Loading...
BPAT2015-00017 #'95 CA, -LE TAMPICO U �NtiINCl/ _J LA QWNTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BPAT2015-0001 Property Address: 53120 AVENIDA CARRANZA APN: 774051005 Application Description: (1) 372 SQ FT DURALUM PATIO COVER Property Zoning: Application Valuation: $4,000.00 Applicant: VALLEY PATIOS 37897 CHESTERFIELD ST INDIO, CA 92203 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C51, C-8 License No.: 937811 r— Date: ( L Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the.work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: KAREN HOGAN 53120 AVENIDA CARRANZA LA QUINTA, CA 92253 Contractor: VALLEY PATIOS 37897 CHESTERFIELD ST INDIO, CA 92203 (760)534-4634 LIC. No.: 937811 Date: 1/12/2015 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the Work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: AppIicy't, WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned ropert for inspection purposes. Date: L Signature (Applicant or Agents e r.. c z L L l� m � D N p O CJI WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the Work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: AppIicy't, WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned ropert for inspection purposes. Date: L Signature (Applicant or Agents e r.. 'x.. at { L2 '..h zF Fz �, .. . L{ $ .tb2 x +ACCOUNTsfi ea,: F DESCRIPTION �f G �< PAID DATE QTY. AMOUNT ,rye Y>PA'ID �� E`arl.: BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 s>z_g..--� .'. yt�Crtsa�� � .,: �-h,?�V,. KIT, " h lin t' ` METHOD 3 {� ��9 RECEIPT # CHECK # CLTD.BY � ��+'MPAIDyBY > A �,x n�4, !s xFx'l.. pc':V.�61 CEI T'il. viY .lw�€.n��'i" Total Paid forBUILDINGgSTANDARDS ADMINISTRATION BSA $1.00 $0.00 .vTiY.b4.9i3yS F'ri-Y r- f i DESCRIPTIONF T::.3ix f: .:xH.��e�Y.....',, " MOUNT ,�.?t ',,k RK t ii. n.�...<x., QTY AMOUNT t PAID A a_ PAID;DATE PATIO COVER, STD, OPEN ' 101-0000-42404 0 $97.17 $0.00 'c BYE CHECKr#r_ �CGTD�BfYes .., 7PAID ... .:E 1.. .cMMEfHODY t x.RECEIPT`#a .. _...... �., � e. ��Q ' MOUNT POACCQUNTi'. AID DATE Z11'r%@ Yifl PATIO COVER, STD, OPEN PC 101-0000-42600 0 $95.72 $0.00 ', L' rt PAID BYEMETHOD r7, s CHECK #sr CLT:D BYt ,�< N.uv..,,:�wZ�Fs., :s".-.;'s+.:a_:,sz.: `sa%�;b:-:,�•a.�;3,- �C �:rn-k e_?s__a a.: _..ri; -.;' zRECEIPTS# Total Paid for PATIO COVER / COVERED PORCH / LATTICE $192.89 $0.00 ,i.xre � � x*' .+x F ..»�Vi. � - �• .i. S 'i! � 'i {`� , g 7t': � QTYa �E+f ia\YV=- � ✓. k S' �ry PAID�r�} � 'PAID:DATE ,;DESCRIPTION , �+ i..N....k°Z>°.6FA..3�p•1x ,_^Si. f:ACCOUNTS fty �AIIAOUNT �.': SMI - RESIDENTIAL 101-0000-20308 0 $0.52 $0.00 �'r _. aF t.:3' a i- x'S : fia.^.W ', a ,,. s v t 6' BYE ;`".'q'"Rjt`. V,..�,.,. # ; ztN ayY ; i.: S #- METHO#Da„4 3i "% :.:s ue?~aC.aES. +¢' T$Y .�" RECEIPTCHECK 9q e� ;.fin #I , CLTD BY > s PAID y �, c..? .S a:a ,' .+tv+"'.�,Lim,,,avx.s,,....':..mii`a..'`t'�d'..vs>.,.?. a.�n�`i''T` •,ua'si-S: s , d" -.a aa.,n. mac. ,a r. Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $0.52' $0.00 Description: (1) 372 SQ FT DURALUM PATIO COVER DD •,+ Type: PATIO COVER Subtype: Status: UNDER REVIEW Applied: 1/12/2015 SKH Approved: Parcel No: 774051005 Site Address: 53120 AVENIDA CARRANZA LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 220 Lot: 20 Issued: UNIT 21 NAME CONDITIONS CONTACTS ADDRESSI CITY Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $4,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: PATIO COVER - (1) 372 SQ FT PATIO COVER [ALUMAWOOD ENGINEERING]. 2013 CALIFORNIA BUILDING CODES. Printed: Monday, January 12, 2015 11:20:32 AM 1 of 2 Ll L1 MYSTEIvIS DD •,+ CHRONOLOGY NAME TYPE' NAME CONDITIONS CONTACTS ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT VALLEY PATIOS 37897 CHESTERFIELD ST INDIO CA 92203 CONTRACTOR VALLEY PATIOS 37897 CHESTERFIELD ST INDIO CA 92203 OWNER KAREN HOGAN 53120 AVENIDA CARRANZA LA QUINTA CA 92253 Printed: Monday, January 12, 2015 11:20:32 AM 1 of 2 Ll L1 MYSTEIvIS BOND INFORMATION Printed: Monday, January 12, 2015 11:20:32 AM 2 of 2 P SYSTEMS CLTD DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD -PAID BY BY PATIO COVER, STD, 101-0000-42404 0 $97.17 $0.00 OPEN PATIO COVER, STD, 101-0000-42600 0 $95.72 $0.00 OPEN PC Total Paid for PATIO COVER / COVERED PORCH / LATTICE $192.89 $0.00 SMI -RESIDENTIAL 1 101-0000-20308 1 0 $0.52 $0.00 Total Paid forSTRONG MOTION INSTRUMENTATION SMk $0.52 $0.00 TOTALS:00 BOND INFORMATION Printed: Monday, January 12, 2015 11:20:32 AM 2 of 2 P SYSTEMS Bin # 4 Permit # ProjectAddress: S3SZ� 3 - Qty of LA Q uin to . Building 8t: Safety Division P.O. Box 1504, 78-495 Calle Tampico . La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet �(radl:L—q Owner's Name: '40 0,t1 A. P. Number: Address: �7) j 'Z:(� Av-e . C.x«t /\ Legal Description: City, ST, Zip: l -,;z Q cIt ,� , 9'Z2,j ? • Contractor: U-. 1 Telephone: ��}''._:iii :�����^:; ' Address: �j 7 g C1 5.� , J Project.Description: l v a �/e�O Gt o 6v of City, ST, Zip: • (rvd [ 0 c4 ct 7-2-o 3 37 `Z S-�F Telephone: 5.3 V 1 1, ! V � A?`«?��<<�?`��<`>«<`•`-»''•>: -- .. State Lic. 4: 37 City Lic. #.. Arch., Engr., Designer: Address: City., ST, Zip: Telephone:Construction n:z:<:•<.€<.; s<:>:.ss>z<::i^a:>::»;<.<.:>:<: :.<•;. ,:;:;,::<; :•>::;•;:::;;< Type: Occupancy: State Lic. #: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: Sq. Ft.: % #Stories: -M Units: Telephone # of Contact Person: 53 Ll q b 3 Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE it Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets PIan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Cala. Called Contact Person Plan Check Balance. Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mcchanical . Grading plan 2" Review, ready for corrcctions/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. Ii.O.A. Approval Plans resubmitted Grading IN I10USE:- 3" Rcvicw, ready for corrcctionsAssue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fccs Total Permit Fees. r• ' v', .' • 0!�sAS I, '• CAP.4PBEr -.O �L z Exp: 12 ) T . m •• CIVIL OC. �No .184SA. PATIO COVER SYSTEM AS MFG. BY: DURALUM PRODU SIGN OF ATTACHED AND FREESTANDING COVERS SHOWN IN THIS REPORT COMPLY WITH THE ERNATIONAL BUILDING AND RESIDENTIAL CODES, 2013 CALIFORNIA BUILDING AND RESIDENTIAL ASCE/SEI 7 -10 -MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES AND THE 2010 JM MANUAL -ADM 1-10. COLUMNS BEARING ON CONCRETE SLAB IS IN.ACCORDANCE.WITH 2012 IRC 3 CRC SECTION AH105.2 FOR 10 psf RESIDENTIAL CONSTRUCTION AND AC_1318-11`90R 20,25 AND 30 L A DENTIAND COMMERCIAL: IO CONSTRUCTN. 2- ALL KEYS PERTAINING TO EACH INSTALLATION (TYPE OF ROOF PANEL, HEADER SPAN, COLUMN SIZE, ETC.) SHALL BE CIRCLED AND CLEARLY IDENTIFIED. 3. EACH INSTALLATION SHALL BEAR AN IDENTIFYING TAG INDICATING THE NAME AND ADDRESS OF THE MANUFACTURER DESIGN LOADS AND ENCLOSABILITY. 4. THE DRAWINGS AND SPECIFICATIONS SHOWN REPRESENT THE FINISHED STRUCTURE, UNLESS OTHERWISE NOTED, AND DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. 5. THE APPROVED SET OF DRAWINGS AND SPECIFICATIONS SHALL BE KEPT AT THE JOB SITE AND SHALL BE AVA9ABLE TO THE AUTHORIZED REPRESENTATIVES OF THE BUILDING AND SAFETY DEPARTMENT. THERE SHALL BE NO DEVIATION FROM THE APPROVED PLANS AND SPECIFICATIONS WITHOUT AN APPROVED CHANGE ORDER 6. FREESTANDING COVERS SHALL NOT BE ENCLOSED WITH ANY TYPE OF SOLID OR MESH MATERIAL 7. ALL NEW CONCRETE FOOTINGS SHALL BEAR ON FIRM, NATURAL, UNDISTURBED SOIL OR CERTIFIED FILL 8. ATTACHED COVERS MAY BE SECURED TO AN EXISTING CONCRETE SLAB PROVIDED THE SLAB IS AT LEAST 3 12 INCHES THICK AND IS LOCATED IN AREAS WITH A FROST DEPTH EQUAL TO ZERO. 9. A MAXIMUM COLUMN LOAD OF 750 POUNDS IS PERMITTED FOR ATTACHED COVER COLUMNS BEARING ON EXISTING OR NEW CONRETE SLABS. 10.20 POUNDS PER SQUARE FOOT L.L. AND GREATER MAY BE COMMERCIAL APPLICATIONS AND RESIDENTIAL CARPORTS. 11. DESIGN LOADS COMBINATIONS ARE IN ACCORDANCE WITH IBC AND CBC SECTION 1605.3.1. DESIGN CONSIDERATIONS: 11. MINONUM ROOF SLOPE FOR SOLID ROOF PANELS: 1/4 INCH PER FOOT. 12. MINIMUM COVER PROJECTION IS 10'. 13. MINIMUM SIZE OF EXISTING ROOF OVERHANG IS 50 SQUARE FEET, WHERE COVER IS ATTACHED TO THE EXISTING OVERHANG. 14. COVERS ARE DESIGNATED'RIDGED BUILDINGS' AS DEFINED IN ASCE/SEI 7. 15. COVERS SHALL NOT BE INSTALLED IN AREAS NEAR HILLS, RIDGES AND ESCARPMENTS AS DEFINED IN ASCEfSEI T. 16. THE FREESTANDING AND ATTACHED COVERS NOTED HEREIN ARE DESIGNED AS "OPEN STRUCTURES' IN ACCORDANCE WITH ASCE/SEI 7. 17. THE RATIO (H/P), COVER MEAN ROOF HEIGHT (H, FT.) DIVIDED BY THE COVER PROJECTION OR WIDTH (P, FT), SHALL NOT EXCEED ONE (1). 18. THE RATIO (L(P), COVER LENGTH (L, FT.) DIVIDED BY THE COVER PROJECTION OR WIDTH (P, FT), SHALL NOT BE LESS THAN ONE (1). MATERIAL SPECIFICATIONS: 19. BEAMS SHALL BE SPLICED OVER EACH INTERIOR COLUMN SUPPORT. 20. ALTERNATE ALUMINUM ALLOYS MAY BE SUBSTITUTED FOR THOSE SHOWN, PROVIDED THEY ARE REGISTERED WITH THE ALUMINUM ASSOCIATION AND HAVE EQUAL OR GREATER YEILD AND ULTIMATE STRENGTHS. 21. CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2.500 POUNDS PER SQUARE INCH. 22. DESIGN VERTICAL SOIL BEARING PRESSURE IS 500 POUNDS PER SQUARE FOOT. DESIGN LATERAL SOIL BEARING PRESSURE IS 200 POUNDS PER SQUARE FOOT PER FOOT OF FOOTING DEPTH. (EQUALS 100 PSF/FT x 2 PER TABLE 18062 AND SECTION 1806.3.4. 23. EMBEDDED STEEL MEMBERS SHALL BE HOT -DIPPED GALVANIZED, AND CONFORM TO A500 GRADE B. ROLL -FORMED STEEL MEMBERS SHALL CONFORM TO A653 SS GRADE 50 G60. 24. FASTERNERS: ALUMINUM BOLTS SHALL BE 2024-T4: STEEL BOLTS SHALL BE ASTM A-307. ALL BOLTS SHALL HAVE STANDARD -CUT PLATED WASHERS. WOOD AND LAG SCREWS ARE REQUIRED TO BE INSTALLED IN ACCORDANCE WITH THE NATIONAL DESIGN SPECIFICATION. 25. THE POST -INSTALLED ANCHORS CITED IN THESE CONSTRUCTION DOCUMENTS SHALL BE SIMPSON STRONG TIE. 26. ALL SCREWS ARE SELF DRILLING (SDS) OR SHEET METAL SCREWS (SMS) IN CONFORMANCE WITH ICC -ES ESR 1976 OR APPROVED EQUAL 27. THE TABULATED MAXIMUM COLUMN SPACING WHEN BEARING ON A CONCRETE SLAB IS LIMITED TO USE WITH RESIDENTIAL ATTACHED PATIO COVERS ONLY (10 AND 20 PSF 28. SOLID AND LATTICE ALUMINUM COVERS ARE CLASS A ROOF ASSEMBLY IN ACCORDANCE WITH SECTION 15052, EXCEPTION 2. WIND SPEED CONVERSION TABLE: THE WIND SPEEDS SHOWN IN THIS REPORT ARE BASED ON THE CBC/IBC. FOR USE WITH THE CRC/IRC, DIVIDE THE REQUIRED__ CRCARC WIND SPEED iii 0.6 EXAMPLE: CRC/IRC WIND SPEED IS 85 MPH. THE COVER CONSTRUCTION SHALL BE BASED ON 85 MPH =110 MPH. 0.6 ikGMA.S4ftAY WHERE SNOW LOADS OCCUR, IT IS THE REPONSIBILITY OF THE Ck.�9PE� '- CONTRACTOR FOR THIS POJECT TO VERIFY WITH THE LOCAL AUTHORITY HAVING JURISDICTION WHERE SNOW DRIFTING AND SLIDING, PER ASCE 710, SECTION 7.7 AND 7.8, IS REQUIRED. SEE SHEETS 49 FOR SPAN REDUCTION FACTORS. ThinkPadM)uratumUAPMO 019515-21-14 Submlt1ar&21-14 A 4.dwg, 8 /25 /20 1 4 2:1327 PM, CutePDF Wrfter, DESIGN REQUIREMENTS: INC. RESIDENTIAL APPLICATIONS - CRC AND IRC APPENDIX H. CBC AND IBC CHAPTER 16, CBC & IBC APPENDIXCHAPI ROOF LIVE AND SNOW LOADS: 10, 20, 25, 30, 40 & 50 psf. (SNOW LOADS AT GROUND LEVEL 25, 30, 40 & 50 psf) COMMERCIAL APPLICATIONS - CBC AND IBC CHAPTER 16. ROOF LIVE AND SNOW LOADS: 20, 25, 30, 40 & 50 psf. (SNOW LOADS AT GROUND LEVEL 25, 30, 40 & 50 psf) ADDITIONAL DESIGN REQUIREMENTS: I. TABULATED SPANS FOR SNOW LOADS HAVE BEEN ADJUSTED FOR ROOF APPLICATIONS. 2. BASIC WIND SPEEDS: 110, 120.130 MPH, EXPOSURES B AND C. 3. OCCUPANCY CLASSIFICATION AND RISK CATEGORY: 11, 11. 4. SEISMIC BASE SHEAR: 17 POUNDS PER LINEAR FOOT PER WIDTH OF COVER. 5. SEISMIC DESIGN PARAMETERS: SITE CLASS: D SEISMIC DESIGN CATEGORY: D MAPPED SPECTRAL RESPONSE COEFFICIENTS: Ss= 1.50, S, = 0.6, S �= 1.0, S.= 0.50 RESPONSE MODIFICATION FACTOR 8125 6. DESIGN ASSUMPTIONS: A BUILDING HEIGHT OF MAIN STRUCTURE (MEAN ROOF HEIGHT): 20' B. LEAST BUILDING WIDTH OF MAIN STRUCURE: 30' C. MINIMUM COVER SIZE ATTACHED TO MAIN STRUCTURE OR FREESTANDING: 10'X 10' A NOTE TO THE LOCAL AUTHORITY HAVING JURISDICTION: EACH PROJECT SUBMITTED TO THE LOCAL AUTHORITY HAVING JURISDICTION MAY INCLUDE ONLY THE PERTINENT SITE-SPECIFIC STRUCTURAL COMPONENTS LOCATED WITHIN THIS WPMO-LISTED EVALUATION REPORT. AT A MINIMUM, SUBMISSION FOR A BUILDING PERMIT MUST INCLUDE THE FOLLOWING INFORMATION FROM THIS EVALUATION REPORT: A. TITLE SHEET AND GENERAL NOTES. B. STRUCTURAL CONFIGURATION (Le.. SOLID OR LATTICE ROOF, FREESTANDING OR ATTACHED). C. BASED ON THE REQUIRED DESIGN LOADS, SITE-SPECIFIC RAFTER AND/OR PANEL SPAN TABLES. D. TYPE OF HEADER, POST TYPE & QUANTITY, FOOTING SIZE (WHERE REQUIRED) BASED ON THE SITE-SPECIFIC DESIGN LOADS. E. APPROPRIATE STRUCTURAL DETAILS. F. OTHER DOCUMENTATION THAT MAY BE REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. SHEETINDEX: SHEET # SHEET TITLE / DESCRIPTION p'lds ]Cl (A jL3jVS -Q Jrv_ 1a_ine, lo WIND SPEED CONVERSION TABLE: CBC / IBC WIND SPEED EQUIVALENT CRC / IRC WIND SPEED 110 MPH 85 MPH 120 MPH 93 MPH 130 MPH 101 MPH SEE CONVERSION METHOD, THIS PAGE, FOR APPLICATION AND USE. SITE DESIGN PARAMETERS: SITE ADDRESS: WIND SPEED & EXPOSURE: ROOF / SNOW LOAD: T-1 ........... TITLE SHEET, DESIGN LOADS, GENERAL NOTES 1 ............SOLID PANEL STRUCTURES 2 ............OPEN LATTICE STRUCTURES 3-4 .........PANEL SPANS TRI -V, W -PANEL & FLAT PAN 5 ............MINIMUM FASTENERS 6 ............RAFTER SPANS FOR OPEN LATTICE COMMERCIAL & PATIOS 7 ............HEADER BEAM TYPES, COLUMN / POST TYPES 8 ............EXISTING EAVE CONNECTION DETAILS 9 ............HANGER CHANNELS AND MOUNTING BRACKETS 10 ..........COLUMN / POST SURFACE MOUNT AND FOOTING EMBEDMENT DETAILS 11 ...........LATERAL FORCE RESISTING SYSTEM / MIN. NUMBER OF REQ. COLUMNS 12 ...........BEAM TO POST & LATTICE TUBE TO RAFTER CONNECTION DETAILS 13 ...........HOW TO DETERMINE TRIBUTARY WIDTH & FAN BEAM DETAILS 15-17 ......SOLID COVERS ATTACHED & FREESTANDING BEAM SPANS, 10 PSF L.L, 110-130 MPH 18-20 ......SOLID COVERS ATTACHED & FREESTANDING BEAM SPANS, 20 PSF L.L, 110-130 MPH 21-23 ......SOLID COVERS ATTACHED & FREESTANDING BEAM SPANS, 25 PSF S.L, 110-130 MPH 24-27 ......SOLID COVERS ATTACHED.& FREESTANDING BEAM SPANS, 30 PSF Sl, 110 -130 -MPH 28-30 ......SOLID COVERS ATTACHED & FREESTANDING BEAM SPANS, 40 PSF S.L, 110-130 MPH 31-33 ......SOLID COVERS ATTACHED & FREESTANDING BEAM SPANS, 50 PSF S.L, 110-130 MPH 34-36 ......LATTICE COVERS ATTACHED & FREESTANDING BEAM SPANS, 10 PSF L.L, 110-130 MPH 37-38 ......LATTICE COVERS ATTACHED & FREESTANDING BEAM SPANS, 20 PSF L.L, 110-130 MPH 39-40 ......LATTICE COVERS ATTACHED & FREESTANDING BEAM SPANS, 25 PSF S.L, 110-130 MPH 41-42 ......LATTICE COVERS ATTACHED & FREESTANDING BEAM SPANS, 30 PSF S.L, 110-130 MPH 43-44 ......LATTICE COVERS ATTACHED & FREESTANDING BEAM SPANS, 40 PSF S.L, 110-130 MPH 45-46 ......LATTICE COVERS ATTACHED & FREESTANDING BEAM SPANS, 50 PSF S.L, 110-130 MPH 47 ...........INSULATED ROOF PANEL ATTACHMENT DETAILS 48 ...........SNOW DRIFT DESIGN 49 ...........SPAN REDUCTION FACTOR TABLES W w z 0- z = o w n, W�< F V tq < caz J � z waM a w � K U Q 0 0 U Q U 0�z U K IxZ 0 U I n E mg, LL 0leJ ; Q?„,m 2.5p; Y�tano U)Oui > CL UDa� OQ�� F m,o m aomml w Z u sw.. >. CD .5;28 3 ,ii Lu L H �otocc Na.C37948 EXP: 03:'31/% x 0' HO,',MAS 1. CAMPBELL'•� �2 4 1 :m U ; fid, •-, EKp: : c CIVIL d ROOF No •j 8,;��4 THOMAS IRAY ThinkPadU)uralumVAPMO 0195%5-21-14 SubmtnaKS-21-14 A 5.dwg, 8/l7/2D141135:45 AM. CutePDF WrtMr, SOLID PANEL STRUCTURES ROOF ROOF - , ROOF PANEL SEE TABLES ATTACHMENT SEE DETAIL A. B & C. OVERHANG, �E/y OR WOOD, OR ATTACHMENT SEE DETAIL A. B & C. ROOF PANEL SEE TABLES �ENGT OVERHANG,cc OR WOOD, OR Z W z SHEET 4 FOR ROOF SHEETS GTH CONCRETE MID S OF S TRUC SHEETS SHEET 4 FOR ROOF MID S H OF ST CONCRETE i z S PAN L ATTACHMENT TOSUPPORTING Hq�t WALL SEE PAN L ATTACHMENT TO hgtt RUC WALL SEE W N THE RO E HSE ES SHEETS 8 0.25" SLOPE PER FT. TNF RO �SE IFS SHEETS & WALL l " WALL SU PORTINANGER T m HANGER BEAM. & BEAM.MIN. cc O. SPAN O, "O.H." NOT TO EXCEED 25°% "O.H.' NOT TO EXCEED 25%w € 0 OF ROOF PANEL OF ROOF PANEL m 2 ALLOWABLE SPAN ALLOWABLE SPAN f 't Z SEE DETAIL 11, SHEET 12 B SEE DETAIL 11, SHEET 12 B EgMSp U 5 FOR MANDATORY SPLICE. POST BEAM -SEE TABLES FOR MANDATORY SPLICE. POSTS '�/ BEAM -SEE TABLES o a z f- 0 4a NO BEAM SPLICE AT POSTS. Spm/ SEE X NO BEAM SPLICE AT EXTERIOR POSTS. SFE TgeL�S NG FOR POST SPACING ilu EXTERIOR T,gBL�NG S � POSTS, SIZE VARIES O.N. Np 25% TO POSTS, SIZE VARIES O•h NOT m 0 U SEE SHT. 11 FOR MINIMUM OF EkC iv BEgMA O SEE SHT. 11 FOR MINIMUM pXCEED 2 iv NUMBER OF REQUIRED COLUMNS OwABCE NUMBER OF REQUIRED COLUMNS q�� �M S/'Aly oW geCE SPA _ a a e� 0 ooi 3 1/2" SLAB ATTACHMENT MAY BE USED NOTE: NO SPLICE AT IOR POSTS 3 1!2" SLAB ATTACHMENT MAY BE USED 0 0 � o WHERE PERMITTED. WHERE PERMITTED. SEE TABLES SEE TABLES �o NOTE: EACH COMPONENT IS INTER- NOTE: EACH COMPONENT IS INTER- e Z o N FOOTING WHERE REQUIRED CHANGEABLE WITH ANY OTHER FOOTING WHERE REQUIRED CHANGEABLE WITH ANY OTHER Q SEE TABLES COMPONTENT UNLESS OTHERWISE SHOWN. SEE TABLES COMPONTENT UNLESS OTHERWISE SHOWN. j 0 TYPE "A" ATTACHED SINGLE SPAN W/ CANTILEVER OPTION TYPE "B" ATTACHED MULTISPAN W/ CANTILEVER OPTION J WW w Z ¢ a� • p U J 0 N ROOF PANEL SEE TABLES LEj SHEET 4 FOR ROOF PANEL yGTH OF ST S7 -RUC ROOF PANEL SEE TABLES LENGTH OF ATTACHMENT TO SHEET 4 FOR ROOF PANEL MIN. 0.25' SLOPE STRUC SUPPORTING BEAM. O.H VqR/ES ATTACHMENT TO PER FT O.H n/RE VARIES SUPPORTING BEAM. } r O.H. SPAN O.H. SPA LL "O.H." NOT TO EXCEED 25°% "O.H." NOT TO EXCEED 25% SPA a z OF ROOF PANEL OF ROOF PANEL m ALLOWABLE SPAN ALLOWABLE SPAN - 0 0a SEE DETAIL 11, SHEET 12 ✓ FOR MANDATORY SPLICE. B FgA1 SEE DETAIL 11, SHEET 12 B �� `� o NO BEAM SPLICE AT Sp �'OSTSp'�/ BEAM - SEE TABLES FOR MANDATORY SPLICE. SPit NO BEAM SPLICE AT POST Spm/ BEAM - SEE TABLES a.w - EXTERIOR POSTS. SEE TgB�ES NG FOR POST SPACING EXTERIOR POSTS. SFE TABLE llyG FOR POST SPACING = o 5 z r POSTS, SIZE VARIES • —4O No 7- � S POSTS, SIZE VARIES Oh NOT T�II MAY E USED • ops N AM ALO 48LFSp ' AN MAY E USED OF ALO A8LESp - AN ul TO CONSTRAIN TO CONSTRAIN IIIIff i FOOTING, SEE __ „__. _ . _ _ FOOTING, SEE. 7 _ _+ 'a'i.� z> TABLES TABLES AD W = FOOTINGS FOOTINGS SEE TABLES _ NOTE: EACH COMPONENT IS INTER- SEE TABLES NOTE: EACH COMPONENT IS INTER- CHANGEABLE WITH ANY OTHER CHANGEABLE WITH ANY OTHER o o, COMPONTENT UNLESS OTHERWISE" SHOWN. COMPONTENT UNLESS OTHERWISE SHOWN. LL O TYPE "C" FREESTANDING W/ CANTILEVER OPTION TYPE "D" FREESTANDING MULTISPAN W/ CANTILEVER OPTION W W ThinkPadU)uralumVAPMO 0195%5-21-14 SubmtnaKS-21-14 A 5.dwg, 8/l7/2D141135:45 AM. CutePDF WrtMr, ~ W. 037948 EXP. 031391 i ........ "T NO ,AS I. CAMPBELL = Q Exp.I2 I+ ; z .m CIVIL D Ho t84 THOMAS IRAY CAA5MELL OPEN LATTICE STRUCTURES 0 'WALL LEDGER OR w RAFTER SEE TABLES 1 �� �\� "•+ oZZ \_ ; m y �!SnNG ROOF OVERHANG, V ? A /HGB` WALL LEDGER OR 8tSEE 'Vo N SH ET AIL A.8 8 C Z W o n ROOF OVERHANG, p' W a A MAX. O.H. O.H. SEE DETAIL AB 8 C, r 25% OF RAFTER 6 SHEETS. (ALLOWABLE RAFTER, SEE TABLES CJ m �Sgo.'p SPAN �(pOceMAX O.H. °e 25% OF RAFTER O.H ¢ a a So 2S 4rq l ALLOWABLE Z Z �V fpr 0 SPAN w n posy' m m c� Sp G gw� Z = MANDI TORY BEAM SPICE -SEE i DETAIL 11, SHEET 12 �� OG - NO BEAM SPLICE AT EXTERIOR POSTS �3� 4 t� LENGTH OF STRUCTURE VARIES O -RG w MANDATORY BEAM SPICE -SEE x c0i x DETAIL 11, SHEET 12 Cr, OG' -POST WITH SIDE PLATES NO BEAM SPLICE AT B SEE SHT. 11 FOR MINIMUM EXTERIOR POSTS �3 0 NUMBER OF REOUI R S Spq 4y� COLUMNS LENGTH OF STRUCTURE VARIES j O' n ILm 3 12' SLAB AlTACHMENT 6 IVIIWII o MAY BE USED WHERE pbSSp POST WITH SIDE PLA OSS Sp PERMITTED. S rSp vy� SEE SHT. 11 FOR MINIMUM NOTE: EACH COMPONENT IS INTER `SFF SpggB(LZ SEE TABLES T ciyG NUMBER OF REQUIRED o o } l ry , (F COLUMNS CHANGEABLE WITH ANY OTHER ...FSV' ••.. �- � S 6 0'o i COMPONTENT UNLESS OTHERWISE SHOWN. FOOTING WHERE REQUIRED, NOTE: EACH COMPONENT IS INTER- p0 asp 3 112' SLAB ATTACHMENT o Z ';s SEE TABLES CHANGEABLEWITH ANY OTHER SSp M. a NOTE: THIS OPEN LATTICE -TYPE STRUCTURE FF qC/ i MAY BE USED WHERE o.J MAY'NOT BE COVERED. , COMPONTENT UNLESS OTHERWISE SHOWN. 9aG SEE PERMITTED. TTE. z =- l 1. NOTE: THIS OPEN LATTICE -TYPE STRUCTURE IJ ABLES MAY NOT BE COVERED. \ FOOTING WHERE REQUIRED, f SEE TABLES rr TYPE "E" ATTACHED-SINGLE:_SP_AN-LATTICE STRUCTURE TYPE "F" ATTACHED MULTISPAN LATTICE STRUCTURE W U W J Lu d ILP_ 0 RAFTER. SEE TABLE FOR SIZE AND SPACING MAX. O.H. RAFTER, SEE TABLE $ 25% OF RAFTER O.H. FOR SIZE m E 2S% M TOWABLE AND SPACING N m 2 Opp' C O SPAN MAX O.H. m m pSt 1'Fq,. O.H 25% OF RAFTER LL Spgc/7q^G 2Sp y . ALLOWABLE o _ ,yG �pF O SPAN N Z io a_Wm Ac/^G wow Wx F � _ eJaa� ,n c� iLu U�a� x O��Q LENGTH OF STRUCTURE VARIES Rte (C� OG' C > m m comm MANDATORY BEAM SPICE -SEE----/9'p O DETAIL 11, SHEET 12 R rW NO BEAM SPLICE AT POST CROSSSECTI LENGTH OF STRUCTURE VARIES 8 EXTERIOR POSTSqDS SEE POST DETAI a� SF rS MANDATORY BEAM SPICE - SEE o FrgB �/ - - •DETAIL 11: SHEET 12' POST CR SS-SECTION,......'.v- ' MAYBSLAB E USED NO BEAM SPLICE AT 'T' J, SEE POST DETAIL, m C us.. NOTE: EACH COMPONENT IS INTER- /jjS I TO CONSTRAIN EXTERIOR POSTS Ftgc/,� 3 y CHANGEABLE WITH ANY OTHER SFF t� TABLESFOOTIN SEE S 3 12' SLAB q¢ COMPONTENT UNLESS OTHERWISE SHOWN.t'Ie q�/NG MAY BE USED o o �s NOTE: EACH COMPONENT IS INTER- TO CONSTRAIN FOOTING, SEE NOTE: THIS OPEN LATTICE -TYPE STRUCTURE CHANGEABLE WITH ANY OTHER S� Sp MAY NOT BE COVERED. FOOTING SEE TABLES COMPONTENT UNLESS OTHERWISE SHOWNt 9CjHG j J TABLES n • . v NOTE: THIS OPEN LATTICE -TYPE STRUCTURE FOOTING SEE TABLES� u. . MAY NOT BE COVERED. C O W N O 1j TYPE "G" FREESTANDING `SINGLE SPAN LATTICE STRUCTURE TYPE "H" FREESTANDING MULTISPAN LATTICE STRUCTURE suj ThinkPad\Duralum\IAPMO 0195\5-21-14 SubmftmhS21-14 A SAA, W7201411 772 AM, CutePDF Writer, No. 037948 EXP. 03.1311 %, H0,:4AS I. CAIMPSELL , o Exp: CIVIL THOMAS IRAY CAMPSELL 24' TRI -'V' PAN SOLID PANELS SPANS FOR COMMERCIAL & PATIOS 110/120/130 MPH EXP. B & C ALUM. ALLOY 3004-H36 OR EQUAL TABLE 1 - MULTI -SPAN REDUCTION FACTORS FOR ROOF PANELS ROOF PANEL TYPE 10 ROOF LIVE/SNOW LOAD, psf 20 25 30 40 50 24' TRI -N- PAN - 0.88 0.83 0.75 0.80 24-.2}4-x0.018' 0.85 0.80 0.65 0.65 - - 24NZJ'x0.024• 0.90 PANEL -1' 110 MPH SPAN 120 MPH SPANrEXP.B LUSL H SPAN LUSL (IN.) EXP.B EXP.0 EXP.B EXP.0EXP.0 PANEL -r 13'-9- 13' 9' 1a-3" 103' 1a-3• 1 a-3- OF 1 a-3•.018 (IN.) LUSL (IN.) w EXP.B EXP.0 EXP.B EXP.0 EXP.B EXP.0 EXP.B EXP.0 EXP.B EXP.0 EXP.B EXP.0 1 z-0- 11'-1' 11'-2• 10'-7 10'-T 8-1- r-5'1231 15-3- 1573' 15'3• 123• 1231 1737 o 1Z3• 10 .024 13-r 12-T 10�' 9'-9" 9'-9" 9'-r 9'-3' 8'-T lr7' 1T-7' 14'-3' 14'3• 14'3' 14'3• 14'3' 14'3• .032 t r-0• 1 z-0- 1 rte• 11 t x-9- 1 S$' 14. 9- 14'-9- 17$- 1 r -r 1z -r 1 r -r 1 r3• lo'$• 19'-T 19'-T 8•-4" 8•$• 8'4' 8'4' 8•-4' 8'-4' 018 024 1 T -r 16'$' 16'-9' T-9" T -S T-5' T -r T-2' 6--10- 11'3• 11'3• 101-11 1a-1• 1x-17 1a-1• 1a-1• 10'-1• 20 .024 14'-r 13'x' 13�' 10'-t• 9'-6• 9•$- w 8' 9'-1' 8' 8' 157-7• 17$' 17$' 1 r-6• 1r -r 1r -r 1z -r 1z -r 1z-1• 1z -r 18 0 .032 a a lr-r to -9- 1a -s• 1a 9' 1x31 1o4' 91$" 7-9• 91-9• 14'$' 14'$• T3' T3' T3' T-3' T3' 7'3' .018 13'-1' 13 4' 12 4" 1 Z-0' 13 3' 1z-9" 17-9- T-8' r$• T-4• T-1• T-1• 6'-10' 16'3' 16'3' 8'-9• g'-9' 8=9' 8'-9- 8'-9' 8'-9' 25 .024 19'4• 19'-4' 19'4' 1 S-1' 14'-T 14'-7' 8'-8' 8'-4' 8'-5' 8'-1' 8'-1' T-9' 11•-1• 11'-11 9'$- 9•$' T-8" 9'-8- 9'$• 9-$' .032 14'-70' 14'-10' 14'-1' 9'-10- 9'-3• 9'S• tai' 10'-r 10'-r 9•-r 9'$' 7-r 1r-0• 1r-0• 6.7- 6'-r 6 r 6•-r 6•-r 6'-r .018 00 T-0" 6'-9' 6'-10' 6'-T 13'-7 13'-r 8'3• 8.3' 8.3' 8,3- 8.3' 8'-3' 30 .024 >1Z ozo 9•-1' 13'-1 • 12-T 1 r$' 8'3' 8'-0' 8'-0' T-9' T-9' T-5' 14•-z' 14'-2' 14•-2- 9-1' 9-1' 9'-1' 9•-1' 9-1' 11•-0- .032 11'-4" 13'3" 13'-3' 13'-3• 1 S-0' 14'-4' 14'-r 9'-10' 9' 6' 9'$' 9-1' 9'-r 10'-6• TABLE 1 - MULTI -SPAN REDUCTION FACTORS FOR ROOF PANELS ROOF PANEL TYPE 10 ROOF LIVE/SNOW LOAD, psf 20 25 30 40 50 12-x3Yz-.0.020• - - 0.88 0.83 0.75 0.80 24-.2}4-x0.018' 0.85 0.80 0.65 0.65 - - 24NZJ'x0.024• 0.90 0.88 0.70 0.65 - - 24'x2X•x0.03r 0.90 - 0.88 - - - :j (1) MULTI -SPAN REDUCTION FACTORS ARE ONLY APPLICABLE TO THOSE ROOF PANEL TYPES SHOWN IN TABLE 1 ABOVE. NOTE: PANEL FASTENERS _ ARE SHOWN IN TABLES 1,2 AND 3• SHEET 4 FOOTNOTE: 'SAMPLE' FIGURE INDICATES -a ATTACHED FIGURE INDICATES FREESTANDING Th1nkPad0uralumltAPM0 0195 21-14 Submhg\5-21-14 A 5.dwg, 8272014113936 AM. CutePDF WrOer, ALUM. ALLOY 3004-1-136 OR EQUAL 6'/ 8'x2Y2'FLAT PAN 09R (LS. L�.77- 1 (ALL UNMARKED RADu m.R) 15- B2 2 5' 39* T= (SEE TABLE BELOW) 45' TYP. 1.92 .7 1.92 .757 1.92 wra o0' ALUM. ALLOY 3004-H36 OR EQUAL m:m z R Luz Z z o W n w, W KQ A azo O¢�¢` NtoU Q � � O z us 0 w 0 mw� � ¢ U ca,Z$ 12"x 3 1/2'W PANEL 8"x 2 Y' FLAT PAN PANEL -r 110M SPAN 1 120 MPH SPAN 130 MPH SPAN LUSL (IN.) EXP.B EXP.0 EXP.B EXP.0 EXP.B EXP.0 PANEL -r 13'-9- 13' 9' 13'-9' 13'-9• 13'-s• 13•-9• OF 020 (1) (IN.) LUSL (IN.) w EXP.B EXP.0 EXP.B EXP.0 EXP.B EXP.0 EXP.B EXP.0 EXP.B EXP.0 EXP.B EXP.0 1 z-0- 11'-1' 11'-2• 10'-7 10'-T 9 -11 15-3- 1573' 15'3• 1573• 1 573' 15-3• o .024 020 13-r 12-T 1r$' 11-1(I• 1r-0• 17_1• 10 Ir 7- lr7' 1T-7' 1T -T 1T -r 1T -r 9•-T 032 1 Z-8 t r-0• 1 z-0- 1 rte• 11 t x-9- 1 S$' 14. 9- 14'-9- 14'-0" 14'-l' 13'-3' l w r 19'-T 19'-T 19'-T 19'-T 19'-r 5-10- .040 024 1 T -r 16'$' 16'-9' 15'-9" 16'-0• 151-W 11'3' 11'3• 11'3• 11'3' 11'3• 11'-3' 11'4' 020 (1) 1a 9• 1a-1' 14'-r 13'x' 13�' 10'-t• 9'-6• 9•$- 9'-0' 9'-1' 8' 8' 157-7• 17$' 17$' 1 r-6• 1 r$• 1Z-6' 12$' 18'-0• 024 18•-0 18 0 18'-0• a a lr-r to -9- 1a -s• 10.3• 10'4• s• -1o• 20 14'$' 14'$' 14'$• W-8 - 14'$• 14'$' .032 13'-1' 13 4' 12 4" 1 Z-0' 13 3' 1z-9" 17-9- 17�' 1 r4- 11'-r 15 -1 -1T 16'3- 16'3' 16'3' 16'3' 16'3• 16•-3- .040 19'4' 19'-4' 19'4• 19'-4' 19'4' 1 S-1' 14'-T 14'-7' 13'$• 14'-1 • 13'-r 11•-1- 11•-1• 11'-11 11'-1' 11'_1- 11'_1- 020 (7) oN157-T 14'-70' 14'-10' 14'-1' 9'-10- 9'-3• 9'S• 8'-1-1 a""-0' 1s -101T-0'16•-4 17-0- 1r-0• 1r-0• tr-0• 1z-01 1x-0- .024 00 9'-9• 25 1a-2" 13•-r 13'-7 13'-r 3' -r 13'-r 13•-r 1r -r 032 tr-1- 17-1• 17-1- >1Z ozo 9•-1' 13'-1 • 12-T 1 r$' . 1 Z-2 1 Z-3- 020 to -10• 1a�' 14'-r 14•-z' 14'-2' 14•-2- 14'-r 14'-r 11'4" 040 11'4- 11•-0- 11'4' 11'-4" 13'3" 13'-3' 13'-3• 1 S-0' 14'-4' 14'-r 13'-T 13'$' 13'-0- ' 024 10'-6• 10.6" 10'$• 10'$• 1x-61 10•$- 020(1) --w 20 9'-r 8•-9• 8'-11' 8'-5• 8$' 8'-2 8-11- 20 11'3' 11'3" 17'-3' 11'-3' 17'3' 1a -r .024 13'-0• 13'-0" 13.0' 13'-0" 13'-0' 13'-0- 1 a$' 1 0'-1' 10'-2' 9 -7- 99- 1 S$• 30 1z$' 17$' 1Z$• 1z$• ir$7 17$' .032 17-10• 114 11 6' 11'-0' 11'-0' 10'$" 1z�- tz-r tt•-1o• trs• tri• tt'-r 1z$' 13'4' 13'4' 13'-4' 17-4" 13'x- 13.4" 14' 6' .040 1040 6'$• 1s$• 1s$• 16'-0• 16•$' le-Wz 040 9'-1• 9'-1• 9=1• 9'-1• 9•-1- 020(7) 13'�i• 12-10'1 8'-3' 8'-1• 8'-1' T-10• T$' 1 S -r 14'-10' 1x3- 1x31 tai• F3' tai• 10•-3' 9'9 oza -9 9-s' 10'.41 to -4• 10'-4' 9'-5' 9'-1' 9'-1' i8'-3' B'-10' 8'-T 40 11'x' 11'-4' 17•-4' 1V-4" 11'-4- .032 11'3' 11'-1' 11'-0' to -r 10'$' 10'-3' 1 a$- 7z-2• 1Z,r l Z 2" 17-r i Z 2" 1712* .040 i a 10W 1x-4- .44' 10'-4- 11'-1• 11•-1' 11'-1' 11•-1• 11'-1' 11•-1• 12$• 1 Z 4' 174• 17-1' 77-1 • 11'$' 024 8•-r 8'-2* v 2" 8'-2" 8'-r 8'-r .020(l) 9'-11' 9'-r 9'-r 9'-2- 9'-3' 1Z-0' 11'-0' 11'-T to -10' 11'-0• 6'-9' a; 9'-r 9•-r 9•-r 9•-r S• -r 9'-r 11•-4' .024 1r-4• tr-r 1r -r 1r -r 1r -r 1z -r 17-1- B' 0' T-10- T-10- T$' T$' T$' 5D 10'-r 10'-T 10'-T 10'-T 10'-r to -r .032 11'-10• 11'3 9-r 9-T 9-r s3• 9' 57 8•-1r 14•-1' 13'-71 11'3' 11'3' 71.3• 11.3• 11�101-WIU-4' 1Z-3' .040 1Z-3' 1r-3' 1Z3' 173' 13-1- 13-1' 13-1• 11'-0' 10'-1o• 10'-t0• 10'-r 6'/ 8'x2Y2'FLAT PAN 09R (LS. L�.77- 1 (ALL UNMARKED RADu m.R) 15- B2 2 5' 39* T= (SEE TABLE BELOW) 45' TYP. 1.92 .7 1.92 .757 1.92 wra o0' ALUM. ALLOY 3004-H36 OR EQUAL m:m z R Luz Z z o W n w, W KQ A azo O¢�¢` NtoU Q � � O z us 0 w 0 mw� � ¢ U ca,Z$ 8"x 2 Y' FLAT PAN 6' x 2 Yi FLAT PAN g J o LUSL PANEL -r 110 MPH SPAN 12D MPH SPAN 130 MPH SPAN PANEL -r 110 MPH SPAN 120 MPH SPAN 130 MPH SPAN OF (IN.) LUSL (IN.) w EXP.B EXP.0 EXP.B EXP.0 EXP.B EXP.0 EXP.B EXP.0 EXP.B EXP.0 EXP.B EXP.0 1 Z$• 1 2-061 1 Z-6• 1 Z-0• 12$• 1 Z$• 14'-T 14'-r 14'-r 14'-T 14'-r 14'-r o 020 020 10'-10- 1 a-1 • 10'3- -6-0 9•-T 9'-0• 1 Z-8 t r-0• 1 z-0- 1 rte• 11 t x-9- 13•-r 13'-r 13'-7- 13'-T 5'-10' S-10' 5'-10" S-10 s, 10- 5-10- 024 024 1Z-1' 11'4' 11'-0' 1a 9• 1a-1' 14'-r 13'x' 13�' 1z 8- 179N197-4' 10 10 157-7• 16 r 15-7- 15•-7" g3�'-7'13'-r 15'7' 18'-0• 16-0' 18•-0 18 0 18'-0• a a 032 A32 13'-1' 13 4' 12 4" 1 Z-0' 16 -2' 15'$' 1S -9'1S-0' 15 -1 -1T -r 1r -r 1T -T 1r -r 1T -T 19'4' 19'-4' 19'4• 19'-4' 19'4' 040 oN157-T 14'-70' 14'-10' 14'-1' 14'-r 13' 4' 1T$' 1s -101T-0'16•-4 16•-6' 6-0 H c 00 19 2" 1a-2" 10' 2* 10•-r 10'-2• 10'-2" 1r -r 17-1- tr-1- 17-1• 17-1- 1s4- ozo 9•-1' 8'-9' 8'-9' 8 4• 8'6• T-11' 020 to -10• 1a�' 1x37 9'-9• 9'-10• 9 5• z a� 11'4" 11'4' 11'4- 11•-0- 11'4' 11'-4" 13'3" 13'-3' 13'-3• 13•-3' 13'3- 13'3• Li 024 - 024 --w 20 1a-1• 9$- s-9• 9-3• 9•-5• 8-11- 20 1r -z• 11 1 1r -r 173• 1a -r _ 13'-0• 13'-0" 13.0' 13'-0" 13'-0' 13'-0- 1 S$• 15-6- 16-6" 1 Ski' 15' 1 S$• D32 032 17-10• 114 11 6' 11'-0' 11'-0' 10'$" 14'-r 13'-9' 13-r 13-0- 13•-r 1z$' 14'-6' 14'-06- 14' 6' 1040 6'$• 1s$• 1s$• 16'-0• 16•$' le-Wz 040 13'�i• 12-10'1 r 6' 11-10• 15'-0' 1 S -r 1 S -r 14'-10' 14'-10• 14'3•020 9•9 9'9 -9 9-s' 10'.41 to -4• 10'-4' 10•-4• 10'x• 1174• i8'-3' W14'-6"'$• 020 T-10' 1 a$- 1 a-1 • 10'3• 9.47 9 -9' 9'4'va024 i a 10W 1x-4- .44' 10'-4- 11'-1• 11•-1' 11'-1' 11•-1• 11'-1' 11•-1• 024 9'-11' 9'-r 9'-r 9'-2- 9'-3' 1Z-0' 11'-0' 11'-T to -10' 11'-0• 10'$' a; 1r-4• 1r-4' 174• 11•-4' 1714• 1r-4• tr-r 1r -r 1r -r 1r -r 1z -r 17-1- o3z o3z 11'-10• 11'3 11'3- 10' 9 10'-10- 10'4' 14•-1' 13'-71 1744 13'-1• 13'-2' 1Z -4- 1Z-3' 1r-3' 1Z-3' 1r-3' 1Z3' 173' 13-1- 13-1' 13-1• 13-1• 13'-1• 13•-1• .040 040 13'3- 17-9' 17-9" 12-3 77�" 11'-9' 14'$' 14'-9' 14'-1' 0 E n � 9'3• 9'-3 9-3 93' 9-3• 9'3' 9•-9- 9'-9• 9'-9' 9'-9" 9'-9' 7 T co .020 r-9' T-10• r$' 020 9•-11- 9-r 9 7- 9 2- 9'-4' 8=117 LL v d_ 9'-9" 9'-9• 9'-9' 9'-9' 9•-9" 9•-9• 1(74- 10'-4• 10.4• 10'-4• 1 x47 10'-4• m V .024 .024 Q Z w 9'$' 9'-1' 9'-r 8•-t0• 8•-11• 8' 4' 11•-0' 10' s' 11'-0' 1x-47 10-6' 9--11' 6 G 30 . 101-9" 10-9- 10•-9- 10'-9• 10'-9• 10'-9• 11'4" 11'4" 11'4• 11'-4• 11•-4' 11'-4• 032 11'-1' 10'$' 1 0'-9• >1 0--4 1 ate' 1 a-0- 032 13'-r 1 r$' 13 -0' 17$• 1 r -T 1 r-10 } m o It 11'7• 1 r -r 11'-r 11'-r 1 r7• 1 r -r 173- 173- 173• 1 z3• 123• 1 z3• > a < oxo w n 0 17-r 17-2 12-r 11'$' 11'-9- 113' 14 9• 14'$• 14•-r 14'-r 14•-r 13-r U ? IE n- 8 4' 8'�' 8' 4- 8' 4' 8 �- 8' 4' 9'-0 9'-0• 9'-0• 9•-0' 9'-0' 9'-0' 0 K .020 .020 m a o T$• T$' T$' T-3' T -r 6-11' 9'-1' 8'-10• 8'-10' 8'-T 8-0' g_1• ie 9'-0- 9•-U- 9•-0' 9'-01 9'-0• 7-(r 9'-6' 9'-0• 9'-0' 9'$' 9'-6• W -W 024 024 W 8'$' 8'-3" 8'-3• V-0' 8'-T T -to• 10'-r 9'-10' 9'-10' 9'-r 9'$1 91-7 a�F 0 9-9' 9-9' 9-9" 9'-9' 9-9' 9'-9• 17-1' 1T-9• 12•-9' 1747 1Z -r 1? -1• i .032 � v 10'-r 7-10' 9-10• w -r 9'-r 9'-3• to -3• 10'-1- to -1• 8'-10• _ 9'-10' 8'$• diUl.m. m s to 1 o t o 040 -r -r icy -r -r to -r 10'-r oxo 11•-r 11'-r 1 2* -r 111-21 ill -2" 111- w o 11'$' 11'-z' 11--r 10'$- la -1o• 10'-6' 13-0' 13�• 13 6' 13-0" 13-r 12* -7' T -S- T -S r-5- T-5' TS• TS' B 3' 8•-3• 8.3• 8'3- 8'3• 8'3• comrc .020 � 6'57' SS• V-5' 6•-3' 6--2* 6'-1• T$• T -r T$• T-5• T-6' T -r °' 0) T 3" 8--3• 8'3 83• 83• 8'3• S -g 8'-9• 8•-9• 8'-9• 024 024 T 4' T-3 T-3' T-1' T-0' 6-11'50 8'-9• 8-r 8'-r 8' S•t• p W eo g-1- 9'-1• 9-1- 9-1- 9'-1• 9'-1" 9$- 9-8 9•$• 9'$• 032 032 mr4r, 0 8'-9' s -r 8'$' 9-s- 6-4• 8'3• 10"4• 1x37 1x37 la -1'• a w IL x 9'-9- 9'-91 9'-9• 9'-W 9'-9' 9•-9' r--040 10�' 1 a 4- 10�' 10�' g In .D40 9'-10' 9•-9• 9'-9' 9-5'''''''•''Z. 9p • • HO„'EAS I. '•.R` CAMPBELL :fl t2�`(- z gip: - m r•� CIVIL ,=�c �ka.�184�� • THCftV—q TRAY CAMPOE” �RAF_TER SPANS-FORyOPEN=L-ATTICE STRUCTURE -S- 1=1.0%1=20:/_130 -MP -H EXP. B-& C- J ' 0 z W zz- :w- 29' -8" F w g b o5S �a~DU aQa "a o J 2 ZO J W Wo�a W 2 ¢ U U z i Jaz M- U U an e2 o� �a �a N� O " "R OR oQ >o _x J Z WJ n OV QW W fe�F Jug y U �S n E 0 m e �Z-�$ a?Wm y U 0 0 FOOTNOTE: "SAMPLE" z r++aa� FIGURE INDICATES o m z ATTACHED 0:) -j r FIGURE INDICATES 4e m g FREESTANDING a o m W z+ o� it O rr W W O W a W o.o4r 8.0' BS 0.024' 6.S 0.024' 0.032" 0.03r 0.04r o.oar 1-�2.0'��X�2.0'-'-I * 3"x8" RAFTER * 2"x6.5" RAFTER *DBL. 2"x6.5" RAFTERS ALUM. ALLOY 3004-F136 OR ALUM. ALLOY 30044id6 ALUM. ALLOY 3004136 OR EQUAL OR EQUAL EQUAL z Z 3" x 8" RAFTER z Z Z DBL. 2" x 6 1/2" RAFTER •'7' Ulu 110 MPH 120 MPH 130 MPH '•T" a � 110 MPH L--l-20-MPH— 130 � 130 MPH a � 110 MPH 120 MPH 130 MPH LUSL (IN.) oaoz EXP. B EXP.0 EXP. B EXP.0 EXP. B EXP.0 LUSL (IN.) � o �. B EXP.0 EXP. B I,-EXP.C,. EXP. B EXP.0 LUSL (IN.) N o EXP. B EXP.0 EXP. B EXP.0 EXP. B EXP.0 16" 29'-8" 29'-6" 29'-8" 28'-9" 29'-3" 26'-3" 16" 16'-0" 15'-10" 16'-0 15'-9" 13'-8" 16" 22'-0" 22'-4" 22'-6" 21'-1" 22'-2" 19'-2" 26'-3" 26'-3" 26'-3" 26'-3" 26'-3" 25'-T --- � 14'-2"14'-2" 14'-2" 13'-g" 10 .042 .024 24" 24'-2" 24'-1" 24'-2" 23'-6" 24'-0" 21'-0" � ~� 13'-1" 13'-0" 13'-1" ` 12'-10" 11'-2" 24" 18'-4" 18'-3" 18'x" 1 T-3" 18'-2" 15'-8" 21'-0" 21'-6" 21'-6" 21'-6" 21'-6" 21'-0" � 11'-T 11'-T 11'-T 11'-7" 11'-7" 11'-3" 16'-3" 16'-3" 16'-3" 16" 23'-0" 23'-0" 23'-0" 23'-0" 23'-0" 22'-g" 16" 2U',-3" 20'-2" 20'-3" 19'-8" 20'-1" 18'-2" 16" 28'-7" 28'-6" 28'-7" 27'-9" 28'-3" 25'-7" 20 .042 21'-10" 21'-10" 10 .032 18'-0" 17'-7" 10 .032 25'-3" 25'-3" 25--3- 2V-10""i 25'-3" 25'-3" 24'-8" 24' 18'-9" 18'-9" 18'-9" 18'-9" 18'-9" 18'-9" 24" 16'-T 16'-6" 16'-T 16 16'-4" 14'-10" 24" 23'-4" 23'-3" 23'-4" 22'-8" 23'-1" 0'-10" 1 T-10" --1r T-10" 17'-10" 17'-10" 17'-10" 17'-10" 14'-8' 14'-8" 14'-8" 14'-8" 14'-8" 14'-4" 20'-8" 20'-8" 20'-8" 20'-8" 20'-8" 20'-2" 16" 19'-8" 19'-8" 19'-8" 19'-8" 19'-8" 19'-8" 16" 24'-6" 24'-4" 24'-6" 23'-9" 24'-3" 23'-2" 16" 34'-7" 34'-4" 33'-T 34'-2" 32'-8" 25 .042 21'-6" 21'-0" 21'-6" 21'-2" 21'-3" 20'-8" .042 21'-9" 21'-9" 21'-9" 21'-9" 21'-9" 21'-2" .042 30'-0" 30'-8" 30'-8" 30'-8" 30'-8" 29'-10" 24" 16'-1" 16'-1" 16'-1" 16'-1" 16'-1" 24" 20°-1" 20'-0" 20'-1" 19'-6" 19'-9" 19'-0" 24" 28'-2" 28'-1" 28'-2" 27'-4" 2T-10" 26'-8" 1T -T 17'-T 1T -T 17'-4" 17'-0" 16'-10" 17'-9" 17'-9" 1T-9" 1T-9" 17'-9" 17'-3" 25'-1" 25'-1" 25'-1" 25'-1" 25-1" 24'-4" 16' 18'-1" 18'-1" 18'-1" 18'-1" 18'-1" 18'-1" 16" 12'4" 12'-4" 12'x' 12'-4" 12'-x" 12'-4" 16" 1T-4" 17'-4" 17'-4" 17'x" 17'-4' 17'-3" 19'-1" 19'-1" 19'-1" 19'-1" 19'-1" 19'-1" •?1'-g" 11'-9" 11'-9" 11'11'-9" 11'16'-7" 16'-7" 16'-7" 16'-7" 16'-7" 16'-7" 30 .042 24" 13•_9" 13'-9" 13'-9" 13'-9" 13'-9" 13'-9" .024 24" 10'-2" 10'-2" 10'-2" 10'-2" 10'-2" 10'-1" .024 24" 14'-2" 14'-2" 14'-2" 14'-2" 14'-2" 14'-2" 15'-T 15'-7" 15'-7" 15'-7" 15'-7" 15'-T 9'-8" 9'-8" 9'-8" 9'-8" 9'-8" 9'-8" 13'-T 13'-7" 13'-7" 13'-7" 13'-7" 13'-7" 16" 15'-10" 5'-10" 15'-10" 15'-10" 15'-10" 15'-10" 16" 1.5'�-8" 15'-8" 15'-8" 15'-8" 15'-8" 15'-8" 16" 22'-1" 22'-1" 22'-1" 22'-1" 22'-1" 22'-0" 16'-8" 16'-8" 16'-0" 16'-8" 16'-8" 16'-8" 15-0" 15'-0" 15'-0" 15'-0" 15'-0" 21'-1" 21'-1" 21'-1" 21'-1" 21'-1" 21'-1" 40 -042 20 .032 20 .032 24' 12'-1" 12'-1" 12'-1" 12'-1" 12'-1" 12'-1" 24" 12'-'10" 12'-10" 12'-10" 12'-10" 12'-10" 12'-9" 24" 18'-1" 18'-1" 18'-1" 18'-1" 18'-0" 13'-8" 13'-8" 13'-0" 13'-8" 13'-8" 13'-8" 1?_' -3" 12'-3" 12'-3" 12'-3" 12'-3" 12'-3" 17'-3" 17'-3" 17'-3" 17'-3" 17'-3" 17'-3" 16" 13'x" 13'-x" 13'x" 13'x" 13'x" 13'x" 16" 10'-.0" 19'-0" 19'-0" 19'-0" 19'-0" 18'-10" 16" 26'-8" 26'-8" 26'-8" 26'-8" 26'-0" 26'-7" 50 .042 15'-0" 15'-0" 15'-0" 15'-0 15'-0" 15'-0" .042 .042 25'-6" 25'-6" 25'-0" 25'-6" 25'-6" 25'-6" 24' 10'-3" 10'-3" 10'-3" 10'-3" 10'-3" 10'-3" 24" 15'-6" 15'-6" 15'-6" 15'-6" 15'-0" 15'-6" 24" 21'-10" 21'-10" 21'-10" 21'-10" 21'-10" 21'-9" 11'-2" 11'-2" 11'-2" 11'-2" 11'-2" 11'-2"-9" 14'-9" 14'-9" 14'-9" 14'-9" 14'-9" 20'-10" 20'-10' 20'-10" 20'-10" 20'-10" 20'-10" 16" 10'-7" 10'-7" 10'-7" 10'-7" 10'-7" 10'-T 16" 15'-10" 15'-10" 15'-10" 15'-10" 15'-10" 15'-10" * NOTE: SINGLE RAFTERS SPACED 16" O.C. MAY BE USED AT .024 11'-7" 11'-T 11'-T 11'-6" 11'-6" 11'-2" .024 16'-3" 16'3" 16'-1" 2" 15'-8" 32' O.C. WHEN DOUBLED AND SINGLE RAFTERS SPACED 24" 8'-1" B.A. 8'-1' 8'-1" 8'-1" 8'-1" 24" . 13'-4" 13'-4" 13'x" 13'-2" 13'-3" 12'-9" 24' O.C. MAY BE USED AT 48" O.C. WHEN DOUBLED. g'-6" g'-0" g'-0" g'_2" 9'-3" 9'-3" 9'-3" 9'-3" 9'-3" 9'-3" 16" 14'-4" 14'-4" 14'-4" 14'x" 14'-4" 14'-4" 16" 20'-2" 20'-2" 20'-2" 20'-2" 20'-2" 20'-2" 25 .032 14'-9" 14'-9" 14'-9" 14'-6"2" 25 .032 20'-9" 20'-9" 20'-9" 20'-6" 20'-7" 19'-10 24" 11'-1" 11'-1" 11'-1" 11'-1" 11'-1" 24„ 16'-7" 16'-7" 16'-7" 16'-7" 16'-7" 16'-7" 12'-1" 11'-10" 12'-0" 17'-0"16'-8" 16'-9" 16'-3" 16" 17'x" 17'-4" 17'-0" 17'-4" 17'-4" 17'-4" 16" 24'-6" 24'-6" 24'-6" 24'-0" 24'-0" 24'-6" .042 1T-9" 17'-9" 17'-9" 17'-7" 17'-8" 17'-1" .042 25'-1" 25'-1" 25'-1" 25'-1" 25'-1" 25'-1" 24" 13'-3': 13'-3" 13'-3" 13'-3" 13'-3" 13'-3" 24" 20'-0" 20'-0" 20'-0" 20'-0" 20'-0" 20'-0" 14'-T 14'-T 14'-4" 14'-6" 14'-0 ihlnkPeQlpuralUrtIUAF'MV 01 9 51521-1 4 SuDrtltttd11521-14 A 5.Wr9, 8/L72014 1135:47 AM, C;umrut writer, " 20'-6" 20'-6" 20'-6" 20'-6" ihlnkPeQlpuralUrtIUAF'MV 01 9 51521-1 4 SuDrtltttd11521-14 A 5.Wr9, 8/L72014 1135:47 AM, C;umrut writer, A. n 10F AS L .0 CA[Oi9 'BELL • n Exp: 12 ]q' : m r'• CIVIL 0l • -i1 �ko.�iPl;ti� THOMAS IRAY C .pBaL MINIMUM NUMBER OF FASTENERS FOR ROOF PANEL TO SUPPORTING BEAM & WALL HANGER Y _ FOR ATTACHED AND -FREESTANDING -SOLID COVERS TABLE 1 - TABLE 2 TABLE 3 7 (2) 211x6 %2" AND WALL HANGERS, 3"x8" AND EXTRUDED AND 3"x8" WITH 6 %2" ROLL FORMED BEAMS STEEL HEADERS STEEL INSERT HEADERS NUMBER OF NO. 14 TEK OR SMS SCREWS NUMBER OF NO. 14 TEK OR SMS SCREWS NUMBER OF NO.14 TEK OR SMS SCREWS ri- PER FOOT OF BEAM LENGTH PER FOOT OF WALL HANGER AND BEAM LENGTH ;� F PER FOOT OF BEAM LENGTH co � 110 MPH 120 MPH 130 MPH 110 MPH 120 MPH 130 MPH 9 110 MPH 120 MPH 130 MPH EXP. B EXP. C EXP. B EXP. C EXP. B EXP. C ~ EXP. B EXP. C EXP. B EXP. C EXP. B EXP. C ~ EXP. B EXP. C EXP. B EXP. C EXP. B EXP. C 5 1 1 1 2 1 2 1 2 1 2 2 2 5' 1 1 1 1 1 '---2- 2 1 2 1 2 5' 1 1 1 1 1 1 1 1 1 1 1 1 6' 1 2 1 2 1 2 2 2 2 2 2 3 6' 1 1 1 2 1 2 1 2 1 2 2 2 6' 1 1 1 1 1 1 1 1 1 1 1 1 7' 1 2 1 2 1 2 2 3 2 3 2 3 7' 1 2 1 2 1 2 2 2 2 2 2 2 7' 1 1 1 1 1 1 1 1 1 1 1 2 1•2 2 2 2 2 � 1 1 2 2 2 2 8 2 2 2 3 3 3 $ 2 2, 2 2 3 3 8% —1--l!1 1 1 1 1 2 1 1 1 2 9' 2 2 2 2 2 2 g1 1 2 2 2 2 2 9' 1 1 1 1 1 1 • 2 3 3 3 3 4 2 2 2 3 3 3 1 1 1 2 2 2 10' [3_- 2 2 3 2 3 2 3 2 3 3 4 10' 1 2 2 2 2 2 2 3 2 3 2 3 10' 1 1 1 2 1 .2 1 2 -- 2 j—_21 11' 2 2 2 2 2 3 11. 2 2�33 2 2 3 11' 3 3 3 4 4 4 2 3 3 3 1 1 1 2 1 2 1 2 1 2 2 2 12' 2 3 2 3 3 3 3 4 3 4 3 5 12' 2 2 2 3 2 3 2 3 2 2 3 4 12' 1 2 1 2 1 2 1 2 1 2 2 2 2 2 2 3 3 3 ' 2 2 .2 3�3--!�- 3 3 13 3 4 4 4 4 5 13 2 3 3 3 4 13 1 2 1 2 1 2 1 2 1 2 2 2 FOOTNOTE: "SAMPLE" FIGURE INDICATES ATTACHED —,a FIGURE INDICATES FREESTANDING ThlnkPadM)uralum'JAPMO 0195%5.21-14 SubMRM115-21-14 A S.dwg, 827/2014 1138:52 AM, CutePOF Wrfter, F� } N rr to m j? LL. U QZw� W Nm >>fort aaop >p0.< U�a,V oa♦: axiom acmm c� zea u1�w„ g_2w S;wfa H 0, V o C a W � .� W IL 4 y r-H-'-omf A S I. CAMPBELL • T )+ ; z Exp: • m CIVIL V., �,,�'o.•1a��a 6.5" ROLLFORM A GUTTER FASCIA ALUM. ALLOY 3004-H36 SPLICE WHERE 0.075" Trp. B MAG BEAM ALUM. ALLOY 6063-T6 DPBCL�2" x6.5"x0.042"U. ALLOY 3004-H36 OR EQUAL J DBL.2"x6.5"x0.032" ALUM. ALLOY 3004-H36 OR EQUAL T=12 OR 14 GA, A653 SS GRADE 50 G60 .04r TYP. SPDC WHEF OCCUF 0.[ r 0.042' TYP. HEADER BEAM GUTTER EXT. CLIP 4"1 -BEAM ALUM. ALLOY 6063-T6 TYPES SPLICE WHERE OCCURS - 1.065' Trp. �ALL)M. 4.5" MAG GUTTER ALLOY 6063-T6 T=12 GA. ASTM A653 SS GRADE 50 G-60 3.0• .03r ALUM. I F� --Vr 3" SQ.x0.032" ALUM. BEAM � W/ 12 GA. STL. "U" CHANNEL AM653 SS GRADE 50 G60 T=12 OR 14 GA. ASTM A653 SS GRADES G60 0.625' INSERT WHERE OCCURS 0.110' TYP. T=0.125' ALUM ALLOY 6063T6 7.0" 7" I -BEAM r ALUM. ALLOY 6063-T6 V W/ 1 "C" INSERT ALUM. ALLOY 6063-T6 W/ 2 "C" INSERTS fl ALUM. ALLOY 6063-T6 NOTE: WHERE'C' INSERT OCCURS AS SHOWN IN SPAN TABLES, IT SHALL BE INSTALLED THE FULL LENGTH OF THE 7' I -BEAM. 3" SQ. ALUM. POST C' ALUM. ALLOY 3004-H36 -.._DBL. 3"x8"x0.042" BEAM...- . XI 10'-0" MAMUM. W/ DBL.GA.STL.INSERT 3"x8x0.042" BEAM EACH INTERIOR COLUMN WHERE 3 ALUM. Asooa-H3s I I I I 1- — 3.0.4— —40 ----}---3.o--I MAXSTM M W/ 14 GA. STL. INSERT 3 GRADE 50 G60 OR EQUAL 3"x8"x0.042" BEAM K MALUM. ALLOY 3004-H36 I DBL. 3"x8"x0.042" BEAM ALUM. ALLOY 3004-H36 DBL. 3"x8"x0.042" BEAM THOWAAs RAY ; OR EQUAL P W/ DBL. 12 GA. STL. INSERT ALUM. ALLOY 3004-H36 N ASTM A653 GRADE 50 G60 NOTE WHERE 12 AND 14 GA STEEL INSERTS OR EQUAL OCCUR AS SHOWN IN THE SPAN TABLES, NOTE WHERE 12 AND 14 GA. STEEL INSERTS OCCUR AS THEY SHALL BE INSTALLED THE FULL LENGTH SHOWN IN THE SPAN TABLES, THEY SHALL BE INSTALLED OF THE 3'x8' BEAM. THE FULL LENGTH OF THE 3'c8" BEAM. ThinkPadouralumVAPMO 0195\5-21-14 SubmtttaR1 21-14 A 5A^j, 827201411:4138 AM. CutaPDF Wrbr, SPDC WHEF OCCUF 0.[ r 0.042' TYP. HEADER BEAM GUTTER EXT. CLIP 4"1 -BEAM ALUM. ALLOY 6063-T6 TYPES SPLICE WHERE OCCURS - 1.065' Trp. �ALL)M. 4.5" MAG GUTTER ALLOY 6063-T6 T=12 GA. ASTM A653 SS GRADE 50 G-60 3.0• .03r ALUM. I F� --Vr 3" SQ.x0.032" ALUM. BEAM � W/ 12 GA. STL. "U" CHANNEL AM653 SS GRADE 50 G60 T=12 OR 14 GA. ASTM A653 SS GRADES G60 0.625' INSERT WHERE OCCURS 0.110' TYP. T=0.125' ALUM ALLOY 6063T6 7.0" 7" I -BEAM r ALUM. ALLOY 6063-T6 V W/ 1 "C" INSERT ALUM. ALLOY 6063-T6 W/ 2 "C" INSERTS fl ALUM. ALLOY 6063-T6 NOTE: WHERE'C' INSERT OCCURS AS SHOWN IN SPAN TABLES, IT SHALL BE INSTALLED THE FULL LENGTH OF THE 7' I -BEAM. .03r ALUM 3" SQ. ALUM POST r,.--'\3- ALUM. ALLOY 3004-H36 3" SQ. ALUM. POST C' ALUM. ALLOY 3004-H36 I 2 87sEACH NOTE: HEADERTOP AND BOTTOM FLANGES HALL E CUT AT XI 10'-0" MAMUM. ra 3"x8x0.042" BEAM EACH INTERIOR COLUMN WHERE 3 4--3.0-� I I I I 1- — 3.0.4— —40 ----}---3.o--I MAXSTM M W/ 14 GA. STL. INSERT 3 GRADE 50 G60 CUT FLANGES AOR MORE TTEND CUFL DO COUMNS.OT 3"x8"x0.042" BEAM K MALUM. ALLOY 3004-H36 I DBL. 3"x8"x0.042" BEAM ALUM. ALLOY 3004-H36 3"x8"x0.042" BEAM W/ 12 GA. STL. INSERT OR EQUAL OR EQUAL N ASTM A653 GRADE 50 G60 NOTE WHERE 12 AND 14 GA STEEL INSERTS _ . OCCUR AS SHOWN IN THE SPAN TABLES, THEY SHALL BE INSTALLED THE FULL LENGTH OF THE 3'x8' BEAM. COLUMN / POST TYPES .03r ALUM 3" SQ. ALUM POST r,.--'\3- ALUM. ALLOY 3004-H36 3" SQ. ALUM. POST C' ALUM. ALLOY 3004-H36 HEIGHT LIMITED TO3" SQ. STEEL POST XI 10'-0" MAMUM. F ASTM A653 GRADE 50 CP60 o.oza' ' 0.03r 0.04r tm PLASTIC te PLUGS 010 SMS @24'OX EA SIDE N3" SQ. ALUM. POST WITH SIDEPLATES ALUM. ALLOY 3004-1-136 0.075' -Di TYP.30 F+-3.0•--�I E MAG POST ALUM. ALLOY 6063-T6 SQ. STEEL POST ASTM A500 GRADE B E 8 H E iii b (■ m U. U � V Q Z W m } ] Qy � W�U. jaa� 0xLu Og4 m IL 0 0 Z . Ld Lu mL� ; $'u Linu =3"SQ.xt=0.188" =3"SQ.xt=0.250" IH =3"SQ.xt=0.313" =4 SQ.xt=0.188' =4"SQ.xt=0.250" SQ. STEEL POST ASTM A500 GRADE B E 8 H E iii b (■ m U. U � V Q Z W m } ] Qy � W�U. jaa� 0xLu Og4 m IL 0 0 Z . Ld Lu mL� ; $'u Linu O_ • 01, AS I. O CAMPBELL •-n (Zy EXP ­ ;2 ,c 0 - CIVIL I�Ip •184 �h»aRt,A THOMAS IRAY ThlnkPad\DuralumUAPMO 019515.21-14 Submit A 0.024' 6.S 0.032' 0.042' 1 --2.0'—i * 2"x6.5" RAFTER * DBL. 2"x6.5" RAFTERS ALUM. ALLOY 3004406 ALUM. ALLOY 3004-H36 OR OR EQUAL EQUAL RAFTER SPANS FOR OPEN LATTICE STRUCTURES 110/120/130 MPH -Z a o uai o 2" X 6 1/2" RAFTER Z • • = ` �" _ z a o of o DBL. 2" x 6 1/2" RAFTER WSL "T^ (IN) 1 LUSL "7- ��N) 110 MPH 120 MPH 130 MPH EXP. B EXP.0 EXP. B EXP.0 EXP. B, EXP.0 EXP B EXP.—C EXP. B EXP.0 EXP. B EXP.0 024 O_ • 01, AS I. O CAMPBELL •-n (Zy EXP ­ ;2 ,c 0 - CIVIL I�Ip •184 �h»aRt,A THOMAS IRAY ThlnkPad\DuralumUAPMO 019515.21-14 Submit A 0.024' 6.S 0.032' 0.042' 1 --2.0'—i * 2"x6.5" RAFTER * DBL. 2"x6.5" RAFTERS ALUM. ALLOY 3004406 ALUM. ALLOY 3004-H36 OR OR EQUAL EQUAL RAFTER SPANS FOR OPEN LATTICE STRUCTURES 110/120/130 MPH -14 A 5.41Wg, 6WrM14 11:41 W AM, UMP'Ur, nraur, FOOTNOTE: 'SAMPLE" FIGURE INDICATES ATTACHED FIGURE INDICATES FREESTANDING EXP. B & C a W w Z zio W W� o'er (OR< y U QU M Y J W J W U W 9 Q IW W U f K U U z O c r<� W 0 U as e^ 00 Cl N ,D • N O O � O " ■ z in o ni w °C J Z W J CL OV Ir Ir LL MW U Q0F a U V .6 J c 8 IL <W �wm Waa� OX.zg L) Z' % O�Qa r mm a0�� Liz '. Lzj H-2, W W U 0, n CID LL o W CO i W Q y -Z a o uai o 2" X 6 1/2" RAFTER Z • • = ` �" _ z a o of o DBL. 2" x 6 1/2" RAFTER WSL "T^ (IN) 110 MPH 120 MPH 130 MPH LUSL "7- ��N) 110 MPH 120 MPH 130 MPH EXP. B EXP.0 EXP. B EXP.0 EXP. B, EXP.0 EXP B EXP.—C EXP. B EXP.0 EXP. B EXP.0 024 16" 9'-9" 10'-3" 9'-9" 10'-3" 9'-9" 10'-3" 9'-9" 10'-3" 9'-9" 10'-3 9'-9" 10'-3 024 _ 16--1-6" 14'-8" 14'-8" 14'-8" 14'-8" 14'-8" 14'-8" 14-6 14'-6" 14'-6" 14'-6" 14'-6" 24" T-0" T-0" 7'-6" 7'-6" 7'-6" T-6" 8'-6" 8'-6" S'-6" 8'-6" 8'$" 24" 11'-2" 11'-2" 11'-2" 11'-2" 11'-2" 11'-2" 11'-10 11'-10" 11'-10" 11'-10" 11'-10" 11'-10' .032 16" 13'-1" 13'-1" 13'-1" 13'-1" .032 16" 18'-4" 18'-7" 18'-7" 18'-7" 18'-7" 18'-7" 30 30 24" 10'-2" 10'-2" 10'-2" 10'-2" 10'-2" 10'-2" 24" 15'-3" 15'-3" 15'-3" 15'-3" 15'-3" 15'-3" 10'-8" 10'-8" 10'-8" 10'-8" 10'-8" 10'-8" 15'-1" 15'-1" 15'-1" 15'-1" .042 16" 16'-0" 15'-9" 16'-0" 15'-9" 16'-0" -15'-9" 16'-0" 15'-9" 16'-0" 15'-9" 16'-0" 15'-9" .042 16" 22'-7" 22'-7" ��-2" 22'-7" 22'-2" 22'-7" 22'-2" 22'-7" 22'-2" 22'-7" 22'-2" 24" 12'-3" 12'-3" 12'-3" 12'-3" 12'-3" 12'-3" 12'-10 12'-10 12'-10 12'-10 '12'-1 12'-10 24" 18'-0" 18'-6" 18'-6" 18'-6" 18'-6" 18'-2" 18'-2" 18'-2" 18'-6" 16" 8'-0" '-1" 8'-0" 9'-1" 8'-0" 9'-1"9'-1" 8'-0" 8'-0" 9'-1" 81-0. 9'-1" 024 16" 2'-10" 12'-8" 2'-10" 12'-8" 2'-10" 12'-8"12'-8" 2'-10"024 12'-8"24" 6'-2" 6'-2" 6'-2" 6'-2" 6'-2" 6'-2' T-2" 7'-2" 7'-2" 7'-2" 7'-2" 24" AIZ-10"2'-10" 9'-10" 9'-10" 9'-10" 9'-10" 10'-4" 10'-4" 10'-4" 10'x" 9'-10"T-2" 10'-4"10'-10" 40 .032 16" 10'-10" 11'-6" 10'-10" 10'-10" 10'-10" 10'-10" 40 .032 16" 16'-4" 16'-1" 16'-4" 16'-1" 16'4" 16'-1" 16'-1" 6'-4" 16'-4" 24" 8'-3" 8'-3" 8'-3" 8'-3" 8'-3" 8'-3" 9'-4" 9'-4" 9'�" 9'-4" 9'-4" 9`1t" 24" 12'-6" 12'-6" 12'-6" 12'-6" 12'-6" 13'-2" 13'-2" 13'-2" 13'-2" 13'-2" 12'-6" 13'-2" .042 16" 13'-2" 13'-2" 13'-2" 13'-2" 13'-9" 13'-2" 13'-9" 13'-2" 13'-9 .042 16" 19'-9" 19'-4" 19'-9" 19'-4" 19'-9" 19' 4" 19'-9" 19'-9" 19'-9" 24" 10'-9" 10'-9" 10'-9" 10'-9" 10'-9" 10'-9" 11'-3" 11'-3" 11'-3, 24" 16'-2" 16'-2" 16-2" 16'-2" 16'-2" 16'-2" .024 16" 7'-3" 8'-2" T -3-T-3- 8'-2" 8'-2"8'-2" T-3" 7'-3" 8'-2" 7'-3" $'-2" .024 16" 10'-10" 11'-4" 10'-10" 11'-4" 10'-10" 11'-4" 10'-10" 11'-4" 10'-10" 11'-4" 10'-10" 11'-4" 24" 24" 5'-2" 5'-2" 5'-2" 5'-2" 5'-2" 5'-2" 5'-9" 5'-9" 5'-9" 5'-9" 5'-9" 24" 8'-3" 8'-3" 8'-3" 8'-3" 8'-3" 9'-4" 9'-4" 9'-4" 9'-4" 9'-4" 8'-3- 9'-4" .032 16" 9'-9" 10'-3" 9'-9" 10'-3" 9'-9" 10'-3" 9'-9" 10'-3" 9'-9" 10'-3" 9'-9" 10'-3" .032 16" 14'-8" 14'-6" 14'-8" 14'-0" 14'-8" 14'-6" 14'-8" 14'-8" 14'-8" 50 50 24" 7'-0" T -W T-0" 7'-0" T-0" T-0" '-4" 8 8'-4" 8'-4" 8'-4" , 8'-4" 24„ 11'-3" 11'-3" 11'-3" 11'-10" 11'-3" 11'-10" 11'-3" 11'-3" .042 16" 12'-6" 12'-6" 12'-6" 12'-6" 12'-6" . 12'-6" 042 16" 17'-9" 17'-6" 17'-9" 17'-6" 17'-9" 17'-6" 17'-9" 17'-6" 17'-9" 17'-6" 17'-9" 17'-6" 24" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 10'-2" 10'-2" 10'-2" 10'-2" 10'-2" 24" 13'-7" 13'-7" 13'-7" 13�131-7"_'3,13'-7"10'-2" 14'-3" 14'-3" 14'-3" -14 A 5.41Wg, 6WrM14 11:41 W AM, UMP'Ur, nraur, FOOTNOTE: 'SAMPLE" FIGURE INDICATES ATTACHED FIGURE INDICATES FREESTANDING EXP. B & C a W w Z zio W W� o'er (OR< y U QU M Y J W J W U W 9 Q IW W U f K U U z O c r<� W 0 U as e^ 00 Cl N ,D • N O O � O " ■ z in o ni w °C J Z W J CL OV Ir Ir LL MW U Q0F a U V .6 J c 8 IL <W �wm Waa� OX.zg L) Z' % O�Qa r mm a0�� Liz '. Lzj H-2, W W U 0, n CID LL o W CO i W Q y 1 ' 1 THOT.�AS•IVr��i' 1 CA11APSELL •- Exp: IZ 1+ : m tv CIVIL .• as THDIVAS [RAY CAMPLELL . ThinkPadlDuralum'JAPMO 01955-21-14 Submt[taI5-21-14 A 5.dwg, 827=1411:45:12 AM, CutePDF Writer, EXISTING LEDGER OR WALL HANGER & EAVE CONNECTION DETAILS �_ NOTE: WHERE COVER CONSTRUCTION INCLUDES DESIGN (E) WALL COVER 3/16 STEEL"" --' 'ISOTE: BRACKET CAN BE LOCATED p A34'FRAMINGANGLE DETAIL A OR K SITE-SPECIFIC ENGINEERING IS LOADS OPENING PROJECTION g" 0 1/4'0 HOl ES,TYP. ANYWHERE ON EAVE. z W SEE TABLE72 REQUIRED TO VERIFY ADEQUACY OF THEEXISTING 10, 20 psf > t3 > 1B 0 NOTE: PROVIDE WATER w z Y r FASTENERS, SEE TABLE 3 STUD WALL FRAMING WHERE ONE OR MORE OF THE 0 TYP. AT BRACKET PROTECTION, METAL FLASHING 2x Lj o FOLLOWING CONDMONS OCCUR: 30, 40 & 50 psf > &> IV EVERY CAUCK JOINTS AND SLOPE B z z o 1D . R.F. OR EXT. HANGER O TO DRAIN (OPTIONAL) O 'r CHANNEL, 2X OR 3X EXISTING EAVE ALLOWABLE PROD. TO BEAM OVERHANG � 22 RAFTER BRACKET LEDGER OR WALL HANGER SEE TABLE 1 tai 6 W = j:.. — WITH FASTENERS 1 1/4' (24' MAX) 2R60R 2c8 LEDGER p�j ¢ EXIST. RAFTERS AT PER TABLES 3 &t 2x WOOD STUD OR ¢ ALUM. PANEL 2X OR 3x ALUM. RAFTER 24.O.C. AT ROOF t• CONCRETE WALL RAFTER (3}#14x3112• W. -•� i o w a a EXIST. FASCIA BOARD OVERHANe 3 a w 6 ALLOWABLE PROJ. EXISTING EA 2X FULL,DEPTH WOOD'SCAB, TO BEAM SEE TABLE 1 OVERHANG (24- MAX-) WHERE OCCURS, SEE TABLE 2 NOTE: PLACE'SIKA FLEX' OR SIMILAR MATERIAL BETWEEN BRACKET AND COMP. NOTE: BRACKET MAY BE 0 � z OF o T SHINGLE ROOFING TO PROVIDE SEAL MOUNTED BELOW RAFTER W/ SAME CONNECTIONS. rr w � EAVE CONNECTION : " WALL CONNECTION o A 1. EXISTING ROOF OVERHANG DESIGN LOADS: f -' -: B NOTE WALL LEDGER IS NOMINAL LUMBER SIZE 2'x6' (AT 2Sc6 }4' C ALTERNATE EAVE CONNECTION RDL= 3 psf (MIN) TO 8 psf (MAX) RLL = 20:25.30, 40, & 50 psf MINIMUM RAFTERS), NOMINAL 2•x8' (AT 3-xS- MINIMUM RAFTERS) NOTE: THIS DETAIL IS LIMITED TO RESIDENTIAL INSTALLATIONS 2. EXISTING RAFTER ALLOWABLE.BENDING STRESS IS 1200 psi. OR KILN -DRY WOOD -FILLED 2-x6 Yz OR 3W- ALUMINUM SECTIONS. WITH A 10 psi MAXIMUM DESIGN LOAD. TABLE 2 TYPE AND NUMBER OF FASTENERS REQUIRED AT ROOF PANEL TABLE 4 a,b ANCHORS INSTALLED �o OR RAFTER CONNECTED TO EXISTING ROOF OVERHANG INTO CONCRETE WALLS oa WITH 6 -INCH MIN.THICKNESSo EXISTING MAXIMUM PROJECTION (A)- SIMPSON A34 FRAMING ANCHOR USING SD9112 SCREWS COVER NUMBER AND TYPE FRAMING MEMBER o WIND SPEED (MPH) AND EXPOSURE COVER AT ROOF (B)- (2) SIMPSON A34 FRAMING ANCHORS, EACH SIDE, USING SD9112 SCREWS WITH 2x FULL DEPTH WOOD SCAB LUSL OF FASTENERS LUSL OVERHANG FULL LENGTH OF RAFTER TAIL o �_ °C 110,13 110,C 120, B 120, C 130, B 130, C } � 10 PSF L.L. 20 PSF L.L. 25 PSF S.L. 30 PSF S.L. 40 PSF S.L. 50 PSF S.L. 1 YZ' 0 SIMPSON STRONG -BOLT 2 SS AT 48.O.C. (a,b) w �_ 2" X 4" FULL 26'-0" 26'-0" 26'-0" 25-2" 25'x" 20'-7" 2" x 6" NOTCHED 26'-0" 26'-0" 26'-W 25-7" 25'-4" 21'-2" o WIND SPEED WIND SPEED WIND SPEED WIND SPEED WIND SPEED WIND SPEED m (EXP. B & C) (EXP. B & C) (EXP. B & C) (EXP. B & C) (EXP. B & C) (EXP. B & C) 20 Yz' 0 SIMPSON STRONG -BOLT 2 SS 2"x6" FULL OR 110 120 130 110 120 130 110 120 130 110 120 130 110 120 130 110 120 130 0 26'-0" 26'-0" 26'-0" 26'-0" 26'-0" 26'-0" AT a8• o.c. (a,b) > 2"x8' NOTCHED � co 2"x8" FULL OR 26'-0" 26'-0" 26'-0" 26'-0" 26'-0" 26'-0" 5' (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) 25 y• 0 SIMPSON STRONG -BOLT 2 SS a'~" 6' (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (B) (B) (B) 2"x10" NOTCHED AT 48• O.C. (a,b) III 0 2" x 4' FULL 26'-0" 26'-0" 26'-0" 25'-2" 25'x" 20'-7" W ►- J W 7' (A) I (A) (A) I (A) (A) (A) (A) (A) I (A) (A) (A) (A) (A) (A) (A) (B) (B) (B) 2" x 6" NOTCHED 26'-0' 26'-0" 26'-0" 26'-0" 26'-0" 26'-0" 30 ob, STRONG -BOLT 2 ss 8 (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (B) (B) (B) (B) (B) (B) AT036'IO.C. Fzz c0i 2U 2"x6" FULL OR 2"x8" NOTCHED 26'-0" 26'-0" 2s'-0" 26'-0" 26'-0" 26'-0" 9' (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (B) (B) (B) (B) (B) (B) 40 Y2.0 SIMPSON STRONG -BOLT 2 SS 2"x8" FULL OR 26'-0" 26'-0" 26'-0" 26-0" 26'-0" 26'-0" 10' (A) (A) (A) (A) (A) (A) (A) (A) (A) (B) (B) (B) (B) (B) (B) (B) (B) (B) AT 36' O.C. (a,b) 2"x10" NOTCHED E 11' (A) (A) (A) (A) (A) (A) (B) (B) (B) (B) (B) (B) (B) (B) (B) (B) (B) (B) rJ0 bSTRONG-BOLT 2 SS m m 2" x 4" FULL 26'-0 " 26'-0w 2V -W " 25'-2" " 25'4" 20'-7" 2" x 6' NOTCHED 26'-0" 26'-0 26'-0 26'-0 26'-0" 26'-0" 12'(A) (A) (A) (A) (A) (A) (B) (B) (B) (B) (B) (B) (B) (B) (B) (B) (B) (B) AT24' O.C. ( m LL 25 2"x6" FULL OR 26'-0" 26'-0" 26'-0" 26'-0" 26'-0" 26'-0" TABLE 3 c TYPE AND NUMBER OF FASTENERS REQUIRED AT LEDGER T Q z x 2"x8' NOTCHED AND ROOF PANEL RAIL TO FASCIA -m— 2"x8" FULL OR 2"X8" 26'-0" 26'-0" 26'-0" 26'-0" 26'-0" 26'-0" OR LEDGER TO EXISTING WOOD STUD WALL FRAMING TO TABLES 3 & 4: g o 2"x10" NOTCHED a. EMBED ANCHOR 3" MINIMUM INTO W S LC 2" x 4" FULL 16'-0" 16'-0" 16'-0" 16'-0" 16'-0" 16'-0" (C) - (2)Y4- DIAMETER LAG SCEWS CONCRETE WALL AND INSTALL IN > > a (D) - %" DIAMETER LAG SCREW (E) - %" DIAMETER LAG SCREW ACCORDANCE WITH ESR -3037 W u ? a 2"x 6" NOTCHED 10'-10" 101-10"110'-10' 9'-2" 9'-3" - 2"x6" FULL OR 26'-0" 26'-0" 26'-0" 26'-0" 26'-0" 26'-0" 30 b. USE 3" SQ.xY4" STAINLESS STEEL a 2"x8" NOTCHED WASHER WHEN INSTALLING NEW a o m m } 10 PSF L.L. 20 PSF L.L. 25 PSF S.L. 30 PSF S.L. 40 PSF S.L. 50 PSF S.L. WOOD LEDGER AGAINST EXISTING 2"x8" FULL OR 2"x10" NOTCHED 26'-0' 26'-0" 26'-0" 26'-0" 26'-0" 26'-0" Q I- WIND SPEED WIND SPEED WIND SPEED WIND SPEED WIND SPEED WIND SPEED m � (EXP, B & C) (EXP. B & C) (EXP. B & C) (EXP. B & C) (EXP. & C) (Exp. B & C ) CONCRETE WALL. 2" x 4" FULL 11'-7" 11'-7" 11'-7" 11'-7" 11'-7" 11'-7" c. WHERE, ROOF PANEL RAIL OCCURS,_ Z. ►- - 110 '120 130-1.1-10- .120. • 130 110 120 '130 1101120-1,130, -110 120 130 130' 2" x 6" NOTCHED 151-6' 15'-6" 15'-0" 15'-6" 15'-6" 15'-0" .110-1120 USE Y2" DIAMETER LAG SCREW IN `� g 2"x6" FULL OR 5' (C) (C) (C) (C) (C) (C) (C) (C) (C) (C) (C) (C) (D) (D) (D) (D) (D) (D) 40 LIEU OF (2) Ya" DIAMETER LAG = g B 6' (C) (C) (C) (C) (C) (C) (C) (C) (C) (D) (D) (D) (D) (D) (D) (D) (D) (D) 2"x8" NOTCHED 19'-6" 19'-6" 19'-0" 19'-6" 19'-6" 19'-6" SCREWS. §g g E O c °' ¢ 2"x8" FULL OR 26'-0" 26'-0" 26'-0" 26'-W 26'-0" 26'-0" 7' (C) (C) (C) (C) (C) (C) (C) (C) (C) (D) (D) (D) (D) (D) (D) (D) (D) (D) 2"x10" NOTCHED 8' (C) (C) (C) (C) (C) (C) (D) (D) (D) (D) (D) (D) (D) (D) (D) (E) (E) (E) o 2" x 4" FULL 8'-11 8'-11" 8'-11" 8'-11" 8'-11" 8'-11" p 2" x 6" NOTCHED 12'-1" 12'-1" 12'-1" 12'-1" 12'-1" 12'-1" 9' (C) (C) (C) (C) (C)' (C) (D) (D) (D) (D) (D) (D) I (D) (D) (D) (E) (E) (E) cJ0 19 w 2"x6" FULL OR 15'-3' 15'-3" 15-3" 15-3" 15-3" 15'-3" 10' (C) (C) (C) (C) (C) (C) (D) (D) (D) (D) (D) (D) (E) (E) (E) (E) (E) (E) 2"x8" NOTCHED C °_' 11' (C) (C) (C) (C) (C) (C) (D) (D) (D) (D) (D) (D) (E) (E) (E) (E) (E) (E) 2"x8" FULL OR 2"x10" NOTCHED 20'-9" 20'-9" 20'-9" 20'-9" 20'-9" 20'-9" 12 (C) (C) (C) (D) (D) (D) (D) (D) (D) I (D) (D) (D) (E) (E) (E) (E) (E) (E) ThinkPadlDuralum'JAPMO 01955-21-14 Submt[taI5-21-14 A 5.dwg, 827=1411:45:12 AM, CutePDF Writer, � Oy1ASI. �•S�' CAWS BELL •Q ;2 ' Exp: 12 . m •,c CIVIL 1 B4� �� THO MAS IHAY CAMPBELL HANGER CHANNELS AND MOUNTING BRACKETS ' - FASTENERS, T=.060" TYP. 0 2.740" SEE TABLE 3, SHEET 4 ,W 1.50" SEE TABLE 3 SHEET 8� 30�0• 078 z U j n 1 T=.060" W ALUM. 3004-H36 s3• 06 " "R 0 FASTENERS � m Q 202" FASTENERS. 01(2) DU\. SEE SHEET 4 N� .563 .281• 20' 5.A SEE TABLE 3 SHEET 0 6" U m Nc °° � i< TFASTENIERS CON71N000SA-RAIL OCCURS) ui W o ROOF PANEL Q (WHERE O a w" ri O " LE 3 O6 . ai v z ( 1.500" l FASTENERS, w ALUMALLOY SEESHEET4 FASTENERS, o a z F 1— T5 ALUMALLOY 6063 T6 1.880" SEE TABLE 3, SHEET 4 6063-T6 �60s�ls Y ALUM. ALLOY 6063-T6 0 OROHANGERED O EXTRUDED HANGER / CONNECTION OC I.R. HANGER "H" BRACKET NOTE: THIS CONSTRUCTION IS LIMITED TO 30 psf = a a MAXIMUM. SITE-SPECIFIC ENGINEERING REQUIRED d V AT ROOF LOADS EXCEEDING 30 psf. (3)1/2"0 LAG SCREWS 1 1/2" 10# L.L.=(2)it,f SMS EA_ SIDE o 0 20#,25#,30# LL.=(3)#14 SMS EA. SIDE BEAM SPLICE TO o ° _ #14 SDS, 40#,50# L.L=(4)#14 SMS EA. SIDE OCCUR DIRECTLY OVER 5/8' PJ PLASTIC ' o = K. 3 PER SIDE POST. NOT PERMITTED PLUG WHERE a r 3/4" OR 1 �/2" @ 6 SCREWS I @ 2 -POST UNITS SCREW IS INSIDE W _ 0 J PER SIDE I J 2" x 6 1/2" OR 5" #14 SMS MAY p S" MIN. 3" x 8° ALUM. 3.5" 3.5" ALTERNATE TO 12X' RAFTER 1/4"0 BOLTS � _L 12EE�AC2H 3.5" 3.5" z � 3• 3"x8" ALUM.— 3/4" OR 1 1/2- - — -- — — —__. — 8" BEAM e= z o = a a X r HEADER U -BRACKET � .5" E1 OR ❑2 W liJ EXISTING WOOD STUD FRAMING SEE NOTES w a LL m 3"x8" ALUM. (E) STUCCO BELOW 1 1 6 1/2" SIDEPLATE EA E STUCCO 1/4.0 x 3-1/2"LAG SCREWS LL=10 psf IRAFTER SIDE SEE POST SCHED. 1/2.0 X 3-1/2" LAG SCREWS LL=20.25 and 30 psf #14 SMS EA. SIDE PENETRATION BRACKET 2 EACH 5/8"0 x 3-1/2" LAG SCREWS L.L=40 and 50 psf TOP, MID HEIGHT NOTE: LENGTH OF LAG SCREW SHALL PROVIDE (2" MIN. PENETRATION. INTO EXISTING WOOD STUD) AND BOTTOM. 3"SQ. POST BETWEEN SIDE PLATES E THREADED PORTION OF SHANK COMPLETE NOTE: USE LEDGER WHERE RAFTER SPACING m 9 PENETRATION INTO EXISTING CORNER STUD. EXCEEDS EXISTING STUD SPACING. SEE TABLE 3 SHEET 8. SEE LATERAL FORCE RESISTING SYSTEM, SHEET 11 LL HEADER BRACKET 2 RAFTER TO STUD WALL CONNECTION 3 BEAM TO POST CONNECTION 8 a i U. �qJaa N U U 1 1/2" OR 2•LA7-1ICE #8 S.M.S. #8 S.M.S. EACH SIDE W p „ j ¢ cc> LL ALTERNATE 1/2• DOUBLE RAFTER- EXISTING ALUMINUM MEMBER WITH j a a r BOLT CONNECTION PLAN 2 LATTICE 1 1/2" OR 2" SHEATHING WOOD FILL OR DBL. 3"x8"x0.042 BEAM O z A ALTERNATE: NOMINAL LEDGER (NEW OR EXISTING) OR DBL. 2'x6.5'k0.032•ro.oa2• BEAM UO '� o 4414 S.M.S. EACH RAFTER TO COL SEE NOTE, DETAIL B, a o m CONNECT. (8 TOT.) 2'x6.5' OR 3'x8' RAFTER R 0 =; SHEET 8 Lu - T I o ALTERNATE: 1/2" BOLT y 1•o w _ ,4.5• ... e • • - .ALTERNATE: .- - _ _ .. _ ..n %� _ FASTNERS..SEE TABLE:3, ..- > - - _. .. .... .. .., _-. -_ . - -.-. z+ w ^ z > t i 1" (2} #14 S.M.S. EACH RAFTER �-+ SHEET 8 m TO COLUMN CONNECTION (4 -TOTAL) • 5/8" 0 ACCESS HOLES io ALTERNATE L-POSTNSERTT t t INSTALL 6 - #14 X 3" 0 w • (2}2x6.5' OR ATTACHED) r2-x6.5'SIDEPL:ATE - - ALTERNATE: r 3' SQ. POST LONG SDS @ EACH 3'x 3•STL POST COLUMN (2) -3 -x8 -HEADER FOR FREESTANDING (2},2x6.5" OR (2}3'x8" HEADER ;: EXISTING HEADER TO COLUMN (12 FASTENERS PER (2) -Ir --BOLT ALTERNATE: 1' STUCCO OR EQUAL CONNECTION) a, ,p u_ 3 x3•x0.024" (1) - 1 /2" BOLT OR 2.5' PENE. INTO EACH WOOD STUD O CONNECTOR (2} #14 S.M.S. EACH RAFTER C w ui DBL. RAFTER / DBL. HEADER CONN. 4O STUB COLUMN TO DOUBLE HEADER CONN. O5 LIST. STUCCOT DETAILLEDGER OO DOUBLEHEADER TO O g COLUMN DETAIL ThlnkPad\DuralumMAPMO 019515.21-14 SubmMa115-21-14 A 5Avg, 827201411:44:47 AM, Cul9PDF Writer, li'WAAS I, CAMPBELL Em. ' m c CIVIL T:- OLMS I.RAY CA119PB LL , ' c COLUMN / POST SURFACE MOUNT AND FOOTING EMBEDMENT DETAILS / MIN. NUMBER OF REQ. COLUMNS W W .Z V O n . Z = o W N � � a Q m o w m m r a TABLE 1 TABLE 2 < a ATTACHED ONLY ATTACHED ANDui Z ��STEEL POST ONLY: w 2 Q 'T' BRACKET Q 3 -SO. POST ' FOOTING & ANCHOR BOLTS FREESTANDING ; <ysE POST TYPE IL W1(4)-#14 SMS EA. SIDE OF POST OR 12' M.B. THROUGH POST ALUM. rBRACKET USE WITH ALTERNATE FTG. i �+"�„F, G,; H'l; J OR K <00 POST POST TYPE B,C,D, OR E 1 SINGLE POSTS 1 r M < z POST FOOTING SIZE BOLTS EMBED. cuBE S� 50 16' DEEP 'CUBE FTG. r j Es STEEL. -r BRACKET OR 9" SO. 16' 18" SQ. 12' 12-1?EPTH OF I 1 ¢ Lu 1 BASE PLATE USE WITH 1T -22' cusm (t) (2)-318.0 1 7/8' 20' 21' SQ. 1Y FO,OTING OR j POST TYPE B,C,D,E,F,G,H,J OR K X12' MIN. EMBD. 1 (2}3/8"0 STRONG -BOLT 2 SS SEE TABLE 1 22" 25" SQ. 16" 23' 8 24" CUBED (1) (2}12'0 3114' T_-7- EA. BRACKET TO SLAB. Qi ' • • : 1 I 9 12" MINIMUM DISTANCE TO 24' 28' SO. 20' W EDGE OF SLAB. zs - 30- CUBED (z) (a}t2-e 31/4' 26' 32 SQ. 23' r t I F m 33" MINIMUM DISTANCE FROM 28 35' SQ 25' t -�J' I _ tL ~ m x SLAB CRACK TO COLUMN. d I i 31• - 34- CUBED (2) (4}5B'0 4 IlL Z a (I%- MIN. EMBEDMENT) 30' 39' SQ. 28') co Q $ DID ITH d • 35'- 39' CUBED (2) (4)-314'0 4 3f4' 32' 43" SO. 30" -. ? •- _ ,�,; c Ffl x9 + 34' 47' SQ. 32' LONG, B rb°:; (L Q N O '' Sa POURED CONCRETE W W LAB SHALL BE INFROMh r GOOD CONDITION FOOTING SEE TABLES �' az CUBED (2) (4}3ra'3/4' 0 4 36* 51 • SO 34' OF POST 133 f o ■ J Z ■ z FOR SIZE - ' NOTE BOLTS SHALL BE SIMPSON STRONG -BOLT 2 SS 38' 55' SO. 37" f < K. 3 12' MIN. SEE FOOTING II ()CC -ES ESR -3037) POURED—SQUARE, SEE FTG. O o . IN BEAM SPAN TABLE �Ou�` - 1) MAY USE EITHER STEEL T BRACKET OR 4� 60"SO. 3� CONCRETE 0 SCHEDULE IN BEAM W ALTERNATE FREESTANDING BASE PLATE 42" 64' SO. 41' FOOTING SPAN TABLES�r EXISTING SLAB POSTS TO CONC. FOOTING 2) REOUIRES USE OF ALTERNATE FREESTANDING 69" SO. 43- BASE PLATE. • CUHE FOOTING W13 VY MAS �, SQUARE POST EMBED.w O ATTACHED COVERS ONLY O ATTACHED COVERS ONLY O�INTO FOOTING . W z ' U.Z"J ¢FWO .. ._ '846 4 6 WCi o00uu'c (3}3/4"0 BOLTS Z f rc FOR POST TYPE F, G, H, I, J & K p uim 3" OR 4" SQ. " z 45. INSERT 16" x 0.188" ASTM A500 45.GRADE B m A 9 STEEL LL U T.O.C. ti U e <?W. (4Y SS316 3/4"0 STRONG -BOLT 2 SS w" G STEEL PER ICC -ES ESR -3037 } a ALUM. ALLOY 3.00" OR (4 3/4" EMBEDMENT DEPTH) N 0 2.0" y L�+I a Lu 07 6063-T6 2.40" a A q 7/16"0 HOLE INSERT TO o 1.375" FOR 3/8" MB `�• 2 FLANGES BASE PLATE 3t16• a- 2 o m m O 1/8 APART .75" ASTM A500 GRADE B 2 5" JPLATE -- ^ W 0 INSTALL 1Y2" x 1Y2" x YS" HDG 1'125- o WASHER PLATE AT ANCHORS -. . -.a_ : ..-- _ ...._ . -. _ ._... ;.75• . ... , 75 - S . W v W " " BA E FLARES _ o_..:. 157" TO 3"WIDE EA. 9" SQ. X 5 `_' z g W 1.60" TYP SIDE OF FLANGES 3 w ", 1.5 r� USE FOR 3" OR 4' 1.75" FOR 3" POST, THK BASE 090 TYP. STEEL POSTST T, 4" WIDE FOR 4" POST (ASTM A500 GRADE B STEEL) 5.50.., 1 Y' 6Y" 1 Yi INSTALL 1Y' x 1Yz" x Ye"HDG 1-7/16"0 HOLE WASHER PLATE AT ANCHORS 11 11 FOR 130 MPH q 2- 5/16"0 HOLES & 2-3/8" HOLES NOTE: CONCRETE SLAB ANCHORS SHALL BE TYP. EA. SIDE O w o NOTE: CONCRETE ANCHORS ARE SHOWN IN TABLE 1. WELDED STEEL BASE PLATE 8" DIAMETER SIMPSON STRONG -BOLT 2 SS (ICC -ES ESR -3037)W ALTERNATE FREESTANDING a = ALUM "T" BRACKET C STEEL "T" BRACKET. D BASE PLATE ANCHOR N TNnkPad(DuralumXIAPMO 019515-21-14 Submlttal&21-14 A 5.dwg, 827201411:45x6 AM, CutePDF Writer, mi Na_ C37948 EXP. 03131/1 (o" .0; ASI. CAAI�i'BELI �012 I+ ; Z Exp: , CIVIL ; d •a ko �j gq1� THOMAS TRAY • : CWPOELL LATERAL FORCE RESISTING SYSTEM (LFRS) FOR ATTACHED. COVERS /BEAM SPLICE TO ,,/BEAM OCCUR DIRECTLY OVER 5/8' 0 PLASTIC.. ais i � r 110 MPH Na_ C37948 EXP. 03131/1 (o" .0; ASI. CAAI�i'BELI �012 I+ ; Z Exp: , CIVIL ; d •a ko �j gq1� THOMAS TRAY • : CWPOELL LATERAL FORCE RESISTING SYSTEM (LFRS) FOR ATTACHED. COVERS /BEAM SPLICE TO ,,/BEAM OCCUR DIRECTLY OVER 5/8' 0 PLASTIC.. ais 2"X6.5"X0.032" SIDE•PLATES 5 110 MPH 120 MPH 130 MPH EXP. B EXP. C EXP. B EXP. C EXP. B EXP. C 5' 2 2 2 3 3 3 6' 2 3 3 3 3 4 7' 2 3 3 4 3 4 8' 3 3 3 4 4 5 9' 3 4 4 4 4 5 .10' 3 4 4 5 5 6 11' 4 4 4 5 5 6 12' 4 5 5 6 5 7 13' 4 5 5 • 6 6 1 7 ix Sa� 3 2"X6.5"X0.042"'SIDE PLATES 110 MPH 120 MPH 130 MPH EXP. B I EXP. C EXP. B EXP. C EXP. B EXP. C 5' 2 1 2 2 2 2 3 6' 2 2 2 3 3 3 7' 2 3 3 3 3 4 8' 2 3 3' 4 3 4 91. s 3 3 3 4 4 5 10'- 3 4 4 4 4 5 11' 3 4 4 5 5 6 12' 3 4 4 5 5 5 13' 4 5 4 6 5 i 7 NOTE: 1. MINIMUM NUMBER OF REQUIRED TYPE D COLUMNS AS SHOWN ON SHEET 7. SEE SHEET 7 FOR POST TYPES. 4 RO INSULATE INTERLOCKIt WALL - MANGER ThinkPad0ura um\IAPMO 0195\5-21-14 Submltt W21-14 A 54'rvg, 827201411:4638 POST. NOT PERMITTED PLUG WHERE 0 6 SCREWS I G 2 -POST UNITS SCREW IS INSIDE PER SIDE I .5' #14 SMS MAY ' BE USE AS 3.5' 3.5" ALTERNATE TO 3.5" 3.5' 1/4"0 BOLTS ' S' 8" BEAM OR a i SEE NOTES I I 6 1/2" SIDEPLATE EA. BELOW SIDE SEE POST SCHED. #14 SMS EA. SIDE TOP, MID HEIGHT AND BOTTOM. 3"SQ. POST BETWEEN SIDE PLATES POST SCHEDULE 3" SQ. x .032" + (2)-2" x 6 1/2" x 0.032" 3" SQ. x .032" + (2)-2" x 6 1/2" x 0.042" W/ (6)-#14 S.M.S. EACH SIDE. Efl W/ (8)-#14 S.M.S. EACH SIDE. USE ON CONC. SLAB ONLY USE ON CONC. SLAB OR FOOTING. BEAM TO POST CONNECTION 21 ALTERNATE FOR SOLID -ROOFED ATTACHED COVERS WHERE MINIMUM NUMBER OF REQUIRED COLUMNS (SHOWN AT LEFT) ARE NOT SPECIFIED ROOF PLAN FASTENERS, #14 SMS @ 32.O.C. .ET 4 4 MIN. PER EACH JOINT .r ROLL -FORMED #14 SMS 0 32' O.C. MAX OR IRP (4 MIN. PER PANEL INTERLOCK) OLL-FORMED PANEL ALUMINUM SKID RP TOP 8 BOTT. 0.024' SEE SHEET 4 ROOF HANGER O ROLL -FORMED PANEL INSULATED ROOF PANEL INTERLOCKISEAM NG INTERLOCKING JOINT I z a� W i zZ'p W N W ¢ + f - Q n U GQm w m U m aQa ri0i J W o Q to a c� awe M K U aao �J Z 0 :s H U W 0 U IL �o o� N O :Z .0� W0 CD co M i> FV t, w w w= U W Q 0G • oa LL a. O LL s E 8 E m m� m p U @� VIUZz a�W. M, G 12 W rr Q =Es o -, aim= CL ixix W z+ v CD cm cm v LL O b w IL w 5 m No. C37948 EXP. 03/31/% J'' to, .S Ivr9��`i CA;k BELL Exp. 12- 1+ = Z .m CIVIL �0'. •. ®;=o •184ti I.. ! - --••-. _ THOMAS RAY CA11.pDE L t BEAM TO POST & LATTICE TUBE TO RAFTER CONNECTION DETAILS SPLICE DETAILS 11 BEAM TO POST DETAILS 12 _ BEAM TO POST DETAILS 13 0 SIMPLE SPLICE FULL MOMENT Z 6: OPTIONAL DECORATIVE FASCIA w UA 24' ( WOOD, _ ALUMOR HARDBORD) tj 3` 11,111 3' 1`T 8' `1 Z = o (2#10 S.M.S.@ EA In #12 S.M.S. VALLEY, TMP (12) - 914 xSCL POST (12` SA&S. EACH SIDE OF 3' F2 w (8 TOT. II 0 ALTERNATE: 1�/4 o BOLT W/ WASHER one TYP. THICKNESS = .035 (24 TOT Typ THICKNESS =.035" r=== __ EA SIDE OF 3SQ. POST m w a 6.38' .__ II ti p map f 11 t t ++ t t t+ ++ 'L j 0 w93 ALUM. ALLOY 3004 H36 r. ALUM_ ALLOY 3004-H36 w + a OR 6063-T5 FOR EXTRUDED OR 6063-T5 FOR EXTRUDED =__ __ T O I 1 70 <00 NOTE: USE SIMPLE SPLICE ONLY NOTE: FULL MOMENT SPLICE MAY OCCUR ' I t �•� o a IN ALTERNATE INTERIOR BAYS AT ANY LOCATION EXCEPT AT END BAYS - L _ ± o a NOTCH I -BEAM FLANGE 235'3• SO. POST 1-0 SPLICES - ROLLFORMED & EXTRUDED FASCIAS 1-BEAMALUM ALLOY AS NEEDED TO CLEAR w POST,WEB NOTE: IF SPLICE OCCURS AT ALTERNATE INTERIOR BAYS, A SINGLE 12' SIMPLE CS(6061-T6) ALTERNATE SO. CONNECT PLICE (ONE SIDE OF WEB) MAY BE USED. STL. C -BEAM j TO POST W/ (2) - 518' 0 00 3" TOTAL= (8)-t2-0 BOLTS THRU-AND (3BO5 BS 0 THRU BOLTS 4-014 x 12' S.M.S. EACH SDE OF 3' SO. POST SO. POST (8 -TOTAL) @ T 1.8EAM5 ALTERNATE: ' BOLT W/ WASHER FA SIDE OF 3' SCL Sd POST O O O n ix 0- t3CX UTTER FASCIA o 3AO' 3' SO. POSTG BEAM o 0 2-ar' OR 240' SSTL BEAM SPLICE WHERE 4" OCCURS o o. n'P- H -BRACKET TO POST 14 RAFTER "TAIL" TO GUTTER 15 n. o.a ' NOTE: THIS DETAIL IS LIMITED TO 10, 20 & 30 psf o ALUM. ALLOY 3"x 8" x _042" BEAM, ROOF LIVE AND SNOW LOADS z= 6063-T6 1G LI1-3" SO STEEL OR I Fll-/'— MAG BEAM_ 4•• 1-1:51:AM I- 3'-0' MOMENT CSPLICE T i � No. C37948 EXP. 03/31/% J'' to, .S Ivr9��`i CA;k BELL Exp. 12- 1+ = Z .m CIVIL �0'. •. ®;=o •184ti I.. ! - --••-. _ THOMAS RAY CA11.pDE L t BEAM TO POST & LATTICE TUBE TO RAFTER CONNECTION DETAILS SPLICE DETAILS 11 BEAM TO POST DETAILS 12 _ BEAM TO POST DETAILS 13 0 SIMPLE SPLICE FULL MOMENT Z 6: OPTIONAL DECORATIVE FASCIA w UA 24' ( WOOD, _ ALUMOR HARDBORD) tj 3` 11,111 3' 1`T 8' `1 Z = o (2#10 S.M.S.@ EA In #12 S.M.S. VALLEY, TMP (12) - 914 xSCL POST (12` SA&S. EACH SIDE OF 3' F2 w (8 TOT. II 0 ALTERNATE: 1�/4 o BOLT W/ WASHER one TYP. THICKNESS = .035 (24 TOT Typ THICKNESS =.035" r=== __ EA SIDE OF 3SQ. POST m w a 6.38' .__ II ti p map f 11 t t ++ t t t+ ++ 'L j 0 w93 ALUM. ALLOY 3004 H36 r. ALUM_ ALLOY 3004-H36 w + a OR 6063-T5 FOR EXTRUDED OR 6063-T5 FOR EXTRUDED =__ __ T O I 1 70 <00 NOTE: USE SIMPLE SPLICE ONLY NOTE: FULL MOMENT SPLICE MAY OCCUR ' I t �•� o a IN ALTERNATE INTERIOR BAYS AT ANY LOCATION EXCEPT AT END BAYS - L _ ± o a NOTCH I -BEAM FLANGE 235'3• SO. POST 1-0 SPLICES - ROLLFORMED & EXTRUDED FASCIAS 1-BEAMALUM ALLOY AS NEEDED TO CLEAR w POST,WEB NOTE: IF SPLICE OCCURS AT ALTERNATE INTERIOR BAYS, A SINGLE 12' SIMPLE CS(6061-T6) ALTERNATE SO. CONNECT PLICE (ONE SIDE OF WEB) MAY BE USED. STL. C -BEAM j TO POST W/ (2) - 518' 0 00 3" TOTAL= (8)-t2-0 BOLTS THRU-AND (3BO5 BS 0 THRU BOLTS 4-014 x 12' S.M.S. EACH SDE OF 3' SO. POST SO. POST (8 -TOTAL) @ T 1.8EAM5 ALTERNATE: ' BOLT W/ WASHER FA SIDE OF 3' SCL Sd POST O O O n ix 0- t3CX UTTER FASCIA o 3AO' 3' SO. POSTG BEAM o 0 2-ar' OR 240' SSTL BEAM SPLICE WHERE 4" OCCURS o o. n'P- H -BRACKET TO POST 14 RAFTER "TAIL" TO GUTTER 15 n. o.a ' NOTE: THIS DETAIL IS LIMITED TO 10, 20 & 30 psf o ALUM. ALLOY 3"x 8" x _042" BEAM, ROOF LIVE AND SNOW LOADS z= 6063-T6 1G LI1-3" SO STEEL OR I Fll-/'— MAG BEAM_ 4•• 1-1:51:AM I- 3'-0' MOMENT CSPLICE FASTENERS 1'-0" 4 - #14 SDS m ►a Sew NOTE: IF SPLICE OCCURS AT ALTERNATE INTERIOR BAYS, A SINGLE 12' SIMPLE C -SPLICE (ONE SIDE OF WEB) MAY BE USED. 4' 1.25' 2'-0" 6-#14 SDS FASTENER TO FASCIA - SEE TABLE ra og z 3'-0" 12 - #14 SDS F/ FASTENER TO RAFTER TAILS - SEE TABLE a o Fo FASTENER SPACING = 3l4' OPTIONAL LATTICE TUBES I Z O O O #14 x 12' S.M.S. TOP AT OVERHANG ~ 00i (6}#14 SDS @ EA. SIDE & BOTT. (2) -TOT. d m TOP & BOTT. TOT=24 SPLICE wHERE OCCURS 4.5" 0 11' ROOF PANEL 4 FASTENER 612- TYP. -- 00 GROUP O O ROLLFORMED OR .. EXTRUDED GUTTER ISL ALUM. BRACKET X o g 3"X 3" ALUM. OR #14 S.M.S. @12"O.C. ALUM. ALLOY 16` r STEEL POST FASCIA a i w m p �o 6063 TB —3'-(r 6 12'x2`x.024 2' 1' 'L" SEE TABLE hW- I, 7" I -BEAM RAFTER 5 co MOMENT CSPUCE "U" BRACKET - RAFTER TO BEAM W w 1)/2" SQ. OR 2" LATTICE TUBE 2"x3" LATTICE TUBE P2 LATTICE TUBE TO RAFTER 16 "U" BRACKET - RAFTER TO BEAM 17 o�Z^ "-►3.125" FOR 3 x RAFTER O 2-125* FOR 2 x RAFTER m°0 m ALUM. ALLOY 3105-H25 i 1 12• SQi2�S0., ALUM. ALLOY 3105-H25 OR 2'x3' LATTICE _ " OR31/2'?TYP._..-.,;..-.,.� UUP TO 6'0.C. MAX. -- _ _ ..�_. _ .. ..Z. 1 1/2- t 040" @ 6063-T6 1:50" _ 28" _ _ _ _ W g ' = 016 — .018 (6)-#14x SCBRACKET TO1/2' MIN. ra a O RAFTER w w o �c n } RAFTER �/ 110 O UA (6) - #14x s/i TEK SCREWS - z 2.7 w BRACKET TO BEAM Q = rn TNnkPadlDuralumUAPMO 0195%,5-21-14 SubmhMIZ-21-14 A 5.dwg, 827/201411:47:17 AM, CuIePDF Writer, m . . Qd '- N.. c3794i. EXP. 03131/ f - I C� ,Q RAS I. 0 CA•VPBELL • -1s to u.. ; Exp:_ . m ,c Od CIVIL w _ •a - No.1841A . iO�b;1L E,y ��• 415�202/�� THCMAS IRAY CAMPBELL ThinkPad\Duralum\IAPMO 0195\5-21-14 Submit , ' CLEAR SPAN (FT.) HOW TO DETERMINE TRIBUTARY WIDTH TO WALL HANGERS LEDGERS AND SUPPORTING BEAMS • 6 7 8 9 10 11 12 13 14 ,. ... 17 18 19 - .. . _ 0 W 3 4 4 5 5 6 6 7 7 t 8 9 9 10 10 W z z Z o 1' 4 5 5 6 6 7 7 8 8 9 9 10 10 11 W N 12 2' S 6 6 7 TRIBUTARY WIDTH TABLE 9 10 10 11 11 a 12 NP 3� _ 7 7 8 8 9 9 10 10 11 11 PROJECTION m NP NP NP q• _ _ _ 9 9 10 10 11 11 12 CLEAR SPAN O.H. o - �mcai NP NP NP NP 5• _ _ _ _ _ 11 11 12 12 NP aao NP NP NP NP NP °a€z 0 W O IL TRIBUTARY TRIBUTARY-- h w 2 ix a o 0 WIDTH 1/2 SPAN +O.H. It rt 2-10 0 a r� U '"',. NOTE:�TRIBUTARY ON MULTIPLE SPANS IS • EQUANTER SPAN TO CENTER SPAN NP - NOT PERMITTED - SITE SPECIFIC ENGINEERING REQUIRED EL a - o ZE c;0 o •o c • 0 0 c m . n o IV O " O ■ Z 03 o �l J R Zi Z W � J qf' WZrp O 0 m K z 0 FAN BEAM - LL a m 00 u)Vlio Q ? W m * - W r b FAN BEAM (19'-0" MAX SPAN) w���. > a W " J FAN BEAM FAN BEAM o g f Q HEADER comm ' z CEILING FAN AND/ T=.075" - 21l2• 212' 2 11 ►= OR LIGHT FIXTURE TYP. - X ( MAX. 30 lbs. ) Lu ��z> 'W, FAN BEAM #14 x 3 1/2" S.D.S. SCREW AT BEAM #12 S.D.S. SCREW AT HANGER CHANNEL � � s � ALUM. ALLOY 6063-T6 ATTACHMENT AT HEADER ATTACHMENT AT HANGER CHANNEL ogwm - • � v g o W '0 W : W IL Q = N , ' CLEAR SPAN (FT.) O.H. 6 7 8 9 10 11 12 13 14 '15 16 17 18 19 20 21 0 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 1' 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 2' S 6 6 7 7 8 8 9 9 10 10 11 11 12 12 NP 3� _ 7 7 8 8 9 9 10 10 11 11 12 12 NP NP NP q• _ _ _ 9 9 10 10 11 11 12 12 NP NP NP NP NP 5• _ _ _ _ _ 11 11 12 12 NP NP NP NP NP NP NP , r O, 4AS I. F . CAMPBELL ';0 Exp: IZ . m ., CIVIL y ii(p 1844- THows [PAY CKVIPSELL BEAM TYPES C�ATTACHED & FREESTANDING-L-ATT-IC-E-COVERS=10-PSF t1VE L-OAD-- 110, 120; 130-MP-H_EXP___B_8 CJ 3" SQ.x0.032' AL•UK BEAM DBL. 2"x6.5"x0.032" E W/ 12 GA. STL. "U" CHANNEL I OR -K w T=12 GA ASTM A653 SS 3.0, GRADE So GsoTrP, oar ALUM �---3.0--- I 3" SQ.x0.032" ALUM. BEAM " E W/ 12 GA. STL. U" CHANNEL ASTM A653 SS GRADE so G60 0.032' 6S' 0.04r 4.0' 20- MAX " 2.0� DBL. 2"X6.5 X0.032" I ALUM. ALLOY 3004 H36 OR EQUAL DBL. 2"x6 042" ., ALUM. ALLOY 3004-H36 OR EQUAL 0.042L_ 8.0' 3"W 0.042" BEAM K ALUM. ALLOY 3004-H36 OR EQUAL w Z Z W N v - Q a °,° z o - w 2 M- we 6 v a U z 0 W o ^= LI. O r"' �.. ' _"1 J VJ. SPACINGMAX ON SLAB (2). ) c_ m 3 ATTACHED FREESTANDING ATTACHED FREESTANDSNG W MAX.POST FTG. SPACING (IN.) (SPAN) (1) MIN. POST TYPE MAX.POST FTG. SPACING (IN.) (SPAN) 1 () MIN. MAX.POST MAX.POST POST SPACING SPACING TYPE 278.5'x0.032' FOR DBL FBEAM OR 8' FTG, (IN.) 1 () MIN. MAX.POST MAXPOST F7G• POST SPACING SPACING (IN) OR 3W TYPEz 2'x6-5'x0.032"DeLFBEAM (�) MIN. POSE. TYPE 13'-7" 5 16'-9" 15 16'-9" 17 14'-T 29 14'-7" -::r31 G 14'-Ir-- 15'4" H 14'-10" 15'-4" B 15 14'-1 " 15'-4" 28 17 14'-6" 15-1' 30 G , 5 11'-4" 6' 15'-3" 16 15'-3" 18 B 13'-3" 28 13'-3' 30 G 13'-7" 14'-1" H 13'-7" 14'-1" B 15 13'-7" 14'-1" 28 17 13'-3" 13=9' 29 G 6� 9,_9„ �, 14'-2" 16 14'-2" 18 B 12'-4" 28 12'-4' 30 G 12'-7" 13'-1" 12'-7" 13'-1" B 15 12'-7" 13'-1" 28 17 12'-3" 12'-9" 29 G 7, , " 8-6 8 13'-3' 16 13'-3" 19 B 11'-7" 29 11'-7" 29 11'-9" 12'-3" G 11'-9" 12'-3" B 16 11'-9" 12'-3' 28 18 11'-0' 12•4• 28 G 8' 7'-7- 9' 12'-7" 17 12'-T 19 C 11'-0" 29 11'-0' 29 11'-2" 11'-7" G 11'-2" 11'-T B 16 11'-2" 11'-T 29 18 10'-10 11 28 G 9 6-10" 10' 12'-0" 17 12'-0" 19 C 10'-4" 30 10'-4" 30 10'-7' 11'-0" G 10'-7" 11'-0" B 16 10'-7" 11'-0' 29 19 10'-3" 10'-8" 29 G 10' V' 2" 11, 11' 41 �" 1 ZO C 9'-1 9'-10" 330 H 10'-110,-1" 10'-610,-6" B 119 10'-19'-10 10'-6- Q,� p•_1" 229 G 11' T=12 OR 0 LL a r o� S'-8' 12' 10,-10" 18 0'-10" 20 C 9'-6" 30 9'-6" 30 9'-8" 9'-8" H 9'-8" 9'-8" C 17 91-8" 9'-8' 29 19 9'-6" 9'-2" 29 G 12' 14 GA 7.875 ASTM A o 8 0 0.04r 3_0' �3.o--I MAX A653 SS GRADE 50 G60 0.625' z.67s 3"x8'x0.042" BEAM W/ 14 GA. STL. INSERT M ASTM A653 GRADE 50 G60 - o 0 ,,, 3 N o _ _ cv - 1 MAX COL. SPACING ON SLAB (2).(3) a F O f° ATTACHED FREESTAND/NG x#sATTACHED : ���4�:� � i FREESTANDING _ ~ ~ m MAX.POST FTG. SPACING (IN.) (SPAN) (1) MIN. POST TYPE MAXPOST FTG. MIN. MAX.POST �LMK POST SPACING SPACING SPACING (IN.) POST FOR DBL FOR 37c8' (SPAN) (1) TYPE rx6,Sx0.03r `°BEAM a� '(�Ni)} r(1-) MI MAX.POST MAX.POST FTG. SPACING SPACING POST', FOR DBL FOR 3743- (IN') -T•YPE 2'x6.Sxo=r BEAM (1) MIN. POST TYPE o w'° Z o w z a U 0-;! tail k Q Q g LL 13'-7" 5' 16'-9" 16 16'-4" 18 B 14'-T 31 H 14'-1 15'-4" 14'-7" 33 J 14'-8" 15'-2" B 15 14'-1 ' 15'-4' 30 18 14'-1" 14'-T 31 G 5 11'-4" 6' 15'-3" 16 15'-0' 19 B 13'-3" 30 H 13'-7" 14'-1" 13'-3" 32 I 13'-4" T-10 B 16 13'-7" 14'-1" 29 18 T-10" 13'-4' 31 G 6' 9l-9" �t 14'-2" 17 3'-10" 19 B 12'-4" 29 G 12'-7" 13'-1l , 12'x" 31 I 12'-4" 1210 Jt6 "� 12'-7" 13'-1" 29 �e1.9 12'-0" 12'-4" 30 G �;- 8•-6" 8, 13'-3" 17 13'-0" 20 B 11'-T 29 G 11'-9" 12'-3" 11'-7" 31 H 11'-8" 12'-1" B 17 11'-9" 12'-3" 28 19 11'-2" 11•-T 30 G 8, DBL. 3"x8"x0.042" BEAM L ALUM. ALLOY 3004-H36 OR EQUAL 3"x8"x0.042" BEAM W/ 12 GA. STL. INSERT N ASTM A653 GRADE 50 G60 NOTE WHERE 12 AND 14 GA STEEL INSERTS OCCUR AS SHOWN IN THE SPAN TABLES. THEY SHALL BE INSTALLED THE FULL LENGTH OF THE XW BEAM. J J LL ^ 0 r' 7._7" 9' 12'-7" 18 12'-3" 20 C 11'-0" 29 G 11'-2' 11'-7" 11'-0" 30 H 11'-0" 11'-4" B 17 11'-2" 11'-T 29 20 10'-7" 11'-0" 29 G 9. E N If m � cai m c.04 a z � ;, < N Q- - WF�„, } z U. W m a -- o 2 z U 7 a &ry O - a N a o to m w t� w w m z m 3: ai i a 3, 0 e to CC v � W O O W 4 w Q 6'-10" 10' 12'-0" 18 11'-8" 21 ^ c; 10'-4" 30 G 10'-7" 11'-0" 10'-4" 30 H 10'-0" 1 p'-9" 17 10'-7" 11' 0" 29 2p 10''1" 1 D' 4" 29 n V 1 O' FOOTNOTE: 'SAMPLE" FIGURE INDICATES EXPOSURE 6 FIGURE INDICATES EXPOSURE C WHERE ONLY ONE FIGURE SHOWN INDICATES EXP. B & C. FOOTNOTES TO ALL SPAN TABLES: 1. FOOTING SHOWN REPRESENTS LENGTH OF EACH SIDE AND DEPTH OF CUBED FOOTING WITHOUT SLAB. WHERE SLAB OCCURS, CUBED FOOTING SIZE MAY BE REDUCED 6" EACH SIDE FOR FREESTANDING ONLY. _ _ _ _ _ _ _ _ _ _ 2. THE'MAXIMUM COLUMN SPACING ON EXISTING SLAB _ _ SHALL BE THE SMALLER OF THE MAXIMUM SPACING SHOWN IN THIS COLUMN OR THE MAXIMUM POST SPACING SHOWN FOR THE SELECTED BEAM. 3. THE SLAB SHALL BE A MINIMUM IV-O'WIDE BY THE MAXIMUM COLUMN SPACING MEASURED AT THE COLUMN AND SHALL NOT CONTAIN ANY CRACKING FOR 25 8 30 psf. THE DISTANCE FROM COLUMN TO SLAB EDGE SHALL BE 9114' MINIMUM. SEE ALTERNATE FOOTING TABLES SHT. 9 FOR ATTACHED COVERS T=12 OR nsTrn FAM SS so G60 8.0 oar TYP. I. ..,,�. 3 0' _..._......�... _ - MAX DBL. 3"X8"X0.042" BEAM W/ DBL. 14 GA. STL. INSERT O ASTM A653 GRADE 50 G60 DBL. 3"X8"X0.042" BEAM W/ DBL. 12 GA. STL. INSERT P ASTM -653 GRADE 50 G60 NOTE WHERE 12 AND 14 GA STEEL INSERTS OCCUR AS SHOWN IN THE SPAN TABLES, THEY SHALL BE INSTALLED THE FULL LENGTH OF THE rx8' BEAM. 6'-2" 11. 11' 11'-2" 121 C 9'-1 9'-10" 33p �_•r 10'-1; 0.-0" 10'-6; 0.-3" B 120 10 -1 "9'-7" 10'-6 9.-0" 229 G 11' 5-8" 12' 0'-10" 18 10'-8" 21 C 91-6" 30 9'-8" 91-8" 9'-6" 31 H 9'-7" 9'-4" C 18 9'-8" 91-8" 29 21 9'-2" 8'-9" 30 G 12 _ M ' ', J J (n ' t ,r MAX.COL. SPACING ON SLAB 2 (). (3) O !2R tr F ATTACHED FREESTAND/NG ATTACHED FREESTANDING } ~ ~_ m O M MAX.POST FTG. SPACING (IN.) (SPAN) (1) MIN. POST TYPE MAX.POST ,FTG. MIN. MAX.POST MAX.POST SPACING (IN.) POST SPACING SPACING (SPAN) 1) TYPE FOR DBL FOR 378' ( 27t65'x0A3r BEAM FTG, (IN.) 1 () MIN. MAX.POST MAX POST FTG, POST SPACING SPACING (IN) TYPE FOR DBL FOR 3743' 1 2'x6.57c0.03r BEAM () MIN. POST TYPE j 3'_7" 5' 16'-9" 17 15'-0" 19 B 14'-T 32 I 14'-1 15'-4' 14'-7" 34 J 14'-4" 14'-10 B 16 14'-1 15'-2" 31 19 13'-8" 14'-2" 33 G H , 5 �a� s.. 15'-3" 18 13'-9" 20 B 13'-3" 31 I 13'-7' 14'-1' _ 13'-3" 34' J 13'- I" 13'-T B. 17 13'-7' 13'-1 " 31 - - 19 12'-6" 13'-0" 32 G . 6.. ..z`___ w 91-9" , 7 14'-2" 18 12'-9" 20 B 12'-4" 31 H 12'-7' 13'-1" 12'-4" 3i `) 12'-2" 12'-7" B 17 12'-7" 12'-1 30 20 11'-7" 12'-1" 31 G , 7 8 -6 " 8 13'_3" 18 11'-10 20 B 11'-T 30 H 11'-9" 12'-3" 11'-7" 32 J 11'-4" 11'-9" B 18 11'-9' 12'-1" 29 20 10'-10" 11'-3' 31 G 8• -7 " 7-7" 9 12'-7" 19 11'-3" 21 B 11'-0" 30 H 11'-2" 11'-T 11'-0" 32 i 10'-9" 11'-Z" B 18 11'-2' 11'-4" 29 21 1 p'-3" 1p'-8" 3o G , 9 V-10" 10' 12'--0 19 10''8" 21 C B 10--4. 30 H 10'-7' 11'LL -0' 10'-0' 32 G 10'-Z" 10'-7" B 18 10'-7" 10'-9" 29 21 9'-9" 9'-10" 30 G 10 6'-2" 11 • 11' 19 10'-2" 22 `� 9'-10" 30 H 10'-1' 10'-6' 9'-10" 32 1 9'-9' 9'-10" B 19 10'-1' 10'-3" 29 21 9'-3" 9'_p" 31 r G 1 1 , " 5 -8 12 0'-1 20 9'-9' 22 9'-6" C 31 H 9'-8" 9'-8' 9'-6" 33 J 9'-4" 9'-1" C 19 9'-8' 9'-4" 29 22 9'-0" W-3" 31 G 12' ThlnkPadlDuralumWMO 0 1 95152 1-1 4 SubmhMU-28-14 D 44", 826201 4 6 34 25 AM, CYLBPDF Wtftor, No. C37948 EX.P. 03/31/% I10MAS I,CAMPBELL " T Exp: C CIVIL • ��. Tt-iCMAS FRAY Ckippat 7 L ThlnkPad\DuralumVAPMO 01952-21-14 Submh= I ATTACHED & FREESTANDING LATTICE COVERS - 10 PSF LIVE LOAD - 110, 120.130 MPH - EXP. B & C DBL. 2"x6.5"x0.042" L DBL. 3"x8"x0.042" BEAM 3"x8"x0.042" BEAM W/ 14 GA. STL. INSERT 3"x8"x0.042" BEAM W/ 12 GA. STL. INSERT W/ DBL. 3"x8"x0.042" BEAM DBL. 14 GA. STL. INSERT o a J �� N O W z ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTAND/NG W q SMAX.COL. SPACING o MAXPOST FTG- MIN. MAX.POST FTG. MIN. MAX.POST FTG. MIN. MAX.POST FTG. MIN. MAXPOST FTG. MIN. MAX -POST FIG. MIN. MAXPOST FTG. MIN. MAXPOST FTG. MIN. MAx.POST FTG. MIN. MAXJKW FTG. MIN. j p aq o � Q ON SLAB ¢ - SPACING (IN.) POST SPACING (IN.) POST SPACING (IN.) POST SPACING (IN.) POST SPACING (IN.) POST SPACING (IN.) POST SPACING (IN.) POST SPACING (IN.) POST SPACING (IN.) POST SPACING (IN.) POST m ¢ o (SPAN) (1) TYPE (SPAN) (1) TYPE (SPAN) (1) TYPE (SPAN) (1) TYPE (SPAN) (1) TYPE (SPAN) (1) TYPE (SPAN) (1) TYPE (SPAN) (1) TYPE (SPAN) (1) TYPE (SPAN) (1) TYPE It (2) (g) f- OU ¢ ¢ 13'-T' 5' 18'-0" 15 B 18'-0" 29 G 21'-8" 16 B 21'-8" 31 G 20'-9' 16 B 20'-9' 31 G 22'-8" 17 B 22'-8" 31 G 29-2" 18 29'-2" 33 H a s o Q 18'-0 18 17'-6 31 21'-8" 19 21'-2" 33 H 20'-9" 18 20'-2" 33 H 22' 8" 19 22'-1" 33 H 29'-2" 21 C 28' 6' 36 I 5, o 11'-4" 6' 16'�16'� 168 B G 19'-9 119 C 19'-9 9 332 G 19'-0 119 B 19'-0 332 G 20' 120 C 20' 332 G 26' 121 E 26' 335 H 9,-9 _3" 9'-0" 8'-6" 20'-8" 20'-2" 26'-8" 2s'-0" 1 6' am W 9._9" 7. 15'-2"5 169 B 4�229 G 18' 120 C 18' 4"7'-10 331 �j 17'- 1T-7" 1 19 C 17, 17'-1' 331 G 19'- �9.-2" 120 C19'- �9.-2"332 24' 122 E 24' 334 2 18'x" Cj 24'-8" 24_1. H 7' g a Z 8'-6"8' 14'-314'-0 1 B G 1T -2"T-2 120 C 17'- 16•-9 331 G 16'-0 120 c 16'-6 6_1" 331 G 18'-0"8'-0 121 Ci 18'-0 331 (j 23'- 23'-2 2� E 23'- 333 8' 19 6'-6" 8'-0" - H J 7._7" 9' 13'-013'-6 1 Ci 13'Z' 330 G 16'- 1 E 16'- � 331 G 15'-6 120 G. 15'-0 5�_2" 331 G 17'-0"7 121 E 17'-0 331 1, 223 1. 9� LL 19 3.-1 6.-3" 21 5•-9" 5'-6" -0" 7'-0" G 21 =10 E 21'-3" 34 H 6'-10" 10' 12'-912'-9 120 �, 12'-9;2.-6 33p G 15' 1 E 15'-4 5,-1" 332 G 14-94-9" 121 E 14'-94'-4" 332 G 16'-116.-1" 121 E 16'-1i6.-1" 332 G 01 -91 223 E 0. 15'-4" 21 20'-9" 20' 2" 34 H 10' 6'-2" 11. 12'-212'-2 120 C 12-11'-10" 330 G 14'x"4'-8" 121 E 14'-8"4'-4" 332 G 14'-14'-1" 121 E 14'-;3--8 332 G 15' 122 E 15' 332 G 19'-9"9'-9" 224 E 19'-99'-3" 334 I 11' Q 15'-4" 15'x" IL r 5'-8" 12' 11'-0" 18 C 11'-8" 31 G 14'-1" 19 E 14'-1" 32 �. 13'-6" 19 E 13'-6" 32 G 14'-9" 19 E 14'-9" 32 19'-0" 21 19'-0' 35 y 11'-8 20 11'-4 31 14'-1" 22 13'-9" 32 13'-6" 21 13'-2" 32 14'-9" 22 14'-9" 33 H 19'-0" 24 E 18'-0" 35 12' ' r .o o� o' J Z } ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTAND/NGS =MAXCOL. SPACING _ MAX•POST FTG. MIN. MAXPOST FTG. MIN. MAX.POST FTG. MIN, MAX.POST FTG. !, N, MAXPOST FTG. MIN. MAXPOST FTG. MIN. MAXPOST FTG. MIN. MAXPOST FTG. Mlry, MAX.POST FTG. MIN. MAX POST FTG. MIN. ONS m SPACING (IN.) POST SPACING (IN.) POST SPACING (IN.) POST SPACING (IN.) POST SPACING (IN.) POST SPACING (IN.) POST SPACING (IN.) POST SPACING (IN.) POST SPACING (IN.) POST SPACING (IN.) POST M � (2).(3) (SPAN) (1) TYPE (SPAN) (1) TYPE (SPAN) (1) TYPE (SPAN) (1) TYPE (SPAN) (1) TYPE (SPAN) (1) TYPE (SPAN) (1) TYPE (SPAN) (1) TYPE (SPAN) (1) TYPE (SPAN) (1) TYPE F' 13'-T' 5' 18'-0' 16 B 18'-0" 31 G 21'-8" 17 B 21'-8" 33 H 20'-9" 17 B 20'-9' 32 G 22'-8" 18 B 22'-8" 33 H 29'-2" 19 C 29'-2' 35 1 5, Q 1 T-0" 19 17'-0' 31 H 21'-4" 20 20'-7" 34 20'-4" 20 19'-8" 34 H 22'x" 20 C 21'-0" 35 I 28'-9" 22 2T-8" 37 K N 11'-4" 6 16'-4" 17 B 16'-4" 30 G 19'-9" 18 C' 19'-9" 32 G 19'-0" 18 B 19'-0" 32 G 20'-8" 18 C 20' 8" 32 G 26'-8" 20 E 26' 8" 35 I r 16'-2" 19 15'- 30 19'-7" 21 18'-9" 34 I� [ ! 18'-8" 20 C 18'-0" 33 H 20'-4" 21 19'-8" 34 H 26'-3" 23 25'-3" 36 K 6� o x a y 9'_9" 7' 15'-2" 17 B 15'-2" 30 G 18'-4" 18 C 18'-4" 31 G -.17* -7" 18 C 17'-T 31 G 19'-2" 19 C' 19'-2" 32 G 24'-8' 20 E 24'-8" 34 H ¢ w a a 15'-0" 20 14'-4" 30 18'-1" 21 17'x" 33 , " H 1 T-3" 21 16'-8" 33 18'-10 21 18'-2" 33 H 24'-4" 23 23'-6" 36 I 7' N LL m 8'-6" 8' 14'-14.-1 120 B 14'-13 229 G 17'- 122 C 17' 332+ G 16'-6 6.2" 121 C 16'-05.7" 332 G 18'-0 7'-8" 122 C 18' 333 G 23' 224 23':?:. --'-0 335 H _J C -6" 17'-0 6'-3 7'-1" H 22'-9 E 1 8' J 7'-7" 9' 13'-0" 18 C 13'-0" 30 G 16'-3" 19 E 16'-3" 31 15'-0" 19 C 15'-6" 31 G 17'-0" 19 E 17'-0" 32 1'-1 21 1'-1 3a H 9' LL 13'-3" 21 12'-9 30 16'-0" 22 15'-4" 32 _ 15'-3" 22 14'-8" 32 16' 8" 22 16'-1" 32 G 21'-0" 24 E 20'-8" 34 I 6'-10" 10' 12'-9" 18 C 12'-9" 30 G 15'-4" 19 E 15'-4" 32 14'-9" 19 E 14'-9" 31 G 16'-1" 20 E 16'-1" 32 0'-9' 21 0; 9' 34 12'-7" 21 1IT-1 30 15'-2" 22 14'-7" 31 C 14'-6" 22 14'-0" 31 15'-10 23 15'-3" 32 G 20'-4" 25 E 19'-8" 34 �"� 10 }IQ 6'-2" 11' 12'-212-0" 121 C 12'-;1,-7' 33p G 14'-8"4'-6" 223 E 14' 8"4'-0" 332 G 14 123 E 14'-;3.�" 331 G 15' -0 E 15'-4'4._7" 332 G 19'-9 225 E 19-9 8--9, 334 66 Q 13.-10" 15'-2" 1-7 H 9'-6" I 11' r 5'$" 12' 11'-0"1��" 122 C 11-011•-1 331 G 14'-13,-10 223 E 14'-113.x" J32 G 13'-63.-3" 223 E 13'-6 2.-9" 332 G 14'-9 4�-6" 223 E 14'-9 332 H 19'-0 226 E 19'-0 8,-0" 3 UJ H 4'-0" 8'-8" 12' h yo ATTACHED FREESTANDING ATTACHED FREESTAND!!S? ATTACHED FREESTAND/NG ATTACHED FREESTAND/NG ATTACHED FREESTAND/NG } > a w o MAX.COL. SPACING � o MAX.POST FTG. MIN. MAXPOST FTG. MIN. MAx.P057 FTG. MIN. MAx.POST FTG. MIN. MAX.POST FTG. MIN. MAX POST FTG. MIN. MAX.POST FTG. MIN. MAXPOST FTG. MIN. MAXPOST FTG. MIN. MAX.POST FTG. MIN. ¢� F- Unary J J N �1 ■ ■ OHS m SPACING (IN.) POST SPACING (IN.) POST TYPE SPACING (IN.) POST TYPE SPACING (IN.) POST SPACING (IN.) POST SPACING (IN.) POST SPACING (IN.) POST SPACING (IN.) POST SPACING ( IN.) POST SPACING (IN. POST ) O m 3 O H oC m (2), (g) F SPAN (SPAN) (1) TYPE (SPAN) ( (1) (SPAN) (1) (SPAN) (1) TYPE (SPAN) (1) TYPE (SPAN) ) (1) TYPE (SPAN) (1) TYPE (SPAN) (1) TYPE (SPAN) (1) TYPE (SPAN) (1) TYPE � m a o m 13'-7" 5' 18'-0" 17 B 17'-8" 33 G 21'-8' 19 B 21'-4" 34 H 20'-9" 18 B 20'-4" 32 H 22'-8" 19 B 22'4" 35 1 29'-2' 20 C 28'-9" 37 , Q 1T-3 20 16'-6 34 H 20'-10 21 20'-0" 36 K 20'-0" 21 19'-1" 34 I 1'-10" 21 C 20'-10 36 K 28'-2" 23 E 6'-10 39 K 5 r 11 •-4" 6, 16'-4" 18 B 16'-2" 32 G 19'-9" 19 C 19'-7" 33 H 19'-0" 19 B 18'-8" 32 H 20'-8' 19 C 20'-4" 34 H 26'-8' 21 26'-3" 36 15'-10' 20 15'-1 33 H 19'-1" 22 18'-3" 35 i 18'-3" 21 C 1T 6" 33 I 20'-0" 22 19'-1" 36 I 25'-9" 24 E 24'-7" 38 K 6 W o W 9'-9" 7' 15'=2' 18" B-` 13'-0" - � 3J_A18'x" 20 C 18'-1' � 33 H 17'-7" 19 C 17'-3" 31 G 19'-2" 20 C 18'-1 33 H 24'-8' 22 24' 4" 35 I ,,. _. m = m 14'-8 21 14'-0" H 17'-8" 22 16'-10 34 17'-0" 22 16'-2" 33 H 18'-6" 23 17'-8" 35 I 23'-10 25 E 22'-9" 37 K 7 z,;; WW N8�" 8' 14'-3" 19 B 14'-1" 3 20 C 17'-0" 32 G 16'-6" 20 C 16'-2" 30 G 18'-0" 20 C 17'-8" 33 G 22'-9" 35 1 J � <62 0o'n7'-7" 13'-9" 21 C 13'-1' 16'-7 23 15'-10 34 H 15'-10" 22 15'-2" 32 H 17'-4" 23 16'-7" 34 H 25 E 21'-3 37 K 8 9' 13-6 19 C 13'-3" 3G 16'-3' 21 E 16'-0" 32 G 15'-6" 20 C 15'-3" 31 G 17'-0" 21 E 16'-8" 3 G V3'222 23 1'-6" 34 H 13'-0 22 12'� 32 15'-8" 23 15'-0" 33 i 15'-0" 23 14'-3" 32 H 16'-4" 24 15'-T 34 H 26 E 20'-1" 36 K 9' y a 6'-10" 10' 12'-9' 20 C 12'-T G 15'4' 21 E 15'-2" 32 G� 14'-9" 21 E 14'-6" 31 G 16'-1" 21 E 15'-1 3 23 0'-4' 34 H p12'-3 22 11'-9 14'-10 24 14'-2" 33 H 14 -2" 23 13 -7" 31 15'-7" 24 14'-10 ' 33 20-0 26 E 19'-1" 36 I 10, W 6'-2" 11. 12'-211•-9 223 C 12'-0; I G 14'x'4,-2" 224 E 14' 6"3.-7" 332 H 14-13'-7" 224 E 3'-1 331 G 15' 4.-10" E 15'-14�-2" 19'-9"9'-1" 333 227 E 19'-0 .8 35 335 cn Q -3" G 3'-0" 24 H 11' nLu VM 5'$" 12• 11'-811'-3 223 Ci 11'-610.-9 G 14'-113,-7" 22 E 13'-113 332 H 13'-6 224 E 13'-; Z' 332 H 1f-:29'�-2" 225 E 14'-013'-T 332 H 19'-0'8'-3" 227 E 18'-8 ;•� 335 a N 24 _0" 3'-0" -p" G 12' I