 24, Chapter 2-53 and Title 20,
Chapter 2, Subchapter 4, Article 1 of the California Administrative code.
This certificate has been signed by the individual with overall design
responsibility and the building owner, who shall retain a copy of it and
transmit the certificate to any subsequent purchaser of the building. When
this certificate of compliance is submitted for a single building plan to
be built in multiple orientations, all building conservation features
which vary are indicated in the Special Features/Remarks section.
DESIGNER
Name....
Company.
Address.
Phone...
License.
Signed
(date)
DOCUMENTATION AUTHOR
Name.... W J FINNELL
Company. ENERGY CONSULTING GROUP
Address. 34F INDIAN HILLS
MTN CENTER, CA 92561
Phone... 800-262-9966
WNER O
Name.... C_V70
Company
Address.
Phone...
signed
(date)
ENFORCEMENT AGENCY
Name....
Title...
Agency..
Phone...
r'
Signed Z Signed
(date)
(date)
FINNELL COMPANY
-------------
7146593961
P.10
MANDATORY MEASURES CHECKLIST. RESIDENTIAL Page 1 MF -1R
-------------------------------------------------------------------------------
Project Title.......... PACIFIC Date........ 06/30/92
Project Address........ LA QUINTA---------------------
Documentation Author... W J FINNELL
Company ................ ENERGY.CONSULTING GROUP
Telephone .............. 800-262-9966
Building Permit #
Plan Check / Date
Compliance Method...... MICROPAS3 by Enercomp, Inca ; Field Check/ Date ;
Climate Zone........... 15 ---------------------
MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM MF -1R
User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC ;
-------------------------------------------------------------------------------
Lowrise residential buildings subject to the Standards must contain these
measures regardless of the compliance approach used. items marked with an
asterisk (*) may be superseded by more stringent compliance requirements listed
on the Certificate of Compliance. When this checklist is incorporated into the
permit documents, the features noted shall be considered by all parties as
binding minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
--------------------------
Design- Enforce-
er ment
* 2-5352(a): Minimum ceiling insulation R-19 weighted average.
2-5352(b): Loose fill insulation manufacturers labeled R -Value.
2-5352(c): Minimum wall insulation in framed walls R-11.
weighted average (does not apply to exterior mass walls).
2-5352(k): Slab edge insulation - water absorption rate no
greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch.
2-5311: Insulation specified or instal ' led meets CEC quality
standards. Indicate type and form.
2-5352(f): Vapor barriers mandatory in Climate Zones 14 and 16.
2-5317: Infiltration/Exfiltration Controls
a. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage.
b. Doors and windows certified.
c. Doors and windows weatherstripped; all joints and
penetrations caulked and sealed.
2-5352(e): Special infiltration barrier installed to
comply with Sec. 2-5351 meets CEC quality standards.
2-5352(d): installation of Fireplaces
1. Masonry and factory -built fireplaces have:
a. Tight fitting, closeable metal or glass door*
b. Outside air intake with damper and control
FINNELL COMPANY
7146593961
MAN-DATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF -1R
Project Title.......... PACIFIC Date........ 06/30/92
MICROPAS3 v3.11 File -PACIFIC Wth-CTZ15 Program -FORM MF -1R
User#-MP1325 User -ENERGY CONSULTING GROUP Run -PACIFIC ;
-------------------------------------------------------------------------------
HVAC AND PLUMBING SYSTEM MEASURES
---------------------------------
Design- Enforce-
er ment
2-5352(8) and 2-5303: Space conditioning equipment sizing:
attach calculations.
2-5352(h) and 2-5315: Setback thermostat on all applicable
heating systems..
* 2-5316(a): Ducts constructed, installed and insulated per
Chapter 10, 1976 UMC.
2-5316(b): Exhaust systems have damper controls.
2--5314(c): Gas-fired space heating equipment has
intermittent ignition devices.
2-5314: HVAC equipment, water heaters, showerheads and
faucets certified by the CEC.
2-5352(i): Water heater insulation blanket (R-12 or greater) for
storage and backup tanks for.so.lar water heating systems (first
5 feet of pipes closest to tank insulated to R-3 or greater).
2-5312(Exception 1): Pipe insulation on steam and steam
condensate return and recirculating piping.
2-5318(d): Swimming Pool Heating
1.. System has:
a. On/off switch on heater.
b. Weatherproof instruction plate on heater.
c. Plumbed to allow for solar.
2. 75 percent thermal efficiency.
3. Pool cover.
4. Time clock.
S. Directional water inlet.
LIGHTING AND APPLIANCE MEASURES
-------------------------------
Design- Enforce-
er ment
2-5352(j): Lighting - 25 lumens/watt or greater for
general lighting in kitchens and bathrooms.
2-5314(c): Gas fired appliances equipped with
intermittent ignition devices.
2-5314(a): Refrigerators, refrigerator -freezers,
freezers and fluorescent lamp ballasts certified by the CEC.
COASTAL COUNTIES ESCROW
74-350 ALESSANDRO, SUITE A-2
PALM DESERT, CALIFORNIA 92260
(619) 340-2592
SALE ESCROW INSTRUCTIONS
TO: COASTAL COUNTIES ESCROW
DATE: May 06, 1992
ESCROW NO: 4857-J
ESCROW OFFICER: Jackie Feldman.
PROPERTY ADDRESS: (to be determined)
La Quints, CA 92253
;Cash through escrow...... $ 21,580.00
.New Encumbrance - lst TD $ 86,320.00
;Total Consideration...... $ 107,900.00
On or before 07/20/92, I will hand you, or rause to be handed you, the sum of
$21,580.00, of which the sum of $1,000.00 has been handed the broker for deposit
herein
and will deliver to you any instruments executed by me that are called for below, and
any additional funds to enable you to comply with these instructions: all. of which
together will equal the total consideration herein of $107,900.00, which you shall
deliver when you can obtain a Grant Deed to the hereinafter described property and a
C.L.T.A. Standard Form Policy of Title Insurance with liability equal to the total
consideration herein, on the following described real property in the State of
California, County of Riverside, being:
Lot .14 in block. 157 of Santa Carmelita at Vale La Qui.nta, Unit No. 16, as per map
recorded in Book 18, page 99 of Maps in the office of the County Recorder of said
County.
Showing title vested in:
Rory N. Horton, a single man and Stacey E. Gralund, a single woman (vesting to be
determined in escrow)
SUBJFCT ONLY TO:
A) All of the instillment(s) of General and Special County Taxes, assessments
of any governmental body, including district levies, payments of which are included
and collected therein, for current fiscal year, not delinquent, including taxes for
the ensuing year, a lien not -payable.
B) Covenants, conctLtions, restrictions, easements, rights of: way and the exception
and reservation of any oil, gas, water and hydrocarbon subst-ances, on or under said
land, now of record and/or reserved in deed to file, if any, affecting the rrse and
occupancy of said .land.
C) Borrower to apply and qualify for a new First Trust Decd in the amount of
$86,.320.00 bearing interest_ at -the prevailing rate, payable monthly per lenders terms
and (,-�nditions.
Borrowers execut::ion of. :lenders lean documents shall. be deeivd their approval of the
terms and condilions contained therein.
Ek -a -rower agrees to furnish insurance coverage per lenders requirements and escrow
holder is instrr.rcted to pay premium for same from borrowers deposit into escrow.
Escrow holder is instn.rct:ed to hand lender any supporti n.) documentation as required
by lender in order for borrower to obtain said loan.
f1) Any bonds or assessrm2rits with the exception of the sewer are to be paid current by
sc,.l..l.er and assruned by buyer.
TNS'1'Kt1CTIONS :
BUYER to approve or disapprove the Preliminary Title Report within 3 days of receipt
of same from escrow.
SELLER(s) agree to hand escrow holder a duly executed 1099/1.096 information
Authorization for the report of Real Estate Transaction in accordance with Tnternal
Revenue Code Section 6045(e). B11Yt'R and SELLER are aware the closing of this escrow
may he delayed until such time as SELLER has complied with the 1987 Tax Reform Act as
set fc)r.t.h herein.
Sewer to be hooked up by seller at close of escrow and inc-luded in the 1.A.rrchase
price.
Seller to receive from buyer in escrow a pre -qualification letter from lender of
choice within 10 days of acceptance.
The purchase price will. be amended based on "Premium" Tot choice.
III
of
. )'rrT_r16&
licu
TiN of 14a,
(Quinta
jluitbtn� anb s`safet� 34t*11t*rm*Vn
This Certificate issued pursuant to the requirements of Section 306 of the Uniform Building
Code certifying that at the time of issuance this structure was in compliance with the various
ordinances of the City regulating building construction or use. For the following:
BUILDING ADDRESS 52-99.0 AVENIDA CARRANZA
Use Classification SINGLE FAMILY DWELLING Bldg. Permit No. 11260
Group R3 Type Construction VN Fre Zone Use Zone SR
Owner of Building DAVID MILLER Address P • 0. BOX 722
City LA QUINTA, CA 92253 LONNIE DAY
By;
Dote; OCTOBER .13, 1992
Building Official
POST IN A CONe?ICUOU! PLACE
11
Department of Building & Safety
CITY OF LA QUINTA
T0: Date:
ADDRESS:
Permit No.
N
CORRECTION NOTICE
3 ) 14ol- 4Ja7e r �-eca u4 /Le S:. iy -- . SL1-1J�
P.O. BOX 1504 APPLICATION ONLY
Building Z _ Ct U v (,�\ �� 7&105 CALLE ESTADO �j
C
Address 1 LA QUINTA, CALIFORNIA 92253 �0�%�� .
Owner
MailingBUILDING: TYPE CONST
Address e • v • e tr
A.P. Number
City j ir, l Zip Tel.
�C >�—_ Legal Description
Contractee -i , \ �;, �� �� Project Description / f1
Address 1 r \
City lZip Tel.
OCC. GRP
State Lic. ? Z t, 3 6 I City
& Classif. `meq Lic. #
Arch., Engr.,
Designer
Address Tel.
City Zip State
Lic. #
LICENS%l CONTRACTOR'S DECLARATION
�he %b ,affirm t¢ai,l�am license under�ovisions�of Chapter 9 (comencing`w��th Section
of�I i io0, he.PG{inessLapd Professions Code, and my Ijcen a is in I force and
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a
permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to rile a signed tstafement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis
for the alleged exemption. Any violation or Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).
l-; I, as owner of the property, or my employees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or improves thereon and who does such work himself or through his own employees,
provided that such improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of completion, the owner -builder will have the burden
of proving that he did not build or improve for the purpose of sale.)
I 1 I, as owner of the property, am exclusively contracting with licensed contractors to con-
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of property who builds or improves thereon, and who contracts for
such projects with a contractor(s) licensed pursuant to the Contractor's License Law.)
(l I am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
n Copy is filed with the city. O Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars (3100) valuation
or less.)
I certify that in the performance of thg work for which this permit is issued, 1 shall not
employ any person in any manner so as to become subject to the Workers' Compensation
Laws of California.
Date Owner
NOTICE TO APPLICANT., If, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions or the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives -of this city to enter the above-
mentioned property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
BUILDING DIVISION
Sq. Ft. No. No. Dw.
Size Stories Units
New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑
Estimated Valuation
PERMIT AMOUNT
Plan Chk. Dep.
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
S.M.I.
Grading
Driveway Enc.
Infrastructure
fi
TOTAL
REMARKS
ZONE:
BY:
Minimum Setback
Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE
INSPECTOR
Issued by:
Date Permit
Validated by:
Validation:
STRUCTURE / PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
SETBACK
GROUND PLUMBING
V-,
CONSTRUCTION ESTIMATE
NO. ELECTRICAL FEES
NO. PLUMBING FEES
1ST FL. SO. FT. @ $
UNITS
HEATING (ROUGH)
2ND FL, SO. FT. @
FORMS
YARD SPKLR SYSTEM
POR. SO. FT. @
MOBILEHOME SVC.
BAR SINK
GAR. SO. FT. @
POWER OUTLET
ROOF DRAINS
CAR P. SO. FT. @
METER LOOP
DRAINAGE PIPING
WALL SO. FT. @'
REINF. STEEL
DRINKING FOUNTAIN
SO. FT. @
URINAL
ESTIMATED CONSTRUCTION VALUATION $
WATER HEATER'
WATER PIPING
NOTE: Not to be used as property tax valuation
FLOOR DRAIN
MECHANICAL FEES
WATER SOFTENER
VENT SYSTEM FAN EVAP.000L HOOD
t SIGN
WASHER(AUTO)(DISH)
APPLIANCE DRYER
FRAMING
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
ROOFING
LAUNDRYTRAY
AIR HANDLING UNIT CFM
KITCHEN SINE;
ABSORPTION SYSTEM. B.T.U.
TEMP USE PERMIT SVC
WATER CLOSET
COMPRESSOR HP
POLE, TEMIPERM
LAVATORY
HEATING SYSTEM FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER B.T.U.
SO. FT. @ c
BATH TUB
SO. FT. @ c
WATER HEATER
MAX. HEATER OUTPUT, B.T.U.
SO. FT. RESID @ 1 Va c
SEWAGE DISPOSAL
SO.FT.GAR @ ?/ac
HOUSE SEWEF
GAS PIPING
PERMIT FEE
PERMIT FEE
PERMIT FEE
DBL
TOTAL FEES
MICRO FEE
MECH.FEE PL.CK.FEE
CONST. FEE ELECT. FEE
SMI FEE PLUMB. FEE
STRUCTURE / PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
SETBACK
GROUND PLUMBING
UNDERGROUND
A.C. UNIT
COLL. AREA
SLAB GRADE 2
ROUGH PLUMB.
BONDING
HEATING (ROUGH)
STORAGE TANK
FORMS
SEWER OR SEPTIC TANK
ROUGH WIRING
DUCT WORK
ROCK STORAGE
FOUND. REINF
GAS (ROUGH)
METER LOOP
HEATING (FINAL)
OTHER APPJEOUIP.
REINF. STEEL
GAS (FINAL)
TEMP. POLE
GROUT
WATER HEATER'
SERVICE
FINAL INSP.
BOND BEAM J?
v
WATER SYSTEM
GRADING
cu. yd.
$ plus x$
=$
LUMBER GR.
FINAL INSP,
FRAMING
FINAL INSP.
ROOFING
REMARKS:
VENTILATION
FIRE ZONE ROOFING
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL r
LATHING
MESH
INSULATIONISOUND
FINISH GRADING
FINAL INSPECTION
CERT. OCC.
FENCE FINAL
INSPECTOR'S SIGNATURESJINITIALS
GARDEN WALL FINAL 7d