Loading...
05-3063 (BLCK)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description Property Zoning: Application valuation: Applicant: co,f4 Cl D< X05-00003063 79907 CASTILLE DR 609-380-999-28 -293234- WALL/FENCE LOW DENSITY RESIDENTIAL 4225 T. d -y 4 4 " BUILDING & SAFETY DEPARTMENT Architect or Engineer: VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 BUILDING PERMIT Owner: LENNAR HOMES OF CALIFORNIA 78401 HIGHWAY 111, STE C D LA QUINTA, CA LA QUINTA, CA 92253 ? JG'L ry `7 2305 Contractor: LENNAR HOMES OF CALIFORNIA INC QFLAQulfA cr WCC: AON RISK SRVC 7EPT, WC: MWC11114500 11/01/05 CSLB: 728102 09/30/06 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7 001 of Division 3 of the B siness and Professionals Code, and my License is in full force and effect. License ass: License No.: ,,16e: Contract OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 —1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.I. Lender's Name: _ Lender's Address: LQPERMIT Date: 7/21/05 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier B Policy Number - - - - - - - - - - - - - - - I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 37 0 of th Labo$ORK hall forthwith comply with those provisions. � �plicant: WARNIN : FAILURE TO SECURES' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRINALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 1$100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessatiori of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city andunty ordinances and state laws relating to building construction, and hereby authorize representatives of this c unty to nter1 up rrthe above-mentioned pro r inspection purposes. f : J'gnature (Applicant or A nt): Application Number . . . . . 05-00003063 Permit . . . WALL/FENCE PERMIT Additional desc . Permit Fee . . . . 72.00 Plan Check Fee .00 Issue Date Valuation . . . . 4225 Expiration Date 1/17/06 Qty Unit Charge Per Extension BASE FEE 45.00 3.00 9.0000 THOU BLDG 2,001-25,000 27.00 ---------------------------------------------------------------------------- Special Notes and Comments 169 L.F. 6' GARDEN BLOCK WALLS, ORCO SYSTEM. Fee summary Charged ----------------- Paid Credited Due -------------------- Permit Fee Total 72.00 ---------- .00 ---------- .00 72.00 Plan Check Total .00 .00 .00 .00 Grand Total 72.00 .00 .00 72.00 LQPERMIT DEC 15,2005 13:02 BCI*TESTING,ril 000-000-00000 Page 11 CaICERTS Certified Rating December, 15 2005 This Compliance rating is for the home located at: 79907 Castille Drive La Quinta CA, 92253 Certificate Number: CC3-1798353627 { Date Inspected: December, 12 2005 ` CaICERTS Rater: Rex Graham CC2004077 C HERS Analyst: N/A E Builder/ Developer: Lennar Homes R Project: Tapestry @ Esplanade T Phase: Phase 14 Platt Narne: Plan 1 . S Lot Number: 028 Specifics about this home: General Information Pro osed Conditioned Floor Area: 1806 Square Feet Conditioned Volume: 0 Cubic Feet Front Orientation: N/A Number of Stories: 1 Ruildina FnvPlnnP Surface Area Pro osed Actual RU Value Factor R Value U Factor Heating and Cooling Systems . Windows Heating Equipment: Furnace: 0.8 Pro sed Actual Cooling Equipment: AC, 12 Orientation Area SHGC U SHU Valu Cooling HVAC Air Distribution Duct Location: Attic Duct Leakage Target: 6.0 Duct Insulation R -Value: 4.2 Air Infiltration Slower Door Target., 120 TESTED Water Heating5 Stem Pro osed F R APPROVED AS PART OF SAMPLE GROUP (pg 1 of 1) TY Size Fuel EF Distribution FIRM: gel TESTING ADDRESS: 77-760 COUNTRY CLUB DRIVE, SUITE I Water Heating S stem Actual 12TYISzel Fuel JEFJ Distribution PALM DESSERT, CA. 92211 PHONE: 760-772-2964 Testing Results Associated to Group #13038 The energy efficiency rating of this home is determined using California Ho rating considers heating, cooling and water heating and assumes average weather, thermostat settings, and Quantities of hot water for a typical household. Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only after the features listed have been verified and approved by the CaICERTS .Certified Rater shown above. If you have a concern or complaint regarding this report of the services used In obtaining it, you may contact: CaICERTS - Customer Service P.O. Box 6600, Folsom, CA 95763, DEC -09-2005 FRI 08:59 AM TEAM HEATING & A/C FAX N0, 9516943803 P. 19 HVAC INSTALLATION CERTIFICATE for Tested Duct Leakage & TXV Page 1 oft CF -6R Site Address: 79.907 Castille Drive, La Quinta, Ca 92253 Permit Number. Tract Number. 29323 Plan * 1 Phase: 14 Lot Number: 28 Project Esplanade Builder Lennar Homes An instaltation certificate is required to be posted at the building site or made avalible for all appropriate inspections. Atter completion of final Inspection, a copy must be provided to the Building Uapartment (upon request) and the bulking owner at occupancy, per Section 10-103(b). HVAC SYSTEMS: Heatinn Fnuioment or emotency Duct Heating Heating Equip. CEC COMMName Identicle (AFUE, etc.) Location Duct Load Capacity T and Model Name System CF -1 R) (attic, eta) R -value (BTU / Hr) BTU I Hr) Bryantis Coolina Eauicment o ncy Duct cooling cooling quip. ame Identica (SEER, etc.) Location Duct Load Capacity Type and Model Number Systems (>=CF -1R) (attic, etc.) R -value (BTU / Hr) (BTU / Hr) Bryant attic r, ine unaemenea, venry alai trquiprnank mow auuve is. r) w un: natum equwmum urskaiwv, 41 04U 4illom w ui rnu10 efficient than that specified in theNngan mp' noe (Form CF -1R) submitted for compliance with the Energy Efficiency Standards for residentis bipment that meets or exceeds the appropriate requirements for manufactured devices (from the pin tions�jr art ),re eppligbEe. C `f0 Team Heating & Air, ine igna re, aInstalling Subcontractor ame OR General Contractor (Co. Name) OR Owner MINIMUM REQUIREMENTS FOR DUCT LEAKAGE COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 8% Duct Leakage) CFA: systemof Indicate the max mum allowable Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 x 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow D—u-ff Pressurizatlon Test Results 100 x Test Leakage / Fan Flow = % Leakage Check Box 1br Pass or Fall (Pass = 6% or less) rz 1T-24 Compliance Credit was Taken for TXV Tysem O of Indicate the maximum a owe le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow u Pressurization Test Resu 100 x Test Leakage I Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 60/0 or Less) [=T-24 Compliance Credit was Taken for TXV X .06 7981.1 TXV was TXV we! PAGE 1 F2001-01 (4.02) Action Now T-24CF6-RTD&TXV macro DEC -09-2005 FRI 08:59 AM TEAM HEATING & A/C FAX N0. 9516943803 P. 20 HVAC INSTALLATION CERTIFICATE for Tested Duct Leakage & TXV Page 2 of 2 CF -611 Site Address: 79-907 Castille dlive,.La 4uinta, Ca 92253 Permit Number. 0 Tract Number. 29323 Lot Number: 28 Plan #: 1 Phase: 14 Project: Esplanade Builder. Lennar Homes System of Indicate them mum a owa le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.08) for Climate Zane 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capa* in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x 0.06) Measured Fan Flow D-0 Pressurization Test Results (CFM g2o FIA) 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) I -1T-24 Compliance Credit was Taken for TXV ys am Q of Indicate the maximum a la Duct Leakage and the calculefion used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0,06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow DUE Pressurizatlon Test Results (CF 100 x Test Leakage / Fan Flow = % Leakage Check pox for Pass or Fail (Pass a 6% or Less) �T-24 Compliance Cnida was Taken for TXV of li Indicate die um a owe le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow DEW Pressurization Test 001515 (1.710 W 25 PXF- 100 x Test Leakage / Fan Flow;; % Leakage Check Box for Pass or Fall (Pass = 6% or Less) T•24 Compliance Credit was Taken for TXV of Indicate thein-ai m m a le Duct Leakage and the calculation used: 0.7 x Floor Area x (0,06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity In Nominal Tons) x (0.06) 21.7 x (Heating Capacity In Thousands of Output BTU per hour) x (0.06) Measured Fan Flow D -U3 Pressurization Test Resu s 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fall (Pass = 8% or Less) .IT -24 Compliance Credit was Taken for TXV X.06 X.06 x .06 TXV we! TXV was TXV wal TXV was I, the undersigned, verity that the above diagnostic test results and the work I performed associated with the test(s) is in conformance with the requirements for pliance credit (The builder shall provide the HERS provider a copy of the CF -6R signed by the builder employees r s ct rs ertifying that diagnostic testing and installation most the requirements for compliance credit.) J d!�)I / Team Heating & Air, Inc 7wW— na ure, mg ZiUDCDnTr8Ct0f ame Performed OR General Contractor (Co. Name) OR Owner COPY TO: Building Department HERS Provider (d applicable) Suilding Owner at Occupancy PAGE 2 F2001-01 (4-02) Action Now T-24CF64n1XTXV macro m a Certificate of Insulation Your home has been insulated with John Manville Fiberglass insulation products, which are designed m for today's safety standards and tomorrow's energy requirements. N .4 Fiberglass is inorganic and therefore permanently noncombustible, so It does not have to be treated U) with fire -retardant chemicals that will likely lose their effectiveness over time. It has not been treated mwith chemicals that can corrode wiring or metal. Fiberglass will not absorb moisture nor will it N settle over time as may other insulation materials. V4 0 y Or c 0 y ti 0 ti m N N m m m r` This also certifies that insulation have been professionally installed in this home to provide the following thermal performance. Lennar Homes Job Name: Tapestry Q Esplanade Tract: 29323 Plan# 113 Phase: Lot No: 28 Job Address: SFR - 79-907 Castillo Dr, La Qufnta, CA Ceiling Area: R-38 batt insulation Garage Ceiling: Non -Access: VYith Living Above & Sloping Anus Exterior Wail* R-13 batt Insulation Between Floors: Overhangs: Access Attic: With Living Above Interior Walls: Subcontractor...0 J Insulation, Inc. 72-227 Adelaid St, Thousand Palms, CA 92276 Mike Dickerson, General Manager - Palm Springs Division R -means resistance to heat flow. The higher the R -value, the greater the insulating power. Ask your bullder for the fact sheet on R -values. Keep this certificate with your other valued papers. If you ever sell this home, this certificate should be passed on to the buyer. 14