05-2299 (SFD)P.O. BOX 1504f44Q VOICE (760) 777-7012
78-495 CALLE TAMPICO FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 6/13/05
Application Number: 05-00002299 Owner:
Property Address: 79859 CASTILLE DR LENNAR HOMES OF CALIFORNIA
APN: 609-380-999-25 -293234- 401 HIGHWAY 111, STE C
Application description: DWELLING - SINGLE FAMILY DETACHED QUINTA, CA
Property Zoning: LOW DENSITY RESIDENTIAL VJULj2j6200J511 QUINTA, CA 92253
Application valuation: 145328
C ntractor:
Applicant: Architect or Engineer: CIN OF 4A QUINTA L NNAR HOMES OF CALIFORNIA INC
iaot�FINANCE DEPT. 7 401 HIGHWAY 111, SUITE C
LA QUINTA, CA 92253
WCC: AON RISK SRVC
vy"2 LiC. No.: B
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License lass: License No.: B
�ate7 ntracto
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not.intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
1 _ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
1 _ 1 I am exempt under Sec. , B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the,
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
-i•
LQPER111IT
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier MWC11114500 11 / 0 1 / 0 Solicy Number 728102
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
4NG
0 of the labor Cod 1 shalt forthwith comply with those provisions.
���licant:
WARNRE TO SECURE WORK COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS 0100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Ouinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
1 certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
ofthis count to ent u�o the above-mentioned pro for inspection urposes.
fie: ature (Applicant or AgenO:
,- r
LQPERA4[T
Application Number . . . . . 05-00002299
Structure Information
Construction Type . . . . . TYPE V - NON RATED
Occupancy Type . . . . . DWELLG/LODGING/CONG <=10
Flood Zone . . . . . NON -AO FLOOD ZONE
Other struct info . . . . . CODE EDITION 2001 CRC
# BEDROOMS 5.0.0
FIRE SPRINKLERS NO
GARAGE SQ FTG 418.00
PATIO SQ FTG 45.00
NUMBER OF UNITS 1.00
1ST FLOOR SQUARE FOOTAGE 2387.00
----------------------------------------------------------------------------
Permit . . . BUILDING PERMIT
Additional desc . .
Permit Fee . . . . 800.50
Issue Date . . . .
Expiration Date . . 12/10/05
Plan Check Fee . . 520.33
Valuation . . . . 145328
Qty Unit
Charge
Per
Extension
BASE
FEE
639.50
46.00
----------------------------------------------------------------------------
3.5000
THOU BLDG
100,001-500,000
161.00
Permit .
. . MECHANICAL
Additional desc
. .
Permit Fee . .
. .
39.50
Plan Check Fee
.9.88
Issue Date ..
Valuation . . .
. 0
Expiration Date
12/10/05
Qty Unit
Charge
Per
Extension
BASE
FEE
15.00
1.00
9.0000
EA MECH
FURNACE <=100K
9.00
1.00
9.0000
EA MECH
B/C <=3HP/100K BTU
9.00
1.00
----------------------------------------------------------------------------
6.5000
EA MECH
EXHAUST HOOD
6.50
Permit . . . ELEC-NEW RESIDENTIAL
Additional desc . .
Permit Fee . . . . 106.91 Plan Check Fee .
Issue Date . . .. Valuation
Expiration Date 12/10/05
26.73
0
Qty Unit Charge Per Extension
BASE FEE 15.00
2387.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 83.55
418.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 8.36
Application Number . . . . . OS -00002299
Permit' . .
PLUMBING
Additional desc .
Permit Fee . . . .
170.25 Plan Check Fee
42.56
Issue Date . . . .
Valuation . . .
. 0
Expiration Date . .
12/10/05
Qty Unit Charge
Per
Extension
BASE FEE
15.00
17.00 6.0000
EA PLB FIXTURE
102.00
1.00 15.0000
EA PLB BUILDING SEWER
15.00
1.00 7.5000
EA PLB WATER HEATER/VENT
7.50
1.00 3.0000
EA PLB WATER INST/ALT/REP
3.00
1.00 9.0000
EA PLB LAWN SPRINKLER SYSTEM
9.00
5.00 .7500
EA PLB GAS PIPE >=5
3.75
1.00 15.0000
----------------------------------------------------------------------------
EA PLB GAS METER
15.00
Permit . . . GRADING PERMIT
Additional desc .
Permit Fee . . . .
15.00 Plan Check Fee
.00
Issue Date . . . .
Valuation . . .
. 0
Expiration Date
12/10/05
Qty Unit Charge
Per
Extension
BASE FEE
15.00
------------------------------------------ ---------------------------------
Special Notes and Comments
SFD - LOT 25. PLAN 3YR, 2387 SF. PERMIT
DOES NOT INCLUDE BLOCK WALL, POOL, SPA
OR DRIVEWAY APPROACH.
----------------------------------------------------------------------------
Other Fees . ... . .
. . . . ART IN PUBLIC PLACES -RES
.00
DIF COMMUNITY CENTERS -RES
97.00
DIF CIVIC CENTER - RES
366.00
ENERGY REVIEW FEE
52.03
DIF FIRE PROTECTION -RES
97.00
GRADING PLAN CHECK -FEE
.00
DIF LIBRARIES - RES
225.00
DIF PARK MAINT FAC - RES
5.00
DIF PARKS/REC - RES
502.00
STRONG MOTION (SMI) - RES
14.53
DIF STREET MAINT FAC -RES
15.00
DIF TRANSPORTATION - RES
1098.00
Fee summary Charged Paid Credited
---------------------------------------------------------
Due
LQPERMIT - `
Application Number
Permit Fee Total
Plan Check Total
Other Fee Total
Grand Total
LQPER ITT
05-00002299
1132.16 .00 .00 1132.16
599.50 .00 .00 599.50
2471.56 .00 .00 2471.56
4203.22 .00 .00 4203.22
DEC 15,2005 13:02 BCI*TESTING,ril 000-000-00000 Page 8
CaICERTS Certified Rating December, 15 2005
this Compliance rating is for the home located at: 79859 Castille Drive
La Quinta CA, 92253
Certificate Number: CC3-1798353624 j
Date Inspected: December, 12 2005
Ca10ERTS Rater: Rex Graham` G,
1,
CC20M77
HERS Analyst: N/A i4
Builder/ Developer: Lennar Homes R
Project: Tapestry iil Esplanade �.
Phase: Phase 11
Pian Name: Plan 3 S
Lot Number: 025
Specifics about this home:
General Information
Conditioned Floor Area: 2121 Square Feet
Conditioned Volume: 0 Cubic Feet
Front Orientation: N/A
Number of Stories: 1
Heating and Cooling Systems
Heating Equipment: Furnace: 0.8
Cooling Equipment: AC: 12
HVAC Air Distribution
Duct Location: Attic
Duct Leakage Target: 6.0
Duct Insulation R -Value: 4.2
Air Inf,ltrat/on
Blower Door Target: 120
Water Heating S stem Pro osed
TY I Size 1. Fuel I EF I Distribution
Water Heating S stem Actual
TY I Size I Fuel I EF Distribution
Testing Results
Associated to Group #13038
Ruildinn Envelnne
Surface
Area
Pro osed
Actual
I R
Value
U
Factor
R
Value
U
Factor
Windows
=TESTED
MX APPROVED AS PART OF SAMPLE GROUP (pg 1 of 1)
FIRM; BCI TESTING
ADDRESS: TT -760 COUNTRY CLUB DRIVE. SURE I
PALM DESEERT. CA. 92211
PHONE: 760-772-2954
The energy efficiency rating of this home is determined using California Homy Mrlf lh"WtVrn (C-HERSf%les. The rating considers
heating, cooling and water heating and assumes average weather, thermostat settings, and quantities of hot water for a typical household.
Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only after the features listed have
been verified and approved by the CalCERTS Certified Rater shown above. If you have a concern or complaint regarding this report of the
services used In obtaining it, you may contact: CaICERTS - Customer Service P.U. dox 6600, I-olsom, CA 95753.
Proposed
. Actual
Orientation
Area
U
U
SHGC
Value
SHGC
Value
=TESTED
MX APPROVED AS PART OF SAMPLE GROUP (pg 1 of 1)
FIRM; BCI TESTING
ADDRESS: TT -760 COUNTRY CLUB DRIVE. SURE I
PALM DESEERT. CA. 92211
PHONE: 760-772-2954
The energy efficiency rating of this home is determined using California Homy Mrlf lh"WtVrn (C-HERSf%les. The rating considers
heating, cooling and water heating and assumes average weather, thermostat settings, and quantities of hot water for a typical household.
Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only after the features listed have
been verified and approved by the CalCERTS Certified Rater shown above. If you have a concern or complaint regarding this report of the
services used In obtaining it, you may contact: CaICERTS - Customer Service P.U. dox 6600, I-olsom, CA 95753.
DEC -09-2005 FRI 08:58 AM TEAM HEATING & A/C
FAX N0, 9516943803
P. 13
MVAC INSTALLATION CERTIFICATE for Tested Duct Leakage & TXV Page 1 oft CF -6R
Site Address: 79-859 Castille Drive, La Quinta, Ca 92253 Permit Number.
Tract Number. 29323 plan # 3y Phase: 14
Lot Number. 25 Project Esplanade Builder Lennar Homes
An installation certificate is required to be posted at the building site or made avalible for all appropriate Inspections.
A1tat completion of final inspection, a copy must be provided to the Building Department (upon request) and the building
owner at occupancy, per section 10-103(b).
HVAC SYSTEMS:
Heatina Eauioment
o crency Duct Heating Heating
Equip.Name ldenticle (AFUE, etc.) Location Duct Load Capacity
T e and Model Name Systems (;—CF -IR) (attic etc.) R -value (BTU / Hr) (BTU / Hyl
Bryant —517–
Coolina Eauioment
rclency Duct Cooling Cooling
quip. GLU Garlitm Mff Name Identicle (SEER, etc.) Location Duct Load Capacity
Type and Model Number Systems (>;--CF,1 R) (attic, etc.) R -value (BTU / Hr) (BTU / Hr
Bryant ale
r, me unueraigneo, venry mar equipment osteo aoove is: t 115 the actuai equipment rnstaneo, 41 equrvarant w or more
efficient than that specified in the certificate of compliance (Form CF -1R) submitted for compliance with the Energy
Efficiency Standards for resldemlal ds, 3) I that meetp or exceeds the appropriate requirements for
manufactured devices (from the A pl i
E rd ons or art) re applicable.
6 Team Heating & Air, Ino
Signature, Date Installing Subcontractor o. Name
OR General Contractor (Co. Name) OR Owner
MINIMUM REQUIREMENTS FOR DUCT LEAKAGE COMPLIANCE CREDIT
Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage)
CFA:
System of
Indicate the'maximurn a owa le Duct Leakage and the calculation used:
0.7 x Floor Area x (0.06) for Climate Zone 8 through 15
0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16
x 400 x (Cooling Capacity in Nominal Tons) x (0.06)
21.7 x (Heating Capacity In Thousands of Output BTU per hour) x (0.06)
Measured Fan Flow
TW Pressurization Test Results
100 x Test Leakage / Fan Flow = % Leakage
Check Box for Pass or Fall (Pass;; 6% or Les6)
i YqT-24 nnee Credit was Taken for TXV
ys emof
Indicate the maximum allowable Duct Leakage and the calculation used:
0.7 x Floor Area x (0.06) for Climate Zone 6 through 15
0.5 x Floor Area x (0.09) for Climate Zones 1 through 7 & 16
400 x (Cooling Capacity in Nominal Tors) x (0.06)
21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06)
Measured Fan Flow
u Pressurization Test Resu
100 x Test Leakage / Fan Flow = % Leakage
Check Box for Pass or Fail (Pass = 6% or Less)
r—IT-24 Compliance Credit was Taken for TXV
X.06
X'06
TXV waa
rel
PAGE 1
F2001-01 (4-02) Action Now T-24CF9-RTD&TXV macro
DEC -09-2005 FRI 08;58 AM TEAM HEATING & A/C FAX N0. 9516943803 P. 14
HVAC INSTALLATION CERTIFICATE for Tested DUCt Leakage & TXV Page 2 of 2 CF -6R
site A00ress: [W-0011
Tract Number: 29323
Lot Number. 25
Project: Esplanade
System I`I of
Indreata them mum a owa to Duct Leakage and the calculation used:
0.7 x Roar Area x (0.06) for Climate Zone 8 through 15
0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16
400 x (Cooling Capacity in Nominal Tons) x (0.06)
21.7 x (Heating Capacity in Thousands of 091put BTU per hour) x (0.06)
Measured Fan Flow
u Pressurization Test Resu
100 x Teat Leakage 1 Fan Flow = % leakage
Check Box tar Pass or Fail (Pass = 6% or Less)
T-24 Compliance Credit was Taken for TXV
ya
3 -Th m of
Indicate the maximum aowa to Duct Leakage and the calculation used:
0.7 x Floor Area x (0.06) for Climate Zone 8 through 15
0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16
400 x (Cooling Capacity in Nominal Tons) x (0.06)
21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06)
Measured Fan Flaw
u Pressurization Test Resu
Its (CF191 (W 23 PAT -
100 x Test Leakage I Fan Flow - % Leakage
Check Box for Pass or Fail (Pass = 6% or Less)
qT-24 Compliance Credit was Taken for TXV
m of
Indicate them mum a�l(owable Duct Leakage and the calculation used:
0.7 x Floor Area x (0.06) for Climate Zone 8 through 15
0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16
400 x (Cooling Capacity In Nominal Tans) x (0.06)
21.7 x (Heating Capacity in Thousands of Out ut BTU per hour) x (0,05)
Measured Fan Flow
u Pressurization Test Results
100 x Test Leakage / Fan Flow = % Leakage
Check Box for Pass or Fail (Pass = 6% or Less)
T-24 Com 0
s ece Credit was Taken for TXV
ym of
Indicate the maximum a'lfowa le Duct Leakage and the calculation used:
0.7 x Floor Area x (0.06) for Climate zone 8 through 15
0.5 x Floor Area x (0,06) for Gimete Zones 1 through 7 & 16
400 x (Cooling Capacity in Nominal Tons) x (0.06)
21.7 x (Heating Capacity In Thousands of Output BTU per hour) x 0,06)
Measured Fan Flow
u Pressurii t, n Test Resu s f
100 x -rest Leakage / Fan Flow = % leakage
Check Box for Pass or Fail (Pass c 6% or Less)
[:::]T-24 Compliance Credit was Taken for TXV
X.06
X.0152
X.06
TXV wa,
TXV wa,
TXV wa,
TXV wa,
Plan: 3y Phase: 14
Builder: Lennar Homes
I, the undersigned, verify that the above diagnostic test results and the work I performed associated with the test(s) Is
in conformance with the requirements for compliance credit (The builder shall provide the HERS provider a copy of the
CF -011 signed by the builder employ o s nvacto rtifying that diagnostic testing and installation meet the
requirements for oompllan� credit.)
�1, V Team Headu & Air, Inc
es'ts'— igna um,n ngSubcontractor Name
Performed OR General Contractor (Co. Name) OR Owner
COPY -r0: Building Department
HERS Provider (if applicable)
Building Owner at Occupancy
PAGE 2
F2001.al (4-02) Action Now T-24CF6-RTD&TXV macro
m
Certificate of Insulation
a
Your home has been insulated with John Mansville Fiberglass insulation products, which are designed
CD W
for today's safety standards and tomorrow's energy requirements.
N
rl
Fiberglass is inorganic and therefore permanently noncombustible, so It does not have to be treated
Ln with fire -retardant chemicals that will likely lose their effectiveness over time. It has not been treated
mwith chemicals that can corrode wiring or metal. Fiberglass will not absorb moisture nor will it
N settle over time as may other Insulation materials.
9
Cl?
A.
ti
0
This also certifies that insulation have been professionally installed in this home to provide the
following thermal performance.
Lennar Homes
Job Name; Tapestry Q Esplanade Tract: 29323 Plan# 3YRA Phase: 94
Lot No: 25 Job Address: SFR - 79-1359 Castilla Dr La Quints, CA
Ceiling Area: R-38 batt insulation
Exterior Wall! R-13 batt insulation
Between Floors:
ti
o+
C
� Signed:
m
Garage Coiling:
With Living Above
Overhangs:
With Living Above
Interior walls:
Non -Access:
& Sloping Areas
Access Attic:
Subcontractor...0 J Insulation, Inc.
72-227 Adelald St, Thousand Palms, CA 92278
Mike Dickerson, General Manager - Palm Springs Division
R -means resistance to heat flow. The higher the R -value, the greater the insulating power.
Ask your builder for the fact sheet on R -values. Keep this certificate with your other
e
- valued papers. If you ever sell this home, this certificate should be passed on to the buyer.
PA
T I a QUINTA
DING & SA DEPARTMENT
12
}U4N
INSPEC E ; UEST LINE
Qu ��°77 7 3
CIP�girinr�i- -
Owner I'L�QIV1L+ N VV %-ALlr VM IiA
Contractor LENNA_R HOMES OF CALIFORNIA
Permit.Number 0.5-2299
POST ON JOB -IN CONSPICUOUS PLACE
INSPECTOR MUST SIGN ALL APPLICABLE SPACES
JOB ADDRESS 79-859 CASTILL'E'DRIV.E]
ISFD — LOT 25, PLAN 3YR.. PERMIT DOES NOT
INCLUDE POOL—,SPA, BLOCK WALLS OR
DRIVEWAY APPOROACH
TYPE OF INSPECTION DATE INSP.
TEMPORARY POWER
SETBACKS
U/G PLUMBING /WASTE /7 6
U/G ELECTRICAL/ GROUNDING
FOOTINGS / STEEL D �/ l �"_ —" o
+ DO NOT POUR CONCRETE UNTIL ABOVE SIGNED
ROOF NAIL / PRE -ROOF 7121le
OKAY TO WRAP 4 i
FRAMING COMBINATION
ROUGH.ELECTRIC
ROUGH PLUMBING
} ROUGH MECHANICAL
INSULATION /6 -/ •O S
COVER NO WORK UNTIL ABOVE SIGNED
INTERIOR GYP. BD. DRYWALL 1p/2 •/ 0'5 -
EXTERIOR LATH
GAS TEST (d V
SEPTIC ABANDONMENT
SEWER CONNECTION F7 1;7—/,* S
i SEPTIC / GREASE INTERCEPTOR
MASONRY INSPECTIONS
FOOTINGS / STEEL
BOND BEAM
POOL / SPA / WATER FEATURE INSPECTIONS
PRE-GUNITE / SETBACKS
U/G PLUMBING
U/G GAS
U/G ELECTRICAL
PRE -PLASTER ALARMS / BARRIERS
FINAL INSPECTIONS
TEMP. USE OF PERMANENT POWER 1113,91P5"
7'
ELECTRICAL
PLUMBING
MECHANICAL
PUBLIC WORKS DEPARTMENT / o
COMMUNITY DEVELOPMENT DEPT.
FINAL / JOB COMPLETED
ABOVE APPROVALS DO NOT INCLUDE RIGHT TO
TURN ON UTILITIES OR OCCUPY BUILDING