11-0409 (AR)a P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 APrppli�n Number: 1.1-00000409 operty Address: 79530 CETRINO APN: 772 -330 -003 - Application description: ADDITION - RESIDENTIAL Property Zoning: ' LOW DENSITY RESIDENTIAL Application valuation: 25000 Tuyl 4 4 Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Applicant: Architect or Engineer: ��;7A amu/ . -V.�A. LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. cense Class: B License N .: 799359 Dater Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERA11T Owner: SOSEBEE JOYCE 79530 CETRINO LA QUINTA, CA 92253 Contractor: GILMOND'S CONSTR 1075 SAN JACINTO WA PALM SPRINGS, C 92 (760)320-9256 Lio. No.: 799359 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/26/11. MAY 9? WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code; for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND_ Policy Number' 1242547=2011 I certify that, in the performance of the work for which this permit is issued, 1 shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should b ome subject to the workers' compensation provisions of Section 3700 of the Labor Code, all forth ith Dmpl r ith' hose provisions. Date: «V Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. , APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 Each person upon whose behalf this application is made, each person at whose request and for whosebenefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives rlale:��nature ipon the above-mentioned property for i pec i.ourpo (Applicant or Agent): //� �j V - R Application Number . . . . . 11-00000409 LQPER\1IT Structure Information Construction Type . . . . . TYPE V, UNPROTECTED Occupancy Type . . . . . DWELLG/LODGING/CONG <=10 Other struct info CODE EDITION 2010 # BEDROOMS ..00 FLOOD ZONE NO ---------------------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 150.00 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 252.00 Plan Check Fee 163.80 Issue Date Valuation . . . . 25000 Expiration Date 11/22/11 Qty Unit Charge Per Extension BASE FEE 45.00 23.00 9.0000 -------------------------------------------- THOU BLDG 2,001-25,000 -------------------------------- 207.00 Permit ELECT - ADD/ALT/REM Additional desc . Permit Fee 30.75 Plan Check Fee 7.69' Issue Date . . . . Valuation . . . . 0 Expiration Date 11/22/11 Qty Unit Charge Per. Extension BASE FEE. 15.00 150.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 5.25 14.00 .7500 PER ELEC DEVICE/FIXTURE 1ST 20 10.50 -------------------------------------------=-------------------------------- Special Notes and Comments .150 SF ADDITION TO KITCHEN AND DINING AREA OF EXISTING SFD PER ENGINEERED PLANS. 2010 CODES. ---------=------------------------------------------------------------------ Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 1.00 ENERGY REVIEW.FEE 16.38 STRONG MOTION (SMI) --RES 2.50 Fee summary Charged Paid Credited Due --------------------------- Permit Fee Total ------------------------------ 282.75 .00 .00 282.75 Plan Check Total 171.49 .00 .00 171.49 Other Fee'Total 19.88 .00 .00 19.88 Grand Total 474.12 .00 .00 474.12 LQPER\1IT .Bin # Qty of La Quanta Building 6r Safety Division Permit # P.O. Box 1504, 78-495 Calle Tampico G La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Project 9T > ` , 0 d Owner's Name: A. P. Number: Address: 7d -1 �� C ✓� Legal Description: City, ST, Zip: aL 2 Z Z Contractor: )s / xa'•>aE:z?rY<As>,�> Telephone: C Address: SC Project Description: City, ST, Zip:t n S ( 2 / C (If Telephone: 760 State Lic. # : ] S City Lic. #< Arch., Engr., Designer: Address: City, ST, Zip: Telephone: P Construction T Occupancy: Type: P cy: State Lic. #: $: `wx :" _<x:s, . ;.c:u; 'ns . ;- y ;,,y t.•.lk t>.;;':..: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: n Ifild(Zop�T Sq. Ft.: is # Stories: # Units: Telephone # of Contact Person: 6p d ZS O 0 0 J P Estimated Value of Project: as, 00 L� APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready foro rections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Caics. Plans picked up 110 Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2"' Review, ready for correction issue S Electrical Subcontactor List Called Contact Person . f Z Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval ek)1 Plans resubmitted Grading IN HOUSE:- ''' Review, ready for coerectionstissuc Developer Impact Fee. Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees ✓ b j . f Z - Total Permit Fees Date 5/12/11 No. 30989 Owner Joyce Sosebee Address 79530 Cetrino City La Quinta Zip Tract # Type Residential Addition CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 Q BERMUDA DUNES r RANCHO MIRAGE INDIAN WELLS PALM DESERT ,y LA QUINTA 11 I1 0 DO y) 0 APN # 776-250-003 Jurisdiction La Quinta Permit # No. of Units 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 79530 Cetrino 150 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 150 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Daniel Gilmond Check No. Name on the check Telephone Funding Exempt By Dr. Sharon P. McGehee _ ... Superintendent Fee collected /exem ted by ,� n M Gilvrey Payment Recd J — • (3�ier/Under, Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this W serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting nt A O ig w 0,� r40 N°' �b -P ,A v i � 184.91- Aoll wo o � do � w Riverside, GA, 2011-2012- 776-250-003 (AIt:116-2bU-UU3), tUb3U Lot I KINU, IA UUIN I A, UN UZZ03-0080, oneet: i or , O... q T �SrgFET �y 1 SN d?p oN 164.06 N a% N 136.98 o� V °1 0o Op E7 - �JOVEN ENGINEERING GS t r u c t u r a l E n g i n e e r i n g T; P.O. Box 5098 La Quinta, CA 92248-5098 (760) 408-6441 May 11, 2011 City of La Quinta Building & Safety Department 78-495 Calle Tampico La Quinta, CA 92253-1504 Attn. Department of Building and Safety Ref: Sosebee Residence Addition 79-350 Cetrino La Quinta, CA Plan Check No. 11-1409 Subject: Roof Truss Calcs Dear Sirs, Job No. 11-6002 n CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DAT 2 ' By -Z;W We have been provided with Truss Calculations package provided by Spates Fabricators to be used for referenced project. We have reviewed Truss layout and Calculations and find them to be in general agreement with the design intent for this project. If you have further questions, please feel free to call. Sincerely, Joven Engin eying J seph R. Venuti, C.E. 41210 C JOVFN JOBS 2011 Ani TR[jSSR-1 XVPO BUILDING ENERGY ANALYSIS REPORT PROJECT: Sosebee Residence 79530 Citrino La Quinta, CA Project Designer: 11 CITY OF LA QUINTA BUILDING& SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE By I Report Prepared by: Joan D. Hacker Insu-form, Inc. 77-810 Las Montanas Road, Suite 201 „ Palm Desert, Ca 92211 .4 ©FfLCIEE. 760-345-1352 Job Number: P2-ECF-,1VMD APR 2 2 2011 Date: BY: 4/13/2011 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED. FOR CONSTRUCTION DAT 5 2-4 ?�llgy K • The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. 5.1 by EnergySoft User TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary' EnergyPro 5.1 by EnergySoft Job Number. ID: User Number 2655 1 2 3 10 13 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Sosebee Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 4/13/2011 Project Address 79530 Citrin La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,966 Addition 150 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes El No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes 0 No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavi Features see Part 2 of 5 Status Slab Unheated Slab-on-Grade None 2,816 Perim = 53' Existing Wall Wood Framed R-13 653 Existing Door Opaque Door None 20 Existing Roof Wood Framed Attic R-22 2,816 Existing Wall Wood Framed R-13 381 New Slab Unheated Slab-on-Grade None 150 Perim = 15' New Roof Wood Framed Attic R-38 150 New FENESTRATION Orientation Area(ft) U- Exterior Factor SHGC Overhang Sidefins Shades Status Front (S) 64.0 0.710 0.73 2.0 none Bug Speen Existing Front (S) 12.0 0.710 0.73 2.0 none Bug Speen Existing Left (169 28.0 0.710 0.73 2.0 none Bug Speen Existing Left (W) 63.0 0.710 0.73 2.0 none Bug Speen Existing Left (IM 21.0 0.710 0.73 2.0 none Bug Screen Existing Rear (N) 21.0 0.710 0.73 2.0 none Bug Speen Existing Rear (N) 35.0 0.710 0.73 2.0 none Bug Speen Existing Rear (N) 113.0 0.710 a 73 4.0 none Bug Speen Existing Rear (IN) 21.0 0.710 0.73 2.0 none Bug Speen Existing Rear (N) 21.0 0.710 0.73 2.0 none Bug Speen Existing Right (E) 42.0 0.710 0.73 2.0 none Bug Speen Existing HVAC SYSTEMS Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78016 AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Type Gallons Min. Eff Distribution Status Ene Pro 5.1 by Ene Soft User Number. 2655 RunCode: 2011-04-13T15:47:35 ID: Page 3 of 13 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Sosebee Residence Building Type ® Single Family O Addition Alone El Multi Family ® Existing+ Addition/Alteration 1411312011 Date Project Address 79530 Citrino La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,966 Addition 150 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes El No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavi Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Right (E) 6.0 0.710 0.73 2.0 none Bug Screen Existing Right (E) 28.0 0.710 0.73 2.0 none Bug Screen Existing Right (E) 42.0 0.710 0.73 2.0 none Bug Sheen Existing Front (S) 12.0 0.590 0.38 2.0 none Bug Screen New Left (W) 12.'0 0.590 0.38 2.0 none Bug Screen New Left (119 17.5 0.590 0.38 2.0 none Bug Speen New Left (169 17.5 0.590 0.38 2.0 none Bug Speen New HVAC SYSTEMS Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status WATER HEATING Type Gallons Min. Eff Distribution Status Ene ro 5.1 by EnergySoft User Number. 2655 RunCode: 2011-04-13T15:47:35 ID: Page 4 of 13 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF-1 R Project Name Building Type m Single Family O Addition Alone Date Sosebee Residence 1 t7 Multi Family m Existing+ Addition/Alteration 4/13/2011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 5.18 4.80 0.38 Space Cooling 122.62 122.95 -0.33 Fans 26.60 26.62 -0.02 Domestic Hot Water 13.78 13.78 0.00 Pumps 0.00 0.00 0.00 Totals 168.18 168.15 0.03 Percent Better Than Standard: ao % BUILDING COMPLIES -NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (S) 180 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 320 88 Fuel Available at Site: Natural Gas (KI 550 159 Raised Floor Area: o (N) 450 211 Slab on Grade Area: 2,966 (E) 310 118 Average Ceiling Height: 8.9 Roof 2,966 0 Fenestration Average U-Factor: 0.70 TOTAL: 576 Average SHGC: 0.69 Fenestration/CFA Ratio: 19.4% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Insu-form, Inc. M132011 Address 77-810 Las Montanas Road, Suite 201 Name Joan D. Hacker City/State/ZipCity/State/Zip Palm Desert Ca 92211 Phone 760-345-1352 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business. & Professions Code) Company Address Name City/State/Zip . Phone, Signed License # Date EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2011-04-13T15:47:35 ID: Page 6 of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Sosebee Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Afteration Date 4/13/2011 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cav'y Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Slab 2,816 0.730 None 0 180 Existing 4.4.7A1 Existing Living Wall 124 0.102 R-13 180 90 Existing 4.3.1 A3 Existing Living Door '20 1.450 None 180 90 Existing 4.5.1 A 1 Existing Lwin Wall 198 0.102 R-13 1 270 90 1 Existing 4.3.1 A3 Existing Living Wall 139 0.102 R-13 0 90 Existin 4.3.1 A3 Existing Lwin Wall 192 0.102 R-13 90 90 Existin 4.3.1 A3 Existing Living Roof 2,816 0.043 R-22 180 0 Existing 4.2.1-A6 Existing Living Wall 385 0.102 R-13 90 90 Remove 4.3.1-A3 Existing Lwin Wall 881 0.102 R-13 180 90 New 4.3.1 A3 Addition Slab 150 0.730 None 0 180 New 4.4.7-A 1 Addition Wall 193 0.102 R-13 270 90 New 4.3.1-A3 Addition Wall 100 0.102 R-13 0 90 New 4.3.1 A3 Addition Roof 150 0.025 R-38 180 0 New 4.2.1-A21 Addition FENESTRATION SURFACE DETAILS . ID Type Area U -Factor SHGCz Azm Status Glazing Type Location/Comments 1 Window 64.0 0. 7101 Default 0.73 1 Default 180 Existing Double Metal Clear Existing Living 2 Window 12.0 0.710 Default 0.73 Default 180 Existing Double Metal Clear Existing Living 3 Window 12.0 0.710 Default 0.73 Default 270 Removed Double Metal Clear Existing Living 4 Window 28.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 5 lWadow 63.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 6 Window 21.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 7 Window 21.0 0.710 Default 0.73 Default 0 Existing Double Metal Clear Existing Living 8 Window 35.0 0.710 Default 0.73 Default 0 Existing Double Metal Clear Existing Living 9 Window 49.0 0.710 Default 0.73 Default 0 Existing Double Metal Clear Existing Living 10 Window 64.0 0.710 Default 0.73 Default 0 Existing Double Metal Clear Existing Living 11 Window 21.0 0.710 Default 0.73 Default 0 Existing Double Metal Clear Existing Living 12 Window 21.0 0.710 Default 0.73 Default 0 Existing Double Metal Clear Existing Living 13 Window 42.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Existing Living 14 Window 6.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Existing Living 15 Window 28.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Existing Living 16 Window 42.0 0.710 Default 0.73 Default 1 901 Existing I Double Metal Clear Existing Living (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC T 116-B = Defauft Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t I Wd Ove ang Left Fin Len H t LEA I RExt Dist I Len Hgt Right Fn Dist Len Hgt 1 Bug Screen 0.76 8.01 8.0 2.0 0.1 2.01 2.0 2 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 3.0 4.0 2.0 0.1 2.0 2.0 4 lBug Screen 0.76 7.0 4.0 .2.0 0.1 2.0 2.0 5 JBug Screen 0.76 7.0 3.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 7.0 3.0 2.0 0.1 2.0 2.0 7 Bug Screen 0.76 7.0 3.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 7.0 5.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 `7:0 7.0 4.0 0.1 4.0 4.0 10 Bug Screen 0.76 8.0 a 0 4.0 0.1 4.0 4.0 11 Bug Screen 0.76 7.0 3.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 7.0 3.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 7.0 3.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 3.0 2.0 2.0 0.1 2.0 2.0 15 Bug Screen 0.76 7.0 4.0 2.0 0.1 2.0 2.0 16 Bug Screen 0.76 7.0 3.0 2.0 1 0.1 2.01 2.0 EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2011-04-13715:47:35 ID: Page 7 of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Sosebee Residence Building Type ® Single Family 13 Addition Alone 0 Mufti Family ® Existing+ Addition/Alteration Date 4/13/2011 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame I Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 12.0 0.590 NFRC 0.38 NFRC 180 New IWC 62001Low-E Addition 18 Window 12.0 0.590 NFRC 0.38 NFRC 270 New IWC 6200/Low--E Addition 19 Window 17.5 0.590 NFRC 0.38 NFRC 270 New IWC 62001Low--E Addition 20 Window 17.5 0.590 NFRC 0.38 NFRC 270 New IWC 6200 /Low -E Addition (1) U -Factor Type: 2 SHGC T 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window Ove ang Left Fn R cqi ht Fin SHGC Hgt Wd Len Hat LExt REM Dist Len Hgt Dist Len H t 17 Bug Screen 0.76 7.0 2.5 2.0 0.1 2.0 2.0 18 Bug Screen 0.76 7.0 2.5 2.0 0.1 2.0 2.0 19 Bug Screen 0.76 70 2.5 2.0 0.1 2.0 2.0 20 Bug Screen 0.76 7.0 251 2.0 0.1 2.0 2.0 EnergyPro 5.1 by EnergySoft User Number. 2655 Ru Code: 2011-04-13715:47:35 ID: Pa e 8 of 13 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Sosebee Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration 1411312011 Date BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Aftered I Removed Volume Year Built Living Zone Existing Living Z816 25,344 1979 Addition 150 1,200 Totals 1501 Z8161 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Living Zone 1 Central Fumace 78-/ AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing ❑ WATER HEATING SYSTEMS S stem Name Oty. Type Distribution Rated Input Btuh Tank Cap. al Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas No Pipe Insulation 40,000 50 0.53 n1a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 0 id N a System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried 01 1 ❑ Ene Pro 5.1 by EnergySoft User Number. 2655 RunCode: 2011-"13T15:47:35 ID: Page 9 of 13 MANDATORY MEASURES SUMMARY: Residential Pae 1 of3) MF -1R Project Name Sosebee Residence 1411312011 Date NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§ 150(a): Minimum R-19 insulation in wood -frame ceiling or equivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall or equivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor or equivalent U -factor. 150 : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 permAnch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building,are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1 500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1506)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1506)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-6. §1506)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1506)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(50(03A: Insulation is protected from damage, including that due to sunlight moisture, equipment maintenance, and wind. §1506)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. §150(0)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2011-04-13T15:47:35 ID: Page 10 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1R Project Name Date Sosebee Residence 1411312011 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire as specified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined as specified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a fine -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150 . 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode. 2011-04-13715:47:35 /D: Page 11 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -IR Project Name Date Sosebee Residence 1411312011 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (FMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exception"! to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130,131, 134 and 146. §150(k)16: Permanerrtly installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2011-04-13T15.47.35 /D: Page 12 of 13 'HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Sosebee Residence Date 4/13/2011 System Name Living Zone Floor Area 2,966 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK CFM Sensible Total Room Loads 1,653 53,090 Return Vented Lighting 0 Return Air Ducts 4,502 Return Fan 01 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 4.502 TOTAL SYSTEM LOAD 62,093 COIL HTG. Latent CFM 3,696 796 0 0 3,696 PEAK Heating System Sensible Output perSystem 70.000 39,461 Total Ou ut Btuh) 70,000 Output Stuh! 23.6 2,804 Cooling System 0 Output per System 58,000 0 Total Output Btuh 58,000 0 Total Output (Tons 4.8 2,804 Total Output Btuh! 19.6 Total Output s ft/Ton 613.7 45,068 Air System CFM per System 1,300 HVAC EQUIPMENT SELECTION Airflow cfrn 1,300 Existing HVAC 47,297 0 70,000 70,000 Jan 1 AM Airflow cfrW 0.44 Airflow cfm/Ton) 269.0 Outside Air % 0.0% Total Adjusted System Output 47,2971 Gusted for Peak Design conditions) TIME OF SYSTEM PEAK 0 Aug 3 PM Outside Air cf n/ ft 0.00 I Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF Outside Air 0 dirt Supply Fan 1,300 cfm 68 OF 68 OF 119 OF I Heating Coil 4 U:I=fl .4I 117 OF .ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooll Peak) 112/78°F 80/60°F 80/60°F 46/44°F Outside Air Ar= 0 c fm Supply Fan Cooling Coil 1,300 cfin 31.0 °i° 80 160 OF { 48 ! 45 OF , . ; ROOM 1 78 / 59 OF EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2011-04-13715:47:35 ID: Page 13 of 13