Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
10874 (SFD)
Building Owner 53--124 Carra.*iza t Management P.O. BOX 1504 78-105 CALLE ESTADO LA QUINTA, CALIFORNIA 92253 Mailing �� Address P. 0. Basi City Zip Tel. La Quinta . -92253 564-i 48fi Contractor Sane City State Lic. City & Classif. 524325 Lic. # 1235 Arch., Engr., Designer Address Tel. City Zip State Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under Provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and.Professions*Code, Y nd m license is in full force and effect. SIGNATURE \ DATE OWNER -BUILDER DECLARATION ' I hereby affirm that I am exempt from the Contractor's License -Law for the following reason: (Sec. 7031.5,Susiness and Professions Code: Any city or county which requires a permit to construct, atter, improve, demolish, or repair any structure,. prior to its issuance also requires the applicant for such permit to rile a signed statement that he is licensed pursuant to the provisions or the Contractor's license "Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions 'Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than rive hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation; will 'do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner or property who builds or improves thereon and who does such work himself or through his own employees, provided that' such Improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of safe.) O I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law, does not apply to an owner or property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) - 0 1 am exempt under Sec. B. 8 P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that 1 have a certificate of consent to self -insure, or a certificate of Worker's.Compensation Insurance, or a.certified copy -thereof. (Sec. 3800,. Labor Code.) Policy No. Company Copy is filed with the city. .❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed it the permit is for one hundred dollars (S100) valuation or less.) 1 certify that in the performance of thg work for which this permit is issued, I -shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. fSec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-. mentioned property for inspection purposes. Signature of applicant Date P4 No. 10874 11LDING: TYPE CONST. ' OCC: GRP.; P. Number 774-051-0067 Description Lot 19 Block 228 t Descriptionfs�'t.�tt��a�rt;'�-.. Sq. Ft. 1537 No. No. Dw. Size Stories Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Parfait does not include block malls or 5timated Valuation 87 , 024.50 ' PERMIT AMOUNT PlanChk. Dep.'' 2550.00 Plan Chk. Bal. 249.37 Const. 585.50 Mech. 6T. 0 0 Electrical 125.90 Plumbing 135.00 S.M.I. 8.80 Grading 20.00 Driveway Enc. 20.00 Infrastructure 1958.05 c TOTAL 3414.62 3164.62 REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center. Line Rear Setback from.Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES 1ST FL. SQ. FT. ® $ UNITS COLL. AREA 2ND FL. SO. FT. YARD SPKLR SYSTEM POR. SQ. FT. ® MOBILEHOME SVC. BAR SINK GAR. SO. FT. ® POWER OUTLET ROOF DRAINS CAR P. SQ. FT. DRAINAGE PIPING WALL SQ. FT. @ DUCT WORK DRINKING FOUNTAIN. SQ FT ® URINAL ESTIMATED CONSTRUCTION VALUATION $ METER LOOP WATER PIPING NOTE: Not to be used as property tax valuation REINF. STEEL FLOOR DRAIN MECHANICAL FEES GAS (FINAL) WATER SOFTENER VENT SYSTEM FAN EVAP.000L HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED FINAL INSP. LAUNDRY TRAY AIR HANDLING UN4T CFM KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER. B.T.U. SQ. FT. ® c BATH TUB 617 SQ. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SQ. FT. RESID ® 11/4 c SEWAGE DISPOSAL -SPARK ARRESTOR SQ.FT.GAR @ 3/ac HOUSE SEWER INSULATIONISOUND 5- 2 ) FINISH GRADING GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE / PLUMBING ELECTRICAL HEATING & AIR GOND. SOLAR SETBACK GROUND PLUMBING 1W, RGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS ' SEWER OR SEPTIC TANK ROUGH WIRING DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING '(FINAL) OTHER APPJEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM ' WATER SYSTEM GRADING cu. yd. $ plus x$ =$ LUMBER GR. FINAL INSP.602 FRAMING / /i FINAL INSP. ROOFING !/1 Ge 617 REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE -SPARK ARRESTOR GAR. FIREWALL LA HI MESH INSULATIONISOUND 5- 2 ) FINISH GRADING FINAL INSPECTIO a3 CERT. OCC. FENCE FINAL DESERT SANDS UNIFIED SCHOOL DISTRICT 82-879 Highway 111 NOTICE: Indio, CA 92201 Document Cannot Be Duplicated (619) 347-8631 Date 4/27/92 No. 111346 Owner Name Type of Permit General Contract Management No. 53124 street Avenida Carranza city La Quinta zip 92253 La Quinta Permit # Log # . Study Area 111 APN # I Tract # Lot # Square Footage 1536 Type of Development I No. of unite 0 Single Family Residence Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school hu dlity fees imposed pursuant to Government Code 53080 in the amount of Fl. -58--1 X 11.536 or $ 2,426.88 have been paid to D.S.0 S.D. for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By General Contract Management Name on the check Telephone 564-1486 By James E. Lively Assistant Superintendent, Business Services 1 Fee collected /exem ted b p y Shelley D. Bennett .., . n ' Payment- Received; y^ Signature ` /�,(��, �J %��� r yCheck Mo. -14112 Collector. Attach a copy of county or city plan check application form to districtcopy,for all waivers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy -Accounting 0OACHELLA VALLEY MUTE DtSTAtCT CASH AECEIFr DETAIL Lots) Tract.`. G.A. code ❑ Backflow(s) O HouseLatemi(s) ❑ DetectorCheck(s) O Mote Surcharge Znitation Capacity Charge b KI ❑ WS.&F.C. O Temporary Construction Meter O Tum on Charge ❑ UncoNected Account - Name ❑ inspection Fee - Tract - r Fee - O Plan Check Fees Water I Sewer - Tract - ❑ Bond Payment - A.D. - Bond_ Asamt D Customer Deposit ❑ Other Remarks: � � V TOTAL 6 II r,,v4ju floceivedFrom• �•� Address: DSC S9' Account No. Vr7' n 1. Service Address A U t • � ri�,..ret ,rf ..► % t• 0OACHELLA VALLEY MUTE DtSTAtCT CASH AECEIFr DETAIL Lots) Tract.`. G.A. code ❑ Backflow(s) O HouseLatemi(s) ❑ DetectorCheck(s) O Mote Surcharge Znitation Capacity Charge b KI ❑ WS.&F.C. O Temporary Construction Meter O Tum on Charge ❑ UncoNected Account - Name ❑ inspection Fee - Tract - r Fee - O Plan Check Fees Water I Sewer - Tract - ❑ Bond Payment - A.D. - Bond_ Asamt D Customer Deposit ❑ Other Remarks: � � V TOTAL 6 II CALVIN C. KAMINSKAS Assistant Commissioner (714) 275-3000 DATE DEVELOPER'S NAME: ADDRESS: OFFICE OF AGRICULTURAL COMMISSIONER JAMES O. WALLACE, Commissioner 83-612 Avenue 45 Suite. 7 Indio, CA 92201 (619) 342-8291 DAN RILEY Sealer, Weights & Measures (714) 275-3030 y, 7 CASE NO. pf Z, �'�-- TELEPHONE: Dear Developer: IN After reviewing your landscaping plans, all plant material listed is not in violation of quarantine laws governing the Coachella Valley. If substitutions do occur and they differ from plant material listed, this office must be notified immediately. Thank you for protecting and preserving the Coachella Valley's pest -free environment. C r Ag, ultiiral Commissioners Office cc: Indio and Riverside 4880 LEMON STREET, ROOM 19, RIVERSIDE, CALIFORNIA 92501 — FAX (714) 275-3012 FINNELL COMPANY 7146593961 P.06 MANDATORY MEASURES CHECKLIST: RESIDENTIAL page 2 MF-1R ===—x=xsaascsxsssrlxsm=etaa..;assscma=amrx=�x�=xa=aaxxa.rzsczx:sx_--=� :a,rasemsax=xx,,;xxaaz: =x=x^ Project Title.......... GEN CONTR MGMT 1058 Oatg.,...... 04/20/92 =x=�=z.csru�xYxxusxxxex.x xssaaamcaaas�=mz�ryxacaaawsrassaac7scxrsrc.:eaasczasxssx-==x�-x•:xx.=x=a^•:-,:� MICROPAS3 v3.11 File-GCM1058 Wth-CTZ15 Program -FORM MF -1R User#-�,MP1325 User -ENERGY CONSULTING GROUP Run --GEN CONTR MGMT 105B ..,...--- ---------..........-----------_.------------------------------- HVAC ----.. -------------_-_-w---- HVAC AND PLUMBING SYSTEM MEASURES ------_-..w. ---------------- --- Design- Enforce - or ment 2-5352(g) and 2-5303: Space conditioning equipment sizing: . at1.nr.h,.rmJ nu 1 flt 1 nm _ heating systems. * 2-5316(a): Ducts. constructed, installed and insulated per .Chapter 10, 1976 UMC. 2-5316(b): Exhaust systems have damper controls. .2-5314(c): Gas-fired space heating equipment has intermittent ignition devices. 2-5314: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. 2-6362(1): Water heater .insulation blanket (R-12 or greater ). for storage and backup tanks for solar Water heating systems (first 5 feet of pipes closest to tank insulated to R-3 or greater). 1 C31,36r,,IA&WI bItuTAlar,) ' i vtlli vuxaLxiia ►. iwt iiy. 2-5318(d):'Swimming Pool Heating 1. System has: a. On/off switch on heater. b. Weatherproof instruction plate on heater. c. Plumbed to allow for solar. 2. 75 percent thermal efficiency. 3 . Pool ' cover . 4. Time clock. 5. Directional water inlet, LIGHTING AND APPLIANCE MEASURES ------------------------------- Design- Enforce - or ment 2-5352(j ): Lighting -- 25 lumens/watt or greater for 9enoral lighting in kitchens and bathrooms. 2-5314(c): 'Gas .fired appliances equipped with intermittent ignition devices. 2-5314(a): Refrigerators, refrigerator -freezers, freezers and fluorescent lamp ballasts certified by the CEC. o::,�wJa:�..w��w.pros'F'a�e'--..�w.•.wr...w-•+*.r,.:....++.+»:..-.. ... ,...... �.�..,.._-._....,.-....�..w..�....�...,,...-...-...,..J .... ... _,..«...._..,_...—...........k,.�...+-..-.�:.,•+.�..........-..........cn... .+......-...r.. -..t . COMPUTER METHOD SUMMARY Page 3 C -2R S�C_IIII.^SII3L'i7I8>CIICY6 SS 7l,S LS 13 �l YS X�CaRR:..SS.».:L 0232 w3 II'�".S "3 t'�'L2'e3 Y�c'IIF3 A SS :>3SSF.—..IISIIII_IIII,".,, X�.IIIIII:. II.:IIII—_=II.�.-..�—.. Project Title.......... GEN CONTR MGMT 105E Date.,.;..... 04/20/92 asaxssxasa=xi=tttexaxexarzax�a.:,z"a�asxn�maxsxa�ac�aazs::r ��.:r..�asc���axzxzx-�aaa :a�IIaa��.^..^„a,r.ra���==�..... MICROPAS3 v3.11 File-GCM1058 Wth- CT215 Program -FORM C -2R User#-MP1325 User -ENERGY CONSULTING GROUP Run -GEN CONTR MGMT 1058 ; THERMAL MASS HVAC SYSTEMS Area Thick Heat Conduct- Surface Mass Type ( sf ) (in) Cap ivity R --value Location/Comments HOUSE .-------------------- HeatPump 7,6 HSPF= Attic 1 SlabOnGrade 169 3.5 28,0 0.98 R-0.0 ENTRY/KXTCHEN/BATHS 2 S1abOnGrade 1.367 3.5 28.0 0.98 R-2.0 REST OF HOUSE' - HVAC SYSTEMS WATER HEATING SYSTEMS Minimum Duct Duct Duct System Type Efficiency Location R -value Efficiency HOUSE (Btuh) Credits \ .-------------------- HeatPump 7,6 HSPF= Attic R-5 0,828 .AirCond i 1.0.50 SEER Attic R-5 0.818 WATER HEATING SYSTEMS SPECIAL. FEATURES/REMARKS ------------------------ Capa- R-12 or Pilot System # of city Greater Effic- Standby Input Size Type ---------- Heat (gal) ---- ----- Blanket iency Lose Rating -------- (Btuh) Credits Storage .-------------------- -------- ----- -- Electric 1 38 No .992 RE .92%. 4.5 kW n/a Recovery SPECIAL. FEATURES/REMARKS ------------------------ FINNELL COMPANY 7146593961 P.01 WATER HEATING Page I DHW 1^LS nL kY k4 AC tt l0i 7CC��==LSESC]Sf3CS, YY 7��Cr„14 S. F: LII 07l CS 15: L•1 tY 1LStGC.'1. i.ZA.C.SG•�CY YII.S IR 7S FC i3.-�=---C.^".�Y+."...."1..`..�__-^..•.^w��==�-.-. .,� Project Title.......... GEN CONTR MGMT 105E Date......... 04/20/92 Project Address........ .--------------------- LA OUXNTA Documentation Author... W J FINNELL ; Building Permit # Company ................ ENERGY CONSULTING GROUP telephone .............. 1,800-262•-9966 ; Plan Check / Date Compliance Method...... MICROPAS3 by Enesrcomp, Inc. ; Field Check/ Date ClimateZone........... 15 r-.---...,..-------------- MICROPAS3 v3.11 File-GCM1058 Wth-CTZ15 program -WATER HEATING User#-MP1325 User -ENERGY CONSULTING GROUP Run -GEN CONTR MGMT 1058 ---------- ------ ----------------------- 7------`-------w_----------------_----- WORKSHEET ONE: STORAGE GAS OR STORAGE ELECTRIC A. EQUIPMENT DATA 1. Water heater type....... 2. Manufacturer..........,, 3. Model number............ 4. Ignition device......... S. Tank volume. ........... 6. Recovery efficiency..... 7. standby loss............ 8. Rated Input ........:.... 9. Number of Heaters........ 10.Insulation Jacket....... Storage, Electric AMER APPLIANCE EFR40D n/a 38 gal .992 percent x 0.01' .0092 percent/hour x 0.01 15358.5 Btu/hr 1 No S. OPERATING DATA 1. Climate Cone. .. .... 2. Water heating budget...,. 3. Tank set temp........:.. 4. Water main temp......... 5. Daily hot water load._ 6. Ambient air temp........ 7. Adj. Standby Losses..... S. No. dwelling units...... 9. Pump power .............. 1O.Pumping energy.......... 15 18700 kBtu/yr/unit 140 F 70 F 50 gal 72.6 F .0092 1 0 Watts (0 Watts controller) 0 Watt-hr/yr (24 hr per day) C. WATER HEATING ENERGY CREDITS -------------------------------- 1. Credit Name ............. Recovery 2. Annual savings.......... 2805 kBtu/yr/unit D. ANNUAL WATER HEATING ENERGY 1. Recovery load........... 1.0539 kBtu/yr 2. Recovory enersy......... 7797 k8tu/yr 3. Standby loss energy..,., 1604 kBtu/yr 4. Pumping energy.......... 0 kBtu/yr source 5. Total energy............ 28203 k8tu/yr/unit source 6. Comparison .............. --9503 kBtu/yr/unit source 7. oints.... ............. Points, ''' r-12 8. Water Heating Energy Use 18.36 kBtu/yr/5f ( D5 x BE)) / 1536 sf FINNELL COMPANY 7146593961 P.03 HVAC.SIZING Page 1 HVAC AC Xi7=i .: =C ii xiR T. F.S L3 :.:CR..-•CiR Y.."..Y..."'...`-'..,"�,RCCZ R��:�Z�ZLZZSZT3 Z"1'�ZCL".X Z'1' iSL"SZ'19L L3 ZS Z`S�S'.=7@S"3 '3Z'L"'J"ZZ1:2 "3 R"..S' � Project Title.......... GEN CONTR MGMT 1056 Date........ 04/20/92 ProjectAddress........ _.. -----.------- LA QUINTA ,. Documentation Author... W J FINNELL :.Building Permit # Company.... ............. ENERGY CONSULTING GROUP Telephone .............. 1-800-262-9966 ; flan Check / Date Compliance Method...... MICROPAS3 by Enercomp, Inc. Field Check/ Date Climate Zone ........... 15 -------------------------- MICROPAS3 v3.11 File-GCM1058, Wth-CTZ15 Program -HVAC SIZING User#-MP1325 User -ENERGY CONSULTING GROUP Run -GEN CONTR. MGMT 1058 -------------------------------------------------------------------------------- GENERAL INFORMATION -------------------- Floor Area...... ......... Volume....... ............ Front orientation.......... Sizing Location............ Latitude ................... Winter Outside Design,..... Winter inside Design....... Summer Outside Design...... Summer inside Design..:.... Summer Range ............... Shading Used ............... Latent Load Fraction....... 1536 sf 13056 of Front Facing INDIO 33.7 degrees 29 F 70 F 112 F" 78 F 30 F No 0.20 270 deg ( W ) HEATING AND COOLING LOAD SUMMARY --------------------------- Heating Cooling Description (Btuh) (etuh) Opaque Conduction and Solar...... Glazing Conduction ............... GlazingSolar .................... Infiltration ..................... Internal Gain .................... Ducts............................ Sensible Load .................... Latent Load ...................... Total Load 9398 5151 3704 3072 n/a 6624 7699 4562 n/a 2550 2080 2.96 22881. 24155 n/a 4831 22881 .28986 Note: The loads shown are only one of the criteria affecting the selection of' HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., -must also be considered. It is the MVAC designer's responsibility to consider all factors when selecting the MVAC equipment. CEC Maximum output applicable for gas central furnaces only` . _.._,_, ...,..�.,�...: FINN ELL COMPANY.._ , —71465'939.6.1.- __ _ 'F:;. 04 CERTIFICATE OF COMPLIANCE: RESIDENTIAL. Page 1 CF-1R --�—�—'.�=2C13SC1='3���1��w'-1wm.�..w.+.wr.LS.:3'SQL"="3L"---=T:...-�.C.�..75:'IZr�—r.�3^3�+..... n.. -w .+. .�...: :��--����.-,.•. .. .�—�-- Project Title.......... GEN CONTR MGMT 1058 Date........ 04/20/92 Project Address..... ,.----------..-_-__-- LA QUINTA Documentation Author... W J FINNELL Company ................. ENERGY CONSULTING GROUP Telephone ............... 1-$00-262-9966 ' Building Permit # Plan Check / Date Compliance Method...... MICROPAS3 by Enercomp, Inc.. ; Field. Check/ Date. Climate Zone........... 15 ------..----,.-----___-- Ya(tata7aaaaa :aaaa�a7aa^at ss zta�aa�aazx :�.:;: as �=rz-css ^, �:arx :.r zsa�aaa�a aa;a,�a„ �aMaa.•.:.±��=.+,�p�� MICROPAS3 v3.11 File-GCM1058 Wth--CTz15 Program -FORM CF -1R User#-MP1325 Ueer-ENERGY CONSULTING GROUP Run -GEN CONTR MGMT 1058 GENERAL INFORMATION Conditioned Floor Area..... 1.536 sf Building Type .............. Single Family Detached Building Front Orientation. Front Facing 270 deg (W) Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.:.. Slab On Grade (Package D) Infiltration Control....... Standard BUILDING SHELL INSULATION Component Insul Type R --value Location/Comments Wall Rµ19 OUTSIDE, GARAGE ^_____ Roof R-38 ATTIC Door R-0 OUTSIDE, GARAGE S1abEdge R-0 OUTSIDE, GARAGE GLAZING Qlazine Area # of Interior Exterior Framing Orientation (sf) Panes Shading Shading Overhang Type Window Front (W) 20.0 -------------- 2 Drapes 50% bug scrn w^ y None - - Metal -- Window Left (N) 4.0 2 Drapes 50% bug scrn None Metal Window Back (E) 83.0 2 Drapes 50% bug 5crn None Metal;. Window Right ( 5 ) 32.0 2 Drapes 50% bug corn None Metal THERMAL MASS ------------ Area Thickness Hard Surfaced/ Type ------------ ------ (5f) --------- (in) Exposed -------------- Location/Comments I -- S1abOnGrade 169 -- 3.5 Yes --------- ,.-------- ENTRY/KITCHEN/BATHS S,lo OnGrado 1367 3.5 No REST OF HOUSE "-'^^"�'~^'�^^�--�-'•�^ •^_ ' -' F I N N E L L COMPANY-' �' ^ , --714E-5-93961 P. 0 g CERTIFICATE OF COMPLIANCE: RESIDENTIAL page 2 CF -1R ao�caaaagai¢aCaae a�c3caa:ewr=�::ca�=_�a�ia��Lx�:t::���ara ae _�ac�aaa.:3 nom.=,�.:a Gt Ct: =.a �.—i.e-.—.. ��77aaFi Project Title.......... GEN CONTR MGMT 1058 Date......... 04/20/92. M1uKUNAbj v:i. •1.1 F 11e-uumivbb wth-u i L'lb Program-wuKm ( ih iK User#-MP1325 User -ENERGY CONSULTING GROUP Run -GEN CONTR MGMT 105B -------------------------------------------------------------------------- ASSUMED HVAC SYSTEMS -------------------- Assumed Duct Duct As,sllmAd Syst om Ff f i n i Anny I gnat, i on R --WA I I IA HeatPump 7.6 HSPF Attic R-5 AirCond 10'.50 SEER Attic R-5 ACTUAL HVAC SYSTEMS Actual Output Manufacturer and Model # Actual System Efficiency ( Btuh ) ( or approved equal) Heating 7.60 DAY & NIGHT A042 Cooling 10.5 DAY & NIGHT Cooling Cox). i CCC Maximum output for Coo Central Furnace®+ Dtuh WATER HEATING SYSTEMS Tank R--12 or # Of Vol Greater ManllfaCturer and Model # Energy System Type Heat ( gal) Blanket:( or approved equal) Credits Storage, Electric 1 38 No AMER APPLIANCE EF'R40D Recovery SPECIAL FEA'rURES/REMARKS ------------------------ ..;..:::.:..,r�:��» '_ - ". F S N N E L L -- C O M P A N Y--^--�---...�!--- --:.. ,.,....:.T 1 4 6 5 9 3 5 6 1 �- - •.--•,--.•. • "CERTIF'ICATE OF COMPLIANCE: RESIDENTIAL. Page'3 CF -IR Projeot Title.........,.. GEN CONTR MGMT 105E Date...:..... 04/20/92 'minarcxxmx4etraexkxzxezL2�texzsa»»»lzztraarria»at�atrt�rrsssxa»ez�,:»»a« rcc»saa-. �=�==»�»,�,»».-»a=»»»»»»���.��� MICROPAS3 v3.11 File-GCM1058 Wth-CTZ15 Program -FORM CF -IR ; User!#-MP1325 User-ENERGY'CONSULTING GROUP Run -GEN CONTR MGMT 1056 ---_----..........-------------- ----,--___-...__..---------------.--_-....----..------_ COMPLIANCE STATEMENT -------------------- This certificate of compliance lists the building features and performance specifications needed to comply wit.h'Title 24, Chapter 2--53 and Title 20, Chapter 2, Subchapter Q, Article 1 of the California Administrative code. Thi6 oortifioatc hao boon signed by the individual with overall Jesiyo responsibility and the building owriar, who Tall i blain a copy of it and transmit the certificate to any subsequent purchaser of the building. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, all building conservation features which vary are indicated in the Special Features/Remarks-section. DESIGNER Name.... Company. ,Address. Phone... License. Signed ( date ) DOCUMENTATION AUTHOR Name .... W .I FINNEL.L. Company. ENERGY CONSULTING GROUP Address. 34F INDIAN HILLS MTN CENTER, CA 92361 PhQne1811 I-QQQ-242--9966 Si g ned (da e) OWNER Name.... Company. Address, Phone... Signed (date). ENFORCEMENT AGENCY Name.... Title... Agency.. Phone.., Signed (date);. FINNELL COMPANY 7146593961 P.07 MANDATORY'MEASURES,CHECKLIST: RESIDENTIAL Page 1. MF-1R .�.=i{.T.,�tC.��iCCA�LSt.t7i���======�G=======a�Lsas=a5ar2::aaaC'aa22': aCC:Yvarrtr.»mmnn^rn�^�•�•••••••••�:�.-- Project Title.......... GEN CONTR MGMT 1058 Date........ 04/20/92 Project Address........ - -------------^-------- LA QUINTA Dooumontation Author ... W J rINPX .L I Duil8ims Pormit 4 Company ................ ENERGY CONSULTING -_GROUP Telephone.............. i-800-262-9966 ; Plan Check / Date Compliance Method:..... MICROPAS3 by Enercomp, Inc. ; Field Check/ Date Climate Zone ........... 15 ----.------------- ____ =aa=aa====a=a�=a==aaa�a�,M=��„-,xs��a��,V:,:.»;1a..:W.�.::a=seas=aa=ate.=Sass=asamszTsatzrz ss ssbtrraaa=== MICROPAS3 v3.11 File-GCM1858 Wth-CTZIS Program -FORM MF -IR ; User#-MP1325 User -ENERGY CONSULTING GROUP Run -GEN CONTR MGMT 1056 ------------------------------------------------------------------- Lowrise 'residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whothor thea, ar© ahown olsewhave in the Jo,:urrion't6 ov urs thi6 witly. BUILDING ENVELOPE MEASURES Design- Enforce- er ment * 2-5352(a): Minimum ceiling insulation R-19 weighted average. 2-5352(b): hoose fill insulation manufacturers labeled R -Value . _ 2-5352(o)-* Minimum wall insulation in framed walls R-11 weighted average (does not apply to exterior mass walls). 2-5352(k): Slab edge insulation greater than 0.3%, water vapor greater than 2.0 perm/.inch. - water absorption rate no transmission rate no' 25311: Insulation specified or installed meets CEC quality standards. Indicate type and form. 2-5352(f): Vapor barriers mandatory in Climate Zones 14 and 16. 2.5317: Infiltration/Exriltration'Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Doors and windows certified. c. Doors and windows weathers.tripped; all joints and - penetrations caulked and sealed. 2-8352(e): Special infiltration barrier installed to comply with Sec. 2-5351 meets CEC quality standards. 2-5352(d): Installation of Fireplaces 1. Masonry and factory -built fireplaces have: a. Tight fitting, closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control. FINNELL COMPANY 7146593961 P.06 MANDATORY MEASURES CHECKLIST: RESIDENTIAL page 2 MF -IR project Title.......... GEN CONTR MGMT 1058 Date.',...',,. 04/20/92 =—==ssr=r=srxmtezrx=ttezes=======a�c,:taaxmcrsas=xaCkx===rix=sax=sncnascmrs�mszxaRcasW=zq====^____:==ss==ss= ' MICROPAS3 v3.11 File-GCM105B Wth-CTZ15 Program -FORM MF -1R ' User#-MP1325 User -ENERGY CONSULTING GROUP Run --GEN CONTR MGMT 1058 HVAC AND PLUMBING SYSTEM MEASURES --------------------------------- Design- Enforce- or- ment 2-5352(8) and 25303: Space conditioning equipment sizing: heating systems, * 2-5316(x): Ducts. constructed, installed and insulated per Chapter 10, 1976 UMC 2-531-6(b): Exhaust systems have damper controls. 2-5314(c): Gas-fired space heating equipment has intermittent ignition devices, 2-5314: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. 2-5352(1), Water heater insulation blanket (R-12 or greater) for storage and backup tanks for solar water heating systems (first 5 feet of pipes closest to tank insulated to R-3 or greater). \ 1 ���i��riBbGbi I b'Zu i' cai w i 1 i I i T � �N� i a�:� i vu.►ix�a iia �.,�Wl „y 2-5318(d): Swimming Pool Heating 1. System has: a. On/off switch on heater. b. Weatherproof instruction plate on heater. c. Plumbed to allow for solar.' 2. 75 percent thermal efficiency. 3. Pool. cover. 4. Time clock. 5. Directional water inlet, LIGHTING AND APPLIANCE MEASURES Design--Enforce- 2-5352(j): Lighting - 25 lumens/watt or greater for or ment senoral lighting in kitchens and bathrooms. 2-5314(c): Gas fired appliances equipped with intermittent ignition devices. 2-5314(a)= Refrigerators, refrigerator -freezers, freezers and fluorescent lamp ballasts certified by the CFC. 111 xffltj im IV'. iflx� �/ %;qVA,- . / A ��.�Il:i �f• III. Trtt A �k . paulim C t of 14a 1 This Certificate issued pursuant to the requirements of Section 306 of the Uniform Building! Code certifying that at the time of issuance this structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: BUILDING ADDRESS 53-124 Carranza Use Classification SFD Bldg. Permit No. 10874 Group R3 Type Construction VN f=ire Zone Use tone SR Owner of Building General Contract Mctmt. - Address P. O. Box 59 City La Ouinta. CA. 92253 By; . Lonnie Day Date. 6/23/92 Building Official POST IN A OONe?ICUOU! PLACE