Loading...
12-0605 (AR)W. P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: r12-00000605 Property Address: 80745 CEDAR CREST APN: 762-060-016- - - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 29659 Iii j - IZWEf"Li Vifl_sff Architect or Engineer: �I P - - - - - - - - - - - - - - - - - - LICENSED CONTRACTOR'S DECLARATION BUILDING & SAFETY DEPARTMENT BUILDING PERMIT I hereby affirm under penalty of perjury that I m licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the 8 ss dePssionals Code, and my License is in full force and effect. Lice �gepC�ss: yB� License No.:_ 684857 ate: r I L.- ntractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did riot build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(sl licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason - Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 7/18/12 Owner: PHIL LACHAMBRE 80745 CEDAR CREST LA QUINTA, CA 92253 MBOB Contractor:EDWARDS CONSTRUCTION51455 DESERT CLUB DRLA QUINTA, CA 92253(760)777-8202 LiC. No.: 684857 ------------------------7---------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is v issued. 1� I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier GRANITE STATE Policy Number WC1914223 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as tobecome subject to the workers' compensation laws of California, and agree that, if I sh be me su j t to the workers' compensation provisions of Section 3700 of the Labor -od I s II f comply with those provisions. 1 te:� �� Z- pplicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree t comply with all city and unty ordinances and state laws relating to bui ng ons cti reby authorize presentatives of this�cl my enter Don the above-mentioned prop fo i sp t' n r I ate. ` Signature (Applicant or Agent): a% Application Number . . . . 12-00000605 Structure Information 359SF CASITA/VB/RES-3/CLASS A --FR [ENG] Other struct info . . . . . CODE EDITION 2010 # BEDROOMS 1.00 FLOOD ZONE NO PATIO ,SQ FTG 49.00 ---------------------------------------------------------------------------- IST FLOOR SQUARE FOOTAGE 359.00 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 284.50 Plan Check Fee'. 184.93 Issue Date . . . . Valuation . . . . 29659 Expiration Date .. 1/14/13 Qty Unit Charge Per Extension BASE FEE 252.00 5.00 6.5000 ---------------------------------- THOU BLDG 25,001-50,000 ------------------------------------------ 32.50 Permit ELECT - ADD/ALT/REM Additional desc . Permit Fee . . 27.57 Plan Check Fee 6.89 .Issue Date Valuation . . . . 0 Expiration Date 1/14/13 Qty Unit Charge Per Extension BASE FEE 15.00 359.00 .0350 --------------------------------------------------------------------,-------- ELEC NEW RES - 1 OR 2 FAMILY 12.57 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 46.00 Plan Check Fee 11.50 Issue Date . . . . Valuation . . . . 0 Expiration Date 1/14/13 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00' 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 2.00 6.5000 ------------------------------------------------------ EA MECH VENT FAN w 13.00 PLUMBING Additional desc . Permit Fee . . 58.50 Issue Date LQPERMIT Plan Check Fee Valuation . . 5 14.63 0 Application Number . . . . . 12-00000605 Permit . . . . . PLUMBING Expiration Date . 1/14/13 Qty Unit Charge Per Extension BASE FEE 15.00 5.00 6.0000 EA PLB FIXTURE 30.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 ---------------------------------------------------------------------------- Special Notes and Comments 359SF CASITA WITH ENTRY/VB/RES-3/CLASS A -FR [ENGINEERED) THIS PERMIT DOES NOT INCLUDE BLOCK WALLS, GATES, OR FLAT WORK. 2010 CALIFORNIA BUILDING CODES. July 18, 2012 1:17:16 PM AORTEGA --------------------------------------------------------- ------------------ Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 2.00 ENERGY REVIEW FEE 18.49 STRONG MOTION (SMI) - RES 2.97 Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 416.57 .00 .00 416.57 Plan Check Total 217.95 .00 .00 217.95 Other Fee Total 23.46 .00 .00 23.46 Grand Total 657.98 .00 .00 657.98 LQPERMIT 1b/MAY/'LUII/W1;U U4:5U FM Monarch Accounting May 14, 2012. Phil &.Cathy LaChambre 80-745 Cedar Crest La Qulnta, CA 92253 FAX No. IbU llb 5112 P. 001 PGA WEST H RESIDENTIALASSOCIA.TION, INC. 39755 BERKEY DRIVE STE A PALM DESERT, CA 92211 PHONE (760) 776-5100 • FAX (760) 776-5111 Reference: 80-745 Cedar Crest, La Quinta, CA Architectural Change Request— Casita, Gates, Pavers, Landscpe. Dear Phil & Cathy LaChambre: The Architectural and Landscape Committees for POGA WEST II Residential Association met on May 10, 2012 and reviewed and approved your architectural and landscape plans and approved with the following conditions being met. • All other Architectural Rules & Regulations of PGA WEST II Residential Association dated Revised 8/1/07 pertain. • A Maintenance Agreement will be required, one will be sent to you for proper execution as soon as it is prepared by counsel. •. Your contractor must meet with Bob Pantanella, Director of Community Services prior to commencing any work so they are aware of access, parking and other regulations of the Association, Mr. Pantanella's phone number is 760-564-1032. • All trees must be planted 5 feet from -the structures. • All plants must have one bubbler per plant. • The Bird of Paradise must be dwarf. . • All plants must 'be warrantied for 12 months from approval of Notice of Completion inspection. • Please note on the Architectural Casita plan there does not appear to be an A/C unit for the Casita. Review by the Committee is only for general conformance with the Architectural Rules, It is the responsibility of the owner to fu//y understand and conform to the Architectural Rules criteria whether or not all deficiencies are noted during review. It is also the owner's fu// resvonsibi/ity to fled verify a// existing conditions The Committee's decision with regard to project design will be final. Please refer to the Architectural Ru/es for a// reoulred submittals. Please contact Luis Umana, Sunshine Landscape at 760/346-3999 and Joanne Rose, the Association Manager, prior to any irrigation modifications associated with this change.. Damage to landscaping, i.e. shrubs, trees, flowers and turf is the responsibility of the contractor. The original landscaping must be brought back to its original condition when the project Is completed. Approvals given by the Architectural Committee are good for only six months from the date on the approval letter. If construction has not commenced within six months after a project approval date, a new application must be submitted. D ,/oNZ ey . 9 "O/? lb/MAY/ZUlZ/WEE U4:5U YM Monarch Accounting iAX No,'IbU T/b blIZ F. UUZ Page II PGA WEST II Residential Association Architectural/Landscape/LaChambre 5.14.12 Upon completion of your project, please complete and return The Notice of Completion of Architectural Change. For additional information or questions, the Board has directed that you contact Joanne Rose, CLAM, Association Manager, at 760/776-5100, Ext. 320. Sincerely, PGA WEST H Residential Association Joanne RoeseCCAM Manager for the Architectural Committee Cc: unit Arch a &toe..., '1.-�aWyaeow STRUCTURAL AND CIVIL ENGINEERING DENISE R. POELTLER, INC. 77725 Enfield Lane • Unit # 130 • Palm Desert, California 92211 drpfly@aol.com _ 26 June 2012 ' CITY OF LA QUINTA Department of Building and Safety _ 78-495 Calle Tampico La Quinta, CA 92253, RE: LA CHAMBRE CASITA Job Site Address: 80-745 Cedar -Crest, PGA West Subject: Truss Acceptance Letter Homeowners: Mr. and Mrs. Phil L4 Chambre , Dear Building Director: I have reviewed the total deflection-, live, dead, -and drag loads used for the design of the gang -nail roof trusses prepared by Imperial Truss and Lumbe�Co. (dated 6-26-2012), and found them in conformance with the structural documents prepared by my firm. Respectfully submitted, r No. 33448 Exp. 6-30,14 Denise R. Poeltler 9 c 1 IV R.C.E. 33446 W.O.42-138 cc: 'Mr. Robert A. Pitchford, PITCHFORD DESIGNS. PHONE.(760) 772-4411 0 FAX (760) 772-4409 Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 Project Name: Owner's Name: Phil Le Chambre This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMWIND. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 11620) Project Address: 80-745 Cedar Crest, La Quinta, CA 92254 Project Description: APN: 762-060-016 Type of Development:Residential XX Commercial otal Square Feet of Building Area: 359 Date: July 19, 2012 Phone No. Lot #'s: Industrial Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury d further represents that he/she is authoriz d to .sign on lielialf h caner/developer. 1'; 1 i j Dated: - Signature: `~J *************************************N1**-******************************* SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code Project Agreement Existing Not Subject to Fee 65995 Approval Prior to 1/1/87 Requirement 359 $3.20 $1148.80 Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by: Marcela Valdez, Construction Analyst Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT.OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) arit n notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest th position of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or perfoemance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This, Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good caosc, as determined by the School istrict, and no to three (3) such extensions may be granted. tt � `Il:; dnc; i p ec /:eI i?i.Iltc of '�rnripdiun::c f0 w:: Ilpthdod 3-:1.III? 11/2010 Bin # /p) l/ City of La Quinta Building 8z Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and ?racking Sheet Permit # Project Address: V— 74 6� Owner's Name: A. P. Number: 7b Z— U Address: —745 p Legal Description: City, ST, Zip•�% Contractor: Tele hone.P �;,. �`<:�::ka:::<z;;<;g<>:::<:'?;::#^:,�'• Address: �� CGt9�j Project Description: City, ST, Zip: lig-} 22'�3 ZDZ :...r.H.::.:..:.:::.•:,..:a;:..::.;;..;„:. i{itJi.:\\'•n.}: '.i ��ii:$YS?:<i.C�{i� LTelephone.: te Lic. : �/ D 8 5 City Lic. Designer: UbV7 Address: -7 -7 4 O'Z- 6� City, ST, Zip: Gam''` �'EX'Q17—{.j }`.iSY{�2�}:j:T:`}rv:.4}U�'ii�n:<,4 ](in}IYO• 6� 5b State Lic. #: ConsuTelephone. ction Type: Occupancy: Project ' air Demo J type circleone ): New Addn Alter Repair Name of Contact Person: Sq. Ft.:775 # Stories: 1 T# Units: Telephone # of Contact Person:'] Q 14 !i 40 0 Estimated Value of Project: e5oo APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Req'd Renta TRACKING PERMIT FEES Plan Sets -9 Plan Check submitted Item Amount Structural Caics. :9 Reviewed, ready for corrections 10 lan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Cales. Plans picked up LO Construction Flood plain plan Plans resubmitted i Mechanical Grading plan god Review, ready for correctio Issue Electrical Subcontactor List ` Called Contact Person I' ♦ ® Plumbing Grant Deed Pians picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- 'n1 Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person .I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees AV 6�14t11Aw— ft[614. pfe.. 7 BUILDING ENERGY ANALYSIS REPORT I PROJECT: Mr. & Mrs. Phil La Chambre 80-745 Cedar Crest Rancho Mirage, CA 92270 Project Designer: Robert A. Pitchford Design and Drafting 77-622 Country Club Dr. Suite O Palm Desert, Ca 92211 (760) 346-2856 Report Prepared by: Jon Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 o I,1.•0bo CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE 3 1,1SIUM BY Job Number: Date: 6/27/2012 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building El • This program developed by EnergySoft, LLC — www.energysoft.com. EnerovPro 5.1 by EnerovSoft User Number: 6712 RunCode: 2012-06-27713:55:35 ID: �H�d�;lU JUN 29 2012 has approval and is w W] mw�1 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 8 HVAC System Heating and Cooling Loads Summary 11 Room Load Summary 12 Room Heating Peak Loads 13 Room Cooling Peak Loads 14 EnergyPro 5.1 by EnergySoft Job Number. ID: User Number: 6712 • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Mr. & Mrs. Phil La Chambre Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 1612712012 Date Project Address 80-745 Cedar Crest Rancho Mirage California Energy Climate one' CA Climate Zone 15 Total Cond.'Floor Area 359 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. E3 Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity ( Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 359 Radiant Barrier New Wall Wood Framed R-21 671 New Slab Unheated Slab -on -Grade None 359 Perim = 82' New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Front (NE) 24.0 0.550 0.55 4.0 none Bug Screen New Front (NE) 24.0 0.550 0.55 none none Bug Screen New Left (SE) 44.0 0.550 0.55 none none Bug Screen New Rear (SW 12.0 0.550 0.55 none none Bug Screen New Right (NIM 25.0 0.550 0.55 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Fumace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number.- 6712 RunCode: 2012-06-27T13:55:35 ID: Page 3 of 14 C� PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Mr. & Mrs. Phil La Chambre Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family O Existing+ Addition/Alteration Date 6/27/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System HVAC must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw re uirements in Residential Appendix RA3.3 must be met. The Roof R-38 Roof(R.38.2x 14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix R44.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24APA518158CVX070 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC incorporates HERS verified Duct Leakage.. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. [—E-n—emvPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2012-06-27713:55:35 ID: Page 4 of 14 • • 0 PERFORMANCE CERTIFICATE: Residential Part 3 of 5) CF -1 R Project Name - Building Type m Single Family ❑ Addition Alone Date Mr. & Mrs. Phil La Chambre ❑ Multi Family ❑ Existing+ Addition/Alteration 6/27/2612 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 7.49 5.48 2.01 Space Cooling 101.93 92.67 9.26 Fans 22.18 30.69 -8.51 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 131.60 128.84 2.76 Percent Better Than Standard: 2.1% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (NE) 30 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (NE) 260 48 Fuel Available at Site: Natural Gas (SE) 140 44 Raised Floor Area: 0 (SM 260 12 Slab on Grade Area: 359 (NW) 140 25 Average Ceiling Height: 10.0 Roof 359 0 Fenestration Average U -Factor: 0.55 TOTAL: 129 Average SHGC: 0.55 Fenestration/CFA Ratio: 35.9% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 62 012 Address 77-085 Michigan Drive Name Jon Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 2004780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelo a seal' g require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Robert A. Pitchford Design and Drafting c^� 77-622 Country Club Dr. Suite 0 RobertPitch Address Name ord City/State/Zip Palm Desert, Ca 92211 Phone (760) 346-2856 - -- ' Signed License # Date EnemyPro 5.1 by EnemvSoft User Number: 6712 RunCode: 2012-06-27713:55:35 ID: Pa e 5 of 14 • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Mr. & Mrs. Phil La Chambre Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1612712012 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavit7yExterior Frame Interiorl Frame Azm Tilt I Status 4 Location/Comments Roof 359 0.026 R-38 0 20 New ' 4.2.1-A9 New Casita Wall 212 0.069 R-21 30 90 New 4.3.1-A6 New Casita Wall 96 0.069 R-21 120 90 New 4.3.1-A6 New Casita Wall 248 0.069 R-21 210 90 New 4.3.1-A6 New Casita Wall 115 0.069 R-21 300 90 New 4.3.1-A6 New Casita Slab 335 0.730 None 0 180 New 4.4.7-A1 New Casita Slab 24 0.730 None 0 180 New 4.4.7-A1 New Casita FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 24.0 0.550 Default 0.55 Default 30 New Double Non Metal Tinted New Casita 2 Window 16.0 0.550 Default 0.55 Default 30 New Double Non Metal Tinted New Casita 3 Window 8.0 0.550 Default 0.55 Default 30 New Double Non Metal Tinted New Casita 4 Window 24.0 0.550 Default 0.55 Default 120 New Double Non Metal Tinted New Casita 5 Window 20.0 0.550 Default 0.55 Default 120 New Double Non Metal Tinted New Casita 6 Window 4.0 0.550 Default 0.55 Default 210 New Double Non Metal Tinted New Casita 7 Window 4.0 0.550 Default 0.55 Default 210 New Double Non Metal Tinted New Casita 8 Window 4.0 0.550 Default 0.55 Default 210 New Double Non Metal Tinted New Casita 9 Window 25.0 0.550 Default 0.55 Default 300 New Double Non Metal Tinted New Casita (1) U -Factor Type: 116-A =Default Table from Standards, NFRC =Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade ape SHGC Hqt'l Wd Ove hang Left Fin Len Hclt LExt RExt Dist Len Ri ht Fin H t Dist Len H t 1 Bug Screen 0.76 8.01 3.0 4.0 0.1 4.0 4.0 2 Bug Screen 0.76 3 Bug Screen 0.76 4 IBug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 EnergyPro 5.1 by EnemvSoft User Number: 6712 RunCode: 2012-06-27713:55:35 ID: Page 6 of 14 • • • CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Mr. & Mrs. Phil La Chambre Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1612712012 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existi , rig Altered Removed Volume Year Built HVAC New Casita 359 3,590 Totals 1 3591 0 01 01 1 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Coolin q Type Min. Eff. Thermostat Type Status HVAC 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Coolin Duct Location R -Value Ducts Tested? Status HVAC Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New 0 WATER HEATING SYSTEMS S stem NameQ Type Distribution Rated Input Btuh Tank Cap. al Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status CEC Standard MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft c 0 i� N a System Name Pipe Len th Pipe Diameter Insul. Thick. O HP Plenum Outside Buried EneroyPro 5.1 by EnergySoft User Number., 6712 RunCode: 2012-06-27713:55:35 ID: Page 7 of 14 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Mr. & Mrs. Phil La Chambre Date 6/27/2012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of § 10-11 i (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent LI -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested labeled and installed according to ASTM Ell 677-95(2000) when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of 1 13 c 5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1506)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1506)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1506)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150-13. §1506)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(50(VA: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1506)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. §150(4)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-06-27T13:55.35 ID: Page 8 of 14 1� F, MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Mr. & Mrs. Phil La Chambre 1612712012 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building'cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 1 50 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat um or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. §150(p): Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150(p). Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall'contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). §1.50(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Op to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-06-27713:55:35 /D: Page 9 of 14 r_7 • • MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Mr. & Mrs. Phil La Chambre 1612712012 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with 150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148, OR not contain a screw -base socket, and consume no more than five watts of power.as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that thev are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number., 6712 RunCode: 2012-06-27713:55:35 ID: Page 10 of 14 L J HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Mr. & Mrs. Phil La Chambre Date 6/27/2012 System Name HVAC Floor Area 359 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 597 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Out ut perSystem 51,000 11,123 1,259 114 9,507 Total Output Btuh 51,000 0 Output Btuh/s ft 142.1 642 467 Cooling System 0 0 Output perSystem 17,800 0 0 0 0 Total Output Btuh 17,800 0 642 12,407 1.2591 0 Total Output ons 1.5 467 Total Output Btuh/s ft 49.6 Total Output s ft/Ton 242.0 10,442 Air System CFM perSystem 600 HVAC EOUIPMENT SELECTION Airflow cfm 600 Carrier 24APA518/58CVX070 12,455 1,961 51,000 Airflow cfm/s ft 1.67 Airflow cfm/Ton 404.5 Outside Air % 0.0% Total Adjusted System Output 12,455 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 1,961 1 51,000 Aug 3P MJan 1 AM Outside Air cfm/s ft 0.00 Note. values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 71 OF 71 OF 151 OF 151 OF 11 Heating Coil Supply Fan 600 cfm 150 F ROOM --;----------- ���❑ 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 71 / 59 OF 71/59°F 52/51°F 52/51°F Cooling Coil Supply Fan 53 ! 51 OF 600 cfm 51.3% ROOM 701 59 OF EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-06-27713:55:35 ID: Page 11 of 14 • • • ROOM LOAD SUMMARY Project Name Date Mr. & Mrs. Phil La Chambre 6/27/2012 System Name Floor Area HVAC 359 ROOM LOAD SUMMARY I I 1 ROOM COOLING PEAK I COIL COOLING PEAK I COIL HTG. PEAK Zone Name I Room Name Mult. I CFM I Sensible I Latent I CFM I Sensible I Latent I CFM I Sensible New Casita I New Casita 1 1 1 597 11,123 1',25-91 5971 11,1231 11259 114'1 9,507 PAGE TOTAL TOTAL 597 11,123 1,2591 114 9,507 597 11,123 1,259 114 9,507 Total includes ventilation load for zonal systems. EnergvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2012-06-27713:55.35 ID: Pa a 12 of 14 • • C. ROOM HEATING PEAK LOADS Project Name Date Mr. & Mrs. Phil La Chambre 6/27/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name New Casita Time of Peak Jan 1 AM Floor Area 359.0 ft' Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 72 OF Conduction Area U -Value AT aF Btu/hr R-38 Roof(R.38.2x 14.16) 359.0 X 0.0260 X 46 = 429 R-21 Wall (W.21.2x6.16) 671.0 X 0.0690 X 46 = 2,130 Double Non Metal Tinted 129.0 X 0.5500 X 46 = 3,264 Slab -On -Grade perm = 82.0 X 0.7300 X 46 = 2, 754 X X = X X = X X = X X = X X = X X = X X _ X X = X X - X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 8,576 Infiltration:[ 1.00 X 1.064 X 359 X 10.00 X 0.318 /60] X 46 = 931 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 9,507 Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2012-06-27713:55:35 ID: Page 13 of 14 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Mr. & Mrs. Phil La Chambre 1 6/27/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name New Casita Outdoor Dry Bulb Temperature 112 OF Floor Area 359.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temoerature 70 OF Outdoor Dailv Ranae: 34 OF Opaque Surfaces R-38 Roof(R.38.2x 14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6:16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Orientation (SE) (SIM Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = 359.0 0.0260 56.0 212.0 0.0690 27.0 96.0 0.0690 31.7 248.0 0.0690 29.3 115.0 0.0690 31.2 43.2 = 0.0 X 31.4 + 16.0 X 43.2 = 0.0 X 31.4 + Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window New Window New Window New Window New Window New Window New Window New Window New Window New Orientation (NE) I I (SE) I I (N►M I Shaded Unshaded Area GLF Area GLF 0.0 X 31.4 + 24.0 X 43.2 = 0.0 X 31.4 + 16.0 X 43.2 = 0.0 X 31.4 + 8.0 X 43.2 = 0.0 X 31.4 + 24.0 X 45.5 0.0 X 31.4 + 20.0 X 45.5 0.0 X 31.4 + 4.0 X 39.9 0.0 X 31.4 + 4.0 X 39.9 0.0 X 31.4 + 4.0 X 39.9 0.0 X1 31.4 +1 25.0 XI 54.1 c Page Total Btu/hr 523 395 210 502 247 1 1,037 691 346 1,091 909 160 160 160 1,352 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.94 X 19.64 X 42 = 821 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,1231 Latent Gain Btu/hr Occupants 77=4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.94 X 19.64 X 0.00523 = 459 Air Sensible CFM ELA AW FOR