Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
08698 (SFD)
It Building Address Y' 54-540 Caranz Owner ' u P.O. BOX 1504 78-105 CALLE ESTADO LA QUINTA, CALIFORNIA 92253 mailing Address eft lR A_T_�.a.m...•.t na. City `Zip Tel. San Di( 92107 1 222-4051 Contractor City lZip I Tel. & Classif. 397830 Lic. # 1378 Arch., Engr., Designer Santa Fe Designs Address I Tel. City ip Sta IZ___ __ ILic.t# — LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under p[ovisi, sof Chapter 9`(bo, mencing with Section 7000) of Division 3 of the Business and'Pro essid�ode, and myAicen a is in full forcbi d+� effect.SIGNATUR/ �. TE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that, he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my. employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner:builder will have the burden of proving that he did not build or improve for the purpose of sale.) ❑ I, as .'owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) O 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives 'of this city to enter the above-. mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip BUILDING: TYPE CONST._ .P. Number 774-275-^002--8 OCC. GRP. Legal Description Lot '330 9 ock 302 Project Description 01M Sq. Ft. No. Size 1735 Stories 1 New ❑ Add ❑ Alter ❑ Permit includes stt on PERMIT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS No. Dw. Units Repair ❑ Demolition ❑ fence AMOUNT 271_95 612.50 i 62.00 1.3'3. ns 141.00 6_59 20 _ on 20.00 2076.69 ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES 1ST FL. SO. FT. ® $ UNITS SLAB GRADE 6 ROUGH PLUMB. BONDING t 2ND FL. SO. FT. FORMS YARD SPKLR SYSTEM POR. SO. FT. ® MOBILEHOME SVC. BAR SINK GAR. SO. FT. ® POWER OUTLET ROOF DRAINS HEATING (FINAL) OTHER APPJEOUIP. DRAINAGE PIPING CAR P. I SO. FT. ® TEMP. POLE WALL SO. FT. GROUT DRINKING FOUNTAIN SO FT ® FINAL INSP. URINAL ESTIMATED CONSTRUCTION VALUATION $ WATER SYSTEM WATER PIPING NOTE: Not to be used as property tax valuation =$ FLOOR DRAIN MECHANICAL FEES FRAMING t1j0 / WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER REMARKS: GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED LAUNDRY TRAY AIR HANDLING UNIT CFM FIRE ZONE ROOFING KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET COMPRESSOR HP POLE, TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SO. FT. ® c BATH TUB LATHING f/, WAI SO. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID ® 11/. c SEWAGE DISPOSAL SO.FT.GAR ® 3Ac HOUSE SEWER GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK �� G fly 11 k/ GROUND PLUM GII UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE 6 ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER OR SEPTIC TANK ROUGH WIRING DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) �/ /9 66 LOOP HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu. yd. $ plus x$ =$ LUMBER GR. FINAL INSP. —� —3 — FRAMING t1j0 / A RFINAL INSP. -c ( ✓ ROOFING &4L VENTILATION REMARKS: FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING f/, WAI MESH INSULATIONISOUND FINISH GRADING ,FINAL INSPECTION �— 3 CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURESIINITIALS GARDEN WALL FINAL Tihf 4 P.O. BOX 1504 APPLICATION ONLY Building7&105 CALLE ESTADO Addres— �- (� Y'fcova LA QUINTA, CALIFORNIA 92253 Owner V� ������ \ BUILDING: TYPE CONST. SV�_OCC. GRP. Mailing (� 1 Address q'3 q 4 �� A.P. Number F / i —;;.n b — (\) V �L A Ci Z' V Tel. 1G _Asa_ 35 l Legal Description 3 Contrac or Project Description S— . c_') c— Address _ Cityi—� ZtgjTeI5(D`1'�y'T D State Lic.City & Classif. � C)Lic. / "� # 1 S Ft.•� No. No. Dw. q Size ' Stories Units Arch., Engr. Designer K ( a New Add ❑ Alter ❑ Repair ❑ Demolition ❑ Address� ,� + Tel. ei - a -4,-)S1 Cit `0 v Zi ` � IJ State Lic. # ENSED CONTRACTOR'S DECLARATION 1-1 I hereb affi licensed under pr Ch t mencing with Section 7000) of Div' ' Busi d my license is in full force and effect. �• — ew GN DATE OWNER BUILDER DECLARATION I hereby affirm that I am exempt from the Contractors License Law for the following reason: (Sec. 7031.5,8uskhess and Protesslons Code: any cty or county which requires a permit to oes6uct, aver, irtorove, demoFsh, or repair any structure, prior to its issuance also fagies the appicard for such permit to file a signed statement that he is licensed pursuant to Estimated Valuation ,Oy`1 PERMIT AMOUNT the provisions of the Conhactor's License Law, Chapter B (corrmenccing with Section 7000) of `L)vlstpn 3 of the Busir— and Professlons Code, or that. he Is exempt therefrom, and the basis tor the alleged exemption. Any vbiation of section 7031.5 by 'any applicant for a permit subjects the applicant to a c" penalty of nit more than five hundred doom ($500). o I. as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not Intended or offered for sale. (sec. 7044, Buisness and Professions Code: The Contractors License Law does not apply to an owner of property who builds or improves Umereon and who does such work.hinseff or-through his own employees. provited that such irprovemenis are not intended or offered for sale. t, however, the building or irgovemert is sob within ora year of completion, the owner-bu®de .an have the burden that he did not build or improve tar the purpose of sale.) Plan Chk. Dep. Plan Chk. Bal. Q Const.f Mech. Electrical Plumbing 1, a s owner of the property, am exclusively contracting with licensed contractors to con, strati the project (Sec. 7041, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who bum or inproves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to tie Contractor's License Law.) ❑ 1 an exempt under Sea R_ d P.C. for this reason S. M.1. Grading Driveway Enc. Date • o1111er Infrastructure �- WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self-insure, or a certificate of Workers Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) I Policy No Company ❑ Copy is filed with the City. ❑ Certified copy is hereby furnished. TOTAL REMARKS CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This secton need nor be completed t the permit is for one hundred dollars ($100) valuation or less.) . I certify that in the performance of the work forwhi h this permit is issued, I shall not employ any person ill any manners o ce to the Worke mpensalion aa Lws of ff ri Dat Owner i h10 t, her makiil this 1MMfiEste of Exemption you shooe become subj®ct fo the Mbrkers' Conpensation provisions of the labor Code, you must forthwith comply with such provisions or tall permit shall be deemed revoked. ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line CONSTRUCTION LENDING AGENCY Side Street Setback from Center Line 1 hereby affirm that there is a construction lending agency for the performance of the work for which this permit is iss(red`�n J,oaz,�i.+f Code.) Side Setback from Property Line LerWers Name— Lenders Address This is a building permit when property filled out, signed and validated, and is subject to expiration if work tthefounder Is suspended for 180 days. I certify that I have read this application and state that the above information Is correct. agree to comply with all city and county ordinances and state laws relating to building construction, and hereby au t ives .of city to enter t e ove• mentioned property for ins F/0'W_ Signature or applicant''ice Date dd Malling Add--L FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: City, State, Zip - I FINANCE -- DESERT SANDS UNIFIED SCHOOL DISTRICT 82-879 Highway 111 NOTICE: Indio, CA 92201 Document Cannot Be Duplicated (619) 347-8631 Date 10/18/90 No. 110206 Owner Name Santa Fe Designs No. 54-540 street Carranza Type of Permit La Quinta Permit # 08698 Log # city La Quinta zip 92253 study Area 110 APN # I Tract # Lot # Square Footage 11735 Type of Development Single Family Residence No. of units Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures or replacement inobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE 112is certifies that school facility fees imposed pursuant to Government Code 53080 in the amount ofFIXT1 X 11.735 7 or $ 2,741.30 have been paid to D.S.0 S.D. for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Santa Fe Designs Name on the check Richard M. Beck Director, Facilities Planning & Development Telephone _J:6-141448,4814 Fee collected /exempted by Carlene Ellenz 0 � �' I � __ 77 1-1 _1/ Payment Received Signature Check No. 131 Collector: Attach a copy of County or City plan check application form to District copy. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy - Accounting e+ �� Ile OFFICE OF AGRICULTURAL COMMISSIONER el s AND tsWEIGHTS & MEASURES cnlvlN C. anMINSICAs JAMES O. WALLACE 4080 LEMON STREET, ROOM 19 Aeilelant Comm,sstoner AgtWheal Commrtrlom RIVERSIDE. CALIFORNIA 92501 CLEMENT BENVENISIE. Oheota of welphti A Mea�we� (714) 787.2561 seater t 49613 Highway 86, Suite B12 q / Coachella, Ca. 92236 DA'I'S l� �l �b (619) 342-8291 DATE 90 74- DEVELOPER'S WMA S ADDRESS s; 1 j L /d C Lj,,00 , l 4,j -e - Sa-� TELEPIK=s-- - -��-� Seo Com,-r�H � �w � c•�— 1 Q � Dear Developers (l 4a Cc�c �r � j c Theo- P /e-Pt'S f o toe o P,%,j . fe ccs / 1 After reviewing Your landscaping Plans all plant material listed is not in �. violation of quarantine -laws governing the Coachella Valley. If substitutions �;`• do occur and they differ from plant material listed, this office must be notified` immdiately. Thank u for protecting and preserving the Coachella Valie 's pest-free.environment. you P 9 P 9 lY , . Pe . Y Agricultural Ca 9 i_qv6r I s Of ice ccs Indio and Riverside Office min PIBM ( �� V �' 7 ..r.oe I i i ' 1 � + d � � � I r i j ( I of , 1a U n a a ii ca* l tbVan ;j ; This Certificate issued pursuant to the requirements of Section 306 of the Uniform Building' :I'. Code certifying that at the time of issuance this structure was in compliance with the various 1 , ` h l it ,; W. ordinances of the City regulating building construction or use. For the following. BUILDING ADDRESS 54-540 Carranza Use Classification SFD Bldg. Permit No. 08698 Group R3 _Type Construction VN Fire Zone Use Zone SR Santa Fe Designs 4344 Newport Avenue Owner of Building Address Cit Die Diegou CA 92-1 By:Mark Harold July 3,"1991 Date; Building OfficialPOST IN A CONS . VICUOUS PLACE REM M T419� 78-105 CALLE ESTADO - LA QUINTA, CALIFORNIA 92253 - (619) 5642246 Oct q October 24, 1990 Tim Langston F & F Pools 80-975 Indio Blvd.. Indio, CA 92.201 Dear Mr. Langston: Subject: Setback Adjustment #90-031 Location: Cove 54-540 Carranza APN: 774-275-002 Legal: Lot 23, Blk 307 This letter is to report approval of your recent. application for a setback adjustment, pursuant to Chapter 9.188 of the City of La Quinta Planning & Zoning Regulations. The following setback adjustment has been approved subject to conditions and in accordance with attached Exhibit A. SETBACK ADJUSTMENT: Pool: 3 feet from side property boundary and house Pool Equipment: 8 feet from rear property boundary FOR: Swimming pool & pool equipment CONDITIONS: 1. -Comply -with Municipal Code Fencing requirements for pools. 2. Ensure pool is reinforced to building code requirements. After review and the attachment of conditions it was determined that: 1. This adjustment is consistent with the intent and purpose of the zoning ordinance. 2. There are special circumstances applicable to the property, including .such factors as size, shape, topography, location or surroundings that justify approval of the adjustment. These special circumstances are: this is a small lot with limited space for a pool. J MAILING ADDRESS P.O. BOX 1504 - LA QUINTA, CALIFORNIA 92253 LTRGL.104/CS -1- 3. This adjustment will not be detrimental to the health, safety, and general welfare of the community or be detrimental to property in the vicinity of the parcel for which the adjustment is requested. Should you have any questions, please contact the undersigned. very truly yours, JERRY HERMAN PLANNING & DEVELOPMENT DIRECTOR . Gt Ia-ok.�AA s . Glenda M. Lainis Assistant Planner GML:ccs Attachment: Exhibit A cc:Buldi'ng: &` S_ afe_ty De --p -- LTRGL.104/CS -2- EXHIBIT CASE NO. qC-) Mrs FiF Designed For Mr./Mrs. 5 'VA6r# 'fe '"wa "'eV4 Address: "I-010 w� Cther GUNITE 3.000 aaa 5KTI ON THROUGH POOL Imoulse Unit - 0 maimenartca oat Pad vac t=L Hosv Soda DM Board all '!US CONTRACTOR NOM ON RVJVW to1-Z&H,0 Surface jKo'; SPA Siz. =AZ Total Total Perim EXCAVATION c4tricrete S SC Sturno Removal TEEL S STEEL 090 roes yes C, PWMBINGT Cther GUNITE 3.000 aaa 5KTI ON THROUGH POOL Imoulse Unit - 0 maimenartca oat Pad vac t=L Hosv Soda DM Board all '!US CONTRACTOR NOM ON RVJVW ' Point System Summary: Climate Zone 15 BUILDING DATA Conditioned Floor Area (� 3 Number of Stories Slab/Raised Floor S \—A15. Check all applicable Unit Type condition(s): Single Family Detached (31.71)) (] Addition Alone (J Single Family Attached (FFA) [ ] Existing Building [) Multi. -Family (MF) [ ] Existing-?lus-r►ddition P -'1F ���.`J s Gl % Glass North ' I . East ""i South West Skylight b Total SCORECARD Measures Point Scores 1. Ceiling Insulation �- � � or � R -value (38] U -value [0.030] 2. Wall Insulation f;�, \ '� or p R -value (19] U -value [0.066] 3. Raised Floor Insulation1 or t� R-valuc 1191 U -value [0.037] 4. Slab Edge Insulation C5 or o R -value (0] F2 factor (0.77] S. Infiltration Standard ( 0 6. Glass Heat Loss T • G :Z-4 �. Type (double] U -value (0.65] %Total Glass (161 Sum 1-6 ' 7. Shading (Shade Open) % GlassC ff. % lass a. North -so 5A Z x .Z( 4 = • 15 p b. East _ o x _ O c. South 1 _ x_ 5 �' �TJ d. West Z kP x7?,j �o _ 8 l 1p O e. Skylight C> x C:7 = l7 D 8. S�iading (Shade Closed) % Glass Eff. % Glass a. North(� - x -. = I. t,l & C. Soutti x °1 -e = �� d. gest Z 7L, x Z _ 1 I e. Skylig%:t x O 0_ 9, Interior Thermal Mass `-1 ► 4 '� 3 Inutio O —�— 10. Exterior Wall Mass `. Exterior Wall Mass S 7-10 11. heating System 2� � x ae>= Z Zonal Control? ( Y / N) SE or HSP_F Duct Efficiency (0.781 Effective SE or 10.72/6.6 HS (0.56/5.15] .�(. -a --s 12. Cool . -mg System � k .I O x 83 = r 4 11 Zonal Control? ( Y / N) SEER (9.5] Duct Efficiency [0.74) Effective SEER 17.031 13. Water Heating SE© -� Type [SG] Credit (none] Point Total: Form Revised March 1988 ` Certificate of Compliance: Residential (Page 1 of 2) CF -1R Project Title F(� C Date Project Address \`---\ .�✓,� Li t ��� -Sk40 Z�Q3. Building Pemtitrf Docu tad n Author Telephone 7th \0 lJ r <�;~; S M ' S Checked By / Date Compliance Method (PsUage, Point System or Computer) Climate Zone Enforcement Agency Use only GENERAL INFORMATION Total Conditioned Floor Area: ft2 Building Type: Single Family Hotel/Motel (check one or more) Multi -Family (less than 4 stories) Addition Multi -Family (4 or more stories) Existing -Plus -Addition Front Entry Orientation: North / East / South / West / All Orientations (circle one or more) Number of Dwelling Units: '— _ Floor Construction Type: Slab / Raised Floor (circle one or both) Infiltration Control: Standardfright (circle one) BUILDING SHELL INSULATION Component Insulation Location/Comments Type R -Value (attic, to garage, typical, etc.) GLAZING Glazing Orientation Front.... (a) Front.... ( ) Left...... (W) Left...... ( ) Rear..... (s) Rear..... ( ) Right.... (iE) Right.... ( ) Skylight....... Skylight....... Area (Sf) THERMAL MASS Glass Type (single, double) Shading Devices Interior Exterior . (roller blind, etc.) -,I c:> ►J ca Overhang Framing Type Type/Covering Area Thickness (slab/exposed, tile, etc.) (sf) (inches) Location/Description(kitchen, bath, etc.) 7—\ A10 Z Certificate of Compliance: Residential (Page 2 of 2) CF -1R Cts. - ` '^"-r-A Cr-- 7�>L ct CA i\" 20 S Project Tide Date HVAC SYSTEMS Minimum Duct Type (furnace, air Efficiency Location Duct Output Manufacturer / Model # conditioner, heat Dump) (SE, SEER.HSPF) (attic, etc.) R -Value (Btuh) (or approved equal) /\\'(t.ykQN3k�V Arc �c yt>c>oE> �-eas� . L o . 4 L -L-- QKL 1. ) Maximum Furnace Heating Output: � Btuh HOT WATER SYSTEMS Tank JyStem Type (storage gas, etc.) S!dzA s EK ��'(SZ Manufacturer/Model # (or approved equal)__ SPECIAL FEATt7RES/REMARKS (Add extra sheets if necessary) z . COMPLIANCE STATEMENT - This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Chapter 2-53 and Title 20, Chapter 2, Subchapter 4, Article 1 of the California Administrative code. This certificate has been signed by the individual with overall design responsibility and the building owner, who shall retain a copy of it and transmit the certificate to any subsequent purchaser of the building. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, all building conservation features which vary are indicated in the Special Features/Remarks section. Designer Name: Title/Firm: P ,� Address: J Telephone: % Lic. ti: (signature) r_r (date) Documentation Author , r Name: Title/Firm: Address: (date) Form Revised March 1998 Building Owner Name: .`�C (�Y 1 VIC bv-;�GQIS Enforcement Agency Name: Agency: Telephone: (signature or stamp) (date) Mandatory Measures Checklist: Residential MF -1R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are, shown elsewhere, in the, documents or on this checklist only. DESCRIPTION Building Envelope Measures §2.5352(a): Minimum ceiling insulation R-19 weighted average. §2.5352(b): Loose fill insulation manufacturer's labeled R -Value. �* 52.5352(c): Minimum wall insulation in framed walls R-11 weighted average (does not apply to exterior mass walls). §2.5352(k): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. §2.5311: Insulation specified or installed meets California Energy Commission (CEC) quality standards. Indicate type and form. < §2.5352(1): Vapor barriers mandatory in Climate Zones 14 and 16 only. §2.5317: Infilaation/Exfiltradon Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Doors and windows certified. c. Doors and windows weatherstripped; all joints and penetrations caulked and sealed. §2.5352(e): Special infiltration barrier installed to comply with §2-5351 meets CEC quality standards. _"'-,§2-5352(d): Installation of Fireplaces 1. Masonry and factory -built fireplaces have: a Tight fitting, closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. HVAC and Plumbing System Measures §2-5352(8) and 2-5303: Space conditioning equipment sizing: attach calculations. §2-5352(h) and 2-5315: Setback thermostat on all applicable heating systems. §2-5316(1): Ducts constructed, installed and insulated per Chapter 10, 1976 UMC. §2-5316(b): Exhaust systems have damper controls. §2-5314(c): Gas-fired space heating equipment has intermittent ignition devices. §2-5314: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. §2-5352(i): Water heater insulation blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater); first 5 feet of pipes closest to tank insulated (R-3 or greater). §2-5312(Exception I): Pipe insulation on steam and steam condensate return & recirculating piping. §2-5318(d): Swimming Pool Heating 1. System has: a. On/off switch on heater. b. Weatherproof instruction plate on heater. c. Plumbed to allow for solar. 2.75 percent thermal efficiency. 3. Pool cover. 4. Time clock. 5. Directional water inlet. DESIGNER I ENFORCEMENT Lighting and Appliance Measures §2-53520): Lighting - 25 lumens/watt or greater for general lighting in kitchens and bathrooms. §2-5314(c): Gas fired appliances equipped with intermittent ignition devices. §2-5314(a): Refrigerators, refrigerator -freezers, freezers and fluorescent lamp ballasts certified I by the CEC. Indicate make and model number. Farts Revved December 1997 Insulation Certificate Number and Street City County Subdivision Lot Number Description of Installation ROOF Material Brand Name Thickness (inches) Thermal Resistance (R -Value) EXTERIOR WALL Material Thickness (inches) ..0 ILING Brand Name Thermal Resistance (R -Value) Batt or Blanket Type Brand Name Thickness (inches) Thermal Resistance (R -Value) Loose Fill Type' Brand Name Contractor's minimum installed weight/ft lb Minimum thickness inches Manufacturer's installed weight per square foot to acheive Thermal Resistance (R -Value) RAISED FLOOR Material Thickness (inches) SLAB FLOOR Brand Name Thermal Resistance (R -Value) Material Brand Name Thickness (inches) Thermal Resistance (R -Value) Width (inches) FOUNDATION WALL Material Brand Name Thickness (inches) Thermal Resistance (R -Value) Declaration I hereby certify that the above insulation was installed in the building at the above location in conformance with the current Building Energy Efficiency Standards for new residential buildings contained in Title 24 of the California Administrative Code. General Contractor (Builder) License Number Signature and Title Date Sub -Contractor (Insulation Installer) License Number Signature and Title Date Proposed Construction Assembly: Residential Form 3R R 14b Project Tltle Date Pro) d ` n `, ks. C1,,11� �Z Z, 9 BuildingPermitN Docurnenikon Author Telephone 1 _ ��a •��� < `� _Q\ —tt� Checked By/Date Assembly Name \ Enforcement Agency Use Only Z Sketch of Construction Assembly List of Construction Components Outside Surface Air Film 1. . 87S " SSV (-- Assembly Type: (check one) Framing Material: Framing Size: Framing Spacing: Framing Percentage: (check one) Wall Weight / sf: (Packages only) 2.3 2.�Sv\-A-T-\�oa 3. 4. 5. 5. 6. 7. Floor Wall Ceiling/Roof Z x �P " O.C. Wall: 15% (16" o.c.) 12% (24" o.c.) Floor/Ceiling: 10% (16" o.c.) 7% (24" o.c.) R -Value Cavity(Rc) Frame(Rr) .1$ Inside Surface Air Film . Total Unadjusted R -Values: Re Rf Framing Adjustment Calculation (if applicable): ( x ) + ( x ) _ , o us 1/Rc 1-(Fr%/100) 1/Rf Fr%/100 Total U -Value I/Total U -Value Total R -Value Proposed Construction Assembly: Residential Project'ritle Form 3R Pro Building Permit M DDooc'u`m�entadon.�Auut-h-+or \ `—? Telephone Checked By / Date Assembly Name Woraenent Agency Use Only Sketch of Construction Assembly A Assembly Type: (check one) Framing Material: Framing Size: Framing Spacing: Framing Percentage: (check one) Wall Weight / sf: (Packages only) Floor Wall 1` Ceillng/Roof Z x 1� 14 " o.c. Wall: 15% (16" o.c.) 12% (24" o.c.) Floor/Ceiling: 10'0 (16" o.c.) 7% (24" o.c.) V List of Construction Components R -Value Cavity(Rc) Frame(Rr) Outside Surface Air File► 61 2. .5O 7 L`{ W 0,U Z 5. 6. 7. Inside Surface Air Film +� Total Unadjusted R -Values:, O Rc Rr Framing Adjustment Calculation (if applicable): 1/Rc 1-(Fr%/100) 1/Rf - Fr%/100 Total U -Value 1/rotal U -Value Total R -Value 7 Shading Coefficient (SC). Worksheet Form.S Items 1 - 9a and 10a must be completed for glazing/shading combinations not found in Table 0-9 of the ECM by using documented manufacturers' data for the specific conditions indicated (#2, #8 and #11). For instructions on filling out the worksheet, see Shading in the ECM Glossary. For overhang SC values (# 14 and # 15), see Section 4.2 in the ECM. General Information 1. Glazing Type: 2. SCglazing alone: 3. Framing Type (metal/wood): 4. Mullions (yes/no): 5. Framing/Mullion Factor: (from Table G-10) 6. Interior Shade Type: 7. ` SCshade open: 1.00 8. SCshade closed: (SC of shade w/ clear single glass) Glazing, Interior Shade & Framing g 9a. [( x 0.25) + 0.75] x x = SCS - SC„dn FMF (#5) SC Shade Open or 9b. (from Table 0-9) SC Shade Open 10a. [( x 0.25) + 0.751 x x = SCrnax SC,nin FMF (#5) or 10b. (from Table 0-9) SC Shade Closed c SC Shade Closed Where: SCmax = larger of #2 and #7 SCmin = smaller of #2 and #7 Where: SCmax = larger of #2 and #8 SCmin'= smaller of #2 and #8 Exterior Shade Exterior Shade Type: 11. SCexlerior shade:. l (from Table G-11 or manufacturer's data w/ clear single glass) ! Where: 12.' x 0.25) + 0.751 x �� _ .Z� SC►nax = larger of #9a or #9b and #11 SCMaX SC,,,In SC Shade Open SCmin = smaller of #9a or #9b and #11 7 ; r Where: -� ' 13. [(' x 0.25) + 0.751 x -3 = .. '� �Q SCmax = larger of #1 Oa or'#10b and #11 SC,na r Scadn SC Shade Closed SCmin —smaller of #10a or #10b and #11 Overhang (Point system Only) 1.4. Overhang Factor (Shade Open) 15. Overhang Factor (Shade Closed) Farm Revised March 1988 X SC Shade Open (#12) X SC Shade Closed (#l3) Projection Ratio: SC Shade Open (with Overhang) SC Shade Closed (with Overhang) C WORKSHEET ONE: STORAGE TYPE GAS OR STORAGE TYPE ELECTRIC FOR SHOWING COMPLIANCE WITH RESIDENTIAL BUILDING ENERGY EFFICIENCY STANDARDS WATER HEATING BUDGETS A EOUIPMENT DATA 1 Water heater type S Enter SG or SE 2 Manufacturer Ao SM NTA From building plans 3 Model number S From building plans 4 Ignition device GP, gas pilot or IID, intermittent ignition device 5 Tank volume W Total gallons, from CEC Appliance Directory 6 Recovery efficiency •A Percent from CEC Appliance Directory x .01 7 Standby loss Percent/hour, from CEC Appliance Directory 8 Rated input 5 Btu/hr, from CEC Appliance Directory Ambient air temp. (1 kWh = 3413 Btu) 9 Number of Heaters From building plans (total) 1 Climate Zone 2 Water heating budget 3 Tank set temp. 140 4 Water main temp. -0 5 Daily hot water load 50 6 Ambient air temp. L 7 Adj Standby Losses 8 No. dwelling units 9 Number of pumps 1(E�' 10 Pumping energy B See Appendix D KBtu/yr/unit, see Table 1 OF, fixed input OF, see Table 1 50 or 35 gallons/unit, see Table 1 OF, see Table 1 See Table 2 � O 0- 4 'c Sq 5 From building plans (total) From building plans Watt-hr/yr, see Table 3 C WATER HEATING ENERGY CREDITS 1 Credit name -© See Table 5 2 Annual savings - KBtu/yr/dwelling unit, see Table 5 D CALCULATE ANNUAL WATER HEATING ENERGY (KBtu/yr) 1 Recovery load l0 5 3 g ([B5 x 8.25 x (140-B4) x 365 x .001] - C2) x B8 2 Recovery energy 3 Standby loss energy -5 4 Pumping energy D1/A6 (24 - [(D2 x 1000)/(A8 x A9 x 365)]) x 8.25 x A5 x B7 x 365 x (140-B6) x .001 x A9 B9 x B10 x 3.413 x 3 x .001 5 Total energy 3 4 ` GAS SYSTEMS: (D2 + D3 + 04)/B8 ELECTRIC: ([(02 + D3) x 3] + D4)/B8 6 Water heating budget q comparison* —ZSS� KBtu/yr/unit B2 - D5 7 Water heating budget Points (06/conditioned floor area.per dwelling unit) x 2 C _ 1 point = .5 KBtu/yr * If positive, the system complies. If negative, the system does not comply. Water Heating 649 `C1lc� Niel, . ,oet 1; LA .I �o PROJECT DATA SUMMARY S�,f�tA Tj or&� owner NLS� C project Form 1 checxec oy nate cocumentatiorvautnor Sate Electric Resistance Life Cycle Cost (from Form 5) .................................... sLCCe SITE INFORMATION �Z\ Lowest Life Cycle Cost of the Other Systems (from Form 5) ................... sLCC,,.w 21 g Non-Dapletable Energy w/Electric Resistance Back -Up Heating Degree Day (from Appendix C) .......................................................... HOD 1 `Z—�Z °F•day Source (from Calculations)................................•.............................................. Outside Design Temperature (from Appendix C or Appendix G) ...................... Tow 2 OF PROPOSED BUILDING ENVELOPE INFORMATION (from Calculations) % Gross Floor Area if Low -Rise (from Calculations) ............................................ At 3 ft2 Gross Wall Area if High -Rise (from Calculations) ............................................ Aw 4 ( ft2 Lowest Life Cycle Cost of the Other Systems (from Form 6) ................... Designed Glazing Area (from Calculations)....................................................... Ag 5 2S ;, ft2 . pLCCs Babe Glazing Aria 116% of Line lii low-rise or 40% of Line 4 if hign nsei........ Ayg 6 _Z --t ft2 Oescriotion of Assemoty T 1)QA\.. � Glazing U91 7 Btu/ lhr•ft2.°F) Ug2 8 Btu/ (hr. ft2 •°F) \�%CC.� �- ( " �ZN LPAA `— Ug3 Btu/ Ihr.ft2•OF) Wall \ wl 10 Stu/ (hlr.ft2 •°F) Uw2 11 Btu/ (hr. ft2 • °F) Uw3 12 Btu/ (hr. ft2 • °F) U -�1i1 �� �— \�'� 13 0 Btu/ Ihr• ft2 •°F) Culling/Roof `�Ucwa ! 14 Btu/(hr•ft2•OF) Ut2 15 Btu/ (hr • ft2 • °F) Floor U11 16 Btu/ Ihr•ft2 •OF) Uf2 17 Btu/ (hr • ft2 • °F) PROPOSED SPACE HEATING SYSTEM (Chapter 7) Gat Furnace -�;o'ZZ Building Design Hourly Heat Loss (from Form 2) ..................................... d 18 Btu/hr Maximum Allowed Bonntn Caoacity, T Line 18 ............................................... 19 Btu/hr Proposed Furnace \' Make Model Description Rated Sonnet Capacity Electric Resistance Alone Electric Resistance Life Cycle Cost (from Form 5) .................................... sLCCe 20 S Lowest Life Cycle Cost of the Other Systems (from Form 5) ................... sLCC,,.w 21 g Non-Dapletable Energy w/Electric Resistance Back -Up Percentage of Annual Heat Loss Met by Non•Oepleteble Energy Source (from Calculations)................................•.............................................. 22 % Heat Pump Percentage of Annual Heat Loss Met by Electric Resistance (from Calculations) % PROPOSED WATER HEATING SYSTEM INFORMATION (Chapter 8) Eleettic Resistance Alone Electric Resistance Life Cycle Cost (from Form 6) ................................. wLCCe 24 $ Lowest Life Cycle Cost of the Other Systems (from Form 6) ................... wLCCO m 25 $ PROPOSED SWIMMING POOL HEATING SYSTEM INFORMATION (Chapter 9) Solar Life Cycle Cost (from Form 7)............................................................... pLCCs 26 $ Natural Gas Life Cycle Cost (from Form 7) ...................................................... pLCChg 27 $ HOURLY AND ANNUAL BUILDING HEAT LOSS RATF� Chw* One: Proposed Design Standard Design S s�-r a t/CCS.\ �•,t�s S I '1 owner orolea orciect to tion tys em type aocumentation autnor gate Forma 2R • (8/81) forcement AgencY Use Only ou+to+ng permit number cnecxep oY Cate SITE INFORMATION` Heating Degrea Oav("am Appendix) ................. MOO Z °F• day Outside Oeeign Temperature (from Appendix) Tow 3 F Outside January Mean Temperature (from Appendix) . . . . .. . . . . .. . Tian r�oF PROPOSED BUILDING ENVELOPE INFORMATION Gros Floor Ana (from plans) ..... . ........ ... . .. .. .... . Af ft2 Gros Well Area (from plans) ............ .... .... .... ... Aw \ Z.. h2 Oasignsd Glazing Area (from plans) . .... . ....... . .. .... . A9 -Z-� ft2 Buie Glazing Area 116% of Af if low-rise or 40% of Aw if high•eisel .. .. .. .Aye ft2 HOURLY HEAT LOSS DESIGN TEMPERATURE DIFFERENCE For All Assemblies Other Than The Three Below. .70°F - ; l of ■ &Th 1 ��°F Tory from aoove For Insulated Floor Over Vented Unheated Space .... .. .... Line 1 =2 •&Thi 2 °F For Uninsulated Floor Over Vented Unnamed Space........ Line 2 - S°F •&Thu 0 �r °F For Slab -on Ground Flows . . . ........ 7eF - of ■ &Th, 4 w °F Tian from aoove CONDUCTIVE HEAT LOSS 51-um—Q176 Average U gCco O� INFILTRATION ...... ����n2x ft � x Area, ft2 or of AssamolY. Of F2 from &T hourly heat Oescriotlon.of AWmaly Lengtn, rt Graon 41 from Ove ( loss.f4 - 1�AJ - l •, 1 Z�- • 5 s Stu/hr Glazing x x Cadinq/Roof J \'_rzV PC -`W Floor 7, l 5 X_ X a `1 L' x O 13.-Z=77—: Z Z Q X_ x x x �xx a O Z\ 1 x \S12�10 volume Subtotal 51-um—Q176 um o +e aoove o gCco O� INFILTRATION ...... ����n2x ft � x Al from aoove weigntso from UT, fro Average Table 3.7 Una 1 Calling FNignt `� 5 Subtotal 7 to/hr n. • ,1�3 DUCT HEAT LOSS iEnter 0 if there are no ducts) .................. 0.14 x Line 7 B �0 7-Z TOTAL HOURLY HEAT LOSS,a t. 9 to/hr line ne ANNUAL -HEAT LOSS, OL ` °F day/Yr x Btu/hr x 1 x 24 hridav ♦ OF • Mouriv Meat iris C from 10 e—"� `b to/yr MOO 41 Th from from above from Line 9 Table 3.8 Lane 1 �> <z2.s? s y r�? QIA .<5rl S } cam-' n ► Lv 1\ (1951 .X 4 Z sal � \3 SUMMARY Form 2 page 2 of 2 *roleet "t'. climate :one l 3roiect adorns HEATING, VENTILATING, AIR CCNOITIONING SYSTEM Points 10. Heating (fill in information on proposed system) Canal Gas Furnace % orana and mcael number SE Stu/hr ` ,�.• ,l \ Floating aoauty _ Heat Pump `�JQ Z\k �Q � Q — QQ*read and modat numoar ACOP 413 d 005 Btu/hr Rooting aoauty at +7dA Active Solar type Uldwa or alri collaRor Find dna maedi numoar four rraalon fta 0 cotlocor area collector orientation oauoctor tut nceo raced stood y • Intercept Other aescloo 11. Cooling (fill in information an propasea system) Electric Air Conditioner brand and model number seasonal EEA cooling caoauty at 9e" e Stu/hr Electric Heat Pump �x <Z> `c:i, Btu/hr cooling aoauty at 953? Other aosuloe 12. Mechanical Ventilation A04 adacrlbe, DOMESTIC WATER SYSTEM 13. Heating (fill in information on proposed system) Gas Only Gallons *rano and moan numoar tanx uad Heat Pump w/Electric Backup Gallons brand and model number tanx alje Active Solar collector brand and model numoor 2ta0 Met! 11020. solar traction y - Aterceot ft' oacxuo neater type, brandand model number cosi*=or area Collector Other' �U� C � 'M � -� - �j� �lencacwn Point Total from Page 1 Total Point Score zees • a=o • cEc .1 C C OC19 AND CBH19 SERIES B UP -F DOWN- LO & HORIZONTAL HEAT PUMP BLOWER -COIL UNITS RFCIIITM or EXPANSION VALVE SYSTEM *19,600 to 61,000 Btuh Cooling Capacity *19,200 to 59,000 Btuh Heating Capacity 6,400 to 102,400 Btuh Optional Electric Heat *At ARI Standard 240 Ratings with Matching Outdoor Unit The CB19 and CBH19 blower coil units are designed for multi - position installation in a basement, utility room, alcove, closet, crawlspace or attic. Versatile units are applicable to expansion valve systems or RFCMT'M' (Refrigerant Flow Control) systems. Several models are available in varying sizes with a wide range of heating and cooling capacities. See Heat Pump Outdoor Unit bulletins indexed in this tab section. Optional field installed electric heaters are available in several sizes for supplemental heating capacity. CB19 models are applicable to up-flo or down-flo discharge air applications. Units are shipped for up-flo applications and may easily be field converted to the down-flo position by turning the unit upside down and repositioning the coil, drip shields and cabinet access panel. Filters are not furnished and must be provided by the installer. An optional side return air adapter with filter(s) is available for up-flo models only. An optional additive base is available for models with electric heat installed in the down-flo position on combustible floors. CBH19 models are designed for horizontal discharge air applica- tions. Units are furnished with left hand air discharge as standard and may be field changed to right hand discharge by turning the unit over (end for end) and repositioning the coil. CBH19-51 and CBH19-65 models are furnished in a two piece cabinet with blower and optional electric heaters in one section and the indoor coil in the other. Hardware is furnished for field connection of cabinets. Filters are not furnished and must be provided by the installer. Up -Flo Installation with Filter Adapter CB19 MODEL — UP-FLO ENGINEERING DATA HEAT PUMPS MATCHED REMOTE SYSTEMS Page 29 September 1988 CB19 MODEL — DOWN-FLO CBH19 MODEL — HORIZONTAL Typical Applications Horizontal Installation NOTE — Specifications, Ratings and Dimensions subject to change without notice. Down -Flo Installation ` SPECIFICATIONS tAnnual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. 'Must be ordered extra for field installation. CHECK AND EXPANSION VALVE KITS Blower -Coil Model No. CB19-41 CBH19-41 CB19-51 CBH19.51 CB19-65 CBH19-65 Blower section 1000 ---• ---• ---- B19-51 ---- B19-65 Indoor coil section HP19-261 ---- ---- ---- CH19-51 ---- CH19-65 Indoor Coil Net face area (sq. ft.) 5.27 5.27 7.0 7.22 7.0 7.22 Tube diameter (in) & no. of rows 318 - 3 318 - 3 318 - 3 3/8 - 3 318 - 3 318 - 3 Fins per inch 13 13 14 14 14 14 Vapor line connection (in.) -flare 3/4 3/4 314 3/4 1-1/8 sweat 1-1/8 sweat Liquid line connection (in.) -flare 3/8 3/8 3/8 3/8 3/8 3/8 Condensate drain (mpt) in. (2) 3/4 1 (2) 3/4 (2) 3/4 1 (2) 3/4 (2) 3/4 (2) 3/4 Nominal cooling capacity (tons) 3 4 5 Refrigerant R-22 R-22 R-22 Blower wheel nominal diameter x width (in.) 10 x 9 12 x 8 12 x 9 Blower motor hp 1/3 1/3 1/2 Electrical Characteristics 2081230 volts -60 hz-1 phase 2081230 volts -60 hz-1 phase or 460 volt -60 hz-3 phase Shipping Weight (lbs.) Blower section Coil section 167 178 209 118 122 213 120 122 Number of packages in shipment 1 1 1 1 2 1 2 'Optional Side Return Air Filter Adapter (Up -Flo only) Part No. LB-59776CB -•-• LB•59777CA ---- LB•59777CA ---- No. & size of filters (in.) (1) 20 x 20 x 1 (2) 16 x 25 x 1 (2) 16 x 25 x 1 Shipping weight (lbs.) 5 •--- 24 ---- 24 ---- *Optional Down -Flo Combustible Base Pert No. LB-59697BB LB -596978C ---- LB-59697BC ---- Shipping weight (lbs.) 8 -•-- 8 ---- 8 ---- 'Optional Electric Heat Capacity EC619-5 Output Btuh 18,000 18,000 19,000 19,000 ---- ---- tA.F.U.E. 100% 100% 100% 100% ---- ---- ECB19-6 Output Btuh 22,000 22,000 23,000 23,000 ---- ---- tA.F.U.E. 100% 100% 100% 100% .... .... EC B 19-7 Output Btuh 25,000 25,000 26,000 26,000 ---- ---- 1A.F.U.E. 100% 100% 100% 100% ---- ---- ECB 19-8 Output Btuh 29,000 29,000 29,000 29,000 30,000 30,000 tA.F.U.E. 100% 100% 100% 100% 100% 100% ECB19-10 Output Btuh 35,000 35,000 36,000 36,000 37,000 37,000 tA.F.U.E. 100% 99.9% 100% 100% 100% 100% EC819-12.5 Output Btuh 44,000 44.000 45,000 45,000 46,000 46,000 tA.F.U.E. 100% 99.9% 100'/0 100% 100% 100% ECB19-15 Output Btuh 53,000 53,000 53,000 53,000 54,000 54,000 1A. F. U. E. 100% 99.9% 100% 100% 100% 100% EC619-20 Output Btuh 70,000 70,000 70,000 70,000 71,000 71,000 tA.F.U.E. 100% 99.8% 100% 99.8% 100% 100% ECB19-25 Output Btuh ---- 87,000 87,000 88,000 88,000 1A. F.U.E. •... 100% 99.8% 100% 99.9% ECB 19-30 Output Btuh .--- ---- 105,000 105,000 tA.F.U.E. -•-• ---- ---- 100% 99.9% tAnnual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. 'Must be ordered extra for field installation. CHECK AND EXPANSION VALVE KITS Blower -Coil Outdoor *Check and Expansion Unit Unit Valve Kit CB19-21 .03 1000 CB H 19-21 HP19-211 LB-34792BE CB19.26 1 .08 1600 1800 CBH19-26 HP19-261 LB-34792BE CB19-31 .10 2400 CB H 19-31 HP19-311 LB-34792BG CB19-41 CBH19-41 HP19411 LB-34792BG CB19-51 CBH19-51 HP19-461 LB-34792BG CB19-51 CBH19-51 HP19-511 LB-34792BF CB19.65 CB H 19.65 HP19-651 LB-34792BH BLOWER DATA UP-FLO SIDE RETURN AIR FILTER ADAPTER RESISTANCE Air Volume (cfm) Filter Resistance (in. wg.) 400 .01 600 .02 800 .03 1000 .05 1200 .08 1400 1 .08 1600 1800 .08 .09 2000 9 2200 .10 2400 .10 'Kit must be ordered extra and field installed. - 30b - Vb 1.1/16 E D J_ SUPPLY AIR OPENING TOP VIEW AIR FLOW 1 \. J U.L. INSTALLATION CLEARANCES — ALL MODELS Cabinet 0 inch Plenum and Outlet duct on blower/coil units 1 inch Plenum and warm air duct within 3 feet of cabinet Inch Floor •Combustible 'When unit is installed in the down-flo position with electric heat on a combustible floor an optional down-flo base is required. DIMENSIONS (inches) CB19 UP-FLO POSITION OPTIONAL t: ELECTRIC HEAT IField Imtell41 CLCM I rtl ,.L I _ CB19-31 & 41 INLETS 1�O1110101[Ilm 48 (Both Sides) -----j------- B 18-1/4 j I 23-1/4 c23-1/4 _ I I 23-1/4 25-1/4 I BLOWER j 18 18 . 1 r / E 15-7/8 19-1/8 20-7/8 F 21-7/16 21-7/16 LIQUID r---------1 15 UNE I`I N— 2.1/2 VAPOR I 11-5/8 LINE P RETURN AIR, 10-1/4 ...,11-3/4 1 OPENING I 8-1/8 4-1/4 (Either Side L 7-5/8 I or Bottom) I 10-1/8 M 4-1/4 4-3/4 Mod No. el C819-21 & 26 CB19-31 & 41 C619-51 & 65 A 48 51 60 B 18-1/4 21-1/2 23-1/4 c23-1/4 23-1/4 23-1/4 25-1/4 D 18 18 . 20 E 15-7/8 19-1/8 20-7/8 F 21-7/16 21-7/16 23-7/16 G 15 18.1/4 20 H 9-1/8 10-3/4 11-5/8 J 7-1/2 10-1/4 ...,11-3/4 K 8-1/8 4-1/4 10 L 7-5/8 9-1/4 10-1/8 M 5-3/4 4-3/4 7-3/4 N 9PL 18-1/4 18-1/4 20-1/4 14-1/4 18-1/4 25 1/4 SATE G----—DRAIJNS I I . F 1.1/2 Return At, 1.1/2 —__1•'111/16 Return Air 3/4 FRONT VIEW SIDE VIEW CB19 DOWN-FLO POSITION i 1.1/2 Model No. C819-21 & 26 CB19-31 & 41 C819-51 & 65 A 48 51 60 B 18-1/4 21.1/2 23.1/4 C 23-1/4 23-1/4 25-1/4 D 18 18 20 E 15-7/8 19-1/8 20-7/8 F 21-7/16 21-7/16 23-7/16 G 15 18-1/4 20 H 9-1/8 10-3/4 11-5/8 1 8-5/8 10-3/16. 11-5/8 K 8-118 4-1/4 10 L 7-5/8 9-1/4 10-1/8 M 18-1/2 22-5/16 25-3/4 -30h— NOTE — When unit with optional electric heat is installed on a combustible floor, an RETURN additive base is required. Base is op - AIR tional and must be ordered extra. G OPENING 3/4 1-1/16 When using additive base make open - F ing in floor 2-3/8 inches larger (side to side) and 2-1/2 inches larger (front to rear) than unit supply air opening. TOP VIEW � c AIR LIQUID LINE NI 'rJ-) .44-2 r t14 a — r ' FLOW —VAPOR `YYL LINE C [�J ` J CONDENSATE —' — DRAINS r' — —1 3 L♦ A I I I OPTIONAL NI I j i ILOWER`1 I ELECTRIC NEAT i i BLOWER I \` / (Field Installedl 'LII ' r I I I -.. , I � I I i---- — �--- -- ELECTRICAL I I _—L--__—L-- INLETS mml (Both Sides) 6/8 D ---1 1.1/16 Supply Air SIDE VIEW 1 Is E -- �i I+ /16 Supply Air 1.1/16 FRONT VIEW 1� 30.- 1-1/16 1-1116 19-1/2 SUPPLY AIR OPENING 1-1116 OUTLET VIEW DIMENSIONS (inches) B19-51 & 65 BLOWER SECTION OPTIONAL ELECTRIC HEAT (Field Installed) ELECTRICAL INLET ITop and Bottom) TOP VIEW 5/8 ...1 33 ♦ 0 i AIR 21.5/8 BLOWER FLOW I I SIDE VIEW \ 30 15/16 1.1/16 1 1 5/8 -*--28-5/16 19.3/4 R A RRN OPENING 15/16 INLET VIEW CH19-51 & 65 COIL SECTION 5/8 30-0-300-11/2- 1.3I /$ 2.1/8 I 1.1/230 1-1/16 3 13.5/8 1-1/16 2 ♦ �! �4'). 1-1/16 —26-15/16 I � AIR -010 28-1/4- 21-5/8 9-12. 19-1/2 AIR OUTLET OPENING r� `LIQUID 18-5/8 AIR INLET 4 FLOW OPENING 10-15/16 LINE 1'1/16 VAPOR 2.1/8 1.318 \ CONDENSATE 1.1/2 LINE 113/8 3 DRAINS DRAIN OUTLET VIEW SIDE VIEW PAN INLET VIER CBH19-51 & 65 HORIZONTAL MODELS AIR i' i j BLOWER i j 0 0 21-5/8 FLOW r--------- i 6; i 1 i r --- — —Q BLOWER I COIL 33 SECTION 30 112 SECTION 5/8 63.1/2 SIDE VIEW NOTE — Unita are shipped with left hand air die - unit over For right hand ak deposition turn unit over lend for end( and reposition toll. ! \� -.30i - 11/16 c c EHB-SW HP19 SERIES HEAT PUMP OUTDOOR UNITS RFCIIIT'Kor EXPANSION VALVE SYSTEM *18,900 to 61,000 Btuh Cooling Capacity *19,100 to 59,000 Btuh Heating Capacity *ARI Standard 240 Certified Ratings The Lennox HP19 series heat pump outdoor units consist of seven models ranging from 1-1/2 thru 5 tons. Energy efficient outdoor units have SEER'S of up to 12.00 with a cooling capacity range of 18,900 to 61,000 Stun and COP ratings of up to 3.46 with heating capacities of 19,100 to 59,000 Btuh. The units are designed for applications with remotely located indoor blower - coil units or indoor add-on coils in Fuelmaster + installations. The outdoor units are equally suited for installation on a slab at grade level or on a roof- top. A variety of matching up-flo, down-flo and horizontal blower powered l indoor units, with optional supplemental electric heat, provide selective sizing and installation versatility. For Fuelmaster + applications and com- plete data on indoor units see individual bulletins indexed in this tab sec- tion. Outdoor units are test operated at the factory to insure proper operation and are shipped ready for installation. Installer has only to locate unit and make refrigerant line and electrical connections to complete installation. Refrigerant Control Choice — A choice of refrigerant flow controls is available. Use an RFCIUT•M' refrigerant metering orifice for an economical installation restricted to specific indoor coil units. An alternate choice is to select an optional check and expansion valve kit to give a larger selection of indoor coils to select from. RFCIII SYSTEMS DISTRIBUTOR RFCIII METERING ORIFICE DISTRIBUTOR C�CABINET CONNECTOR LIQUID STRAINER IS PROVIDED LINE IN CONNECTOR TO PROTECT ORIFICE FROM FOREIGN MATTER Refrigerant Flow Control 1H — HP19 units are applicable to Lennox RFCIII systems when matched with the CB19 and CBH 19 blower -coil units only. RFCIII (Refrigerant Flow Control) is a very accurate means of metering refrigerant in a system. Refrigerant metering control is accomplished by the exact sizing of a refrigerant metering orifice located in the distributor of the CB19/CBH19 coils. The distributor Is equipped with a flare fitting connector located external to the cabinet for easy connection of the liquid line. See sketch. The design of the bullet-shaped metering orifice allows for reverse flow during the heat*1g cycle. As the refrigerant flows in the C reverse direction the orifice movesback in the free flow position, eliminating the need for a check valve and related piping in the system. The whole principle of the RFCIII system involves the matching of the indoor coil and the proper sizing of the metering orifice. The RFCIII system equalizes pressures instantly after the compressor stops. It therefore starts unloaded eliminating the need for any extra controls. ` Expansion Valve Systems — For maximum seasonal efficiency use an (` expansion valve matched to a chosen indoor unit. Check and expansion valve kits are available and must be ordered extra. Kits field install on the indoor coil units..For kit requirements see ARI Ratings table. For use in expansion valve systems the C819/CBH19 indoor coils must be field altered for removal of the RFCIII refrigerant metering orifice. The orifice may be easily removed at the liquid line connection on the indoor coil. NOTE — Specifications, Ratings and Dimensions subject to change without notice. C"INVU WM PR ONLY "INVU MrM Morrn corrowrMTr +s wrm MTM +qi ENGINEERING DATA HEAT PUMPS MATCHED REMOTE SYSTEMS Page 21 September 1988 3��MpfMr 1++� L �.Vry�� • � ��o pUp�•�-�t Typical Application C 3 ARI RATINGS Outdoor HP19-211 HP19-261 HP19.311 tARI Standard 240 Ratings HP19-461 HP19463 H1319-511 HP19-513 HP19-651 HP19-653 Outdoor Net face area (sq. h.)Inner jOuter Coil Unit 11.83 High Low 18.22 21.64 23.92 Total 23.01 Coil Total 3/8 3/8 *Check Model No. Cool. Temp. Temp. Total SEER EER Unit 2 High Unit Low Indoor and *ARI Std. Cap. Htg. Htg. Unit Ietuh/ (Btuh/ High Hig * HSPF Temp. Low Temp , Unit Expansion 270 SRN Ietuh) Cap. Cap. Cooling Watt) Watt) Temp. 3 Htg. Temp. Htg. Outdoor Valve (bels) 1/6 IBtuhl IBtuhl Watts 1/4 1/4 Htg. Cfm C.O.P. Htg. C.O.P. 3350 Kit 3900 4100 Rpm 840 840 1 820 Watts 820 860 Watts Watts 185 185 18,900 19,100 11,000 1910 11.00 9.90 1790 7.40 3.12 1480 2.16 CB18-31, CBS18-31 LB-34792BE AP19-211 • 19,600 19,200 10,900 1825 10.80 10.70 1670 7.80 3.36 1380 2.30 CB19-21, CBH19-21 ttRFCIII (7.2) 1-1/8 Shipping weight (lbs.) 201 204 261 267 301 321 359 Number of packages 1 1 CB19-21, CBH19-21 L 1 1 19,600 19,200 10,900 1825 12.00 10.70 1670 7.80 3.36 1380 2.30 LB -347928E CB19-26, CBH19.26 25,000 24,600 13,800 2480 10.75 10.10 1 2260 7.40 1 3.18 1780 2.26 CB18-31, CBS18-31 LB-34792BE HP19-261 25,200 25,000 14,000 2455 10.60 10.30 2180 7.80 3.36 1720 2.36 CB19-26, CBH19-26 ttRFCNI (7.4) 25,200 25,000 14,000 2455 11.30 10.30 2180 7.80 3.36 1720 2.36 CB19-26, CBH19-26 26,000 25,200 13,900 2470 11.55 10.50 2140 7.90 3.46 1690 2.38 CB19-31, CBH19-31 LB -347928E 30,000 28,800 16,800 2930 11.00 10.20 2760 7.35 3.04 2200 2.24 CB18-41, CBS18-41 LB-34792BG HP19-311 31,000 30,000 17,100 2885 10.60 10.70 2610 7.90 3.36 2100 2.38 CB19-31, CBH19-31 ttRFCM (7.4) 31,000 30,000 17,100 2885 11.80 10.70 2610 7.90 3.36 2100 2.38 C819-31, CBH19-31 31,000 30,200 17,200 2910 11.60 10.60 2640 7.85 3.36 2130 2.38 CB19-41, CBH19-41 LB-34792BG 34,800 34,600 20,400 3570 10.40 9.70 3320 7.50 3.06 2590 2.30 C818-41, CBS18-41 35,400 35,400 20,400 3490 10.90 10.20 3140 8.00 3.30 2490 2.40 CB19-31, CBH19-31 LB-34792BG HP19 411 HP19-413 36,000 35,800 20,600 3520 10.35 10.20 3140 8.10 3.34 2490 2.42 C819-41, CBH19-41 ttRFCIII (7.4) 36,000 35,800 20,600 3520 11.00 10.20 3140 8,10 3.34 2490 2.42 CB19-41, CBH19-41 36,200 35,400 20,600 3660 10.60 9.90 3320 7.65 1 3.12 2620 2.30 CB18-51, CBS18-51 LB-34792BG 37,200 36,200 20,800 3600 11.15 10.30 3170 8.05 3.36 2540 2 .40 C619-51, CBH19-51 HP19-461 41,500 42,500 24,200 4260 10.85 9.70 3840 7.90 3.24 2940 2.42 CB18-51, CBS18-51 LB-34792BG HP19-463 43,000 43,000 24,400 4200 10.50 10.20 3680 8,30 3.42 2830 2.52 CB19-51, CBH19-51 ttRFCHI (7.4) 43,000 43,000 24,400 4200 11.50 10.20 3660 8.30 3.42 2830 2.52 CB19-51, CBH19-51 LB-34792BG 46,000 46,500 26,000 4910 10.20 9.40 4350 7.20 3.14 3390 2.24 CB18-65, CBS18-65 LB-34792BF HP19-511 HP19-513 47 500 48,000 27,600 4770 10.15 9.90 4240 8.00 3.32 3340 2.42 CB19-51, CBH19-51 ttRFCIII 11 47,500 48,000 27,600 4770 11.00 9.90 4240 8,00 3.32 3340 2.42 C819-51, CBH19-51 49,500 48,000 27,600 4850 11.40 10.20 4260 8,00 3.30 3350 2.42 C819-65, CBH19-65 LB -347928F HP19-651 56,500 59,000 33,200 6370 9.65 8.90 5700 7,25 3.04 4320 2.26 CB18-65, CBS18-65 HP19-653 LB-34792BH (7,8) 61,000 59,000 33,800 6370 10.50 9.60 5360 7.65 3.22 4160 2.38 CB19-65, CBH19-65 • Sound Rating Number in accordance with ARI Standard 270. iRated in accordance with ARI 240 and DOE; with 25 ft. of connecting refrigerant lines. Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air. -Heating Seasonal Performance Factor. ttRFC metering orifice furnished with indoor coil unit. *Must be ordered extra for field installation. SPECIFICATIONS Model No. HP19-211 HP19-261 HP19.311 HP19-411 HP19-413 HP19-461 HP19463 H1319-511 HP19-513 HP19-651 HP19-653 Outdoor Net face area (sq. h.)Inner jOuter Coil 11.83 11.83 15.94 15.94 18.22 21.64 23.92 coil 8.57 8.57 15.34 15.34 17.53 20.81 23.01 Coil Tube diameter (in.) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 No. of rows 1.75 1.75 2 2 2 2 2 Fins per inch 18 18 18 18 18 18 20 Diameter (in.) 20 20 24 24 24 24 24 No. of blades 4 4 3 3 3 4 4 Outdoor Motor hp 1/6 1/6 1/6 1/6 1/6 1/4 1/4 Fan Cfm 2300 2300 3350 3350 3400 3900 4100 Rpm 840 840 1 820 820 820 860 815 Watts 185 185 210 210 200 290 350 Refrigerant -22 (charge furnished) 6 lbs. 5 oz. 6 lbs. 14 oz. 9 lbs. 5 oz. 11 lbs. 3 oz. 12 lbs. 10 oz. 12 lbs. 13 oz. 16 lbs. 4 oz. Liquid line connection (sweat) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Vapor line connection (sweat) 5/8 5/8 3/4 1 /4 7/8 7/8 1-1/8 Shipping weight (lbs.) 201 204 261 267 301 321 359 Number of packages 1 1 1 i L 1 1 1 1 1 M ELECTRICAL DATA Model Number HP19-211 HP19-261 HP19-311 HP19-411 HP19-413 HP19-461 HP19-463 Line voltage data - 60 hz 208/230v 60hz/1ph 208/230v 60hz/1ph 208/230v 60hz/lph 208/230v 60hz/lph 208/230v 60hz/3ph 208/230v 60hz/1ph •. 208/230v 60hz/3ph Compressor Rated load amps 9.7 12.1 14.2 15.6 10.8 18.3 11.7 Power factor .98 .98 .98 .98 - .88 .98 .88 Locked rotor amps 54.0 57.0 66.0 75.8 65.0 97.6 73.7 Outdoor Coil Fan Motor Full load amps 1.1 1.1 1.1 1.1 1.1 1.1 1.1 Locked rotor amps 2.0 2.0 2.0 2.0 2.0 2.0 2.0 Recommended maximum fuse or circuit breaker size (amps) 20 25 30 35 25 40 25 'Minimum circuit ampacity 11 13.3 16.3 18.9 20.6 14.6 24.0 15.8 'Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements. NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. ELECTRICAL DATA Model Number HP19-511 HP19-513 r----------1 HP19-651 r'-------� 8 r ---.-_.-_-_-I HP19-653 Line voltage data - 60 hz 208/230v 60hz/1ph 208/230v 60hz/3ph i SWITCH i ••460v 60hz/3ph 208/230v 60hz/1ph 208/230v 60hz/3ph :(BY OTHERS), I AUXILIARY ••460v 60hz/3ph Compressor Rated load amps 20.4 13.3 6.2 27.6 17.7 E 9.4 Power factor .98 .88 .88 .98 .88 .88 Locked rotor amps 107.4 74.0 37.0 135.0. 105.0 55.0 Outdoor Coil Fan Motor Full load amps 2.2 2.2 1.1 1.7 1.7 1.1 Locked rotor amps 4.5 4.5 2.0 3.0 3.0 2.0 Recommended maximum fuse or circuit breaker size (amps) 45 30 15 60 40 20 .Minimum circuit ampacity 27.7 18.9 8.9 36.2 23.9 12.9 'Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements. NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. --Extremes of operating range are plus and minus 10% of line voltage. FIELD WIRING r------� n IDISCONNECTI `=( OUTDOOR ' SWITCH UNIT j (BY OTHERS) - - - - - - - G LENNOX INDOOR UNIT A - Two or Three wire power (see Electrical Table) B - Two or Three wire power (size to heater capacity) C - Two wire power (size to indoor coil blower motor) D - Two wire low voltage (18 ga. minimum) E - Eight wire low voltage (18 ga. minimum) with Electric Heat - Ten wire low voltage with Optional Outdoor Thermostat F - Four wire low voltage (18 ga. minimum) G - Three wire low voltage (18 ga. minimum) Field wiring not furnished - NOTE - All wiring to conform to NEC and local electrical codes. -22b- 2� r----------1 r--------1 r'-------� 8 r ---.-_.-_-_-I ' LENNOX I -DISCONNECT' IDISCONNECTI I LENNOX ' j THERMOSTAT I i SWITCH i SWITCH OPTIONAL I (Optional) I )IBY OTHERS): :(BY OTHERS), I AUXILIARY L--- -�-� 6-.- __-j L-------- ELECTRIC HEATER UNIT E A i OPTIONAL ; i OUTDOOR I THERMOSTAT I 6---- --j F D - r------� n IDISCONNECTI `=( OUTDOOR ' SWITCH UNIT j (BY OTHERS) - - - - - - - G LENNOX INDOOR UNIT A - Two or Three wire power (see Electrical Table) B - Two or Three wire power (size to heater capacity) C - Two wire power (size to indoor coil blower motor) D - Two wire low voltage (18 ga. minimum) E - Eight wire low voltage (18 ga. minimum) with Electric Heat - Ten wire low voltage with Optional Outdoor Thermostat F - Four wire low voltage (18 ga. minimum) G - Three wire low voltage (18 ga. minimum) Field wiring not furnished - NOTE - All wiring to conform to NEC and local electrical codes. -22b- 2� RATINGS NOTE - To determine Sensible Capacity, Leaving Wet Bulb and Dry Bulb temperatures not shown in the tables, see Miscellaneous Engineering Data section, page 9. HP19-511-513 COOLING CAPACITY WITH CB18-65 OR CBS18-65 INDOOR COIL UNIT NOTE - All values are gross capacities and do not include indoor coil blower motor heat deduction. HP19-511-513 COOLING CAPACITY WITH CB19-65 OR CBH19-65 INDOOR COIL UNIT Compressor Motor Watts Input Total Output (Btuh) 65 Air Temperature Entering Outdoor Coil (°F) 58,800 60 Outdoor Air Temperature EnterinA Outdoor Coil °F 65 45 1 25 5 5 -15 8595 (cfm) TotHtg. jCap.81(BtuM Comp. Mtr. Total Htg. 95 Total Htg. Comp. Mtr. Total Htg. 105 Total Htg. Comp. Mtr. 115 115 Input (W) Enter. Total Air Total Comp. Sensible Total Comp. Sensible Total Comp. Sensible Total Comp. Sensible Wet Bulb Vol. Cool Motor To Total Cool Motor To Total Cool Motor To Total Cool Motor To Total (°F) (cfm) Cap. Watts Ratio Cap. Watts Cap. Watts Ratio lb Cap. Watts Ratio S o Cap. Watts Ratio S/o (Stuh) Input D b Bulb (OF) (Btuh) Input (O D Bulb (F (Stuh) Input D Bulb F (Btuh) Input D -751-80 Bulb F Bulb (OF) 75 80 85 85 75 BO 85 75 i 8078s 75 80 85 75 BO 85 85 75 1400 1 46.900 3560 .74 .89 1.00 44 300 3800 .76 .91 1.00 41.700 4090 .78 .94 1.00 38,800 4440 .81 .97 1.00 63 1600 48,400 3590 .77 .92 1.00 45,600 3840 .79 .95 1.00 42.800 4140 .82 .98 1.00 40.100 4510 .85 1.00 1.00 42,600 1800 49 400 3620 .80 .96 1.00 46.7 3870 .83 .99 1.00 44 100 4180 .85 1.00 1.00 41 500 4580 .89 1.00 1.00 1.00 1.00 44.000 to MA 'A n7 1.00 1.00 1400 2 3 9 3 .71 10 . 1 90 41 00 .59 i. 3 .87 47,200 8 67 1600 51 700 3660 .60 .75 .89 48 800 3930 .61 .77 .91 45 800 4250 .63 .79 .95 42 700 4640 .64 .82 .98 4350 1800 52 900 3680 .62 .78 .93 49 900 3960 .63 .80 .96 46 800 4290 .65 .83 .98 43 400 4690 .67 .86 1.00 49,6W 4390 51600 .82 .99 45 900 1820 .69 .86 1.00 1 432-0 5 W . 1 IF 71 1600 55,100 3720 .45 .58 .72 52.100 4010 .45 .60 .74 48 900 4370 .46 .61 .76 45.500 1 4790 .46 .63 .79 4090 1800 55 B00 1 3730 1 .45 1 .651. .75 1153 200 1 4040 1 .46 1 .62 1 .77 1 49 900 1 4400 .46 .63 .80 46 300 1 4830 .47. .66 1 .83 NOTE - All values are gross capacities and do not include indoor coil blower motor heat deduction. HP19-511-513 COOLING CAPACITY WITH CB19-65 OR CBH19-65 INDOOR COIL UNIT NOTE - All values are gross capacities and do not include indoor coil blower motor heat deduction. HP19-511-513 HEATING CAPACITY WITH CB18-65 OR CBS18-65 INDOOR COIL UNIT Indoor Coil Compressor Motor Watts Input Total Output (Btuh) 65 Air Temperature Entering Outdoor Coil (°F) 58,800 60 Outdoor Air Temperature Enterina Outdoor Coil °F 65 45 1 25 5 5 -15 86 (cfm) TotHtg. jCap.81(BtuM Comp. Mtr. Total Htg. 95 Total Htg. Comp. Mtr. Total Htg. 105 Total Htg. Comp. Mtr. 70°F db 115 Input (W) Cap. (Btuh) Enter. Total Air Total Comp. Sensible Total Comp. Sensible Total Comp. Sensible Total Comp. Sensible Wet Bulb Vol. Cool Motor To Total Cool Motor To Total Cool Motor To Total Cool Motor To Total (OF) (cfm) Cap. Watts Ratio IS/T Ca Watts Ratio IS/TI Ca Watts Ratio S/TI Cap. Watts Ratio IS/T) (Stuh) Input Dr Bulb °F) (Btuh) Input D Bulb (°F) (Stuh) Input Dr Bulb (°F) (Btuh) Input D Bulb (OF) 75 80 85 75 i 8078s 75 BO 85 75 80 85 1400 50,000 3630 .74 .88 1.00 47,200 3880 .76 I.90 1.00 144,200 4190 8 .93 1.00 41,200 4570 .80 .97 1.00 63 1600 51.200 3650 .77 .92 1.00 48.600, 3920 .79 .95 1.00 45 800 4240 81 .98 1.00 42,600 4640 .84 1.00 1.00 1800 52.700 3680 .80 .96 1.00 149.700 3950 .82 1.90 1.00 146,900 4290 .85 1.00 1.00 44.000 4710 .88 1.00 1.00 1400 2 3 9 .58 .71 .84 50 3 97 .59 i. 3 .87 47,200 4300 0 . 5 .90 9 471 .62 .78 .93 67 1600 54,900 3720 .60 .74 .88 51.800 4010 .61 .76 .91 48,500 4350 .62 .79 .94 45 000 4770 .64 .82 .98 1800 56 300 3750 :62 .77 .92 53 000 4040 .63 1.79 .95 49,6W 4390 .64 .82 .99 45 900 1820 .67 .86 1.00 1 W .44 i .5 0 50 441 .45 . 9 . U 5 71 1600 57 900 3760 .44 .58 .72 54 700 4090 .45 .59 .74 51,300 4460 .45 .61 .76 47 700 4900 .46 .63 .79 1800 59 300 3810 .45 .60 .75 55,900 4120 .46 !.6' .77 52,400 4500 .46 1 .63 .80 48 600 4950 NOTE - All values are gross capacities and do not include indoor coil blower motor heat deduction. HP19-511-513 HEATING CAPACITY WITH CB18-65 OR CBS18-65 INDOOR COIL UNIT Indoor Coil Compressor Motor Watts Input Total Output (Btuh) 65 Air Temperature Entering Outdoor Coil (°F) 58,800 60 3790 Air Volume 65 45 1 25 5 5 -15 (cfm) (cfm) TotHtg. jCap.81(BtuM Comp. Mtr. Total Htg. Comp. Mtr. Total Htg. Comp. Mtr. Total Htg. Comp. Mtr. Total Htg. Comp. Mtr. 70°F db Input (W) Input (W) Cap. (Btuh) Input (WI Cap. (Btuh) Input (W) Cap. (Stuh) Input (W) Cap. IBtuh) Input (W) 1400 1 57,900 3995 43,700 3395 29.200 2820 19,200 2135 9400 1615 1600 58,800 3950 44,600 3350 30.100 2775 1 20 100 2090 10,300 1570 1800 I 1 59,900 3920 45,700 3320 3'.200 2745 21 200 2060 -11,400 1540 NOTE - Heating capacities include the effect of defrost cycles in the temperature range where they occur. HP19-511-513 HEATING CAPACITY WITH CB19-65 OR CBH19-65 INDOOR COIL UNIT Indoor Coil Compressor Motor Watts Input Total Output (Btuh) 65 Air Temperature Entering Outdoor Coil (°F) 58,800 60 3790 Air Volume 65 45 25 5 3465 -15 (cfm) Total Htg. Comp. Mtr. Total Htg. Comp. Mtr. Total Htg. Comp. Mtr. ICap. Total Htg. Comp. Mtr. Total Htg. Comp. Mtr. 70°F db Cap. (Btuh) Input (W) Cap. IBtuh) Input (W) (Btuh) Input IWI Cap. (Btuh) Input (W) Cap. (Btuh) Input (W) 27,500 59,200 4010 45,100 3385 30.600 2750 20,300 2230 9900 1685 A1400 1600 60,200 3965 46 100 3340 31.6W 2705 21,300 2185 10,900 1640 1800 61 300 3935 47 200 3310 3-,700 2675 1 22,400 1 2155 1 12,000 1610 NOTE - Heating capacities include the effect of defrost cycles in the temperature range where they occur. HP19-511-513 HEATING PERFORMANCE HP19-511-513 HEATING PERFORMANCE at 1600 cfm Indoor Coil Air Volume (CB18-65 or CBS18-65) at 1600 cfm Indoor Coil Air Volume (CB19-65 or CBH19-65) *Outdoor Temp. (Degree F) Compressor Motor Watts Input Total Output (Btuh) 65 3950 58,800 60 3790 55,400 55 3625 52,000 50 3465 48,6 47- 3370 46,500 45 350 44 600 40 3295 39 1W 35 3240 35,200 30 1 3005 32,600 25 1 2775 30,100 20 2540 27,500 17 2400 26 000 15 2350 25.000 10 2220 22.600 5 2090 20 100 0 1960 17 600 -5 1830 15 200 - 10 1700 12 700 - 15 1570 10.300 -20-1 1440 1 7800 *Outdoor Temp. (Degree F) Compressor Motor Watts Input Total Output (Btuh) 65 3965 60 200 60 3815 56,800 5 3660 53,400 50 3510 50 47 3420 48&000 45 3340 2W 100 40 3150 41,400 35 2955 36,600 30 1 2830 34,100 25 1 2705 31,600 20 1 2585 29,100 17 2510 27,600 15 2455 26.600 10 2320 23.900 5 2185 21,300 0 2050 18,700 - 5 1915 16.100 - 10 1775 13.500 - 15 1640 10,900 -20 505 83 'Outdoor temperature at 70% relative humidity. Indoor temperature at 70°F. 'Outdoor temperature at 70% relative humidity. Indoor temperature at 70°F. -22P-