Loading...
BMCH2015-0206J�-7125 T4tit Q�i a""""� LSRECTJ.QNS&_( VOICE (760) 78-495 CALLE TANIPICO D 11I 1 8F/ i 60 -7011 LA QUINTA, CALIFORNIA 92253 ( )7COMMUNITY DEVELOPMENT DEPARTMENT 60 77 -7153 BUILDING PERMIT CITYOFLAQUINTA COMMUNITY DEVELOPMENT DEPARTMENT a e: /2015 Application Number: BMCH2O15-0206 Owner: Property Address: 54540 AVENIDA CARRANZA DAVID BROWN APN: 774275025 54540 AVENIDA CARRANZA Application Description: BROWN / CHANGE OUT (1)13SEER/78AFUE PACKAGE SYSTEM LA QUINTA, CA 92253 Property Zoning: Application Valuation: $12,700.00 Applicant: BREEZE AIR CONDITIONING INC 75-145 ST CHARLES PLACE PALM DESERT, CA 92211 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License CI ss: O License No.: 416394 Date: / �/ Contractor: OWNER -BUILDER D RATION I hereby affirm under penalty of perjury tha exempt from the Contractor's State License Law for the following reason (Sec. 031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Addre: Contractor: BREEZE AIR CONDITIONING INC 75-145 ST CHARLES PLACE PALM DESERT, CA 92211 (760)346-0855 Llc. No.: 416394 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compe n, as provided for by Section 3700 of the Labor Code, for the performance I e w which this permit is issued. a i_ maintain workers' compensation insurance, as required by do 0 of the Labor Code, for the performance of the work for which this permit ed. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ _ I certify that in the performance of the work for which this permit is Issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of r Code, I shall forthwith complyt7lw ions. /5 Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' PENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and. state laws relating to building construction, and hereby authorize representatives of this ' o enter up n the above- mentioned ro rty f ins ection purposes. Date: ( / Signature (Applicant or Agent): FINANCIAL . 1 DESCRIPTION ACCOUNT QTY' AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $1.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE HVAC CHANGEOUT - PACKAGED UNIT 101-0000-42402 0 $36.26 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT. QTY AMOUNT PAID PAID DATE HVAC CHANGEOUT - PACKAGED UNIT PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forCHANGEOUT: $60.43 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for PERMIT ISSUANCE: $91.85 $0.00 • 1 • 00 Description: BROWN / CHANGE OUT (1)13SEER/78AFUE PACKAGE SYSTEM Type: MECHANICAL Subtype: Status: APPROVED Applied: 6/16/2015 SKH Approved: 6/16/2015 SKH Parcel No: 774275025 Site Address: 54540 AVENIDA CARRANZA LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA AT VALE LA QUINTA Block: 307 Lot: 24 Issued: UNIT 28 Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $12,700.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: HVAC CHANGE OUT - 13SEER/78AFUE PACKAGE SYSTEM [2013 ENERGY] CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. 2013 CALIFORNIA BUILDING CODES. CHRONOLOGY CONDITIONS CONTACTS NAME TYPE' NAME ADDRES51 CITY STATE ZIP PHONE FAX EMAIL APPLICANT BREEZE AIR CONDITIONING INC 75-145 ST CHARLES PLACE PALM DESERT CA 92211 CONTRACTOR BREEZE AIR CONDITIONING INC 75-145 ST CHARLES PLACE PALM DESERT CA 92211 OWNER DAVID BROWN 54540 AVENIDA CARRANZA LA QUINTA CA 92253 Printed: Tuesday, June 16, 2015 3:03:29 PM 1 of 2 CJ?W SYSTEMS INSPECTIONS - ` SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED DATE DATE RESULT REMARKS NOTES MECHANICAL FINAL" BLD _ CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID'DATE RECEIPT # CHECK # METHOD PAID BY+ BY BSAS S81473 FEE 101-0000-20306 0 $1.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $1.00 $0.00 BSA: HVAC CHANGEOUT - 101-0000-42402 0 $36.26 $0.00 PACKAGED UNIT HVAC CHANGEOUT - 101-0000-42600 0 $24.17 $0.00 PACKAGED UNIT PC Total Paid forCHANGEOUT: $60.43 $0.00 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:•• INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED DATE DATE RESULT REMARKS NOTES MECHANICAL FINAL" BLD Printed: Tuesday, June 16, 2015 3:03:29 PM 2 of 2 RWYSTEMS Jun 16 2015 08:28PM AHP Testing 760-772-4656 page 1 of La Quinti BAft ar Safety Divhforr P.O. Box 1544,-78.495 Cade Tampico La.QtBnta, CA 92253 -:(760) 777-7012 Building Permit Applicationand Tracking Sheet it [Mn 02, eat.Aadl'ess:54-540 Avenida Carranza oamea'sNsme:. arriie & Davi Brown A. P: Nun*cr • Addles: 54-540 Avenida Carranza Legal oewiptim: City, ST, Zi.: La Quinta, CA 92253 Contractor: Breeze Air Conditioning; Inc. Td,,,&?& Address 75-145 St. Charles Place Projectnescriptiat: Replacing existing heat pump city, ST, zippalm Desert -CA 92211 with 5 -ton heat pump, .15 -seer, variable speed Tetephem:760-346-0855 no duct work changed Stan Lic. iF 41639 City Lic, M . Address, - City, ST. Zip: Telephone:ALTConstruction Type:. Oxupancy State Lie. #l: Project b'pe (circle one): New Add'a Ahw RePair Demo Name ofCoaotatPerson:Robert Bachus S4, FL: 1872 0 stmies: AUnitt: 12700 Telephone ii of ContW Potsoa: 7 -851-864Esdmttted Value of Ptojeok ' APPLICANT: DO NOT WRM BELOW THtS LINE M S' a61ttal Req9d 2,ee'd TRACKMG PERtdti'FEES Plan Sets Plan Check sabkaftaed Item Amoaat Structural Cates. Revtewed, ready for correcuoat Pba Cb tCk D epottt . Tans Cala. ce Called Contact Persoa Flan. Cheek Balan, Me 24 Caks. Plana *kedap Coastracdon Hood plata piss Plans tYsnb+nflltd • . Meehaikst Gi"ug plan r Review, ruAy for correctinafawe Efe cUlial 6abeoabat:tor List Called Coobet lunt Person Pblag Gnat Dead Puna picked op SALL H.O.A. Approval Plan resabrntfted Gradfag IN HOLM- ''*'Bevfew, ready for tarreetioulfaeae Dewdaper Impact Fee Pluming Approval • called Contact Person A.I.P.P. Pub. TVb. Appr Date of pertaft )me stbool Fees Total Permit Fees CERTIFICATE OF COMPLIANCE Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) Project Name: S4-540 Avenida Carranza ( Date Prepared: CF1R-ALT 02-E (Page i of 3 ) 2015-06-16 A. General Information CFIR-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented; use one CF1R-ALT 02 document for each dwelling unit. 01 Project Name 54-540 Avenida Carranza 02 Date Prepared 2015-06-16 03 Project Location 54-540 Avenida Carranza 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name 54-540 Avenida Carranza 07 Zip Code 92253 08 Dwelling Unit Conditioned 1872 Installing Installing Installing Floor Area (ft2) Location or Area by this SC ducted containing system Number of space conditioning entirely new 09 Climate Zone 15 10 (SC) systems in this dwelling 1 component? components? feet of ducts? duct system? unit. Alteration Type B. Space Conditioning (SC) System Information 01 02 03 04 05 06 07 08 09 10 Is the SC Installing a SC System SC System CFA served system a refrigerant Installing new SC Installing Installing Installing Identification or Location or Area by this SC ducted containing system more than 40 entirely new entirely new Name Served System (ft2) system? component? components? feet of ducts? duct system? SC system? Alteration Type Altered space System 1 Location 1 1872 Yes Yes Yes No No No conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Sect ion150.2(b)1 Diib) This section does not apply to this project. Registration Number: 215-A0160689A-000000000-0000 Registration Date/Time: 2015-06-16 11:53:13 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-03-31 Repan Generated: 2015-06-16 11:47:48 CrhPmn %lamimv n SSSGnn CERTIFICATE OF COMPLIANCE CFIR-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 2 of 3 ) D. Altered Space Conditioning System (Sections 150.2(b)IE and F) 01 02 03 04 05 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R -Value . All new All new This field or This field or System 1 Central heating AFUE 0.78 Centra! cooling SEER 13 Setback section is not section is not packaged HP components ackaed AC pg components applicable applicable geauimd Documentation: CF2R-MCH-01-E - Space Conditioning Systems Ducts and Fans -Duct insulation requirement for new plenums: R6. CF2R-MCH-20-H & CF3R-MCH-20-H — Duct Leakage testing required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length Is replaced. -Leakage rate compliance: 515%, or <_ 10% leakage to outside, or seal all accessible leaks. CF2R-MCH-25-H & CF3R-MCH-25-H Refrigerant Charge Verification required when refrigerant containing components are Installed or altered (applicable in CZ 2, 8-15). CF2RCF3R-MCH-23 & CF3R-MCH-23 Air Flow 2 300 CFM/ton required when MCH -25 Is required. Exceptions: -Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Dud Leakage Testing requirements. -Heating-only systems and Air Handler/Fumace changes do not require verification of Air Flow MCH -23, or Refrigerant Charge MECH-25. -Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH -20 Duct Leakage Testing requirements. E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)Wlia and 150.2(b)1E, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 1S0.2(b)IC) This section does not apply to this project. Registration Number: 215-A0160689A-000000000-0000 Registration Date/Time: 2015-06-1611:53:13 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-03-31 Report Generated: 2015-06-16 11:47:48 crhpm;a vorcinn• n r,tScnn CERTIFICATE OF COMPLIANCE MR -ALT 02-E Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 3 of 3 ) Documentation Author's Declaration Statement 1.1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Bachus, Robert J� Company: Signature Date: Advancing Home Performance, Inc. 2015-06-16 11:47:41 Address: CEA/ HERS Certification Identification (if applicable): 74998 Country Club Drive, City/State/Zip: Phone: Palm Desert CA 92260 760-851-8648 Responsible Person's Declaration statement 1 certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified an this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. S. I will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permits) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Responsible Designer Signature: White, Butch Company: Date Signed: BREEZE AIR CONDITIONING INC 2015-06-16 11:53:13 Address: License: 75-14S ST CHARLES PLACE 416394 City/State/Zip: Phone: PALM DESERT CA 92211 (760) 346-0855 Digitally signed by ca/CERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-A0160689A-000000000-0000 Registration Date/Time. 2015-06-16 11:53:13 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-03-31 Report Generated: 2015-06-16 11:47:48 Cf11Gma t/. -i— n CGSCnn