Loading...
11-0456 (SOL)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 c&ht °f4Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/13/11 Application Number:' 11-00000456.: Owner: Property Address: 53710 AVENIDA CARRANZA LACROIX ROGER R J APN: 774-121-010-15 -000000- 53710 AVENIDA CARRANZA Application description: SOLAR LA QUINTA, CA 92253 Property Zoning: COVE RESIDENTIAL Application valuation: 17000 Contractor: Applicant: Architect or Engineer: HEGGE ELECTRICAL CON RS IN 83852 AVENUE 45 INDIO, CA 92201 v X011 (760) 775-4855 �jl�►1 �. Lic. No.: 748171 civ OF IJ�AUINYA ptNPI3GE 01W. ------------------------------------------------------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and Professionals C a my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License Class: CIO se No.: 748171 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is (; cenissued. ate: 4J ontractor:, I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number'are: I hereby affirm under penalty of pe rj y that I am exempt from the Contractor's State License Law for the Carrier DELOS INS CO Policy Number 02DKRM120083 08 'e following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to ' _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish; or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I should become subject to the workers' sation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 3700 of the Lab/RRKERS' 11 forthwith comp) those those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: Date: �licant: 1—) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: F LURE TO SECURCOMPENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CLTIES AND CIVIL FINES UPTO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her*own employees, provided that the DOLLARS ($100,000)• IN ADDI COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). ' Lender's Name: ' Lender's Address: LQPERMIT APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances d state laws relating to building construction, and hereby authori a representatives oI t ' count�yyto enter ui n the above-mentioned property for inspection purposes. Date / Signature (Applicant or Agent): Application Number . . . 11-00000456 Permit . . . ELEC-MISCELLANEOUS Additional desc . Permit Fee 22.50 Plan Check Fee 5.63 Issue Date . . . . Valuation . . . . 0 Expiration Date 11/09/11 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 7.5000 EA ELEC PWR APP >1 TO <=10 ---------------------------------------------- ----------------------------- 7.50 Permit . . . SOLAR PERMIT Additional desc . Permit Fee . . . . 22.50 Plan Check Fee 5.63 Issue Date Valuation . . . . 17000 Expiration Date 11/09/11 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA SOLAR COLLECTOR < 1000 4.50 1.00 3.0000 -EA SOLAR EQUIP MISCELLANEOUS 3.00 ------------------------7--------------------------------7------------------ Special Notes and Comments 2.5kW SOLAR ARRAY - (11) 230 WATT PANELS W/ (1) 3000W SMA INVERTER (195SF] 2010 CALIFORNIA ELECTRICAL CODE. May 10, 2011 2:55:46 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . .. . . . . BLDG STDS ADMIN (SB1473) 1.00 Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 45.00. .00 .00 45.00 Plan Check Total 11.26 .00 .00 11.26 Other Fee Total 1.00 .00 .00 1.00 Grand Total 57.26 .00 .00 57.26 LQPEENIIT t Z:3 53-710 AVENI +1•�� r y WJE W 9iST&�l L4 �! 'Ito 1lNCNIQk (m&A+t?•A Cow o Oiwlg:s� CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY AC DISCONNECT DA CARRANZA mitz - EXISTING SERVICE NEW PRODUCTION METER 0 0 6 w z w 0- C-) s; Ito -104.11 Ulo SINGLE LINE DIAGRAM 200 AMP MAIN SERVICE Bi -Directional Meter 314" C, 2 #10 THWN-2 +1 #10 GND to Aa l,�ejltiD +K b^% -*6 sNo Tkowt me "mw iub 1010 CMv-foA*4, b C.3a MAY 0 4 2011 FOM CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION OATE BY. Amimsoo4 cokw►Wr W MpT 6640A PV ARRAY 3l4" C, 2 #10 THWN-2 + 1 #10 GND EXTERNAL SMA EXTRE NAL AIC DISC. SUNNYBOY 3000 DIC DISC INVERTER (FU ED) (FUSED) 314" C, 2 #10 THWN-2 + 1 #10 GND 3/4"C, 2 #10 THWN-2 + 1 #10 GND' 12.500' CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION I DATE BY. 19.000' �- _-5.383' 3.283' WARNING ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED 690.5(C) - INVERTER WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE 690.64(B)(7) - PANELBOARD WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. RATED AC OUTPUT CURRENT NOMINAL OPERATING AC VOLTAGE 690.17/690.54 AC DISCONNECT WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. RATED Mpp CURRENT RATED Mpp VOLTAGE MAXIMUM SYSTEM VOLTAGE SHORT CIRCUIT CURRENT 690.17/690.53 - DC DISCONNECT WARNING THIS SERVICE IS SUPPLIED FROM MULITPLE SOURCES: UTILITY AND PHOTVOLTAIC 690.56(B)/705.10 - SERVICE CITY OF LA QUINTA BUILDING & SAFETY DEPT.. APPROVED FOR CONSTRUCTION DATE BY http://www.wholesalesolar.com/solar-panels.html A CHNT COMPANY asraonergy CHSM 6610P � $ D 4 1 Gla 2E A 3GelAray EEVA Bae s eet 210 0 Precision Solar Cell Manufacturing ----------------------------------------------- • First PV company in Mainland China to use Manufacturing Execution System (MES) in solar cell production. The products, processes, and equipments are strictly controlled using SPC tools for the highest quality and performance. U Aesthetic Appeal ----------------------------------------------- j ; • Modules are assembled with j] k= high quality, smooth aluminum x 1+ alloy frames. 215 220 225 230 I State -of -the -Art Solar Module Manufacturing ------------------------------------------------------- • Within the same power range and efficiency, cells are further sorted by the short circuit current in order to minimize losses caused by electric -mismatch. • IV and EL tests are performed before the lamination to ensure the consistency of encapsulated cells and process reliability. -The EL test is repeated on each module before shipping to ensure product's quality and reliability. afte C@US M 5%rollt, _hJ0RJU* P A © Chint Solar (Zhejiang ) Co.,Ud. All rights reserved. Specifications and designs included in this datasheet are subject to change without notice. C E mo -1 . Oho 201o/o4i-wr_c w `AST;zOnergy http://www.wholesalesolar.com/solar-panels.htmI A CHNT COMPANY Dimension Etectricat Characteristics Width 994mm / 3.261 feet Height 45mm / 0.148 feet Pmax(Wp) 210 215 220 225 230 156X 1 56(mm) Polycrystalline Silicon Isc(A) 7.80 7.96 8.12 8.27 8.43 60 pcs Frame VocM 36.53 36.65 36.77 36.88 37.00 Electrical Characteristics Imp(A) 7.09 7.23 7.38 7.55 1 7.69 Vmp(V) 29.60 29.65 29.70 29.76 29.81 Tolerance(Wp) ±3% 9 1000w/m' 8 7 800W/m' e 5 600W/m' 4 40oW/m' Max. System Voltage(V) DC1000V for SC II and DC600V for USA NEC NOCT 43.4°C Power Temp. Coeff(/°C) -0.46872% 3 2 Current Temp. Coeff(/°C) 0.05200 % Voltage Temp. Coeff(/•C) -0.34410% ' a 5 10 15 20 25 30 35 40 VoltageM Ambient Temp. (°C) -40-.85 Max. Mechanical Load(Kg/m') 240 IIIIIIIIIIIIIIIIII Test Condition Irradiance of 100 mW/cm', AM 1.5 Spectrum, and a Cell Temperature of 25•C Dimension Front View and Back View Length 1652mm / 5.420 feet Width 994mm / 3.261 feet Height 45mm / 0.148 feet Weight 20kg / 44.Olbs Cell Type 156X 1 56(mm) Polycrystalline Silicon Cell Matrix 6x10 Cell Number 60 pcs Frame t I O Chint Solar (Zhejiang ) Co.,Ltd. All rights reserved. Specifications and designs included in this datasheet are subject to change without notice. 0"'4vA 2010104-MXT-o'" I Front View and Back View Frame Cross -section - � '' I� - _ 111111111111111111 IIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIII �" IIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIII - �� � � - IIIIIIIIIIIIIIIIII _ - IIIIIIIIIIIIIIIIII a� IIIIIIIIIIIIIIIIII Ilfllllllllfllllll IIIIIIIIIIIIIIIIII I I O Chint Solar (Zhejiang ) Co.,Ltd. All rights reserved. Specifications and designs included in this datasheet are subject to change without notice. 0"'4vA 2010104-MXT-o'" I SUNNY BOY 3000 -US / 3800 -US / 4000 -US. SMA America, LLC Page 1 of 4 Home > Products > Grid -Tied Inverters > SUNNY BOY > SUNNY BOY 3000 -US / 3800 -US / 4000 -US SUNNY BOY 3000 -US / 3800. US / 4000 -US UL certified, reliable system managers The Sunny Boy 3000 -US, 3800 -US and 4000 -US inverters are specially . designed for countries that require UL certification. Automatic grid voltage detection* and an integrated DC disconnect switch simplifies installation, ensuring safety as well as saving time. These models feature galvanic isolation and can be used with all types of modules -crystalline as well as thin-film. The die-cast aluminum enclosure, with the OptiCool active temperature management system, guarantees the highest yields possible and a long service life, even under extreme conditions. The Sunny Boy 3800 -US is designed for projects with a current limit of 16A. * US Patent US7352549B I http://www.sma-america.com/en US/products/grid-tied-inverters/sunny-boy/sunny-boy-300... 5/3/2011 SUNNY BOY 3000 -US / 3800 -US / 4000 -US. SMA America, LLC Overview Technical data Downloads Input (DC) Max. recommended PV power (@ module STC) Max. DC power (@ cos co = 1) Max. DC voltage DC nominal voltage MPP voltage range Min. DC voltage / start voltage Max. input current / per string (at DC disconnect) Number of MPP trackers / fused strings per MPP tracker Output (AC) AC nominal power Max. AC apparent power Nominal AC voltage / adjustable AC voltage range AC grid frequency; range Max. output current Power factor (cos (p) Phase conductors / connection phases Harmonics Efficiency Max. effi ciency CEC effi ciency Protection devices Page 2 of 4 Sunny Boy 3000 -US Sunny Boy 3800 -US Sunny Boy 4000 -US 208 V AC 240 V AC 208 V AC 240 V AC 240 V AC 3750 W 4750 W 4375 W 96.8% 95.0% 5000 W 3200 W '4200 W 4200 W 500 V 600 V 600 V 250V 310V 310V 175 – 400 V 250 – 480 V 220 – 480 V 200 – 400 V 211 – 264 V 250 – 480 V 175 / 228 V 250 / 285 V 220 / 285 V . 200 / 228 V 60 Hz; 59.3 – 60.5 250 / 285 V 17A/ 17A 18A/18A 18A/18A 36 A @ combined terminal 36 A @ combined terminal 36 A @ combined terminal 3000 W 3800 W 3500 W 96.8% 95.0% 4000 W 3000 VA 3800 VA 3500 VA 4000 VA 208 V / yes 240 V / — 208 V / yes 240 V / yes 240 V / yes 183 – 229 V 211 – 264 V 183 – 229 V 211 – 264 V 211 – 264 V 60 Hz; 59.3 – 60.5 Hz 60 Hz; 59.3 – 60.5 60 Hz; 59.3 – 60.5 15A13A 16A 17A 1 1 1 1/2 1/2 1/2 <4% <4% <4% 96.0% 96.8% 96.5% 96.5% 96.8% 95.0% 96.0% 95.5% 95.5% 96.0% http://www.sma-america.comlen_US/products/grid-tied-inverters/sunny-boy/sunny-boy-300... 5/3/2011 SUNNY BOY 3000 -US / 3800 -US / 4000 -US. SMA America, LLC Page 3 of 4 DC reverse -polarity protection yes yes yes AC short circuit protection, yes yes yes Galvanically isolated / all -pole sensitive yes /— yes /— yes /— monitoring unit Protection class / overvoltage category . I /III I /III I /III General data Dimensions (W / H / D) in mm (in) 450 / 350 / 235 (18 / 14 / 9) 450 / 350 / 235 (18 / 14 / 9) 450 / 350 / 235 (18 / 14 / 9) DC Disconnect dimensions (W / H / D) in mm 187 / 297 / 190 (7 / 12 / 7.5) 187 / 297 / 190 (7 / 12 / 7.5) 187 / 297 / 190 (7 / 12 / 7.5) (in) Packing dimensions (W / H / D) in mm (in) 390 / 580 / 470 (15 / 23 / 390 / 580 / 470 (15 / 23 / 390 / 580 / 470 (15 / 23 / 18.5) 18.5) 18.5) DC Disconnect packing dimensions (W / H / D) 370 / 240 / 280 (15 / 9 / 11) 370 / 240 / 280 (15 / 9 / 11) 370 / 240 / 280 (15 / 9 / 11) in mm (in) Weight / DC Disconnect weight 38 kg (84 lb) / 3.5 kg (8 lb) 38 kg (84 lb) / 3.5 kg (8 lb) 38 kg (84 Ib) / 3.5 kg (8 lb) Packing weight / DC Disconnect packing 44 kg (97 Ib) / 4 kg (9 Ib) 44 kg (97 Ib) / 4 kg (9 lb) 44 kg (97 lb) / 4 kg (9 lb) weight Operating temperature range (full power) –25 °C ... +45 °C (-13 OF ... –25 °C ... +45 -C (-13 OF ... –25 -C ... +45 °C (-13 OF ... Noise emission (typical) Internal consumption at night Topology Cooling concept Electronics protection rating / connection area Features Display: text line / graphic Interfaces: RS485 / Bluetooth Warranty: 10 / 15 / 20 years Certificates and permits (more available on request) NOTE: US inverters ship with gray lids. Data at nominal conditions Type designation +113 °F) +113 °F) +113 °F) 40 dB(A) www.SMA-Solar.com 37 dB(A) 0.1 W 0.1 W 0.1 W LF transformer LF transformer LF transformer OptiCool OptiCool Opticool NEMA 3R / NEMA 3R NEMA 3R / NEMA 3R NEMA 3R / NEMA 3R yes /— yes /— yes /— opt. / opt. opt. / opt. opt. / opt yes / opt. / opt. yes / opt. / opt. yes / opt. / opt UL1741, UL 1998, IEEE UL1741, UL 1998, IEEE UL1741, UL 1998, IEEE 1547, FCC Part 15 (Class A 1547, FCC Part 15 (Class A 1547, FCC Part 15 (Class A & B), CSA C22.2 No. & B), CSA C22.2 No. & B), CSA C22.2 No. 107.1-2001 107.1-2001 107.1-2001 SB 3000US SB 3800 -US -10 . SB 4000US Home > Products > Grid -Tied Inverters > SUNNY BOY > SUNNY BOY 3000 -US / 3800 -US / 4000 -US SUNNY BOY 8000TL-US / 9000TL-US / 1000OTL-US SUNNY BOY 5000 -US / 6000 -US / 7000 -US / 8000 -US SUNNY BOY 3000 -US / 3800 -US / 4000 -US http://www.sma-america.comlen US/products/grid-tied-inverters/sunny-boy/sunny-boy-300.:. 5/3/2011 STANDARD RAIL L FOOT 3 ALUMINUM STANDOFF 3/8-16 X 3/4 HEX HEAD BOLT 3/8-16 FLANGE NUT O 5/16 X 3-1/2" LAG BOLT 00 000 0 00 Installation Detail ©2008 UNIRAC, INC. 1411 BROADWAY BLVD NE SolarMount Rail ALBUQUERQUE, NM 87102 USA L -Foot PHONE 505.242.6411 UNIRAC.COM Standoff Connection URASSY-0001 S:\AutoCad Detail Library\CAD\URASSY-0001_3in Aluminum Standoff -L Foot -Standard Rail.dwg, 8/22/2008 9:44:52 AM 000UN D 00 n c SolarMount ©2008 UNIRAC, INC. 1411 BROADWAY BLVD NE ALBUQUERQUE, NM 87102 USA PHONE 505.242.6411 UNIRAC.COM UNIRAC-300001 Standard Rail 3/8-16 SS FLANGE Ni 3/8-16 X 3/4" SS HEX NUT 00 � 000UIN[RAC 00 SolarMount/SunFrame ©2008 UNIRAC, INC. 1411 BROADWAY BLVD NE ALBUQUERQUE, NM 87102 USA PHONE 505.242.6411 UNIRAC.COM UNIRAC-310077 4" Aluminum Serrated L -Foot nR 0 0000 ©2008 UNIRAC, INC. 1411 BROADWAY BLVD NE ALBUQUERQUE, NM 87102 USA PHONE 505.242.6411 UNIRAC.COM UNIRAC-310503 3/8-16 X 3/4 FLANGE HEAD SERRATED BOLT 03/8 EPDM WASHER ,75" ALUMINUM TANDOFF TUBE 5/16 X 3-1/2 LAG BOLT ALUMINUM >TANDOFF BASE 2X 08' SolarMount/SunFrame 3" Aluminum Standoff L 3/8-16 X 3/4 HEX HEAD BOLT 3/8-16 FLANGE NUT 000 00 u N IRAC Installation Detail ©2008 UNIRAC, INC. 1411 BROADWAY BLVD NE SolarMount Rail ALBUQUERQUE, NM 87102 USA L -Foot Connection PHONE 505.242.6411 UNIRAC.COM URASSY-0002 Standoffs and Flashings Installation Manual 907 Thank you for purchasing a UniRac product. Please review these instructions completely before proceeding. Standoffs: 3-,4-, 6-, and 7 -inch lengths in each type 4 Shaft Part nos. O.D. Use Components k, Raised flange 310017 I5/8" Use only with SolarMount standard or HD rails. • Welded standoff i zinc -plated steel thru 24 Secure to rafter with 2 lag screws at opposite • 2 lags, 5/16" x 31/2* corners, orienting the flange parallel to the rails. © Flat top 1 -piece 310009 I5/8' Use with SunFrame, SolarMount standard, or • Welded standoff zinc -plated steel thru 16 SolarMount HD rails. Secure to rafter with 2 lag • Bolt, 3/8" x 11/4 - screws 1/4"screws at opposite corners. Secure L -foot or • Lock washer, 3/8 - installer -supplied strut directly to standoff with • 2 lags, 5/16" x 31/2'k standoff hardware. Flat top 2 -piece 310027 11/8 Use with SunFrame, SolarMount standard, or • Shaft aluminum thru 42 SolarMount HD rails. Secure to rafter with 2 • Base assembly �^ lag screws. Secure L -foot or installer -supplied • Bolt 31g' x 1114' strut directly to standoff with standoff hardware. • Lock washer, 3/8" Especially convenient when installing over • 2 lags, 5/16' x 31/2'* f� n a tile roof because flashing can be precisely fitted over secured base prior to installation of shaft. * A lag -bolt removal credit is available wherever an installer prefers to substitute a different lag bolt The installer is solely responsible for determining wheth- er lags are adequate to handle live and dead loads under wind conditions at the installation site. Wind loads and lag pullout capacities are addressed in Code -Compliant Planning and Assembly manuals for SolarMount (Installation Manual 214) and SunFrame (Installation Manual 801.1 or 802). Flashings for flat top I -piece standoffs Flashings for flat top 2 -piece standoffs (11/8" O.D. shaft) and raised -flange standoffs (0/8- O.D. shaft) (see illustrations, p. 2) (see illustrations, p. 3 ) Part no.* Dimensions Part no.* Dimensions Collared, galvanized 990109 8.75" x 12.5" Collared, galvanized 990101 8.75" x 12.5" All metal, aluminum 310044 9" x 12" Collared, aluminum 990102 8.75" x 12.5" All metal, solf aluminum 310045 18" x 18" Collared, soft aluminum 990103 18" x 18" *Packs of 12 flashings. *Packs of 12 flashings. UniRac welcomes input concerning the accuracy and user friendliness Pub 040714 -Iii © 2004 by UniRac, Inc. of this manual. Please write to publications@unirac.com. LL July 2004All rights reserved. UNRRA W Installation Manual 907 The installer is solely responsible for: • Complying with all applicable local or national build- ing codes, including any that may supercede this manual; • Ensuring that UniRac and other products are appro- priate for the particular installation and the installa- tion environment; • Ensuring that the roof, its rafters, connections, and other structural support members can support the ar- ray under building live load conditions; Standoffs and Flashings • Using only UniRac parts and installer -supplied parts as specified by UniRac (substitution of parts may void the warranty); • Maintaining the waterproof integrity of the roof; and • Ensuring safe installation of all electrical aspects of the PV array. Planning and installation There are many possible configurations of standoffs and flashing. The three examples here illustrate major product varieties and installation settings. Example 1 2 -piece, aluminum, flat top standoff Soft aluminum flashing Tile roof SunFrame (shown) or SolarMount rail fts• 2 Remove a tile over a rafter. Install the base of a two-piece standoff, ensuring that both lag bolts are screwed into the rafter. Install soft aluminum flashing over the base, inserting it under the tile above and forming it to the shape of the tile. Insert standoff shaft through the opening in the flashing, screwing it down firmly in place onto the base. Seal with roofing cement or other appropriate compound. Attach L feet to standoffs. Slide L foot mounting bolts along slot on SunFrame (or SolarMount) rail. Insert footing bolts through L feet and fasten with flange nuts. SunFrame rail-j�,!'� Tile L -foot ; / y Mold L� Flashing Raffer to the k- ..J 3 fts• 2 Remove a tile over a rafter. Install the base of a two-piece standoff, ensuring that both lag bolts are screwed into the rafter. Install soft aluminum flashing over the base, inserting it under the tile above and forming it to the shape of the tile. Insert standoff shaft through the opening in the flashing, screwing it down firmly in place onto the base. Seal with roofing cement or other appropriate compound. Attach L feet to standoffs. Slide L foot mounting bolts along slot on SunFrame (or SolarMount) rail. Insert footing bolts through L feet and fasten with flange nuts. Installation Manual 907 — Example 2 1 -piece, steel, flat top standoff No -Calk' flashing Shingled roof SunFrame (shown) or SolarMount rail SunFrame �r Shingle rail L -foot Rafter No -Calk collar —0 Example 3 Standoffs and Flashings VNDRAC Cut an opening in the roofing material over a rafter to accommodate the flashing riser. Install the standoff, ensuring that both lag bolts are screwed into the rafter. Insert the flashing under the shingle above and over the shaft of the standoff. No -Calk collar does not require sealing of the flashing and standoff shaft. Attach L—feet to standoffs. Slide L foot mounting bolts along slot on SunFrame (or SolarMount) rail. Insert footing bolts through L feet and fasten with flange nuts. 1 -piece, steel, raised -flange standoff No -Calk- flashing Shingled roof SolarMount rail No -Calk collar SolarMount rail Shingle Rafter Cut an opening in the roofing material over a rafter to accommodate the flashing riser. Install the standoff, ensuring that (1) both lag bolts are screwed into the rafter, and (2) the raised flange is oriented parallel to the rail. Insert the flashing under the shingle above and over the shaft of the standoff. No -Calk- collar does not require sealing of the flashing and standoff shaft. Slide mounting bolts along slot on SolarMount rail. Insert footing bolts through raised flange on standoff and fasten with flange nuts. P". 3 UWRAw Installation Manual 907 10 year limited Product Warranty, 5 year limited Finish Warranty UniRac, Inc., warrants to the original purchaser ("Purchaser") of product(s) that it manufactures ("Product") at the original installation site that the Product shall be free from defects in material and workmanship for a period of ten (10) years, except for the anodized finish, which finish shall be free from visible peeling, or cracking or chalking under normal atmospheric conditions for a period of five (5) years, from the earlier of 1) the date the installation of the Product is completed, or 2) 30 days after the purchase of the Product by the original Purchaser ("Finish Warranty"). The Finish Warranty does not apply to any foreign residue deposited on the finish. All installations in corrosive atmospheric conditions are excluded.The Finish Warranty isVOID if the practices specified by AAMA 609 & 610-02 —"Cleaning and Maintenance for Architecturally Finished Aluminum" (www.aamanet.org) are not followed by Purchaser.This Warranty does not cover damage to the Product that occurs during its shipment, storage, or installation. This Warranty shall be VOID if installation of the Product is not performed in accordance with UniRac's written installation instructions, or if the Product has been modified, repaired, or reworked in a manner not previously authorized by UniRac IN WRITING, or if the Product is installed in an environment for which it was not designed. UniRac shall not be liable for consequential, contingent or incidental damages arising out of the use of the Product by Purchaser under any circumstances. Standoffs and Flashings If within the specified Warranty periods the Product shall be reasonably proven to be defective, then UniRac shall repair or replace the defective Product, or any part thereof, in UniRac's sole discretion. Such repair or replacement shall completely satisfy and discharge all of UniRac's liability with respect to this limited Warranty. Under no circumstances shall UniRac be liable for special, indirect or consequential damages arising out of or related to use by Purchaser of the Product. Manufacturers of related items, such as PV modules and flashings, may provide written warranties of their own. UniRac's limited Warranty covers only its Product, and not any related items. UniRac, Inc. 3201 University Boulevard SE, Suite 110 505.242.6411 Ns" www.unirac.com Albuquerque NM 87106.5635 USA 505.242.6412 Fax 4 Dill it City of La Quinta Building Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: 3 _ calraA r-4 Owner's Name: A. P. Number: Address:5-3-210cerA Legal Description: City, ST, Zip: i,) Contractor: Contr Fie n : Teleho e Address: — , Project Description: City, ST, Zip: �, PU,)10A. Jr Telephone: ci- State Lic. # : City Lie. #; Arch., Engr., Designer: n s • �1 Address: City, ST, Zip: T ele ho ne: P xx State Ltc. #: of Contact Person: c J lY"t ! Occupancy: Constru tion T e: O u c Y P Y P P o!e t'tYP a (circle one):e): New Add n Alter Repairair Demo Sq. FL: # Stories: # Units: TName Telephone # of Contact Person: — 8 Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW TNS LINE # Submittal Req'd Rec'd Y TRACKING PERMIT FEES Plan Sets Plan Check submitted item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Trgss Calcs. Called Contact Person Plan Check Balance. Title 24 Cates. Plans picked up �, Construction Flood plain plan Plans resubmitted Mechanical r• Grading plan 2°" Review, ready for corrections/issue Electrical 5 .. Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up H.O.A. Approval Plans resubmitted Grading IN HOUSE:- or ssue TJ '`" Review, ready fol-090 Developer Impact Fee r� Planning Approval Called Contact Person 5 I.P.P. --� Pub. Wks. Appr Date of permit issue School Fees TT"otal Permit Fees i b►A WA - eAa.+to.